Page 1: Straight Forward Solutions for your Daily Lab Applications

Straight Forward Solutions For your Daily Applications

Page 2: Straight Forward Solutions for your Daily Lab Applications

Our solutions all share the same mindset

pHWeighingWeighingME balances offer all the functionality you need for your weighing tasks. Easy to use and clean, you’re guaranteed to complete your daily tasks faster and more efficiently, while the solid construction means you can rely on accurate results for many years to come. Page 4-7

pH MeasurementThe SevenCompact meter provide intuitive operation and high measurement accuracy. Combined with excellent sensors, it is the perfect solution for your pH measurement.Page 8-9

$500*from

$1266*from

In order to best serve your daily application, our products all share the same mindset: robust, precise, reliable and simple to use

Find out how intuitive and straight forward your daily measuring tasks could become. Benefit from some of our great promotions

2

Page 3: Straight Forward Solutions for your Daily Lab Applications

Our solutions all share the same mindset

RaininTitrationTitrationMake your first step into the world of automated titration. EasyPlus™ titrators provide an easy and affordable titrating solution that increases your measurement precision and repeatability. Page 10-11

Ergonomic Pipettes Gain greater confidence in your data with Rainin’s new family of XLS+ manual and electronic pipettes. Manufactured with the highest quality materials, XLS+ pipettes will provide you with superior performance, year after year. Page 12-13

$3830*

Robust Precise Reliable Simple to use

fromfrom

$272*

3

Page 4: Straight Forward Solutions for your Daily Lab Applications

Avoid weighing errors Download ourTips&Tricks Poster!

www.mt.com/basic-lab

ME Precision Balance

Tips and Tricks

To Avoid Weighing Errors

L1. Working table

•Useasta

bletablewith

anantimag

neticsurface

•Protectit

againstelec

trostaticcha

rges

• Itshouldb

efixedtoeit

herthewall

orthefloor,

butnotbot

h

L2. Working room

•Thetable

shouldbepl

acedinthe

cornerofth

eroom;ina

building,

it’sthepl

acewiththe

leastvibrati

on

•Theroom

shouldbe

freefromdr

afts

L3. Room temperature

•Keepthe

roomtempe

ratureasst

ableaspos

sible,20-25

ºC

•Donotlo

catethebala

ncenearra

diatorsorw

indows

Tip:Balancesw

ithFACTauto

maticintern

aladjustme

ntcancomp

ensate

forvirtuall

yalltherem

ainingtemp

eraturedrift

.

L4. Humidity

•Donotop

eratetheba

lanceabove

orbelowth

emeasuring

rangeof

20-80%

rH

L5. Light as a heat source

•Donotpl

acethebala

nceindirect

sunlight.

•Placethe

balanceaw

ayfromoth

erlightsour

ces,especia

llylightbulb

s.

L6. Air

•Donotpl

acethebala

nceinthea

irflowofair

conditioner

sordevices

withventil

ators.

•Placethe

balanceaw

ayfromrad

iators.

Tip:Openthed

raftshieldof

thebalance

onlyasfar

asnecessa

ry.

Find out more about good weighing practices – Download the booklet:

www.mt.com/proper-weighing-lab

www.mt.com/gwpForm

oreinforma

tion

©06/2013

Mettler-Toled

oAG

PrintedinS

witzerland3

0092460

GlobalMarC

omSwitzerla

nd

Location Matters –

IsyourBala

nceintheC

orrectPlace?

The location of your balance has a direct impact on the precision and

reproducibility of your weighing results.

O1. Switching on

•Donotdi

sconnectthe

balancefro

mthepowe

rsupply

•Thebalan

ceshouldal

waysbeleft

switchedo

n

O2. Leveling

•Ensureth

ebalanceis

levelbych

eckingthatt

heairbubb

leisinthec

enterof

thelevelindi

cator.

O3. Weighing vessel

•Usethes

mallestposs

ibleweighin

gvessel

•Avoidwei

ghingvesse

lsmadeof

plasticwhen

atmospher

ichumidityis

below30-4

0%.

O4. Weighing pan

•Alwaysp

lacethesam

pleinthem

iddleofthew

eighingpan

•Takecare

whenusing

magneticst

irbars

O5. Reading

•Checktha

tthebalance

displaysexa

ctlyzerobef

oreweighin

g

•Tareafter

placingthe

weighingve

sselonthe

balance

•Ensureth

atthereadi

ngisstable

beforereco

rdingthere

sult

O6. Sample

•Avoidtou

chingthesa

mpleandw

eighingvess

el

•Acclimatiz

ethesamp

leandweigh

ingvesselb

eforeweigh

ing

•Beaware

ofpossible

electrostatic

chargingof

thesample

and

weighing

vessel

Operating Your Balance –

AvoidComm

onErrors

Correct handling of your balance and sample is essential to minimize external

influences on your weighing results.

R1. How to test your balance

•Warmup

thebalance

•Cleanthe

balancepa

nbeforetest

ing

•Levelthe

balance

•Performt

hetestinac

cordancew

ithyourSOP

R2. Weights

•Usecertif

iedweights

inthecorre

ctweightcla

ss(OIML,A

STM)

•Alwaysu

seglovesan

dtweezers

whenhandl

ingweights

Tip:CarePacw

eightsetsco

ntainjusttw

ocarefullys

electedweig

htsandall

theaccesso

riesyounee

dforworry-fr

eebalance

testing.

R3. Good Weighing Practice™

METTLERTO

LEDO’sGoo

dWeighing

Practice

™ isaglobal

risk-based

weighing

guidelineth

athelpsyou

maketheri

ghtdecision

whereitre

allymatters:

Evaluation,s

election,ins

tallation,ope

rationandt

estingofyo

urweighing

system.

Advantages

ofusingGW

P® anditssolu

tionsare:

•Adviceon

howtocho

osethecorr

ectbalance

foryourreq

uirements

•Guidance

onhandling

andmainten

anceofthe

balanceto

alwaysach

ieve

accuratere

sults

•Recomme

ndationsfor

therightte

stingscena

rios

•Reduced

costsands

ecureaudits

Routine Testing –

YourInsura

nceforExac

tResults

Routine testing verifies your balance is performing within specifications and

ensures valid results.

Common Problems and Explanations

Problem:Weightdisp

layofa

weighingsa

mpledrifts

inone

direction.

Possible Explanation:

Temperature

influenceso

nthe

balance

Problem: Weightdisp

layofa

weighingsa

mpleperma

nently

driftsinone

direction

Possible Explanation:

Moisturegai

norlossby

the

weighingsa

mple

Problem: Eachweigh

ingshows

adifferentre

sult.Thewe

ight

displayisun

stable.Repe

atabil-

ityoftheres

ultispoor.

Possible Explanation:

Electrostatica

llycharged

weighingsa

mplesorve

ssels

Problem: Weightofa

weighing

sampledepe

ndsonitspo

sition

ontheweigh

ingpan.Rep

eat-

abilityofthe

resultispoo

r,but

displayisst

able

Possible Explanation:

Magneticw

eighingsam

plesor

vessels

Problem: More(true)

masson

platformtha

nisindicate

dby

thebalance

Possible Explanation: Air

buoyancy,te

mperatured

iffer-

ences,elect

rostaticcha

rging

Problem: Theweighin

gvalues

aredifferent

whenthew

eighing

heightchan

ges

Possible Explanation:

Interplayof

gravitational

force

andcentrifu

galaccelera

tion

Save timeDraft shields and pans are easy to remove for fast cleaning

Reliability Built in Full metal base and reinforced body ensure the balance is built to last

Simple to UseClear backlit display 10 Pre-programmed applications

Environmentally Friendly Up to 50% lower power consumption than other balances

The ME Balance Range Simply Reliable NEW

RELEASE

4

Page 5: Straight Forward Solutions for your Daily Lab Applications

ME Analytical balances feature a large, easy to clean draft shield to ensure weighing is fast and efficient.

• Capacities: 52g to 220g

• Readability: 0.1mg

• Available with or without internal adjustment

• 10 Pre-programed applications

Not sure what system is best for your application?

Call us: 1300 659 761 or email at [email protected]

Solid construction ensures reliable results for many years to come. Intuitive keypad provides easy access to menus and applications including counting, checkweighing and formulation.

• Capacities: 120g to 4,200g

• Readability: 0.001g or 0.01g

• Available with or without internal adjustments

• 10 Pre-programmed applications

ME Analytical Balance

ME Precision Balance

Contact us to request a demonstration, discuss a customised system or for advice on a system that suits your requirments

5

Page 6: Straight Forward Solutions for your Daily Lab Applications

Make the most of your balance with quality accessories. A wide range of accessories are available to extend the capability of your balance and provide ongoing performance checking and protection

Balance Accessories Pr

inte

rs

Calib

ratio

n W

eigh

ts

Cove

rs

• Ideal for routine balance testing • All weights made from high grade stainless steel

• Hardcopy of all results with date and time• Transcription errors eliminated

• Dust covers • Replacement in-use

Lab

X Di

rect

For more information

For more information

For more information

www.mt.com/LabX

www.mt.com/printers

www.mt.com/weights

•Download results direct to PC for additional processing

6

Page 7: Straight Forward Solutions for your Daily Lab Applications

Comprehensive Balance Range METTLER TOLEDO is the world’s leading supplier of laboratory balances. If your application requires a higher performance balance or moisture balance then you can be sure that we will have a suitable model in our extensive range.

MS

Serie

sM

oist

ure

Bala

nce

Mic

ro B

alan

ces

Exce

llenc

e An

alyt

ical

For more information

For more information

For more information

www.mt.com/xse-analytical

www.mt.com/ms-analytical

www.mt.com/moisture

•Accurate moisture determination in a wide range of samples

•Results in minutes •Easy to use •Extensive application support available

•The work horse of the METTER TOLEDO range of balances

•Full metal case to ensure exceptional shock and overload protection

•Automatic calibration ensures accurate results

For more information

www.mt.com/micro

•Lowest possible minimum weight •Ideal for specialised applications including

filter weighing and micro analysis•Weigh down to 0.000001g

•Exceptional weighing performance •Extensive range of features for

regulated environments

7

Page 8: Straight Forward Solutions for your Daily Lab Applications

The SevenCompact™ pH MeterCombining Intuition with Precision

pH Meter S220

Electrode Status Indicator Displays the condition of your electrode

Easy SetupPrecise measurement with the press of a key

Secure Data ManagementSecurely store up to 1000 measurements and transfer via USB

Download the pH Measurement Guide!

www.mt.com/basic-lab

High Quality ElectrodesSuitable for all pH applications*measures samples as small as 15µl

8

Page 9: Straight Forward Solutions for your Daily Lab Applications

Seve

n Co

mpa

ctFi

ve E

asy

Seve

n Go

Five

Go

METTLER TOLEDO have a wide range of Micro pH electrodes for small sample volumes, these include:InLab MicroInLab Micro Pro InLab Flex Micro InLab Ultra Micro

Contact METTLER TOLEDO for electrode selection advice or visit www.electrodes.net

Did you know?

$1160*from • Prominent high-resolution colour display

• Easy operation and professional calibration support

• A clear, well organised display • Simple pH measurements with 5 easy-to-

use buttons

• Portable meters for pH, conductivity and oxygen• Ergonomic and compact design

• Portable meters for pH, conductivity, oxygen and ion analysis• Robust measuring system with IP67 rating

$710*from

$670*from

$500*from

METTLER TOLEDO offers everything required for precise and reliable pH, ORP, ion concentration, conductivity and dissolved oxygen (DO, BOD) measurements with a range of benchtop and portable meters.

Comprehensive pH range

9

Page 10: Straight Forward Solutions for your Daily Lab Applications

The EasyPlus™ TitratorA Simple and Affordable Solution

Easy pH

Scho

ol e

xper

imen

ts

Natural science laws experience “live” –

learn easily

ABC

of T

itrat

ion

ABC of Titration

in Theory and Practice

Titration Theory

Increase reliabilityThe automated burette and sensor for endpoint detection increases precision and reproducibility

Save timeSet up routine testing with iTitrate™ intelligence in no time

Document resultsEliminate manual calculations. Print or store them on a computer with EasyDirect™ software

Download the ABC of Titration Guide!

www.mt.com/basic-lab

Applications include:pH and acidity

SaltKarl Fisher

Free fatty acids Peroxide value

10

Page 11: Straight Forward Solutions for your Daily Lab Applications

Increase reliabilityThe automated burette and sensor for endpoint detection increases precision and reproducibility

Still performing manual titrations?

• Reduce variation Increase precision with an automated

burette and immersed dispensing tip.

• Increase reproducability Eliminate overtitration and operator

dependent colour interpretation with sensors for EP detection.

• Automated results processing Avoid transcription errors with data

collection software or a printer.

• Double your productivity Save operator time by starting an

analysis then being free to move onto other tasks.

What could an automatic titrator do to improve your sample analysis?

All titrators purchased come with: • EasyPlus Tutorial • Online Help• PredefinedCalculation• Easy Direct PC connectivity

Not sure what system is best for your application?

Call us: 1300 659 761 or email at [email protected]

Contact us to request a demonstration, discuss a customised system or for advice on a system that suits your requirments

11

Page 12: Straight Forward Solutions for your Daily Lab Applications

The Pipet-Lite XLS+Performance you can Feel

Secure volume lock Snag proof lock design prevents accidential volume drift while allowing rapid volume adjustment, even while wearing gloves

Extreme Accuracy Built to last and manufacturerd with the highest quality materials, XLS+ pipettes are designed to deliver superior performance year after year

Total hand comfortWith an ergonomic design contoured finger hook, lighter springs and low-drag seals

www.mt.com/RaininXLS

Bench Posture - It Matters! Get your latest Rainin poster on lab ergonomics www.mt.com/benchposture

12

Page 13: Straight Forward Solutions for your Daily Lab Applications

Introducing the XLS+ Pipette Family E4

XLS

+ el

ectr

onic

pi

pette

GaingreaterconfidenceinyourdatawithRainin’snewfamilyofXLS+manualand electronic pipettes. They have new seals, lighter bodies, enhanced security and a host of new convenience and performance features.

XLS+

m

ultic

hann

els

• New Admin mode enhances GLP/GMP compliance • Pipette menu can be configured

to users preference • Custom protocols can now be

stored and quickly recalled

• Rainin’s LiteTouch technology minimises tip ejection force• Multi-dispense mode simplifies

repetitive microplate pipetting across all channels

How is your Pipetting Practice?Good Pipetting Practice (GPP) is Rainin’s comprehensive systematic approach to maximising pipette accuracy and repeatability

TakefiveminutestodoourGPPRiskCheck to see where risks lie in your currentworkflowandtogetinstantresults on how you can improve.

Check your pipetting risk now at www.mt.com/gpp

13

Page 14: Straight Forward Solutions for your Daily Lab Applications

Simple ProductsExcellent Services and Accessories

Rain

inpH

Met

er

Accessories

EasyDirect™ Software

Titra

tor

Buffer and SolutionsInLab Sensors

• Broad portfolio of high quality,

low maintenance sensors

• Cover any routine application,

incl. pH, Conductivity, Ion and DO

EasyPlus™ BNC Sensors

• High quality sensors for accurate

routine applications

• Delivered with quality certificate

and serial number for traceability

• Simple result data management

• Graphical representation

• Additional calculation

• Print and export functions

• Available as traditional or Rainin

Lite-Touch System

• Chemically resistant

• Keep your pipettes organised,

ready to use

• Roating carousel stand for up to

seven manual pipettes

Pipette Tips Pipette Storage

• Attractive bundle packages for

frequent users

14

Page 15: Straight Forward Solutions for your Daily Lab Applications

CarePac®

Support

VPac™

Self-Service

Do your own routine testing!

•Time saving test approach with a step-by-step

manual for SOP testing

•Do your own performance verification

•Easy and unbiased self-service

•Direct and comprehensive service and support

via internet

•Telephone or chat support

Local Presence with Field Support & Service METTLER TOLEDO is with you every step of the way, with application service support and techinical assistance, anytime and anywhere,feelconfidentinmakingthechange.

www.mt.com/service

• Melbourne • Sydney • Brisbane

• Central Queensland • Perth • Adelaide

15

Page 16: Straight Forward Solutions for your Daily Lab Applications

Enhance your knowledge and profit from some great whitepapers and webinars.

Tips and TricksTo Avoid Weighing Errors

L1. Working table •Useastabletablewithanantimagneticsurface•Protectitagainstelectrostaticcharges• Itshouldbefixedtoeitherthewallorthefloor,butnotboth

L2. Working room•Thetableshouldbeplacedinthecorneroftheroom;inabuilding,it’stheplacewiththeleastvibration•Theroomshouldbefreefromdrafts

L3. Room temperature•Keeptheroomtemperatureasstableaspossible,20-25ºC•Donotlocatethebalancenearradiatorsorwindows Tip:BalanceswithFACTautomaticinternaladjustmentcancompensateforvirtuallyalltheremainingtemperaturedrift.

L4. Humidity•Donotoperatethebalanceaboveorbelowthemeasuringrangeof20-80%rH

L5. Light as a heat source•Donotplacethebalanceindirectsunlight.•Placethebalanceawayfromotherlightsources,especiallylightbulbs.

L6. Air •Donotplacethebalanceintheairflowofairconditionersordeviceswithventilators.•Placethebalanceawayfromradiators. Tip:Openthedraftshieldofthebalanceonlyasfarasnecessary.

Find out more about good weighing practices – Download the booklet: www.mt.com/proper-weighing-lab

www.mt.com/gwpFormoreinformation

©06/2013Mettler-ToledoAGPrintedinSwitzerland30092460GlobalMarComSwitzerland

Location Matters – IsyourBalanceintheCorrectPlace?

The location of your balance has a direct impact on the precision and reproducibility of your weighing results.

O1. Switching on•Donotdisconnectthebalancefromthepowersupply•Thebalanceshouldalwaysbeleftswitchedon

O2. Leveling•Ensurethebalanceislevelbycheckingthattheairbubbleisinthecenterof thelevelindicator.

O3. Weighing vessel•Usethesmallestpossibleweighingvessel•Avoidweighingvesselsmadeofplasticwhenatmospherichumidityis below30-40%.

O4. Weighing pan•Alwaysplacethesampleinthemiddleoftheweighingpan•Takecarewhenusingmagneticstirbars O5. Reading•Checkthatthebalancedisplaysexactlyzerobeforeweighing•Tareafterplacingtheweighingvesselonthebalance•Ensurethatthereadingisstablebeforerecordingtheresult

O6. Sample•Avoidtouchingthesampleandweighingvessel•Acclimatizethesampleandweighingvesselbeforeweighing•Beawareofpossibleelectrostaticchargingofthesampleandweighingvessel

Operating Your Balance – AvoidCommonErrors

Correct handling of your balance and sample is essential to minimize external influences on your weighing results.

R1. How to test your balance•Warmupthebalance•Cleanthebalancepanbeforetesting•Levelthebalance•PerformthetestinaccordancewithyourSOP

R2. Weights •Usecertifiedweightsinthecorrectweightclass(OIML,ASTM)•Alwaysuseglovesandtweezerswhenhandlingweights Tip:CarePacweightsetscontainjusttwocarefullyselectedweightsandall theaccessoriesyouneedforworry-freebalancetesting.

R3. Good Weighing Practice™

METTLERTOLEDO’sGoodWeighingPractice™isaglobalrisk-basedweighingguidelinethathelpsyoumaketherightdecisionwhereitreallymatters: Evaluation,selection,installation,operationandtestingofyourweighingsystem.AdvantagesofusingGWP®anditssolutionsare:

•Adviceonhowtochoosethecorrectbalanceforyourrequirements•Guidanceonhandlingandmaintenanceofthebalancetoalwaysachieve accurateresults

•Recommendationsfortherighttestingscenarios•Reducedcostsandsecureaudits

Routine Testing – YourInsuranceforExactResults

Routine testing verifies your balance is performing within specifications and ensures valid results.

Common Problems and ExplanationsProblem:Weightdisplayofaweighingsampledriftsinonedirection.Possible Explanation: Temperatureinfluencesonthebalance

Problem: WeightdisplayofaweighingsamplepermanentlydriftsinonedirectionPossible Explanation: Moisturegainorlossbytheweighingsample

Problem: Eachweighingshowsadifferentresult.Theweightdisplayisunstable.Repeatabil-ityoftheresultispoor.Possible Explanation: Electrostaticallychargedweighingsamplesorvessels

Problem: Weightofaweighingsampledependsonitspositionontheweighingpan.Repeat-abilityoftheresultispoor,butdisplayisstablePossible Explanation: Magneticweighingsamplesorvessels

Problem: More(true)massonplatformthanisindicatedbythebalancePossible Explanation: Air buoyancy,temperaturediffer-ences,electrostaticcharging

Problem: TheweighingvaluesaredifferentwhentheweighingheightchangesPossible Explanation: Interplayofgravitationalforceandcentrifugalacceleration

Scho

ol e

xper

imen

ts

Natural science laws experience “live” – learn easily

ABC

of T

itrat

ion

ABC of Titration in Theory and Practice

Titration Theory

Weighing Tips and Tricks Poster•Avoidcommonlymadeerrors•Improveyourweighingskills•Getsomekeytipsandtricks

pH Tips and Tricks in Life Science •ImproveyourpHmeasurements•SeehowTRIScanaffectpHelectrodes•Covertheimportanceoftemperatureforaccurate

pH measure

ABC of Titration Guide•GetsomebestpracticesinpotentiometricandKarl

Fischer titrations•Avoiderrors•Getmoreconsistentresults

www.mt.com/basic-lab

Benefit now!Download the above guides and posters www.mt.com/basic-lab