soundsens i tech sheet - water management and leak detection
TRANSCRIPT
SoundSens “i”Correlating Noise Loggers Halma Water Management
■ USB communications with PC.
■ Infra Red communications with
loggers (no connections required).
■ Simultaneous communications
with all loggers for fast recording
setup.
■ LCD screen with backlight.
■ Push button interface.
■ Battery LED indicates when
battery is running low. Case-
typically 2 months between
charges. Pods have 5 year typical
battery life.
■ Cases can be linked for simulta-
neous set up and download.
Introduction
Soundsens “i” is the latest
version of the popular
Soundsens correlating loggers.
The system, along with the
latest software is designed for
performance, versatility and
speed of operations in the
field, allowing for set up and
download without a PC if
preferred. The unit has the
potential to store up to a
weeks survey data for before
the need for downloading to a
PC, making work patterns
more flexible.
Loggers are downloaded via
infra red and as there is no
requirement for physical connection, deployment and
download is much faster.
Boxes of loggers can be connected together to allow
simultaneous programming and downloading of data from
all loggers. This, combined with communication to a PC via
USB means that leak detection work is done quickly and
efficiently. Now available in purpose designed mini-kits (2,3
and 4 pod options).
Features
■ User can setup loggers and download data without using PC.
■ Quick recording setup for day or night Recordings.
■ Custom recording setup available.
■ Multiple downloads of data can be stored.
■ Simultaneous download of data from all loggers.
For more information call +44 (0) 1633 489479or visit www.hwm-water.com
A Halma Group Company g Company is ISO 9001 Registered No.06134A
F L OW M E A S U R E M E N T DATA L O G G I N G L E A K D E T E C T I O N P R E S S U R E M A NAG E M E N T
INFRA REDPORTABLE
5 YEAR
BATTERY
LIFE
CASE
SET-UP
SoundSens “i”Correlating Noise Loggers
P R O D U C T S P E C I F I C A T I O N
Halma Water Management
F L OW M E A S U R E M E N T DATA L O G G I N G L E A K D E T E C T I O N P R E S S U R E M A NAG E M E N T
gHalma Water Management a Division of Palmer Environmental
Ty Coch House Llantarnam Park Way Cwmbran Gwent NP44 3AW United Kingdom
g Tel: +44 (0) 1633 489479 Fax: +44 (0) 1633 877857 g [email protected] www.hwm-water.com
g Registered Address: Ty Coch House Llantarnam Park Way Cwmbran Gwent NP44 3AW
g Registered in England No: 1463016
HW
MSo
unds
ens6
/200
7
Sensor Input Internal High Performance Accelerometer to pickup audible noise in pipeline
Attachment Powerful magnetic coupling to attach Correlator Pod to
of logger/ sensor pipework / valve
Memory Recording 650,000 readings. (memory expandable to 1.35 million readings on request)
Individual measurements can be pre-programmed into a series of 32 separate recordings
Sample Rate User adjustable
Logging Delayed start Either start at a nominated time, or after set delay period, e.g; for unmanned
Features night-time correlation
Logger ID Factory set Logger ID number
Also user can enter another logger Identity number to simplify recognition for operators
Clock On board 24 hour real time clock with date facility.
Software Compatible with Radcom “SoundSens” analysis software
Case to PC Via USB connection to PC for faster download
Communications Case to Pods Simultaneous communication from case to pod viainfra red
Case to Case Via 9 pin RS232
Dimensions Individual Advanced Correlator Pod now with reduced dimensions:
160 H incl Magnet x 55Diam mm (6.3H x2.10D”)
Construction CPod: Die-cast aluminium enclosure, powdercoat spray painted
Carry Case: Rugged construction with Aluminium Cladding
Physical Weight Individual Correlator Pod: 0.7 kg (1.54 lb)
Carry Case Supplied in 2 - 4 pod case or 6 - 8 pod case
(Any number of cases can be connected together)
Operating temp -10 to +50°C (14 to +122°F)
Ingress protection Individual Correlator Pods: IP68 submersible
Power Correlator pod has Lithium-ion cell operational for 5 years under normal
operating conditions.
Carry Case interface unit contains NiCad battery which typically requires
charging monthly or less.
240 /110v switch mode charger supplied in kit with mains lead.
HWM reserve the right to change the specification of any product without prior notice.