spectrum power™ 4 - siemens españa

18
Infrastructure & Cities Sector © Siemens SA 2012 Spectrum Power™ 4 Distribution Management Applications Infrastructure & Cities Sector Energy Automation

Upload: others

Post on 04-Oct-2021

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities Sector© Siemens SA 2012

Spectrum Power™ 4Distribution Management ApplicationsInfrastructure & Cities SectorEnergy Automation

Page 2: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Definición

Spectrum Power™ 4Distribution Management Applications

Las aplicaciones de Spectrum Power™ 4 para la gestión de los sistemas de distribución (DMS)

añaden las siguientes funcionalidades:

� Gestión inteligente de llamadas de incidenciasen clientes (Trouble Call System)

� Gestión de descargos e incidencias (Outage Management)

� Automatización de la operación (Switching Procedure Management)

Page 2Nov-12

DMS

SCADA

Page 3: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications

� Operación de un gran número de subestación y elementos de red con gran cantidad de información asociada.

� Normalmente solo una parte de la red total esta telecontrolada y telemedida.

� Un fallo en la red afecta a la calidad del servicio y genera perdidas (clientes sin servicio).

� La red esta continuamente extendiéndose y reconfigurándose.

� Es necesario tener una referencia geográfica asociada a la topología de la red (sistema SIG asociado a los esquemas de red).

Page 3Nov-12

Características: redes de distribución

DMS

SCADA

Page 4: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications

� Infomación clara y actualizada de la red de distribución.

� Actualiación rápida y sencilla de la información de la red.

� Operación sencilla en las actuacionesprogramadas.

� Ayuda a la detección de fallos, su aislamiento y reconfiguración de la red.

� Optimización de la capacidad de la red.

� Minimización de los fallos en la red.

� Mejorar los tiempos de restauración del servício y los índices de calidad.

� Ayuda a la gestión corporativa de la red.

Page 4Nov-12

Requerimientos: redes de distribución

DMS

SCADA

Page 5: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications: SIG & SCADA

Page 5Nov-12

Capa 1Vista General.

Capa 3Conexión en subestación.

Capa 4Integración sobre mapa.

Capa 2Conexión de la red.

SIG DMS

RulesRules

TAGTAG

GIS

GIS

GISImportTools

GISImportTools

TAG/TATable

TAG/TATable

ATTRIBUTE

ATTRIBUTE

Integración SIG

Page 6: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications

� Herramientas para que el operador y el despachoque facilitan la:

� detección

� localización

� aislamiento

� reparación

� restauración

de los incidentes en la red y la programación de los descargos necesarios.

Page 6Nov-12

Outage Management System (OMS)

DMS

OMS

SCADA

Page 7: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications

� Planificación de descargos y tratamiento de incidentes.

� Índices de la calidad del servicio.

� Informes y estadísticas.

� Informes estándar (con ORACLE).

� Exportación a Excel.

Page 7Nov-12

Funcionalidades OMS

DMS

OMS

SCADA

Page 8: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications

� Provides convenient access to information necessary for tracking trouble calls

� Assists the operator in answering and recording customer telephone calls (which indicate loss of supply and other problems in the field)

� Analyses the problem and attempts to identify the reason for the outage

� TCS works closely with Outage Management System (OMS) for outage identification, tracking and resolution

Page 8Nov-12

Trouble Call System (TCS)

DMS

SCADA

TCS

Page 9: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications

� Summary of Outage Records

� Summary of Current Outage Equipments

� Summary of Trouble Call Events

� Summary of Trouble Tickets

� Summary View of Record Logs

� Display for individual Outage Record

� Creation of Records

Page 9Nov-12

Integración TCS & OMS

DMS

SCADA

TCS OMS

Page 10: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications

Page 10Nov-12

Substation

ProtectiveDevice 1a

ProtectiveDevice 1c

ProtectiveDevice 1d

ProtectiveDevice 1

t1-1t1a-1

t1a-2

t1a-3

t1a-5

t1a-4

t1c-4t1c-3

t1c-2

t1c-1

t1d-4

t1d-3

t1d-2

t1d-1

t1-4

t1-3

t1-2

t1-7t1-8

t1-5

t1-6

t1-9

t1d-5

OMS construye una relacciónentre las llamadas de los clientesy la red de distribución.

� Análisis de las llamadas de clientes

� Análisis gráfico de las llamadas

� Filtrado de los clientes afectados

� Histórico de las medidas tomadas

� Estadísticas e informes.

� Creación de órdenes de trabajo

Trouble Calls

Page 11: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications: DSPF

Page 11Nov-12

Distribution System Power Flow (DSPF)

DMS

SCADA

DSPF

OMSTCS

� Para redes de trifásicas balanceadas o no.

� Para tiempo real y simulación

� Ejecución

� Periódica

� Cuando la red cambia

� Bajo demanda

� Detección de violación de límites

Page 12: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications: DSPF

Page 12Nov-12

CARGASIMULACIÓN

Page 13: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications: DSPF

Page 13Nov-12

VISUALIZARESULTADOS

TABULAR

Page 14: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications: DSPF

Page 14Nov-12

VISUALIZARESULTADOS

GRÁFICO

Page 15: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications

Page 15Nov-12

Switching Procedure Management

DMS

SCADA

TCS OMS

SPM

Page 16: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4Distribution Management Applications

� Operación eficiente y resolutiva de la red de distribución.

� Reducción de costes en la operación, tiempo de resolución de incidencias y descargos.

� Mejora de los índices de calidad del servicio.

� Óptimo uso de las instalaciones de red y prolongación de su vida útil.

� Archivado del histórico de los incidentes de la red en formato estándar (accesible SQL).

� Facil integración con otros sistemas y aplicacionescorporativas (ej. SIG, SAP…)

Page 16Nov-12

Beneficios

DMS

DSPF

SPM

OMS

OFR VVC

CM

SCADA

TCS

Page 17: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Spectrum Power™ 4DMS– Selección de Referencias.

Austria EVN, KELAG,TIWAG

Germany GEW

Sweden Fortum

France EDF Paris

Spain IBERDROLA

Israel IEC

Venezuela ENELVEN

Colombia EPM

Singapore Singapore Power

China HEC Hongkong

Philippines Meralco

Abu Dhabi ADWEA

Page 17Nov-12

Page 18: Spectrum Power™ 4 - Siemens España

Infrastructure & Cities SectorEnergy Automation© Siemens SA 2012

Gracias por su atención.

Page 18 Nov-12

Manuel Romero Velázquez

Tlf. +34 95 503 7527

[email protected]

Centro de Control y Operación:

Tlf. +34 955 037 530

[email protected]