Page 1: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

SmartStack Reference Archi tec tures

Nimble Storage SmartStackTM

Desktop and Server Virtualization with Cisco and VMware

Combining both Desktop Virtualization and Virtualized Business Critical Applications

on a single converged infrastructure.

Page 2: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2

Table of Contents

REFERENCE ARCHITECTURES .................................................................................................................................................... 5

SUMMARY OF MAIN FINDINGS ................................................................................................................................................ 6

BUSINESS VALUE ...................................................................................................................................................................... 6

SOLUTION OVERVIEW .............................................................................................................................................................. 7

UNIFIED, PRETESTED, AND VALIDATED INFRASTRUCTURE ........................................................................................ 7

BENEFITS ................................................................................................................................................................................ 11

ARCHITECTURE AND DESIGN .................................................................................................................................................. 12

VMWARE VSPHERE, CISCO UCS, NIMBLE STORAGE ............................................................................................ 12 VIRTUALIZING BUSINESS CRITICAL APPLICATIONS ................................................................................................. 13

Availability ..................................................................................................................................................... 13 Performance Optimization ............................................................................................................................ 17 Data Protection ............................................................................................................................................. 22 Operational Management ............................................................................................................................. 24

MODULAR VIRTUAL DESKTOP INFRASTRUCTURE ................................................................................................... 32 Cisco UCS B-Series Blade Servers .............................................................................................................. 33 VMware vSphere .......................................................................................................................................... 33 VMware Horizon View .................................................................................................................................. 34 VMware View Planner .................................................................................................................................. 34 Nimble Storage CS-Series ........................................................................................................................... 34

SOLUTION VALIDATION .......................................................................................................................................................... 35

Server: Cisco UCS ........................................................................................................................................ 35 Storage: Nimble Storage CS-Series ............................................................................................................. 38 VDI: VMware ................................................................................................................................................. 39

TESTING METHODOLOGIES .................................................................................................................................................... 40

CONCLUSION .......................................................................................................................................................................... 43

APPENDIX A: BILL OF MATERIALS ........................................................................................................................................... 44

APPENDIX B: VALIDATION FOR 500-USER BUSINESS CRITICAL APPLICATIONS ENVIRONMENT ............................................ 45

RESOURCE UTILIZATION ...................................................................................................................................... 49

APPENDIX C: STORAGE PERFORMANCE ................................................................................................................................. 54

BOOT STORMS .................................................................................................................................................... 54 STEADY STATE .................................................................................................................................................... 54

APPENDIX D: HORIZON VIEW POOL DETAILS ......................................................................................................................... 56

APPENDIX E: VDI PLANNING AND SIZING QUESTIONS ........................................................................................................... 58

Page 3: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3

List of Figures

FIGURE 1 - CONVERGED INFRASTRUCTURE REFERENCE ARCHITECTURE ................................................................. 5 FIGURE 2 - HIGH LEVEL PHYSICAL TOPOLOGY ...................................................................................................... 12 FIGURE 3 - HIGH LEVEL LOGICAL TOPOLOGY ........................................................................................................ 13 FIGURE 4 - UCS AVAILABILITY – KEY POINTS ....................................................................................................... 14 FIGURE 5 - REDUNDANT NETWORKS .................................................................................................................... 14 FIGURE 6 - AUTOMATED NETWORK FAILOVER ....................................................................................................... 15 FIGURE 7 – STORAGE MPIO – ROUND ROBIN PATH SELECTION ............................................................................ 15 FIGURE 8 – ESXI STORAGE DEVICE SETTINGS ..................................................................................................... 16 FIGURE 9 - HYPERVISOR HA ................................................................................................................................ 16 FIGURE 10 - VIRTUAL NETWORK SEPARATION ...................................................................................................... 17 FIGURE 11 - OPTIMIZATION LOCATIONS ................................................................................................................ 17 FIGURE 12 - ISCSI STORAGE SUBNETS................................................................................................................ 18 FIGURE 13 – INFRASTRUCTURE SPECIFIC VOLUME ASSIGNEMNT ........................................................................... 18 FIGURE 14 - APPLICATION SPECIFIC VOLUME ASSIGNMENT ................................................................................... 19 FIGURE 15 - APPLICATION AWARE PERFORMANCE POLICIES ................................................................................. 19 FIGURE 16 - VMKERNEL NETWORK ALLOCATION - VSWITCH ................................................................................... 20 FIGURE 17 - VMKERNEL NETWORK ALLOCATION - DETAILS .................................................................................... 20 FIGURE 18 - VM PROPERTIES - EXCHANGE .......................................................................................................... 21 FIGURE 19 - VM PROPERTIES - SQL SERVER ....................................................................................................... 21 FIGURE 20 - VM PROPERTIES - SHAREPOINT ....................................................................................................... 22 FIGURE 21 - BACKUP UCSM ............................................................................................................................... 23 FIGURE 22 - NIMBLE VOLUME COLLECTION PROTECTION SCHEME ......................................................................... 24 FIGURE 23 - NIMBLE STORAGE SNAPSHOT SYNCHRONIZATION - EXCHANGE .......................................................... 24 FIGURE 24 - NIMBLE STORAGE SNAPSHOT SYNCHRONIZATION - SQL SERVER ....................................................... 24 FIGURE 25 - UCS VNIC ALLOCATION ................................................................................................................... 25 FIGURE 26 - ISCSI BOOT FROM NIMBLE ............................................................................................................... 26 FIGURE 27 - VCENTER STORAGE INTEGRATION ..................................................................................................... 26 FIGURE 28 - VCENTER OPERATIONS MANAGER .................................................................................................... 27 FIGURE 29 - VCOPS - APPLICATIONS .................................................................................................................... 27 FIGURE 30 - VCOPS HEALTH ............................................................................................................................... 28 FIGURE 31 - INFOSIGHT WELLNESS OVERVIEW..................................................................................................... 28 FIGURE 32 - INFOSIGHT CAPACITY USAGE............................................................................................................ 29 FIGURE 33 - INFOSIGHT PERFORMANCE VIEW ...................................................................................................... 30 FIGURE 34 - INFOSIGHT PROTECTION COVERAGE VIEW ........................................................................................ 31 FIGURE 35 - INFOSIGHT EXECUTIVE DASHBOARD ................................................................................................. 32 FIGURE 36 – UCS FABRIC INTERCONNECT – APPLIANCE PORT VLAN CONNECTIVITY ............................................ 35 FIGURE 37 - UCS APPLIANCE PORT CONFIGURATION ........................................................................................... 36 FIGURE 38 - CISCO UCS BLADE SERVER VNIC CONFIGURATION .......................................................................... 36 FIGURE 39 - VMWARE NETWORK CONFIGURATION ............................................................................................... 37 FIGURE 40 - VMWARE ISCSI PORT 1 CONFIGURATION DETAILS ............................................................................ 37 FIGURE 41 - VMWARE ISCSI PORT 2 CONFIGURATION DETAILS ............................................................................ 38 FIGURE 42 - VMWARE DESKTOP VIRTUAL MACHINE NETWORK CONFIGURATION DETAILS ...................................... 38 FIGURE 43 - NIMBLE STORAGE ISCSI INITIATOR SETUP ........................................................................................ 39 FIGURE 44 - NIMBLE STORAGE VOLUME MANAGEMENT ......................................................................................... 39 FIGURE 45 - VDI CLUSTER CONFIGURATION – VCENTER ORGANIZATION ............................................................... 40 FIGURE 46 - VMWARE VIEW PLANNER WORKLOAD AND RUN PROFILE ................................................................... 41 FIGURE 47 - NIMBLE STORAGE PERFORMANCE - DAY VIEW ................................................................................... 42 FIGURE 48 - CISCO UCS BLADE - STEADY STATE WORKLOAD - CPU UTILIZATION ................................................. 43 FIGURE 49 - BUSINESS CRITICAL APPLICATIONS ................................................................................................... 45 FIGURE 50 - EXCHANGE 2010 ARCHITECTURE ...................................................................................................... 45 FIGURE 51 - EXCHANGE 2010 DETAILED SETUP ................................................................................................... 46 FIGURE 52 - SQL AND SHAREPOINT DATABASE ARCHITECTURE ............................................................................ 46 FIGURE 53 – EXCHANGE LOADGEN RESULTS ....................................................................................................... 48 FIGURE 54 - DVDSTORE RUN RESULTS ............................................................................................................... 48 FIGURE 55 - EXAMPLE SHAREPOINT PAGE 1 ........................................................................................................ 49

Page 4: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4

FIGURE 56 - EXAMPLE SHAREPOINT PAGE 2 ........................................................................................................ 49 FIGURE 57 - ESXI SERVER 1 RESOURCE UTILIZATION .......................................................................................... 50 FIGURE 58 - ESXI SERVER 2 RESOURCE UTILIZATION .......................................................................................... 50 FIGURE 59 - EXCHANGE DAG NODE 1 RESOURCE UTILIZATION ............................................................................. 51 FIGURE 60 - EXCHANGE DAG NODE 2 RESOURCE UTILIZATION ............................................................................. 51 FIGURE 61 - SQL DB SERVING DVDSTORE AND SHAREPOINT DATABASES RESOURCE UTILIZATION ....................... 52 FIGURE 62 - NIMBLE STORAGE CS220G ARRAY IOPS AND LATENCY CHART ......................................................... 52 FIGURE 63 - BOOT STORM STORAGE PERFORMANCE............................................................................................ 54 FIGURE 64 – COMBINED WORKING DAY STORAGE PERFORMANCE ........................................................................ 55 FIGURE 65 - VMWARE HORIZON VIEW POOL CONFIGURATION ............................................................................... 56 FIGURE 66 - VIEW POOL STORAGE CONFIGURATION – POOL 1 .............................................................................. 56 FIGURE 67 - VIEW POOL STORAGE CONFIGURATION - POOL 2 ............................................................................... 57 FIGURE 68 - VMWARE HORIZON VIEW ADVANCED STORAGE SETTINGS ................................................................. 57

Page 5: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5

Reference Architectures

This document describes the Nimble Storage SmartStackTM reference architecture for virtual

desktop infrastructure (VDI) based on VMware Horizon View and virtualized business critical

applications (BCA) from Microsoft, including Exchange, SQL Server and SharePoint. VMware

vSphere serves as the hypervisor for both VDI as well as the business critical applications. The

hardware solution includes Cisco UCS® B-Series Blade Servers and Nimble Storage CS-Series

storage appliance.

This document will highlight design best practices for virtualizing business-critical applications on

SmartStack, and showcase what was validated jointly by Nimble Storage, VMware, and Cisco. If

you want to learn more about Nimble Storage SmartStackTM, please contact your sales

representative or visit our website for links to more resources.

The purpose of the reference architecture is to provide a tested and modular architecture built with

proven best-in-class technologies to create a complete server and desktop virtualization solution,

including the application and desktop software, hypervisor, computing, networking, and storage

elements. These reference architectures accelerate your IT datacenter transformation by

enabling faster deployments, greater efficiency, and lower risk.

Choosing the correct storage solution for your virtualization solution is a critical step, especially

when combining different workloads such as virtual desktop infrastructure (VDI) and virtualized

business applications. Through the use of partner provided tools such as VMware View Planner

and Microsoft specific load testing tools, we can provide more information about the actual running

of the solutions to help assess and plan the proper network and storage configuration for your

environments.

Using this approach, Nimble Storage has achieved a server application and desktop deployment

levels of 500 users on a single three-rack-unit (3RU) Nimble Storage flash optimized storage

system. This configuration is described in this document.

Figure 1 - Converged Infrastructure Reference Architecture

Page 6: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 6

This reference architecture is intended as a high level guide to understanding what was

configured and tested and is not intended to be a comprehensive guide to deployment and

configuration for every aspect of this or other possible solutions.

Summary of Main Findings

High density: the combination of the Cisco Unified Computing System™ (Cisco UCS)

and Nimble Storage hardware with VMware vSphere and VMware Horizon View software

produces a virtual desktop delivery system with a high density of users per blade and

chassis.

Workload consolidation: The converged infrastructure stack consisting of Cisco UCS

and Nimble Storage arrays eliminate the need for separate infrastructure silos for desktop

and server virtualization, simplifying deployment and management for the completely

virtualized datacenter.

Simplicity: Cisco maintains industry leadership with the new Cisco UCS Manager

software, which makes scaling and maintenance simple and helps ensure consistency.

Performance: The Cisco 10-Gbps unified fabric is also validated on second-generation

Cisco UCS 6200 Series Fabric Interconnects, testing more challenging workloads and

maintaining unsurpassed user response times.

Scalability: Up to 500 users virtual desktops and application support can run on an entry-

level Nimble Storage CS Series storage array.

Business Value

As organizations increasingly move to deploy server and desktop virtualization projects, they

often find that their IT infrastructure is incapable of adapting to the performance requirements that

virtualized business critical applications and desktop virtualization demand for meeting the needs

of the organizations. A well-designed, thoroughly tested server and desktop virtualization solution

can strategically empower a company to respond to the post-PC era, while simplifying

management and reducing cost by deploying these workloads on a single converged

infrastructure stack.

Companies require a scalable and highly available infrastructure on which to deploy their virtual

server and desktop environments. Several new technologies are available to assist them in

designing a virtual desktop solution, but they need to know how to use these technologies to get

the most from their investments, support service-level agreements (SLAs), and reduce their total

cost of ownership (TCO).

This solution builds an example of a common customer server and desktop virtualization

environment and validates the environment for performance, scalability, and capability.

Customers achieve:

Page 7: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 7

Increased control and security of their global, mobile desktop environment, which is

typically their most at-risk environment

Better end-user productivity with a more consistent environment

Simplified management, with the environment contained in the data center

Better support for SLAs and compliance initiatives

Lower operation and maintenance costs

Solution Overview

This solution uses Cisco UCS, Nimble Storage, and VMware vSphere to provide resources for a

virtual desktop infrastructure and virtualized business critical applications. The virtual desktop

infrastructure is built upon a VMware Horizon View environment of Microsoft Windows 7 virtual

desktops provisioned by VMware Horizon View Composer. The applications are built with

Microsoft specific application of Exchange, SQL Server and SharePoint.

Planning and designing the server, networking, and storage infrastructure for the VMware

environment is a critical step because the server infrastructure should be sized to handle both the

application and the desktop workload. This workload needs to address operations in terms of

density and scale. The infrastructure should be provisioned to handle the burst of data traffic, and

the shared storage must be able to absorb large bursts of I/O traffic that occur during a workday.

To provide a cost-effective and predictable performance for this type of virtualization

infrastructure, the solution must be able to:

Support a high density of virtual desktops per server

Scale linearly with increases in the number of virtual desktops

Support user workload on the selected applications

Provide low latency and high bandwidth for clustering, provisioning, and storage

interconnect networks

Handle the peak I/O load from clients while maintaining a quick response time

Unified, Pretested, and Validated Infrastructure

Cisco’s virtualization solution binds together the three critical elements of an end-to-end

deployment: the end-user, the network, and the data center. It draws on Cisco’s architectural

advantage to provide a solution that supports a diversity of endpoint devices, extends pervasive

security and policy management to each virtual desktop, and uses a new and innovative

virtualization-optimized stateless server computing model (Cisco UCS).

Base Components

The computing platform with Cisco UCS includes:

Page 8: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 8

o Cisco UCS 6200 Series Fabric Interconnects

o Cisco UCS 2200 Series Fabric Extenders

o Cisco UCS 5108 Blade Server Chassis

o Cisco UCS B-series Blade Servers for applications and virtual desktop hosting

Hypervisor: VMware vSphere

Virtual desktop connection broker: VMware Horizon View

Microsoft Business Critical Applications:

o Exchange

o SQL Server

o SharePoint

Storage platform with Nimble CS-Series

Cisco Unified Computing System

Cisco UCS is the first truly unified data center platform that combines industry-standard, x86-

architecture blade and rack servers with networking and storage access into a single system.

Innovations in the platform include a standards-based unified network fabric; Cisco virtualized

interface card (VIC) support, and Cisco Extended Memory Technology. The system uses a wire-

once architecture with a self-aware, self-integrating, intelligent infrastructure that eliminates the

time-consuming, manual, error-prone assembly of components into systems.

Cisco UCS B-Series Blade Servers provide a comprehensive line of 2 and 4-socket servers to

deliver world-record-setting performance to awide range of workloads. Based on Intel® Xeon®

processor E7 and E5 product families, these servers are excellent for virtualized and non-

virtualized applications. These servers:

Reduce CapEx and OpEx with converged network fabrics and integrated systems

management

Deliver performance, versatility, and density without compromise

Address a broad set of workloads, including IT and web infrastructure and distributed

databases, for both virtualized and non-virtualized environments

Increase IT staff productivity and business agility through just-in-time provisioning and

mobility support for both virtualized and non-virtualized environments

Cisco focuses on three main elements to deliver the best desktop virtualization data center

infrastructure: simplification, security, and scalability. The software in combination with platform

modularity provides a simplified, secure, and scalable desktop virtualization platform.

Simplified

o Virtual desktop density per sever

o Unified management, providing common view of the platform

o Predefined, validated infrastructure

Page 9: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 9

Secure

o Virtual desktop–aware access and control policies

o Virtual desktop–aware networking and on-demand provisioning

o Segmentation and network security policies across LAN and WAN

Scalable

o Capability to linearly scale up to thousands of desktops in a single domain

o Rapid desktop provisioning through service profiles

o Low-latency, high-bandwidth network for virtual desktop and multimedia delivery

The simplified, secure, scalable Cisco data center infrastructure solution for desktop virtualization

saves time and money. It provides faster payback and ongoing savings (better return on

investment [ROI] and lower TCO) with the industry’s highest virtual desktop density per server,

meaning that fewer servers are needed, reducing both capital expenditures (CapEx) and

operating expenses (OpEx). The solution also has much lower network infrastructure costs, with

fewer cables per server and fewer ports required, through the use of the Cisco UCS architecture

and unified fabric.

The simplified deployment of Cisco UCS for desktop virtualization accelerates time to productivity

and enhances business agility. IT staff and end users are more productive more quickly, and the

business can respond to new opportunities by simply deploying virtual desktops whenever and

wherever needed. The high-performance Cisco system and network deliver a near-native end-

user experience, allowing users to be productive anytime and anywhere.

VMware vSphere

VMware vSphere is the market-leading virtualization platform that is used in thousands of IT

environments around the world. VMware vSphere transforms a computer’s physical resources by

virtualizing the CPU, RAM, hard disk, and network controller. This transformation creates fully

functional virtual desktops that run isolated and encapsulated operating systems and applications

just like physical computers.

The high-availability features of VMware vSphere are coupled with VMware Distributed Resources

Scheduler (DRS) and vMotion, which enables the transparent migration of virtual desktops from

one VMware vSphere server to another with little or no impact on the customer’s use.

This reference architecture uses VMware vSphere Enterprise Plus edition for deploying desktop

virtualization. This provides the full range of features and functions of the VMware vSphere

allowing customers to achieve scalability, high availability, and optimal performance for all their

desktop workloads.

Horizon View

VMware Horizon View is a desktop virtualization solution that simplifies IT manageability and

control while delivering one of the highest-fidelity end-user experiences for devices and networks.

The VMware Horizon View solution helps IT departments automate desktop and application

Page 10: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 0

management, reduce costs, and increase data security through centralization of the desktop

environment. This centralization results in greater end-user freedom and increased control for IT

departments. By encapsulating the operating systems, applications, and user data into isolated

layers, IT departments can deliver a modern desktop. IT can then deliver dynamic, elastic

desktop cloud services such as applications, unified communications and 3D graphics for real-

world productivity and greater business agility.

Unlike other desktop virtualization products, VMware Horizon View is built on, and tightly

integrated with, VMware vSphere, the industry-leading virtualization platform, allowing customers

to extend the value of VMware infrastructure and its enterprise-class features such as high

availability, disaster recovery, and business continuity. VMware Horizon View includes many

enhancements to the end-user experience and IT control. Some of the notable features include:

VMware Horizon View Storage Accelerator (VSA): In memory host-based read cache that

reduces storage IO operations to the storage subsystem during Login/boot/AV storms.

VMware PCoIP Optimization Controls: Deliver protocol efficiency and enable IT

administrators to configure bandwidth settings by use case, user, or network

requirements and consume up to 75 percent less bandwidth

VMware PCoIP Continuity Services: Deliver a smooth end-user experience regardless of

network reliability by detecting interruptions and automatically reconnecting the session

VMware PCoIP Extension Services: Allow Microsoft Windows Management

Instrumentation (WMI)–based tools to collect more than 20 session statistics for

monitoring, trending, and troubleshooting end-user support problems

VMware Horizon View Media Services for 3D Graphics: Enable VMware Horizon View

desktops to run basic 3D applications such as Microsoft Windows Aero and Office 2010

or those requiring OpenGL or DirectX, without the need for specialized graphics cards or

client devices

VMware Horizon View Media Services for Integrated Unified Communications: integrate

voice over IP (VoIP) and the VMware Horizon View desktop experience for the end user

through an architecture that optimizes performance for both the desktop and unified

communications

VMware Horizon View Persona Management (VMware Horizon View Premier edition

only): Dynamically associates a user persona with stateless floating desktops; IT

administrators can deploy easier-to-manage stateless floating desktops to more use

cases while enabling user personalization to persist between sessions

VMware Horizon View Client for Android: Enables end users with Android-based tablets

to access VMware Horizon View virtual desktops

Support for VMware vSphere uses the latest functions of the leading cloud infrastructure platform

for highly available, scalable, and reliable desktop services.

Page 11: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 1

Nimble Storage CS-Series

Nimble Storage arrays are the industry’s first flash-optimized storage designed from the start to

increase efficiency. Built on the patented Cache Accelerated Sequential Layout (CASL)

architecture, Nimble Storage offers scalable performance, exceptional efficiency, integrated data

protection, and simple push-button management. As a result, customers can run more workloads

and perform more backup operations with less storage infrastructure and empower IT to take on

new projects with higher returns. CASL accelerates applications by using flash memory as a read

cache in conjunction with a write-optimized data layout. It protects data by supporting instant

snapshots for easy backup and restoration, along with efficient replication for disaster recovery.

Nimble Storage’s intuitive, automated tools greatly simplify storage and data management,

reducing operations overhead.

Nimble Storage delivers:

Accelerated performance for greater throughput and IOPS, and sub-millisecond latencies

Greater storage efficiency, reducing the storage footprint needed by 30 to 75 percent

Non-disruptive scaling to fit changing application needs through increased performance or

capacity, or both

Increased data and storage availability with integrated data protection and disaster

recovery

Simplified storage management and reduced day-to-day operation overhead

Benefits

High performance: Nimble Storage arrays with Cisco UCS deliver the adaptive

performance needed to handle comprehensive virtualization workloads delivered by

VMware Horizon View and Microsoft applications, in a compact footprint. This capability

allows IT to maintain a positive user experience through application use, boot and login

storms, patch operations, and updates.

Greater consolidation: VMware Horizon View frees IT departments from the chores of

desktop upgrades by centralizing the creation and deployment of linked clones. This

feature compliments Nimble Storage’s in-line compression and the dense computing and

I/O capabilities of Cisco UCS. IT departments that have deployed the joint platform have

seen 30 to 75 percent reduction in their storage footprint compared to traditional solutions,

with no degradation of the end-user experience.

High availability: Nimble Storage and Cisco UCS both incorporate redundant

components, with no single point of failure, along with proactive monitoring and reporting.

These features complement VMware vCenter’s capability to trigger efficient Nimble

Storage snapshots for instant backup and fast restore operations. The result is less end-

user disruption and fewer calls to the help desk.

Page 12: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 2

Expansion on demand: By integrating computing, fabric, storage, and virtualization

resources in a single architecture, IT can start small and independently scale horizontally

or vertically to large deployments supporting thousands of virtual desktops as needs

grow.

Architecture and Design

The converged infrastructure solution was built with Nimble Storage as the foundation and only

storage for the environment. The Cisco UCS servers and network were connected using only the

Fabric Interconnect methods. VMware vSphere provided the hypervisor platform. The details of

the solution are outlined below.

VMware vSphere, Cisco UCS, Nimble Storage

The following figure shows the basic components and connectivity used to for the server, storage,

and network. A single Nimble Storage array was connected to the Cisco UCS chassis through a

pair of Cisco UCS fabric interconnects using appliance ports. The VMware Infrastructure

components and the VMware Horizon View desktops were all run on the blades in Cisco UCS.

Figure 2 - High Level Physical Topology

Page 13: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 3

BCA Cluster

Business Critical Applications

Excha ng e

2010loa dg en

Sha rePoint

DB

Excha ng e

DB

Sha rePoint

2013

Horizon Cluster

125 Microsoft Windows7Desktops per

Cisco B-series balde

500 desktops

4 blades

...

Horizon View Desktops

VMware View Infrastructure

AD/DN S/

DH CP

Virtual

Center

View

Composer

View

Connect

View

Pla nnerM S KM S

M S S QL

vCO ps

Figure 3 - High Level Logical Topology

Virtualizing Business Critical Applications

When virtualizing business critical applications, there are four key areas we will want to address.

They are:

Availability

Performance

Data Protection

Operational Management

These will be addressed in the remainder of this section.

Availability

When you virtualize business critical applications, you want to ensure the entire infrastructure has

no single point of failure, for both hardware and software, across all layers (compute, network,

storage, VM and applications). Here is a list of design considerations:

UCS

Cisco UCS blade chassis has redundancy for all components

Two UCS blade servers in case one of them fails

Dual UCS Fabric Interconnect configured as a cluster

UCS fabric NIC failover is used for management and virtual machine traffic

Page 14: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 4

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

CISCO UCS 6248UP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

STAT

ID

CISCO UCS 6248UP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

STAT

ID

! Reset Console

UCS B230 M1/M2

!2!1

A03-D0100SSD-LH 100GB SSD SATA>> A03-D0100SSD-LH 100GB SSD SATA>>! Reset Console

UCS B230 M1/M2

!2!1

A03-D0100SSD-LH 100GB SSD SATA>> A03-D0100SSD-LH 100GB SSD SATA>>

1

VMware vSphere

2

3

Figure 4 - UCS Availability – Key Points

Figure 5 - Redundant Networks

Page 15: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 5

Figure 6 - Automated Network Failover

Storage

Nimble Storage CS-series array has redundancy for all components

All volumes provisioned use SATP_ALUA & PSP_RR for path failover and load

distribution

Figure 7 – Storage MPIO – Round Robin Path Selection

Page 16: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 6

Set iops=0 for

each volume

All volumes

should have

“iops=0”

Figure 8 – ESXi Storage Device Settings

vSphere

vSphere HA enabled to auto restart VMs in case ESXi server fails

Host monitoring is enabled to monitor heartbeat of all ESXi hosts in the cluster

Admission control is enabled to ensure the cluster has enough resources to

accommodate a single host failure

N+1 configuration to tolerate for one ESXi host failure

vSphere Virtual Switch layout (only single vNIC is needed as UCS Fabric failover is

enabled for each management and virtual machine traffic vNIC; more on the iSCSI

vSwitch later)

Figure 9 - Hypervisor HA

Page 17: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 7

Figure 10 - Virtual Network Separation

Performance Optimization

This section covers various performance optimization considerations in the configuration of the

SmartStack solution.

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

CISCO UCS 6248UP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

STAT

ID

CISCO UCS 6248UP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

STAT

ID

! Reset Console

UCS B230 M1/M2

!2!1

A03-D0100SSD-LH 100GB SSD SATA>> A03-D0100SSD-LH 100GB SSD SATA>>! Reset Console

UCS B230 M1/M2

!2!1

A03-D0100SSD-LH 100GB SSD SATA>> A03-D0100SSD-LH 100GB SSD SATA>>

1

2

3 VMware vSphere

OS

APP

DATA

OS

APP

DATA 4

Figure 11 - Optimization Locations

Page 18: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 8

UCS (#1)

Dual subnet for directly connecting Nimble to Cisco UCS Fabric Interconnect (without

failover of Fabric for the iSCSI vNICs)

Figure 12 - iSCSI Storage Subnets

Storage (#2)

Storage Volume layout

Volumes supporting the infrastructure

Volumes supporting the application

Performance Policy for each storage volume:

Use PSP_RR to distribute I/O across both paths

Change default path IOPS to 0

Infrastructure AD

vCenter Server

vCenter Opreations

OS VMDK for all VMs

VMKD for Sharepoint

(web/app tiers)

Dedicated datastore

for all VM swap

(.vswp)

bizappVMswap

Boot volume

(ESXi1)

Boot volume

(ESXi1)

Figure 13 – Infrastructure Specific Volume Assignemnt

Page 19: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 1 9

ExchangeDB

ExchangeLog

SQL2012DB

SQL2012Log

Figure 14 - Application Specific Volume Assignment

For VM .vswp swap

For infrastructure VMs and

app VM OS VMDKs

Performance Policy

Block size 4K

Compression: ON

Cache: Disabled

Block size 4K

Compression: ON

Cache: Enabled

Figure 15 - Application Aware Performance Policies

vSphere

One VMkernel port for each of the iSCSI vNIC

Software iSCSI initiator binds to two VMkernel ports

Separate OS, Data, log into its own VMDK, dedicated virtual SCSI adapter, and use

vmnxet3 as the virtual adapter

o Exchange, SQL Server, SharePoint

VM Guest OS:

o If upgraded from Windows 2003, be sure to align the VM (change partition

starting offset to be divisible by 4KB)

o NTFS allocation unit size for data/log partitions should be 64KB

Page 20: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 0

Figure 16 - vmkernel Network Allocation - vSwitch

Figure 17 - vmkernel Network Allocation - Details

Page 21: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 1

Separate VMDK

for OS, DB, Log

Separate vSCSI

HBA for each VMDK

Separate vmnic for

MAPI and DAG

replication traffic

Figure 18 - VM Properties - Exchange

Separate

vSCSI HBA

for each

VMDK

Separate VMDK

for OS, DB, Log

Figure 19 - VM Properties - SQL Server

Page 22: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 2

Separate

vSCSI HBA

for each

VMDK

Separate VMDK for

OS and Application

Figure 20 - VM Properties - SharePoint

Data Protection

Infrastructure

Backup UCSM configuration on a regular basis (service profile templates, service profiles, all

environmental configurations for the Fabric Interconnect), especially after changes have been

made (for example, modification to service profile, configuration of ports/VLANs in the Fabric

Interconnect)

Backup ESXi sever boot volumes and infrastructure VMs (including SharePoint Web/App tier) by

placing all boot volumes into a single Volume Collection with daily snapshot (NOTE: No snapshot

synchronization is needed as crash consistent snapshot is all that’s needed)

Application

Ensure application consistent snapshot can be taken through Nimble and VMware integration

Exchange

o For simplicity, each Exchange mailbox database is configured with circular

logging

o NOTE: The ability to perform log truncation is provided through add-on products

such as CommVault Simpana with Nimble Storage integration or vSphere Data

Protection

o VMware VSS integration is used to properly quiesce Exchange database for

application consistent snapshot

Page 23: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 3

o VMware vCenter Synchronization is used for the Exchange Volume Collection

(the volume collection contains both Exchange database and log datastores)

SQL

o For simplicity, each SQL database is configured with simple recovery mode

NOTE: The ability to perform full recovery is provided through add-on products

such as CommVault Simpana with Nimble Storage integration or vSphere Data

Protection

o VMware VSS integration is used to properly quiesce SQL database for

application consistent snapshot

o VMware vCenter Synchronization is used for the SQL Volume Collection (the

volume collection contains both database and log datastores)

SharePoint

o The SharePoint Web/Application tier VMDK resides in the Infrastructure volume

which is backed up daily. Note the SharePoint database is backed up through

SQL Server volume collection

Figure 21 - Backup UCSM

Page 24: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 4

Infrastructure

ESXi1 boot

ESXi2 boot

Infrastructure VolCol

(daily snapshot)

Figure 22 - Nimble Volume Collection Protection Scheme

1

2

3

Figure 23 - Nimble Storage Snapshot Synchronization - Exchange

2

1

3

Figure 24 - Nimble Storage Snapshot Synchronization - SQL Server

Operational Management

In this chapter we will highlight tools and integrations that help making deployment and

operational management simple and easy.

Server Deployment with Cisco UCS Service Profile

Page 25: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 5

A custom UCS Service Profile template was created for vSphere. It creates a standard for

deploying the vSphere environment serving business critical applications, and simplifies scalability

expansion down the line. We created two service profiles based on this ESXi template, apply it to

each blade, and then modify the boot target for each server. That is it – all subsequent servers

that will be added to the environment serving business critical applications will follow the same

steps. Here’s what the service profile template looks like:

For vNIC

Figure 25 - UCS vNIC Allocation

iSCSI vNICs settings for Boot-from-SAN

A1: subnet A for iSCSI boot vNIC A

A2: iSCSI Discovery IP address for Nimble Array

B1: subnet B for iSCSI boot vNIC B

B2: iSCSI Discovery IP address for Nimble Array

Page 26: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 6

A1

A2

B1

B2

Figure 26 - iSCSI Boot from Nimble

Storage Management with Nimble Storage vCenter plugin

Don’t want to toggle between different UIs to perform storage related tasks? Just stay in vCenter

Server. Nimble Storage plugin allows for new datastore provisioning, cloning, resizing,

snapshotting, and monitoring performance statistics, space usage, and compression savings:

Performance

/Space

monitoring

Figure 27 - vCenter Storage Integration

Operational Management with vCenter Operations Manager

After the environment has been deployed, use vCenter Operations Manager to monitor health,

workload and faults in the infrastructure. Good practice is to pay attention to any red icon(s) for

Health, Workload and Fault badges, as well as “Alerts”:

Page 27: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 7

Figure 28 - vCenter Operations Manager

You could also leverage the Group view functionality to look at the current health and workload

status of all the VMs by their grouping folder:

NOTE: It is recommended to create a custom group with all Nimble Storage datastores. Doing so

allows for quick overview of the health and workload status of the Nimble array volumes. Nimble

InfoSight could then be used to look at deeper statistics based on heartbeats sent from the array.

Figure 29 - vCOps - Applications

Page 28: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 8

Figure 30 - vCOps Health

Deep Data Analytics with Nimble InfoSight

It is a good practice to regularly monitor Nimble InfoSight for storage health, availability,

performance, data protection reports based on heartbeats from the array:

Wellness tab shows alerts from the array (both hardware and software), as well as support cases

that have been open automatically based on criticality of the alerts:

Figure 31 - InfoSight Wellness Overview

Capacity tab shows current array space utilization, as well as projection of when the array would

run out of capacity:

Page 29: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 2 9

Figure 32 - InfoSight Capacity Usage

Page 30: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 0

Performance tab shows CPU and cache utilization of the array, as well as average read and write

latency based on heartbeat sent by the array:

Figure 33 - InfoSight Performance View

Data Protection tab shows snapshot/replication configuration for each volume within the Nimble

array:

Page 31: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 1

Figure 34 - InfoSight Protection Coverage View

Page 32: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 2

Dashboard tab shows summary reports of space savings through compression, data protection

level for each volume, snapshot retention duration as well as upgrade recommendations based on

workload

Figure 35 - InfoSight Executive Dashboard

Modular Virtual Desktop Infrastructure

The Horizon View desktop virtualization environment was configured with the following

components:

Cisco UCS B-series (10-Gbps Cisco UCS)

Nimble Storage CS200 Series array (10-Gbps iSCSI)

VMs to support the following functions:

o Active Directory, DNS, and DHCP

o Microsoft KMS

o VMware View Planner

o VMware vCenter

o Microsoft SQL Server

o VMware Horizon View Composer

o VMware Horizon View Connect

125 Microsoft Windows 7 Desktops per Cisco UCS B-series blade

Page 33: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 3

Cisco UCS B-Series Blade Servers

The VMware Horizon View test was performed on a Cisco UCS blade system targeted to host

approximately 125 desktops per blade. For the targeted 500 desktop user test, four blades were

configured into a VMware VDI service cluster. For details on the specific blades used, refer to

Appendix A.

VMware vSphere

For this test, VMware vSphere and Horizon View were deployed. All Cisco UCS blades were

configured to iSCSI boot the VMware ESXi hosts from the Nimble Storage.

A VMware Horizon View Infrastructure host blade was used to support the VDI components,

which include the following Microsoft Windows Server 2008 R2 virtual machines:

Microsoft Windows Active Directory, Domain Name System (DNS), and Dynamic Host

Configuration Protocol (DHCP)

Microsoft Key Management Server (KMS)

VMware vCenter Server

VMware Horizon View Connection Server (View Manager)

VMware Horizon View Composer

Microsoft SQL Server (to support the VMware infrastructure)

VMware View Planner appliance (Linux based) to run the real-world workload tests

The desktop virtual machines were run on a virtual desktop cluster composed of four dedicated

Cisco UCS B-series blades.

The desktop configuration used for this test was a Microsoft Windows 7 Professional (x86 32-bit)

virtual machine with 1 GB of RAM, one virtual CPU (vCPU), and a 24-GB disk.

The software configuration of the desktop application environment consisted of:

Microsoft Office 2007 (Word, Excel, and PowerPoint)

Microsoft Outlook

Adobe Reader

Mozilla Firefox

7-Zip tools

Also configured in the Microsoft Windows 7 golden image were the VMware Horizon View Agent

and the VMware View Planner Agent. The configuration of the golden image followed the

VMware View Planner guide for optimizations, system settings, and other configuration

requirements. For details about the specific setup, refer to Appendix A of the VMware View

Planner Installation and User Guide.

Page 34: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 4

VMware Horizon View

VMware Horizon View was used to construct and manage the desktop virtual machines. This test

used a floating pool of non-persistent linked-clone desktop virtual machines. The details of the

specific VMware Horizon View pool definition are included at the end of this document.

In addition to the linked-clone method of deploying desktop virtual machines, VMware Horizon

View uses VMware VSA technology. This technology allows a small amount of VMware ESXi

host RAM to be used as a content-based read cache for the selected desktops’ read I/O

operations. VMware VSA was configured at 2 GB for each VMware ESXi host and for each

VMware Horizon View pool used for this test.

VMware View Planner

To perform the workload test, the VMware View Planner tool was used to run a sample workload

on each of the 500 active Microsoft Windows 7 desktops. The VMware View Planner tool can be

configured in many ways for configuration testing. This test followed the guidelines of the VMware

Rapid Desktop Program (RDP) testing. The result of the VMware View Planner workload is close

to that for a typical Microsoft Windows–based task worker with a steady-state IOPS rate of about

7 IOPS per desktop.

Nimble Storage CS-Series

The Nimble Storage system used for this testing was a CS220G-X4 model that has 12 TB of raw

capacity (12 x 1-TB HDD), 1200 GB of SSD-based flash memory, and dual 10 Gigabit Ethernet

data network interface card (NIC) connections per controller. The Nimble Storage CS220G-X4

has two controllers operating in an active-standby redundant configuration.

For the 500 desktop virtual machines solution, the storage volumes were configured to have no

more than 125 desktop virtual machines in each VMware Virtual Machine File System (VMFS)

datastore. Each datastore volume was configured with 3 TB, using thin provisioning at the

storage level and providing plenty of room at the linked-clone level for conservative desktop

provisioning methods. The Nimble Storage appliance was then configured with 5 of the 3 TB

iSCSI volumes presenting 5 individual datastores at the VMware level. Each Cisco UCS blade

had shared access to each volume. Through the VMware Horizon View pool balanced allocation,

each volume contained approximately 100 desktop linked-clone virtual machines.

The VMware Horizon View storage component that mapped to the Nimble Storage solution used

a simple and easy-to-manage approach: everything for the desktop was in the same datastore.

With Nimble Storage capabilities, it is not necessary to separate the various VMware Horizon

View storage artifacts into different storage tiers or locations. The CASL file system is optimized

to handle VDI workloads, including boot storms. During a boot storm, the virtual desktop replica

image is automatically cached in the built-in SSDs. As a result, boot times are greatly reduced,

even when large numbers of virtual desktops boot at the same time. During steady-state

operations, in which end users access applications in a random fashion, random write I/O is also

optimized with the CASL write-coalescing technology.

Page 35: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 5

Solution Validation

As part of the reference architecture development practice, we constructed an example

configuration of Nimble Storage, Cisco UCS and VMware ESXi hosts for running the sample load

test utilities from the desired server application and desktop virtualization solution sets.

The next sections will describe some of the detail of the solution configuration.

Server: Cisco UCS

The Cisco UCS configuration was connected to the Nimble Storage as an iSCSI array directly to

the Cisco fabric interconnect with dual, redundant 10-Gbps connections. This architecture

provides the most efficient use of hardware and lowers the total cost (cost per desktop) of the

server, network, and storage solution.

The chassis is connected to each fabric interconnect with four 10-Gbps network connections.

Active/Passive Fabric

Interconnect

Active-Passive Fabric

Interconnect

Figure 36 – UCS Fabric Interconnect – Appliance Port VLAN Connectivity

Active-Passive Fabric Interconnect

For a configuration without an access-layer switch (Cisco Nexus® 5000 Series Switches), the

fabric interconnect ports connected to the Nimble Storage array must be configured to operate in

Appliance Port mode.

Page 36: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 6

Figure 37 - UCS Appliance Port Configuration

The Cisco UCS B-series Blade Servers were configured with multiple virtual NIC (vNIC) interfaces

to allow separation of management traffic, VDI desktop traffic, and iSCSI data traffic. The

following figure shows a typical server service profile.

Figure 38 - Cisco UCS Blade Server vNIC Configuration

Each Cisco UCS blade server is configured with five vNIC interfaces, with the VMware ESX

vSwitch network configuration shown here:

vSwitch0 (management network)

vmnic0

vSwitch1 (iSCSI data traffic)

vmnic1 and vmnic2 (no teaming; VMware ESX software iSCSI multipathing is enabled

with PSP_Round_Robin algorithm)

vSwitch2 (virtual desktop traffic)

Page 37: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 7

vmnic3 and vmnic4 (teamed for load distribution and failover)

Figure 39 - VMware Network Configuration

Figure 40 - VMware iSCSI Port 1 Configuration Details

Page 38: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 8

Figure 41 - VMware iSCSI Port 2 Configuration Details

Figure 42 - VMware Desktop Virtual Machine Network Configuration Details

Storage: Nimble Storage CS-Series

The Nimble Storage CS220G-X4 was configured with multiple volumes presented to the Cisco

UCS VDI cluster as shown in the figures that follow. Each of the 5 volumes was configured as 3

TB of thin-provisioned iSCSI SAN storage VMFS datastore.

The iSCSI initiators of the Cisco UCS blades were defined in a single initiator group for ease of

management and presentation. Nimble Storage allows all host initiator iSCSI qualified names

(IQNs) to be grouped into a single group, which eases the need to provision storage for multiple

groups of VMware ESX host initiators. This approach is a best-practice recommendation for

VMware vSphere environments, because it prevents inconsistent performance policy settings and

Page 39: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 3 9

volume presentations to a VMware ESX host cluster that shares the same group of volumes. The

following figure shows the grouping of all VMware ESX hosts in the VDI environment sharing a

single initiator group. The initiator group is constructed by adding the IQN information for each

blade’s iSCSI initiator in a single combined group representing the VMware ESX cluster formed by

the blades.

Figure 43 - Nimble Storage iSCSI Initiator Setup

The 5 VMFS datastores were then configured into separate VMware Horizon View pools as

described in Appendix C VMware Horizon View Pool Details.

Figure 44 - Nimble Storage Volume Management

VDI: VMware

The VMware vSphere and View environment was set up with a single cluster of VMware ESXi

hosts for the VDI configuration.

Page 40: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 0

Figure 45 - VDI Cluster Configuration – vCenter Organization

Four of the Cisco UCS blades in this chassis were used to host the Microsoft Windows 7 desktop

virtual machines, and a separate blade was used to provide the core virtualization infrastructure

services as described in the following paragraphs.

Testing Methodologies

This section will describe the basic testing approach taken to validate the reference architecture

capabilities and performance.

To validate the capability to run up to 500 desktop virtual machines on the Nimble Storage

CS220G-X4 array, the VMware View Planner tool was used to run sample tests for specific

configurations. The goal was to exercise and measure the storage infrastructure under a

reference workload. The workload consisted of the following:

500 desktop virtual machines configured into five VMware Horizon View pools of 100

desktops each

Four blade servers in a Cisco UCS and VMware cluster, each running approximately 125

virtual machines based on VMware Horizon View pool allocations for the cluster resource

All 500 virtual desktops configured in floating pools (they represent non-persistent

desktops used by task workers, with random workloads throughout the day)

Page 41: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 1

As shown in the workload profile in the figure below, a typical VMware View Planner configuration

consists of a set of applications to exercise and a set of virtual machines on which to run that

workload profile.

The next figure shows examples of the VMware View Planner Workload Profile and the VMware

View Planner Run Definition used for the test of the Nimble Storage and Cisco UCS VDI solution.

For this test, all applications were selected for the workload profile. The Multimedia Application

value was set to Medium but unchecked for this test scenario. The Iterations value should be set

to at least 7 to allow ramp up and ramp down of the individual desktop workloads during the test

run and still obtain 5 iterations for steady-state measurements. For this test scenario we used an

iteration count of 10 to mimic the ramp up and down of roughly an 8 eight work day and coincided

with the 10 hour runs of Exchange Loadgen and SQL DVD-Store load testing.

The Think Time setting was used to adjust the intensity of the desktop activity. Think Time

dictates the average interval that each user session waits before moving on to the next workload

profile task and can be a value between 5 and 20. For the 500 desktop tests for average use

cases, a Think Time value of 20 was used.

This selection of run profile characteristics is representative of a workload in the range of 7 to 10

IOPS per user, or comparable to a user roughly between a task worker (3 to 7 IOPS) and

knowledge worker (7 to 10 IOPS).

Figure 46 - VMware View Planner Workload and Run Profile

Boot and Login Scenarios

The VMware View Planner tool allows control of an orderly boot and login sequence when you are

performing a test run. For the workload tests performed, the desktop virtual machines were

rebooted each time before the workload was processed. This approach allowed measurement of

the boot and login process in addition to the measurement of the actual desktop workload

processes.

The four Cisco UCS blades are configured in a VMware cluster, and the VMware Horizon View

pools and datastores are shared across the set. This approach provides greater simplicity of

management for the environment and allows better distribution of the computing assets.

Page 42: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 2

The total time to boot 500 desktops and have the VMware View Planner agent log in is

approximately 15 minutes. This time is measured by the completion of the VMware Horizon View

Agent registration with the VMware Horizon View Administrator and the VMware View Planner

Agent registration with the VMware View Planner appliance. Keep in mind that the desktop

sessions are booting to an operational state and automatically logging in the test user

(administrator), who then connects to the VMware View Planner harness. This user registration

takes a little extra time, but it allows you to monitor the ready state of the desktop virtual machines

under test.

The effect on the Nimble Storage appliance during the boot storm period can be seen in the next

figure, which contains two graphs:

MBps throughput

IOPS

These graphs show the performance for the “typical day” test run used and shows that the storage

infrastructure is delivering data well within the operational specifications expected. The system

under test is capable of approximately 15,000 mixed-workload IOPS during the initial boot/login

phase. Throughput is simply a result of the I/O rate and block sizes coming from the desktop

virtual machines.

Figure 47 - Nimble Storage Performance - Day View

Steady-State Scenarios

Page 43: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 3

As you can see, the transition to desktop user steady state around 8:00 AM causes a dramatic

shift in the number of random read operations required to support the desktop workload. As the

desktop virtual machines shift into various VMware View Planner tasks as defined by the workload

profile, the random write operations become the dominant factor, at three to four times the number

of random read I/O operations.

The following figure from the View Planner results documentation shows that during the steady

state, the CPU utilization of the desktop ESXi host is within the performance bounds desired for

each blade in the Cisco UCS blade system.

Figure 48 - Cisco UCS Blade - Steady State Workload - CPU Utilization

Conclusion

The combined desktop and server solution test conducted with the Cisco UCS B-Series Servers,

Nimble Storage array, and VMware vSphere using Microsoft applications and Horizon View

showed that a robust yet simple configuration is possible for up to 500 users in a mixed workload

environment on the same easy to manage, scalable and well performing virtualization

infrastructure.

When you virtualize business critical applications such as Microsoft Exchange, SQL and

SharePoint, be sure to design the architecture with the four key pillars of requirements in mind:

availability, performance, data protection and operational management. This document highlights

the key design principles and best practices that address the requirements from all four pillars.

Virtualize with confidence using SmartStack, powered by Cisco, VMware and Nimble Storage.

Page 44: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 4

Appendix A: Bill of Materials

Table 1 shows the bill of materials (BOM) for the test configuration.

Vendor Component Model (Quantity) Version

Cisco Cisco UCS B230 M2 Blade Server (6) 2.1(3a)

Cisco UCS 2200 Series Fabric Extenders

Cisco UCS 5108 Blade Server Chassis (1)

Cisco UCS 6248 48-Port Fabric Interconnect (2)

Nimble Storage Nimble Storage CS220G-X4 (1) 1.4.9.0

VMware VMware vSphere ESXi Enterprise Plus 5.1 U1

VMware vSphere vCenter Server Standard 5.1

vCenter Operations Manager 5.7

VMware Horizon View Premier 5.3

VMware View Planner (optional) 3.0.1

Note:

The B.O.M listed above is a reference design of an environment capable of supporting 500+ users

with business critical applications. Customers and partners are welcome to use different models

of equipment from Cisco for compute, and Nimble for Storage. For example, Cisco UCS C-series

rack mountable servers or other blade models, and a Nimble CS400 series could be used in place

of the CS200 series, depending on the workload and capacity needs.

Page 45: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 5

Appendix B: Validation for 500-User Business Critical Applications Environment

High Level Environment Overview:

CISCO UCS 6248UP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

STAT

ID

CISCO UCS 6248UP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

STAT

ID

SLOT

1

SLOT

5

SLOT

3

SLOT

7

SLOT

2

SLOT

6

SLOT

4

SLOT

8

!

UCS 5108

OK FAIL OK FAIL OK FAIL OK FAIL

! Reset Console

UCS B230 M1/M2

!2!1

A03-D0100SSD-LH 100GB SSD SATA>> A03-D0100SSD-LH 100GB SSD SATA>>! Reset Console

UCS B230 M1/M2

!2!1

A03-D0100SSD-LH 100GB SSD SATA>> A03-D0100SSD-LH 100GB SSD SATA>>

VMware vSphere

VMware vCenter

Nimble Storage InfoSight

vCenter Operations Manager

Figure 49 - Business Critical Applications

Exchange 2010:

1 Database Availability Group

CAS/Hub/Mailbox Server 1

Mailbox DB 1Mailbox DB 2

(copy) Mailbox DB 2Mailbox DB 1

(copy)

250 mailboxes 250 mailboxes

CAS/Hub/Mailbox Server 2

Exchange LoadGen VM

Figure 50 - Exchange 2010 Architecture

Page 46: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 6

Figure 51 - Exchange 2010 Detailed Setup

SQL 2012 and SharePoint 2013:

SQL2012 Infrastructure SQL2012 Application

vCenter Server DB

DVDStore DB

SharePoint DB

VMware

vCenter Server

DVDStore SQL Load Driver VM

MyNimble Intranet Powered by SharePoint

Web/App Tier

Figure 52 - SQL and SharePoint Database Architecture

In case you are wondering how the SmartStack solution performs with real applications, here are

the details of the validation:

In short, the physical servers, VMs hosting the applications, and the Nimble CS220G-X4 array did

not show any signs of resource starvation. The environment could definitely take on additional

workload. We leverage vCenter Operations Manager to determine the impact of running all

workloads simultaneously, and here are the results:

Page 47: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 7

Summary of observations:

Mixture of Exchange, SQL and SharePoint workload shows both random and sequential read and

write, with bursts of up to 15,000 IOPS

The SmartStack architecture is well equipped to handle the mixture of workloads without signs of

resource starvation for CPU, memory, network or storage (as shown in vCenter Operations charts

below)

Nimble CS220G-X4 array shows average latency of under 2 ms for both read and write IO

Details:

Application Validation Tool Workload Profile

Microsoft Exchange 2010 LoadGen Version 14. 01.

0180. 003

500 1GB mailboxes (250 in

each DAG node with cross

replication); Outlook_150

action profile (150

messages/day); total of 10

hour test simulating 8 hour

busy work day

Microsoft SQL Server 2012 DVDStore Version 2. 1 Large DVDStore database

with 1 million customers and 2

million DVD products

Microsoft SharePoint 2013 Nimble Storage employees Day-to-day cross functional

usage of SharePoint farms for

page creation, modification,

file upload and sharing

NOTE: Validation was conducted with all three workloads and VMware View Planner 500 user

desktops running simultaneously.

Results:

Page 48: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 8

Figure 53 – Exchange LoadGen Results

DVDStore Results:

Total test run duration: 36018 minutes (~10 hours)

Total transactions completed: 1892280 orders

Total new customers added: 378376

Total number of browse during run: 5677543

Total number of purchases: 1892280

Average latency per second to login to DVDStore: 6 millisecond

Average latency to add new customer: 1 millisecond

Average latency to browse catalog: 1 millisecond

Average latency to purchase: 9 millisecond

Figure 54 - DVDStore Run Results

SharePoint Access

Page 49: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 4 9

Nimble employees across HR, Engineering, QA, Product Management, Marketing, IT and Sales

all had access to “MyNimble” (Nimble’s intranet backed by SharePoint 2013 with SQL 2012 back-

end). All team members were able to access various intranet pages, upload and edit shared

documents, while Exchange Loadgen and DVDStore workloads were running on the SmartStack.

Figure 55 - Example SharePoint Page 1

Figure 56 - Example SharePoint Page 2

Resource Utilization

Page 50: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 0

Figure 57 - ESXi Server 1 Resource Utilization

Figure 58 - ESXi Server 2 Resource Utilization

Page 51: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 1

Figure 59 - Exchange DAG node 1 Resource Utilization

Figure 60 - Exchange DAG node 2 Resource Utilization

Page 52: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 2

Figure 61 - SQL DB serving DVDStore and SharePoint databases Resource Utilization

Figure 62 - Nimble Storage CS220G Array IOPS and Latency chart

Page 53: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 3

Page 54: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 4

Appendix C: Storage Performance

Boot Storms

Approximately 15 minutes were needed to boot and log in 500 desktops.

Figure 63 - Boot Storm Storage Performance

Steady State

Approximately 8 hours were monitored. This included (as described earlier):

rollout of the test work load on 500 desktops and the cycling through approximately 8 of

the 10 iterations,

Exchange LoadGen workload,

SQL Server DVD-Store load test.

Page 55: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 5

Figure 64 – Combined Working Day Storage Performance

Page 56: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 6

Appendix D: Horizon View Pool Details

The VMware Horizon View pools were configured as automated, linked-clone, and floating pools.

To test 500 desktops, two VMware Horizon View pools of 300 & 200 desktop virtual machines

were created in each pool.

Figure 65 - VMware Horizon View Pool Configuration

Each pool had separate datastores provisioned to it from the Nimble Storage volumes presented

to the VMware ESXi hosts. Each datastore was targeted to hold 100 desktop VMs. The replica

and OS disks were placed in the same datastore primarily for simplicity of management.

Figure 66 - View Pool Storage Configuration – Pool 1

Page 57: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 7

Figure 67 - View Pool Storage Configuration - Pool 2

All desktops were provisioned at the start and created during a separate provisioning period

before the testing was performed. Disposable disks were not selected for the particular test

cases.

For this configuration of basic testing, the VMware Horizon View VSA (View Storage Accelerator)

function was not selected.

Figure 68 - VMware Horizon View Advanced Storage Settings

The VM baseline image was updated to the latest version (vmx-09) to allow compatibility with SE

Sparse functionality. Storage reclamation was not configured for the baseline testing.

All other VMware Horizon View pool settings were default values or those specified in the VMware

View Planner Installation and Users Guide.

Page 58: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 8

Appendix E: VDI Planning and Sizing Questions

You must understand user groups, applications, and data requirements to properly size

computing, networking, and storage resources.

Some general project questions should be addressed at the outset:

Has a VDI pilot plan been created based on the business analysis of the desktop groups,

applications, and data?

Is the infrastructure and budget in place to run the pilot program?

Are the skill sets needed to implement the VDI project available? Can these be acquired

through hiring or contract?

Have end-user experience performance metrics been identified for each desktop

subgroup?

How will success or failure be measured?

The following is a short, non-exhaustive list of sizing questions that should be addressed for each

user subgroup:

What is the desktop OS planned? Microsoft Windows 7 or Windows XP, 32-bit or 64-bit

desktop OS?

How many virtual desktops will be deployed in the pilot? How many are in production?

Will all desktops use Microsoft Windows 7?

How much memory is needed per target desktop group desktop?

Are there any multimedia, Adobe Flash, or graphics-intensive workloads?

What is the endpoint graphics processing capability?

Are any VMware ThinApp applications planned? Will they be packaged or installed?

What is the storage configuration in the existing environment?

Are sufficient I/O operations per second (IOPS) available for the write-intensive VDI

workload?

Will storage be dedicated and tuned for VDI service?

Does the desktop have a voice component?

Is antivirus software a part of the image?

Is user profile management (non-roaming profile based) part of the solution?

What are the fault-tolerance, failover, and disaster recovery plans?

Are there any additional desktop-subgroup-specific questions that need to be addressed?

Page 59: SmartStack Reference Architectures Nimble Storage ... · Figure 21 - Backup UCSM . NIMBLE STORAGE SMARTSTACK REFERENCE ARCHITECTURE SERIES 24 Infrastructure ESXi1 boot ESXi2 boot

N I M B L E S T O R A G E S M A R T S T A C K R E F E R E N C E A R C H I T E C T U R E S E R I E S 5 9

Nimble Storage, Inc.

211 River Oaks Parkway, San Jose, CA 95134

Tel: 877-364-6253; 408-432-9600 | www. nimblestorage. com | info@nimblestorage. com

© 2014 Nimble Storage, Inc. . Nimble Storage, InfoSight, CASL, SmartStack, and NimbleConnect are trademarks or registered trademarks of Nimble Storage, Inc. All other trademarks are the property of their respective owners. SS-DSV-REF-0214