static o ring glands

1
Static O - Ring Glands © 2014, RT Dygert, Inc. L E(a) R Max O-Ring Gland Diametral No Back-Up One Back-Up Two Back-Up Groove Eccentricity AS568- Nominal Actual Depth Actual % Clearance Ring(G) Ring (G 1 ) Ring (G 2 ) Radium (b) 004 through 050 1/16 .070 ± 003 .050 to .052 .015 to .023 22 to 32 .002 to .005 .093 to .098 .138 to .143 .205 to .210 .005 to .015 .002 102 through 178 3/32 .103 ± 003 .081 to .083 .017 to .025 17 to 24 .002 to .005 .140 to .145 .171 to .176 .238 to .243 .005 to .015 .002 201 through 284 1/8 .139 ± 004 .111 to .113 .022 to .032 16 to 23 .003 to .006 .187 to .192 .208 to .213 .275 to .280 .010 to .025 .003 309 through 395 3/16 .210 ± 005 .170 to .173 .032 to .045 15 to 21 .003 to .006 .281 to .286 .311 to .316 .410 to .415 .020 to .035 .004 425 through 475 1/4 .275 ± 006 .226 to .229 .040 to .055 15 to 20 .004 to .007 .375 to .380 .408 to .413 .538 to .543 .020 to .035 .005 W Cross Section Squeeze G-Groove Width (a) Clearance (extrusion gap) must be held to a minimum consistent with design requirements for temperature range variation. (b) Total indicator reading between groove and adjacent bearing surface. (c) Reduce maximum diametral clearance 50% when using silicone or fluorosilicone O-Rings. (d) For ease of assembly, when Back-Ups are used, gland depth may be increased up to 5%. Male Gland B-1 Dia. (B-1 Min.=A Max.-2 L Max.) C Dia. A Dia. 1/2E 1/2E B Dia. D Dia. A-1 Dia. (A-1 Max.=B Min. + 2L Max.) Female Gland 0° to 5° (Typ.) Gland Detail Finishes are RMS values Break Corners Approx. 005RAD. .005 Typ. Pressure G No Back-Up Ring Pressure G1 One Back-Up Ring Pressure G2 Two Back-Up Rings .003 Typ. F Groove Depth (Ref.) Section W-W 32 R G F L 32 63 63 1/2E W W W W Gland Depth LD. CHICAGO 2700 S. River Road, Suite 116 Des Plaines, IL 60018 847.675.1444 PHONE PHONE 800.423.9272 TOLL FREE TOLL FREE 847.675.8889 FAX FAX SEATTLE 3902 W. Valley Hwy N., Suite 200 Auburn, WA 98001 253.218.0123 PHONE PHONE 877.796.0123 TOLL FREE TOLL FREE 253.218.0121 FAX FAX MINNEAPOLIS 12121 Nicollet Avenue S. Burnsville, MN 55337 952.835.1700 PHONE PHONE 866.783.8883 TOLL FREE TOLL FREE 952.835.1701 FAX FAX sales@rtdygert.com www.rtdygert.com

Upload: rtdygert

Post on 11-Apr-2017

52 views

Category:

Engineering


0 download

TRANSCRIPT

Page 1: Static O Ring Glands

Static O-Ring Glands

© 2014, RT Dygert, Inc.

L E(a) R Max O-Ring Gland Diametral No Back-Up One Back-Up Two Back-Up Groove Eccentricity AS568- Nominal Actual Depth Actual % Clearance Ring(G) Ring (G1) Ring (G2) Radium (b)

004 through 050 1/16 .070 ± 003 .050 to .052 .015 to .023 22 to 32 .002 to .005 .093 to .098 .138 to .143 .205 to .210 .005 to .015 .002 102 through 178 3/32 .103 ± 003 .081 to .083 .017 to .025 17 to 24 .002 to .005 .140 to .145 .171 to .176 .238 to .243 .005 to .015 .002 201 through 284 1/8 .139 ± 004 .111 to .113 .022 to .032 16 to 23 .003 to .006 .187 to .192 .208 to .213 .275 to .280 .010 to .025 .003 309 through 395 3/16 .210 ± 005 .170 to .173 .032 to .045 15 to 21 .003 to .006 .281 to .286 .311 to .316 .410 to .415 .020 to .035 .004 425 through 475 1/4 .275 ± 006 .226 to .229 .040 to .055 15 to 20 .004 to .007 .375 to .380 .408 to .413 .538 to .543 .020 to .035 .005

W Cross Section Squeeze G-Groove Width

(a) Clearance (extrusion gap) must be held to a minimum consistent with design requirements for temperature range variation.(b) Total indicator reading between groove and adjacent bearing surface.(c) Reduce maximum diametral clearance 50% when using silicone or fl uorosilicone O-Rings.(d) For ease of assembly, when Back-Ups are used, gland depth may be increased up to 5%.

Male Gland

B-1 Dia. (B-1 Min.=A Max.-2 L Max.)C Dia.A Dia.

1/2E1/2E

B Dia. D Dia. A-1 Dia.(A-1 Max.=B Min. + 2L Max.)

Female Gland

0° to 5°(Typ.)

Gland Detail

Finishes are RMS values

Break CornersApprox. 005RAD.

.005 Typ. Pressure

GNo

Back-Up Ring

Pressure

G1

OneBack-Up Ring

Pressure

G2

TwoBack-Up Rings

.003 Typ.

F GrooveDepth (Ref.)

Section W-W

32

R

G

F L32

63

63

1/2E W

W

W

WGlandDepth LD.

CHICAGO2700 S. River Road, Suite 116

Des Plaines, IL 60018

847.675.1444 PHONEPHONE

800.423.9272 TOLL FREETOLL FREE

847.675.8889 FAXFAX

SEATTLE3902 W. Valley Hwy N., Suite 200

Auburn, WA 98001

253.218.0123 PHONEPHONE

877.796.0123 TOLL FREETOLL FREE

253.218.0121 FAXFAX

MINNEAPOLIS12121 Nicollet Avenue S.

Burnsville, MN 55337

952.835.1700 PHONEPHONE

866.783.8883 TOLL FREETOLL FREE

952.835.1701 FAXFAX

[email protected] • www.rtdygert.com