SPN 58Syringe pump

The SPN 58 is a one channel drive syringe pump with LCD screen. It is easy to learn and operate with its clear user interface. It‘s ease of handling and quality make it popular worldwide.

© SternMed2

IBSCGMED-CPTA
Bas_de_page
stagiaire
Logo-2

POWERFUL FEATURES

• Body weight mode input

• Automatically calibrate syringe

• Automatically identify syringe size

• 3-level occlusion alarm limits

• Automatically reduce impact dose release after occlusion

• Delivered volume inquiry

•KVOflowrate(0.1ml/h~5.0mL/hadjustable)

• Multi-direction clamp for either horizontal or verticalfixation

• Operation error prompt

• Fast rate control

• “Purge” button activate safe protection

• Flow rate setting button lock

• Abundant optic and sound alarm

• AC and internal power indication

• Standard RS232 interface

•2000historyrecords

© SternMed3

IBSCGMED-CPTA
Bas_de_page
stagiaire
Logo-2

ALARMS

• Occlusion• Syringe empty • Finish• Syringe dislocated• Plunger/Clutchdisengaged• Battery low• Batteryexhausted• Power cable disconnected• Flow rate over limit• Volume over limit• System error• Non-operation time over• Shoulder Support padded

• Foot-rest padded• Radial Accessory clamp• Accessory clamp• Infusion Stand • Instrument tray• Drain pan

© SternMed 4

10,20,30,50mLofcalibratedsyringes0.1~1500mL/h(specifiedvalue0.1999.9mL/h,0.1mL/hstep) 50mLsyringe(specifiedvalue1000mL/horabove,1mL/hstep)0.1~900mL/h(0.1mL/hstep) 30mLsyringe0.1~600mL/h(0.1mL/hstep) 20mLsyringe0.1~400mL/h(0.1mL/hstep) 10mLsyringe5.0ml/h~1500ml/h 50mLsyringe5.0ml/h~900.0ml/h 30mLsyringe5.0ml/h~600.0ml/h 20mLsyringe5.0ml/h~400.0ml/h 10mLsyringeAccuracy including syringe: within +2%Mechanicalaccuracy:within+1%0.1~9999mL(0.1~999.9mL,0.1mLstep)(1000~9999mL,1mLstep)0.1~9999mL(0.1~999.9mL,0.1mLstep)(1000~9999mL,1mLstep)‘H’:800±200mmHg(106.7±26.7kPa)or1.09±0.27kgf/cm2‘C’:500±100mmHg(66.7±13.3kPa)or0.68±0.13kgf/cm2‘L’:300±100mmHg(40.7±13.3kPa)or0.41±00.13kgf/cm2‘Occlusion’,‘Nearlyempty’,Finish’,‘Syringedislocated’‘Plunger/Clutchdisengaged’,‘Batterylow’,‘Batteryexhausted’,‘Powercabledisconnected’,Flowrateoverlimit’,Volumeoverlimit’,Systemerror’.‘Non-operationtimeover’AC100+200V±10%,50~60Hz±1HzInnerNiMHbattery:DC12VContinuousoperationtimeofbattery:over6hoursforonechannelwhenbatteryisrechargedfor12hours,atflowrateof5mL/h.Ambienttemperature:5to40°C,Relativehumidity:20%to80%Ambienttemperature:-20to55°C,RelativeHumidity:<95%Classandinternalpowersupply:TypeCF,ContinuousoperationIPX42.25kg(withclampbase)306mm(Width)x135mm(Height)x127mm(Depth)

SyringesFlow rate

Purge rate

Accuracyofflowrate(Nominalvalue)Display range of volume deliveredSetting of delivery limitOcclusion detectionpressure

Alarms

Power

Operation conditions

Storage conditions