sony hdr-fx1 adjustment ver1.4

Upload: dan-mihaescu

Post on 13-Jan-2016

35 views

Category:

Documents


0 download

DESCRIPTION

manual user

TRANSCRIPT

  • SECTION 6ADJUSTMENTS

    ADJRevision HistoryRevision History

    Ver. 1.4 2007. 09

    LinkLink

    Adjusting items when replacing main parts and boards

    Before starting adjustment

    Adjusting items when replacing main parts and boards

    Before starting adjustment

    CAMERA SECTION ADJUSTMENT

    LCD SYSTEM ADJUSTMENT

    COLOR ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT

    CAMERA SYSTEM ADJUSTMENTS

    INITIALIZATION OF 8,9,A,B,C,D,E,F,13,14,18,19,1A,1B,1C,1D,1E,1F PAGE DATA

    PREPARATIONS BEFORE ADJUSTMENT (CAMERA SECTION)

    LCD SYSTEM ADJUSTMENT

    COLOR ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT

    CAMERA SYSTEM ADJUSTMENTS

    INITIALIZATION OF 8,9,A,B,C,D,E,F,13,14,18,19,1A,1B,1C,1D,1E,1F PAGE DATA

    PREPARATIONS BEFORE ADJUSTMENT (CAMERA SECTION)

    CAMERA SECTION ADJUSTMENT

    TAPE PATH ADJUSTMENT

    HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE

    HOW TO ENTER RECORD MODE WITHOUT CASSETTE

    MECHANISM SECTION ADJUSTMENT

    TAPE PATH ADJUSTMENT

    HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE

    HOW TO ENTER RECORD MODE WITHOUT CASSETTE

    MECHANISM SECTION ADJUSTMENT

    AUDIO SYSTEM ADJUSTMENTS

    VIDEO SYSTEM ADJUSTMENTS

    SERVO AND RF SYSTEM ADJUSTMENT

    SYSTEM CONTROL SYSTEM ADJUSTMENT

    PREPARATIONS BEFORE ADJUSTMENTS

    VIDEO SECTION ADJUSTMENT

    AUDIO SYSTEM ADJUSTMENTS

    VIDEO SYSTEM ADJUSTMENTS

    SERVO AND RF SYSTEM ADJUSTMENT

    SYSTEM CONTROL SYSTEM ADJUSTMENT

    PREPARATIONS BEFORE ADJUSTMENTS

    VIDEO SECTION ADJUSTMENT

    SERVICE MODE

    DATA PROCESS

    ADJUSTMENT REMOTE COMMANDER

    SERVICE MODE

    SERVICE MODE

    DATA PROCESS

    ADJUSTMENT REMOTE COMMANDER

    SERVICE MODE

    How to useAcrobat Reader

    How to useAcrobat Reader

    Sony EMCS Co.2007I0800-1

    2007.09Published by Kohda TEC9-876-770-51

    Contents of LEVEL 2 and LEVEL 3 Service ManualCONTENTS

    1. SERVICE NOTE2. DISASSEMBLY3. BLOCK DIAGRAMS

    4. PRINTED WIRING BOARDSANDSCHEMATIC DIAGRAMS

    5. REPAIR PARTS LIST

    LEVEL 2a

    a

    OVERALLPOWERCK-143, FK-090, IF-122, JK-274, LB-106,MA-431, MK-017, MR-048, PD-222, SE-150,SW-433, VA-119 BOARDFP-228, FP-467, FP-826, FP-959, FP-961,FP-962, FP-963, FP-964, FP-965, FP-966,FP-967, FP-971, FP-972, FP-974, FP-975,FP-976, FP-977, FP-980, FP-981 FLEXIBLECONTROL SWITCH BLOCK (CF5610,PS5610, VS-5610, ZS-5610)EXPLODED VIEWSELECTRICAL PARTS

    LEVEL 3

    CD-522, DA-033, DB-018, VC-367 BOARD

    a (CD-522, DA-033, DB-018, VC-367 BOARD)

    HDR-FX1/FX1E

    HDR-FX1/FX1ERMT-840

  • 2 HDR-FX1/FX1E

    TABLE OF CONTENTS1. Before starting adjustment 6-11-1. Adjusting items when replacing main parts and boards. 6-26-1. CAMERA SECTION ADJUSTMENT 6-41-1. PREPARATIONS BEFORE ADJUSTMENT

    (CAMERA SECTION) 6-41-1-1.List of Service Tools 6-41-1-2.Preparations 6-51-1-3.Precaution 6-71. Setting the Switch 6-72. Order of Adjustments 6-73. Subjects 6-71-2. INITIALIZATION OF 8, 9, A, B, C, D, E, F, 13, 14, 18,

    19, 1A, 1B, 1C, 1D, 1E, 1F PAGE DATA 6-81-2-1. INITIALIZATION OF A, B, D, 1A, 1B PAGE DATA 6-81. Initializing the A, B, D, 1A, 1B Page Data 6-82. Modification of A, B, D, 1A, 1B Page Data 6-83. A Page Table 6-84. B Page Table 6-95. D Page Table 6-96. 1A Page Table 6-97. 1B Page Table 6-91-2-2. INITIALIZATION OF 8, C, 13, 18, 1C PAGE DATA 6-101. Initializing the 8, C, 13, 18, 1C Page Data 6-102. Modification of 8, C, 13, 18, 1C Page Data 6-103. 8 Page Table 6-114. C Page Table 6-115. 13 Page Table 6-126. 18 Page Table 6-127. 1C Page Table 6-121-2-3. INITIALIZATION OF 9, 1D PAGE DATA 6-131. Initializing the 9, 1D Page Data 6-132. Modification of 9, 1D Page Data 6-133. 9 Page Table 6-134. 1D Page Table 6-131-2-4. INITIALIZATION OF E, F, 14, 19, 1E, 1F PAGE DATA 6-141. Initializing the E, F, 14, 19, 1E, 1F Page Data 6-142. Modification of E, F, 14, 19, 1E, 1F Page Data 6-143. E Page Table 6-144. F Page Table 6-155. 14 Page Table 6-166. 19 Page Table 6-177. 1E Page Table 6-178. 1F Page Table 6-181-3. CAMERA SYSTEM ADJUSTMENTS 6-191. Origin Oscillation Check (VC-367 board) 6-192. HALL Adjustment 6-203. MR Adjustment 6-214. Focus Ring Adjustment 6-225. Zoom Ring Adjustment (1) 6-226. Zoom Ring Adjustment (2) 6-237. Flange Back Adjustment (Using Minipattern Box or Flange

    Back Adjustment Jig) 6-248. Flange Back Adjustment (Using Flange Back Adjustment

    Chart and Subject More Than 500m Away) 6-258-1. Flange Back Adjustment (1) 6-258-2. Flange Back Adjustment (2) 6-259. Flange Back Check 6-2610. Picture Frame Setting 6-2711. Auto White Balance Standard Data Input ND OFF 6-2812. Auto White Balance Standard Data Input ND 1 6-2813. Auto White Balance Standard Data Input ND 2 6-2914. MAX GAIN Adjustment 6-2915. LV Standard Data Input 6-3016. Auto White Balance Adjustment ND OFF 6-3017. Auto White Balance Adjustment ND 1 6-3118. Auto White Balance Adjustment ND 2 6-3119. Color Reproduction Adjustment ND OFF 6-3220. Color Reproduction Adjustment ND 1 6-33

    21. Color Reproduction Adjustment ND 2 6-3322. White Balance Check ND OFF 6-3423. White Balance Check ND 1 6-3524. White Balance Check ND 2 6-3625. Color Reproduction Check ND OFF HD STD 6-3726. Color Reproduction Check ND 1 HD STD 6-3827. Color Reproduction Check ND 2 HD STD 6-3828. Color Reproduction Check

    ND OFF HD CINE 6-3929. Color Reproduction Check ND 1 HD CINE 6-4030. Color Reproduction Check ND 2 HD CINE 6-4031. Color Reproduction Check

    ND OFF SD STD 6-4132. Color Reproduction Check ND 1 SD STD 6-4233. Color Reproduction Check ND 2 SD STD 6-4234. Color Reproduction Check ND OFF SD CINE 6-4335. Color Reproduction Check ND 1 SD CINE 6-4436. Color Reproduction Check ND 2 SD CINE 6-4437. PSD Sensor Gain Adjustment 6-4537-1. PSD Sensor Gain Adjustment (1) 6-4537-2. PSD Sensor Gain Adjustment (2) 6-4638. Angular Velocity Sensor Sensitivity Adjustment 6-471-4. COLOR ELECTRONIC VIEWFINDER SYSTEM

    ADJUSTMENT 6-481. VCO Adjustment (VC-367 board) 6-482. Backlight Adjustment (VC-367 board) 6-493. PSIG Level Adjustment (VC-367 board) 6-494. VCOM Level Adjustment (VC-367 board) 6-505. RGB AMP Adjustment (VC-367 board) 6-506. Contrast Adjustment (VC-367 board) 6-517. White Balance Adjustment (VC-367 board) 6-511-5. LCD SYSTEM ADJUSTMENT 6-521. LCD Automatic Adjustment (PD-222 board) 6-522. Contrast Adjustment (HD) (PD-222 board) 6-533. V COM Adjustment (PD-222 board) 6-534. Sample Hold Phase Adjustment (PD-222 board) 6-545. Transmissive Mode White Balance Adjustment

    (PD-222 board) 6-546. Reflective Mode White Balance Adjustment

    (PD-222 board) 6-556-2. MECHANISM SECTION ADJUSTMENT 6-562-1. HOW TO ENTER RECORD MODE WITHOUT

    CASSETTE 6-562-2. HOW TO ENTER PLAYBACK MODE WITHOUT

    CASSETTE 6-562-3. TAPE PATH ADJUSTMENT 6-561. Preparation for Adjustment 6-562. Processing after Completing Operations: 6-566-3. VIDEO SECTION ADJUSTMENT 6-573-1. PREPARATIONS BEFORE ADJUSTMENTS 6-573-1-1.Equipment to Required 6-573-1-2.Precautions on Adjusting 6-583-1-3.Adjusting Connectors 6-593-1-4.Connecting the Equipment 6-593-1-5.Alignment Tapes 6-603-1-6. Input/Output Level and Impedance 6-603-2. SYSTEM CONTROL SYSTEM ADJUSTMENT 6-611. Initialization of 8, 9, A, B, C, D, E, F, 13, 14, 18, 19, 1A,

    1B, 1C, 1D, 1E, 1F Page Data 6-612. Serial No. Input 6-613-3. SERVO AND RF SYSTEM ADJUSTMENT 6-631. Cap FG Duty Adjustment (VC-367 Board) 6-632. Switching Position Adjustment (VC-367 Board) 6-633. Error Rate Check 6-643-1. Preparations before adjustments 6-643-2. Error Rate Check 6-643-3. Processing after Completing Adjustments 6-643-4. VIDEO SYSTEM ADJUSTMENTS 6-65

  • 3 HDR-FX1/FX1E

    * Color reproduction frame is shown on page 6-79.

    1. S VIDEO OUT Y Level Adjustment (VC-367 Board) 6-652. S VIDEO OUT Chroma Level Adjustment

    (VC-367 Board) 6-653. VIDEO OUT Y, Chroma Level Check (VC-367 Board) 6-664. COMPONENT OUTPUT Level Adjustment

    (VC-367 Board) 6-673-5. AUDIO SYSTEM ADJUSTMENTS 6-681. Playback Level Check 6-692. Overall Level Characteristics Check 6-693. Camera E-E Audio Level Check (1) 6-694. Camera E-E Audio Level Check (2) 6-696-4. SERVICE MODE 6-704-1. ADJUSTMENT REMOTE COMMANDER 6-701. Using the adjustment remote commander 6-702. Precautions upon using 6-70

    the adjustment remote commander 6-704-2. DATA PROCESS 6-714-3. SERVICE MODE 6-721. Setting the Test Mode 6-722. Emergence Memory Address (Mechanism section) 6-722-1. EMG Code (Emergency Code) 6-722-2. MSW Code 6-733. Bit value discrimination 6-744. Switch check (1) 6-745. Switch check (2) 6-746. Switch check (3) 6-747. Switch check (4) 6-758. Switch check (5) 6-759. LED check 6-7610. Record of Use check (1) 6-7611. Record of Use check (2) 6-7612. Record of Self-diagnosis check 6-77SELF-DIAGNOSIS CODE TABLE 6-78

  • 6-1

    6. ADJUSTMENTS

    HDR-FX1/FX1E

    1. Before starting adjustmentEVR Data Re-writing Procedure When Replacing BoardThe data that is stored in the repair board, is not necessarily correct.Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

    Procedure 1Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a boardis replaced.

    Remove the EEPROM and install it.

    (Former board) (New board)

    (Machine to be repaired) (Machine to be repaired)

    (The same model of the same destination)

    Save the data.

    Download the data.

    PC

    Procedure 2Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROMto the replaced board.

    Procedure 3When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed orinstalled, save the data from the same model of the same destination, and download it.

    After the EVR data is saved and downloaded, check therespective items of the EVR data.(Refer to page 6-3 for the items to be checked.)

    (Machine before starting repair) (Machine after a board is replaced)PC PC

    Save the EVR data to a personal computer.

    Download the saved data to a machine.

    Note: IC8001 (Flash memory) onthe VC-367 board cannot bereplaced.

  • 6-2HDR-FX1/FX1E

    Lens

    devic

    eM

    echa

    nism

    deck

    (Note

    )LC

    D blo

    ck LC

    D901

    (LCD

    panel

    l)LC

    D blo

    ck Ba

    cklig

    ht LE

    DEV

    F bloc

    k LCD

    902 (L

    CD pa

    nel)

    Mec

    hanis

    m de

    ck M

    901 (D

    rum ass

    y) Note

    Mec

    hanis

    m MD

    bloc

    kPR

    ISM as

    sy (CD

    -522 b

    oard I

    C101

    to 103)

    CD-52

    2 boa

    rd IC

    104 t

    o 106

    (S/H)

    LB-10

    6 boa

    rd D

    501 (b

    ackligh

    t (EVF

    ))M

    R-04

    8 boa

    rd IC

    0101

    (REC

    /PB AM

    P)PD

    -222 b

    oard

    IC60

    1 (RGB

    drive

    r, Tim

    ing ge

    nerato

    r (LCD

    ))SE

    -150 b

    oard

    SE40

    1/402

    (PITC

    H /YA

    W se

    nsor)

    VA-11

    9 boa

    rd IC

    2201

    (Vide

    o IN/

    OUT)

    VC-36

    7 boar

    d IC

    1101

    , X11

    01, X

    1102

    (Tim

    ing ge

    nerat

    or)VC

    -367 b

    oard

    IC11

    04 to

    1106

    (AGC

    , A/D

    conv.

    )VC

    -367 b

    oard

    IC20

    21 (B

    ase ba

    nd pro

    cess, e

    tc.)VC

    -367 b

    oard

    IC40

    01 (D

    V sig

    nal pr

    oces

    s,RF s

    ignal p

    roces

    s)VC

    -367 b

    oard

    IC60

    01 (R

    GB dri

    ver (E

    VF))

    VC-36

    7 boa

    rd IC

    6002

    (Tim

    ing ge

    nera

    tor (E

    VF))

    Replaced partsBlock replacement Parts replacement

    z

    z

    z

    z

    z

    z z

    z z z

    z z z

    z z z

    z z z

    z z z

    z

    z z

    z z

    z

    z

    z

    z

    z z

    z z z

    z z

    z z z

    z z

    z z

    z z z

    z z z

    z z z

    z z

    z z z

    z z z z z

    z z

    z z

    z

    AdjustmentSection

    Initialization of8,9,A,B,C,D,E,F,13,14,18,19,1A,1B,1C,1D,1E,1F page data

    Camera

    Color EVF

    LCD

    MechanismSystem control

    Servo, RF

    Video

    Adjustment

    Initialization of A, B, D, 1A,1B page dataInitialization of 8, C, 13, 18, 1C page dataInitialization of 9, 1D page dataInitialization of E, F, 14, 19, 1E, 1F page dataOrigin oscillation checkHALL adj.MR adj.Focus ring adj.Zoom ring adj.Flange back adj.AWB standard data inputMAX GAIN adj.LV standard data inputAuto white balance adj.Color reproduction adj.PSD sensor gain adj.Angular velocity sensor sensitivity adj.VCO adj.Backlight adj.PSIG level adj.VCOM level adj.RGB AMP adj.Contrast adj.White balance adj.LCD automatic adj.Contrast adj.(HD)V COM adj.Sample hold phase adj.Transmissive mode white balance adj.Reflective mode white balance adj.Tape path adj.Serial No. inputCAP FG duty adj.Switching position adj.Error rate checkS VIDEO OUT Y level adj.S VIDEO OUT chroma level adj.COMPONENT OUTPUT level adj.

    1-1. Adjusting items when replacing main parts and boards. Adjusting items when replacing main partsWhen replacing main parts, adjust the items indicated by z in the following table.Note: When replacing the drum assy. or the mechanism deck, reset the data of page: 7, address: A7 to A9 to 00. (Refer to Record of Use check of

    6-4. SERVICE MODE)

    Table. 6-1-1(1).

  • 6-3HDR-FX1/FX1E

    CD-52

    2 boa

    rd (CO

    MPLE

    AT)

    LB-10

    6 boa

    rd (CO

    MPLE

    AT)

    MR-

    048 b

    oard

    (COMP

    LEAT

    )PD

    -222 b

    oard

    (COMP

    LEAT

    )SE

    -150 b

    oard

    (COMP

    LEAT

    )VA

    -119 b

    oard

    (COMP

    LEAT

    )VC

    -367 b

    oard

    (COMP

    LEAT

    )VC

    -367 b

    oard

    IC19

    01 (E

    EPRO

    M)VC

    -367 b

    oard

    IC88

    02 (E

    EPRO

    M)VC

    -367 b

    oard

    IC80

    02 (E

    EPRO

    M)Su

    ppor

    ting

    Board EEPROMreplacement replacement

    z z

    z z

    z z

    z z

    z

    z z z

    z z z

    z z z

    z z z

    z z z z

    z z z z

    z z z z

    z z z z

    z z z z

    z z z z

    z z

    z z z

    z z

    z z

    z z

    z z

    z z

    z z

    z z z

    z z z z

    z z z z

    z z z

    z z z

    z z z

    z z z z

    z z

    z z

    z z z z

    z z z z

    z z z z

    z z z

    z z z

    z z

    Table. 6-1-1(2).

    Adjusting items when replacing a board or EEPROMWhen replacing a board or EEPROM, adjust the items indicated by z in the following table.

    AdjustmentSection

    Initialization of8,9,A,B,C,D,E,F,13,14,18,19,1A,1B,1C,1D,1E,1F page data

    Camera

    Color EVF

    LCD

    MechanismSystem control

    Servo, RF

    Video

    Adjustment

    Initialization of A, B, D, 1A,1B page dataInitialization of 8, C, 13, 18, 1C page dataInitialization of 9, 1D page dataInitialization of E, F, 14, 19, 1E, 1F page dataOrigin oscillation checkHALL adj.MR adj.Focus ring adj.Zoom ring adj.Flange back adj.AWB standard data inputMAX GAIN adj.LV standard data inputAuto white balance adj.Color reproduction adj.PSD sensor gain adj.Angular velocity sensor sensitivity adj.VCO adj.Backlight adj.PSIG level adj.VCOM level adj.RGB AMP adj.Contrast adj.White balance adj.LCD automatic adj.Contrast adj.(HD)V COM adj.Sample hold phase adj.Transmissive mode white balance adj.Reflective mode white balance adj.Tape path adj.Serial No. inputCAP FG duty adj.Switching position adj.Error rate checkS VIDEO OUT Y level adj.S VIDEO OUT chroma level adj.COMPONENT OUTPUT level adj.

  • 6-4HDR-FX1/FX1E

    6-1. CAMERA SECTION ADJUSTMENT

    1-1. PREPARATIONS BEFORE ADJUSTMENT (CAMERA SECTION)1-1-1. List of Service Tools Oscilloscope Color monitor Vector scope

    Fig. 6-1-1.

    J-1 J-2 J-3

    Filter for colortemperaturecorrection (C14)J-6080-058-A

    ND filter 1.0J-6080-808-AND filter 0.4J-6080-806-A

    ND filter 0.1J-6080-807-A

    Pattern box PTB-450J-6082-200-AorPattern box PTB-1450J-6082-557-A

    Color chart forpattern box

    For PTB-450:J-6020-250-AFor PTB-1450:J-6082-559-A

    Siemens star chartJ-6080-875-A

    Clear chart forpattern box

    For PTB-450:J-6080-621-A

    For PTB-1450:J-6082-560-A

    Mini pattern boxJ-6082-353-B

    Adjustment remotecommander(RM-95 upgraded)J-6082-053-B

    Camera tableJ-6082-384-A

    Extension cable(28P 0.8mm)J-6082-566-A

    J-4 J-5 J-6

    J-7 J-8 J-9

    J-10 J-11 J-12

    CPC-8 jigJ-6082-388-A

    Flange backadjustment jigJ-6082-563-A

    Ver 1.2 2005. 09

  • 6-5HDR-FX1/FX1E

    1-1-2. PreparationsNote1: For details of how remove the cabinet and boards, refer to 2.

    DISASSEMBLY.Note2: When performing only the adjustments, the lens block and boards

    need not be disassembled.Note3: Before performing the adjustments, check the data of page: 0,

    address: 10 is 00. If not, set data: 00 to this address.

    1) Connect the equipment for adjustments according to Fig. 6-1-3.

    Note4: As removing the FP-959 board (removing CN207 of the DB-018board) means removing the lithium 3V power supply (BT591 onthe FP-959 board), data such as date, time, user-set menus will belost. After completing adjustments, reset these data.But the self-diagnosis data and the data on history of use (totaldrum rotation time etc.) will be kept even if the lithium 3V powersupply is removed. (Refer to 6-4. Service Mode for the self-diagnosis data and the data on history of use.)

    Note5: Setting the Forced Camera Power ON Mode1) Select page: 0, address: 01, and set data: 01.2) Select page: A, address: 10, set data: 01, and press the PAUSE

    button.The above procedure will enable the camera power to be turnedon with the control key block (PS5610) removed. After completingadjustments, be sure to exit the Forced Camera Power ON Mode.(Operate the camera functions using the touch panel. When thecontrol key block (PS5610) is removed, the function buttons ofthe adjustment remote commander are not effective even if theHOLD switch of the adjustment remote commander is set to theOFF position.)

    Note6: Exiting the Forced Camera Power ON Mode1) Select page: 0, address: 01, and set data: 01.2) Select page: A, address: 10, set data: 00, and press the PAUSE

    button.3) Select page: 0, address: 01, and set data: 00.

    Fig. 6-1-2.

    Front of the lens

    Pattern box

    100 cm (PTB-450)40 cm (PTB-1450)

  • 6-6HDR-FX1/FX1E

    Fig. 6-1-3.

    Adjustment remotecommander (RM-95)

    LANC jack

    AC poweradaptor

    AC IN

    DC-IN

    Screw (M2x4)

    CPC lid

    CPC-8 jig(J-6082-388-A)

    [CONNECTION OF EQUIPMENT]

  • 6-7HDR-FX1/FX1E

    White

    Black

    841mm

    1189mm

    1-1-3. Precaution1. Setting the SwitchUnless otherwise specified, set the switches as follows and perform adjustments without loading cassette.

    1. POWER switch (PS5610 block) ............................ CAMERA2. FOCUS switch (CK-143 block) ............................ MANUAL3. ND FILTER switch (Lens block) .....................................OFF4. ZOOM RING/LEVER switch (Lens block) .............. LEVER5. AUTO LOCK switch (FP-966 flexible) ............................ ON6. BACK LIGHT switch (FP-961 flexible) ..........................OFF7. SPOT LIGHT switch (FP-961 flexible) ...........................OFF8. BARS switch (FK-090 board) ..........................................OFF9. ZEBRA switch (MK-017 board) .....................................OFF

    10. MENU settingsCAMERA SET menuSTEADY SHOT .......................................................OFF

    IN/OUT REC. menuREC FORMAT .............................................. HDV1080iCOMPONENT ....................................................... 1080iTV TYPE .................................................................. 16:9

    2. Order of AdjustmentsBasically carry out adjustments in the order given.

    Fig.6-1-4.

    3. Subjects1) Color bar chart (HD color bar standard picture frame)

    When performing adjustments using the color bar chart, adjustthe picture frame as shown in Fig. 6-1-4. (Color reproductionadjustment frame)

    2) Clear chart (HD color bar standard picture frame)Remove the color bar chart from the pattern box and insert aclear chart in its place. (Do not perform zoom operations duringthis time.)

    3) Flange back adjustment chartMake the chart shown in Fig. 6-1-5 using A0 size (1189mm 841mm) black and white vellum paper.

    Electronic beam scanning frame

    CRT picture frame

    Yello

    w

    Gre

    enW

    hite

    Mag

    enta

    Red

    Blue

    H

    A=B

    C=0, D=0

    BB AA

    Cyan

    Red

    Yello

    w

    Cyan

    Gre

    enW

    hite

    Mag

    enta

    Blue

    Difference in level

    Enrargement

    AB

    C D

    V

    Color bar chart (HD color bar standard picture frame)

    Fig. a(Component output terminalY signal output waveform)

    Fig. b (HD TV monitor picture)

    Adjust the camera zoom and direction to obtainthe output waveform shown in Fig. a and theHD TV monitor display shown in Fig. b.

    Fig. 6-1-5.

    Note: Use matte vellum paper bigger than A0, and make sure the edges ofthe black and white paper joined together are not rough.

  • 6-8HDR-FX1/FX1E

    1-2. INITIALIZATION OF 8, 9, A, B, C, D, E, F, 13,14, 18, 19, 1A, 1B, 1C, 1D, 1E, 1F PAGE DATA

    Note: When reading or writing the 13, 14, 18, 19, 1A, 1B, 1C, 1D, 1E, 1Fpage data, select page: 0, address: 10, and set data: 01, then select 3,4, 8, 9, A, B, C, D, E or F page. The 13, 14, 18, 19, 1A, 1B, 1C, 1D,1E or 1F page can be chosen by this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    1-2-1. INITIALIZATION OF A, B, D, 1A, 1B PAGE DATANote: When reading or writing the A, B, D page data, select page: 0,

    address: 10, and set data: 00.When reading or writing the 1A or 1B page data, select page: 0,address: 10, and set data: 01, then select A or B page. The 1A or 1Bpage can be chosen by this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    1. Initializing the A, B, D, 1A, 1B Page DataNote1: If the A, B, D, 1A, 1B page data has been initialized, the following

    adjustments need to be performed again.1) Modification of A, B, D, 1A, 1B page data

    Adjusting page AAdjusting Address 10 to FFAdjusting page BAdjusting Address 00 to FFAdjusting page DAdjusting Address 10 to 7AAdjusting page 1AAdjusting Address 00 to FFAdjusting page 1BAdjusting Address 00 to FF

    Initializing Method:Order Page Address Data Procedure1 0 01 01 Set the data.2 0 10 00 Set the data.3 7 04 Set the following data.

    00 (HDR-FX1 (NTSC))01 (HDR-FX1E (PAL))

    4 7 01 XX Set the data. (Note2)5 7 00 01 Set the data, and press PAUSE

    button. (Note2)6 7 02 Check that the data changes to

    017 Perform Modification of A, B,

    D, 1A, 1B Page Data.

    Note2: XX=20: Initializing A pageXX=21: Initializing B pageXX=22: Initializing D pageXX=23: Initializing 1A pageXX=24: Initializing 1B pageXX=25: Initializing A and 1A pageXX=26: Initializing B and 1B pageXX=28: Initializing A, B, D, 1A and 1B page

    2. Modification of A, B, D, 1A, 1B Page DataIf the A, B, D, 1A, 1B page data has been initialized, change thedata of the Fixed data-2 address shown in the following tables bymanual input.

    Modifying Method:1) Before changing the data, select page: 0, address: 01, and set

    data: 01.2) When changing the A, B, D page data, select page: 0, address:

    10, and set data: 00.3) When changing the 1A, 1B page data, select page: 0, address:

    10, and set data: 01.After completing the modification of 1A, 1B page data, resetthe data of this address to 00.

    4) New data for changing are not shown in the tables becausethey are different in destination. When changing the data, copythe data built in the same model.Note: If copy the data built in the different model, the camcorder may

    not operate.5) When changing the data, press the PAUSE button of the

    adjustment remote commander each time when setting newdata to write the data in the non-volatile memory.

    Processing after Completing Modification of A, B, D, 1A, 1B Page dataOrder Page Address Data Procedure1 0 10 00 Set the data.2 2 00 29 Set the data.3 2 01 29 Set the data, and press PAUSE

    button.

    Note: If the following symptoms occur after completing of theModification of A, B, D, 1A, 1B page data, check that the data ofaddresses: 1A to 4F of A page and the data of addresses: 12 to 19 ofD page are same as those of the same model of the same destination.1) The self-diagnosis code E:20:00 on the LCD screen is displayed.2) The power is shut off so that unit cannot operate.

    3. A Page TableNote1: The data of page: 0, address: 10 must be 00.Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the A, B,

    D, 1A, 1B Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of A, B,D, 1A, 1B Page Data).

    Address RemarkInitial valueAddress RemarkInitial value00 to 0F

    1011 to 17

    1819 to 2E

    2F3031

    32 to FF

    00 Test modeFixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1

    Table. 6-1-2.

  • 6-9HDR-FX1/FX1E

    4. B Page TableNote1: The data of page: 0, address: 10 must be 00.Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the A, B,

    D, 1A, 1B Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of A, B,D, 1A, 1B Page Data).

    Table. 6-1-3.

    5. D Page TableNote1: The data of page: 0, address: 10 must be 00.Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the A, B,

    D, 1A, 1B Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of A, B,D, 1A, 1B Page Data).

    Address00 to FF

    RemarkFixed data-1

    Address00 to 0F10 to 15

    1617 to 27

    28292A2B2C2D2E2F30

    31 to 3233

    34 to 5657

    58 to 797A

    Remark

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2

    6. 1A Page TableNote1: When reading or writing the 1A page data, select page: 0, address:

    10, and set data: 01, then select A page. The 1A page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the A, B,D, 1A, 1B Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of A, B,D, 1A, 1B Page Data).

    Address00 to C4

    C5C6 to CE

    CFD0 to D3

    D4D5D6

    D7 to D8D9

    DA to D0DE

    DF to E2E3

    E4 to ECED

    EE to F1F2F3F4

    F5 to F6F7

    F8 to FBFC

    FD to FF

    RemarkFixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1

    Table. 6-1-5.

    7. 1B Page TableNote1: When reading or writing the 1B page data, select page: 0, address:

    10, and set data: 01, then select B page. The 1B page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the A, B,D, 1A, 1B Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of A, B,D, 1A, 1B Page Data).

    Table. 6-1-6.

    Address00 to FF

    RemarkFixed data-1

    Table. 6-1-4.

  • 6-10HDR-FX1/FX1E

    2. Modification of 8, C, 13, 18, 1C Page DataIf the 8, C, 13, 18, 1C page data has been initialized, change thedata of the Fixed data-2 address shown in the following table bymanual input.

    Modifying Method:1) Before changing the data, select page: 0, address: 01, and set

    data: 01.2) When changing the 8, C page data, select page: 0, address: 10,

    and set data: 00.3) When changing the 13, 18, 1C page data, select page: 0, address:

    10, and set data: 01.After completing the modification of 13, 18, 1C page data,reset the data of this address to 00.

    4) New data for changing are not shown in the tables becausethey are different in destination. When changing the data, copythe data built in the same model.Note: If copy the data built in the different model, the camcorder may

    not operate.5) When changing the data, press the PAUSE button of the

    adjustment remote commander each time when setting newdata to write the data in the non-volatile memory.

    6) Check that the data of adjustment addresses is the initial value.If not, change the data to the initial value.

    Processing after Completing Modification of 8, C, 13, 18, 1C Page dataOrder Page Address Data Procedure1 0 10 00 Set the data.2 2 00 29 Set the data.3 2 01 29 Set the data, and press PAUSE

    button.

    Version check of the mechanism control microprocessor:(VC-367 board IC8801)Order Page Address Data Procedure1 0 10 00 Set the data.2 3 FF The data shows the version of

    the mechanism controlmicroprocessor.10: Ver. 1.0 (MP1)20: Ver. 2.0 (MP2)

    Note: For PAL model, the S VIDEO OUT Y/chroma level adjustmentaddresses are changed by the version of the mechanism controlmicroprocessor. (Refer to 4. C Page Table.)

    1-2-2. INITIALIZATION OF 8, C, 13, 18, 1C PAGE DATANote1: When reading or writing the 8, C page data, select page: 0, address:

    10, and set data: 00.When reading or writing the 13, 18, 1C page data, select page: 0,address: 10, and set data: 01, then select 3, 8 or C page. The 13, 18or 1C page can be chosen by this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: NTSC model: HDR-FX1PAL model: HDR-FX1E

    1. Initializing the 8, C, 13, 18, 1C Page DataNote1: If Initializing the 8, C, 13, 18, 1C Page Data is performed, all

    data of the 8 page, C page, 13 page, 18 page and 1C page will beinitialized. (It is impossible to initialize a single page.)

    Note2: If the 8, C, 13, 18, 1C page data has been initialized, followingadjustments need to be performed again.1) Modification of 8, C, 13, 18, 1C page data2) Viewfinder system adjustments3) LCD system adjustments4) Serial No. input5) Servo and RF system adjustments6) Video system adjustments

    Note3: NTSC model: HDR-FX1PAL model: HDR-FX1E

    Adjusting page 8Adjusting Address 00 to FFAdjusting page CAdjusting Address 10 to FFAdjusting page 13Adjusting Address 00 to FFAdjusting page 18Adjusting Address 00 to FFAdjusting page 1CAdjusting Address 00 to FF

    Initializing Method:Order Page Address Data Procedure1 0 01 01 Set the data.2 0 10 00 Set the data.3 3 81 00 Set the data.4 3 80 0C Set the data, and press PAUSE

    button.5 3 80 Check that the data changes to

    1C.6 Perform Modification of 8, C,

    13, 18, 1C Page Data.

  • 6-11HDR-FX1/FX1E

    3. 8 Page TableNote1: The data of page: 0, address: 10 must be 00.Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,

    13, 18, 1C Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,13, 18, 1C Page Data).

    Address00 to 7D

    7E7F to 83

    8485 to 9C

    9D9E9FA0A1A2A3A4A5A6A7A8

    A9 to ACAD

    AE to B0B1B2B3B4B5B6B7B8B9BABBBCBD

    BE to BFC0C1C2C3C4C5

    C6 to C7C8C9CACBCCCDCECFD0D1D2D3

    D4 to FF

    RemarkFixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2

    Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Table. 6-1-6.

    4. C Page TableNote1: The data of page: 0, address: 10 must be 00.Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,

    13, 18, 1C Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,13, 18, 1C Page Data).

    Note3: PAL model with the version 1.0 mechanism controlmicroprocessor, or NTSC model.

    Note4: PAL model with the version 2.0 mechanism controlmicroprocessor. (Refer to 2. Modification of 8, C, 13, 18, 1CPage Data for version check of the mechanism controlmicroprocessor (VC-367 board IC8801).).

    Initial valueNTSC PAL

    00 to 0F10111213

    14 to 1516

    17 to 24252627

    28 to 3032333435363738393A3B3C

    3D to 4445464748

    49 to 4A4B4C4D

    4D to 5051525354

    55 to 68696A

    6B to 6D6E6F7071

    Switching position adj.

    Fixed data-1CAP FG duty adj.Fixed data-1S VIDEO out Y level adj. (Note3)S VIDEO out chroma level adj.(Note3)Fixed data-1Backlight adj. (EVF)

    VCO adj. (EVF)

    VCOM level adj. (EVF)RGB AMP adj. (EVF)Fixed data-1PSIG level adj. (EVF)White balance adj. (EVF)

    Contrast adj. (EVF)Fixed data-1VCO adj. (LCD)

    V COM adj. (LCD)RGB AMP adj. (LCD)Fixed data-1Transmissive mode white balanceadj. (LCD)Contrast adj. (SD) (LCD)Fixed data-1Fixed data-2

    Fixed data-1Sample hold phase adj. (LCD)Fixed data-1Fixed data-2

    Fixed data-1Fixed data-2

    Reflective mode white balance adj.(LCD)

    Address RemarkInitial value

    EE000000

    E0

    702A2A

    539D30592A8E

    4E808018

    80809A88

    808031

    7F

    8080

    EE000000

    E0

    702A2A

    539D30592A8E

    4E808018

    80809A88

    808031

    7F

    8080

  • 6-12HDR-FX1/FX1E

    Initial valueNTSC PAL

    Address RemarkInitial value

    Table. 6-1-7.

    5. 13 Page TableNote1: When reading or writing the 13 page data, select page: 0, address:

    10, and set data: 01, then select 8 page. The 13 page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,13, 18, 1C Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,13, 18, 1C Page Data).

    Address RemarkInitial valueAddress RemarkInitial value00 to 0F

    0405060708090A0B

    0C to 1213

    14 to 2425

    26 to FF

    0800460102000000

    Serial No. input

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1

    C page

    7273

    74 to 757677

    78 to 81828384858687

    88 to F3F4F5F6F7F8F9FAFBFCFDFEFF

    3118

    753636702A2A

    000000000000000000000000

    3118

    753636702A2A

    000000000000000000000000

    Fixed data-1Fixed data-2Fixed data-1Contrast adj.(HD) (LCD)Contrast adj. (EVF)Fixed data-1COMPONENT OUTPT level adj.

    S VIDEO out Y level adj. (Note4)S VIDEO out chroma level adj.(Note4)Fixed data-1Emergency memory address(Mechanism section)

    Table. 6-1-8.

    6. 18 Page TableNote1: When reading or writing the 18 page data, select page: 0, address:

    10, and set data: 01, then select 8 page. The 18 page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,13, 18, 1C Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,13, 18, 1C Page Data).

    Table. 6-1-9.

    Address00 to 5D

    5E5F to FF

    RemarkFixed data-1Fixed data-2Fixed data-1

    Address RemarkInitial valueAddress RemarkInitial value00 to 42

    4344 to 46

    474849

    4A to 4D4E4F505152535455565758

    59 to 5D5E

    5F to 6667

    68 to 696A

    6B to B2B3B4B5B6B7B8B9BABB

    000000000080000000

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Error rate check

    7. 1C Page TableNote1: When reading or writing the 1C page data, select page: 0, address:

    10, and set data: 01, then select C page. The 1C page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,18, 1C Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,18, 1C Page Data).

  • 6-13HDR-FX1/FX1E

    1-2-3. INITIALIZATION OF 9, 1D PAGE DATANote: When reading or writing the 9 page data, select page: 0, address:

    10, and set data: 00.When reading or writing the 1D page data, select page: 0, address:10, and set data: 01, then select D page. The 1D page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    1. Initializing the 9, 1D Page DataNote1: If Initializing the 9, 1D Page Data is performed, all data of the 9

    page and 1D page will be initialized. (It is impossible to initializea single page.)

    Note2: If the 9, 1D page data has been initialized, following adjustmentsneed to be performed again.1) Modification of 9, 1D page data

    Adjusting page 9Adjusting Address 10 to FFAdjusting page 1DAdjusting Address 00 to FF

    Initializing Method:Order Page Address Data Procedure1 0 01 01 Set the data.2 0 10 00 Set the data.3 3 81 00 Set the data.4 3 80 04 Set the data, and press PAUSE

    button.5 3 80 Check that the data changes to

    14.6 Perform Modification of 9, 1D

    Page Data.

    2. Modification of 9, 1D Page DataIf the 9, 1D page data has been initialized, change the data of theFixed data-2 address shown in the following table by manual input.

    Modifying Method:1) Before changing the data, select page: 0, address: 01, and set

    data: 01.2) When changing the 9 page data, select page: 0, address: 10,

    and set data: 00.3) When changing the 1D page data, select page: 0, address: 10,

    and set data: 01.After completing the modification of 1D page data, reset thedata of this address to 00.

    4) New data for changing are not shown in the tables becausethey are different in destination. When changing the data, copythe data built in the same model.Note: If copy the data built in the different model, the camcorder may

    not operate.5) When changing the data, press the PAUSE button of the

    adjustment remote commander each time when setting newdata to write the data in the non-volatile memory.

    6) Check that the data of adjustment addresses is the initial value.If not, change the data to the initial value.

    Processing after Completing Modification of 9, 1D Page dataOrder Page Address Data Procedure1 0 10 00 Set the data.2 2 00 29 Set the data.3 2 01 29 Set the data, and press PAUSE

    button.

    Address00 to 0F10 to FF

    Remark

    Fixed data-1

    Address00 to FF

    RemarkFixed data-1

    3. 9 Page TableNote1: The data of page: 0, address: 10 must be 00.Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 9, 1D

    Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of 9, 1DPage Data).

    Table. 6-1-11.

    4. 1D Page TableNote1: When reading or writing the 1D page data, select page: 0, address:

    10, and set data: 01, then select D page. The 1D page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: The data of page: 0, address: 10 must be 00.Note3: Fixed data-1: Initialized data. (Refer to 1. Initializing the 9, 1D

    Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of 9, 1DPage Data).

    Table. 6-1-12.

    Address RemarkInitial valueAddress RemarkInitial value

    1C page

    BCBDBEBFC0C1C2C3C4C5C6C7C8

    C9 to FBFC

    FD to FF

    00000000000000800000000000

    Error rate check

    Fixed data-1Fixed data-2Fixed data-1

    Table. 6-1-10.

  • 6-14HDR-FX1/FX1E

    2. Modification of E, F, 14, 19, 1E, 1F Page DataIf the E, F, 14, 19, 1E, 1F page data has been initialized, change thedata of the Fixed data-2 address shown in the following table bymanual input.

    Modifying Method:1) Before changing the data, select page: 0, address: 01, and set

    data: 01.2) When changing the E, F page data, select page: 0, address: 10,

    and set data: 00.3) When changing the 14, 19, 1E, 1F page data, select page: 0,

    address: 10, and set data: 01.After completing the modification of 14, 19, 1E, 1F page data,reset the data of this address to 00.

    1-2-4. INITIALIZATION OF E, F, 14, 19, 1E, 1F PAGE DATANote: When reading or writing the E, F page data, select page: 0, address:

    10, and set data: 00.When reading or writing the 14, 19, 1E and 1F page data, selectpage: 0, address: 10, and set data: 01, then select 4, 9, E or F page.The 14, 19, 1E or 1F page can be chosen by this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    1. Initializing the E, F, 14, 19, 1E, 1F Page DataNote1: If Initializing the E, F, 14, 19, 1E, 1F Page Data is performed,

    all data of the E page, F page, 14 page, 19 page, 1E page and 1Fpage will be initialized. (It is impossible to initialize a single page.)

    Note2: If the E, F, 14, 19, 1E, 1F page data has been initialized, followingadjustments need to be performed again.1) Modification of E, F, 14, 19, 1E, 1F page data2) Camera system adjustments

    Adjusting page EAdjusting Address 00 to FFAdjusting page FAdjusting Address 10 to FFAdjusting page 14Adjusting Address 00 to FFAdjusting page 19Adjusting Address 00 to FFAdjusting page 1EAdjusting Address 00 to E5Adjusting page 1FAdjusting Address 00 to FF

    Initializing Method:Order Page Address Data Procedure1 0 01 01 Set the data.2 0 10 00 Set the data.3 6 01 Set the following data, and press

    PAUSE button.2D: HDR-FX1 (NTSC)2F: HDR-FX1E (PAL)

    4 6 03 01 Set the data, and press PAUSEbutton.

    5 6 02 Check that the data changes to01.

    6 6 01 00 Set the data, and press PAUSEbutton.

    7 Perform Modification of E, F,14, 19, 1E, 1F Page Data.

    Address00 to 17

    18191A1B1C1D1E

    1F to 5859

    5A to 6465666768696A

    6B to 80818283

    84 to 9091

    92 to D3D4D5

    D6 to D8D9

    DA to FF

    RemarkFixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2

    Fixed data-1Fixed data-2Fixed data-1

    4) New data for changing are not shown in the tables becausethey are different in destination. When changing the data, copythe data built in the same model.Note: If copy the data built in the different model, the camcorder may

    not operate.5) When changing the data, press the PAUSE button of the

    adjustment remote commander each time when setting newdata to write the data in the non-volatile memory.

    6) Check that the data of adjustment addresses is the initial value.If not, change the data to the initial value.

    Processing after Completing Modification of E, F, 14, 19, 1E, 1F Page dataOrder Page Address Data Procedure1 0 10 00 Set the data.2 2 00 29 Set the data.3 2 01 29 Set the data, and press PAUSE

    button.

    3. E Page TableNote1: The data of page: 0, address: 10 must be 00.Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,

    14, 19, 1E, 1F Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of E, F,14, 19, 1E, 1F Page Data).

    Table. 6-1-13.

  • 6-15HDR-FX1/FX1E

    4. F Page TableNote1: The data of page: 0, address: 10 must be 00.Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,

    14, 19, 1E, 1F Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of E, F,14, 19, 1E, 1F Page Data).

    Initial valueNTSC PAL

    00 to 0F10 to 12

    131415161718191A1B

    1C to 2324252627

    28 to 292A2B2C2D

    2E to 3738393A3B3C3D3E3F40414243

    44 to 5F606162636465666768696A6B6C6D6E6F

    Fixed data-1HALL adj.

    Fixed data-1MAX GAIN adj.LV standard data input

    Fixed data-1HALL adj.

    Fixed data-1AWB standard data inputND OFF

    Fixed data-1Color reproduction adj.ND OFF

    Auto white balance adj.

    Auto white balance adj.ND OFF

    Fixed data-1Flange back adj.

    Address RemarkInitial value

    6A4E3B681A

    803580

    8818722E

    19C707F6

    00EF1E2F2BE058780F4B0E34

    117790ED23B600000000CC1919380000

    6A4E3B681A

    803580

    8818722E

    19C707F6

    00EF1E2F2BE058780F4B0E34

    117790ED23B600000000CC1919380000

    Initial valueNTSC PAL

    Address RemarkInitial value

    70

    7172737475767778797A7B7C

    7D to 8384858687

    88 to A5A6A7A8A9

    AA to ABACADAEAFB0B1B2B3B4B5B6B7B8B9BABBBCBDBEBFC0C1C2C3

    00

    8080808040C040C040C040C0

    80805050

    80808080

    00EF1E2F00EF1E2F00EF1E2F00EF1E2F00EF1E2F00EF1E2F

    00

    8080808040C040C040C040C0

    80805050

    80808080

    00EF1E2F00EF1E2F00EF1E2F00EF1E2F00EF1E2F00EF1E2F

    MR adj./Focus ring adj./Zoom ring adj./Flange back adj.MR adj.

    Fixed data-1PSD sensor gain adj.

    Angular velocity sensorsensitivity adj.Fixed data-1Focus ring adj.

    Zoom ring adj. (1)

    Fixed data-1Color reproduction adj. ND 1

    Color reproduction adj. ND 2

    Color reproduction adj. ND OFF

    Color reproduction adj. ND 1

    Color reproduction adj. ND 2

    Color reproduction adj. ND OFF

  • 6-16HDR-FX1/FX1E

    Initial valueNTSC PAL

    Address RemarkInitial value

    Table. 6-1-14.

    5. 14 Page TableNote1: When reading or writing the 14 page data, select page: 0, address:

    10, and set data: 01, then select 4 page. The 14 page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,14, 19, 1E, 1F Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of E, F,14, 19, 1E, 1F Page Data).

    Address00 to FF

    RemarkFixed data-1

    Table. 6-1-15.

    F page

    C4C5C6C7C8C9CACBCCCDCECFD0D1D2D3D4D5D6D7D8D9DADBDCDDDEDFE0E1E2E3E4E5E6E7E8E9EAEBECEDEEEFF0F1F2F3F4

    F5 to FF

    00EF1E2F00EF1E2F19E407F00F4D0DE419AB08300F130E7600EF1E2F00EF1E2F00EF1E2F757211C040C040C040C040C000

    00EF1E2F00EF1E2F19E407F00F4D0DE419AB08300F130E7600EF1E2F00EF1E2F00EF1E2F757211C040C040C040C040C000

    Color reproduction adj. ND 1

    Color reproduction adj. ND 2

    AWB standard data input ND 1

    Auto white balance adj. ND 1

    AWB standard data input ND 2

    Auto white balance adj. ND 2

    Color reproduction adj. ND OFF

    Color reproduction adj. ND 1

    Color reproduction adj. ND 2

    Zoom ring adj. (2)

    Focus ring adj.

    Zoom ring adj. (1)

    Flange back adj.Fixed data-1

  • 6-17HDR-FX1/FX1E

    6. 19 Page TableNote1: When reading or writing the 19 page data, select page: 0, address:

    10, and set data: 01, then select 9 page. The 19 page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,14, 19, 1E, 1F Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of E, F,14, 19, 1E, 1F Page Data).

    Address00 to 696A

    6B to 6D6E6F70

    71 to 78797A7B7C

    7D to 8182

    83 to 8586

    87 to FF

    RemarkFixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1

    Table. 6-1-16.

    Address00 to 74

    757677

    78 to CDCECF

    D0 to FF

    RemarkFixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2

    Fixed data-1

    7. 1E Page TableNote1: When reading or writing the 1E page data, select page: 0, address:

    10, and set data: 01, then select E page. The 1E page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,14, 19, 1E, 1F Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of E, F,14, 19, 1E, 1F Page Data).

    Table. 6-1-17.

  • 6-18HDR-FX1/FX1E

    8. 1F Page TableNote1: When reading or writing the 1F page data, select page: 0, address:

    10, and set data: 01, then select F page. The 1F page can be chosenby this data setting.After reading or writing, reset the data of page: 0, address: 10 to00.

    Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,14, 19, 1E, 1F Page Data.)Fixed data-2: Modified data. (Refer to 2. Modification of E, F,14, 19, 1E, 1F Page Data).

    Address00 to 0D

    0E0F to 10

    1112

    13 to 1516

    17 to 4D4E

    4F to 5051525354

    55 to D5D6D7

    D8 to E1E2E3

    E4 to FF

    RemarkFixed data-1Fixed data-2Fixed data-1Fixed data-2

    Fixed data-1Fixed data-2Fixed data-1Fixed data-2Fixed data-1Fixed data-2(Modified data. Copy the databuilt in the same model.)

    Fixed data-1Fixed data-2

    Fixed data-1Fixed data-2

    Fixed data-1

    Table. 6-1-18.

  • 6-19HDR-FX1/FX1E

    1-3. CAMERA SYSTEM ADJUSTMENTSBefore perform the camera system adjustments (except for OriginOscillation Check), check that the specified values of VIDEOSYSTEM ADJUSTMENTS are satisfied.And check that the data of page: 0, address: 10 is 00. If not, setdata: 00 to this address.

    1. Origin Oscillation Check (VC-367 board)Check the frequency of the clock for synchronization.If deviated, the synchronization will be disrupted and the color willbecome inconsistent.Note1: 80.9090MHz ...... HDR-FX1 (NTSC)

    81.0MHz ............ HDR-FX1E (PAL)Subject Not requiredMeasurement Point CD-522 board R149

    (Pin

  • 6-20HDR-FX1/FX1E

    2. HALL AdjustmentFor detecting the position of the lens iris and ND filter, adjust AMPgain and offset.Subject Not requiredMeasurement Point Display data of page 1 (Note1)Measuring Instrument Adjustment remote commanderAdjustment Page FAdjustment Address 13 to 17, 24 to 27Specified Value 1 86 to 8ASpecified Value 2 15 to 19Specified Value 3 29 to 33Specified Value 4 6D to 77

    Note1: Displayed data of page 1 of the adjustment remote commander.1 : XX : XX

    IRIS display dataND display data

    Note2: The data of page: 0, address: 10 must be 00.Note3: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 6 94 88 Set the data.3 6 95 17 Set the data.4 6 96 72 Set the data.5 6 97 2E Set the data.6 6 01 6D Set the data, and press PAUSE

    button.7 6 02 Check that the data changes to

    01. (Note4)8 6 01 00 Set the data, and press PAUSE

    button.

    Note4: The adjustment data will be automatically input to page: F, address:13 to 17, 24 to 27.

    Checking method:Order Page Address Data Procedure1 0 03 03 Set the data.2 6 01 00 Set the data, and press PAUSE

    button.3 6 01 01 Set the data, and press PAUSE

    button.4 1 Check that the IRIS display data

    (Note1) satisfies the specifiedvalue 1.

    5 6 01 03 Set the data, and press PAUSEbutton.

    6 1 Check that the IRIS display data(Note1) satisfies the specifiedvalue.2.

    7 6 01 69 Set the data, and press PAUSEbutton.

    8 1 Check that the ND display data(Note1) satisfies the specifiedvalue 3.

    9 6 01 6B Set the data, and press PAUSEbutton.

    10 1 Check that the ND display data(Note1) satisfies the specifiedvalue.4.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 94 00 Set the data.2 6 95 00 Set the data.3 6 96 00 Set the data.4 6 97 00 Set the data.5 6 01 00 Set the data, and press PAUSE

    button.6 0 03 00 Set the data.7 0 01 00 Set the data.

  • 6-21HDR-FX1/FX1E

    3. MR AdjustmentThe MR (Magnet resistor) adjustment of the inner focus lens iscarried out automatically. In whichever case, the focus will bedeviated during auto focusing/manual focusing.Subject Not requiredMeasurement Point Adjustment remote commanderMeasuring InstrumentAdjustment Page FAdjustment Address 70 to 7CSpecified Value1 40 to C0Specified Value2 03 to 78Specified Value3 88 to F8

    Note1: Make the lens horizontal and perform this adjustment.Note2: Perform this adjustment before Flange Back Adjustment.Note3: The data of page: 0, address: 10 must be 00.Note4: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 F 70 Set bit2 and bit3 of the data to

    0, and press PAUSE button.(Note6)

    3 6 01 BD Set the data, and press PAUSEbutton.

    4 6 02 Check that the data changes to01. (Note5)

    5 F 71 Check that the data satisfies thespecified value 1.

    6 F 72 Check that the data satisfies thespecified value 1.

    7 F 73 Check that the data satisfies thespecified value 1.

    8 F 74 Check that the data satisfies thespecified value 1.

    9 F 75 Check that the data satisfies thespecified value 2.

    10 F 76 Check that the data satisfies thespecified value 3.

    11 F 77 Check that the data satisfies thespecified value 2.

    12 F 78 Check that the data satisfies thespecified value 3.

    13 F 79 Check that the data satisfies thespecified value 2.

    14 F 7A Check that the data satisfies thespecified value 3.

    15 F 7B Check that the data satisfies thespecified value 2.

    16 F 7C Check that the data satisfies thespecified value 3.

    Note5: The adjustment data will be automatically input to page: F, address:70 to 7C.

    Note6: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bitvalue discrimination.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.3 Turn off the power and turn on

    again

  • 6-22HDR-FX1/FX1E

    4. Focus Ring AdjustmentThe MR (Magnet resistor) adjustment of the focus ring is carriedout semi-automatically.Subject Not requiredMeasurement Point Adjustment remote commanderMeasuring InstrumentAdjustment Page FAdjustment Address 70, A6, A7, EC to EFSpecified Value1 40 to C0Specified Value2 03 to 78Specified Value3 88 to F8

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 F 70 Set bit6 of the data to 0, and

    press PAUSE button. (Note4)3 While rotating the focus ring, do

    from Step 3 to Step 4.4 6 01 B1 Set the data, and press PAUSE

    button.5 6 02 Check that the data changes to

    01 within 10 sec. (Note3)6 F A6 Check that the data satisfies the

    specified value 1.7 F A7 Check that the data satisfies the

    specified value 1.8 F EC Check that the data satisfies the

    specified value 2.9 F ED Check that the data satisfies the

    specified value 3.10 F EE Check that the data satisfies the

    specified value 2.11 F EF Check that the data satisfies the

    specified value 3.

    Note3: The adjustment data will be automatically input to page: F, address:70, A6, A7, EC to EF.

    Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bitvalue discrimination.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.

    5. Zoom Ring Adjustment (1)The MR (Magnet resistor) adjustment of the zoom ring is carriedout semi-automatically.Subject Not requiredMeasurement Point Adjustment remote commanderMeasuring InstrumentAdjustment Page FAdjustment Address 70, A8, A9, F0 to F3Specified Value1 40 to C0Specified Value2 03 to 78Specified Value3 88 to F8

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 F 70 Set bit7 of the data to 0, and

    press PAUSE button. (Note5)3 While shuttling the zoom ring

    between TELE end and WIDEend, do from Step 3 to Step 4.(Note3)

    4 6 01 B3 Set the data, and press PAUSEbutton.

    5 6 02 Check that the data changes to01 within 10 sec. (Note4)

    6 F A8 Check that the data satisfies thespecified value 1.

    7 F A9 Check that the data satisfies thespecified value 1.

    8 F F0 Check that the data satisfies thespecified value 2.

    9 F F1 Check that the data satisfies thespecified value 3.

    10 F F2 Check that the data satisfies thespecified value 2.

    11 F F3 Check that the data satisfies thespecified value 3.

    Note3: The rotating time between TELE end and WIDE end must be 1sec. or more.

    Note4: The adjustment data will be automatically input to page: F, address:70, A8, A9, F0 to F3.

    Note5: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bitvalue discrimination.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.

  • 6-23HDR-FX1/FX1E

    6. Zoom Ring Adjustment (2)The end sensor adjustment of the zoom ring is carried out semi-automatically.Subject Not requiredMeasurement Point Display data of page 1 (Note3)Measuring Instrument Adjustment remote commanderAdjustment Page FAdjustment Address E8 to EBSpecified Value Bit1 = 1, Bit2 = 1, Bit6 = 0 (Note3)

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.Note3: Displayed data of page 1 of the adjustment remote commander.

    1 : Y Z : XXObject data 2Object data 1

    When the specified value is satisfied. the object data 1 (Y) is 0to 3 or 8 to B, and the object data 2 (Z) is 6, 7, E orF.

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 6 01 B5 Set the data, and press PAUSE

    button.3 Rotate the zoom ring to WIDE

    end slowly.4 Rotate the zoom ring to TELE

    end slowly.5 6 01 B7 Set the data, and press PAUSE

    button.6 6 02 Check that the data changes to

    01. (Note3)7 0 03 28 Set the data.8 1 Check that bit1, bit2 and bit6 of

    the data satisfy the specifiedvalue.

    Note3: The adjustment data will be automatically input to page: F, address:E8 to EB.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.

  • 6-24HDR-FX1/FX1E

    7. Flange Back Adjustment(Using Minipattern Box or Flange Back Adjustment Jig)The inner focus lens flange back adjustment is carried outautomatically. In whichever case, the focus will be deviated duringauto focusing/manual focusing.Subject Flange back adjustment jig

    Or minipattern box (Siemens starchart with ND filter (Note1))

    Measurement Point Adjustment remote commanderMeasuring InstrumentAdjustment Page FAdjustment Address 60 to 70, F4Specified Value Data of page: F, address: 6F is 00 to

    0E.

    Note1: Dark Siemens star chart.Note2: This adjustment should be carried out upon completion of the

    following adjustments.HALL Adjustment, MR Adjustment

    Note3: Make the lens horizontal and perform this adjustment.Note4: The data of page: 0, address: 10 must be 00.Note5: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:ND FILTER .............................................................................OFF (Page: 6, Address: 9B, Bit4=0, Bit5=0)

    Preparations for the minipattern box:1) Remove the lens food.2) The minipattern box is installed as shown in the following

    figure.Note: The attachment lenses are not used.

    3) Install the minipattern box so that the distance between it andthe front of the lens of the camcorder is less than 3cm.

    4) Make the height of the minipattern box and the camcorder equal.5) Check that the output voltage of the regulated power supply is

    the specified voltage.6) Check that at both the zoom TELE end and WIDE end, the

    center of the Siemens star chart and center of the monitor TVscreen coincide.

    Specified voltage:The specified voltage varies according to the minipattern box, soadjust the power supply output voltage to the specified voltagewritten on the sheet which is supplied with the minipattern box.

    Preparations for the flange back adjustment jig:1) Remove the lens food.2) Install the flange back adjustment jig so that the distance

    between it and the front of the lens of the camcorder is lessthan 3cm.

    3) Make the height of the flange back adjustment jig and thecamcorder equal.

    4) Adjust the illumination intensity to the chart of the flange backadjustment jig. (350 50 lux)

    5) Check that at both the zoom TELE end and WIDE end, thecenter of the chart and center of the monitor TV screen coincide.

    Fig. 6-1-8.

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 6 01 13 Set the data, and press PAUSE

    button.3 6 01 27 Set the data, and press PAUSE

    button.4 6 02 Check that the data changes to

    01. (Note6)5 F 6F Check that the data is 00 to

    0E.

    Note6: The adjustment data will be automatically input to page: F, address:60 to 70, F4.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.3 Perform Flange Back Check.

    Minipattern box

    Below 3 cm

    Camcorder

    Camera table

    Red (+)Black ()

    Yellow (SENS +)White (SENS )

    Black (GND)Need not connected

    Regulated power supplyOutput voltage : Specified voltage 0.01Vdc

    Output current : more than 3.5A

    Fig. 6-1-7.

    Flange back adjustment jig Below 3 cm

    Camcorder

  • 6-25HDR-FX1/FX1E

    8. Flange Back Adjustment (Using Flange BackAdjustment Chart and Subject More Than 500m Away)

    The inner focus lens flange back adjustment is carried outautomatically. In whichever case, the focus will be deviated duringauto focusing/manual focusing.

    8-1. Flange Back Adjustment (1)Subject Flange back adjustment chart

    (2.0 m from the lens)(Luminance: 350 50 lux)

    Measurement Point Adjustment remote commanderMeasuring InstrumentAdjustment Page FAdjustment Address 60 to 70, F4Specified Value Data of page: F, address: 6F is 00 to

    0E.

    Note1: This adjustment should be carried out upon completion of thefollowing adjustments.

    HALL Adjustment, MR AdjustmentNote2: Make the lens horizontal and perform this adjustment.Note3: The data of page: 0, address: 10 must be 00.Note4: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:ND FILTER .............................................................................OFF (Page: 6, Address: 9B, Bit4=0, Bit5=0)

    Preparations:1) Check that at both the zoom TELE end and WIDE end, the

    center of the chart and center of the monitor TV screen coincide.

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 6 01 13 Set the data, and press PAUSE

    button.3 6 01 15 Set the data, and press PAUSE

    button.4 6 02 Check that the data changes to

    01. (Note5)5 F 6F Check that the data is 00 to

    0E.

    Note5: The adjustment data will be automatically input to page: F, address:60 to 70, F4.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 Perform Flange Back

    Adjustment (2)

    8-2. Flange Back Adjustment (2)Perform this adjustment after performing Flange Back Adjustment (1).Subject Subject more than 500m away

    (Subjects with clear contrast such asbuildings, etc.)

    Measurement Point Check operation on TV monitorMeasuring InstrumentAdjustment Page FAdjustment Address 60 to 70, F4

    Note1: Make the lens horizontal and perform this adjustment.Note2: The data of page: 0, address: 10 must be 00.Note3: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:ND FILTER .............................................................................OFF (Page: 6, Address: 9B, Bit4=0, Bit5=0)

    Preparations:1) Set the zoom to the TELE end and expose a subject that is

    more than 500m away (subject with clear contrast such asbuilding, etc.). (Nearby subjects less than 500m away shouldnot be in the screen.)

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 6 01 13 Set the data, and press PAUSE

    button.3 Place a ND filter on the lens so

    that the optimum image isobtain.

    4 6 01 29 Set the data, and press PAUSEbutton.

    5 6 02 Check that the data changes to01. (Note4)

    Note4: The adjustment data will be automatically input to page: F, address:60 to 70, F4.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 Perform Flange Back Check

  • 6-26HDR-FX1/FX1E

    9. Flange Back CheckSubject Siemens star

    (2.0m from the front of the lens)(Luminance: 300 50 lux)

    Measurement Point Check operation on TV monitorMeasuring InstrumentSpecified Value Focused at the TELE end and WIDE

    end.

    Note: The data of page: 0, address: 10 must be 00.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER......................................................................OFF

    (Page: 6, Address: 9B, Bit4=0, Bit5=0)

    Checking method:1) Place the Siemens star 2.0m from the front of the lens.2) To open the IRIS, decrease the luminous intensity to the

    Siemens star up to a point before noise appear on the image.3) Shoot the Siemens star with the zoom TELE end.4) Set the FOCUS switch to AUTO.5) Check that the lens is focused.6) Set the FOCUS switch to MANUAL.9) Change the zoom to the WIDE side from the TELE side, and

    observe the TV monitor and check that the lens is focused.

  • 6-27HDR-FX1/FX1E

    10. Picture Frame SettingWhen performing the following adjustments (except for MAXGAIN Adjustment), set the picture frame to HD color bar standardpicture frame.Subject Color bar chart

    (HD color bar standard picture frame)(0.4m (PTB-1450) or 1.0m (PTB-450)from the front of the lens)

    Measurement Point COMPONENT connectorMeasuring Instrument Oscilloscope and HD TV monitorSpecified Value A=B, C=D, E=0, F=0

    Note1: The data of page: 0, address: 10 must be 00Note2: When the component video signals are not output, connect the

    SW terminal (Pinq;) of the COMPONENT connector to GND.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER......................................................................OFF

    (Page: 6, Address: 9B, Bit4=0, Bit5=0)3) FOCUS .................................................................. MANUAL4) ZOOM RING/LEVER ............................................... LEVER

    Setting method:Order Page Address Data Procedure1 6 2C 11 Set the data.2 6 90 Set the following data.

    00 (PTB-1450), F4 (PTB-450)3 6 91 Set the following data.

    03 (PTB-1450), 02 (PTB-450)4 6 92 Set the following data.

    80 (PTB-1450), 5C (PTB-450)5 6 93 Set the following data.

    62 (PTB-1450), 43 (PTB-450)6 6 01 79 Set the data, and press PAUSE

    button.7 Adjust the camera direction, and

    set to the specified position.8 Perform the following

    adjustments. (Note3)

    Note3: When using the clear chart, remove the color bar chart from thepattern box and insert a clear chart in its place. (Do not performzoom operations during this time.)

    How to release the picture frame setting:Order Page Address Data Procedure1 0 10 00 Set the data.2 6 2C 00 Set the data.3 6 01 00 Set the data, and press PAUSE

    button.4 6 90 00 Set the data.5 6 91 00 Set the data.6 6 92 00 Set the data.7 6 93 00 Set the data.

    Check on the oscilloscope

    1. Horizontal period

    Fig. 6-1-9.

    2. Vertical period

    Fig. 6-1-10.

    Check on the monitor TV (Underscanned mode)

    Fig. 6-1-11.

    A=B C=D

    AB C

    D

    H

    E = 0 (msec), F = 0 (msec)E F

    V

    A=BC=D

    E = 0 (mm)F = 0 (mm)

    AB C

    D

    E

    F

    Color bar chart picture frame Monitor TV picture frame

  • 6-28HDR-FX1/FX1E

    11. Auto White Balance Standard Data InputND OFF

    Adjust the white balance reference at 3200K when the ND filterswitch is OFF.Subject Clear chart

    (HD color bar standard picture frame)Adjustment Page FAdjustment Address 2A to 2D

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER......................................................................OFF

    (Page: 6, Address: 9B, Bit4=0, Bit5=0)3) FOCUS .................................................................. MANUAL4) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 6 01 11 Set the data, and press PAUSE

    button.3 6 01 0B Set the data, and press PAUSE

    button.4 6 02 Check that the data changes to

    01. (Note3)

    Note3: The adjustment data will be automatically input to page: F, address:2A to 2D.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.

    12. Auto White Balance Standard Data InputND 1

    Adjust the white balance reference at 3200K when the ND filterswitch is 1.Subject Clear chart

    (HD color bar standard picture frame)Adjustment Page FAdjustment Address CC to CF

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER........................................................................... 1

    (Page: 6, Address: 9B, Bit4=1, Bit5=0)3) FOCUS .................................................................. MANUAL4) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 Set ND FILTRE switch to 1.2 0 01 01 Set the data.3 6 01 11 Set the data, and press PAUSE

    button.4 6 01 0B Set the data, and press PAUSE

    button.5 6 02 Check that the data changes to

    01. (Note3)

    Note3: The adjustment data will be automatically input to page: F, address:CC to CF.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.3 Set ND FILTRE switch to

    OFF.

  • 6-29HDR-FX1/FX1E

    13. Auto White Balance Standard Data InputND 2

    Adjust the white balance reference at 3200K when the ND filterswitch is 2.Subject Clear chart

    (HD color bar standard picture frame)Adjustment Page FAdjustment Address D4 to D7

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER........................................................................... 2

    (Page: 6, Address: 9B, Bit4=0, Bit5=1)3) FOCUS .................................................................. MANUAL4) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 Set ND FILTRE switch to 2.2 0 01 01 Set the data.3 6 01 11 Set the data, and press PAUSE

    button.4 6 01 0B Set the data, and press PAUSE

    button.5 6 02 Check that the data changes to

    01. (Note3)

    Note3: The adjustment data will be automatically input to page: F, address:D4 to D7.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.3 Set ND FILTRE switch to

    OFF.

    14. MAX GAIN AdjustmentSetting the minimum illumination.If it is not consistent, the image level required for taking subjects inlow illuminance will not be produced (dark).Subject Clear chart

    (HD color bar standard picture frame)Adjustment Page FAdjustment Address 19

    Note1: This adjustment should be carried out upon completion of AutoWhite Balance Standard Data Input.

    Note2: The data of page: 0, address: 10 must be 00.Note3: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.Note4: NTSC model: HDR-FX1

    PAL model: HDR-FX1E

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER......................................................................OFF

    (Page: 6, Address: 9B, Bit4=0, Bit5=0)3) STEADY SHOT (CAMERA SET menu) ........................OFF4) FOCUS .................................................................. MANUAL5) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 0 01 01 Set the data.2 6 30 01 Set the data.3 6 C9 10 Set the data.4 6 96 Set the following data. (PTB-1450)

    35 (NTSC), 2A (PAL)Set the following data. (PTB-450)31 (NTSC), 26 (PAL)

    5 6 97 00 Set the data.6 6 01 6F Set the data, and press PAUSE

    button.7 6 02 Check that the data changes to

    01. (Note5)

    Note5: The adjustment data will be automatically input to page: F, address:19.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 30 00 Set the data.2 6 C9 00 Set the data.3 6 96 00 Set the data.4 6 97 00 Set the data.5 6 01 00 Set the data, and press PAUSE

    button.6 0 01 00 Set the data.

  • 6-30HDR-FX1/FX1E

    15. LV Standard Data InputAdjust the normal coefficient of the light value.Subject Clear chart

    (HD color bar standard picture frame)Measurement Point Display data of page 1 (Note4)Measuring Instrument Adjustment remote commanderAdjustment Page FAdjustment Address 1A, 1BSpecified Value 0FE0 to 1020

    Note1: This adjustment should be carried out upon completion of AutoWhite Balance Standard Data Input.

    Note2: The data of page: 0, address: 10 must be 00.Note3: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.Note4: Displayed data of page 1 of the adjustment remote commander.

    1 : XX : XXDisplay data

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER......................................................................OFF

    (Page: 6, Address: 9B, Bit4=0, Bit5=0)3) STEADY SHOT (CAMERA SET menu) ........................OFF4) FOCUS .................................................................. MANUAL5) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 Check the picture frame.

    Refer to 10. Picture FrameSetting.)

    2 0 01 01 Set the data.3 6 30 01 Set the data.4 6 C9 10 Set the data.5 6 01 0D Set the data, and press PAUSE

    button.6 6 02 Check that the data changes to

    01. (Note5)7 0 03 1E Set the data.8 1 Check that the display data

    (Note4) satisfies the specifiedvalue. (Note6)

    Note5: The adjustment data will be automatically input to page: F, address:1A, 1B.

    Note6: If it isnt satisfied, repeat the adjustment again.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 6 30 00 Set the data.3 6 C9 00 Set the data.4 0 03 00 Set the data.5 0 01 00 Set the data.

    16. Auto White Balance Adjustment ND OFFAdjust to the proper auto white balance output data when the NDfilter switch is OFF.If it is not correct, auto white balance and color reproducibility willbe poor.Subject Clear chart

    (HD color bar standard picture frame)Filter Filter C14 for color temperature

    correctionAdjustment Page FAdjustment Address 3C to 3F, 40 to 43

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER......................................................................OFF

    (Page: 6, Address: 9B, Bit4=0, Bit5=0)3) FOCUS .................................................................. MANUAL4) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 Place the C14 filter for color

    temperature correction on thelens.

    2 0 01 01 Set the data.3 F 3C 2B Set the data, and press PAUSE

    button.4 F 3D E0 Set the data, and press PAUSE

    button.5 F 3E 58 Set the data, and press PAUSE

    button.6 F 3F 78 Set the data, and press PAUSE

    button.7 6 01 83 Set the data, and press PAUSE

    button.8 6 01 81 Set the data, and press PAUSE

    button.9 6 02 Check that the data changes to

    01. (Note3)

    Note3: The adjustment data will be automatically input to page: F, address:40 to 43.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.3 Remove the C14 filter.

  • 6-31HDR-FX1/FX1E

    17. Auto White Balance Adjustment ND 1Adjust to the proper auto white balance output data when the NDfilter switch is 1.If it is not correct, auto white balance and color reproducibility willbe poor.Subject Clear chart

    (HD color bar standard picture frame)Filter Filter C14 for color temperature

    correctionAdjustment Page FAdjustment Address 3C to 3F, D0 to D3

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER........................................................................... 1

    (Page: 6, Address: 9B, Bit4=1, Bit5=0)3) FOCUS .................................................................. MANUAL4) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 Place the C14 filter for color

    temperature correction on thelens.

    2 Set ND FILTRE switch to 1.3 0 01 01 Set the data.4 F 3C 2B Set the data, and press PAUSE

    button.5 F 3D E0 Set the data, and press PAUSE

    button.6 F 3E 58 Set the data, and press PAUSE

    button.7 F 3F 78 Set the data, and press PAUSE

    button.8 6 01 83 Set the data, and press PAUSE

    button.9 6 01 81 Set the data, and press PAUSE

    button.10 6 02 Check that the data changes to

    01. (Note3)

    Note3: The adjustment data will be automatically input to page: F, address:D0 to D3.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.3 Remove the C14 filter.4 Set ND FILTRE switch to

    OFF.

    18. Auto White Balance Adjustment ND 2Adjust to the proper auto white balance output data when the NDfilter switch is 2.If it is not correct, auto white balance and color reproducibility willbe poor.Subject Clear chart

    (HD color bar standard picture frame)Filter Filter C14 for color temperature

    correctionAdjustment Page FAdjustment Address 3C to 3F, D8 to DB

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER........................................................................... 2

    (Page: 6, Address: 9B, Bit4=0, Bit5=1)3) FOCUS .................................................................. MANUAL4) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 Place the C14 filter for color

    temperature correction on thelens.

    2 Set ND FILTRE switch to 2.3 0 01 01 Set the data.4 F 3C 2B Set the data, and press PAUSE

    button.5 F 3D E0 Set the data, and press PAUSE

    button.6 F 3E 58 Set the data, and press PAUSE

    button.7 F 3F 78 Set the data, and press PAUSE

    button.8 6 01 83 Set the data, and press PAUSE

    button.9 6 01 81 Set the data, and press PAUSE

    button.10 6 02 Check that the data changes to

    01. (Note3)

    Note3: The adjustment data will be automatically input to page: F, address:D8 to DB.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 0 01 00 Set the data.3 Remove the C14 filter.4 Set ND FILTRE switch to

    OFF.

  • 6-32HDR-FX1/FX1E

    19. Color Reproduction Adjustment ND OFFAdjust the hue and gain of R-Y and B-Y signals so that propercolor reproduction is produced when the ND filter switch is OFF.Subject Color bar chart

    (HD color bar standard picture frame)Measurement Point COMPONENT connectorMeasuring Instrument OscilloscopeAdjustment Page FAdjustment Address 38 to 3B (HD)

    B4 to B7 (SD)C0 to C3 (HD CINE)DC to DF (SD CINE)

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER......................................................................OFF

    (Page: 6, Address: 9B, Bit4=0, Bit5=0)3) FOCUS .................................................................. MANUAL4) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 Set the color bar chart, and

    check the picture frame.(Refer to 10. Picture FrameSetting.)

    2 0 01 01 Set the data.3 6 01 4D Set the data, and press PAUSE

    button.4 6 9D Change the data and set the Y

    signal level (A) to 630mV.(Note3) (Fig. 6-1-12.)

    5 6 9E 22 Set the data.6 6 12 80 Set the data.7 6 12 00 Set the data.8 Check that the Y signal level (A)

    is 630mV.9 6 01 61 Set the data, and press PAUSE

    button.10 6 02 Check that the data changes to

    01. (Note4)

    Note3: The Y signal terminal (Pin 1) of the COMPONENT connectormust be terminated at 75 .(When the component video signals are not outputted, connectthe SW terminal (Pin q;) of the COMPONENT connector toGND.)

    Note4: The adjustment data will be automatically input to page: F, address:38 to 3B, B4 to B7, C0 to C3, DC to DF.

    Fig. 6-1-12.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 6 9D 00 Set the data.3 0 01 00 Set the data.

    A

    H

  • 6-33HDR-FX1/FX1E

    20. Color Reproduction Adjustment ND 1Adjust the hue and gain of R-Y and B-Y signals so that propercolor reproduction is produced when the ND filter switch is 1.Subject Color bar chart

    (HD color bar standard picture frame)Measurement Point COMPONENT connectorMeasuring Instrument OscilloscopeAdjustment Page FAdjustment Address AC to AF (HD)

    B8 to BB (SD)C4 to C7 (HD CINE)E0 to E3 (SD CINE)

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER........................................................................... 1

    (Page: 6, Address: 9B, Bit4=1, Bit5=0)3) FOCUS .................................................................. MANUAL4) ZOOM ........................................................................ LEVER

    Adjusting method:Order Page Address Data Procedure1 Set ND FILTRE switch to 1.2 0 01 01 Set the data.3 6 01 4D Set the data, and press PAUSE

    button.4 6 9D Change the data and set the Y

    signal level (A) to 630mV.(Note3) (Fig. 6-1-12.)

    5 6 9E 22 Set the data.6 6 12 80 Set the data.7 6 12 00 Set the data.8 Check that the Y signal level (A)

    is 630mV.9 6 01 61 Set the data, and press PAUSE

    button.10 6 02 Check that the data changes to

    01. (Note4)

    Note3: The Y signal terminal (Pin 1) of the COMPONENT connectormust be terminated at 75 .

    Note4: The adjustment data will be automatically input to page: F, address:AC to AF, B8 to BB, C4 to C7, E0 to E3.

    Processing after Completing Adjustments:Order Page Address Data Procedure1 6 01 00 Set the data, and press PAUSE

    button.2 6 9D 00 Set the data.3 0 01 00 Set the data.4 Set ND FILTRE switch to

    OFF.

    21. Color Reproduction Adjustment ND 2Adjust the hue and gain of R-Y and B-Y signals so that propercolor reproduction is produced when the ND filter switch is 2.Subject Color bar chart

    (HD color bar standard picture frame)Measurement Point COMPONENT connectorMeasuring Instrument OscilloscopeAdjustment Page FAdjustment Address B0 to B3 (HD)

    BC to BF (SD)C8 to CB (HD CINE)E4 to E7 (SD CINE)

    Note1: The data of page: 0, address: 10 must be 00.Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:

    6, address: 01, set data: 00, and press the PAUSE button.

    Switch setting:1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i

    (Page: 6, Address: 9B, Bit2=0)2) ND FILTER........................................................................... 2

    (Page: 6, Address: 9B, Bit4=0, Bit5=1)3) FOCUS ............................................................