standards update 2014 jonathan jew 2014-02-28 in progress • iso/iec tr 11801‐99‐1 – balanced...

38

Upload: vanquynh

Post on 20-May-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

What BICSI, TIA, & ISO/IEC are doing with standards and why 

you should care

Jonathan Jew ‐ J&M Consultants, Inc.Co‐chair BICSI Data Center SubcommitteeChair TIA TR‐42.6 Telecom Administration

Vice‐chair TIA TR‐42.1 Generic & Premises CablingVice‐chair USTAG to ISO/IEC JTC 1 SC 25 WG 3

www.j‐and‐m.com

The organizations in this update• ISO/IEC – ISO/IEC JTC 1 SC 25 WG 3 –international telecommunications cabling standards

• TIA (Telecommunications Industry Association) TR‐42 – US and Canadian national telecommunications cabling standards

• BICSI – international standards and guidelines for information technology systems

The organizations in this update• ISO/IEC JTC 1 SC 25 includes experts from 29 countries & observers from 18 other countries

• TIA TR‐42 includes experts from 60+ US and Canadian organizations

• BICSI Standards includes 400+ members, mostly from the end‐user and consultant community

The organizations in this update

• All three organizations are all very busy –probably busier than they ever have been

Why you should care about standards• Ensures that the cabling system works properly • Ensures cabling system is easy to use and maintain

• Combined knowledge of many of the best industry experts in their respective fields

• Standards are an inexpensive way for you to learn from these experts and apply their knowledge to your projects

ISO/IEC Standards

Dashed lines= in progress

ISO/IEC Recently Published• ISO/IEC 24764‐1 ‐ Data Centres ‐ Amendment to add Intermediate Distributor (ID) for large or modular data centers 

• For data center designers using ISO/IEC 24764

ISO/IEC In Progress• ISO/IEC 14763‐3 Edition 2 – Testing of Optical Fibre Cabling – methods for inspection and testing of installed optical fiber 

• For those who test optical fiber installed per ISO/IEC standards

• Expected publication in 2014

ISO/IEC In Progress• ISO/IEC TR 11801‐99‐1 – Balanced cabling for 40Gbps channels – (2014‐2015) meant for IEEE

• Characterizes 30 meter channels (26 m with 2x2m patch cords) to support 40 Gbps using existing Cat 6A, 7, 7A, and new Cat 8.1 and Cat 8.2 components

• Cat 8.1 for Class I channels is backward compatible with Cat 6A

• Cat 8.2 for Class II channels compatible with Cat 7/7A• IEEE 40GBase‐T target is 30 m for Cat 8, unknown for Cat 6A, 7, 7A

• Parallel effort in TIA underway

ISO/IEC In Progress• 3rd Edition of ISO/IEC 11801 series & reorganization of related standards (‐1 General,  ‐2 Offices, ‐3 Industrial, ‐4 Homes, ‐5 Data Centres) estimated publication 2016 – no more Cat 3, OM1, OM2.  For those who use ISO/IEC standards 

• ISO/IEC 30129 – Telecommunications Bonding   ‐New standard based on ANSI/TIA‐607‐B and CENELEC EN 50310 ‐ estimated 2015‐2016 ‐ For those who specify telecom bonding & grounding

ISO/IEC In Progress• ISO/IEC 11801‐6 Distributed Building Services – based on CENELEC EN 50173‐6 and ANSI/TIA‐862‐A – estimated publication 2016

• Cabling for wireless access points, building energy management, environmental control, access control, security, safety, paging, patient monitoring, etc.

• For all structured cabling designers

ISO/IEC In Progress• Addendum to ISO/IEC 14763‐2 – core & optional Automated Infrastructure Management (AIM) functions – 2014 

• ISO/IEC 18598 AIM System Requirements, Data Exchange, and Applications – 2016  –requirements and recommendations for AIM systems, benefits of AIM, model for data exchange (between AIM systems and from AIM systems to other network and building management systems) ‐ for those who are planning or considering AIM

TIA standards structure

Dashed lines= in progress

TIA – Published in 2013 & 2014• ANSI/TIA‐942‐A‐1 Data Center Fabrics

Types of data center fabric architectures (e.g., fat tree or full mesh) and how to support them using structured cabling– Low‐latency switch fabric that is non‐blocking, permitting any port to communicate with any other port at the full capacity of the port

– Switch fabrics are needed for cloud computing and may be needed for virtualization

– For data center cabling designers

TIA – Published in 2013 & 2014• ANSI/TIA‐569‐C.1 – Revised Temperature and Humidity Requirements– Adopts revised 2012 ASHRAE thermal guidelines for data processing environments

– Wider temperature and humidity ranges for computer rooms and equipment rooms resulting in energy savings

– For data center designers and owners– Maximum balance twisted‐pair cabling distances are reduced above 20o C 

– E.G., at 60o C max permanent link = 75 m for UTP

TIA – Published in 2013 & 2014• TIA TSB‐4979 Practical Considerations for Implementation of Encircled Flux Launch Conditions in the Field– Information for users to understand encircled flux and the options for using it

– Using encircled flux reduces optical loss measurement uncertainty and increases consistency when performed with different sources & should be a requirement in contracts

– For those who test or specify fiber testing

TIA – Published in 2013 & 2014• ANSI/TIA‐607‐B‐2 – Structural Metal Addendum– Harmonizes with ISO/IEC 30129 Telecom Bonding standard in development

– Permits the use of an electrically continuous building structural metal frame to be used in place of a dedicated telecommunications bonding backbone

– For those who design or specify telecom bonding

TIA – Published in 2013 & 2014• ANSI/TIA‐TSB‐162‐A – cabling guidelines for wireless access points– For designers of wireless LANs– Guidelines for designing cabling for WLANs.  Changes include:• Recommends multiple outlets, Category 6A, or OM3 MMF to support higher bandwidth requirements of new wireless standards (e.g., 7.3 Gbps for IEEE 802.11ac)

• More access point mounting options and physical security information

TIA – Published in 2013 & 2014• ANSI/TIA‐4966 Educational Facilities

– Approved in early 2014– New standard for cabling of educational buildings and spaces (elementary schools, middle schools, high schools, colleges, universities, and training rooms)

– Suggested density of wireless access points– Informative annex on distributed antenna systems– Typical class room layouts– For designers of cabling for educational buildings

TIA Standards in Development• TIA‐568‐C.2‐1 Category 8 (2014/early 2015)• Similar to ISO/IEC Category 8.1 (screened cable that uses 8‐pin ‘RJ45’ jack)

• Uses 24 m permanent link with 2 x 3 m cords (2 x 4 m with solid‐conductor cords)

• Considering Category 8.2/Class II• Consider 24 m cabling distances for new data center designs to permit upgrade to Cat 8

TIA Standards in Development• TIA‐604‐18‐A / FOCIS‐18 Type MPO‐16 fiber• Specification for 16‐ and 32‐fiber MPOs• Estimated 2014• For manufacturers of MPO connectors• Permits better utilization of optical fibers than MPO‐12 because 40G and 4‐lane 100G Ethernet use 8 fibers.  400G Ethernet may use 32 MM fibers.

TIA Standards in Development• TIA‐568.0‐D, TIA‐568.1‐D, TIA‐568.2‐D, TIA‐568.3‐D, TIA‐569‐D – Updates to base standards 

• Changes being considered: recognize broadband coaxial cable (TIA‐568‐C.4), 2‐fiber minimum, recommend Cat 6A and OM3 or higher, add Cat 8, PON splitter/coupler specs

• important to all who use TIA standards –estimated 2015‐2016 (568.0‐D, 568.1‐D, and 569‐D will publish before 568.2‐D and 568.3‐D)

TIA Standards in Development• TIA‐4994 ‐ Sustainability • To be used with Sustainable Technology Environments Program (STEP) to provide best practices and rating similar to LEED, but for information communications technology (ICT)

• Estimated late‐2014/2015• For anyone interested in sustainability• Related new TIA project for sustainable ICT manufacturers approved Jan 2014

TIA Standards in Development• TIA‐607‐C bonding and grounding (earthing)  update to TIA‐607‐B ‐ harmonize with ISO/IEC 30129 where possible, integrate annexes on antenna grounding and building steel 

• For those who specify telecom grounding & bonding

• Estimated 2015

TIA Standards in Development• TIA‐862‐B Cabling for Intelligent Building Systems ‐ (2015) update to TIA‐862‐A building automation systems– covers cabling for all types of building systems

• Significant debate regarding additional restrictions or guidance for direct connections to equipment (without outlet or horizontal connection point)

• For all telecom cabling designers

TIA Standards in Development• TIA Physical Network Security – draft under development ‐ Target late‐2015

• Installation, management, and design practices for physical security of telecommunications cables, pathways, spaces

• Contributions from TIA members and consultants that work on high‐security government/military installations

• For any telecom designer/owner

BICSI• Intended to complement rather than replace cabling standards such as TIA or ISO/IEC by providing best practices for design & implementation

• Also intended to supplement BICSI publications such as recently published TDMM 13th Edition (by providing more detail)

• Over 400 volunteer subject matter experts, POSSIBLY INCLUDING YOU!

BICSI – Recently Published• BICSI‐004 Health Care (published Dec 2012) –get this and TIA‐1179 if you design cabling for health care facilities (e.g., clinics, hospitals, nursing homes)

• BICSI‐005 Electronic Safety and Security (ESS) (published 2013) – get this if you design cabling for security and safety systems 

BICSI – Recently Published• BICSI‐003 – Building Information Modeling (BIM) Practices (Intelligent 3‐D CAD) –approved in 2014

• How to implement BIM for information technology systems projects

• For organizations that create CAD drawings

BICSI Updates In Progress• BICSI‐002 Data Center Design & Implementation Best Practices  (estimated 2014)  updates to include new technologies, energy efficiency, modular data centers, DCIM, and extend class structure [availability levels] to architectural, mechanical, network, cabling. 

• Basis for BICSI Data Center Design Consultant (DCDC) certification and great reference for any data center owner or designer (along with TIA‐942‐A, ISO/IEC 24764, or local standard)

BICSI Updates In Progress• BICSI‐001 Educational Facilities ‐ a revision of BICSI‐001 to include all types of educational facilities with information on a wide range of special systems and considerations 

• Estimated publication 2015

BICSI Updates In Progress• BICSI 012 – Distributed Antenna Systems (DAS) Design & Implementation Best Practices (estimated 2015) – for designers of DAS

BICSI Updates In Progress• BICSI 013 – Outside Plant Installation –installation of  telecom cabling for outside plant (estimated completion in 2015)

• Supplements – BICSI Outside Plant Design Reference Manual (OSPDRM) by providing more implementation details

• For outside plant installers & designers

BICSI Updates In Progress

• BICSI 568 – North American Cabling Installation ‐ project being initiated to revise by 2016

• BICSI – International Cabling Installation –project being initiated and looking for volunteers to develop international cabling installation standard – see www.bicsi.org or email me

BICSI Translated Publications• ANSI/NECA/BICSI 607‐2011, Norma de planificación e instalación de la puesta a tierra y conexión equipotencial en los edificios comerciales

• ANSI/BICSI 005‐2013, Mejores prácticas para la implementación y el diseño de los sistemas de seguridad y protección electrónica (ESS)

• Others, perhaps BICSI‐002 Data Centers

Questions?Jonathan JewPresident J&M Consultants, Inc.Website: www.j‐and‐m.comEmail: jew@j‐and‐m.comCo‐chair BICSI data center subcommitteeEditor TDMM 13th Edition Telecom AdministrationChair TIA TR‐42.6 telecom administration subcommittee Vice‐Chair TIA TR‐42.1 commercial building cablingVice‐chair USTAG to ISO/IEC JTC 1 SC 25 WG 3Editor ISO/IEC TR 14763‐2‐1 telecom admin identifiersSME BICSI TI&M Telecommunications AdministrationSecretary TIA TR‐42

¡GRACIAS!