Spherical Tokamak Globus-M2: Design, Integration, Construction 1) Ioffe Physical-Technical Institute of the Russian Academy of Sciences, Saint Petersburg, Russia 2) JSC «NIIEFA», Saint Petersburg, Russia 3) JSC «INTEKHMASH», Saint Petersburg, Russia 4) Peter the Great St. Petersburg Polytechnic University, St. Petersburg, Russia 5) BINP SB RAS, Novosibirsk, Russia 6) Ioffe Fusion Technology Ltd., Saint Petersburg, Russia V.B. Minaev 1 , V.K. Gusev 1 , N.V. Sakharov 1 , V.I. Varfolomeev 1 , N.N. Bakharev 1 , V.A. Belyakov 2 , E.N. Bondarchuk 2 , F.V. Chernyshev 1 , V.V. Dyachenko 1 , A.D. Iblyaminova 1 , A.A. Kavin 2 , N.A. Khromov 1 , G.S. Kurskiev 1 , A.N. Labusov 2 , V.V. Mikov 3 , A.B. Mineev 2 , I.V. Miroshnikov 4 , M.I. Patrov 1 , Yu.V. Petrov 1 , V.A. Rozhansky 4 , A.N. Saveliev 1 , I.Yu. Senichenkov 4 , P.B. Shchegolev 1 , O.N. Shcherbinin 1 , I.V. Shikhovtsev 5 , V.V. Solokha 1 , V.N. Tanchuk 2 , A.Yu. Telnova 1 , V.A. Tokarev 1 , S.Yu. Tolstyakov 1 , E.G. Zhilin 6 This report employs the results, which have been obtained with the help of the unique scientific device spherical tokamak Globus-M. P.B. Shchegolev acknowledges RFBR, research project No. 16-32-00454 mol_a. Contacts: [email protected] References: [1] GUSEV, V.K., et al., Tech. Phys., 44 (1999) 9, 1054 [2] GUSEV, V.K., et al., Nucl. Fusion, 49 (2009) 10, #104021 [3] GUSEV, V.K., et al., Nucl. Fusion, 51 (2011) 10, #103019 [4] GUSEV, V.K., et al., Nucl. Fusion, 53 (2013) 9, #093013 [5] GUSEV, V.K., et al., Nucl. Fusion, 55 (2015) 10, #104016 [6] MINAEV, V.B., et al., Proc. of 24th IAEA conf., San Diego, 2012, ICC/P1-01 [7] MINAEV, V.B., et al., Proc. of 25th IAEA conf., St. Petersburg, 2014, FIP/P8-25 [8] SHCHERBININ, O.N., et al., Tech. Phys. Lett., 38 (2012) 10, 869 [9] BAKHAREV, N.N., et al., Nucl. Fusion, 55 (2015) 4, #043023 [10] GUSEV, V.K., et al., Plasma Phys. Control. Fusion, 58 (2015) 1, #014032 [11] Progress in the ITER Physics Basis, Nucl. Fusion, 47 (2007) 6, S18 [12] VALOVIC, M., et al., Nucl. Fusion, 49 (2009) 7, #075016 [13] SAVELIEV, A.N., IRZAK, M.A., SHCERBININ, O.N., (Proc. 38th EPS Conf. on Plasma Physics. Strasbourg, 2011, ECA Vol. 35G, P4.103) [14] ASKINAZI, L.G., et al., Nucl. Fusion, 55 (2015) 10, #104013 [15] SHCHEGOLEV, P.B., et al., (Proc. 43rd EPS Conf. on Plasma Physics. Leuven, 2016, ECA Vol. 40A, P1.065) [16] AVDEEVA, G.F., et al., Journal of Physics: Conf. Series 666 (2016) 012002 [17] AVDEEVA, G.F., et al., (Proc. 43rd EPS Conf. on Plasma Physics. Leuven, 2016, ECA Vol. 40A, P1.064) Introduction. The Globus-M spherical tokamak [1] has demonstrated practically all of the project objectives during the 15-year period of operation. The main factor limiting further enhancement of plasma parameters is a relatively low toroidal magnetic field [2-5]. The increase of the magnetic field up to 1.0 T together with the plasma current up to 0.5 MA will result in the significant enhancement of the operating parameters in the upgraded Globus-M2 machine [6,7]. The experimental program will be focused on plasma heating and non-inductive current drive [8-10] and will serve creation of physical and technological base for the compact fusion neutron source development. Construction, current status and plans Two novel thyristor rectifiers have been manufactured and delivered to the Ioffe Institute: one of them provides current swing of ± 70 kA amplitude in the central solenoid, another one supplies toroidal field coil with maximum current of 110 kA. Major repair of all electric grid transformers was made. Toroidal magnetic field and plasma current were increased by 25% from 0.4 T and 200 kA to 0.5 T and 250 kA respectively during last experimental campaign. One of the rectifiers was tested in the plasma experiment, feeding the current through the Globus-M central solenoid. In ohmically heated plasmas a significant growth of plasma stored energy was found, that indicates improvement of confinement due to toroidal magnetic field rise. The data were obtained from the analysis of plasma diamagnetism. Selected values of Wp were verified by kinetic measurements of electron temperature and density profiles. -80 -60 -40 -20 0 20 40 60 80 Ics (kA), SHOT #4237 0 250 50 100 150 200 Time (ms) Double swing current through the central solenoid Total plasma stored energy in the OH shots I B t =0.4 T, I p =200 kA K B t =0.5 T, I p =200 kA About 30% D-D neutron rate growth was observed after the plasma current and magnetic field increase. The main reasons for this are central electron temperature rise (from 600 eV to 900 eV) and the fast ion losses decrease. Reduction of the first orbit and slowing down losses of the injected particles and decrease of the saw-tooth oscillations impact on the energetic ion confinement resulted in the change of the CX spectra shape. - A fast scanning Langmuir probe diagnostic provides measurements of multiple plasma parameters in a midplane along the major radius for a 10 ms period at a depth of 6 cm. - Two 24-channel SPD diode arrays (∆E=1 - 40000 eV) are aimed at investigation of evolution of radiative losses spatial distribution. - Five additional channels were added to increase spatial distribution of Thomson scattering diagnostic on plasma periphery up to 1 cm. 0.16 0.17 0.18 0.19 0.20 0 5 10 15 20 25 30 neutron rate a.u. t, ms 0.5 T, 250 kA 0.4 T, 200 kA 0 5 10 15 20 25 30 35 1E7 1E8 1E9 Γ /E 1/2 , a.u. E, keV 0.4 T 200 kA 0.5 T 250 kA We plan one more experimental campaign with fully upgraded tokamak power supplies by the end of the year. Neutron flux and CX spectra during 26 keV D-NBI into D-plasma Ion and electron temperature measurements -TS, -NPA, , , -CXRS Some new diagnostic systems were developed: - CXRS measurements of ion temperature were performed in a simple 2-chord set-up [16]. The results are in agreement with NPA data [17]. A new 8-channel fiber-optical system is on the way. Replacing of existing magnets with new ones and first plasma are expected in 2017. Magnets for Globus-M2 have been manufactured and delivered to the Ioffe Institute. The structure of the magnetic field generated by the solenoid was measured during a special test experiment. А computer model of the solenoid was developed. Some asymmetry of the field relative to the equatorial plane, which is rapidly abated outward solenoid surface, may be caused by some irregularity in the coil pitch. Maps of surfaces of constant magnetic flux (left) and constant magnitude of poloidal magnetic field (right) for the Globus-M2 central solenoid 10 20 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 10 20 30 40 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 10 20 30 40 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 Z, cm Z, cm R, cm R, cm Design of the upgraded machine The electric current through the toroidal field coil reaches the value of 110 kA providing the magnetic field of 1.0 T. That is equal to 1.76 MA of total current in TF coil central rod. Current of ± 70 kA passes through the central solenoid providing magnetic flux variation of about 0.4 Wb. Globus-M Globus-M2, B-max Two basic plasma shot scenarios for the Globus-M2 tokamak t-max regime B T = 0.7 T (at R = 0.36m) Plasma current 0.5 MA 0.5 MA CS magnetic flux consumption 0.4 Wb (+/- 0.2 Wb) 0.4 Wb (+/- 0.2 Wb) Duration of TF flattop 0.4 s 0.7 s Basic regime Inductive Inductive / Non-inductive CD TF field rippling at R=0.6m 0.4% 0.4% Number of working pulses in regime with maximal load 5000 10000 Minimal pulse repetition rate Every 15 min Every 15 min Flexible bas bars are placed outside the maximal stresses zone. Bandage rings bear higher thermal and mechanical loads. Upper supporting ring and 4 load-bearing crosspieces are added. TF coil limbs are made of high grade copper (Ϭ 02 > 220 MPa). Water cooling is applied to all poloidal field coils. Central Column is redesigned completely. CS is wound in two layers in situ around the TF coil inner rod with a 1 mm gap. The temper hard copper conductor (Ϭ 02 > 290 MPa) of trapezoidal cross-section is used. Support structure is redesigned. PF1 and PF3 coils are redesigned. Fully revised design of magnets was developed for the upgraded tokamak. In Globus-M2 the vacuum vessel and the in-vessel components remain the same that allows reducing the project costs. Globus-M data extrapolation ASTRA and NUBEAM codes were used for simulations of the Globus-M2 high density deuterium shot (B t =1.0 T, I p =0.5 MA, <n e >=0.7×10 20 m -3 ) with D-NBI (30 keV, 1 MW). The electron thermal diffusivity was estimated with the help of two scalings: ITER IPB98(y,2) - pessimistic [11]; ST-scaling - optimistic [12]. The electron temperature exceeds 1.5 keV in the plasma core for both cases. ITER IPB98(y,2) ST-scaling Hydrogen ions with energy up to 100 keV, arising during IC heating, are well confined in Globus-M2. Absorption of input power increases due to improved antenna- plasma coupling [8]. 10 8 10 10 10 12 10 14 10 8 10 10 10 12 10 14 6.0×10 5 ×n e 0.36 ×B t 1.29 ×I P 1.34 ×E b 4.69 (10 19 m -3 , T, MA, keV) TUMAN-3M Globus-M Globus-M2 F n , s -1 The efficiency of low-hybrid current drive increases in Globus-M2. Both toroidal and poloidal launching are possible in general. Calculations predict that low-hybrid wave (2.45 GHz) application is able to provide fully non-inductive current regime for the 0.5 MW level of input power [13]. It is expected at least two orders of increase in the neutron flux rate during the deuterium beam injection into deuterium plasmas as compared with Globus-M [14]. NUBEAM simulation confirms this result [9]. ●● toroidal launch ▪▪ poloidal launch 16 keV 100 keV 0 4 8 12 0 20 40 60 80 100 1 T, 30 keV 1 T, 50 keV 0.4 T, 30 keV <n e >, 10 19 m -3 Direct losses (%) q=const 0,0 0,2 0,4 0,6 0,8 1,0 0,0 0,5 1,0 1,5 2,0 2,5 n e , 10 19 m -3 T e , T i [keV] r/a T e T i I BS = 138 kA I NBCD = 61 kA 0 5 10 15 P in = 1.9 MW P abs = 1.3 MW W tot = 20 kJ τ ST E = 16.6 ms τ E = 13.6 ms τ IPB98 E = 10.4 ms n e 0,0 0,2 0,4 0,6 0,8 1,0 0,0 0,5 1,0 1,5 2,0 2,5 T e T i 0 5 10 15 W tot = 13.5 kJ T e , T i [ keV] r/a n e , 10 19 m -3 n e P in = 1.8 MW P abs = 0.9 MW τ ST E = 21.4 ms τ E = 12.9 ms τ IPB98 E = 9.9 ms I BS = 82 kA I NBCD = 145 kA The percentage of direct losses during NB injection drops significantly in comparison with Globus-M conditions [9]. The direct losses of the main component of the 50 keV beam will not exceed 20% even for the moderate density regimes. About one third of the plasma current will be sustained non-inductively during injection of 1 MW beam with 50 keV energy. The fraction of the non-inductive current will attain the value of 45% in the case of application of both existing beam lines (1 MW, 50 keV and 1 MW, 40 keV) [15]. System integration Maximal NB energy is increased up to 40 keV for the existing 1 MW injector. In the sequel we plan to extend the beam pulse duration. Development of a new feeding system with grid power supplies is required thereto. A new 1 MW injector, which provides 50 keV atomic beam, will be applied in addition to the first one. Its pulse duration fits the maximal plasma shot length in Globus-M2. Both beams will be launched tangentially to the plasma column. Preliminary layout of the auxiliary heating systems and the main diagnostics The IC heating experiment will be continued on the Globus-M2 tokamak. A new double-strip antenna for the IC heating system has been manufactured. Upgrade of 2.45 GHz LHCD system is on the way. A new waveguide line with a divider of RF power provides transmission of about 0.5 MW of RF- power from the klystron to the antenna-grill. A new 10-waveguide grill provides rotation around its longitudinal axis during the installation and, as a result, changing of wave launching direction from toroidal to poloidal one and vice-versa. A new high voltage one second duration power supply was developed and manufactured for feeding of the klystron generator. Gas puff Langmuir probes Coaxial connectors Installation of new equipment requires some rearrangement of the diagnostic setup.

Upload: vanquynh

Post on 23-Feb-2018

234 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Spherical Tokamak Globus-M2: Design, Integration, Construction · PDF fileSpherical Tokamak Globus-M2: Design, Integration, Construction 1) Ioffe Physical-Technical Institute of the

Spherical Tokamak Globus-M2: Design, Integration, Construction

1) Ioffe Physical-Technical Institute of the Russian Academy of Sciences, Saint Petersburg, Russia2) JSC «NIIEFA», Saint Petersburg, Russia

3) JSC «INTEKHMASH», Saint Petersburg, Russia4) Peter the Great St. Petersburg Polytechnic University, St. Petersburg, Russia

5) BINP SB RAS, Novosibirsk, Russia6) Ioffe Fusion Technology Ltd., Saint Petersburg, Russia

V.B. Minaev1, V.K. Gusev1, N.V. Sakharov1, V.I. Varfolomeev1, N.N. Bakharev1, V.A. Belyakov2, E.N. Bondarchuk2, F.V. Chernyshev1, V.V. Dyachenko1, A.D. Iblyaminova1, A.A. Kavin2, N.A. Khromov1, G.S. Kurskiev1, A.N. Labusov2, V.V. Mikov3, A.B. Mineev2, I.V. Miroshnikov4,

M.I. Patrov1, Yu.V. Petrov1, V.A. Rozhansky4, A.N. Saveliev1, I.Yu. Senichenkov4, P.B. Shchegolev1, O.N. Shcherbinin 1, I.V. Shikhovtsev5, V.V. Solokha1, V.N. Tanchuk2, A.Yu. Telnova1, V.A. Tokarev1, S.Yu. Tolstyakov1, E.G. Zhilin6

This report employs the results, which have been obtained with the help of the unique scientific device

spherical tokamak Globus-M.P.B. Shchegolev acknowledges RFBR,

research project No. 16-32-00454 mol_a.Contacts: [email protected]

References:[1] GUSEV, V.K., et al., Tech. Phys., 44 (1999) 9, 1054[2] GUSEV, V.K., et al., Nucl. Fusion, 49 (2009) 10, #104021[3] GUSEV, V.K., et al., Nucl. Fusion, 51 (2011) 10, #103019[4] GUSEV, V.K., et al., Nucl. Fusion, 53 (2013) 9, #093013[5] GUSEV, V.K., et al., Nucl. Fusion, 55 (2015) 10, #104016[6] MINAEV, V.B., et al., Proc. of 24th IAEA conf., San Diego, 2012, ICC/P1-01[7] MINAEV, V.B., et al., Proc. of 25th IAEA conf., St. Petersburg, 2014, FIP/P8-25

[8] SHCHERBININ, O.N., et al., Tech. Phys. Lett., 38 (2012) 10, 869[9] BAKHAREV, N.N., et al., Nucl. Fusion, 55 (2015) 4, #043023[10] GUSEV, V.K., et al., Plasma Phys. Control. Fusion, 58 (2015) 1, #014032[11] Progress in the ITER Physics Basis, Nucl. Fusion, 47 (2007) 6, S18[12] VALOVIC, M., et al., Nucl. Fusion, 49 (2009) 7, #075016[13] SAVELIEV, A.N., IRZAK, M.A., SHCERBININ, O.N., (Proc. 38th EPS Conf. on

Plasma Physics. Strasbourg, 2011, ECA Vol. 35G, P4.103)

[14] ASKINAZI, L.G., et al., Nucl. Fusion, 55 (2015) 10, #104013[15] SHCHEGOLEV, P.B., et al., (Proc. 43rd EPS Conf. on Plasma Physics.

Leuven, 2016, ECA Vol. 40A, P1.065) [16] AVDEEVA, G.F., et al., Journal of Physics: Conf. Series 666 (2016) 012002[17] AVDEEVA, G.F., et al., (Proc. 43rd EPS Conf. on Plasma Physics. Leuven,

2016, ECA Vol. 40A, P1.064)

Introduction. The Globus-M spherical tokamak [1] has demonstrated practically all of the project objectives during the 15-year period of operation. The main factor limiting further enhancement of plasma parameters is a relatively low toroidal magnetic field [2-5]. The increase of the magnetic field up to 1.0 T together with the plasma current up to 0.5 MA will result in the significant enhancement of the operating parameters in the upgraded Globus-M2 machine [6,7]. The experimental program will be focused on plasma heating and non-inductive current drive [8-10] and will serve creation of physical and technological base for the compact fusion neutron source development.

Construction, current status and plans

• Two novel thyristor rectifiers have been manufactured and delivered to the Ioffe Institute: one of them provides current swing of ± 70 kA amplitude in the central solenoid, another one supplies toroidal field coil with maximum current of 110 kA.

• Major repair of all electric grid transformers was made.

• Toroidal magnetic field and plasma current were increased by 25% from 0.4 T and 200 kA to 0.5 T and 250 kA respectively during last experimental campaign. One of the rectifiers was tested in the plasma experiment, feeding the current through the Globus-M central solenoid.

• In ohmically heated plasmas a significant growth of plasma stored energy was found, that indicates improvement of confinement due to toroidal magnetic field rise. The data were obtained from the analysis of plasma diamagnetism. Selected values of Wp were verified by kinetic measurements of electron temperature and density profiles.

-80 -60 -40 -20

0 20 40 60 80 Ics (kA), SHOT #4237

0 250 50 100 150 200 Time (ms)

Double swing current through the central solenoid Total plasma stored energy in the OH shots

I Bt=0.4 T, Ip=200 kA K Bt=0.5 T, Ip=200 kA

• About 30% D-D neutron rate growth was observed after the plasma current and magnetic field increase. The main reasons for this are central electron temperature rise (from 600 eV to 900 eV) and the fast ion losses decrease.

• Reduction of the first orbit and slowing down losses of the injected particles and decrease of the saw-tooth oscillations impact on the energetic ion confinement resulted in the change of the CX spectra shape.

- A fast scanning Langmuir probe diagnostic provides measurements of multiple plasma parameters in a midplane along the major radius for a 10 ms period at a depth of 6 cm. - Two 24-channel SPD diode arrays (∆E=1 - 40000 eV) are aimed at investigation of evolution of radiative losses spatial distribution. - Five additional channels were added to increase spatial distribution of Thomson scattering diagnostic on plasma periphery up to 1 cm.

0.16 0.17 0.18 0.19 0.200

5

10

15

20

25

30

neut

ron

rate

a.u

.

t, ms

0.5 T, 250 kA 0.4 T, 200 kA

0 5 10 15 20 25 30 351E7

1E8

1E9

Γ/E1/

2 , a.

u.

E, keV

0.4 T 200 kA 0.5 T 250 kA

We plan one more experimental campaign with fully upgraded tokamak power supplies by the end of the year.

Neutron flux and CX spectra during 26 keV D-NBI into D-plasma Ion and electron temperature measurements

▪-TS, ▪-NPA,

▪, ▪, ▪-CXRS

• Some new diagnostic systems were developed: - CXRS measurements of ion temperature were performed in a simple 2-chord set-up [16]. The results are in agreement with NPA data [17]. A new 8-channel fiber-optical system is on the way.

Replacing of existing magnets with new ones and first plasma are expected in 2017.

• Magnets for Globus-M2 have been manufactured and delivered to the Ioffe Institute.

• The structure of the magnetic field generated by the solenoid was measured during a special test experiment.

• А computer model of the solenoid was developed.

• Some asymmetry of the field relative to the equatorial plane, which is rapidly abated outward solenoid surface, may be caused by some irregularity in the coil pitch.

Maps of surfaces of constant magnetic flux (left) and constant magnitude of poloidal magnetic field (right) for the Globus-M2

central solenoid

10 20

-40

-35

-30

-25

-20

-15

-10

-5

0

5

10

15

20

25

30

35

40

10 20 30 40

-40

-35

-30

-25

-20

-15

-10

-5

0

5

10

15

20

25

30

35

40

10 20 30 40

-40

-35

-30

-25

-20

-15

-10

-5

0

5

10

15

20

25

30

35

40Z, cm Z, cm

R, cm R, cm

Design of the upgraded machine

• The electric current through the toroidal field coil reaches the value of 110 kA providing the magnetic field of 1.0 T. That is equal to 1.76 MA of total current in TF coil central rod.

• Current of ± 70 kA passes through the central solenoid providing magnetic flux variation of about 0.4 Wb.

Globus-M

Globus-M2, B-max Two basic plasma shot scenarios for the Globus-M2 tokamak

t-max regimeBT = 0.7 T (at R = 0.36m)

Plasma current 0.5 MA 0.5 MA

CS magnetic flux consumption 0.4 Wb (+/- 0.2 Wb) 0.4 Wb (+/- 0.2 Wb)

Duration of TF flattop ≤ 0.4 s ≤ 0.7 s

Basic regime Inductive Inductive / Non-inductive CD

TF field rippling at R=0.6m ≤ 0.4% ≤ 0.4%

Number of working pulses in regime with maximal load 5000 10000

Minimal pulse repetition rate Every 15 min Every 15 min

Flexible bas bars are placed outside the maximal stresses zone.

Bandage rings bear higher thermal and mechanical loads.

Upper supporting ring and 4 load-bearing crosspieces are added.

TF coil limbs are made of high grade copper (Ϭ02 > 220 MPa).

Water cooling is applied to all poloidal field coils.

Central Column is redesigned completely. CS is wound in two layers in situ around the TF coil inner rod with a 1 mm gap. The temper hard copper conductor (Ϭ02 > 290 MPa) of trapezoidal cross-section is used.

Support structure is redesigned.

PF1 and PF3 coils are redesigned.

Fully revised design of magnets was developed for the upgraded tokamak.

In Globus-M2 the vacuum vessel and the in-vessel components remain the same that allows reducing the project costs.

Globus-M data extrapolation

• ASTRA and NUBEAM codes were used for simulations of the Globus-M2 high density deuterium shot (Bt=1.0 T, Ip=0.5 MA, <ne>=0.7×1020 m-3) with D-NBI (30 keV, 1 MW).

• The electron thermal diffusivity was estimated with the help of two scalings: ITER IPB98(y,2) - pessimistic [11]; ST-scaling - optimistic [12].

The electron temperature exceeds 1.5 keVin the plasma core for both cases.

ITER IPB98(y,2) ST-scaling

• Hydrogen ions with energy up to 100 keV, arising during IC heating, are well confined in Globus-M2.

• Absorption of input power increases due to improved antenna-plasma coupling [8].

108 1010 1012 1014108

1010

1012

1014

6.0×105×ne0.36×Bt

1.29×IP1.34×Eb

4.69

(1019m-3, T, MA, keV)

TUMAN-3MGlobus-MGlobus-M2

Fn, s-1

• The efficiency of low-hybrid current drive increases in Globus-M2.

• Both toroidal and poloidal launching are possible in general.

• Calculations predict that low-hybrid wave (2.45 GHz) application is able to provide fully non-inductive current regime for the 0.5 MW level of input power [13].

• It is expected at least two orders of increase in the neutron flux rate during the deuterium beam injection into deuterium plasmas as compared with Globus-M [14].

• NUBEAM simulation confirms this result [9].

●● toroidal launch ▪▪ poloidal launch

16 keV

100 keV

0 4 8 120

20

40

60

80

100

1 T, 30 keV1 T, 50 keV

0.4 T, 30 keV

<ne>, 1019m-3

Dire

ct lo

sses

(%)

q=const

0,0 0,2 0,4 0,6 0,8 1,00,0

0,5

1,0

1,5

2,0

2,5

n e,1019

m-3

T e,T

i[ke

V]

r/a

TeTi

IBS = 138 kAINBCD = 61 kA

0

5

10

15

Pin= 1.9 MWPabs= 1.3 MW

Wtot= 20 kJ

τSTE = 16.6 msτE= 13.6 msτIPB98

E = 10.4 ms

ne

0,0 0,2 0,4 0,6 0,8 1,00,0

0,5

1,0

1,5

2,0

2,5

TeTi

0

5

10

15Wtot= 13.5 kJ

T e,T

i [ke

V]

r/a

n e, 1019

m-3

ne

Pin= 1.8 MWPabs= 0.9 MW

τSTE = 21.4 msτE= 12.9 msτIPB98

E = 9.9 ms

IBS = 82 kAINBCD = 145 kA

• The percentage of direct losses during NB injection drops significantly in comparison with Globus-M conditions [9].

• The direct losses of the main component of the 50 keV beam will not exceed 20% even for the moderate density regimes.

• About one third of the plasma current will be sustained non-inductively during injection of 1 MW beam with 50 keV energy.

• The fraction of the non-inductive current will attain the value of 45% in the case of application of both existing beam lines (1 MW, 50 keV and 1 MW, 40 keV) [15].

System integration• Maximal NB energy is increased up to 40 keV for the existing 1 MW injector.

In the sequel we plan to extend the beam pulse duration. Development of a new feeding system with grid power supplies is required thereto.

• A new 1 MW injector, which provides 50 keV atomic beam, will be applied in addition to the first one. Its pulse duration fits the maximal plasma shot length in Globus-M2.

• Both beams will be launched tangentially to the plasma column.

Preliminary layout of the auxiliary heating systems and the main diagnostics

• The IC heating experiment will be continued on the Globus-M2 tokamak. A new double-strip antenna for the IC heating system has been manufactured.

• Upgrade of 2.45 GHz LHCD system is on the way. A new waveguide line with a divider of RF power provides transmission of about 0.5 MW of RF-power from the klystron to the antenna-grill.

• A new 10-waveguide grill provides rotation around its longitudinal axis during the installation and, as a result, changing of wave launching direction from toroidal to poloidal one and vice-versa.

• A new high voltage one second duration power supply was developed and manufactured for feeding of the klystron generator.

Gas puffLangmuir probes

Coaxial connectors

Installation of new equipment requires some rearrangement of the diagnostic setup.