sterisensor autoclave chamber/load sensor · 2017. 2. 13. · • pg2 (s316l/sfa10w)av: pg2 sealing...

4
Tel: 1.716.684.4500 • USA Toll Free: 1.800.223.2389 • Email: [email protected] • Website: www.conaxtechnologies.com Sterisensor ® Autoclave Chamber/Load Sensor Sterisensor® withstands the environmental conditions found in pharmaceutical autoclave chambers. Sterisensor’s engineered moisture seal prevents the ingress of moisture which is the leading cause of failure. Thermocouple Type T or RTD, 100Ω@0ºC, .00385Ω/ Ω/ºC calibrations are available, sensor lengths and diameters are configured to meet application requirements. Mechanical Sensor Diameter: 3.0mm, 3.18mm (.125”), 4.76mm (.187”), 6.0mm, 6.35 (.250”) Sensor Length: 75mm (3”) minimum, 305mm (12”) maximum Sheath Material: • 316 Stainless Steel Leadwire/Jacket Length: • 900mm (36”) length minimum RTD Element: Single or dual PT 100 with 3 or 4 wire connection, Class ‘B’, and ‘A’ tolerance meeting BS EN 60751:1996. Fractional 1/10 tolerance available. Leadwire/Jacket: PTFE insulated 26AWG stranded conductors with thick walled extruded silicone rubber jacket Operating Range: -50ºC to +150VC (-58ºF to +302ºF) Vacuum to 3.5 BAR (50 PSIG) Note: Multiple detector configurations are determined by the sensor diameter. Thermocouple Type: Type T: Single or Dual to ASTM E230 Leadwire/Jacket: PTFE insulated 24AWG stranded conductors with thick walled extruded silicone rubber jacket Operating Range: -50ºC to +150ºC (-58ºF to +302ºF) Vacuum to 3.5 BAR (50 PSIG) Accessories Various types of leadwire sealing gland assemblies are available. Refer to Conax Technologies’ Catalog 5001C. Sterisensor® with chisel point

Upload: others

Post on 31-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Tel: 1.716.684.4500 • USA Toll Free: 1.800.223.2389 • Email: [email protected] • Website: www.conaxtechnologies.com

    Sterisensor® Autoclave Chamber/Load SensorSterisensor® withstands the environmental conditions found in pharmaceutical autoclave chambers. Sterisensor’s engineered moisture seal prevents the ingress of moisture which is the leading cause of failure.

    Thermocouple Type T or RTD, 100Ω@0ºC, .00385Ω/Ω/ºC calibrations are available, sensor lengths and diameters are configured to meet application requirements.

    MechanicalSensor Diameter:

    • 3.0mm, 3.18mm (.125”), 4.76mm (.187”), 6.0mm, 6.35 (.250”)

    Sensor Length: • 75mm (3”) minimum, 305mm (12”) maximum

    Sheath Material: • 316 Stainless Steel

    Leadwire/Jacket Length: • 900mm (36”) length minimum

    RTDElement:

    • Single or dual PT 100 with 3 or 4 wire connection, Class ‘B’, and ‘A’ tolerance meeting BS EN 60751:1996. Fractional 1/10 tolerance available.

    Leadwire/Jacket: • PTFE insulated 26AWG stranded conductors

    with thick walled extruded silicone rubber jacket

    Operating Range: • -50ºC to +150VC (-58ºF to +302ºF)• Vacuum to 3.5 BAR (50 PSIG)

    Note: Multiple detector configurations are determined by the sensor diameter.

    ThermocoupleType:

    • Type T: Single or Dual to ASTM E230

    Leadwire/Jacket: • PTFE insulated 24AWG stranded conductors

    with thick walled extruded silicone rubber jacket

    Operating Range: • -50ºC to +150ºC (-58ºF to +302ºF)• Vacuum to 3.5 BAR (50 PSIG)

    Accessories• Various types of leadwire sealing gland

    assemblies are available. Refer to Conax Technologies’ Catalog 5001C.

    Sterisensor® with chisel point

  • 1. Tip Configuration: • 5 = Enclosed, welded closed

    • 6 = chisel point, welded closed

    2. RTD Type and Tolerance: • 100Ω@0ºC, α = .00385Ω/Ω/ºC:• W = Class B (±.3ºC@0ºC)• S = Class A (±.15ºC@0ºC)• R = 1/10 Class B (±.03ºC@0ºC)

    3. Sensor Lead Configuration / Available Sensor Diameter:• 3 = Single 3-Wire / All Dia.• 4 = Single 4-Wire / All Dia.• 7 = Dual 3-Wire / ≥4.76mm (.187” Dia.)• 8 = Dual 4-Wire / ≥4.76mm (.187” Dia.)

    4. Sensor Diameter:• 300 = 3.00mm• 320 = 3.18mm (.125”)• 476 = 4.76mm (.187”)• 600 = 6.00mm• 635 = 6.35mm (.250”)

    RTD Type

    EXAMPLE: SSA6-RTD43W3-316SS635-LEAD(1000mm/100mm)-PG2AV-300mm

    SSA -RTD43 -316SS -LEAD( mm/ mm)- - mm

    1 2 3 4 5 6 7 8

    5. Length - (mm) of overall leadwire: • Maximum overall leadwire length - 6100mm (240”)• Minimum silicone protection jacket length - 900mm

    (36”)

    6. Length (mm) of exposed Teflon® leadwire with 12.70mm (1/2”) bare lead: • Minimum exposed leadwire length - 75mm (3”)• Maximum exposed leadwire length - 200mm (8”)

    7. Specify sealing gland type:• X = not required• MPGAV: .125 NPT mounting thread Viton® sealant

    • PG2AV: .250 NPT mounting thread Viton sealant

    • PG2 (S316L/SFA10W)AV: PG2 sealing gland welded to 1 & 1 ½” 16 AMP sanitary flange, Viton sealant

    8. Length (mm) of sensor sheath:• Minimum sensor sheath length - 75mm (3”)• Maximum sensor sheath length - 305mm (12”)

    Note: Consult factory for catalog number for optional bending and reduced tip sensor configurations. RTD types S and R are recommended with four wire lead configuration. Refer to Conax Technologies’ Catalog 5001C or www.conaxtechnologies.com for additional compression seal fitting (Sealing Gland) information.

    Sterisensor® Assembly Description for RTD’S

    Tel: 1.716.684.4500 • USA Toll Free: 1.800.223.2389 • Email: [email protected] • Website: www.conaxtechnologies.com

  • 1. Tip Configuration:• 5 = Ungrounded, welded closed

    • 6 = Chisel point, ungrounded, welded closed

    2. Thermocouple Type:• T = Copper/Constantan

    3. Sensor Diameter:• 300 = 3.00mm• 320 = 3.18mm (.125”)• 476 = 4.76mm (.187”)• 600 = 6.00mm• 635 = 6.35mm (.250”)

    4. Thermocouple Configuration/Available Sensor Diameter:

    • U = Single 2-wire• 2U = Dual 4-wire

    Thermocouple Type5. Length - (mm) of overall leadwire:

    • Maximum overall leadwire length - 6100mm (240”)• Minimum silicone protection jacket length -

    900mm (36”)

    6. Length (mm) of exposed Teflon leadwire with 12.70mm (1/2”) bare lead:

    • Minimum exposed leadwire length - 75mm (3”)• Maximum exposed leadwire length - 200mm (8”)

    7. Specify sealing gland type:• X = not required• MPGAV: .125 NPT mounting thread Viton sealant

    • PG2AV: .250 NPT mounting thread Viton sealant

    • PG2 (S316L/SFA10W)AV: PG2 sealing gland welded to 1 & 1-½” 16 AMP sanitary flange, Viton sealant

    8. Length (mm) of sensor sheath:• Minimum sensor sheath length - 75mm (3”)• Maximum sensor sheath length - 305mm (12”)

    EXAMPLE: SSA6-T-316SS635-U-LEAD(1000mm/100mm)PG2AV-300mm

    SSA -RTD43 -316SS -LEAD( mm/ mm)- - mm SSA - 316SS - -LEAD( mm/ mm)- - mm

    1 2 3 4 5 6 7 8

    Note: Consult factory for catalog number for optional bending and reduced tip sensor configurations. Refer to Conax Technologies’ Catalog 5001C or www.conaxtechnologies.com for additional compression seal fitting (sealing gland) information

    Sterisensor® Assembly Description for Thermocouples

    Tel: 1.716.684.4500 • USA Toll Free: 1.800.223.2389 • Email: [email protected] • Website: www.conaxtechnologies.com

  • © 2010 Conax Technologies Bulletin 6009 03/10

    2300 Walden AvenueBuffalo, New York 14225, USA

    Fax: 716-684-7433 • Phone: 716-684-4500Toll free in the USA at 1-800-223-2389E-mail: [email protected]: www.conaxtechnologies.com

    The environmental conditions found in pharmaceutical autoclave chambers are extreme for any equipment. These same conditions are a major cause of sensor failure in chamber/load probes. This is due to the ingress of moisture into the sensor and the unacceptable leakage of steam/condensate through the bulkhead connection.

    The Sterimaster® Chamber/Load Sensor has been designed to withstand these conditions and offers a reliability factor surpassing that previously obtainable. Every weld undergoes NDT examination and each completed assembly is leak tested.

    RTD and thermocouple assemblies are available. Further information can be found in Conax Technologies’ Sterimaster Bulletin 6012. Contact your Conax Technologies representative, our Sales offices, or go to our website to obtain a copy.

    Teflon and Viton are registered trademarks of E.I. Dupont de Nemours & Co. Sterimaster® is a registered trademark of Thermal Detection Ltd. Sterisensor® is a registered trademark of Conax Technologies LLC but is manufactured by Thermal Detection Ltd.

    Catalog 5005

    Please visit www.conaxtechnologies.com for technical data on temperature sensors, thermocouples, RTDs, thermowells, transmitters, special assemblies and more.

    Request Catalog 5005, our RTD & Thermocouple Assemblies Handbook

    Sterimaster® Chamber/Load Sensor

    Sterimaster® Autoclave Chamber/Load Sensor