Dear Sir
LOCATION: Lakeland Leisure Park, Moor Lane, FLOOKBURGH
GEOCODE: Easting: 336998 Northing: 473953
DEVELOPMENT: Installation of two new windows, one new door and a covered pergola.
REFERENCE NUMBER: SL/2017/0765 (Please use this whenever you contact us)
PLANNING OFFICER: Gemma Heron
We have received the above application that you may wish to comment upon.
The following link will take you directly to the application: http://kdc-pam.southlakeland.gov.uk/AniteIM.websearch/ExternalEntryPoint.aspx?SEARCH_TYPE=1&DOC_CLASS_CODE=DC&folder1_ref=SL/2017/0765
Or go to our website: http://applications.southlakeland.gov.uk/planningapplications/welcome.asp to view the documents.
Please send your comments by email: [email protected] before 21 days (3 October 2017).
If you do not reply within that period I will assume you have no comments.
Yours faithfully
Gemma HeronDevelopment Management
West P
lain
Farm
S
ig
n
Dra
in
R
H
7
16
11
8
3
12
17
2
4
13
14
5
TENNIS COURTS
SPORTSFIELD
FOOTPATH WALK
THROUGH WOOLAND
OPENSPACE
date
drawing no
project
client
title
scale
drawn by
the trading estatecommon lane kenilworth warwickshire CV8 2ELtelephone: +44 (0)1926 851454 fax: +44 (0)1926 851776
email: [email protected]
c this drawing and all the information hereon is copyright andremains the property of leisure concepts and any breach of thiscopyright will be prosecuted. wherever figured dimensions aregiven they are to be accepted in preference to scaled sizes. thecontractors are responsible for verifying all dimensions shownhereon before putting any affected work in hand.
Revisionsrev date description by
PRELIMINARY31 August 2017PRINT DATE:
GENERAL NOTES All Leisure Concepts drawings to be read in conjunction with
Architect, Structural Engineer, M&E Consultants and all otherspecialist contractors/ suppliers drawingsfor fit out area.
Drawing to be read in conjunction with all other LeisureConcepts drawings for area.
All works to be carried out by recommended installationcontractors to manufacturer's instructions/ recommendations
All work should comply with BS Codes of Practice and allStatutory Requirements
All dimensions are in millimetres unless stated otherwise. Set out to be discussed with Interior Designer prior to
commencement of works The Shop Fit trade contractor must familiarise himself with
the site and measure all areas affecting his work. Alldimensions to be verified on site prior to manufacture of anyartefact or works, on or off site.
Samples of all finishes showing realistic interpretation ofmaterial, texture, colour, reflectivity and quality of finishing tobe submitted to the Designer for approval, prior tomanufacture.
All softwood units and panelling to be in good quality,relatively knot-free softwood, clear and better, unsorted, withsheet materials faced in veneer to provide a good qualityfinish when varnished.
All edge trims and mouldings to be in solid wood (unlessotherwise specified) and finished to match.
Contractor to ensure that timber is Pre-treated as necessaryto comply with F.R requirements of Building Control and allfinishes to achieve good quality appearance as specified byarchitect.
Carcassing should be non-combustible or be certified asminimum Class 1 Surface Spread of Flame, in accordancewith BS476 Part 7 1971 or 1987.
Lighting and small power requirements shown are notnecessarily the total requirements. Service areas , toilets, airhandling, Building Regs requirements, specialist contractors'items e.g stage power is to be specified by "others."
The Contractor is to confirm total requirements with the M&EConsultant and specialist contractors.
All electrics to comply fully with 17th Edition and latestupdates & amendments as determined by NICEIC
HAVEN - LAKELAND
Mash & Barrel Refurbishment
Location Plan
1:5000 @ A3
JR
Aug 2017
2072b.1.01A
40m
0200m
A3
SC
ALE
1:5000
A 31.08.17 Scale changed to A3 JR
Elevation JScale 1:50
Elevation J (Cont.)Scale 1:50
Elevation KScale 1:50
date
drawing no
project
client
title
scale
drawn by
the trading estatecommon lane kenilworth warwickshire CV8 2ELtelephone: +44 (0)1926 851454 fax: +44 (0)1926 851776
email: [email protected]
c this drawing and all the information hereon is copyright andremains the property of leisure concepts and any breach of thiscopyright will be prosecuted. wherever figured dimensions aregiven they are to be accepted in preference to scaled sizes. thecontractors are responsible for verifying all dimensions shownhereon before putting any affected work in hand.
Revisions
21 August 2017PRINT DATE:
GENERAL NOTES All Leisure Concepts drawings to be read in
conjunction with Architect, Structural Engineer, M&EConsultants and all other specialist contractors/suppliers drawingsfor fit out area.
Drawing to be read in conjunction with all otherLeisure Concepts drawings for area.
All works to be carried out by recommendedinstallation contractors to manufacturer'sinstructions/ recommendations
All work should comply with BS Codes of Practiceand all Statutory Requirements
All dimensions are in millimetres unless statedotherwise.
Set out to be discussed with Interior Designer priorto commencement of works
The Shop Fit trade contractor must familiarisehimself with the site and measure all areas affectinghis work. All dimensions to be verified on site prior tomanufacture of any artefact or works, on or off site.
Samples of all finishes showing realisticinterpretation of material, texture, colour, reflectivityand quality of finishing to be submitted to theDesigner for approval, prior to manufacture.
All softwood units and panelling to be in goodquality, relatively knot-free softwood, clear andbetter, unsorted, with sheet materials faced inveneer to provide a good quality finish whenvarnished.
All edge trims and mouldings to be in solid wood(unless otherwise specified) and finished to match.
Contractor to ensure that timber is Pre-treated asnecessary to comply with F.R requirements ofBuilding Control and all finishes to achieve goodquality appearance as specified by architect.
Carcassing should be non-combustible or becertified as minimum Class 1 Surface Spread ofFlame, in accordance with BS476 Part 7 1971 or1987.
Lighting and small power requirements shown arenot necessarily the total requirements. Service areas, toilets, air handling, Building Regs requirements,specialist contractors' items e.g stage power is to bespecified by "others."
The Contractor is to confirm total requirements withthe M&E Consultant and specialist contractors.
All electrics to comply fully with 17th Edition andlatest updates & amendments as determined byNICEIC
HAVEN - LAKELAND
M&B Refurbishment
Existing External ElevationsSheet 1
1:50 @ A1
JR
Aug 2017
2072b.4.06
rev date description by
PLANNING
1m
05m
A1
SC
ALE
1:50
Site Location PlanScale 1:750
Owners Exclusive
Indoor Pool
SHOWBAR
GYM
Sauna
Steam
Spa
Gym
Plant Room
Climbing Frame
lpg
Female WC
Male WC
dis
smoking area
grass
plant
Adventure Golf
OUTDOOR POOL
Raised Decking
Childrens Play
Area
Decking
Acce
ss w
ay
tarmac
paved
high level
comms box
elec DB`s
repositioned
Servery
MASH AND BARREL
elec DB`s
repositioned
elec DB`s
repositioned
DELIVERY YARD
EXISTING ROAD RETAINED
KITCHEN
GLASS
WASH
3.24m²
RAMP - non dda
PLATFORM LIFT
Bar
Childrens Play
Area
Childrens Play
Area
Archery
Store
rwp
C. Ht: 2136
KitchenTakeaway
C
Pic 'n' Paint
C. Ht: 2979
C. Ht: 2041
C.
Ht: 2
58
3
C. Ht: 3000
C. Ht: 2650
C. Ht: 3685
C. Ht: 2757
C. Ht: 2289
C. Ht: 2570
C. Ht: 2970
C. Ht: 2650
C. Ht: 2650
C. H
t: 33
36
C. Ht: 2600
C. Ht: 2041
C. Ht: 3520
C. Ht: 2283
C. Ht: 3520 C. Ht: 2245
EXISTING BAR
LOUNGE
Bar
CELLAR
C. Ht: 2549
SPIRIT
276 Covers
56 Covers
122 Covers
1.10
2.10
2.09
2.07
1.02
2.08
2.14
6.06
6.07
New walls by
others
date
drawing no
project
client
title
scale
drawn by
the trading estatecommon lane kenilworth warwickshire CV8 2ELtelephone: +44 (0)1926 851454 fax: +44 (0)1926 851776
email: [email protected]
c this drawing and all the information hereon is copyright andremains the property of leisure concepts and any breach of thiscopyright will be prosecuted. wherever figured dimensions aregiven they are to be accepted in preference to scaled sizes. thecontractors are responsible for verifying all dimensions shownhereon before putting any affected work in hand.
Revisions
21 August 2017PRINT DATE:
GENERAL NOTES All Leisure Concepts drawings to be read in
conjunction with Architect, Structural Engineer, M&EConsultants and all other specialist contractors/suppliers drawingsfor fit out area.
Drawing to be read in conjunction with all otherLeisure Concepts drawings for area.
All works to be carried out by recommendedinstallation contractors to manufacturer'sinstructions/ recommendations
All work should comply with BS Codes of Practiceand all Statutory Requirements
All dimensions are in millimetres unless statedotherwise.
Set out to be discussed with Interior Designer priorto commencement of works
The Shop Fit trade contractor must familiarisehimself with the site and measure all areas affectinghis work. All dimensions to be verified on site prior tomanufacture of any artefact or works, on or off site.
Samples of all finishes showing realisticinterpretation of material, texture, colour, reflectivityand quality of finishing to be submitted to theDesigner for approval, prior to manufacture.
All softwood units and panelling to be in goodquality, relatively knot-free softwood, clear andbetter, unsorted, with sheet materials faced inveneer to provide a good quality finish whenvarnished.
All edge trims and mouldings to be in solid wood(unless otherwise specified) and finished to match.
Contractor to ensure that timber is Pre-treated asnecessary to comply with F.R requirements ofBuilding Control and all finishes to achieve goodquality appearance as specified by architect.
Carcassing should be non-combustible or becertified as minimum Class 1 Surface Spread ofFlame, in accordance with BS476 Part 7 1971 or1987.
Lighting and small power requirements shown arenot necessarily the total requirements. Service areas, toilets, air handling, Building Regs requirements,specialist contractors' items e.g stage power is to bespecified by "others."
The Contractor is to confirm total requirements withthe M&E Consultant and specialist contractors.
All electrics to comply fully with 17th Edition andlatest updates & amendments as determined byNICEIC
HAVEN - LAKELAND
M&B Refurbishment
Existing Layout Plan
1:200 @ A1
JR
Aug 2017
2072b.4.04
rev date description by
PLANNING
Site Location PlanScale 1:10000
10m
1m
0
A1
SC
ALE
1:200
Owners Exclusive
Indoor Pool
SHOWBAR
GYM
Sauna
Steam
Spa
Gym
Plant Room
Climbing Frame
lpg
Female WC
Male WC
dis
smoking area
grass
plant
Adventure Golf
OUTDOOR POOL
Raised Decking
Childrens Play
Area
Decking
Access w
ay
tarmac
paved
high level
comms box
elec DB`s
repositioned
Servery
MASH AND BARREL
elec DB`s
repositioned
elec DB`s
repositioned
Def
Drain
Drain
Def
Drain
Drain
DELIVERY YARD
EXISTING ROAD RETAINED
DRAIN
KITCHEN
GLASS
WASH
3.24m²
RAMP - non dda
PLATFORM LIFT
Bar
Sports and
leisure
bookings
Childrens Play
Area
Childrens Play
Area
AGCOffice
Office
Store
Store
Funworks
Archery
Store
Deck
rooflight
rooflight
rooflight rooflight
rooflight
rooflight
rooflight
r o o f l i g h t o v e r
r o o f l i g h t o v e r
rwp
rwp
rwp
rwp
rwp
rwp
rwp
rwp
rwp
rwp
rwp
ChangeKiosk
WinnersCircle
Bowling
Store
Elec. Distri.
C. Ht: 2278
Office
C. Ht: 2560
Cooks
C. Ht: 2955
C. Ht: 2154
Cellar
Kitchen
C. Ht: 2136
C. Ht: 2406
Pool Reception
Store
KitchenTakeaway
C. Ht: 2260
C.
Ht: 2
28
0
Arcade
C. Ht: 1996
Pic 'n' Paint
C. Ht: 2617
C. Ht: 2979
C. Ht: 2041
C. Ht: 2154
C.
Ht: 2
58
3
C. Ht: 2482
Decking
Gravel
Grass
C. Ht: 3000
C. Ht: 2650
C. Ht: 3685
C. Ht: 2757
C. Ht: 2289
C. Ht: 2570
C. Ht: 2970
C. Ht: 2650
C. Ht: 2650
C. H
t: 33
36
C. Ht: 2600
C. Ht: 2041
C. Ht: 3520
C. Ht: 2283
C. Ht: 3520 C. Ht: 2245
EXISTING BAR
LOUNGE
Bar
CELLAR
Planter
Planter
SUPER MARKET
CARAVAN SALES &
OFFICES
YARD
Deliveries
Decking
Reception
Offices
Laundrette
Offices
Foot Bridge
Grass
Grass
Tarmac Carpark
C. Ht: 2549
SPIRIT
YARD
Team Welfare
276 Covers
56 Covers
122 Covers
MULTI SPORTS PITCH
Office Parking
Planter
Dropped kerb
Dropped kerb
Dropped kerb
Dropped kerb
D
r
o
p
p
e
d
k
e
r
b
Dropped kerb
1.10
2.10
2.09
2.07
1.02
2.08
2.14
6.06
6.07
New walls by
others
C. Ht: 2055
C. H
t: 21
36
C. Ht: 2154
C. Ht: 1950
C. Ht: 2278 C. Ht: 2278
date
drawing no
project
client
title
scale
drawn by
the trading estatecommon lane kenilworth warwickshire CV8 2ELtelephone: +44 (0)1926 851454 fax: +44 (0)1926 851776
email: [email protected]
c this drawing and all the information hereon is copyright andremains the property of leisure concepts and any breach of thiscopyright will be prosecuted. wherever figured dimensions aregiven they are to be accepted in preference to scaled sizes. thecontractors are responsible for verifying all dimensions shownhereon before putting any affected work in hand.
Revisions
21 August 2017PRINT DATE:
GENERAL NOTES All Leisure Concepts drawings to be read in
conjunction with Architect, Structural Engineer, M&EConsultants and all other specialist contractors/suppliers drawingsfor fit out area.
Drawing to be read in conjunction with all otherLeisure Concepts drawings for area.
All works to be carried out by recommendedinstallation contractors to manufacturer'sinstructions/ recommendations
All work should comply with BS Codes of Practiceand all Statutory Requirements
All dimensions are in millimetres unless statedotherwise.
Set out to be discussed with Interior Designer priorto commencement of works
The Shop Fit trade contractor must familiarisehimself with the site and measure all areas affectinghis work. All dimensions to be verified on site prior tomanufacture of any artefact or works, on or off site.
Samples of all finishes showing realisticinterpretation of material, texture, colour, reflectivityand quality of finishing to be submitted to theDesigner for approval, prior to manufacture.
All softwood units and panelling to be in goodquality, relatively knot-free softwood, clear andbetter, unsorted, with sheet materials faced inveneer to provide a good quality finish whenvarnished.
All edge trims and mouldings to be in solid wood(unless otherwise specified) and finished to match.
Contractor to ensure that timber is Pre-treated asnecessary to comply with F.R requirements ofBuilding Control and all finishes to achieve goodquality appearance as specified by architect.
Carcassing should be non-combustible or becertified as minimum Class 1 Surface Spread ofFlame, in accordance with BS476 Part 7 1971 or1987.
Lighting and small power requirements shown arenot necessarily the total requirements. Service areas, toilets, air handling, Building Regs requirements,specialist contractors' items e.g stage power is to bespecified by "others."
The Contractor is to confirm total requirements withthe M&E Consultant and specialist contractors.
All electrics to comply fully with 17th Edition andlatest updates & amendments as determined byNICEIC
HAVEN - LAKELAND
M&B Refurbishment
Existing Site Plan
1:500 @ A1
JR
Aug 2017
2072b.4.02
rev date description by
PLANNING
Location PlanScale 1:10000
50m
10m
0
A1
SC
ALE
1:500
3982
3449
180
2674 1800 2674
1080
2924
300
Eq. Eq.
1800
1500
533
180 x 180mm timber postsforming pergola structure tbcstructural engineer
50 x 175 timber pergolajoist tbc by structuralengineer
Handrail to be 50mmmild steel tubepowdercoated finishTBC
10mm mild steelcross memberspowdercoated finishTBC
180 x 180 timberpost
Handrail to be 50mmmild steel tubepowdercoated finishTBC
Millboard facia to side ofraised floor. Spec. TBC
Dashed line indicating area of existing lower floorlevel (To be raised up to decking height)
50 x 175mm pergolarafters tbc by structuralengineer
Blockwork wall builtto shown height
finished in a whiterender with suitablefoundation spec bystructural engineer
Elevation A-AScale 1:20
230437
6650
2854 1980 2854
438 436
180 x 180mm timberposts forming pergolastructure
75mm RWP & gutterblack finish
50 x 175 timber pergolajoist tbc by structuralengineer
150 x 150 timber posts
Handrail to be 50mmmild steel tubepowdercoated finishTBC
75 x 225 mm pergolajoists tbc by structuralengineer
Blockwork wallbuilt to shown
height finishedin a white
render withsuitable
foundationspec by
structuralengineer
Blockwork wall builtto shown heightfinished in a whiterender with suitablefoundation spec bystructural engineer
5973
Pergola PlanScale 1:50
A
BB
A
1801176
1801176
1801176
1801176
180
180
903
180
180
1360
1801
360
1801
360
180
1700
135°
New location of ramp tobe constructed at 1:16
3149
300
175 357
66493195
180
172 180
900
3151
laid to fall by 50mm
180 x 180mm timberposts forming pergolastructure
50 x 175 timber pergolajoist tbc by structuralengineer
180 x 180 timberpost
Handrail to be 50mmmild steel tubepowdercoated finishTBC
New millboard decking laid onto existing subflooring. Contractor to allow for repairing anydamaged areas
New millboardsteps spec. TBC
Existing lower timberdecking to beretained, cleand andnew finishing stainapplied
75 x 225 mm pergolajoists tbc by structural
engineer
Existing windows
Post base plate &concrete foundation date
drawing no
project
client
title
scale
drawn by
the trading estatecommon lane kenilworth warwickshire CV8 2ELtelephone: +44 (0)1926 851454 fax: +44 (0)1926 851776
email: [email protected]
c this drawing and all the information hereon is copyright andremains the property of leisure concepts and any breach of thiscopyright will be prosecuted. wherever figured dimensions aregiven they are to be accepted in preference to scaled sizes. thecontractors are responsible for verifying all dimensions shownhereon before putting any affected work in hand.
Revisions
21 August 2017PRINT DATE:
GENERAL NOTES All Leisure Concepts drawings to be read in
conjunction with Architect, Structural Engineer, M&EConsultants and all other specialist contractors/suppliers drawingsfor fit out area.
Drawing to be read in conjunction with all otherLeisure Concepts drawings for area.
All works to be carried out by recommendedinstallation contractors to manufacturer'sinstructions/ recommendations
All work should comply with BS Codes of Practiceand all Statutory Requirements
All dimensions are in millimetres unless statedotherwise.
Set out to be discussed with Interior Designer priorto commencement of works
The Shop Fit trade contractor must familiarisehimself with the site and measure all areas affectinghis work. All dimensions to be verified on site prior tomanufacture of any artefact or works, on or off site.
Samples of all finishes showing realisticinterpretation of material, texture, colour, reflectivityand quality of finishing to be submitted to theDesigner for approval, prior to manufacture.
All softwood units and panelling to be in goodquality, relatively knot-free softwood, clear andbetter, unsorted, with sheet materials faced inveneer to provide a good quality finish whenvarnished.
All edge trims and mouldings to be in solid wood(unless otherwise specified) and finished to match.
Contractor to ensure that timber is Pre-treated asnecessary to comply with F.R requirements ofBuilding Control and all finishes to achieve goodquality appearance as specified by architect.
Carcassing should be non-combustible or becertified as minimum Class 1 Surface Spread ofFlame, in accordance with BS476 Part 7 1971 or1987.
Lighting and small power requirements shown arenot necessarily the total requirements. Service areas, toilets, air handling, Building Regs requirements,specialist contractors' items e.g stage power is to bespecified by "others."
The Contractor is to confirm total requirements withthe M&E Consultant and specialist contractors.
All electrics to comply fully with 17th Edition andlatest updates & amendments as determined byNICEIC
HAVEN - LAKELAND
M&B Refurbishment
Pergola Detail
As Shown @ A1
JR
Aug 2017
2072b.4.08
rev date description by
PLANNING
1m
05m
A1
SC
ALE
1:50
2m
1m
0
A1
SC
ALE
1:20
Elevation JScale 1:50
New block work,detail to be providedby structural engineer
Rendered wall to bepainted as per drg2072b.3.105
Existing plasticcorrugated roof to be
cut back
Existing floor level to be builtup to decking height inlocation of existing yard
New WindowServery
New Door
New balustrade pergola,see drg 2072b.3.108
Relocate ramp to newshown location
Retain and clean existingPVC cladding
Paint column, see drg2072b.3.105 for spec.
Paint walls, see drg2072b.3.105 for spec.
Retain existing balustradeto edge of pool
Elevation J (Cont.)Scale 1:50
Retain and clean existingPVC cladding
Paint walls, see drg2072b.3.105 for spec.
Elevation KScale 1:50
W02
Paint walls, see drg2072b.3.105 for spec.
Paint walls, see drg2072b.3.105 for spec.
Paint walls, see drg2072b.3.105 for spec.
New raised timberplanter
New window, seed drg2072b.3.30 for spec.
date
drawing no
project
client
title
scale
drawn by
the trading estatecommon lane kenilworth warwickshire CV8 2ELtelephone: +44 (0)1926 851454 fax: +44 (0)1926 851776
email: [email protected]
c this drawing and all the information hereon is copyright andremains the property of leisure concepts and any breach of thiscopyright will be prosecuted. wherever figured dimensions aregiven they are to be accepted in preference to scaled sizes. thecontractors are responsible for verifying all dimensions shownhereon before putting any affected work in hand.
Revisions
21 August 2017PRINT DATE:
GENERAL NOTES All Leisure Concepts drawings to be read in
conjunction with Architect, Structural Engineer, M&EConsultants and all other specialist contractors/suppliers drawingsfor fit out area.
Drawing to be read in conjunction with all otherLeisure Concepts drawings for area.
All works to be carried out by recommendedinstallation contractors to manufacturer'sinstructions/ recommendations
All work should comply with BS Codes of Practiceand all Statutory Requirements
All dimensions are in millimetres unless statedotherwise.
Set out to be discussed with Interior Designer priorto commencement of works
The Shop Fit trade contractor must familiarisehimself with the site and measure all areas affectinghis work. All dimensions to be verified on site prior tomanufacture of any artefact or works, on or off site.
Samples of all finishes showing realisticinterpretation of material, texture, colour, reflectivityand quality of finishing to be submitted to theDesigner for approval, prior to manufacture.
All softwood units and panelling to be in goodquality, relatively knot-free softwood, clear andbetter, unsorted, with sheet materials faced inveneer to provide a good quality finish whenvarnished.
All edge trims and mouldings to be in solid wood(unless otherwise specified) and finished to match.
Contractor to ensure that timber is Pre-treated asnecessary to comply with F.R requirements ofBuilding Control and all finishes to achieve goodquality appearance as specified by architect.
Carcassing should be non-combustible or becertified as minimum Class 1 Surface Spread ofFlame, in accordance with BS476 Part 7 1971 or1987.
Lighting and small power requirements shown arenot necessarily the total requirements. Service areas, toilets, air handling, Building Regs requirements,specialist contractors' items e.g stage power is to bespecified by "others."
The Contractor is to confirm total requirements withthe M&E Consultant and specialist contractors.
All electrics to comply fully with 17th Edition andlatest updates & amendments as determined byNICEIC