sonnet tutorial
DESCRIPTION
Learn how to use Sonnet high frequency softwareTRANSCRIPT
![Page 1: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/1.jpg)
Ref : Sonnet Online Manuals
Sonnet Tutorial
指導教授 :吳瑞北教授組別 :Microwave Component小組
![Page 2: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/2.jpg)
Ref : Sonnet Online Manuals
Introduction• Em performs an electromagnetic analysis of a microstrip, stripline, coplanar wavegui
de, or any other 3-D planar circuit by solving for the current distribution on the circuit metalization using the Method of Moments.
![Page 3: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/3.jpg)
Ref : Sonnet Online Manuals
Getting Stared-Microstrip Band Stop Filter
Alumina substrate: r=9.8, thickness=20 mil;guided quarter-wavelength @ 5.5GHz 206 mil
![Page 4: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/4.jpg)
Ref : Sonnet Online Manuals
Getting Stared-setting in Sonnet
Circuits to simulate are enclosed with a hermetic metal housing.Optional: lid may be removed for antenna simulation
![Page 5: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/5.jpg)
Ref : Sonnet Online Manuals
Getting Started• Choosing units
• Setting up box parameters
• Determining cell sizes
• Setting up dielectric layers
• Adding metal rectangles to a circuit
• Adding metal polygons to a circuit
• Copying, flipping and moving polygons in a circuit
• Performing a simple analysis
• Plotting response data
![Page 6: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/6.jpg)
Ref : Sonnet Online Manuals
Getting Started-Choosing units
Parameters Units
![Page 7: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/7.jpg)
Ref : Sonnet Online Manuals
Getting Started -Setting up box parameters
Parameters BoxLosslessWG loadFree space
Saving time when simulating symmetry structure
![Page 8: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/8.jpg)
Ref : Sonnet Online Manuals
Getting Started -Setting up dielectric layers
Parameters Dielectric Layers
![Page 9: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/9.jpg)
Ref : Sonnet Online Manuals
Getting Started -Adding metal rectangles and polygons to a circuit
Add a polygon Add a rectangle
Metal/Brick mode
Add port Add via
![Page 10: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/10.jpg)
Ref : Sonnet Online Manuals
Getting Started-Adding portsShift+Add port add port modePress “Esc” to exit add port mode
![Page 11: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/11.jpg)
Ref : Sonnet Online Manuals
Getting Started-Performing a simple analysis
Save then press Em
![Page 12: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/12.jpg)
Ref : Sonnet Online Manuals
Getting Started-Performing a simple analysis
• Simple sweep-For instance if the Frequency Units were set to GHz, then the values of 2, 10, 2 would start an analysis at 2 GHz and end at 10 GHz with steps of 2 GHz (e.g. 2, 4, 6, 8 and 10 GHz).
• Complex sweep-Complex sweeps are used to run an analysis using multiple sets of frequencies in sorted or unsorted order.
• Analysis file(.an)-There may be times where you will wish to analyze multiple circuits at the same set of frequencies. Rather than specifying frequency control information on an individual basis, you set the up the information once in an analysis control file.
• Verbose-Causes em to display messages in the output window during program execution describing the current state of the analysis.
• De-embed -The circuit is automatically de-embedded to the specified reference planes, or the box edge if no reference planes are specified in the geometry file.
• Memory save- The system matrix is filled in single precision which reduces memory requirements for storing the matrix to one half of that of double precision. If this option is not used, the matrix is stored in double precision.
• Make emvu file-Outputs current density information for the entire circuit which can be viewed using emvu.
• Multi-frequency caching -MFC is a technique that can dramatically reduce the em computation time when analyzing large circuits over many frequencies without any loss in accuracy.
![Page 13: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/13.jpg)
Ref : Sonnet Online Manuals
Getting Started-View response
![Page 14: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/14.jpg)
Ref : Sonnet Online Manuals
Special issue on port setting
Standard Box-Wall Ports Standard Ungrounded-Internal Ports
Via Ports Automatic-Grounded Ports
![Page 15: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/15.jpg)
Ref : Sonnet Online Manuals
Special issue on via hole setting
![Page 16: Sonnet Tutorial](https://reader036.vdocuments.net/reader036/viewer/2022081418/55cf936f550346f57b9d824b/html5/thumbnails/16.jpg)
Ref : Sonnet Online Manuals
Special issue on air bridge setting
geo3d: 可到國家高速電腦中心軟體區下載