steel roof sheeting to corrosion environment colorbond gutters with over flow protection facebrick...
TRANSCRIPT
BOUNDARY 45.52m
SCALE 1:200SITE PLAN
FOOTPRINT OF DWELLINGSHOWN DASHED
FIRE-DAMAGED UNITSTO BE REPLACED
BOUNDARY 45.52mB
OU
ND
AR
Y 2
0.1
2m
BO
UN
DA
RY
20.1
2m
concrete driveway
laneway
exte
rnal
stai
rcas
e
MUS
T STR
EET
SITE DETAILS:
RP: 15168VOLUME: 4399FOLIO: 666ALLOTMENT: 54SECTION: DSITE AREA: 916m2
DWELLING FOOTPRINT: 140m2
LOCAL GOVERNMENT AUTHORITY: PORTLAND COUNCIL
EXISTING UNDAMAGED UNITS
4400 (C.O.S)3560 (C.O.S)
fenc
e
fenc
e
fence
fence
fenc
e
lattice fence
colo
rbon
d fe
nce
2510
(C.O
.S)
concrete path
conc
rete
pat
h
gravel
concrete
concreteVERANDAHVERANDAH
ADJACENTBUILDING
garden bed
DESCRIPTIONREVISION DATE
SCALE :
DESIGN :
DRAWN :
DATE :
FILE REF :
DWG NO :
AT
REV No :
OFSHEET SIZETHIS DRAWING SHALL NOT BE USED OR RELIED UPON BY PARTIES OTHER THAN THENAMED CLIENT, AND/OR THEIR APPOINTED BUILDERS AND SUB-CONTRACTORS.DRAWINGS ARE NOT TO BE SCALED. ALL WRITTEN DIMENSIONS AND LEVELS ARE TOBE VERIFIED ON SITE PRIOR TO THE ORDER OF MATERIALS AND CONSTRUCTION.
ADELAIDE P: +61 8 8150 5500
SYDNEY
BRISBANE
HOBART
MELBOURNE
P: +61 7 3844 8440
P: +61 3 9036 3079
P: +61 3 9036 3079
P: +61 2 9509 0700
impartaengineers.com.au
ABN: 58 086 672 915
W:Mountford Prider Pty Ltd
CLIENT:C/-REF No: I/O:
REPLACEMENT OF FIRE-DAMAGED UNITS
98 Must StreetPORTLAND VIC 3305
SITE PLAN1:200
STL
GTH
23-12-2017
0760917STL
D3
A
26A3
Strata Unit Underwriting Agency Pty LtdCunningham Lindsey Australia Pty Ltd03015168 18092017 OC015168
NO
RTH
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE SCOPE OF WORKS
ABBREVIATIONS
SYMBOL DESCRIPTION
cos CHECK ON SITE
tme TO MATCH EXISTING
uno UNLESS NOTED OTHERWISE
tbc TO BE CONFIRMED
℄ CENTRE LINE
⅊ PLATE
BOUNDARY LINE
dp DOWNPIPE
vp VENTPIPE
cj CONTROL JOINT
TBM TEMPORARY BENCH MARK
FL FLOOR LEVEL
FFL FINISHED FLOOR LEVEL
CL CEILING LEVEL
RL RELATIVE LEVEL
AFL ABOVE FLOOR LEVEL
ABL ABOVE BENCH LEVEL
FRL FIRE RESISTANCE LEVEL
0 2 4 6 8 10m
REV. A ISSUE TO CLIENT 23-12-2017
SCALE 1:100GROUND FLOOR PLAN
110
SSLOUNGE
BED 1
BED 2
L'DRYWC KITCHEN
LOUNGE
BED 1
BED 2
L'DRY WCKITCHEN
2703040
1103035
2703035
1103040
270
270
1007
027
0
270
3925
110
3300
110
2625
270
1007
027
0
270
3925
110
3300
110
2625
270
2702720
1103355
2703355
1102720
270
270900
902430 2655
2702655
1101060
902270
270
B.I.R
B.I.R
06.06 09.85 10.15 10.15 09.85 06.06
20.1
8 20.2
4
20.21 20.2120.18 20.18
S
LEGEND
HARDWIRED SMOKE ALARM WITH BATTERY BACK-UPdp DOWNPIPEfw FLOOR WASTEgt GARDEN TAP
FLOOR COVERING LEGEND
c - CARPETff - FLOATING FLOORct - CERAMIC TILE
UNIT 5UNIT 4
13180
FIRE
SEP
ARA
TION
WA
LL
c
ct
ct
ctffct
ff
c
c
c
c
D4.5
D4.6
D4.4 D5.4
D5.5
D5.6
D5.
1
D4.
1D
4.2
D5.
2
D4.
3 D5.
3
VERANDAHVERANDAH
3600
2300
4400
1300
LANDING/BALCONYOVER
dpdp
dpdp
1061
0
dp
dp
AD14
AD14
1800 h WALL
REAR VERANDAHS
REAR VERANDAH SEPARATION SHALL COMPLY WITH BCAVOLUME 2 CLAUSE 3.7.1.
THERMAL INSULATION
REFER TO ENERGY ASSESSMENT REPORTS PREPARED BYGREENRATE.
NOTE: FOIL BOARD TO BE INSTALLED IN CAVITY MASONRYEXTERNAL WALLS
ACOUSTIC INSULATION
IN ACCORDANCE WITH BCA 2016 PART F5 SOUND TRANSMISSIONAND INSULATION
SEPARATING WALLSACHIEVE AN Rw + Ctr (AIRBORNE)OF NOT LESS THAN 50
CEILING AND FLOORSACHIEVE AN RW + CTR (AIRBORNE)OF NOT LESS THAN 50ACHIEVE AN Ln,w (IMPACT) NOT MORE THAN 62.
SERVICES IN WALLS AND CEILINGWRAP WATER, WASTE AND SEWER PIPE WITH ADDITIONACOUSTIC INSULATION TO ACHIEVE Rw +Ctr (AIRBORNE)OF NOT LESS 40.
SECURE WATER SUPPLY PIPE AS NEEDED TO PREVENT WATERHAMMER. INSTALL TAPS AND THE LIKE WITH DAMPERS AS NEEDED.
REFER DETAILDWG. D16(TYPICAL)
GENERAL FINISHES
UNIT 4
CEILINGS - FLUSHED PLASTERBOARDCORNICE - 55mm COVE CORNICE
WALLSSHEET LINED MASONRY WALLS PLASTERBOARDGENERALLY, FRC TO WET AREAS
DOORS INTERNAL PAINTED FLUSH PANEL HOLLOW COREEXTERNAL PAINTED FLUSH PANEL SOLID CORECAVITY SLIDER TO WCPOWDERCOATED SECURITY SCREEN DOORS TOEXTERNAL DOOR OPENINGS
WINDOWSPOWDERCOATED ALUMINIUM WITH FLYSCREEN
SKIRTING BOARD 90X19 SINGLE BEVELARCHITRAVES METAL DOOR JAMB WITH
42X19 SINGLE BEVEL ARCHITRAVES
BUILT IN ROBES TO BED 1 AND 21800X600 MELAMINE SHELVES AND FRAME, HANDINGRAIL. 2 FOUR-PANEL SLIDING DOORS
UNIT 5
CEILINGS - FLUSHED PLASTERBOARDCORNICE - 55MM COVE CORNICE
WALLSALL FACEBRICK INTERNAL WALLS EXCEPT AS NOTEDPAINTED FACE BRICK/FRC (pfb).PLASTERBOARD LINING TO SEPARATING WALL TOCOVER TIE DOWN STRAPS.
DOORSINTERNAL CLEAR TIMBER VENEER HOLLOW CORESLIDER TO WET AREAEXTERNAL PAINTED FLUSH PANEL SOLID COREPOWDERCOATED SECURITY SCREEN DOORS TOEXTERNAL DOOR OPENINGS
WINDOWSPOWDERCOATED ALUMINIUM WITH FLYSCREEN
SKIRTING BOARDS - NIL GENERALLY. HOWEVERINSTALL ALONG SEPARATINGWALL WHERE LINED WITHPLASTERBOARD
ARCHITRAVES - METAL DOOR JAMB
pfb
pfb
pfbpfbfw fw
gt
PREVIOUS HWSLOCATION INCUPBOARD.OWNER WANTSTO REINSTATEHWSEXTERNALLY
cupcup
cup
STEEL TROUGHAND CABINET
PASS
AG
E
13180
fwfw
SMOKE ALARM TOUNIT 5 BEDROOM 2
SHALL BEINTERCONNECTEDWITH UNIT 6 ENTRY
SMOKE ALARM
Spb
4750
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
UP
hand
rail
hand
rail
30 SET DOWN, 50 TOSHOWER
30 SET DOWN,50 TO SHOWER
FL100.161
FL100.00
DESCRIPTIONREVISION DATE
SCALE :
DESIGN :
DRAWN :
DATE :
FILE REF :
DWG NO :
AT
REV No :
OFSHEET SIZETHIS DRAWING SHALL NOT BE USED OR RELIED UPON BY PARTIES OTHER THAN THENAMED CLIENT, AND/OR THEIR APPOINTED BUILDERS AND SUB-CONTRACTORS.DRAWINGS ARE NOT TO BE SCALED. ALL WRITTEN DIMENSIONS AND LEVELS ARE TOBE VERIFIED ON SITE PRIOR TO THE ORDER OF MATERIALS AND CONSTRUCTION.
ADELAIDE P: +61 8 8150 5500
SYDNEY
BRISBANE
HOBART
MELBOURNE
P: +61 7 3844 8440
P: +61 3 9036 3079
P: +61 3 9036 3079
P: +61 2 9509 0700
impartaengineers.com.au
ABN: 58 086 672 915
W:Mountford Prider Pty Ltd
CLIENT:C/-REF No: I/O:
REPLACEMENT OF FIRE-DAMAGED UNITS
98 Must StreetPORTLAND VIC 3305
GROUND FLOOR PLAN1:100
STL
GTH
23-12-2017
0760917STL
D5
A
26A3
Strata Unit Underwriting Agency Pty LtdCunningham Lindsey Australia Pty Ltd03015168 18092017 OC015168
NO
RTH
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE SCOPE OF WORKS
0 1 2 3 4 5m
REV. A ISSUE TO CLIENT 23-12-2017
SCALE 1:100UNIT 6 FIRST FLOOR PLAN
3450
LOUNGE
KITCHEN
BED 2
BED 3
BATHWC
LAUNDRY
ENTRY
ENSUITE
BED 1
392590
288090
127590 250
LINENB.I.R
B.I.C
2501755
903880
2501755
904480
90900
902085
903100
250
2504175
90 907570
250
2505020
907570
250
4930
9022
5090
2750
250
250
3020
9030
0090
3910
250
61090
3300
250
250
5710
9014
7090
2750
250
S
250
250
1005
B.I.R
600
90790
1500arch
1000
1061
0
B.I.R
06.06 09.85
10.1
2
20.1
8
20.21 20.2110.15
06.2
7
20.21
09.1
2
AD14
AD14
S
UNIT 6c
D6.9
c
cct
ctct
ct
ct
ff
1400
DOWN
6710
1000
HIG
H BA
LUST
RAD
E
BALC
ON
Y
dp dp
dpdp
D6.1D6.3
D6.
5
D6.
4
D6.
6
D6.
7
D6.
10
D6.2
D6.8c
S
LEGEND
HARDWIRED SMOKE ALARM WITH BATTERY BACK-UPDOWNPIPEFLOOR WASTE
FLOOR COVERING LEGEND
c - CARPETff - FLOATING FLOORct - CERAMIC TILE
13180
fwfw fw
fwdp
GENERAL FINISHES
UNIT 6
CEILINGS - FLUSHED PLASTERBOARDCORNICE - 55mm COVE CORNICE
WALLSFLUSHED PLASTERBOARD GENERALLY , FRC TO WET AREAS
DOORS INTERNAL PAINTED FLUSH PANEL HOLLOW CORESLIDER TO LAUNDRYEXTERNAL PAINTED FLUSH PANEL SOLID COREPOWDERCOATED SECURITY SCREEN DOORS TO EXTERNAL DOOR OPENINGS
WINDOWSPOWDERCOATED ALUMINIUM WITH FLYSCREEN
SKIRTING BOARD 90X19 SINGLE BEVELARCHITRAVES 42X19 SINGLE BEVEL
JOINERY
BED 11800X600 BUILT IN ROBE, MELAMINE FRAME AND SHELVES, HANGING RAIL2 SLIDING FLUSH PANEL DOORS
BED 2
1735X600 BUILT IN ROBE, MELAMINE FRAME AND SHELVES, HANGING RAIL2 SLIDING FLUSH PANEL DOORS. MEASURE ALCOVE ON SITE BEFOREMANUFACTURE
BEDROOM 3
2730X600 BUILT IN ROBE, MELAMINE FRAME AND SHELVES, HANGING RAIL2 SLIDING FLUSH PANEL DOORS. MEASURE ALCOVE ON SITE BEFOREMANUFACTURE
LINEN
1275X470 MELAMINE FRAME AND SHELVING, MELAMINE HINGED DOORS.MEASURE ALCOVE BEFORE MANUFACTURE.
SET DOWN WET AREAS - 45mm
w/m
rf
'P' TRAP WC 'P' TRAP WC
HWS IN CUPBOARD. PROVIDE TUNDISH FORPRESSURE RELIEF VALVE DISCHARGE.
fallfw
PASSAGE
PROPRIETARY WEBFORGE GALVANISED STAIRCASE, BALUSTRADE AND HANDRAIL. USINGPROFILED GALVANISED CHECKER PLATETREADS AND LANDING
STAIRCASE, BALCONY AND LANDING SHALLBE IN ACCORDANCE WITH THE NCCD2.13 GOINGS AND RISERSD2.14 - LANDINGSD2.16 BARRIERS TO PREVENT FALLSD2.17 HANDRAILS
1400
4750
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
100
step
dow
n
SMOKE ALARM TOUNIT 5 BEDROOM 2
SHALL BEINTERCONNECTEDWITH UNIT 6 ENTRY
SMOKE ALARM
150
150
FL103.318
DESCRIPTIONREVISION DATE
SCALE :
DESIGN :
DRAWN :
DATE :
FILE REF :
DWG NO :
AT
REV No :
OFSHEET SIZETHIS DRAWING SHALL NOT BE USED OR RELIED UPON BY PARTIES OTHER THAN THENAMED CLIENT, AND/OR THEIR APPOINTED BUILDERS AND SUB-CONTRACTORS.DRAWINGS ARE NOT TO BE SCALED. ALL WRITTEN DIMENSIONS AND LEVELS ARE TOBE VERIFIED ON SITE PRIOR TO THE ORDER OF MATERIALS AND CONSTRUCTION.
ADELAIDE P: +61 8 8150 5500
SYDNEY
BRISBANE
HOBART
MELBOURNE
P: +61 7 3844 8440
P: +61 3 9036 3079
P: +61 3 9036 3079
P: +61 2 9509 0700
impartaengineers.com.au
ABN: 58 086 672 915
W:Mountford Prider Pty Ltd
CLIENT:C/-REF No: I/O:
REPLACEMENT OF FIRE-DAMAGED UNITS
98 Must StreetPORTLAND VIC 3305
FIRST FLOOR PLAN1:100
STL
GTH
23-12-2017
0760917STL
D6
A
26A3
Strata Unit Underwriting Agency Pty LtdCunningham Lindsey Australia Pty Ltd03015168 18092017 OC015168
NO
RTH
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE SCOPE OF WORKS
0 1 2 3 4 5m
REV. A ISSUE TO CLIENT 23-12-2017
SCALE 1:100EAST ELEVATION
SCALE 1:100SOUTH ELEVATION
SCALE 1:100NORTH ELEVATION
SCALE 1:100WEST ELEVATION
STEEL ROOF SHEETINGTO CORROSIONENVIRONMENT
COLORBONDGUTTERS WITH OVERFLOW PROTECTION
FACEBRICKMASONRY TOEXTERNAL WALL TOOWNER'S SELECTION
ENTRY STAIRCASE
PVC DOWNPIPES
COLORBOND STEEL CLADDINGINFILL. COLORBOND FLASHINGAND VERTICAL EDGESSOLID EXTERNAL DOORS (TYPICAL)
2450
CL
FL
FL
2693
2450
CL
FL
FL
VERANDAH STRUCTURESSHOWN DASHED
UNIT 5UNIT 4
UNIT 4UNIT 5
UNIT 5
UNIT 6UNIT 6
UNIT 5
UNIT 6
UNIT 4
UNIT 6UNIT 6
POWDERCOATED SECURITY SCREEN DOORPOWDERCOATED SECURITYSCREEN DOOR
HOT WATER SERVICE ONCONCRETE PAD
PROPOSED HOTWATER SERVICE ON
CONCRETE PAD
POLYCARBONATEROOF DECK TOVERANDAHS
DUCTED EXHAUSTFAN, SELF CLOSINGDAMPER (TYPICAL)
GALVANISED HANDRAIL, BALUSTRADE,TREADS, LANDING AND FRAME.
VERTICAL BALUSTERS. GAPS SHALL NOTPERMIT THE PASSING THROUGH OF A
125mm SPHERE
OBSCURED GLAZING TO WETAREA WINDOWS (TYPICAL)
UPPER STOREY WINDOWS TO BEFITTED WITH A DEVICE TO LIMIT THEOPENING OR A SUITABLE SCREEN SOAS 125mm SPHERE CANNOT PASSTHROUGH.
BARGE CAP
10mm FOIL BOARD TO BE INSTALLEDTO EXTERNAL CAVITY MASONRYWALLS
LOUNGE WINDOW,SILL TO BE LOCATED1.5M ABOVE FLOOR
LEVEL INACCORDANCE WITH
CLAUSE C3.11(g)(v)(B)
2453
U/S OFFLOORFRAME
2693
2453
U/S OFFLOORFRAME
CL
CL
1500
1000
UNIT 6 ELECTRICAL SUPPLYIN CONDUIT BROUGHT UPEXTERNAL FACE OF WALL
METER BOXES
METER BOX
DENOTES EXTENT OF BEDJOINT LADDERREINFORCEMENT. REFER TO DRAWING D12FOR ADDITIONAL DETAIL. DO NOT CONTINUETHROUGH MASONRY CONTROL JOINTS
PROPRIETARYSTEELFRAMEDVERANDAH
GALVANISED VENTILATION'BRICK' (TYPICAL) ATFLOOR/CEILING SPACE
GALVANISED VENTS (TYPICAL)
RENDERED, PAINTED FRC BALCONY BALUSTRADE,COLORBOND CAP. 70mm GAP AT BOTTOM EDGEFOR DRAINAGE OF TILE DECK
EXTERNAL SEWER STACKS ANDVENTPIPES NOT SHOWN.
DENOTES FIRE RATED MINERAL FIBRE WOOLCAVITY BARRIER LOCATION
aj aj
ajajaj
aj
aj
ajaj
aj - ARTICULATION JOINT
DESCRIPTIONREVISION DATE
SCALE :
DESIGN :
DRAWN :
DATE :
FILE REF :
DWG NO :
AT
REV No :
OFSHEET SIZETHIS DRAWING SHALL NOT BE USED OR RELIED UPON BY PARTIES OTHER THAN THENAMED CLIENT, AND/OR THEIR APPOINTED BUILDERS AND SUB-CONTRACTORS.DRAWINGS ARE NOT TO BE SCALED. ALL WRITTEN DIMENSIONS AND LEVELS ARE TOBE VERIFIED ON SITE PRIOR TO THE ORDER OF MATERIALS AND CONSTRUCTION.
ADELAIDE P: +61 8 8150 5500
SYDNEY
BRISBANE
HOBART
MELBOURNE
P: +61 7 3844 8440
P: +61 3 9036 3079
P: +61 3 9036 3079
P: +61 2 9509 0700
impartaengineers.com.au
ABN: 58 086 672 915
W:Mountford Prider Pty Ltd
CLIENT:C/-REF No: I/O:
REPLACEMENT OF FIRE-DAMAGED UNITS
98 Must StreetPORTLAND VIC 3305
ELEVATIONS1:100
STL
GTH
23-12-2017
0760917STL
D7
A
26A3
Strata Unit Underwriting Agency Pty LtdCunningham Lindsey Australia Pty Ltd03015168 18092017 OC015168
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE SCOPE OF WORKS
0 1 2 3 4 5m
REV. A ISSUE TO CLIENT 23-12-2017