F LAME Soil Plant General Analyzer PHOTOMETER SPECTRO Many of soil testing laboratories these days face increasing demands from the farmers for rapid feedback of soil test result. Our company has been focused to provide the optimum equipment for simplified nutrient extraction and colorimetry method with preliminary installed calibration curves. SFP series 13 was developped under SPAD project ※2 from 1981. Now we launch 4th generation, SFP-4i, which realized to increase target elements for soil, and it also optionally inlcudes new category - potting soil, in addition to conventional testing categories. Safety function is drastically improved, too. We believe that SFP-4i, which makes clear disinction from general laboratory equipment, will be intelligently, integrally, improvingly and internationally good help to the soil and plant laboratories. SFP series is used in research laboratories, agricultural extension centers, city / town halls, universities, private enterprise, agricultural cooperatives, compost centers, etc. In latest years, it is exported to Asian countries, too. ※1 SFP stands for Spectro-Flame-Photometer. It is a combination of spectrophotometer and flame photometer. ※2 SPAD R is an abbrebiation for Soil&Plant Analyzer Development Project under Ministry of Agriculture, Forestry and Fisheries in Japan. History of SFP series ※1 SFP-1 SFP-2 SFP-3 SFP-4i Direct reading for K2O,CaO,MgO,P2O5,B,NO3-N Enhanced parameters (Soil 17, Plant 6elements) Adopted digital circuit Enhanced category of analysis for compost & hydro culture solution Enhanced category for potting soil, Increased safety for flame control Increased data storage From Dec. 1983 From June 1986 From Feb. 1999 From Aug. 2012 SPECTRO-FLAME-PHOTOMETER ― To more simply, rapidly and effectively manage the soil & plant analysis― What is ?

Upload: others

Post on 19-Jul-2020

49 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PHOTOMETERSPECTRO-FLAME-PHOTOMETER SPECTRO-FLAME-PHOTOMETER Specifications Model SFP-4i SFP-4i UV※ by diffraction grating 250~900nm (UV visible) Xenon flash lamp (for UV visible

FLAME

Soil Plant General Analyzer

PHOTOMETER

SPECTRO

Many of soil testing laboratories these days face increasing demands from the farmers for rapid feedback of soil test result. Our company has been focused to provide the optimum equipment for simplified nutrient extraction and colorimetry method with preliminary installed calibration curves. SFP series 1̃3 was developped under SPAD project ※2 from 1981. Now we launch 4th generation, SFP-4i, which realized to increase target elements for soil, and it also optionally inlcudes new category - potting soil, in addition to conventional testing categories. Safety function is drastically improved, too. We believe that SFP-4i, which makes clear disinction from general laboratory equipment, will be intelligently, integrally, improvingly and internationally good help to the soil and plant laboratories.

SFP series is used in research laboratories, agricultural extension centers, city / town halls, universities, private enterprise,agricultural cooperatives, compost centers, etc. In latest years, it is exported to Asian countries, too.

※1 SFP stands for Spectro-Flame-Photometer. It is a combination of spectrophotometer and flame photometer.※2 SPAD R is an abbrebiation for Soil&Plant Analyzer Development Project under Ministry of Agriculture, Forestry and Fisheries in Japan.

History of SFP series

※1

SFP-1 SFP-2 SFP-3 SFP-4i

Direct reading for K2O,CaO,MgO,P2O5,B,NO3-N

Enhanced parameters (Soil 17, Plant 6elements) Adopted digital circuit

Enhanced category of analysis for compost & hydro culture solution

   Enhanced category for potting soil, Increased safety for flame control Increased data storage

From Dec. 1983 From June 1986 From Feb. 1999 From Aug. 2012

SPECTRO-FLAME-PHOTOMETER

― To more simply, rapidly and effectively     manage the soil & plant analysis―

What is ?

Page 2: PHOTOMETERSPECTRO-FLAME-PHOTOMETER SPECTRO-FLAME-PHOTOMETER Specifications Model SFP-4i SFP-4i UV※ by diffraction grating 250~900nm (UV visible) Xenon flash lamp (for UV visible

SPECTRO-FLAME-PHOTOMETERSPECTRO-FLAME-PHOTOMETER

Simple, Rapid & Accurate

Caliblation curves are preliminary installed in main unit   Exclusive reagents, produced by our company, helps to make simple and rapid analysis.   Sensitive colorimetric method is developped by our proprietary technique, which made possible to analyze without atomic absorption spectroscopy.

▲▲

Increased safety    Gas leak detection, auto-ignition, flame-failure detection, auto-extinguish function at the time of earthquake

Exclusive testing tools & reagents for SFP-4i is separately available.Please contact us or our distributors for details.

User - friendly operation panel   7.5inch color LCD touch panel

Enhanced volume for data storage & ID registration   Maximum 2,000 data storage in main unit, USB (approx. 65,000data in USB memory with more than 128MB)

   Depends on the element , possible to select eighter UV or visible spectrophotometer (This function available optionally only with SFP-4i UV)

Operation screen Without ID

With ID

Manifold of flame photometer

Auto-ignition, detection of flame failure

Page 3: PHOTOMETERSPECTRO-FLAME-PHOTOMETER SPECTRO-FLAME-PHOTOMETER Specifications Model SFP-4i SFP-4i UV※ by diffraction grating 250~900nm (UV visible) Xenon flash lamp (for UV visible

SPECTRO-FLAME-PHOTOMETERSPECTRO-FLAME-PHOTOMETER

Relation with SFP and conventional method Parameter

Procedure of anaysis (Soil, example of CaO)

Flow of analysis

Flow on screen

Extract Color Measure Result

Semi-micro Shollenberger methodor alternative method H7.0・1N ammonium acetate  Ratio 1:20

Color reagent 5mLBlank reagent 0.2mLExtracted, filtered sample 0.2mL

SOIL mode / wavelength 540mmAbsorb blank & sample solution

Concentration(mg/100g)

Measurement mode, test element selection

Measurement screen Output

Print out ,USB storageor output to PC

▲ ▲ ▲

▲ ▲

①Soil, MgONote:

Sample taken from typical volcanic ash soil and non-volcanin ash soil in Japan.

②Plant, KNote: Sample was taken from vegetable leaves such as cabbage, lettuce, spinach,radish, cucumber, strawberry, and fruits leaves such as mandarin, apple, peach,persimmon, and rice (leaves and ears), tea, mum, etc.

③Compost, CaONote: Livestock waste is used as sample.

C a t e g o r y

S o i l

P l a n t

F r e e

C a t e g o r y

P o t t i n g s o i l

C om p o s t

H y d r o p o n i c

c u l t u r e

s o l u t i o n

※1 Optional Na filter is necessary.※2 Available only with SFP-4iUV

E l e m e n t s M e t h o d o f a n a l y s i s Measuring range0-150 mg/100g 0-1500 mg/100g 0-200 mg/100g 0-100 mg/100g 0-75.0 mg/100g 0-600 mg/100g 0-150.0mg/100g 0-300.0mg/100g 0-44.6 me/100g

0-2686 0-12.0 %

0-35.0 mg/100g 0-70.0 mg/100g 0-100.0 mg/100g 0-85.6 mg/100g

0-6.00 % 0-100.0 mg/kg 0-6.00 mg/kg 0-1.000 %

0-15 mg/100g 0-12.8 mg/100g 0-25.0 mg/100g 0-40.0mg/L ―0-10.00 % 0-5.00 % 0-1.80 % 0-1.05 % 0-5.00 %

0-25.0 mg/100g 0-5000 mg/kg 0-250.0 mg/kg 0-150 mg/kg ―――

Measuring range 0-150mg/100mL 0-1500mg/100mL 0-200mg/100mL 0-300mg/100mL 0-25.0mg/100mL 0-50.0mg/100mL 0-44.6me/100mL

0-10.0% 0-35.0% 0-4.0% 0-2.0% 0-12.0%

0-625mg/100g 0-500mg/100g

0-10.0% 0-400mg/L 0-500mg/L 0-90.0mg/L 0-20mg/L 0-65.4mg/L 0-62.5mg/L 0-250mg/L 0-13.4mg/L 0-40mg/L

Flame photometryOCPCXB-1Flame photometryMurphy-RileyMurphy-RileyBanado molybdenum acidBanado molybdenum acidIndo phenolBanado molybdenum acidKumada methodIndo phenolAlkali reduction / diazo pigmentsAscorbic acid reduction / molybdenum blueAscorbic acid reduction / molybdenum blueΟ-Phenanthroline Sodium periodate oxidization Azomethine HIndo phenolSodium periodate oxidization Ascorbic acid reduction / molybdenum blueIndo phenolUV photometry ※2Colorimetry / Flame photometryFlame photometryOCPCXB-1Murphy-RileyIndo phenolIndo phenolAlkali diazo pigmentsSodium periodate oxidization Azomethine HColorimetry / Flame photometrySpectro / FlameSpectro / Flame

Me t h o d o f a n a l y s i sFlame photometryOCPCXB-1Murphy-RileyIndo phenolAlkali reduction / diazo pigmentsIndo phenolFlame photometryOCPCXB-1Flame photometryMurphy-RileyIndo phenolAlkali reduction / diazo pigments HCl extraction Indo phenolFlame photometryOCPCXB-1Flame photometryMurphy-Riley 法Indo phenolAlkali reduction / diazo pigmentsΟ- phenanthroline Ascorbic acid reduction / molybdenum blue

K2O(1:20)CaO(1:20)MgO(1:20)Na2O(1:20)※1Tr-P2O5(Low)Tr-P2O5(High)Bray P2O5(1:10)Bray P2O5(1:20)CEC (1:10、1:20)P-abcHumusNH4-NNO3-NAS-SiO2PB-SiO2Fe2O3MnBT-N

WS-SiO2Av-N (Upland soil)

Solb-N

FreeKCaMgT-PT-NNH4-NNO3-NMnBFreeAbsorptionIntensity

E l em e n t sK2OCaOMgOW-P2O5 NH4-NNO3-NCECK2OCaOMgONa2O ※1P2O5NH4-NNO3-NOrg-NT-NKCaMgNa ※1PNH4-NNO3-NFeSi

Please ask for details

Option

Conventional method (mg/100g)

Conventional method (%)

Conventional method (%)

SFP, H

Cl extraction (%

)

Page 4: PHOTOMETERSPECTRO-FLAME-PHOTOMETER SPECTRO-FLAME-PHOTOMETER Specifications Model SFP-4i SFP-4i UV※ by diffraction grating 250~900nm (UV visible) Xenon flash lamp (for UV visible

SPECTRO-FLAME-PHOTOMETERSPECTRO-FLAME-PHOTOMETER

SpecificationsMo d e l S F P - 4 i S F P - 4 i U V※

by diffraction grating250 ~ 900nm (UV visible)Xenon flash lamp (for UV visible )

Silicon photo diodeFlow cellApprox. 2.5mL(Sample viscosity :like pure water, time to absorb :5sec.)230×400×305mm (W×D×H)

Approx. 13kg

【Spectro】MethodWavelength range

Light source

Detector

Measuring cellSample volume

Dimensions

Weight

【Flame】

Burning methodBurning gasAuxiliary gas

WavelengthSample volume DimensionsWeight 【Controller】

【Utility】

Display

Memory storage

Printer

External output

Dimensions

Weight

Power source・Exclusive tools for analysis & reagents are separately available.・ Air compressor & gas regulation valve is required separately.・Please prepare the propane gas and gas cylinder.

Power consumption

※UV type is an optional model

AC100 ~ 240V 50/60HzApprox. 300VA

by diffraction grating390 ~ 900nm (Visible)

Halogen lamp (Visible)

Silicon photo diode

Flow cellApprox. 2.5mL(Sample viscosity:like pure ware, time to absorb:5sec.)

230×400×305mm (W×D×H)

Approx. 13kg

 Premix type burnerPopane gasAir

Interferrence filter (768nm)Approx. 2.5mL(viscosity : such as pure water. Time to wait for flame stability :8 sec.)

260×290×535mm (W×D×H)

Approx.13kg

7.5 inch LCD color touch panel Memory in main unit:up to 2,000 data

USBmemory:approx. 165,000 data with 128MB Width 58mm Thermal printer

USB:1port (Exclusive for USB memory)LAN:1port

RS-232C:1port ( For external connection with PC)

230×400×170mm (W×D×H)

Approx. 4.5kg

● Our company provides layout plan of soil laboratory with SFP-4i upon request. Please contact us for the details. ● The specifications are subject to change without prior notice.

For details of this product, please contact us or our distributors

URL http://www.fujihira.co.jp/

Related products

Automatic sample changer (ASC-60-SFP)Exclusive for SFP-4iAutomatic sample changing up to 60 samples for your work efficiency.

Dimensions ・・・380(W)×560(D)×400(H)mmWeight ・・・Approx.15kgPower consumption ・・・AC100 ~ 240V 50/60Hz Approx. 30VA

Capacity ・・・60samples

▲▲

Automatic soil crusherand sieve, SSM-1Dried soil is crushed by hexagonal rollersand sieve it automatically.

Horizontal shakerSHM-1Supplied with exclusive shaking bottles.Capacity 50 bottlesTimer count down function provided.Completion buzzer is provided up to 8 different sound for easier recognition at the time of using pleural unit at once.

pH meter HM-25R/30RUp to 300 data storage provided.RS-232/ External printer connection

EC meter CM-25R/30RUp to 300 data storage provided.RS-232/External printer connection

Soil data management program (SDB)Data from different analytical equipment can bemanaged in one software

Rapid soil CEC determinationappratus

Within 1hour, CEC extraction for 10 samples is possible.

Fujihira Industry Co., Ltd.6-11-6 Hongo Bunkyo-ku Tokyo 113-0033 Japan

Tel: +81-3-3812-2270 Fax: +81-3-3812-3663

Tools for field test

Dr.SoilFor pH and 9 elements.9 elements can be extracted at once !Color forming is simplified, too, as muchas possible.

Dr.CompoFor compost maturity check on the spot bycomparing with enclosed color chart.