standard product ac-dc compactpci® · pdf fileinput fuse cpci ac rev. 00 page 2 of 9 a...
TRANSCRIPT
485-265Vac or 100-350Vdc input voltage ranges 44 outputs 4Output power 300W4Power Factor Correc� on EN61000-3-24Ac� ve very low inrush limita� on 4Surge and transient protec� on4Current sharing & N+1 redundancy43U x 8TE x 160mm
Safety IEC/EN 60950-1, RoHS lead-free-solder compliant
The CPCI AC, AC-DC CompactPCI® compliant with PICMG 2.11 standard, incorporates input and output protec� ons and fi ltering, signalling featu-res, required in severe environments for industrial, defense, avionic applica� ons. The PSU provides signifi cant advantages, high reliability thanks to the integra� on of Vicor Corp. modules, high effi ciency, low ripple and noise levels, input-to-output isola� on, so� start, MOFSET based ac� ve very low inrush limita� on circuit, overtemperature protec� on, input over/undervoltage lockout. The input is protected against surges and tran-sients and EMI fi ltered. The outputs are coun� nuously short-circuit proof . LEDs in front panel indicates the status of the psu.
CPCI ACStandard product AC-DC CompactPCI® 300W
CPCI AC Rev. 00 Page 1 of 9 www.powersystemtechnology.com
RoHS
-OUTVI4
+OUTVI3
+OUTVI5
C6
D2
HT-
384Vdc
+HT
-SH +SH
85-265 Vac
44-440HZ
C4
C2
AC-L
AC-N
F1 AC
2
AC
1
-+ PD1
VDR1 C5
+C7 +C8
R3
I Appel 0.8A max
EMI filtering, Active Inrush current limiting and PFC
R1
R2
R6C1
R7
R9
R8
R10
Carte commande CDPFCCSchéma électrique
CDPFCC
+SH
INH
-SH
CD
E
+VR
+HT
GL
-HT
GH
SI
CDE +VR +HTINH+SH-SHSI -HTGLGH
CDPFC1
+VR
+VR
-SH
+SH
INH
G
+HT
T1
T2
T3
T4
R4 R5
C3
R27
L1 L2
D1
21
L3
+HT
INHG
F3L5
L4
40Vdc Nom
VC
PC
TM
+IN
-IN
+OUT
-OUT
VTM
47,6V max
C20
+IN VI2
+IN
VI2
RTN
V1
T6
VCPC
TM
+IN
-IN
RE
SG
IF
+OUT
-OUT
PR
VS
NC
1N
C2
NC
3
NC
4
PRM
SG
RTN
IF
RE
9V
3v3
Ilimit 2V
R22
+IN
-In
+0ut1
PC
RSV
TM
+0ut2
-0ut1
-0ut2
BCM
C10
C11
C12
C13
F2
D3
48V
RT
N
HT-
PC
RTN
C37
V3
V4
V3 : +12V/2A
V4: -12V/0.6A
32V min
F4L7L6
39.6Vdc Nom
VC
PC
TM
+IN
-IN
+OUT
-OUT
VTM
45,6V max
V2: 3.3V/50AmaxC21
+IN VI4
+IN
VI4
RTN
V2
T8
VCPC
TM
+IN
-IN
RE
SG
IF
+OUT
-OUT
PR
VS
NC
1
NC
2N
C3
NC
4
PRM
SG1RTN
IF1
RE1
9V
3v3
Ilimit 2V
R26
D4
48V
RTN
PC
34.8V min
+OU
T V
I1
+OUT VI1
1/12
1/8R12
R14
+ C28
+ C14
+ C19
+ C27
+ C30 + C31 + C32
R11
R13
C29
C16
C18
C33
C9
C38
C39
C40
C41
C42
C43
+OUT VI1
PC
RTN
-VOUT7
Nc1
8
+VOUT6
+VIN2
Remote On/Off3
-VIN1
Nc2
5
-VOUT7
Nc1
8
+VOUT6
+VIN2
Remote On/Off3
-VIN1
Nc2
5
F5
VA
UX
12V
S R
TN
FA
L
INH
DE
G
EN
#
VA
UX
5VPC V4
V3
V2S
EN
SE
V1S
EN
SE
V1: 5V/40Amax
RT
N
S R
TN
RS
EN
SE
V1
V1S
EN
SE
OP
TR
EG
V1
V1S
HA
RE
RS
EN
SE
V1
RS
EN
SE
V2
RT
N
S R
TN
RS
EN
SE
V2
V2S
EN
SE
OP
TR
EG
V2
V2S
HA
RE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
J1
V1
V1
V1
V1
RTN
RTN
RTN
RTN
RTN
RTN
RTN
RTN
V2
V2
V2
V2
V2
V2
RTN
V3
V4
RTN
RTN
EN#
V1SENSE
V2SENSE
S RTN
V1SHARE
INH
V2SHARE
AC-N
AC-L
FAIL
DEG
VA
UX
5VV
AU
X5V
R28
V1S
EN
SE
R30
V2S
EN
SE
R31
R32
S R
TN
IPMB_PWR
CTN1
R36
T9
R40
T10
R42
R43
D5
C34 C35
C44 C45
C36 C46
C47
Protection and Control board
V3
4
V4
3
PC
2
Vau
x12v
1
Vau
x5V
5
SR
TN
6
FA
L
7
INH
8
DE
G
10
V2S
ense
11
V1S
ense
12
EN
#
13
SR
TN
9
Regulation and current sharing
1
1 1
1
V1
RT
N
1
Vau
x5V
2
SH
AR
EV
3
SR
TN
4
SE
NS
EV
5
OP
TO
RE
GV
6
RS
EN
SE
V
7
2
2
2
2
V2
Regulation and current sharing
RT
N
1
Vau
x5V
2
SH
AR
EV
3
SR
TN
4
SE
NS
EV
5
OP
TO
RE
GV
6
RS
EN
SE
V
7
PFC and inrush current control board
Features Features
Descrip� onDescrip� onDescrip� on
Bloc diagrammBloc diagrammBloc diagramm
Input Fuse
CPCI AC Rev. 00 Page 2 of 9 www.powersystemtechnology.com
A fuse mounted inside the converter protects against damages in case of a failure. The fuse is not user-accessible. In DC mode, reverse polarity at the input is protected and will not cause the fuse to blow .
Model Fuse type Ra� ng Reference
CPCI AC Schurter 5A 340300173
Input Transient Protec� on
A VDR (Voltage Dependent Resistor) and a common mode input fi lter form an eff ec� ve protec� on against input transients in severe environments.
Electrical Input Data
MIL-STD ruggedized (M)
Meet MIL-STD 461E CE102, MIL-STD 1399-300A, MIL-STD810E shock & vibra� ons. Laboratory cer� fi ca� on.-40°C opera� on (T)
The thermal grade of the Vicor the DC/DC converters used and other components are changed to comply with low ambiant temperature.
Op� ons Descrip� onOp� ons Descrip� onOp� ons Descrip� onOp� ons Descrip� onOp� ons Descrip� onOp� ons Descrip� on
Electrical Input DataElectrical Input Data
InputInput
Unit Characteristics Conditions min typ max
Operating input voltage 85 265 Vac Operating input voltage 100 350 Vdc Frequency 44 50 440 Hz Power Factor 230Vac, 50Hz, Pnom. 0,96 0,98 Input current At Vin min 4,1 A No-load input power At Vin typ 15 W Peak inrush current Vin max 4 A Start-up time 1 s
Input
Electrical Output DataGeneral condi� ons : 25°C ambiant.
OutputOutputElectrical Output DataElectrical Output Data
OutputOutput
Effi ciency curve
Power factor curve
Establisment � me curve
Unit Characteristics Conditions min typ max min typ max min typ max min typ max Output voltage 5 3V3 12 -12 V Set point accuracy 4,95 5,05 3,26 3,33 11,5 12,5 -11,5 -12,5 V Trim range 4,5 5,5 3 3,6 V Overvoltage protection 5,66 3,8 13,6 -13,6 V Output current 0 40 0 50 0 1 0 1 A Output current limit 48 59 1,5 1,5 A Output noise 20MHz 75 50 90 90 mVpp Line Regulation Vout nom. 0,05 0,05 0,05 0,05 % Load Regulation Vin nom. 0,1 0,1 1 3 %
Output V1 V2 V3 V4Max output power 325W overall
Conformal coa� ng (V)
During manufacturing process , when V op� on is specifi ed, components and pcb are covered with an acrylic coa� ng to address high level of ambiant humidity applica� on.61000-4-5 (Y)
Include a common mode surge protec� on 61000-4-5 Level 3 2KV based on gas discharger and VDR to meet criteria A. BE CAREFUL not to apply dielectric test if this op� on is choosen. If no Y op� on, criteria B is met.
Parallel opera� on & current share
CPCI AC Rev. 00 Page 3 of 9 www.powersystemtechnology.com
Redundant Systems Opera� on
Hold-up � me
The converters provide internal hold-up � me (see curve).
Hot Swap
The unit incorporates ac� ve limita� on by MOFSET with very low value of inrush current allowing hot swap opera� on. See curve.
Output Current Limita� on
All outputs are con� nously protected against short-circuit by a constant current limita� on (no foldback) with automa� c recovery. See Page 2 for the value.
Thermal Considera� ons
When a converter is mounted in free air, convec� on cooling and is ope-ra� ng at its nominal output power at the max. ambiant temperature, the temperature measured on the heatsink should not exeed 95°C. The dera� ng curves show the max power available from the converter ver-sus ambiant temperature.
Thermal protec� on & degrade signal
A temperature protec� on (OTP) is integrated in the unit, disabling output when heatsink temperature exceeds 90°C (+/-5°C). The con-verter automa� cally restarts, when the temperature drops below 55°C (+/-5°C). Nevertheless, exceeding the max opera� ng temperature may cause failures of the converter. A degraded signal (DEG), open collector, is provided when temperature exceed 80°C +/-5°C(ac� ve low) and is reset below 70°C +/-5°C. This can be monitored external system to reduce power and avoid thermal pro-tec� on. DEG is opened when temperature is within opera� ng range.
Parrallel opera� ng is possible for V1, V2 with ac� ve current sharing. The signals SHARE are single wire. All V1 SHARE of the diff erent psu in parrallel will have to be connected together. (Same for V2 SHARE).
When systems require a very high level of reliability and should work normally in the event of a failure, N+1 redundancy is implemented where N is the number of converter to support power requirement. If one converter fail, the remaining ones s� ll delivers the power to the loads.Redundant opera� on is directly provided without need of external diodes and is made internally by an ac� ve MOFSET circuit.(reduc� on of losses).
Overvoltage protec� on
An OVP is incorporated on each output. All outputs are cut if an OVP is detected. This protec� on is latch style (Recovery a� er AC reset or inhibit).
Hold up � me
Inrush current Ac� ve Limita� on
ĀȀ ĀЀ Ԁ ЀԀ ȀԀ Ԁ܀ Ԁࠀ Ԁ Ԁ Ԁ Ԁ Ԁ
Ȁ
Ѐ
ЀȀ
Ѐ
Ѐ
Ȁ
ȀȀ
Ȁ
Ȁ
܀
Ȁ܀
܀
ĀȀĀЀĀԀԀࠀ܀ࠀ܀ԀԀༀԀကᄀሀጀက᐀ࠀԀࠀᄀԀက᐀ᔀԀကጀᘀᜀ᠀Ԁ
ᤀᨀĀ
Ȁᰀ
Output power ambiant 2ms + 4ms
Output OVP value+5V 5,66V
+3V3 3,80V+12V 13,6V-12V -13,6V
Inhibit (Remote On/Off )
CPCI AC Rev. 00 Page 4 of 9 www.powersystemtechnology.com
A INH signal ac� vate & de-ac� vate the output voltages- outputs inhibited : INH level LOW
Output Voltage Adjustment
The converter outputs can be factory adjustable to diff erent values than standard ones. Consult factory.
Sense Lines
This feature enables compensa� on of voltage drop across the connec-tor contacts and the load lines. This fonc� onnality is implemented on V1 & V2 only. The voltage between any sense line and its respec� ve power output pin (as measured on the connector) should not exceed the following values at nominal output voltage.
Output type Total drop Posi� ve line drop
V1, V2 < 0.5V < 0.25V
Powerfail & LED
A FAIL signal (open collector) indicate the working state of the psu.The signal is open when all outputs voltage are in their range and "0" if one output is out of range.A single bi-color LED in the front panel indicates :- Green : Input OK- Red : output failure
WaveformsAuxiliary Func� onsAuxiliary Func� onsAuxiliary Func� onsAuxiliary Func� onsAuxiliary Func� onsoutput noise V1
Enable & IPMB_PWR
EN# signal ac� vates the psu when connected to ground.IPMB_PWR goes high when 5V output is OK
output noise V2
output noise V4output noise V3
OutputMinimum
valueMaximum
value+5V 4,40V 5,55V
+3V3 2,99V 3,65V+12V 10,7V 13,2V-12V -10,7V -13,1V
Electromagne� c Immunity
CPCI AC Rev. 00 Page 5 of 9 www.powersystemtechnology.com
Electromagne� c Emissions
Level according to EN55022A
Standard Level Value Waveform Source imped. Test procedure Mode Criteria
DM 1KV 1,2 / 50 µs 12 ohms OP BCM 2KV 1,2 / 50 µs 12 ohms OP BCM 2KV 1,2 / 50 µs 12 ohms Y option OP A
3EN 61000-4-5QualifiedSurges
OP B
Qualified
Qualified
10 pos., 10neg. OP B
Electrical fast transients/burst EN 61000-4-4 4 4000V 5 / 50µs 50 ohms
Electrostatic discharge (to case) EN 6100-4-2 4 8000V 1 / 50µs 330 Ohms
Electromagne� cElectromagne� cElectromagne� c
MIL-STD461E CE102 M op� on
Immunity to Environmental Condi� ons
Test method Standard Test conditions Status
20g / 18ms half size5g / 30ms
Vibrations 4-80Hz (2,8m/s²)²/Hz, non operating160-500Hz (0,175m/s²)²/Hz, non operating
MIL STD 167A-1A Non operating Qualified
MIL STD 810F Proc. 514-5 Qualified
Qualified
Damp Heat MIL STD 810F Proc. 507-2 Humidity 93 %, 40°C, 56 days Conformal coating option
only (V), qualified
Shock MIL STD 810F Proc.516.3
Note : Qualifi ed for EN 61000-4 -2, -3, -4, -5, -6, -11, EN 61000-3-2, EN 61000-3-3
CPCI AC Rev. 00 Page 6 of 9 www.powersystemtechnology.com
Solder side of the PCB protected by PBT sheet.
PD1
J1
T2T1
D1
T4
T6
T5
T8
T7
T3
CI1102011 IND01
1
CIE1
J4 J5
CI
Cover
Product label
EMI Gasket
100 mm
160 mm
167 mm
185 mm
40,5
mm
Mechanical dataMechanical dataMechanical data
Weight : 600g
Size : 3U x 8TE x 160mm
CPCI AC Rev. 00 Page 7 of 9 www.powersystemtechnology.com
Positronic 47 pts
Connector Pin Alloca� onConnector Pin Alloca� onConnector Pin Alloca� on
PIN1, 2, 3, 4 V1 Output 1 +
5, 6, 7, 8, 9, 10, 11, 12, 19, 22,
24RTN Outputs 0V
13, 14, 15, 16, 17, 18 V2 Output 2 +
20 V3 Output 3+21 V4 Output 4-
23, 25, 26, 28, 29, 31, 32, 36,
37, 40, 44NC Not Connected
27 EN# Enable30 V1 SENSE Remote sense V1+33 V2 SENSE Remote sense V2+34 S RTN Remote sense 0V35 V1 SHARE Current sharing V138 DEG Degrade mode signal39 INH Inhibition 41 V2 SHARE Current sharing V242 FAIL Signal Fail 43 IPMB_PWR45 EARTH Earth46 AC/N AC Neutral 47 AC/L AC Line
Positronic PCIH47M400A1/AADescription
CPCI AC Rev. 00 Page 8 of 9 www.powersystemtechnology.com
These converters are components, intended exclusively for integra� on into other equipment by an industrial assembly process or by a profes-sionally competent person. Installa� on must strictly follow the safety regula� ons in respect of the enclosure, moun� ng, creepage and clea-rance distances, markings of the end-use applica� on.Connec� on to the system shall be made via the female connector Po-sitronic.Pin 45 (Earth) is a leading pin and is connected to the case. For safety reasons it is essen� al to connect this pin to the protec� ve earth of the supply system.The AC/L is internally fused. This fuse is designed to protect the con-verter against overcurrent caused by a failure, but may not be able to sa� sfy all requirements. External fuses in the wiring circuit to one or both input pins (46 or 47) may be necessary to ensure compliance with local requirements.Do not open the converters, or the warranty will be invalidated. Make sure that there is suffi cient airfl ow available for convec� on cooling. This should be verifi ed by measuring the case of temperature at the speci-fi ed measuring point, when the converter is operated in the end-use
Cleaning Agents and Process
The converters are not herme� cally sealed. In order to avoid possible damage, any penetra� on of liquids shall be avoided.
Isola� on
The electric strength test is performed in the factory in accordance with IEC/EN 60950.
Standards and Approvals
The converters are built to meet the safety standards IEC 60950-1, EN 60950-1.‘Built to meet’ men� onned in the diff erent paragraphs of the datasheet means that Power System Technology has designed the product to meet the standard but not cer� fi ed it in a laboratory. ‘Qualifi ed’ means that the test has been made in a cer� fi ed laboratory.
Electric Strength
Design strength 1500 3000 500 Vrms
> 100 >100 MohmsInsulation resistance
Characteristic Output to Output
Unit
Electricstrength Factory test for production
units (>10s)2000 2000 500
Vdc
Input to Earth Input to Output
Output to Earth
Temperatures
ĀȀЀԀԀ܀ ȀЀ܀ࠀ
ЀȀЀԀȀЀ ༀЀက ༀᄀက ༀЀက ༀᄀက
ĀȀЀԀ܀ ࠀ ࠀ
ༀကࠀ ࠀ
ᄀ܀ሀጀԀ᐀ᔀ ࠀ ᘀ ࠀ ᘀ
ሀကࠀ ሀကࠀ
ᜀ᠀ᔀጀԀ܀Ѐ᐀ᤀᨀᔀᔀᤀᰀᔀጀԀ܀Ѐ᐀ᴀḀᔀԀ܀Ѐἀ
ሀ܀ᤀሀ᠀ᔀጀԀ܀Ѐ᐀
Reliability
MIL-HDBK-217F, notice 2 Model Heatsink Temp. GB GF40°C 285000 16500070°C 139500 82300100°C 86600 51000
MTBF ( Hours) CPCIAC
Safety & Installa� onSafety & Installa� on
These converters are components, intended exclusively for integra� on
Safety & Installa� onSafety & Installa� onSafety & Installa� onSafety & Installa� on
Note : If Y op� on is choosen, do not apply dielectric test.
CPCI AC Rev. 00 Page 9 of 9 www.powersystemtechnology.com
Max. power available : 300WIN max : see table page 2
CPCIAC 300 Op� on
MTVY
Op� ons and confi gura� onsOp� ons and confi gura� onsOp� ons and confi gura� ons
12
1 : 3,3V/50A, 5V/40A, 12V/1A, -12V/1A2 : 3,3V/50A, 5V/40A, 12V/5A, -12V/1A consult factory
CPCIDC consult factory