solarflex -x pv1-f - solaricashop.com

1
SOLARFLEX ® -X PV1-F Properties Cable structure Technical data Tinned copper-conductor, to DIN VDE 0295 cl.5, fine-wire, IEC 60228 cl.5 Temperature range -40°C to +90°C max. temperature at conductor +120°C Double-insulated Ozone resistant acc. to EN 50396 Weather und UV resistant acc. to HD 605/A1 Core insulation of cross-linked Polyolefin • Short circuit temperature 200°C (short circuit duration up to 5 s) Core identification white Halogen-free acc. to DIN EN 50267-2-1, EN 60684-2 Outer sheath of cross-linked Polyolefin • Nominal voltage VDE 600/1000 V AC 1800 V DC conductor/conductor Resistant to acid and bases acc. to EN 60811-2-1 Sheath colour see table below with meter marking Flame retardant to DIN VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) • AC test voltage 10000 V • Minimum bending radius flexing 10x cable Ø fixed installation 4x cable Ø Very robust and abraison-resistant sheath acc. to DIN EN 53516 Anticipated service life: 25 year • Highest permissible Voltage • DC: Conductor/Conductor 1,8 kV Conductor/Earth 0,9 kV • AC: Conductor/Earth 0,7 kV • Three phase: Conductor/Conductor 1,2 kV Hydrolysis and ammoniac resistant Approvals According to PV1-F requirement profile for PV cable DKE / VDE AK 411.2.3 VDE (Reg. 8266) TÜV (2 PfG 1169 / 08.2007, R60025298) UL certification in progress (UL Subject 4703) Note Not for direct installation in ground Version with rodent protection available: SOLARFLEX ® -X PV1-F NTS Application The SOLARFLEX ® -X PV1-F is used for cabling solar modules. = The product is conformed with the EC Low-Voltage Directive 2006/95/EC. AWG-No. Weight app. kg / km Cop. weight kg / km Outer Ø app. mm Sheath colour No.cores x cross-sec. mm² Part no. 14 42,0 24,0 4,5 black 1 x 2,5 704225 14 42,0 24,0 4,5 blue 1 x 2,5 705892 14 42,0 24,0 4,5 red 1 x 2,5 705891 12 60,0 38,4 5,2 black 1x4 704226 12 60,0 38,4 5,2 blue 1x4 705776 12 60,0 38,4 5,2 red 1x4 705775 10 82,0 57,6 5,9 black 1x6 704227 10 82,0 57,6 5,9 blue 1x6 705778 10 82,0 57,6 5,9 red 1x6 705777 8 123,0 96,0 6,9 black 1 x 10 704228 8 123,0 96,0 6,9 blue 1 x 10 705894 8 123,0 96,0 6,9 red 1 x 10 705893 6 190,0 153,6 8,3 black 1 x 16 704229 6 190,0 153,6 8,3 blue 1 x 16 706840 6 190,0 153,6 8,3 red 1 x 16 706839 4 285,0 240,0 10,0 black 1 x 25 704230 2 376,0 336,0 11,0 black 1 x 35 704231 1 530,0 480,0 13,0 black 1 x 50 704232 2/0 745,0 672,0 15,3 black 1 x 70 704233 3/0 960,0 912,0 17,0 black 1 x 95 704234 4/0 1220,0 1152,0 19,1 black 1 x 120 705738 300 kcmil 1550,0 1440,0 22,7 black 1 x 150 705739 350 kcmil 1930,0 1776,0 25,5 black 1 x 185 706288 500 kcmil 2550,0 2304,0 28,3 black 1 x 240 706289 Dimensions and specifications may be changed without prior notice. 19.08.2015 / Dimensions and specifications may be changed without prior notice.

Upload: others

Post on 12-Dec-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SOLARFLEX -X PV1-F - SolaricaShop.com

SOLARFLEX®-X PV1-F 

 

PropertiesCable structureTechnical data• Tinned copper-conductor, toDIN VDE 0295 cl.5, fine-wire,IEC 60228 cl.5

• •Temperature range-40°C to +90°Cmax. temperature at conductor +120°C

Double-insulated• Ozone resistant acc. to EN 50396• Weather und UV resistant acc. toHD 605/A1• Core insulation of cross-linked Polyolefin• Short circuit temperature

200°C (short circuit duration up to 5 s) • Core identification white • Halogen-free acc. to DIN EN 50267-2-1,EN 60684-2• Outer sheath of cross-linked Polyolefin• Nominal voltage

VDE 600/1000 V AC1800 V DC conductor/conductor

• Resistant to acid and bases acc. to EN60811-2-1

• Sheath colour see table below• with meter marking

• Flame retardant to DIN VDE 0482-332-1-2,DIN EN 60332-1-2/ IEC 60332-1 (equivalentDIN VDE 0472 part 804 test method B)

• AC test voltage10000 V

• Minimum bending radiusflexing 10x cable Øfixed installation 4x cable Ø 

• Very robust and abraison-resistant sheathacc. to DIN EN 53516

• Anticipated service life: 25 year• Highest permissible Voltage• DC:  Conductor/Conductor 1,8 kV  Conductor/Earth 0,9 kV• AC: Conductor/Earth 0,7 kV• Three phase: Conductor/Conductor 1,2 kV

• Hydrolysis and ammoniac resistantApprovals• According to PV1-F requirement profile forPV cable DKE / VDE AK 411.2.3

• VDE (Reg. 8266)• TÜV (2 PfG 1169 / 08.2007, R60025298)• UL certification in progress (UL Subject4703)

 Note• Not for direct installation in ground• Version with rodent protection available:SOLARFLEX®-X PV1-F NTS

 

ApplicationThe SOLARFLEX®-X PV1-F is used for cabling solar modules.= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

 

 AWG-No.Weight

app. kg / kmCop.weightkg / km

Outer Øapp. mm

Sheathcolour

No.cores xcross-sec.mm²

Part no.

1442,024,04,5black1 x 2,57042251442,024,04,5blue1 x 2,57058921442,024,04,5red1 x 2,5705891

 

1260,038,45,2black1 x 47042261260,038,45,2blue1 x 47057761260,038,45,2red1 x 4705775

 

1082,057,65,9black1 x 67042271082,057,65,9blue1 x 67057781082,057,65,9red1 x 6705777

 

8123,096,06,9black1 x 107042288123,096,06,9blue1 x 107058948123,096,06,9red1 x 10705893

 

6190,0153,68,3black1 x 167042296190,0153,68,3blue1 x 167068406190,0153,68,3red1 x 16706839

 

4285,0240,010,0black1 x 25704230 

2376,0336,011,0black1 x 35704231 

1530,0480,013,0black1 x 50704232 

2/0745,0672,015,3black1 x 70704233 

3/0960,0912,017,0black1 x 95704234 

4/01220,01152,019,1black1 x 120705738 

300 kcmil1550,01440,022,7black1 x 150705739 

350 kcmil1930,01776,025,5black1 x 185706288 

500 kcmil2550,02304,028,3black1 x 240706289 

Dimensions and specifications may be changed without prior notice.