specification sheet lumenline 2 -...

16
PENDANT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES EM - R23 1/16 2016.07.28 Specification Sheet lumenline 2 5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2016 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. AIRCRAFT CABLE LENGTH IS FIELD ADJUSTABLE UP TO 250" FRONT VIEW SIDE VIEW TOP VIEW, WIDE FLOOD OPTIC SHOWN BOTTOM VIEW, WIDE FLOOD OPTIC SHOWN [68mm] 11 16 " 2 [115mm] 9 16 " 4 [317mm, 616mm, 916mm, 1216mm, 1518mm, 1818mm, 2119mm, 2419mm] 1 2 " 1 4 " 12 , 24 1 " , 36 7 8 16 " , 47 3 4 " , 59 9 16 " , 71 3 8 " , 83 1 4 " , 95 Direct wide flood Direct true asymmetric wallwash Direct narrow flood Optic Delivered output [lm/ft] Lumens/ Watt [lm/W] 492 391 398 Indirect batwing wide 479 87 71 73 Indirect wide flood* 522 93 88 Performance summary Based on RO, all color temperatures, White painted louver for NF and WW optics. Photometric performance is measured in compliance with IESNA LM-79-08. *Estimated. Consult website for latest ies files. FEATURES AND BENEFITS Physical : Aluminum extruded housing, 2” wide Available in 1’, 2’, 3’, 4’, 5’, 6’, 7’ or 8’ sections Continuous runs available in 1’ increments Durable polyester powder coat finish Wide flood, true asymmetric wallwash or narrow flood direct lighting optics Batwing wide or wide flood indirect lighting optics Wallwash and narrow flood optics provided with white painted louvers Black painted or semi-specular louver finish optional Wide flood optic provided with frosted extruded acrylic lens Tool-less system for reflector assembly and control gear access Suitable for use with drywall, grid and metal pan ceilings (millwork ceilings) Aircraft cable adjustable suspension system Lit and unlit joiners available for custom configurations Compatible with motion sensors • Dry location only • IK05 rated Performance : Available in 2700K, 3000K, 3500K, 4000K or RGB color mixing for direct and indirect lighting Binning within a 3 step MacAdam ellipse Lumen maintenance: 100,000 hrs [L70 @ 25° C] Lumen measurements comply with LM - 79 - 08 standard Resolution per foot or per fixture (configured with LumenID V3 software & DMX/RDM) Operating temperatures: -25° C to 50° C [-13F to 122F] Electrical : Line voltage luminaire for 100 to 347V Standard white cable and canopy, consult factory for other options 6W/ft Regular Output version, direct or indirect lighting 12W/ft High Output version, direct or indirect lighting Dimming options for white light: 0-10 volt, DMX/RDM enabled, DALI, Lumentalk or Lutron® EcoSystem® Enabled 6W/ft optional RGB source, DMX/RDM enabled Quick connectors for continuous runs Client Project name Order# Type Qty Narrow flood (30 ˚ x 60 ˚ ) Wide flood (100 ˚ ) Direct Wide flood (100 ˚ ) Indirect Batwing wide (170 ˚ ) True asymmetric wallwash CERTIFICADO No.05884, 05885 RETILAP IK05

Upload: nguyenthuy

Post on 30-Apr-2018

221 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

1/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

AIRCRAFT CABLELENGTH IS FIELD

ADJUSTABLE UP TO 250"

FRONT VIEW

SIDE VIEW

TOP VIEW, WIDE FLOOD OPTIC SHOWN

BOTTOM VIEW, WIDE FLOOD OPTIC SHOWN

[68mm]

11 16

"2

[115mm]

9 16

"4

[317mm, 616mm, 916mm, 1216mm, 1518mm, 1818mm, 2119mm, 2419mm]

1 2

" 1 4

"12 , 24 1 ", 36 7 8 16

", 47 3 4

", 59 9 16

", 71 3 8

", 83 1 4

", 95

Direct wide flood

Direct trueasymmetric wallwash

Direct narrow flood

OpticDelivered

output [lm/ft]Lumens/

Watt [lm/W]

492

391

398

Indirect batwing wide 479

87

71

73

Indirect wide flood* 522 93

88

Performance summaryBased on RO, all color temperatures,

White painted louver for NF and WW optics.

Photometric performance is measured incompliance with IESNA LM-79-08.

*Estimated. Consult website for latest ies files.

FEATURES AND BENEFITS

Physical :• Aluminum extruded housing, 2” wide• Available in 1’, 2’, 3’, 4’, 5’, 6’, 7’ or 8’ sections• Continuous runs available in 1’ increments•  Durable polyester powder coat finish•  Wide flood, true asymmetric wallwash or narrow flood direct lighting optics•  Batwing wide or wide flood indirect lighting optics•  Wallwash and narrow flood optics provided with white painted louvers •  Black painted or semi-specular louver finish optional•  Wide flood optic provided with frosted extruded acrylic lens •  Tool-less system for reflector assembly and control gear access•  Suitable for use with drywall, grid and metal pan ceilings (millwork ceilings)•  Aircraft cable adjustable suspension system•  Lit and unlit joiners available for custom configurations• Compatible with motion sensors• Dry location only• IK05 rated Performance :• Available in 2700K, 3000K, 3500K, 4000K or RGB color mixing for direct and indirect lighting• Binning within a 3 step MacAdam ellipse• Lumen maintenance: 100,000 hrs [L70 @ 25° C]• Lumen measurements comply with LM - 79 - 08 standard•  Resolution per foot or per fixture (configured with LumenID V3 software & DMX/RDM)• Operating temperatures: -25° C to 50° C [-13F to 122F]

Electrical :•  Line voltage luminaire for 100 to 347V•  Standard white cable and canopy, consult factory for other options•  6W/ft Regular Output version, direct or indirect lighting•  12W/ft High Output version, direct or indirect lighting•  Dimming options for white light: 0-10 volt, DMX/RDM enabled, DALI, Lumentalk or Lutron® EcoSystem® Enabled•  6W/ft optional RGB source, DMX/RDM enabled•  Quick connectors for continuous runs

Client Project name

Order# Type Qty

Narrow flood(30˚ x 60˚)

Wide flood (100˚)Direct

Wide flood (100˚)Indirect

Batwing wide (170˚)

True asymmetricwallwash

CERTIFICADO No.05884,05885

RETILAP

IK05

Page 2: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

2/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

PHOTOMETRIC INFORMATION - DIRECT LIGHTING OPTICS

WFL - Wide flood (100°), all color temperatures

Bottom view,frosted lens

1969

357

HORO

Delivered output, 4f fixture [lm]

White light

RGB

3727

N/A

CRI Value: 80+

WW - True asymmetric wallwash, all color temperaturesNot available for RGB or lit joiners

Bottom view,wallwash louver

NF - Narrow flood (30°x 60°), all color temperaturesNot available for RGB or lit joiners

Bottom View,narrow flood louver

1591

1042*

HORO

Delivered output, 4f fixture [lm]

White louver

Black louver

Semi-specular

2957

1894

1829* 3325

CRI Value: 80+

Candlepower distribution4ft, HO

439

878

1317

1756

1564

1174*

HORO

Delivered output, 4f fixture [lm]

White louver

Black louver

Semi-specular

2783

2135

- -

CRI Value: 80+

4ft, HOBlack louver

903

1805

2708

3610

Candlepower distribution4ft, HOWhite louver

964

1928

2891

3855

0˚-180˚ 90˚-270˚

Semi-specular louver

1014

2028

3042

4056

0˚-180˚ 90˚-270˚

Black louver

802

1605

2407

3209

0˚-180˚ 90˚-270˚

Candlepower distribution,4ft, HOWhite louver

878

1755

2633

3510

Notes:*Estimated. Consult website for latest ies fi les.

Page 3: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

3/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

PHOTOMETRIC INFORMATION - INDIRECT LIGHTING OPTICS

WFL - Wide flood (100°), all color temperatures*

Top view,clear lens

Candlepower distribution4ft, HO

2025

480

HORO

Delivered output, 4f fixture [lm]

White light

RGB

3969

N/A

CRI Value: 80+

BWW - Batwing wide (170°), all color temperatures

Top view,Batwing optic

Candlepower distribution4ft, HO

392

785

1177

1569 1915

-

HORO

Delivered output, 4f fixture [lm]

White light

RGB

3501

N/A

CRI Value: 80+

404

809

1213

1618

Notes:*Estimated. Consult website for latest ies fi les.

Page 4: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

4/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

LOUVER INSTALLATION DETAIL

BATWING WIDE OPTIC - INSTALLATION GUIDELINES

BOTTOM VIEW

Always position louver blades toward the wall

BOTTOM VIEW

Symmetrical louver design, no specific orientation required

Suggested setback 1/7 of the wall height.Example: 1' 5" [432mm] setback for a10ft [3048mm] wall.

True Asymmetric Wallwash

Narrow Flood

Standard feeding side(left hand side when facing the wall)

Minimum mounting height from ceiling is 12" [305mm].

FRONT VIEW

TOP VIEW

TOP VIEW

12ft [3.6m] spacing between rows.

Page 5: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

5/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

SUSPENSION SYSTEM MOUNTING ACCESSORIESIncluded

Drywall ceiling accessories

Non-feeder canopy[51mm]

"2

1/4-20 hardware(by others)

Feeder canopyPower only

[127mm]"5

4"x4" j-boxrequired(by others)

Feeder canopyPower and data

[127mm]"5

4"x4" j-boxrequired(by others)

Non-feeder canopy

T-bar mounting clip and fastner included

[51mm]"2

Suspended ceiling accessories

Feeder canopyPower and data

[127mm]"5

Suspended ceilingj-box (by others)

T-bar mounting clip and fastner included

[127mm]"5

Suspended ceilingj-box (by others)

Feeder canopyPower only

T-bar mounting clip and fastner included

*In continuous runs, a minimum of 1 hanging point per fixture is required.

Page 6: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

6/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

LIT JOINER TYPES AND DIMENSIONSRefer to the SHAPE ordering pageNot available for true asymmetric wallwash and narrow flood optics

3138

"

[797mm]

14 38"

[365mm] 14 38

"

[365mm]

14 38"

[365mm]14 3

8"

[365mm]

31 38

"

[797mm]

17"[432mm]

14 38 "

[365mm]

HCNRHorizontal 90o

Used to build square, rectangle and “L” shapes(Equivalent of a 4’ fixture)

TCNRTee 90o

(Equivalent of a 6’ fixture)

CCNRCross 90o

(Equivalent of an 8’ fixture)

TOP VIEW TOP VIEW

TOP VIEW

Page 7: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

7/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

CNRCorner 90o

TEETee 90o

LNRLinear 180o

CROCross 90o

UNLIT JOINER TYPES AND DIMENSIONSRefer to the SHAPE ordering page

AA

CC

DD

BB*

FIRST OR END OF RUN - Mounting points on fixture and joiner*N.B. Mounting point corresponding to feeder cable location cannot be moved.

MIDDLE OF RUN - Mounting points on joiners

FF GG HH

1 2 "

[13mm]

11132 "

[34mm]

CONTINUOUS RUN - Mounting points on fixtures and joinersMIDDLE OF RUN

Overall length(AA)

Center to center of mounting points (BB)

Minimum Maximum

38 1/2'' [977mm]3'

26 5/8'' [677mm]2'14 7/8'' [379mm]1'

50 5/16' [1279mm]

5' 62 1/16'' [1578mm]

6'

85 13/16'' [2181mm]7'

73 15/16'' [1879mm]

97 5/8'' [2481mm]

36 7/16'' [926mm]

24 5/8'' [628mm]

12 7/8'' [327mm]

48 5/16' [1227mm]

60 1/16'' [1526mm]

83 13/16'' [2129mm]

71 15/16'' [1828mm]

95 5/8'' [2429mm]

30 7/16'' [773mm]

20 5/8'' [524mm]

11'' [280mm]

36 5/16' [923mm]

48 1/16'' [1221mm]

67 13/16'' [1723mm]

55 15/16'' [1421mm]

71 5/8'' [1820mm]8'

4'

Fixturelength

Overall length(CC)

Center to center of mounting points (DD)

40 7/8'' [1039mm]3'

29 1/16'' [739mm]2'17 5/16'' [440mm]1'

52 3/4' [1340mm]

5' 64 1/2'' [1639mm]

6'

88 1/4'' [2242mm]7'

76 3/8'' [1940mm]

100 1/16'' [2542mm]

38 3/16'' [970mm]

26 3/8'' [670mm]

14 5/8'' [372mm]

50 1/16' [1272mm]

61 13/16'' [1571mm]

85 9/16'' [2174mm]

73 11/16'' [1872mm]

97 3/8'' [2474mm]8'

4'

35 1/8'' [892mm]3'

23 5/16'' [592mm]2'11 9/16'' [293mm]1'

47'' [1194mm]

5' 58 3/4'' [1492mm]

6'

82 1/2'' [2095mm]7'

70 5/8'' [1794mm]

94 5/16'' [2395mm]

38 5/8'' [981mm]

25 13/16'' [656mm]

15 1/16'' [383mm]

50 1/2' [1283mm]

62 1/4'' [1581mm]

86'' [2184mm]

74 1/8'' [1283mm]

97 13/16'' [2484mm]8'

4'

(FF) (GG) (HH)

35 1/2'' [902mm]

23 11/16'' [602mm]

11 15/16'' [303mm]

47 3/8'' [1203mm]

59 1/8'' [1502mm]

82 7/8'' [2105mm]

71'' [1803mm]

94 11/16'' [2405mm]

Fixturelength

Fixturelength

Center to center of mounting points

UNLIT JOINER MOUNTING POINT LOCATIONS

*Consult factory for shapes requiring the LNR joiner. 

Page 8: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

8/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

ACCESSORIESOrder separately

Control Systems:LTO2 Lumentouch is a wall mount DMX 512 controller keypad.

LCU Lumencue is a USB / mini SD DMX 512 controller.

LID LumenID is a diagnostic and addressing DMX 512 controller.It must be specifi ed on all DMX applications.Refer to LID specifi cation sheet for details.

LTN Lumentone is a simple pre-programmed DMX 512 controllerwith a push button rotary dial and live feedback.

Control Boxes:CBX DMX/RDM control box.

Up to six power and data outputs to fi xtures or fi xture runs.Ethernet enabled option.Refer to CBX specifi cation sheet for details.

Page 9: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

9/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

Reflector 2

1ftIndirectDirect

2ft

3ft

4ft

5ft

6ft

7ft

8ft

Reflector 24

2

Reflector 11

3

Reflector 2

Reflector 2

Reflector 4

Reflector 11 2

Resolution per foot: each foot is addressed independently

SINGLE UNITS

1ft 2ft 3ft 4ft 5ft 6ft 7ft 8ft2 4 6 8 10 12 14 16WH/WH4WH/RGB 8 12 16 20 24 28 32

HCNR TCNR CCNR6

109

151220

Lit joinersSingle units

HCNR TCNR CCNR24

35

35

Lit joinersSingle units1ft to 4ft 5ft to 8ft

2 4WH/WH4WH/RGB 8

Resolution per fixture: each reflector is addressed independently

BOARD AND REFLECTOR LAYOUT PER FIXTURE LENGTH

Total number of DMX addresses required

per fixture(Direct/Indirect)

Total number of DMX addresses required

per fixture(Direct/Indirect)

6 5 4

Reflector 11 2 3

Reflector 38 7 6

Reflector 39 8 7

Reflector 311 10 9 8

Reflector 312 11 10 9

8 7 6 5

Reflector 11 2 3 4

109

Reflector 2Reflector 11 2 3 45

Reflector 41210 11

Reflector 11 2 3

Reflector 246 5

Reflector 41412 13

Reflector 11 2 3 4

Reflector 257 6

Reflector 415 1613 14

Reflector 11 2 3 4

Reflector 26 58 7

IndirectDirect

IndirectDirect

IndirectDirect

IndirectDirect

IndirectDirect

IndirectDirect

IndirectDirect

RESOLUTION DETAILSApplicable for DMX/RDM control option only.Fixture resolution can be configured on-site within the LumenID V3 software. A DMX/RDM enabled CBX is required.

Page 10: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

10/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

RESOLUTION DETAILS - continued

LIT JOINERS IN SHAPES

Reflector 1Re

flect

or 2

1 2

3

4

Reflector 11 2

Reflector 3

Refle

ctor

2

3

4

HCNRHorizontal 90°

TCNRTee 90°

CCNRCross 90°

Reflector 11 2

Reflector 3

Refle

ctor

2

3

4

Refle

ctor

4

8

7

Reflector 3

Refle

ctor

4

5

6

Reflector 5 Reflector 69

Refle

ctor

4

7

Reflector 6 Reflector 812

Refle

ctor

5

9

Refle

ctor

7

11

Direct Indirect

Direct Indirect

Direct Indirect

8

10

56

56

Page 11: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

11/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

RESOLUTION DETAILS - continued

Example: DMX addresses, resolution per foot, 8ft fixture and CCNR lit joiner

Example: DMX addresses, resolution per fixture, 8ft fixture and CCNR lit joiner

410, 11, 12

822, 23, 24

24, 5, 6

616, 17, 18

37, 8, 9

719, 20, 21

513, 14, 15

11, 2, 3

25, 26, 279

37, 38, 3913

31, 32, 3311

43, 44, 4515

28, 29, 3010

40, 41, 4214

46, 47, 4816

34, 35, 3612

8ftReflector 3 Reflector 4

Reflector 1 Reflector 2

IndirectDirect

Reflector 6 Reflector 8

Refle

ctor

5Re

flect

or 7

IndirectDirectCCNRCross 90°

CCNRCross 90°

Reflector 1 Reflector 3

Refle

ctor

2Re

flect

or 4

1028, 29, 30

925, 26, 27

1234, 35, 36

11, 2, 3

24, 5, 6

1131, 32, 33

11, 2, 3

24, 5, 6

7, 8, 93

10, 11, 124

8ftReflector 3 Reflector 4

Reflector 1 Reflector 2

IndirectDirect

Reflector 6 Reflector 8

Refle

ctor

5Re

flect

or 7

IndirectDirectReflector 1 Reflector 3

Refle

ctor

2Re

flect

or 4

11, 2, 3

34, 5, 6

21, 2, 3

410, 11, 12

13, 14, 156

16, 17, 185

37, 8, 9

719, 20, 21

822, 23, 24

RGB versionWhite light version

Page 12: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

12/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

TYPICAL WIRING DIAGRAMS

100-347V*To next fixture

100-347V* Input

To fixture

Ground greenNeutral white

Line black

Canopy

Junction box(by others)

100-347V*

100-347V*

From Dimmer or Controller

To fixture

100-347V*& Data output To next fixture

100-347V* Input

Ground greenNeutral white

Line black

Canopy

Data- orangeData+ red/purple Junction box

(by others)

Data input

Single units, daisy chain layout0-10V, DALI or EcoSystem® control options

Single units, daisy chain configurationNon-dimming or Lumentalk control options Non-dimming or Lumentalk wiring detail

0-10V, DALI or EcoSystem® wiring detail

1x DALI address per reflector.Total number of DALI addresses required per fixture:

1x EcoSystem® address per reflector.Total number of EcoSystem® addresses required per fixture:

HCNR TCNR CCNR2 3 3

Lit joinersSingle units1ft to 4ft 5ft to 8ft

2 4WH/WHHCNR TCNR CCNR

2 3 3

Lit joinersSingle units2ft to 4ft 5ft to 8ft

2 4WH/WH

*Lumentalk and RGB options not available with 347V.

WIRE COLOR / USE

GREEN GROUNDWHITE NEUTRALBLACK LINE 100-347V

ORANGEDATA +RED/ PURPLEDATA -

Maximum run lengths - 7A maximum with 10ft [3m] fixture cord

Configuration/Voltage 100V 120V 208V, 220V, 240V, 277V, 347V

47ft [14.3m]

32ft [9.8m]HO/RO

RO/RO 56ft [17.1m]

36ft [11m]

63ft [19.2m]

63ft [19.2m]

Notes: 1 Maximum run length calculations are typically based on 4ft [1.2m].Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors,refer to Board and Reflector Layout for details. Consult factory for specific applications.

Page 13: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

13/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

TYPICAL WIRING DIAGRAMS - continued

To fixture

Data- orange

Canopy

Data+ red/purple

From CBX100-347V*

& Data input

Ground greenNeutral white

Line black

Junction box(by others)

For stable DMX/RDM data signal, do not split data wires after the CBX.

100-347V*

CBX

Data input

100-347V* & Data

Single units, star layoutDMX/RDM control option DMX/RDM wiring detail

Non-dimming & Lumentalk control optionsContinuous run, single feed

Quick connectors

100-347V*

Non-dimming or Lumentalk wiring detail

100-347V*To next fixture

To next fixture

100-347V* Input

To fixture

Ground greenNeutral white

Line black

Canopy

Junction box(by others)

*Lumentalk and RGB options not available with 347V.

WIRE COLOR / USE

GREEN GROUNDWHITE NEUTRALBLACK LINE 100-347V

ORANGEDATA +RED/ PURPLEDATA -

Maximum run lengths - 7A maximum with 10ft [3m] fixture cord

Configuration/Voltage 100V 120V 208V, 220V, 240V, 277V, 347V

47ft [14.3m]

32ft [9.8m]HO/RO

RO/RO 56ft [17.1m]

36ft [11m]

63ft [19.2m]

63ft [19.2m]

Notes: 1 Maximum run length calculations are typically based on 4ft [1.2m].Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors,refer to Board and Reflector Layout for details. Consult factory for specific applications.

Page 14: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

SHAPES

EM - R23

14/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

TYPICAL WIRING DIAGRAMS - continued

Continuous run, multiple feeds

DMX/RDM control option*Continuous run, single feed

Circuit #1100-347V*

Data input

100-347V*& Data input

100-347V* & Data input

Circuit #2100-347V*

Data

CBXCBX

For stable DMX/RDM data signal,do not split data wires after the CBX.

For stable DMX/RDM data signal,do not split data wires after the CBX.

Quick connectors

100-347V*& Data

To fixture

Data- orange

Canopy

Data+ red/purple

From CBX100-347V*

& Data intput

Ground greenNeutral white

Line black

Junction box(by others)

DMX/RDM wiring detail

100-347V* CBXData input

0-10V, DALI or or EcoSystem® control optionsContinuous run, single feed

Quick connectors

100-347V*Data input

From Controller

To fixture

100-347V*& Data output To next fixture

100-347V*Input

Ground greenNeutral white

Line black

Canopy

Data- orangeData+ red/purple Junction box

(by others)

0-10V, DALI or EcoSystem® wiring detail

1x DALI address per reflector.Total number of DALI addresses required per fixture:

1x EcoSystem® address per reflector.Total number of EcoSystem® addresses required per fixture:

HCNR TCNR CCNR2 3 3

Lit joinersSingle units1ft to 4ft 5ft to 8ft

2 4WH/WHHCNR TCNR CCNR

2 3 3

Lit joinersSingle units2ft to 4ft 5ft to 8ft

2 4WH/WH

*Lumentalk and RGB options not available with 347V.

Page 15: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

EM - R23

15/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

PENDANTDIRECT/INDIRECT LIGHTING

SINGLE UNITSCONTINUOUS RUNS

HOW TO ORDER - SINGLE UNITS AND CONTINUOUS RUNS

1 Housing:

LLI2P - Lumenline™ Pendant 2" wide

2 Light Direction:

DI - Direct/Indirect lighting

3 Voltage:100 - 100 volts120 - 120 volts208 - 208 volts220 - 220 volts

240 - 240 volts277 - 277 volts347 - 347 volts1

4 Length:SU1 - Single Unit 12 1/2 inches (317mm)SU2 - Single Unit 24 1/4 inches (616mm)SU3 - Single Unit 36 1/16 inches (916mm)SU4 - Single Unit 47 7/8 inches (1216mm) SU5 - Single Unit 59 3/4 inches (1518mm)SU6 - Single Unit 71 9/16 inches (1818mm)SU7 - Single Unit 83 3/8 inches (2119mm)SU8 - Single Unit 95 1/4 inches (2419mm)C__ - Continuous run, specify in 1’ increments.

5 Direct Lighting:

Output & Color temperature:dRO 27K - 2700K regular output 6W/ftdRO 30K - 3000K regular output 6W/ftdRO 35K - 3500K regular output 6W/ftdRO 40K - 4000K regular output 6W/ftdHO 27K - 2700K high output 12W/ft2

dHO 30K - 3000K high output 12W/ft2

dHO 35K - 3500K high output 12W/ft2

dHO 40K - 4000K high output 12W/ft2

dRO RGB - Tri-color red, green and blue direct lighting 6W/ft3

Optics:WFL - Wide flood, 100° distribution, frosted lens NF - Narrow flood, 30° x 60° distribution, highly reflective white painted 

louver4

WW - True asymmetric wallwash, highly reflective white painted louver4

6 Indirect Lighting:

Output & Color temperature:iRO 27K - 2700K regular output 6W/ftiRO 30K - 3000K regular output 6W/ftiRO 35K - 3500K regular output 6W/ftiRO 40K - 4000K regular output 6W/ftiHO 27K - 2700K high output 12W/ft2

iHO 30K - 3000K high output 12W/ft2

iHO 35K - 3500K high output 12W/ft2

iHO 40K - 4000K high output 12W/ft2

iRO RGB - Tri-color red, green and blue indirect lighting 6W/ft3

Optics:WFL - Wide flood, 100° distribution, clear lensBWW - Batwing wide, 170° distribution

7 Control:NO - On/Off controlLT - Lumentalk5

DIM - 0-10V Dimming option6

DMX/RDM - DMX/RDM enabled7

DALI - DALI Dimming option8

ES - Lutron® EcoSystem® Enabled Dimming9

8 Mounting:ACC50 - Aircraft cable, 50" (field adjustable)ACC100 - Aircraft cable, 100" (field adjustable)ACC250 - Aircraft cable, 250" (field adjustable)

9 Finish:BK - Black Sandtex10

SI - Silver Sandtex10

WH - Smooth white10

CC - Custom color and finish (please specify RAL color)11

10 Option:BLL - Black painted louver12

SSL - Semi-specular louver12

Photometric performance will vary with black and semi-specular louveroptions, see Photometric Information pages for more information.

LLI2P DI 1 2 3 4 5 6 7 8 9 10

Notes:1 347V is not available for 1' [305mm] lengths. 347V is not available for RGB color option or LT control option. 2 High output direct lighting cannot be combined with high output indirect lighting. 3 RGB optionrequires DMX/RDM control to be specified in Control section. 4 Not available for RGB color option. 5 1% minimum dimming value. Available with white light only, not available for 1' [305mm] lengths.6 10% minimum dimming value. 7 1% minimum dimming value. Fixtures set to by fixture resolution (consult the Resolution Details pages for the number of DMX addresses per fixture length and type).8 1% minimum dimming value. Available with white light only. Consult Typical Wiring Diagram pages for the number of DALI addresses per fixture length and type. 9 1% minimum dimming value. Available withwhite light only, not available for 1' [305mm] lengths. Consult Typical Wiring Diagram pages for the number of EcoSystem® addresses per fixture length and type. 10 Standard white finish for cable and canopy,consult -factory for other options. 11 North American RAL colors specified with RAL number only are provided with a smooth/high-gloss finish. Please consult factory for other RAL textures and glosses, or tomatch alternate color charts. Final color matching results may vary.12 Available for WW and NF optics, not compatible with WFL option. 

Page 16: Specification Sheet lumenline 2 - Lumenpulseappv1.lumenpulse.com/_files/products/files/363_en_lumenpulse_lumen...Specification Sheet lumenline 2 ... Direct ide flood Direct true asymmetric

EM - R23

16/16

2016.07.28

Specification Sheet lumenline™ 2

5-year limited warranty.

Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.

© Copyright Lumenpulse 2016

1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6

1.877.937.3003 P.514.937.3003 F. [email protected]

Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.

PENDANTDIRECT/INDIRECT LIGHTING

SHAPESHOW TO ORDER - SHAPES

1 Housing:

LLI2P - Lumenline™ Pendant 2" wide

2 Light Direction:

DI - Direct/Indirect lighting

3 Voltage:100 - 100 volts120 - 120 volts208 - 208 volts220 - 220 volts

240 - 240 volts277 - 277 volts347 - 347 volts1

4 Length:IMPORTANT: Side length up to 20’ as a standard. Consult factory for any other shape requirements.

S__ - Square shape: specify side length (equal sides) R__x__ - Rectangular shape: specify longer side x shorter sideL__ - ”L” shape: specify side length (equal sides)T__ - ”T” shape: specify side length (equal sides) X__ - Cross shape: specify side length (equal sides)

5 Joiner Type:LJ - Lit joiner, 17 inches nominal side length moduleUJ - Unlit joiner, 2 11/16 inches (68mm) module (0.77kg/1.7 lbs) 

6 Direct Lighting:

Output & Color temperature:dRO 27K - 2700K regular output 6W/ftdRO 30K - 3000K regular output 6W/ftdRO 35K - 3500K regular output 6W/ftdRO 40K - 4000K regular output 6W/ftdHO 27K - 2700K high output 12W/ft2 dHO 30K - 3000K high output 12W/ft2

dHO 35K - 3500K high output 12W/ft2

dHO 40K - 4000K high output 12W/ft2

dRO RGB - Tri-color red, green and blue direct lighting 6W/ft3

Optics:NF and WW optics not available for shapes with lit joiner.

WFL - Wide flood, 100° distribution, frosted lens NF - Narrow flood, 30° x 60° distribution, highly reflective white painted 

louver4

WW - True asymmetric wallwash, highly reflective white painted louver4

7 Indirect Lighting:

Output & Color temperature:iRO 27K - 2700K regular output 6W/ftiRO 30K - 3000K regular output 6W/ftiRO 35K - 3500K regular output 6W/ftiRO 40K - 4000K regular output 6W/ftiHO 27K - 2700K high output 12W/ft2

iHO 30K - 3000K high output 12W/ft2

iHO 35K - 3500K high output 12W/ft2

iHO 40K - 4000K high output 12W/ft2

iRO RGB - Tri-color red, green and blue indirect lighting 6W/ft3

Optics:WFL - Wide flood, 100° distribution, clear lensBWW - Batwing wide, 170° distribution

8 Control:NO - On/off controlLT - Lumentalk5

DIM - 0-10V dimming option6

DMX/RDM - DMX/RDM enabled7

DALI - DALI dimming option8

ES - Lutron® EcoSystem® Enabled dimming9

9 Mounting:ACC50 - Aircraft cable, 50" (field adjustable)ACC100 - Aircraft cable, 100" (field adjustable)ACC250 - Aircraft cable, 250" (field adjustable)

10 Finish:BK - Black Sandtex10

SI - Silver Sandtex10

WH - Smooth white10

CC - Custom color and finish (please specify RAL color)11

11 Option:BLL - Black painted louver12

SSL - Semi-specular louver12

Photometric performance will vary with black and semi-specular louveroptions, see Photometric Information pages for more information.

LLI2P DI 1 2 3 4 5 6 7 8 9 10 11

Notes:1 347V is not available for 1' [305mm] lengths. 347V is not available for RGB color option or LT control option. 2 High output direct lighting cannot be combined with high output indirect lighting. 3 RGB optionrequires DMX/RDM control to be specified in Control section. 4 Not available for RGB color option and lit joiners. 5 1% minimum dimming value. Available with white light only, not available for 1' [305mm]lengths. 6 10% minimum dimming value. 7 1% minimum dimming value. Fixtures set to by fixture resolution (consult the Resolution Details pages for the number of DMX addresses per fixture length and type).8 1% minimum dimming value. Available with white light only. Consult Typical Wiring Diagram pages for the number of DALI addresses per fixture length and type. 9 1% minimum dimming value. Available withwhite light only, not available for 1' [305mm] lengths. Consult Typical Wiring Diagram pages for the number of EcoSystem® addresses per fixture length and type. 10 Standard white finish for cable and canopy,consult factory for other options. 11 North American RAL colors specified with RAL number only are provided with a smooth/high-gloss finish. Please consult factory for other RAL textures and glosses, or tomatch alternate color charts. Final color matching results may vary. 12 Available for WW and NF optics, not compatible with WFL option.