Start an Intravenous Infusion 081-T-1012-1

Upload: adela-fowler

Post on 15-Jan-2016

224 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Start an Intravenous Infusion

081-T-1012-1

Page 2: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Administering Intravenous Fluids Through a Saline Lock

081-T-1012-2

Page 3: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Obtain and Check Supplies

• Obtain the following: IV bag, IV infusion set, 18 gauge needle/catheter unit, tape

• Check IV bag for expiration date, clearness of fluid, tears, fluid leakage, and contamination

081-T-1012-3

Page 4: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Prepare the Intravenous Infusion 1

• Remove infusion set from package

• Loosen the clamp, move the clamp along the tubing until it is 6 to 8 inches from the drip chamber, and tighten clamp

OPEN CLOSED081-T-1012-4

Page 5: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Prepare the Intravenous Infusion 2

• Remove protective covering from outlet port (long spout) on IV bag

• Remove protective cap from the spike on the infusion set without touching the spike

• Insert spike into exposed IV outlet port with a twisting motion

IV Tubing Port

Medication Port081-T-1012-5

Page 6: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Prepare the Intravenous Infusion 3

• Squeeze the drip chamber until half of the chamber is filled with IV solution

081-T-1012-6

Page 7: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Prepare the Intravenous Infusion 4

Remove air from the tubing by:

• Holding the end of the tubing above the bottom of the bag

• Loosening the tubing clamp to allow fluid into the tubing

• Loosening protective cap on adapter to allow air to escape from tubing

• Gradually lowering tubing until fluid reaches end of adapter

• Reclamping the tubing and retightening the adapter cap

081-T-1012-7

Page 8: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Insert Catheter/Needle 1

• Remove 18-gauge catheter/needle unit from package

• Hold catheter/needle unit in dominant hand and stabilize the saline lock adapter with thumb and forefinger of nondominant hand

• Insert catheter needle unit through Tegaderm dressing and saline lock adapter until it reaches catheter hub

081-T-1012-8

Page 9: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Insert Catheter/Needle 2

• Remove nondominant hand from saline lock, place finger/thumb of nondominant hand over vein just beyond the catheter tip, and apply pressure to vein

• Retract and discard needle (catheter stays in place)

081-T-1012-9

Page 10: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Connect IV Tubing

• Grasp end of IV tubing with dominant hand and remove adapter from tubing

• Grasp the hub of the catheter (outside Tegaderm dressing) with thumb and forefinger of nondominant hand

• Insert end of tubing into hub of catheter

081-T-1012-10

Page 11: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Adjust Flow and Secure Tubing 1

• Loosen clamp on tubing (about ½ way) to allow IV solution to flow into drip chamber

• Unroll about 2 inches of tape

• Place tape (sticky side up) on casualty’s limb and under IV tubing a few inches beyond catheter hub and beyond Tegaderm dressing

081-T-1012-11

Page 12: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Adjust Flow and Secure Tubing 2

• Fold tape strip back over tubing, trapping tubing between sticky sides of tape

• Wrap additional tape around limb and IV tubing distal to first

• Ensure tubing is secure and IV flow is not impeded

• Check infusion site for signs of infiltration

081-T-1012-12

Page 13: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Signs of Infiltration

• Unusual pain at infusion site

• Swelling or redness at infusion site

• Infusion site is cool to the touch

• Clear fluid leaking around the site

081-T-1012-13

Page 14: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Discontinue the IV 1

• Due to evacuation

• IV fluid has been used up

• Infiltration

• Other reasons

081-T-1012-14

Page 15: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Discontinue the IV 2

• Adjust clamp on tubing so flow is stopped

• Loosen and remove tape

• Remove IV catheter hub that is outside Tegaderm dressing

• Saline lock adapter may remain in place for later use

081-T-1012-15

Page 16: Start an Intravenous Infusion 081-T-1012-1. Administering Intravenous Fluids Through a Saline Lock 081-T-1012-2

Remove Catheter from Vein

• Grasp catheter hub and remove catheter from vein at an angle almost parallel to skin

• Cover puncture site with gauze dressing and hold pressure until bleeding stops

• Tape dressing in place