staad analysis and design
DESCRIPTION
steps on how to design a structure using staad software.TRANSCRIPT
STAAD ANALYSIS AND DESIGN
STAAD ANALYSIS AND DESIGNCE 2L/ SOFTWARE APPLICATIONRACHELLE A. CAPUL
OBJECTIVES:THIS OUTPUT AIMS TO PROPOSE A FIVE STOREY OFFICE BUILDING USING STAAD SOFTWARE. SPECIFICALLY, IT WILL:DESIGN THE STRUCTURAL MEMBERS BY THE AID OF STAAD USING UBC 1997 FOR SEISMIC ANALYSIS AND ACI-08 FOR CONCRETE DESIGN.FOLLOW THE STANDARDS SPECIFIED IN NSCP FOR THE APPLICATION OF LOADS.PROVIDE A SUMMARY OF THE STAAD ANALYSIS THAT THE DRAFTSMAN CAN EASILY UNDERSTAND.USE AND APPLY ALL THE KNOWLEDGE IN CE 2L/ SOFTWARE APPLICATION.STEPS IN STAAD ANALYSISCREATE YOUR PLAN USING THE COMMAND RUN STRUCTURE WIZARD AND MERGE IT INTO THE MODEL.CREATE THE STAIRS, MAKE IT PARALLEL IN VIEWING SIDEWAYS.ASSIGN PROPERTIES FOR ALL THE MEMBERS.DEFINE THE SEISMIC DATA USING UBC 1997. INPUT NEEDED VALUES USING STANDARDS IN NSCP.ASSIGN THE LOADS. (DEAD LOAD, AND VARIOUS LIVE LOADS).THESE LOADS SHOULD BE IN ACCORDANCE TO NSCPCOMPUTATIONS OF LOAD INPUTS
SEISMIC LOAD SPECIFICATIONS ACCORDING TO NSCP
STEPS IN STAAD ANALYSISGENERATE LOAD COMBINATIONS AND LOAD LIST.CREATE SUPPORTS BY DRAWING PLATES IN RUN STRUCTURE WIZARD. MERGE INTO MODELS AND APPLY SUPPORT. UNDER FOUNDATION, CHOOSE PLATE MAT AND ASSIGN.GENERATE SURFACE MESH AND APPLY IT TO THE STAIRS.START CONCRETE DESIGN AND DEFINE ALL THE PARAMETERS NEEDED. (E.G. FC, FY, CLB, ETC.)DESIGN THE BEAM, COLUMNS AND ELEMENTS/SLAB.STEPS IN STAAD ANALYSISPERFORM THE ANALYSIS AND WAIT FOR THE RESULTS.DOUBLE CHECK IF ALL THE MEMBERS HAVE CONCRETE DESIGN (ACI-08).MAKE SURE THAT THE DISPLACEMENT OF FOUNDATION IS NOT GREATER THAN 38MM. OTHERWISE, REVISE YOUR INPUTS AND ANALYZE AGAIN.BUILDING DRAWINGSPLANS, AND ELEVATION OF PROPOSED BUILDING
PROCESSING THE RESULTSDRAWING SHEAR AND MOMENT DIAGRAMS
PROCESSING THE RESULTS
TABULATING THE BARS OF THE BEAMSUNLESS OTHERWISE SPECIFIED, ALL GIRDERS ARE 500X300MM ; ALL FLOOR BEAMS ARE 450X300MMPROCESSING THE RESULTSTABULATING THE DESIGN MOMENTS AND LOADCASES
UNLESS OTHERWISE SPECIFIED, ALL GIRDERS ARE 500X300MM ; ALL FLOOR BEAMS ARE 450X300MMPROCESSING THE RESULTSTABULATING THE BARS, DESIGN MOMENTS AND LOADCASE OF COLUMNS
UNLESS OTHERWISE SPECIFIED, ALL COLUMNS ARE 500X500MM
REST SPACING OF TIES ARE 500MM OC.COLUMNS C-1 TO G-1PROCESSING THE RESULTSTABULATING THE AREAS OF BARS/MM OF FOOTING
PROCESSING THE RESULTSSUMMARY OF BARS OF FOOTING
USE WHICHEVER IS MAXIMUM.PROCESSING THE RESULTSCHECKING FOR THE SETTLEMENT OF FOOTINGS
SINCE MAXIMUM SETTLEMENT IS 30.7MM WHICH IS LESS THAN 38MM, THEREFORE, SETTLEMENT IS OKAY!PROCESSING THE RESULTSTABULATING FOR BARS OF STAIRS
END OF SLIDESHOWTHANK YOU FOR LISTENING