solar drive for pump motor_dm02.pdf · solar motor inverter water pump aerator dc power ac power ac...

2
XB200205 1805 Ver1 / 1912 Powered by Solar Energy Drive Your Green Future Solar Drive for Pump RM6F5 Series 0.75kW-22kW

Upload: others

Post on 26-Aug-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Solar Drive for Pump Motor_DM02.pdf · Solar Motor Inverter Water Pump Aerator DC Power AC Power AC DC High energy efficiency, reduces your carbon footprint. Fully automatic system,

XB200205 1805 Ver1 / 1912

Powered by Solar EnergyDrive Your Green Future

Solar Drive for PumpRM6F5 Series 0.75kW-22kW

Page 2: Solar Drive for Pump Motor_DM02.pdf · Solar Motor Inverter Water Pump Aerator DC Power AC Power AC DC High energy efficiency, reduces your carbon footprint. Fully automatic system,

Fault ProtectionBuilt-in MPPT Dual power Automatic Start/Stop

PV Cell

Power Grid AC/DCSwitch

Solar Motor Inverter

Water Pump

Aerator

DC Power

AC Power

AC DC

High energy efficiency, reduces your carbon footprint.

Fully automatic system, uses variable speed drives compatible with AC, 3-phase, submersible and surface mount pumps.

As it is more efficient to store water than to store electricity, energy storing devices (eg. batteries) are excluded from the system.

The system is prepared to be incorporated with an elevated water storage, e.g. a water tower or an uphill tank installation.

Product series

Maximum Applicable Motor(HP)

Application: Solar Motor Inverter

Input Voltage2: AC 200~240V or DC 125~400V4: AC 380~480V or DC 270~800V

Features of Solar Pump Inverter System Description

Application

Irrigation of landDemostic WaterSupply

Fishing FarmingSwimming PoolFountain Livestock

Built-in MPPT (Maximum Power Point Tracking), maximizes your power output.

Supports dual power mode from 3Φ or 1Φ AC power or DC power of solar arrays.

Built-in pump protection function in case of dry run, over pressure…etc.

Automatic start and stop according to sunrise and sunset or sudden power cuts.

Automatic start and stop function is compatible with level sensors, capable of controlling water level inside the overhead tank.

Model Number Scheme

RM6F5-2 001-0713

Standard Specifications

Modle Name (RM6F5-□□□□)

200V Series 400V Series

Maximum Applicable Motor (HP/kW)

2001 2002 2003 2005 2007 2010 2015 2020 4001 4002 4003 4005 4007 4010 4015 4020 4025 4030

1/0.75

1.6

4.2

2/1.5

2.6

6.8

3/2.2

3.8

10

5/3.7

5.8

15.2

Three-Phase 200~240V

176~264V 50/60Hz /±5% 332~528V 50/60Hz /±5%

120% of drive rated output current for 1 min 120% of drive rated output current for 1 min

IP20 IP20

Fan cooling Fan coolingNaturecooling

Naturecooling

0.1~120.0Hz

Three-Phase 380~480V

0.1~120.0Hz

3ø 200~240V 50/60Hz ; DC 125~400V 3ø 380~480V 50/60Hz ; DC 270~800V

7.5/5.5

9.5

25

10/7.5

12

31

15/11

16

42

20/15

22

58

1/0.75

1.9

2.5

2/1.5

2.7

3.5

3/2.2

3.7

4.8

5/3.7

6.1

8

7.5/5.5

8.4

11

10/7.5

13

17

15/11

17

22

20/15

23

30

25/18.5

28

37

30/20

34

45

5 8 12 18 30 41 55 66 3 4.2 5.8 9.6 13 20 25 38 42 52

1.8 1.8 1.9 2 3 3 5.4 5.7 1.8 1.8 1.9 2 2 3.1 3.1 5.6 5.7 5.8

Rated Output Capability (kVA)

Rated Output Current (A)

Rated Output Voltage (V)

Range Of Output Frequency (Hz)

Power Source (ø, V, Hz)

Input Current (A)

Permissible AC power source fluctuation

Overload Protection

Cooling Method

Protective Structure

Weight/Mass(kg)

Case Code Case 1 Case 1Case 2 Case 2 Case 3Case 3

System Structure

A

A

B

B

C D C

D