specialized aircraft rescue fire simulator · pdf filenarrow-body exterior arff simulator...

2
SPECIALIZED AIRCRAFT RESCUE FIRE SIMULATOR FIXED FACILITY A320 CONFIGURATION 1. Full-scale Narrow-body Aircraft Model All steel construction Produced in modular components offsite Onsite final assembly Interior layout simulates narrow body Constructed in accordance with governing codes 3. Multiple Live Fire Simulators LPG vapor propane-fueled Cockpit Live Fire SIM Passenger Compartment Live Fire SIM Main Cabin Flashover Live Fire SIM Cargo Live Fire SIM Gallery Live Fire SIM Lavatory Live Fire SIM APU Live Fire SIM Landing Gear Live Fire SIM Wing Engine Live Fire SIM Training System Objectives Operating key ARFF equipment Executing normal ARFF incident procedures Executing corresponding ARFF integrated fire suppression and rescue drills Executing ARFF incident command Familiarization with narrow body aircraft interiors, exteriors, hatches, doors, and access points Familiarization with typical narrow body aircraft fire locations and flame spreads characteristics Basic System Configuration Full scale narrow-body aircraft mock-up, constructed of steel Fully integrated LIVE FIRE burning props, fuel supply system and control systems for multiple fire scenarios Water delivery and reclamation system Multi-layered safety system with multiple-levels of monitoring and emergency training shutoffs Computer-based ignition, control, ARFF scenario management, safety monitoring and action recording systems Command tower with visual and video observation, computer monitoring systems and controls Hardware and software including operations and maintenance documentation Installation and testing One year parts and service warranty Technical handover to training facility operator Additional Training System Options Multiple fire zones Multiple levels of flame control 1 SUMMARY INFORMATION 2 3 2. Achievable Training Objectives Aircraft entry Passenger search and rescue ARFF recovery training Fuselage penetration training Aircraft familiarization Hose line use and proper extinguishing agents 4 Confidential Property of the VSD Fire Fighting & Emergency Response Consortium n, LLC © 2012. 4. Interior Configuration Replicated cockpit with seating Reconfigurable passenger seating Cargo hold area Baggage hold area Galley placement Lavatory placement 6. Safety Features Exhaust Systems Fail safe safety shut downs E-stop Buttons at critical points LEL Monitoring Temperature Monitoring Pilot and flame monitoring of all zones 8. Control Tower PC Control Systems Video monitoring of entire site Full controls of all areas Safety shutdowns Communications systems Multiple levels of flame control Multiple levels of smoke distribution Training Delivery Options Curricula for classroom, simulator, and ARFF equipment familiarization training Certified instructors for classroom, simulator, and live fire training Training facility operations and maintenance service FIRE FIGHTING & EMERGENCY RESPONSE TRAINING SOLUTIONS SPECIALIZED AIRCRAFT TRAINING 4 5 7 5. Smoke and ventilation system Smoke distribution system To zero visibility in under 60 seconds Complete air exchange in under 60 seconds 7. Training Software Embedded programming and control screens Password and user protected Programmable gas flow and flame levels Full data tracking 6 8

Upload: hoangliem

Post on 27-Mar-2018

223 views

Category:

Documents


2 download

TRANSCRIPT

S P E C I A L I Z E D A I R C R A F T R E S C U E F I R E S I M U L A T O R

FIXED FACILITY A320 CONFIGURATION

1. Full-scale Narrow-body Aircraft Model

• All steel construction

• Produced in modular components offsite

• Onsite final assembly

• Interior layout simulates narrow body

• Constructed in accordance with governing codes

3. Multiple Live Fire Simulators

• LPG vapor propane-fueled

• Cockpit Live Fire SIM

• Passenger Compartment Live Fire SIM

• Main Cabin Flashover Live Fire SIM

• Cargo Live Fire SIM

• Gallery Live Fire SIM

• Lavatory Live Fire SIM

• APU Live Fire SIM

• Landing Gear Live Fire SIM

• Wing Engine Live Fire SIM

Training System Objectives

� Operating key ARFF equipment� Executing normal ARFF incident procedures� Executing corresponding ARFF integrated fire suppression

and rescue drills � Executing ARFF incident command� Familiarization with narrow body aircraft interiors, exteriors,

hatches, doors, and access points� Familiarization with typical narrow body aircraft fire locations

and flame spreads characteristics

Basic System Configuration

� Full scale narrow-body aircraft mock-up, constructed of steel� Fully integrated LIVE FIRE burning props, fuel supply system

and control systems for multiple fire scenarios� Water delivery and reclamation system� Multi-layered safety system with multiple-levels of monitoring

and emergency training shutoffs � Computer-based ignition, control, ARFF scenario

management, safety monitoring and action recording systems � Command tower with visual and video observation, computer

monitoring systems and controls� Hardware and software including operations and

maintenance documentation� Installation and testing� One year parts and service warranty� Technical handover to training facility operator

Additional Training System Options

� Multiple fire zones� Multiple levels of flame control

1

SUMMARY INFORMATION

2

3

2. Achievable Training Objectives

• Aircraft entry

• Passenger search and rescue

• ARFF recovery training

• Fuselage penetration training

• Aircraft familiarization

• Hose line use and proper extinguishing agents

4

Confidential Property of the VSD Fire Fighting & Emergency Response Consortium n, LLC © 2012.

4. Interior Configuration

• Replicated cockpit with seating

• Reconfigurable passenger seating

• Cargo hold area

• Baggage hold area

• Galley placement

• Lavatory placement

6. Safety Features

• Exhaust Systems

• Fail safe safety shut downs

• E-stop Buttons at critical points

• LEL Monitoring

• Temperature Monitoring

• Pilot and flame monitoring of all zones

8. Control Tower

• PC Control Systems

• Video monitoring of entire site

• Full controls of all areas

• Safety shutdowns

• Communications systems

� Multiple levels of flame control� Multiple levels of smoke distribution

Training Delivery Options

� Curricula for classroom, simulator, and ARFF equipment familiarization training

� Certified instructors for classroom, simulator, and live fire training

� Training facility operations and maintenance service

F I R E F I G H TI N G & E ME R G E N C Y R E S P O N S E TR A I N I N G

S O L U TI O N S

SPECIALIZED AIRCRAFT TRAINING

4

5

7

5. Smoke and ventilation system

• Smoke distribution system

• To zero visibility in under 60 seconds

• Complete air exchange in under 60 seconds

7. Training Software

• Embedded programming and control screens

• Password and user protected

• Programmable gas flow and flame levels

• Full data tracking

6

8

N A R R O W - B O D Y E X T E R I O R A R F F S I M U L A T O R

F I X E D F A C I L I T Y B O E I N G 7 3 7 C O N F I G U R A T I O N

3. Multiple Live Fire Simulators

• LPG liquid propane-fueled

• Multi Zone Fuel Spill Live Fire SIM

• Class B Fuselage Live Fire SIM

• Wing Engine Live Fire SIM

1

SUMMARY INFORMATION

2 3

2. Achievable Training Objectives

• Fuel spill fire control

• Aircraft entry

• ARFF recovery training

• Aircraft familiarization

• Hose line use and proper extinguishing agents

4

8

8. Empirical Fire Zone

Training System Objectives

� Operating key ARFF equipment � Executing normal ARFF incident procedures� Executing corresponding ARFF integrated fire suppression

and rescue drills � Executing ARFF incident command� Familiarization with narrow body aircraft interiors, exteriors,

hatches, doors, and access points� Familiarization with typical narrow body aircraft fire locations

and flame spreads characteristics� 11,000 sq ft flammable spill zone� Multi zone pre programmable fuel spill fire

Basic System Configuration

� Full scale narrow-body aircraft mock-up, constructed of steel� Fully integrated LIVE FIRE Fuel Spill, fuel supply system and

control systems for multiple zone fire scenarios� Water delivery and reclamation system� Multi-layered safety system with multiple-levels of monitoring

and emergency training shutoffs � Computer-based ignition, control, ARFF scenario

management, safety monitoring and action recording systems � Command tower with visual and video observation, computer

monitoring systems and controls� Hardware and software including operations and

maintenance documentation� Installation and testing� One year parts and service warranty� Technical handover to training facility operator

Additional Training System Options

1.Full-scale Narrow-body Aircraft Model

• All steel construction

• Produced in modular components offsite

• Onsite final assembly

• Exterior simulates narrow body downed aircraft

• Constructed in accordance with governing codes

Confidential Property of the VSD Fire Fighting & Emergency Response Consortium n, LLC © 2012.

4. Interior Configuration

• Replicated cockpit with seating

• Reconfigurable passenger seating

• Cargo compartment with storage containers

5. Safety Features

• E-stop Buttons at critical points

• Pilot and flame burner management

• Vault Air flow management

7. Control Tower

• PC Control Systems

• Video monitoring of entire site

• Full controls of all areas

• Safety shutdowns

• Communications systems

F I R E F I G H TI N G & E ME R G E N C Y R E S P O N S E TR A I N I N G

S O L U TI O N S

FIXED EXTERIOR NARROW-BODY AIRCRAFT

5

7

6

8. Empirical Fire Zone

• Wide zone surrounding aircraft

• Water reclamation system

• LPG fuel pump delivery system

Additional Training System Options

� Multiple fire zones� Multiple levels of flame control� Multiple levels of smoke distribution

Training Delivery Options

� Curricula for classroom, simulator, and ARFF equipment familiarization training

� Certified instructors for classroom, simulator, and live fire training

� Training facility operations and maintenance service

6.Training Software

• Embedded programming and control screens

• Password and user protected

• Programmable gas flow and flame levels

• Full data tracking