specialized aircraft rescue fire simulator · pdf filenarrow-body exterior arff simulator...
TRANSCRIPT
S P E C I A L I Z E D A I R C R A F T R E S C U E F I R E S I M U L A T O R
FIXED FACILITY A320 CONFIGURATION
1. Full-scale Narrow-body Aircraft Model
• All steel construction
• Produced in modular components offsite
• Onsite final assembly
• Interior layout simulates narrow body
• Constructed in accordance with governing codes
3. Multiple Live Fire Simulators
• LPG vapor propane-fueled
• Cockpit Live Fire SIM
• Passenger Compartment Live Fire SIM
• Main Cabin Flashover Live Fire SIM
• Cargo Live Fire SIM
• Gallery Live Fire SIM
• Lavatory Live Fire SIM
• APU Live Fire SIM
• Landing Gear Live Fire SIM
• Wing Engine Live Fire SIM
Training System Objectives
� Operating key ARFF equipment� Executing normal ARFF incident procedures� Executing corresponding ARFF integrated fire suppression
and rescue drills � Executing ARFF incident command� Familiarization with narrow body aircraft interiors, exteriors,
hatches, doors, and access points� Familiarization with typical narrow body aircraft fire locations
and flame spreads characteristics
Basic System Configuration
� Full scale narrow-body aircraft mock-up, constructed of steel� Fully integrated LIVE FIRE burning props, fuel supply system
and control systems for multiple fire scenarios� Water delivery and reclamation system� Multi-layered safety system with multiple-levels of monitoring
and emergency training shutoffs � Computer-based ignition, control, ARFF scenario
management, safety monitoring and action recording systems � Command tower with visual and video observation, computer
monitoring systems and controls� Hardware and software including operations and
maintenance documentation� Installation and testing� One year parts and service warranty� Technical handover to training facility operator
Additional Training System Options
� Multiple fire zones� Multiple levels of flame control
1
SUMMARY INFORMATION
2
3
2. Achievable Training Objectives
• Aircraft entry
• Passenger search and rescue
• ARFF recovery training
• Fuselage penetration training
• Aircraft familiarization
• Hose line use and proper extinguishing agents
4
Confidential Property of the VSD Fire Fighting & Emergency Response Consortium n, LLC © 2012.
4. Interior Configuration
• Replicated cockpit with seating
• Reconfigurable passenger seating
• Cargo hold area
• Baggage hold area
• Galley placement
• Lavatory placement
6. Safety Features
• Exhaust Systems
• Fail safe safety shut downs
• E-stop Buttons at critical points
• LEL Monitoring
• Temperature Monitoring
• Pilot and flame monitoring of all zones
8. Control Tower
• PC Control Systems
• Video monitoring of entire site
• Full controls of all areas
• Safety shutdowns
• Communications systems
� Multiple levels of flame control� Multiple levels of smoke distribution
Training Delivery Options
� Curricula for classroom, simulator, and ARFF equipment familiarization training
� Certified instructors for classroom, simulator, and live fire training
� Training facility operations and maintenance service
F I R E F I G H TI N G & E ME R G E N C Y R E S P O N S E TR A I N I N G
S O L U TI O N S
SPECIALIZED AIRCRAFT TRAINING
4
5
7
5. Smoke and ventilation system
• Smoke distribution system
• To zero visibility in under 60 seconds
• Complete air exchange in under 60 seconds
7. Training Software
• Embedded programming and control screens
• Password and user protected
• Programmable gas flow and flame levels
• Full data tracking
6
8
N A R R O W - B O D Y E X T E R I O R A R F F S I M U L A T O R
F I X E D F A C I L I T Y B O E I N G 7 3 7 C O N F I G U R A T I O N
3. Multiple Live Fire Simulators
• LPG liquid propane-fueled
• Multi Zone Fuel Spill Live Fire SIM
• Class B Fuselage Live Fire SIM
• Wing Engine Live Fire SIM
1
SUMMARY INFORMATION
2 3
2. Achievable Training Objectives
• Fuel spill fire control
• Aircraft entry
• ARFF recovery training
• Aircraft familiarization
• Hose line use and proper extinguishing agents
4
8
8. Empirical Fire Zone
Training System Objectives
� Operating key ARFF equipment � Executing normal ARFF incident procedures� Executing corresponding ARFF integrated fire suppression
and rescue drills � Executing ARFF incident command� Familiarization with narrow body aircraft interiors, exteriors,
hatches, doors, and access points� Familiarization with typical narrow body aircraft fire locations
and flame spreads characteristics� 11,000 sq ft flammable spill zone� Multi zone pre programmable fuel spill fire
Basic System Configuration
� Full scale narrow-body aircraft mock-up, constructed of steel� Fully integrated LIVE FIRE Fuel Spill, fuel supply system and
control systems for multiple zone fire scenarios� Water delivery and reclamation system� Multi-layered safety system with multiple-levels of monitoring
and emergency training shutoffs � Computer-based ignition, control, ARFF scenario
management, safety monitoring and action recording systems � Command tower with visual and video observation, computer
monitoring systems and controls� Hardware and software including operations and
maintenance documentation� Installation and testing� One year parts and service warranty� Technical handover to training facility operator
Additional Training System Options
1.Full-scale Narrow-body Aircraft Model
• All steel construction
• Produced in modular components offsite
• Onsite final assembly
• Exterior simulates narrow body downed aircraft
• Constructed in accordance with governing codes
Confidential Property of the VSD Fire Fighting & Emergency Response Consortium n, LLC © 2012.
4. Interior Configuration
• Replicated cockpit with seating
• Reconfigurable passenger seating
• Cargo compartment with storage containers
5. Safety Features
• E-stop Buttons at critical points
• Pilot and flame burner management
• Vault Air flow management
7. Control Tower
• PC Control Systems
• Video monitoring of entire site
• Full controls of all areas
• Safety shutdowns
• Communications systems
F I R E F I G H TI N G & E ME R G E N C Y R E S P O N S E TR A I N I N G
S O L U TI O N S
FIXED EXTERIOR NARROW-BODY AIRCRAFT
5
7
6
8. Empirical Fire Zone
• Wide zone surrounding aircraft
• Water reclamation system
• LPG fuel pump delivery system
Additional Training System Options
� Multiple fire zones� Multiple levels of flame control� Multiple levels of smoke distribution
Training Delivery Options
� Curricula for classroom, simulator, and ARFF equipment familiarization training
� Certified instructors for classroom, simulator, and live fire training
� Training facility operations and maintenance service
6.Training Software
• Embedded programming and control screens
• Password and user protected
• Programmable gas flow and flame levels
• Full data tracking