spec guide flex™ system - connectrac

14
FLEX™ SYSTEM For installation under carpet tile SPEC GUIDE Updated 02.12.2021

Upload: others

Post on 15-Mar-2022

39 views

Category:

Documents


0 download

TRANSCRIPT

FLEX™ SYSTEMFor installation under carpet tileSP

EC G

UID

E

Updated02.12.2021

HOW WE CAN HELP

Online

General Info & Questions

Design Team Services

Build your own Flex raceway system using our innovative web tool on the Connectrac website!

Click around and play in this online experience while learning the basics of how Flex works.

connectrac.com/build-your-own

Contact us any time! | 877.480.5637 | [email protected] | connectrac.com

Connectrac® believes in providing exceptional customer service by offering unique resources like our Design Team.

These industry specialists are available to help you specify the best Flex solution for your next project.

connectrac.com/design-services

TABLE OFCONTENTS

What is Flex?How it WorksGet StartedFlex Data Capacity

Pg 4Pg 6Pg 8Pg 9

FLEX SYSTEMFor installation under carpet tile

Connectrac® Flex is...A floor-based power and data distribution system that allows users to quickly add connectivity or change power locations in a snap.

Any Space. Any Building. Any Time.™

HUDDLE

MEET

WORK

4

Interchangeable Power DevicesQuickly snap into any Power Hub location

Connects Powertracs & provides access for power devices

Top Cover & Transition Ramps

(included with raceway)Entrance Fitting

Raceway

Quick connector powers entire raceway & allows

data to enter

Powertrac

Power Hub

Pre-wired raceway segment

Data Device

Explore the graphic to learn more about the Flex system for installation under carpet tile.

HOW IT WORKS

A

B

C

C

Snaps into the raceway to provide data

connectivity

6

FLEX DATA C

APACITY

0-4 cables

5-14 cables

15-24 cables

Turn to Next Page

Turn to Page 16

Turn to Page 22

Plan Flex Raceway System

Optimize Your Raceway Increase your system’s adaptability by adding more points of power access.

GET

STA

RTED

What is the current use of this space? What else might it be used for in the future? How might furniture be rearranged?

TIP: For greater flexibility at minimal cost, add more Power Hubs and connect shorter Powertracs.

Power Hubs = access points for power devices

TIP: Visualize how your space might adapt and evolve over time.

GOOD

BETTER

BEST4

POWER HUBS

3POWER

HUBS

2POWER

HUBS

3’ 3’ 3’

3’6’

6’ 6’

3’

3’

Typical for conference rooms

Typical for up to seven workstations

Typical for up to twelve workstations

How much data do you need?

8 9

FLEX EXAMPLE RUN

In-Wall Entrance Fitting Surface-Mounted Entrance Fitting

Entrance FittingA Choose how your Flex raceways start at the wall.

1

22

11

1

In-Wall Entrance Fitting(15’ pre-wired conduit)

4’ PowertracPower Hub

HubcapReceptacle Device (2-circuit 1, 2-circuit 2)

Data Device

A1.15

B.FX1.4B.HUB

C.HUBCAPC.PW1.12

C.DT2

QTY DESCRIPTIONFLEX CODE

FLEX 0-4 Data C

ables

Entrance FittingA

Raceway B

DevicesC

Flex 0-4 Data Cables

PowertracB.FX1.4

In-Wall Entrance Fitting

A1.15

PowertracB.FX1.4

Power HubB.HUB

Power HubB.HUB

HubcapC.HUBCAP

Data DeviceC.DT2

Receptacle Device

C.PW1.12

Wall Entrance Fitting

A1A2

A

Included with every raceway order:

Top Covers

End Ramps

Transition Ramps

Transition accessories included

Surface-Mounted Entrance FittingIn-Wall Entrance Fitting A2.__A1.__

DESCRIPTIONDESCRIPTION FLEX CODEFLEX CODE

Use when cabling is running OUTSIDE the wall:Use when cabling is running INSIDE the wall:

A2.3A2.15A2.30

A1.15A1.30

3’ pre-wired conduit, 2’ Walltrac15’ pre-wired conduit, 12’ Walltrac30’ pre-wired conduit, 12’ Walltrac

15’ pre-wired conduit30’ pre-wired conduit

Base Trim included

TIP: Use A2.3 to connect to existing wall outlet boxes.

10 11

Powertracs Power Hub

RacewayB Continue to build your raceways by connecting Powertracs and Power Hubs. Equip your Flex raceway system with power & data devices.

TIP: For greater flexibility at minimal cost, add more Power Hubs and connect shorter Powertracs.

*Powertrac measurements are based on the on-center distance between the Entrance Fitting and/or Power Hubs.

Power HubB.FX1.__

B.FX1.EXT

B.FX1.90

B.HUB C.HUBCAP

C.PW1.__

C.PW2.4

DESCRIPTION DESCRIPTIONFLEX CODE FLEX CODE

Powertrac

Powertrac Extender

Powertrac Corner

Power Hub

FLEX

0-4

Dat

a C

able

s FLEX 0-4 Data C

ablesPower Devices

DevicesCChoose which devices (if any) you want to snap into your Power Hubs.

Powertrac

Powertrac Extender

Powertrac Corner

DESCRIPTIONFLEX CODE

Creates a walkable surface and makes power easily accessible for future needs

Quad device available in various 4-circuit options:

4-circuit monument that connects to most furniture base feeds

Pre-wired raceway segmentsavailable in standard lengths:

Connects Powertracs & provides access for power devices

Adds 6” to any of our standard Powertrac lengths

Top Covers & Ramps included

Allows raceway to make a 90° turn

C.PW1.11C.PW1.22C.PW1.33C.PW1.44C.PW1.12*C.PW1.34*C.PW1.14*

B.FX1.2B.FX1.3B.FX1.4B.FX1.5B.FX1.6

2’ Powertrac3’ Powertrac4’ Powertrac5’ Powertrac6’ Powertrac

All circuit 1All circuit 2All circuit 3All circuit 42-circuit 1, 2-circuit 22-circuit 3, 2-circuit 42-circuit 1, 2-circuit 4

Hubcap

Power Hub4’ Powertrac*4’ Powertrac* Power Hub

Receptacle DeviceCB

Receptacle Device

Hardwire Device

Hubcap

Power devices are all interchangeable and can be hot-swapped

when desired.

Hubcap

Receptacle Device

Hardwire Device

Power Hub Power Hub

*Controlled devices available (see Technical Guide for more details)

12 13

Data Devices

DevicesCThese devices go anywhere on the raceway.

Data DeviceC

Equip your Flex raceway system with power & data devices.

C.DT1

C.DT2

DESCRIPTIONFLEX CODE

Allows cables to enter/exit raceway

Fits up to 8 low-voltage keystone modules

Grommet

Data Device

Data DeviceGrommet

Data devices easily snap next to any

power device.

Optional Accessories Enhance your raceways with these additional options.

Extra HubcapVertical Wire Manager Rough-In Frame

VWM

RIF

C.HUBCAP

DESCRIPTIONFLEX CODE

Attaches to any power or data device to manage cabling

Installed before drywall to provide a rough opening for cabling

Creates a walkable surface and makes power easily accessible for future needs

Vertical Wire Manager

Rough-In Frame

Extra Hubcap

Accessories

8’-0”

4’-0” 4’-0”

WALL

Complete Raceway Shown with Top Covers, Transition Ramps, and End Ramps installed.

34”

FLEX

0-4

Dat

a C

able

s FLEX 0-4 Data C

ables

14 15

FLEX EXAMPLE RUN: 5-14 Data Cables

1

22

11

1

In-Wall Entrance Fitting(15’ pre-wired conduit)

4’ PowertracPower Hub

HubcapReceptacle Device (2-circuit 1, 2-circuit 2)

Data Device

A1.15

B.FX2.4B.HUB

C.HUBCAPC.PW1.12

C.DT2

$$$

$$$$$$

$$$$$$

$$$

QTY DESCRIPTIONFLEX CODE PRICE

FLEX 5-14 Data C

ables

Entrance FittingA

Raceway B

DevicesC

Flex 5-14 Data Cables

PowertracB.FX2.4

In-Wall Entrance Fitting

A1.15

PowertracB.FX2.4

Power HubB.HUB

Power HubB.HUB

Data DeviceC.DT2

HubcapC.HUBCAP

Receptacle DeviceC.PW1.12

Included with every raceway order:

Data Channel

End Ramps

Transition Ramps

Top Covers

In-Wall Entrance Fitting Surface-Mounted Entrance Fitting

Entrance FittingA

Wall Entrance Fitting

A1A2

A

Transition accessories included

Surface-Mounted Entrance FittingIn-Wall Entrance FittingA1.__

DESCRIPTIONDESCRIPTION FLEX CODEFLEX CODE

Use when cabling is running OUTSIDE the wall:Use when cabling is running INSIDE the wall:

A2.3A2.15A2.30

A1.15A1.30

3’ pre-wired conduit, 2’ Walltrac15’ pre-wired conduit, 12’ Walltrac30’ pre-wired conduit, 12’ Walltrac

15’ pre-wired conduit30’ pre-wired conduit

Base Trim included

TIP: Use A2.3 to connect to existing wall outlet boxes.

A2.__

Choose how your Flex raceways start at the wall.

16 17

*Powertrac measurements are based on the on-center distance between the Entrance Fitting and/or Power Hubs.

B.FX2.__

B.FX2.EXT

B.FX2.90

FLEX

5-1

4 D

ata

Cab

les

Top Covers, Data Channel & Ramps included

Datatrac Corner included

B.FX2.2B.FX2.3B.FX2.4B.FX2.5B.FX2.6

2’ Powertrac3’ Powertrac4’ Powertrac5’ Powertrac6’ Powertrac

HubcapPower Hub4’ Powertrac*4’ Powertrac* Power HubReceptacle DeviceCB

Power Hub Power Hub

FLEX 5-14 Data C

ablesPowertracs Power Hub

RacewayB

TIP: For greater flexibility at minimal cost, add more Power Hubs and connect shorter Powertracs.

Power HubB.HUB

DESCRIPTION DESCRIPTIONFLEX CODE FLEX CODE

Powertrac

Powertrac Extender

Powertrac Corner

Power Hub

Powertrac

Powertrac Extender

Powertrac Corner

Pre-wired raceway segmentsavailable in standard lengths:

Adds 6” to any of our standard Powertrac lengths

Allows raceway to make a 90° turn

C.HUBCAP

C.PW1.__

C.PW2.4

Power Devices

DevicesCChoose which devices (if any) you want to snap into your Power Hubs.

DESCRIPTIONFLEX CODE

Creates a walkable surface and makes power easily accessible for future needs

C.PW1.11C.PW1.22C.PW1.33C.PW1.44C.PW1.12*C.PW1.34*C.PW1.14*

All circuit 1All circuit 2All circuit 3All circuit 42-circuit 1, 2-circuit 22-circuit 3, 2-circuit 42-circuit 1, 2-circuit 4

Receptacle Device

Hardwire Device

Hubcap

Power devices are all interchangeable and can be hot-swapped

when desired.

Hubcap

Receptacle Device

Hardwire Device

Continue to build your raceways by connecting Powertracs and Power Hubs.

Connects Powertracs & provides access for power devices

Equip your Flex raceway system with power & data devices.

4-circuit monument that connects to most furniture base feeds

*Controlled devices available (see Technical Guide for more details)

Quad device available in various 4-circuit options:

18 19

Data DeviceC

8’-0”

4’-0” 4’-0”

WALL

38”

FLEX 5-14 Data C

ablesFLEX

5-1

4 D

ata

Cab

les

Data Devices

DevicesC

C.DT1

C.DT2

DESCRIPTIONFLEX CODE

Allows cables to enter/exit racewayGrommet

Data Device

Data DeviceGrommet

Optional Accessories Enhance your raceways with these additional options.

Extra HubcapVertical Wire Manager Rough-In Frame

VWM

RIF

C.HUBCAP

DESCRIPTIONFLEX CODE

Attaches to any power or data device to manage cabling

Installed before drywall to provide a rough opening for cabling

Creates a walkable surface and makes power easily accessible for future needs

Vertical Wire Manager

Rough-In Frame

Extra Hubcap

Accessories

Complete Raceway Shown with Top Covers, Transition Ramps, and End Ramps installed.

Equip your Flex raceway system with power & data devices.

Fits up to 8 low-voltage keystone modules

These devices go anywhere on the raceway.

Data devices easily snap next to any

power device.

20 21

FLEX EXAMPLE RUN: 15-24 Data Cables

1

22

11

2

In-Wall Entrance Fitting(15’ pre-wired conduit)

4’ PowertracPower Hub

HubcapReceptacle Device (2-circuit 1, 2-circuit 2)

Data Device

A1.15

B.FX3.4B.HUB

C.HUBCAPC.PW1.12

C.DT2

$$$

$$$$$$

$$$$$$

$$$

QTY DESCRIPTIONFLEX CODE PRICE

Entrance FittingA

Raceway B

DevicesC

Flex 15-24 Data Cables

PowertracB.FX3.4

PowertracB.FX3.4

Power HubB.HUB

Power HubB.HUB

Data DeviceC.DT2

ReceptacleDevice

C.PW1.12

Included with every raceway order:

Data Channels

End Ramps

Transition Ramps

Top Covers

In-Wall Entrance Fitting

A1.15

HubcapC.HUBCAP

FLEX 15-24 Data C

ables

In-Wall Entrance Fitting Surface-Mounted Entrance Fitting

Entrance FittingA

Wall Entrance Fitting

A1A2

A

Transition accessories included

Surface-Mounted Entrance FittingIn-Wall Entrance FittingA1.__

DESCRIPTIONDESCRIPTION FLEX CODEFLEX CODE

Use when cabling is running OUTSIDE the wall:Use when cabling is running INSIDE the wall:

A2.3A2.15A2.30

A1.15A1.30

3’ pre-wired conduit, 2’ Walltrac15’ pre-wired conduit, 12’ Walltrac30’ pre-wired conduit, 12’ Walltrac

15’ pre-wired conduit30’ pre-wired conduit

Base Trim included

TIP: Use A2.3 to connect to existing wall outlet boxes.

A2.__

Choose how your Flex raceways start at the wall.

22 23

*Powertrac measurements are based on the on-center distance between the Entrance Fitting and/or Power Hubs.

B.FX3.__

B.FX3.EXT

B.FX3.90

FLEX

15-

24 D

ata

Cab

les

Datatrac Corners included

B.FX3.2B.FX3.3B.FX3.4B.FX3.5B.FX3.6

2’ Powertrac3’ Powertrac4’ Powertrac5’ Powertrac6’ Powertrac

HubcapPower Hub4’ Powertrac*4’ Powertrac* Power Hub

Receptacle DeviceCB

Power Hub Power Hub

FLEX 15-24 Data C

ablesPowertracs Power Hub

RacewayB

TIP: For greater flexibility at minimal cost, add more Power Hubs and connect shorter Powertracs.

Power HubB.HUB

DESCRIPTION DESCRIPTIONFLEX CODE FLEX CODE

Powertrac

Powertrac Extender

Powertrac Corner

Power Hub

Powertrac

Powertrac Extender

Powertrac Corner

Pre-wired raceway segmentsavailable in standard lengths:

Adds 6” to any of our standard Powertrac lengths

Allows raceway to make a 90° turn

C.HUBCAP

C.PW1.__

C.PW2.4

Power Devices

DevicesCChoose which devices (if any) you want to snap into your Power Hubs.

DESCRIPTIONFLEX CODE

Creates a walkable surface and makes power easily accessible for future needs

C.PW1.11C.PW1.22C.PW1.33C.PW1.44C.PW1.12*C.PW1.34*C.PW1.14*

All circuit 1All circuit 2All circuit 3All circuit 42-circuit 1, 2-circuit 22-circuit 3, 2-circuit 42-circuit 1, 2-circuit 4

Receptacle Device

Hardwire Device

Hubcap

Power devices are all interchangeable and can be hot-swapped

when desired.

Hubcap

Receptacle Device

Hardwire Device

Top Covers, Data Channels & Ramps included

Continue to build your raceways by connecting Powertracs and Power Hubs.

Connects Powertracs & provides access for power devices

Equip your Flex raceway system with power & data devices.

4-circuit monument that connects to most furniture base feeds

*Controlled devices available (see Technical Guide for more details)

Quad device available in various 4-circuit options:

24 25

Data DevicesC

8’-0”

4’-0” 4’-0”

WALL

42”

FLEX 15-24 Data C

ablesFLEX

15-

24 D

ata

Cab

les

Data Devices

DevicesC

C.DT1

C.DT2

DESCRIPTIONFLEX CODE

Allows cables to enter/exit racewayGrommet

Data Device

Data DeviceGrommet

Optional Accessories Enhance your raceways with these additional options.

Extra HubcapVertical Wire Manager Rough-In Frame

VWM

RIF

C.HUBCAP

DESCRIPTIONFLEX CODE

Attaches to any power or data device to manage cabling

Installed before drywall to provide a rough opening for cabling

Creates a walkable surface and makes power easily accessible for future needs

Vertical Wire Manager

Rough-In Frame

Extra Hubcap

Accessories

Complete Raceway Shown with Top Covers, Transition Ramps, and End Ramps installed.

Equip your Flex raceway system with power & data devices.

Fits up to 8 low-voltage keystone modules

These devices go anywhere on the raceway.

Data devices easily snap next to any

power device.

26 27