spectro's clean room services the proven choice for … · 2019-12-28 · air velocities...

4
SPECTRO's CLEAN ROOM SERVICES The Proven Choice for Critical Environment Conditions SPECTRO's CLEAN ROOM SERVICES The Proven Choice for Critical Environment Conditions Integrity Reliability Performance Cleanrooms Datacenters Manufacturing

Upload: others

Post on 11-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SPECTRO's CLEAN ROOM SERVICES The Proven Choice for … · 2019-12-28 · air velocities (90+/-20 FPM or 0.45 m/s to 0.50m/s ) as per the International Standards. The average airlow

SPECTRO's

CLEAN ROOM SERVICES

The Proven Choice for

Critical Environment Conditions

SPECTRO's

CLEAN ROOM SERVICES

The Proven Choice for

Critical Environment Conditions

Integrity Reliability Performance

Cleanrooms Datacenters Manufacturing

Page 2: SPECTRO's CLEAN ROOM SERVICES The Proven Choice for … · 2019-12-28 · air velocities (90+/-20 FPM or 0.45 m/s to 0.50m/s ) as per the International Standards. The average airlow

OUR KEY SERVICES

Particle Count Test

www.spectrogroup.com

We are Having ATI Aerosol Photometer and AerosolGenerator to test the Integrity of HEPA �ilter in CleanRooms.AllHEPA/ULPAintegritytestsperformedbyusareexecuted in accordance with IES-RP-CC-001-86 & ISO14644.WeareequippedtoperformDOP/PAOHEPAFilterIntegrityTestwithbothDi–OctalPhthalate(DOP)andPolyAlphaOle�in(PAO)dependingonclient-facility'sspeci�icrequirement.

HEPA/ULPA Filter Integrity Test

Air Velocity Measurement

WeareconductingHEPA�ilterAirVelocityTestTodemonstratethattheHEPA�ilteriscapableofdeliveringairvelocities(90+/-20FPMor0.45m/sto0.50m/s)aspertheInternationalStandards.Theaverageair�lowvelocityiscalculatedbydividingthetotaloftheair�lowgridvelocitiesbythenumberofreadingstaken

We provide complete airborne particle countcleanliness classi�ication test As per GMPrecommendation with our MET ONE LaserParticleCounter.Itisperformedtodeterminetheactualparticlecountlevelwithinthefacilityatthetimeofthetest(As-Built,At-Rest,orperational).Particlesize(s)of interest, theroomoccupancystate and the room classi�ication should beknownpriortobeginthistest.

SpectroProvidescustomizedindustryspeci�iccleaningsolutions,foralltypesofcontrolledenvironment

Air Exchange Rate

Airexchangeratedeterminesthetotalairvolumegetsinthecleanroom.ThistestisperformedwithAirFlowCapturehood.Thehoodmeasuresairvolume�lowingthroughregisters,diffusersandgrills

Westrivetoprovidethebestserviceinthecleaning

industry,continuallyworkingtomeettheever-changing

needsofourclientele

Microbial Air Sampling Test

The sampling and analysis of airbornemicroorganisms in indoor air has receivedattention in recent years. Bioaersosolscontribute to about 5 to 34% of indoor airpollution.Sourcesofindoorbioaerosolsareoftenlocatedoutdoorsandparticlesaretransferredtothe inside throughopeningsof theCleanroomopenings(windows,doors).

Deferential Pressure, RH, TemperatureNoise and Light Intensity test

WealsoperformtheDifferentialpressuretestwithourPressureGaugeandManometer,RH,Temperature,NoiseandLightSensitivitywiththehelpofrespectiveProbesandsensors.

Page 3: SPECTRO's CLEAN ROOM SERVICES The Proven Choice for … · 2019-12-28 · air velocities (90+/-20 FPM or 0.45 m/s to 0.50m/s ) as per the International Standards. The average airlow

OUR KEY SERVICES

www.spectrogroup.com

Spectro understands the theory of critical environments. Our Staff is highly trained in criticalenvironmentprotocols, adheres to Federaland ISO standardsof complianceand is equippedwithLatestTechnologyandEquipments.

Our teamof trainedSupervisory staffandquality controlpersonnelhas the expertise required todesign and implementmaintenance programs for data centers of all types,manufacturing units,hospitals,Embassies,BPO'setc.

Spectro also stretch its activities for:-

è AmbientAirQualitySampling

è CompressedAirSampling(Moisture,OilAerosol,Particulate,MicrobesandGases)

è TotalOrganicCarbonSampling

è MicrobiologicalSamplingandEnumerationofSurface

è StackSampling(includingFugitiveEmission)

è IndoorairSampling&Analysis

è DatacenterorServerroomCorrosionMonitoring

è SurfaceandgroundwaterSampling

è Solid&HazardousWaste,Identi�ication&Characterization

è NoiseMonitoring&dataAnalysis

è MeteorologicalDataGeneration

Page 4: SPECTRO's CLEAN ROOM SERVICES The Proven Choice for … · 2019-12-28 · air velocities (90+/-20 FPM or 0.45 m/s to 0.50m/s ) as per the International Standards. The average airlow

E-41 Okhla Industrial Area Phase-IINew Delhi-110020Ph:- 91 11 40522000, 41611000E-mail: [email protected]:- www.spectrogroup.com www.spectro.in

Head Office Corporate Office

S-1 GNEPIP, Surajpur Industrial AreaKasna, Greater Noida, Phase-V

Gautam Budha Nagar (U.P.)Pin Code: 201308

Ph:- 0120-2341251/52 E-mail:- [email protected]

URL:- www.spectrogroup.com2017

Major Ac�vi�es

Testing

Calibration

Training

Inspection

R&D

Automation

Reverse Engineering

Ü Metals & Alloys

Ü Non Destructive Testing

Ü Rubber & Polymers

Ü Food and Agro Products

Ü Coal, Solid Fuels & Petroleum

Ü Electrical & Electronics

Ü Pharmaceuticals & Drugs

Ü Building Materials

Ü Minerals & Chemicals

Ü Leather & Textiles

Ü Water & Environment

Ü Paper & Packaging Materials

Ü Hazardous Substances

Ü Clean Room Validation

CIN:U74220DL1998PLC092698