steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick...

14

Upload: others

Post on 03-Jun-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 2: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 3: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 4: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 5: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 6: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 7: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 8: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 9: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 10: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond
Page 11: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond

BOUNDARY 45.52m

SCALE 1:200SITE PLAN

FOOTPRINT OF DWELLINGSHOWN DASHED

FIRE-DAMAGED UNITSTO BE REPLACED

BOUNDARY 45.52mB

OU

ND

AR

Y 2

0.1

2m

BO

UN

DA

RY

20.1

2m

concrete driveway

laneway

exte

rnal

stai

rcas

e

MUS

T STR

EET

SITE DETAILS:

RP: 15168VOLUME: 4399FOLIO: 666ALLOTMENT: 54SECTION: DSITE AREA: 916m2

DWELLING FOOTPRINT: 140m2

LOCAL GOVERNMENT AUTHORITY: PORTLAND COUNCIL

EXISTING UNDAMAGED UNITS

4400 (C.O.S)3560 (C.O.S)

fenc

e

fenc

e

fence

fence

fenc

e

lattice fence

colo

rbon

d fe

nce

2510

(C.O

.S)

concrete path

conc

rete

pat

h

gravel

concrete

concreteVERANDAHVERANDAH

ADJACENTBUILDING

garden bed

DESCRIPTIONREVISION DATE

SCALE :

DESIGN :

DRAWN :

DATE :

FILE REF :

DWG NO :

AT

REV No :

OFSHEET SIZETHIS DRAWING SHALL NOT BE USED OR RELIED UPON BY PARTIES OTHER THAN THENAMED CLIENT, AND/OR THEIR APPOINTED BUILDERS AND SUB-CONTRACTORS.DRAWINGS ARE NOT TO BE SCALED. ALL WRITTEN DIMENSIONS AND LEVELS ARE TOBE VERIFIED ON SITE PRIOR TO THE ORDER OF MATERIALS AND CONSTRUCTION.

ADELAIDE P: +61 8 8150 5500

SYDNEY

BRISBANE

HOBART

MELBOURNE

P: +61 7 3844 8440

P: +61 3 9036 3079

P: +61 3 9036 3079

P: +61 2 9509 0700

impartaengineers.com.au

ABN: 58 086 672 915

W:Mountford Prider Pty Ltd

CLIENT:C/-REF No: I/O:

REPLACEMENT OF FIRE-DAMAGED UNITS

98 Must StreetPORTLAND VIC 3305

SITE PLAN1:200

STL

GTH

23-12-2017

0760917STL

D3

A

26A3

Strata Unit Underwriting Agency Pty LtdCunningham Lindsey Australia Pty Ltd03015168 18092017 OC015168

NO

RTH

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE SCOPE OF WORKS

ABBREVIATIONS

SYMBOL DESCRIPTION

cos CHECK ON SITE

tme TO MATCH EXISTING

uno UNLESS NOTED OTHERWISE

tbc TO BE CONFIRMED

℄ CENTRE LINE

⅊ PLATE

BOUNDARY LINE

dp DOWNPIPE

vp VENTPIPE

cj CONTROL JOINT

TBM TEMPORARY BENCH MARK

FL FLOOR LEVEL

FFL FINISHED FLOOR LEVEL

CL CEILING LEVEL

RL RELATIVE LEVEL

AFL ABOVE FLOOR LEVEL

ABL ABOVE BENCH LEVEL

FRL FIRE RESISTANCE LEVEL

0 2 4 6 8 10m

REV. A ISSUE TO CLIENT 23-12-2017

Page 12: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond

SCALE 1:100GROUND FLOOR PLAN

110

SSLOUNGE

BED 1

BED 2

L'DRYWC KITCHEN

LOUNGE

BED 1

BED 2

L'DRY WCKITCHEN

2703040

1103035

2703035

1103040

270

270

1007

027

0

270

3925

110

3300

110

2625

270

1007

027

0

270

3925

110

3300

110

2625

270

2702720

1103355

2703355

1102720

270

270900

902430 2655

2702655

1101060

902270

270

B.I.R

B.I.R

06.06 09.85 10.15 10.15 09.85 06.06

20.1

8 20.2

4

20.21 20.2120.18 20.18

S

LEGEND

HARDWIRED SMOKE ALARM WITH BATTERY BACK-UPdp DOWNPIPEfw FLOOR WASTEgt GARDEN TAP

FLOOR COVERING LEGEND

c - CARPETff - FLOATING FLOORct - CERAMIC TILE

UNIT 5UNIT 4

13180

FIRE

SEP

ARA

TION

WA

LL

c

ct

ct

ctffct

ff

c

c

c

c

D4.5

D4.6

D4.4 D5.4

D5.5

D5.6

D5.

1

D4.

1D

4.2

D5.

2

D4.

3 D5.

3

VERANDAHVERANDAH

3600

2300

4400

1300

LANDING/BALCONYOVER

dpdp

dpdp

1061

0

dp

dp

AD14

AD14

1800 h WALL

REAR VERANDAHS

REAR VERANDAH SEPARATION SHALL COMPLY WITH BCAVOLUME 2 CLAUSE 3.7.1.

THERMAL INSULATION

REFER TO ENERGY ASSESSMENT REPORTS PREPARED BYGREENRATE.

NOTE: FOIL BOARD TO BE INSTALLED IN CAVITY MASONRYEXTERNAL WALLS

ACOUSTIC INSULATION

IN ACCORDANCE WITH BCA 2016 PART F5 SOUND TRANSMISSIONAND INSULATION

SEPARATING WALLSACHIEVE AN Rw + Ctr (AIRBORNE)OF NOT LESS THAN 50

CEILING AND FLOORSACHIEVE AN RW + CTR (AIRBORNE)OF NOT LESS THAN 50ACHIEVE AN Ln,w (IMPACT) NOT MORE THAN 62.

SERVICES IN WALLS AND CEILINGWRAP WATER, WASTE AND SEWER PIPE WITH ADDITIONACOUSTIC INSULATION TO ACHIEVE Rw +Ctr (AIRBORNE)OF NOT LESS 40.

SECURE WATER SUPPLY PIPE AS NEEDED TO PREVENT WATERHAMMER. INSTALL TAPS AND THE LIKE WITH DAMPERS AS NEEDED.

REFER DETAILDWG. D16(TYPICAL)

GENERAL FINISHES

UNIT 4

CEILINGS - FLUSHED PLASTERBOARDCORNICE - 55mm COVE CORNICE

WALLSSHEET LINED MASONRY WALLS PLASTERBOARDGENERALLY, FRC TO WET AREAS

DOORS INTERNAL PAINTED FLUSH PANEL HOLLOW COREEXTERNAL PAINTED FLUSH PANEL SOLID CORECAVITY SLIDER TO WCPOWDERCOATED SECURITY SCREEN DOORS TOEXTERNAL DOOR OPENINGS

WINDOWSPOWDERCOATED ALUMINIUM WITH FLYSCREEN

SKIRTING BOARD 90X19 SINGLE BEVELARCHITRAVES METAL DOOR JAMB WITH

42X19 SINGLE BEVEL ARCHITRAVES

BUILT IN ROBES TO BED 1 AND 21800X600 MELAMINE SHELVES AND FRAME, HANDINGRAIL. 2 FOUR-PANEL SLIDING DOORS

UNIT 5

CEILINGS - FLUSHED PLASTERBOARDCORNICE - 55MM COVE CORNICE

WALLSALL FACEBRICK INTERNAL WALLS EXCEPT AS NOTEDPAINTED FACE BRICK/FRC (pfb).PLASTERBOARD LINING TO SEPARATING WALL TOCOVER TIE DOWN STRAPS.

DOORSINTERNAL CLEAR TIMBER VENEER HOLLOW CORESLIDER TO WET AREAEXTERNAL PAINTED FLUSH PANEL SOLID COREPOWDERCOATED SECURITY SCREEN DOORS TOEXTERNAL DOOR OPENINGS

WINDOWSPOWDERCOATED ALUMINIUM WITH FLYSCREEN

SKIRTING BOARDS - NIL GENERALLY. HOWEVERINSTALL ALONG SEPARATINGWALL WHERE LINED WITHPLASTERBOARD

ARCHITRAVES - METAL DOOR JAMB

pfb

pfb

pfbpfbfw fw

gt

PREVIOUS HWSLOCATION INCUPBOARD.OWNER WANTSTO REINSTATEHWSEXTERNALLY

cupcup

cup

STEEL TROUGHAND CABINET

PASS

AG

E

13180

fwfw

SMOKE ALARM TOUNIT 5 BEDROOM 2

SHALL BEINTERCONNECTEDWITH UNIT 6 ENTRY

SMOKE ALARM

Spb

4750

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

UP

hand

rail

hand

rail

30 SET DOWN, 50 TOSHOWER

30 SET DOWN,50 TO SHOWER

FL100.161

FL100.00

DESCRIPTIONREVISION DATE

SCALE :

DESIGN :

DRAWN :

DATE :

FILE REF :

DWG NO :

AT

REV No :

OFSHEET SIZETHIS DRAWING SHALL NOT BE USED OR RELIED UPON BY PARTIES OTHER THAN THENAMED CLIENT, AND/OR THEIR APPOINTED BUILDERS AND SUB-CONTRACTORS.DRAWINGS ARE NOT TO BE SCALED. ALL WRITTEN DIMENSIONS AND LEVELS ARE TOBE VERIFIED ON SITE PRIOR TO THE ORDER OF MATERIALS AND CONSTRUCTION.

ADELAIDE P: +61 8 8150 5500

SYDNEY

BRISBANE

HOBART

MELBOURNE

P: +61 7 3844 8440

P: +61 3 9036 3079

P: +61 3 9036 3079

P: +61 2 9509 0700

impartaengineers.com.au

ABN: 58 086 672 915

W:Mountford Prider Pty Ltd

CLIENT:C/-REF No: I/O:

REPLACEMENT OF FIRE-DAMAGED UNITS

98 Must StreetPORTLAND VIC 3305

GROUND FLOOR PLAN1:100

STL

GTH

23-12-2017

0760917STL

D5

A

26A3

Strata Unit Underwriting Agency Pty LtdCunningham Lindsey Australia Pty Ltd03015168 18092017 OC015168

NO

RTH

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE SCOPE OF WORKS

0 1 2 3 4 5m

REV. A ISSUE TO CLIENT 23-12-2017

Page 13: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond

SCALE 1:100UNIT 6 FIRST FLOOR PLAN

3450

LOUNGE

KITCHEN

BED 2

BED 3

BATHWC

LAUNDRY

ENTRY

ENSUITE

BED 1

392590

288090

127590 250

LINENB.I.R

B.I.C

2501755

903880

2501755

904480

90900

902085

903100

250

2504175

90 907570

250

2505020

907570

250

4930

9022

5090

2750

250

250

3020

9030

0090

3910

250

61090

3300

250

250

5710

9014

7090

2750

250

S

250

250

1005

B.I.R

600

90790

1500arch

1000

1061

0

B.I.R

06.06 09.85

10.1

2

20.1

8

20.21 20.2110.15

06.2

7

20.21

09.1

2

AD14

AD14

S

UNIT 6c

D6.9

c

cct

ctct

ct

ct

ff

1400

DOWN

6710

1000

HIG

H BA

LUST

RAD

E

BALC

ON

Y

dp dp

dpdp

D6.1D6.3

D6.

5

D6.

4

D6.

6

D6.

7

D6.

10

D6.2

D6.8c

S

LEGEND

HARDWIRED SMOKE ALARM WITH BATTERY BACK-UPDOWNPIPEFLOOR WASTE

FLOOR COVERING LEGEND

c - CARPETff - FLOATING FLOORct - CERAMIC TILE

13180

fwfw fw

fwdp

GENERAL FINISHES

UNIT 6

CEILINGS - FLUSHED PLASTERBOARDCORNICE - 55mm COVE CORNICE

WALLSFLUSHED PLASTERBOARD GENERALLY , FRC TO WET AREAS

DOORS INTERNAL PAINTED FLUSH PANEL HOLLOW CORESLIDER TO LAUNDRYEXTERNAL PAINTED FLUSH PANEL SOLID COREPOWDERCOATED SECURITY SCREEN DOORS TO EXTERNAL DOOR OPENINGS

WINDOWSPOWDERCOATED ALUMINIUM WITH FLYSCREEN

SKIRTING BOARD 90X19 SINGLE BEVELARCHITRAVES 42X19 SINGLE BEVEL

JOINERY

BED 11800X600 BUILT IN ROBE, MELAMINE FRAME AND SHELVES, HANGING RAIL2 SLIDING FLUSH PANEL DOORS

BED 2

1735X600 BUILT IN ROBE, MELAMINE FRAME AND SHELVES, HANGING RAIL2 SLIDING FLUSH PANEL DOORS. MEASURE ALCOVE ON SITE BEFOREMANUFACTURE

BEDROOM 3

2730X600 BUILT IN ROBE, MELAMINE FRAME AND SHELVES, HANGING RAIL2 SLIDING FLUSH PANEL DOORS. MEASURE ALCOVE ON SITE BEFOREMANUFACTURE

LINEN

1275X470 MELAMINE FRAME AND SHELVING, MELAMINE HINGED DOORS.MEASURE ALCOVE BEFORE MANUFACTURE.

SET DOWN WET AREAS - 45mm

w/m

rf

'P' TRAP WC 'P' TRAP WC

HWS IN CUPBOARD. PROVIDE TUNDISH FORPRESSURE RELIEF VALVE DISCHARGE.

fallfw

PASSAGE

PROPRIETARY WEBFORGE GALVANISED STAIRCASE, BALUSTRADE AND HANDRAIL. USINGPROFILED GALVANISED CHECKER PLATETREADS AND LANDING

STAIRCASE, BALCONY AND LANDING SHALLBE IN ACCORDANCE WITH THE NCCD2.13 GOINGS AND RISERSD2.14 - LANDINGSD2.16 BARRIERS TO PREVENT FALLSD2.17 HANDRAILS

1400

4750

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

100

step

dow

n

SMOKE ALARM TOUNIT 5 BEDROOM 2

SHALL BEINTERCONNECTEDWITH UNIT 6 ENTRY

SMOKE ALARM

150

150

FL103.318

DESCRIPTIONREVISION DATE

SCALE :

DESIGN :

DRAWN :

DATE :

FILE REF :

DWG NO :

AT

REV No :

OFSHEET SIZETHIS DRAWING SHALL NOT BE USED OR RELIED UPON BY PARTIES OTHER THAN THENAMED CLIENT, AND/OR THEIR APPOINTED BUILDERS AND SUB-CONTRACTORS.DRAWINGS ARE NOT TO BE SCALED. ALL WRITTEN DIMENSIONS AND LEVELS ARE TOBE VERIFIED ON SITE PRIOR TO THE ORDER OF MATERIALS AND CONSTRUCTION.

ADELAIDE P: +61 8 8150 5500

SYDNEY

BRISBANE

HOBART

MELBOURNE

P: +61 7 3844 8440

P: +61 3 9036 3079

P: +61 3 9036 3079

P: +61 2 9509 0700

impartaengineers.com.au

ABN: 58 086 672 915

W:Mountford Prider Pty Ltd

CLIENT:C/-REF No: I/O:

REPLACEMENT OF FIRE-DAMAGED UNITS

98 Must StreetPORTLAND VIC 3305

FIRST FLOOR PLAN1:100

STL

GTH

23-12-2017

0760917STL

D6

A

26A3

Strata Unit Underwriting Agency Pty LtdCunningham Lindsey Australia Pty Ltd03015168 18092017 OC015168

NO

RTH

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE SCOPE OF WORKS

0 1 2 3 4 5m

REV. A ISSUE TO CLIENT 23-12-2017

Page 14: steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick masonry to external wall to owner's selection entry staircase pvc downpipes colorbond

SCALE 1:100EAST ELEVATION

SCALE 1:100SOUTH ELEVATION

SCALE 1:100NORTH ELEVATION

SCALE 1:100WEST ELEVATION

STEEL ROOF SHEETINGTO CORROSIONENVIRONMENT

COLORBONDGUTTERS WITH OVERFLOW PROTECTION

FACEBRICKMASONRY TOEXTERNAL WALL TOOWNER'S SELECTION

ENTRY STAIRCASE

PVC DOWNPIPES

COLORBOND STEEL CLADDINGINFILL. COLORBOND FLASHINGAND VERTICAL EDGESSOLID EXTERNAL DOORS (TYPICAL)

2450

CL

FL

FL

2693

2450

CL

FL

FL

VERANDAH STRUCTURESSHOWN DASHED

UNIT 5UNIT 4

UNIT 4UNIT 5

UNIT 5

UNIT 6UNIT 6

UNIT 5

UNIT 6

UNIT 4

UNIT 6UNIT 6

POWDERCOATED SECURITY SCREEN DOORPOWDERCOATED SECURITYSCREEN DOOR

HOT WATER SERVICE ONCONCRETE PAD

PROPOSED HOTWATER SERVICE ON

CONCRETE PAD

POLYCARBONATEROOF DECK TOVERANDAHS

DUCTED EXHAUSTFAN, SELF CLOSINGDAMPER (TYPICAL)

GALVANISED HANDRAIL, BALUSTRADE,TREADS, LANDING AND FRAME.

VERTICAL BALUSTERS. GAPS SHALL NOTPERMIT THE PASSING THROUGH OF A

125mm SPHERE

OBSCURED GLAZING TO WETAREA WINDOWS (TYPICAL)

UPPER STOREY WINDOWS TO BEFITTED WITH A DEVICE TO LIMIT THEOPENING OR A SUITABLE SCREEN SOAS 125mm SPHERE CANNOT PASSTHROUGH.

BARGE CAP

10mm FOIL BOARD TO BE INSTALLEDTO EXTERNAL CAVITY MASONRYWALLS

LOUNGE WINDOW,SILL TO BE LOCATED1.5M ABOVE FLOOR

LEVEL INACCORDANCE WITH

CLAUSE C3.11(g)(v)(B)

2453

U/S OFFLOORFRAME

2693

2453

U/S OFFLOORFRAME

CL

CL

1500

1000

UNIT 6 ELECTRICAL SUPPLYIN CONDUIT BROUGHT UPEXTERNAL FACE OF WALL

METER BOXES

METER BOX

DENOTES EXTENT OF BEDJOINT LADDERREINFORCEMENT. REFER TO DRAWING D12FOR ADDITIONAL DETAIL. DO NOT CONTINUETHROUGH MASONRY CONTROL JOINTS

PROPRIETARYSTEELFRAMEDVERANDAH

GALVANISED VENTILATION'BRICK' (TYPICAL) ATFLOOR/CEILING SPACE

GALVANISED VENTS (TYPICAL)

RENDERED, PAINTED FRC BALCONY BALUSTRADE,COLORBOND CAP. 70mm GAP AT BOTTOM EDGEFOR DRAINAGE OF TILE DECK

EXTERNAL SEWER STACKS ANDVENTPIPES NOT SHOWN.

DENOTES FIRE RATED MINERAL FIBRE WOOLCAVITY BARRIER LOCATION

aj aj

ajajaj

aj

aj

ajaj

aj - ARTICULATION JOINT

DESCRIPTIONREVISION DATE

SCALE :

DESIGN :

DRAWN :

DATE :

FILE REF :

DWG NO :

AT

REV No :

OFSHEET SIZETHIS DRAWING SHALL NOT BE USED OR RELIED UPON BY PARTIES OTHER THAN THENAMED CLIENT, AND/OR THEIR APPOINTED BUILDERS AND SUB-CONTRACTORS.DRAWINGS ARE NOT TO BE SCALED. ALL WRITTEN DIMENSIONS AND LEVELS ARE TOBE VERIFIED ON SITE PRIOR TO THE ORDER OF MATERIALS AND CONSTRUCTION.

ADELAIDE P: +61 8 8150 5500

SYDNEY

BRISBANE

HOBART

MELBOURNE

P: +61 7 3844 8440

P: +61 3 9036 3079

P: +61 3 9036 3079

P: +61 2 9509 0700

impartaengineers.com.au

ABN: 58 086 672 915

W:Mountford Prider Pty Ltd

CLIENT:C/-REF No: I/O:

REPLACEMENT OF FIRE-DAMAGED UNITS

98 Must StreetPORTLAND VIC 3305

ELEVATIONS1:100

STL

GTH

23-12-2017

0760917STL

D7

A

26A3

Strata Unit Underwriting Agency Pty LtdCunningham Lindsey Australia Pty Ltd03015168 18092017 OC015168

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE SCOPE OF WORKS

0 1 2 3 4 5m

REV. A ISSUE TO CLIENT 23-12-2017