start exit 1 cladding. start exit 2 outline product range features cost-effectiveness insulation...

26
1 Start Exit Cladding

Upload: adrian-coleman

Post on 26-Mar-2015

223 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

1Start Exit

Cladding

Page 2: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

2Start Exit

OutlineProduct RangeFeaturesCost-EffectivenessInsulationSelekta Profile

Laying Methods

Technical Specifications

Assembly Instructions

Siding ProfileLaying Methods

Technical Specifications

Assembly Instructions

ColoursReference Projects

Cladding: Outline

Cladding

Page 3: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

3Start Exit

Cladding | Product Range

Selekta Siding

Cladding: Products

Page 4: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

4Start Exit

Wood cladding

Werzalit Colorpan

100 % processable

Approx. 10 % wastedue to warping/knots

Ready to fit incl.factory-coated surface

Surface finishrequired

100 % maintenance-freewith warranty certificate

Coat approx. every 4 years

Cladding | Cost-Effectiveness

Cladding: Cost-Effectiveness

Price/Euro Grade Width shrinkage Surface finish Maintenance interval 1 Maintenance interval 2 Maintenance interval 3

69

46

15

Page 5: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

6Start Exit

Selekta FeaturesOption of horizontal, vertical or diagonal installation

Large fixing clearances up tomax. 625 mm

Ready-to-fit tongue-and-groove joints

Pre-punched slots for fixing cladding screws 3.5 mm x 30 mm

Can also be used as weatherboarding in conjunction with T+G weatherboarding hooks

Matching profiles, universal connecting profiles and soffit/fascia profiles available

Cladding | Selekta Features

Horizontal Vertical Diagonal

Cladding: Features

Page 6: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

8Start Exit

Technical Specifications

Cladding | Selekta Technical Specifications

Cladding profile Selekta 155/1 Selekta 115/1

Coverage width 155 mm (+1/-2) 115 mm (+1/-2)

Coverage length 5400 mm max. 5400 mm max.

Material requirement/sq m 6.45 running m 8.7 running m

Thickness when fitted approx. 19 mm approx. 19 mm

Versions B2*, B1** B2*

Surface Crepe texture, colours: colorpan/dekopan plus

* Standard - normal flammability** On request - low flammability

Cladding: Technical Specifications

Page 7: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

9Start Exit

Cladding | Selekta Fittings System

Cladding: Fittings System

Start of installation: Horizontal Vertical

Page 8: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

10Start Exit

Cladding | Selekta Fittings System

Cladding: Fittings System

Connection at window parapet with Z profile 2

Page 9: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

11Start Exit

Cladding | Selekta Fittings System

Cladding: Fittings System

Connection at window reveal with externalcorner C or connecting profile F

Page 10: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

12Start Exit

Internal corner transition with joint tape 2

Cladding | Siding Fittings System

Cladding: Fittings System

Page 11: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

13Start Exit

Cladding | Selekta Fittings System

Cladding: Fittings System

Connection at window lintel with Z profile 1

Page 12: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

14Start Exit

Cladding | Selekta Fittings System

Cladding: Fittings System

Corner solution with external corner C

Page 13: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

15Start Exit

Siding FeaturesHorizontal installation

Butt joint prefabricated and incorporated in profile: overlapping, no open joints

Large fixing clearances possible up to max.625 mm (distance of support battens)

Ready-to-fit tongue-and-groove joints in weatherboarding effect

Pre-punched slots for fixing cladding screws 3.5 mm x 30 mm

Handy profile length (3.66 m) can be fitted by one person

Matching profiles available

Cladding | Siding Features

Horizontal

Cladding: Siding Features

Butt joint

Page 14: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

16Start Exit

Technical Specifications

Cladding | Siding Technical Specifications

Cladding profile Siding 152

Coverage width 152 mm (+/-1)

Coverage length max. 3600 mm (+2/-1)

Material requirement/sq m 6.58 running m

Thickness when fitted approx. 20 mm (fitted), 10 mm (tongue), 18 mm (groove)

Versions B2*, B1**

Surface Flat texture, colours: colorpan

* Standard - normal flammability** On request - low flammability

Cladding: Technical Specifications

Page 15: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

17Start Exit

Start of installation with starter profile P

Cladding | Siding Fittings System

Cladding: Fittings System

Page 16: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

18Start Exit

Window parapet with Z profile 2

Cladding | Siding Fittings System

Cladding: Fittings System

Page 17: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

19Start Exit

Cladding | Siding Fittings System

Cladding: Fittings System

Connection at window reveal with externalcorner C or connecting profile F

Page 18: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

20Start Exit

Connection at window lintel with Z profile 1

Cladding | Siding Fittings System

Cladding: Fittings System

Page 19: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

21Start Exit

External corner Outside profile C with base section and cover

Cladding | Siding Fittings System

Cladding: Fittings System

Alternatively: Werzalit S 145 profile

Page 20: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

22Start Exit

Selekta colour chartSiding colour chart

Cladding | Colours & Designs

Cladding: Colours & Designs

Page 21: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

23Start Exit

Cladding | Before/After

Cladding: Before/After

Page 22: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

24Start Exit

Cladding | Reference Projects

Cladding: Reference Projects

Page 23: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

25Start Exit

Cladding | Reference Projects

Cladding: Reference Projects

Page 24: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

26Start Exit

Cladding | Reference Projects

Cladding: Reference Projects

Page 25: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

27Start Exit

Cladding | Reference Projects

Cladding: Reference Projects

Page 26: Start Exit 1 Cladding. Start Exit 2 Outline Product Range Features Cost-Effectiveness Insulation Selekta Profile Laying Methods Technical Specifications

28Start Exit

Cladding | Reference Projects

Cladding: Reference Projects