3
© 2014 Elkay SPEC00091 (06/2014) PRODUCT SPECIFICATION High-efficiency electric, refrigerated water cooler. Model LZSTLG8 shall deliver 8 GPH of 50°F drinking water at 90°F ambient and 80°F inlet water. Unit shall meet ADA guidelines. Shall Include the WaterSentry ® VII 1500-gallon capacity filter, certified to NSF/ANSI 42 and 53. Unit shall be lead-free design which is certified to NSF/ANSI 61 and 372 and meets Federal and State low-lead requirements. Unit shall be certified to UL399 and CAN/CSA 22.2 No. 120. Unit shall be GreenSpec ® Listed. STANDARD FEATURES Energy efficiency performance exceeds average market performance by 35% per CSA 815-99 • WaterSentry ® VII 1500-gallon capacity Filtration System, certified to NSF/ANSI 42 & 53 (Lead, Class 1 Particulate, Chlorine, Taste & Odor) Easy-Touch front and side pushbar controls • Flexi-Guard ® StreamSaver water conservation bubbler *Versatile cooler design allows units to be installed either left-hand high and right-hand low or left-low and right high Cooler panel finishes: Light Gray Granite Vinyl Clad Steel or Stainless Steel Rated for Indoor Use COOLING SYSTEM High-efficiency Compressor: Hermetically-sealed, reciprocating type, single phase. Sealed-in lifetime lubrication. Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated. Cooling Unit: Combination tube-tank type. Self-cleansing. Continuous copper tubing with stainless steel tank. Fully insulated with EPS foam which meets UL requirements for self-extinguishing material. Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated capillary tube. Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements. CAPACITIES CHART Model Voltage / Hertz Chilling** Capacity F.L. Amps Rated Watts Approx. Ship Wt. UL399 and CAN/ CSA 22.2 No. 120 Certified ADA COMPLIANT ANSI/NSF 61 and 372 Certified ANSI/NSF 42 and 53 Certified (Filter only) GreenSpec ® Listed LZSTLG8S*C 115V / 60Hz 8 GPH 3.2 360 75 lbs *Color code of (L) Light Gray Granite or (S) Stainless Steel cooler panels. **Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water. RATED FOR INDOOR USE ONLY SPECIFICATIONS High-Efficiency GreenSpec ® Listed Versatile Bi-Level Filtered Water Cooler Model LZSTLG8 CONSTRUCTION Stainless Steel basin with integral drain Galvanized structural steel cooler chassis provides structural integrity Cooler cabinet available as Light Gray Granite Vinyl Clad Steel or Stainless Steel (additional cost) construction • Flexi-Guard ® StreamSaver Safety Bubbler utilizes an infused anti-microbial pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact. Lower-flow water efficient water stream. REPLACEMENT FILTER: 51299C (single) Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical components and water system are warranted for 12 months from date of installation or 18 months from factory shipment, whichever date falls first. This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producer’s offerings, be certain these features are not overlooked. 2222 Camden Court Oak Brook, IL 60523 630-572-3192 elkay.com In keeping with our policy of continuing product improvement, Elkay reserves the right to change specification without notice. Please visit elkay.com for the most current version. *Versatile cooler configuration as shipped *Versatile cooler configuration alternate installation COMMERCIAL RESTROOM ACCESSORIES WWW.RESTROOMDIRECT.COM 7049372673 129 Oak Park Dr., Unit A, Mooresville, NC 28115 Distributed By

Upload: others

Post on 11-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SPECIFICATIONS Model LZSTLG8 · 2016. 10. 24. · PRODUCT SPECIFICATION. High-efficiency electric, refrigerated water cooler. Model LZSTLG8 . shall deliver 8 GPH of 50°F drinking

© 2014 ElkaySPEC00091 (06/2014)

PRODUCT SPECIFICATIONHigh-efficiency electric, refrigerated water cooler. Model LZSTLG8 shall deliver 8 GPH of 50°F drinking water at 90°F ambient and 80°Finlet water. Unit shall meet ADA guidelines. Shall Include the WaterSentry® VII 1500-gallon capacity filter, certified to NSF/ANSI 42 and 53. Unit shall be lead-free design which is certified to NSF/ANSI 61 and 372 and meets Federal and State low-lead requirements. Unit shall be certified to UL399 and CAN/CSA 22.2 No. 120. Unit shall be GreenSpec® Listed.

STANDARD FEATURES• Energy efficiency performance exceeds average market

performance by 35% per CSA 815-99• WaterSentry® VII 1500-gallon capacity Filtration System, certified

to NSF/ANSI 42 & 53 (Lead, Class 1 Particulate, Chlorine,Taste & Odor)

• Easy-Touch front and side pushbar controls• Flexi-Guard® StreamSaver™ water conservation bubbler• *Versatile cooler design allows units to be installed either

left-hand high and right-hand low or left-low and right high• Cooler panel finishes: Light Gray Granite Vinyl Clad Steel or

Stainless Steel• Rated for Indoor UseCOOLING SYSTEM• High-efficiency Compressor: Hermetically-sealed, reciprocating

type, single phase. Sealed-in lifetime lubrication.• Condenser: Fan cooled, copper tube with aluminum fins. Fan

motor is permanently lubricated.• Cooling Unit: Combination tube-tank type. Self-cleansing.

Continuous copper tubing with stainless steel tank. Fullyinsulated with EPS foam which meets UL requirements forself-extinguishing material.

• Refrigerant Control: Refrigerant R134a is controlled byaccurately calibrated capillary tube.

• Temperature Control: Easily accessible enclosed adjustablethermostat is factory preset. Requires no adjustment other thanfor altitude requirements.

CAPACITIES CHART

Model Voltage / Hertz

Chilling**Capacity

F.L.Amps

Rated Watts

Approx.ShipWt.

UL399 and CAN/

CSA 22.2 No. 120 Certified

ADA COMPLIANT

ANSI/NSF 61 and 372 Certified

ANSI/NSF 42 and 53 Certified

(Filter only)

GreenSpec® Listed

LZSTLG8S*C 115V / 60Hz 8 GPH 3.2 360 75 lbs • • • • •

*Color code of (L) Light Gray Granite or (S) Stainless Steel cooler panels.**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.

RATED FOR INDOOR USE ONLY

SPECIFICATIONS

High-Efficiency GreenSpec® Listed Versatile Bi-Level Filtered Water Cooler

Model LZSTLG8

CONSTRUCTION• Stainless Steel basin with integral drain• Galvanized structural steel cooler chassis provides

structural integrity• Cooler cabinet available as Light Gray Granite Vinyl

Clad Steel or Stainless Steel (additional cost)construction

• Flexi-Guard® StreamSaver Safety Bubbler utilizes aninfused anti-microbial pliable polyester elastomer toprevent accidental mouth injuries. Flexes on impact.Lower-flow water efficient water stream.

REPLACEMENT FILTER:• 51299C (single)

Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical components andwater system are warranted for 12 months from dateof installation or 18 months from factory shipment, whichever date falls first.

This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producer’s offerings, be certain these features are not overlooked.

2222 Camden CourtOak Brook, IL 60523

630-572-3192elkay.com

In keeping with our policy of continuing product improvement, Elkay reserves the right to change specification without notice. Please visit elkay.com for the most current version.

*Versatile cooler configurationas shipped

*Versatile cooler configurationalternate installation

COMMERCIAL RESTROOM ACCESSORIES WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oak Park Dr., Unit A, Mooresville, NC 28115

Dis

trib

uted

By

Page 2: SPECIFICATIONS Model LZSTLG8 · 2016. 10. 24. · PRODUCT SPECIFICATION. High-efficiency electric, refrigerated water cooler. Model LZSTLG8 . shall deliver 8 GPH of 50°F drinking

19"483mm

21 7/8"556mm

24 1/2"622mm

34 5/16"872mm

2"51mm

28 13/16"732mm

2"51mm

18 3/8"467mm

6 3/8"162mm

6 3/8"162mm

2"51mm

7"178mm

7"178mm

2"51mm

3 7/8"98mm

B

A(ALT. LOCATION)

F

F

18 3/8"467mm

9/32"7mm DIA. ((12)

E

E

6 3/8"162mm

6 3/8"162mm

DPREFFEREDLOCATION

19 7/16"494mm

13 15/16"354mm

7/8"22mm

22 15/16"583mm

5 3/4"146mm

17 7/16"443mm

FINISHED FLOOR

‰ ‰

APREFFEREDLOCATION

1 7/16"37mm

3"76mm

12 1/2"318mm

C

8 1/16"205mm

27"686mm

ADAREQUIREMENT

31 5/16"796mm

RIMHEIGHT

32 7/8"835mmORIFICEHEIGHT

36 13/16"936mm

RIMHEIGHT

38 3/8"975mmORIFICEHEIGHT

19"483mm

HANGERBRACKET

FILTER

FILTER

REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER

LEGEND:A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain. Drain stub 2” (51mm) out from wall.C = 1-1/2” Trap (not furnished).D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall.F = 7/16” (11mm) Bolt Holes for fastening to wall.NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)

RATED FOR INDOOR USE ONLYNOTICEThis water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.

IMPORTANT! INSTALLER PLEASE NOTE:These units are designed and built to provide water to the user which has not been altered by materials in the cooler waterway. The grounding of electrical equipment such as telephone, computers, etc. to water lines is a commonprocedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water coolercreating an electrolysis which results in a metallic taste or an increase in the metal content of the water. This condition is avoidable by installing the coolerusing the proper materials as shown.

ROUGH-IN DIMENSIONS

High-Efficiency GreenSpec® Listed Versatile Bi-Level Filtered Water CoolerModel LZSTLG8

Printed in U.S.A.© 2014 ElkayPage 2

2222 Camden CourtOak Brook, IL 60523

630-572-3192elkay.com

ROUGH-IN FOR LEFT-HAND HIGH SIDE MODELS

Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes:

COMMERCIAL RESTROOM ACCESSORIES WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oak Park Dr., Unit A, Mooresville, NC 28115

Dis

trib

uted

By

Page 3: SPECIFICATIONS Model LZSTLG8 · 2016. 10. 24. · PRODUCT SPECIFICATION. High-efficiency electric, refrigerated water cooler. Model LZSTLG8 . shall deliver 8 GPH of 50°F drinking

19 7/16"494mm

24 1/2"622mm

19"483mm

28 13/16"732mm

2"51mm

2"51mm

18 3/8"467mm

6 3/8"162mm

6 3/8"162mm

6 3/8"162mm

6 3/8"162mm

2"51mm

2"51mm

18 3/8"467mm

O9/32"7mm (12)

E

13 15/16"354mm

21 7/8"556mm

AREFERREDLOCATION

DALT. LOCATION

3 7/8"98mm

7"178mm

7"178mm

B

FF

DPREFFEREDLOCATION

A(ALT. LOCATION)

E

7/8"22mm

FINISHED FLOOR

‰ ‰

22 15/16"583mm

5 3/4"146mm

34 5/16"872mm

1 7/16"37mm

3"76mm

12 1/2"318mm

C

8 1/16"205mm

27"686mm

ADAREQUIREMENT

31 5/16"796mm

RIMHEIGHT

32 7/8"835mmORIFICEHEIGHT

36 13/16"936mm

RIMHEIGHT

38 3/8"975mmORIFICEHEIGHT

HANGERBRACKET

19"483mm

FILTERFILTER

LEGEND:A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain. Drain stub 2” (51mm) out from wall.C = 1-1/2” Trap (not furnished).D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall.F = 7/16” (11mm) Bolt Holes for fastening to wall.NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)

RATED FOR INDOOR USE ONLY

NOTICEThis water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.

IMPORTANT! INSTALLER PLEASE NOTE:These units are designed and built to provide water to the user which has not been altered by materials in the cooler waterway. The grounding of electrical equipment such as telephone, computers, etc. to water lines is a commonprocedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water coolercreating an electrolysis which results in a metallic taste or an increase in the metal content of the water. This condition is avoidable by installing the coolerusing the proper materials as shown.

High-Efficiency GreenSpec® Listed Versatile Bi-Level Filtered Water CoolerModel LZSTLG8

REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER

ROUGH-IN DIMENSIONS

Printed in U.S.A.© 2014 ElkayPage 3

2222 Camden CourtOak Brook, IL 60523

630-572-3192elkay.com

ROUGH-IN FOR RIGHT-HAND HIGH SIDE MODELS

Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes:

COMMERCIAL RESTROOM ACCESSORIES WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oak Park Dr., Unit A, Mooresville, NC 28115

Dis

trib

uted

By