stormwater chamber system chamber syst… · (knock out pit) c-m concrete pbs 750 hydracell (knock...

18
P: (07) 3804 6622 F: (07) 3804 6699 e: [email protected] w: cmconcrete.com.au Branch Office: 13-15 Enterprise Drive BEAUDESERT QLD 4285 Head Office: 4 Quarry Road STAPYLTON QLD PO Box 167 BEENLEIGH QLD 4207 Hydracell 1050 System Jump Pit Hydradapt 600 Hydracell 600 Hydracell Accessories 750 Short Hydracell 750 Hydracell Accessories 900 Hydracell 900 Hydracell Accessories 1050 Hydracell 1050 Hydracell Accessories Field Inlet Type 1 Field Inlet Type 1 - Modified 1500 x 1500 Field Inlet Type 1 - TMR Vee Grated Surround 66D Vee Grated Surround 69D Turret Riser C-M Stormwater Chamber System Index

Upload: others

Post on 23-Jun-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

• Hydracell 1050 System

• Jump Pit

• Hydradapt

• 600 Hydracell

• 600 Hydracell Accessories

• 750 Short Hydracell

• 750 Hydracell Accessories

• 900 Hydracell

• 900 Hydracell Accessories

• 1050 Hydracell

• 1050 Hydracell Accessories

• Field Inlet Type 1

• Field Inlet Type 1 - Modified 1500 x 1500

• Field Inlet Type 1 - TMR

• Vee Grated Surround 66D

• Vee Grated Surround 69D

• Turret Riser

C-M Stormwater Chamber System Index

Page 2: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

TOP GULLY UNIT DOES NOT HAVE TO BE SQUARE TO PIT

1050 HYDRACELL

1050 Riser

C-M ROAD GULLY

UNIT

(KNOCK-OUT PIT)

ASPRO

HYDRACELL RISERS AVAILABLE: 1050 - 150mm 1050 - 300mm 1050 - 600mm 1050 - 900mm

1050 - 1200mm 1050 - Jump Pit

C-M CONCRETE PRODUCTS

HYDRACELL 1050 SYSTEMHYDRACELL 1050 SYSTEMHYDRACELL 1050 SYSTEMHYDRACELL 1050 SYSTEM

Page 3: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

1050 Jump Pit Knock Out Pit

• Pit Base and Riser accepts up to 750 diameter pipe (600 Recommended).

• Square to round shape achieves bell mouth design to lower head loss.

• Distance between invert and ovevert

of base and riser 1560.

• Pipe can be located between base and riser.

• N40 Concrete • Reinforcing to AS 1302

Page 4: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

Accepts up to 375mm Dia FRP

Accepts up to 525mm Dia FRP

Hydradapt Triangular Unit is

Reversible

Hydradapt is a patented concrete adaptor for use in conjunction with the C-M 1050 Hydracell Pit Base.

The Hydradapt can also be used as a standalone adaptor which can be retro fitted to existing in-situ pit that requires additional pipes. This process can be done without the destruction of the

original in-situ pit.

Page 5: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

HYDRACELL 600 (KNOCK OUT PIT)

C-M Concrete PB 600 Hydracell (Knock Out Pit)

Concrete to AS3902 Concrete Strength 40MPa

Reinforcing: 1 x 1100 x 1100 F72 Mesh 1 x Y10 Lig 1100 x 110

Reinforcing to AS1302

Patent Applies

2 x 1.3T Swiftlifts Weight: 350Kg

Accepts up to 375 Dia Pipe

ELEVATION

PLAN

780

780 Ø 600

440

110

600

50

Page 6: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

600 HYDRACELL Covers & Grated Tops with Concrete Surrounds

RGU - For Use in Car Parks and Anti-Ponding requirements

1m x 1m

200

600 Opening

Rebate 25mm For 600 FRC = 175 Top Surface to FRC

600 x 600 Light Duty Grate 600 x 600 Heavy Duty Grate

Both Lock Down

Concrete Lid

600 x 600 'V' Grated Surround Class 'D' Grate Class 'B' Grate

485 x 485 Grate 400 C/O Square Surround with Class 'B' Grate

(Drop in Only)

Page 7: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

HYDRACELL 750 SHORT (KNOCK OUT PIT)

C-M Concrete PBS 750 Hydracell (Knock Out Pit)

Concrete to AS3902 Concrete Strength 40MPa

Reinforcing: 1 x 750 x 750 F41 Mesh 1 x Y10 Lig 800 x 800 Reinforcing to AS1302

Patent Applies

2 x 1.3T Swiftlifts Weight: 550Kg

Accepts up to 375 Dia Pipe

ELEVATION

PLAN

900

900 Ø 750

475

110

600

50

Page 8: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

750 HYDRACELL Grated Top with Concrete Surrounds & Concrete Covers

To Suit 750 Short Base

Concrete Lid 90Kg

200

250Kg

200

25mm Rebate = 175 Pipe to Surface Level

Light Duty 600 x 600

Heavy Duty 600 x 600

Both Lock Down Grates

550 x 550 Square Grate 450 C/O

Page 9: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

HYDRACELL 900 (KNOCK OUT PIT)

C-M Concrete PB 900 Hydracell (Knock Out Pit)

Concrete to AS3902 Concrete Strength 40MPa

Reinforcing: 1 x 1000 x 1000 F72 Mesh 1 x Y10 Lig 950 x 950 Reinforcing to AS1302

Patent Applies

2 x 1.3T Swiftlifts Weight: 1050Kg

Accepts up to 600 Dia Pipe

ELEVATION

PLAN

1070

1070 Ø 900

740

180

970

50

Page 10: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

900 HYDRACELL Grated Tops with Concrete Surrounds

600 x 600 Grated Surround with Heavy Duty/Class 'B' Grated Surround 600 x 900 Grated Lock Down

150

1500

1200

600 x 600

150

600

1050 Sq

200

1200

Concrete Surround with 600 x 900 Heavy Duty

Class 'D' Heavy Duty/Light Duty

Optional Cast Iron Cover & Surround

Page 11: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

• Concrete to AS3902

• Concrete Strength 40MPa • Reinforcing: 1 x 1100 x 1100 F72 Mesh 1 x Y12 Lig 1100 x 1100 Reinforcing to AS1302

Patent Applies

• 2 x 1.3T Swiftlifts

• Weight: 1500Kg

• Accepts up to 750 Dia Pipe

ELEVATION

890

160

1100

50 PLAN

1200

1200 Ø 1050

HYDRACELL 1050 (KNOCK OUT PIT)

Page 12: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

1050 HYDRACELL Grated Surrounds and Covers

1200 x 1500 Grated Surround with 600 x 900 Grate - Heavy Duty/Class 'D' - Light Duty

1200 x 1200 Roof Slab with 600 Diameter Access

Opening

1200 1200

200

Optional Products To Suit 1050 Pit Base

RGU Road Gully Units 2.4 3.6 4.8 'S' 'M' 'L'

Main Roads Approval Drawings 1443 - 1444 IPWEA Approval Drawings D0069 - D0070

Cast Iron Covers Class 'B'/Class 'D'

Page 13: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

Optional Grates to Specifications E.g. 900x900 IMEAQ Type 1 600x900 Dome Top Cover

Allows Completion of Inlet Construction in Same Day

Used in Conjunction with

our 1050 Hydracell

Arrives on Site Complete

with Grate Fitted

Overflow Gully Field Inlet Type 1

(Also available: TMR Type 2 Field Inlet w/- 20mm Flat Bar Type J G/F on Legs)

Grate Standard – AS 3996

Page 14: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

C-M Precast Field Inlet Surround

Available Opening Sizes: 6x6, 6x9, 9x9

Type 1 (Modified 1500 x 1500) w/- G/F on Legs

Page 15: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

Field Inlet Type 1 - TMR

Notes: 1. Concrete S40 TMR 2. Reo: F72 Mesh, Y12 Lig 3. Galvanised Grate & Frame as Specified to AS3996 - Class B 4. 50mm Clear Cover

5. Opening Size: 900x600 or 600x600

Page 16: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

C-M VEE GRATED SURROUND 66D

• Concrete S40

• V-Grate 600 x 600 AS3996

• Exposure Class B2

• Reo 12Y Fabricated

50mm

1000mm

1000mm

Page 17: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

C-M VEE GRATED SURROUND 96D

• Concrete S40

• V-Grate 900 x 600 AS3996

• Exposure Class B2

• Reo 12Y Fabricated

50mm

1350mm

1000mm

Page 18: Stormwater Chamber System Chamber Syst… · (KNOCK OUT PIT) C-M Concrete PBS 750 Hydracell (Knock Out Pit) Concrete to AS3902 Concrete Strength 40MPa Reinforcing: 1 x 750 x 750 F41

P: (07) 3804 6622 F: (07) 3804 6699

e: [email protected] w: cmconcrete.com.au

Branch Office:

13-15 Enterprise Drive

BEAUDESERT QLD 4285

Head Office:

4 Quarry Road STAPYLTON QLD

PO Box 167 BEENLEIGH QLD 4207

C-M 1050 TURRET RISER To Suit 1050 – 1200 – 1500 Diameter Pipe

PLAN

1200

1200 Ø 1050

570

RCP 1050 1200 1500

Turret

Available Risers

1050 Hydracell Riser System to fit

Turret Riser

• 150 – 300 – 600 – 900

• 1050 Jump Pit Riser • Standard 1050 Convertor Slab • 600 Class D Upstand