standard wall-mount...net unit weight (lbs) 23 shipping weight (lbs) 27 fan: type cross flow...
TRANSCRIPT
-
Multi-Zone System Indoor Unit
Multi F multi-zone comfort solutions are air-conditioning systems that “split” into indoor and outdoor units, providing a smart alternative to both central HVAC and window-mounted air conditioners. These Inverter heat pump systems are available in a
Multi F Standard Wall-Mounted Indoor Units
LG’s Multi F Standard Wall-Mounted indoor units have a curved architectural
clean look. Installation is simple—the units are designed to securely mount on a vertical surface using an included back plate. The removable, washable
-ble from the front of the unit without using tools. Each indoor unit includes its own wireless handheld remote controller; an LG-supplied wired controller is available separately.
Easy Comfort
-
uniform air distribution.Choose from Low, Med, High, Power Cool and Auto settings in Cooling mode; Low, Med, High, Power Heat and Auto settings in Heating mode. The Auto setting adjusts fan speed based on the difference between the controller setting and the room tempera-
direction, simulating a natural outdoor breeze. And Standard Wall-Mounted indoor units operate at sound levels no higher than 39 dB(A), contributing very little noise to the room.
Quality Commitment
LG is committed to the success of air-conditioning projects. We provide technical support during installation, and offer a variety of classes designed for installers and service providers. Classes are
the year and upon special request.
Benefits of Multi F Systems
Individual zone controlMaximum flexibilityOperating ranges of 14°F to 118°F (DB) in cooling and 0°F to 64°F (WB) in heatingQuiet and comfortable environmentSafer and easier installation with reduced ductwork Cost efficientLightweight and compact system components
About LG Electronics, Inc.LG Electronics, Inc. is a global leader and technology innovator in consumer electronics, mobile communi-cations, and home appliances, employing more than 213,000 people in more than 60 countries worldwide. LG’s commercial air conditioning business unit was established in 1968, and offers VRF, Multi F, duct-free split systems, packaged terminal air conditioners (PTACs), and room air conditioners.
With LG, it’s all possible.™
MULTI F
Standard Wall-Mount
-
Features
Inverter (Variable speed fan)Chaos SwingJet Cool Jet Heat
Self-cleaning indoor coilAuto operationAuto restart Plasma filter
Includes wireless LCD remote controller, batteries, holder and holder hardware; wired controller available as an option
LMN097HVT
9,000 Btu/h Nominal Cooling Capacity10,400 Btu/h Nominal Heating Capacity
LMN127HVT
12,000 Btu/h Nominal Cooling Capacity13,800 Btu/h Nominal Heating Capacity
LMN187HVT
18,000 Btu/h Nominal Cooling Capacity20,800 Btu/h Nominal Heating Capacity
Warranty: Five (5) years parts.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
DFS-PB-AJ-009-US 013M18
LMN097-127-187HVT
Model Number LMN097HVT LMN127HVT LMN187HVT
Nominal Cooling Capacity (Btu/h) 9,000 12,000 18,000
Nominal Heating Capacity (Btu/h) 10,400 13,800 20,800
Fan
Type Cross Flow Cross Flow Cross Flow
Motor Output (W) x Qty. 14.4 x 1 14.4 x 1 76.0 x 1
Motor/Drive Brushless Digitally Controlled / Direct Brushless Digitally Controlled / Direct Brushless Digitally Controlled / Direct
Airflow Rate (H/M/L) (CFM) 247 / 230 / 212 335 / 318 / 300 572 / 501 / 434
Unit Data
Refrigerant Type / Control R410A / EEV R410A / EEV R410A / EEV
Power Supply (Phase / V / Hz) 1 / 208-230 / 60 1 / 208-230 / 60 1 / 208-230 / 60
Rated Amps (A) 0.2 0.2 0.3
Sound Pressure Level ±3 dB(A) (H/M/L) 33 / 30 / 27 39 / 36 / 31 37 / 33 / 28Dimensions (W x H x D, in.) 35-1/4 x 11-3/8 x 8-1/16 35-1/4 x 11-3/8 x 8-1/16 40-9/16 x 12-25/32 x 9-5/8
Net Unit Weight (lbs.) 23 23 32
Shipping Weight (lbs.) 27 27 37
Power Wiring / Communications Cable(No. x AWG)
4 x 18 4 x 18 4 x 18
Heat Exchanger(Row x Column x Fin / inch) x Number
(2 x 16 x 23) x 1 (2 x 16 x 23) x 1 (3 x 18 x 22) x 1
Piping
Liquid (in.) 1/4 1/4 1/4
Vapor (in.) 3/8 3/8 1/2
Drain O.D. / I.D. (in.) 27/32 / 5/8 27/32 / 5/8 27/32 / 5/8
Art Cool™ Standard Wall-Mounted Multi F System Indoor Unit
-
Date:
Job Name/Location:
PO No.:
Architect:Engr:
GC:
Rep:
For: File
Approval
Mech:
Resubmit
Other
Tag #:
(Company) (Project Manager)
LMN097HVTMulti F Standard
Btu/h Indoor Unit9,000Performance:
Nominal Cooling Capacity (Btu/h) 9,000
Cooling Nominal Test Conditions: Heating Nominal Test Conditions:Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WBOutdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F WB
Electrical:Power Supply (V¹/Hz/Ø) 208 230/60/1
Rated Amps (A) 0.20
Piping:Liquid Line (in, OD) 1/4
Vapor Line (in, OD) 3/8
Controls Features: •4 Way auto swing •24 Hour on/o mer •Auto opera on(artificial intelligence) •Auto restart •Chaos wind •Inverter(variable speed fan)
•Jet Cool/Jet Heat •Plasma air purifying system •Self cleaning indoor coil •Sleep mode •Condensate sensor
connection •Group control
Optional Accessories:
ACP Premium PQCPC22A1ACP Standard PQCPC22N1LonWorks Gateway PQNFB16A1BACnet Gateway PQNFB17B0
Drain OD, ID (in) 13/16, 5/8
Temperature Sensor Thermistor
Entering Mixed Air:
Cooling (°F DB) 57 77
Heating (°F DB) 59 81
Unit Data:Refrigerant Type R410A
Refrigerant Control EEV
Sound Pressure² H/M/L (±3 dB(A)) 33/30/27
Primary Filter Washable Pre filter
Secondary Filter Plasma
Net Unit Weight (lbs) 23
Shipping Weight (lbs) 27
Fan:
Type Cross Flow
Quantity 1
Motor/Drive Brushless Digitally Controlled/Direct
Airflow Rate H/M/L (CFM) 247/230/212
Notes: 1.Acceptable opera ng voltage: 187V 253V. 2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 3.See Engineering Manual for sensible and latent capaci es. 4.All power/communica on cable to be minimum 18 AWG, 4 conductor, stranded,
shielded and must comply with applicable local and national code. 5.Power wiring cable size must comply with the applicable local and na onal code. 6.This unit comes with a dry helium charge. 7.Corresponding refrigerant piping length is in accordance with standard length of each
outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratiobetween 95 – 105%
8.Must follow installa on instruc ons in the applicable LG installa on manual.
Page 1 of 2DFS SB AD 018 US 013K10For continual product development, LG reserves the right to change specifications without notice.© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lg dfs.com
Simple Controller with Mode (Black) PQRCVCL0Q
Simple Controller without Mode (Black) PQRCHCA0QSimple Controller with Mode (White) PQRCVCL0QW
Simple Controller without Mode (White) PQRCHCA0QW
LG Programmable Thermostat PREMTB10U
AC Smart Premium PQCSW421E0A
Dry Contact Unit (1 contact, 24 VAC external power) PQDSB1Dry Contact Unit (2 input, power from indoor unit) PQDSBCDry Contact for third party thermostat PQDSBNGCM1
Included Accessories:•Wireless Handheld Remote Controller AKB73635606
Nominal Heating Capacity (Btu/h) 10,400
-
Job Name/Location:
Tag #:Date:PO No.:
LMN097HVTMulti F Standard
Btu/h Indoor Unit9,000
Page 2 of 2DFS SB AD 018 US 013K10For continual product development, LG reserves the right to change specifications without notice.© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lg vrf.com
-
Date:
Job Name/Location:
PO No.:
Architect:Engr:
GC:
Rep:
For: File
Approval
Mech:
Resubmit
Other
Tag #:
(Company) (Project Manager)
LMN127HVTMulti F Standard
Btu/h Indoor Unit12,000Performance:
Nominal Cooling Capacity (Btu/h) 12,000
Cooling Nominal Test Conditions: Heating Nominal Test Conditions:Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WBOutdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F WB
Electrical:Power Supply (V¹/Hz/Ø) 208 230/60/1
Rated Amps (A) 0.20
Piping:Liquid Line (in, OD) 1/4
Vapor Line (in, OD) 3/8
Controls Features: •4 Way auto swing •24 Hour on/o mer •Auto opera on(artificial intelligence) •Auto restart •Chaos wind •Inverter(variable speed fan)
•Jet Cool/Jet Heat •Plasma air purifying system •Self cleaning indoor coil •Sleep mode •Condensate sensor
connection •Group control
Optional Accessories:
ACP Premium PQCPC22A1ACP Standard PQCPC22N1LonWorks Gateway PQNFB16A1BACnet Gateway PQNFB17B0
Drain OD, ID (in) 13/16, 5/8
Temperature Sensor Thermistor
Entering Mixed Air:
Cooling (°F DB) 57 77
Heating (°F DB) 59 81
Unit Data:Refrigerant Type R410A
Refrigerant Control EEV
Sound Pressure² H/M/L (±3 dB(A)) 39/36/31
Primary Filter Washable Pre filter
Secondary Filter Plasma
Net Unit Weight (lbs) 23
Shipping Weight (lbs) 27
Fan:
Type Cross Flow
Quantity 1
Motor/Drive Brushless Digitally Controlled/Direct
Airflow Rate H/M/L (CFM) 335/318/300
Notes: 1.Acceptable opera ng voltage: 187V 253V. 2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 3.See Engineering Manual for sensible and latent capaci es. 4.All power/communica on cable to be minimum 18 AWG, 4 conductor, stranded,
shielded and must comply with applicable local and national code. 5.Power wiring cable size must comply with the applicable local and na onal code. 6.This unit comes with a dry helium charge. 7.Corresponding refrigerant piping length is in accordance with standard length of each
outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratiobetween 95 – 105%
8.Must follow installa on instruc ons in the applicable LG installa on manual.
Page 1 of 2DFS SB AD 020 US 013K10For continual product development, LG reserves the right to change specifications without notice.© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lg dfs.com
Simple Controller with Mode (Black) PQRCVCL0Q
Simple Controller without Mode (Black) PQRCHCA0QSimple Controller with Mode (White) PQRCVCL0QW
Simple Controller without Mode (White) PQRCHCA0QW
LG Programmable Thermostat PREMTB10U
AC Smart Premium PQCSW421E0A
Dry Contact Unit (1 contact, 24 VAC external power) PQDSB1Dry Contact Unit (2 input, power from indoor unit) PQDSBCDry Contact for third party thermostat PQDSBNGCM1
Included Accessories:•Wireless Handheld Remote Controller AKB73635606
Nominal Heating Capacity (Btu/h) 13,800
-
Job Name/Location:
Tag #:Date:PO No.:
LMN127HVTMulti F Standard
Btu/h Indoor Unit12,000
Page 2 of 2DFS SB AD 020 US 013K10For continual product development, LG reserves the right to change specifications without notice.© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lg vrf.com
-
Date:
Job Name/Location:
PO No.:
Architect:Engr:
GC:
Rep:
For: File
Approval
Mech:
Resubmit
Other
Tag #:
(Company) (Project Manager)
LMN187HVTMulti F Standard
Btu/h Indoor Unit18,000Performance:
Nominal Cooling Capacity (Btu/h) 18,000
Cooling Nominal Test Conditions: Heating Nominal Test Conditions:Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WBOutdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F WB
Electrical:Power Supply (V¹/Hz/Ø) 208 230/60/1
Rated Amps (A) 0.30
Piping:Liquid Line (in, OD) 1/4
Vapor Line (in, OD) 1/2
Controls Features: •4 Way auto swing •24 Hour on/o mer •Auto opera on(artificial intelligence) •Auto restart •Chaos wind •Inverter(variable speed fan)
•Jet Cool/Jet Heat •Plasma air purifying system •Self cleaning indoor coil •Sleep mode •Condensate sensor
connection •Group control
Optional Accessories:
ACP Premium PQCPC22A1ACP Standard PQCPC22N1LonWorks Gateway PQNFB16A1BACnet Gateway PQNFB17B0
Drain OD, ID (in) 13/16, 5/8
Temperature Sensor Thermistor
Entering Mixed Air:
Cooling (°F DB) 57 77
Heating (°F DB) 59 81
Unit Data:Refrigerant Type R410A
Refrigerant Control EEV
Sound Pressure² H/M/L (±3 dB(A)) 37/33/28
Primary Filter Washable Pre filter
Secondary Filter Plasma
Net Unit Weight (lbs) 32
Shipping Weight (lbs) 37
Fan:
Type Cross Flow
Quantity 1
Motor/Drive Brushless Digitally Controlled/Direct
Airflow Rate H/M/L (CFM) 572/501/434
Notes: 1.Acceptable opera ng voltage: 187V 253V. 2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 3.See Engineering Manual for sensible and latent capaci es. 4.All power/communica on cable to be minimum 18 AWG, 4 conductor, stranded,
shielded and must comply with applicable local and national code. 5.Power wiring cable size must comply with the applicable local and na onal code. 6.This unit comes with a dry helium charge. 7.Corresponding refrigerant piping length is in accordance with standard length of each
outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratiobetween 95 – 105%
8.Must follow installa on instruc ons in the applicable LG installa on manual.
Page 1 of 2DFS SB AD 021 US 013K10For continual product development, LG reserves the right to change specifications without notice.© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lg dfs.com
Simple Controller with Mode (Black) PQRCVCL0Q
Simple Controller without Mode (Black) PQRCHCA0QSimple Controller with Mode (White) PQRCVCL0QW
Simple Controller without Mode (White) PQRCHCA0QW
LG Programmable Thermostat PREMTB10U
AC Smart Premium PQCSW421E0A
Dry Contact Unit (1 contact, 24 VAC external power) PQDSB1Dry Contact Unit (2 input, power from indoor unit) PQDSBCDry Contact for third party thermostat PQDSBNGCM1
Included Accessories:•Wireless Handheld Remote Controller AKB73635606
Nominal Heating Capacity (Btu/h) 20,800
-
Job Name/Location:
Tag #:Date:PO No.:
LMN187HVTMulti F Standard
Btu/h Indoor Unit18,000
Page 2 of 2DFS SB AD 021 US 013K10For continual product development, LG reserves the right to change specifications without notice.© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lg vrf.com
Job Name/Location: Tag #: Date: File: OffPO No: Approval: OffResubmit: OffOther: OffOther Field: Architect: GC: Engr: Mech: Company: Project Manager: LG Programmable Thermostat PREMTB10U: OffSimple Controller with Mode Black PQRCVCL0Q: OffSimple Controller with Mode White PQRCVCL0QW: OffSimple Controller without Mode Black PQRCHCA0Q: OffSimple Controller without Mode White PQRCHCA0QW: OffAC Smart Premium PQCSW421E0A: OffACP Premium PQCPC22A1: OffACP Standard PQCPC22N1: OffLonWorks Gateway PQNFB16A1: OffBACnet Gateway PQNFB17B0: OffDry Contact Unit 1 contact 24 VAC external power PQDSB1: OffDry Contact Unit 2 input power from indoor unit PQDSBC: OffDry Contact for third party thermostat PQDSBNGCM1: Off