stratasync dsam 24 hour pop report - amazon s3 · pop reporting pop reports units of measure below...

19
Page 1 of 19 StrataSync POP Reporting StrataSync DSAM 24 Hour POP Report Thursday, January 28, 2016

Upload: others

Post on 23-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 1 of 19

StrataSync

POP Reporting

StrataSync

DSAM 24 Hour POP Report

Thursday, January 28, 2016

Page 2: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 2 of 19

StrataSync

POP Reporting

Table of Contents

StrataSync ................................................................................................................................................... 1

POP Reporting ............................................................................................................................................ 1

Table of Contents ........................................................................................................................................ 2

Introduction ................................................................................................................................................. 3

POP Test Configuration – Location File, Channel Plan, Limit Plan .......................................................... 4

POP Reports Limits .................................................................................................................................... 6

POP Default Report Limits ..................................................................................................................... 7

POP Reports Units of Measure ................................................................................................................... 8

Executing POP Tests on DSAM ................................................................................................................. 9

Generating POP Reports ........................................................................................................................... 12

Example POP Report - HTML ................................................................................................................. 13

Example POP Report - Excel .................................................................................................................... 15

APPENDIX A. DSAM 24 Hour POP Report Details............................................................................... 16

When does a 24 hour POP report fails? ................................................................................................ 16

APPENDIX B. Summary of FCC Proof of Performance Test ................................................................. 18

Overview of FCC Proof of Performance Test Requirements ............................................................... 18

Who must run the tests? ........................................................................................................................ 18

When do the tests need to be run? ........................................................................................................ 18

How many channels need to be tested? ................................................................................................ 18

How are the test channels selected? ...................................................................................................... 18

How many test sites do we need? ......................................................................................................... 18

Where, in the system, are the tests conducted? ..................................................................................... 19

Are there specified procedures for each test? ....................................................................................... 19

Where do we send the test results? ....................................................................................................... 19

What happens if we don't pass? ............................................................................................................ 19

Where do I go for more information on Proof Testing? ....................................................................... 19

Page 3: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 3 of 19

StrataSync

POP Reporting

Introduction

The term Proof of Performance tests may have different interpretations depending on your

geographic locality. In North America, Proof of Performance tests can tie directly to testing mandated

by the Federal Communications Commission (FCC); however, in other localities Proof of Performance

test may simply refer to having the ability to run test over various times and physical constraints such as

weather and/or temperature. The DSAM meter can perform Proof of Performance tests immediately or

over any set of time intervals that you desire. This is particularly useful when you are running the 24-

Hour test required by the FCC in the US and by other international governing bodies.

It is a fact that all cable systems need to be able to consistently check measurements in their

network during various times and over a wide temperature range. The DSAM together with StrataSync

provides a seamless way for operators to conduct Proof of Performance. This document will provide key

step-by-step instructions on setting up StrataSync to work in conjunction with the DSAM to deliver the

Proof of Performance functionality.

Page 4: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 4 of 19

StrataSync

POP Reporting

POP Test Configuration – Location File, Channel Plan, Limit Plan

Proof of Performance testing is configured using StrataSync. A typical Location File configuration

for performing Proof of Performance test is shown below. These same steps are similar when

configuring the Channel Plan and Limit Plan configurations.

1. Select Assets -> Manage Templates -> DSAM

2. Select the Location File link in the left panel in the Global Archive section (or you can chose a

named Template instead).

3. Create a new Proof Location File by clicking on the + New Location File link.

4. Customize the Proof of Performance configuration file name, Initial Values and/or Field Names.

Page 5: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 5 of 19

StrataSync

POP Reporting

5. Save the Location File.

6. On the Global Archive list page, select that Location File, open the Actions dropdown and select

Deploy.

7. Select the desired DSAMs to deploy to. Press Next. Confirm your selections and press Deploy.

8. Synchronize selected meters with the StrataSync Server.

Page 6: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 6 of 19

StrataSync

POP Reporting

POP Reports Limits

Below are the editable limits, StrataSync applies these modified limits while performing the DSAM 24

hour POP report.

On the top of your browser window, select “System Settings”. These instructions assume you have

permissions to view/edit these settings. From the left panel, select “DSAM 24 Hour Report Limits.

This page allows a user to edit POP FCC limits that are used in validating POP tests. Click on “Done” to

save changes to any edited fields. To restore default FCC limits, click on “Restore To Default” button at

the top of page followed by click on the “Done” button to save changes.

A description of the “Analog Delta Video Offset” and “Digital Delta Video Offset” can be found in

Appendix A.

Remaining limits that are visible after scrolling:

Page 7: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 7 of 19

StrataSync

POP Reporting

POP Default Report Limits

Below table lists the default POP limit values used by StrataSync.

Limit Name Limit Value Comment

24 Hour Deviation 8 dB

Maximum Adjacent Channel 3 dB

Maximum Analog Delta Video 10 dB

Analog Delta Video Offset 1 dB For bandwidth > 300 MHz, Offset

will be added to Maximum Analog

Delta Video limit for each additional

100 MHz above 300 MHz

Maximum Digital Delta Video 10 dB

Digital Delta Video Offset 1 dB For bandwidth > 300 MHz, Offset

will be added to Maximum Analog

Delta Video limit for each additional

100 MHz above 300 MHz

Minimum Video Level 3 dBmV Video level for analog channels.

Minimum Digital Level -10 dBmV Video level for digital/DOCSIS

channels.

Minimum Standard Video/Aural Carrier

Level Delta

10 dB

Maximum Standard Video/Aural Carrier

Level Delta

17 dB

Page 8: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 8 of 19

StrataSync

POP Reporting

POP Reports Units of Measure

Below are the editable units of measure, StrataSync applies these while creating the DSAM 24 hour

POP report. If your StrataSync user has ever visited the “My Preferences” -> “Measurement Units”

page and pressed “Done”, then that data will override the “System Settings” values.

On the top of your browser window, select “My Preferences”. From the left panel, select “Measurement

Units. Click on “Done” to save changes to any edited fields.

On the top of your browser window, select “System Settings”. These instructions assume you have

permissions to view/edit these settings. From the left panel, select “Measurement Units. Click on

“Done” to save changes to any edited fields.

Page 9: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 9 of 19

StrataSync

POP Reporting

Executing POP Tests on DSAM

Key steps in running the Proof of Performance test on the DSAM include the following:

1. Press the AutoTest button on the DSAM

2. Scroll down to and select “proof of performance”

3. Configure the Proof of Performance Test

Channel Plan, Limit Plan, Filename to save to, Ambient Temp, etc.

Name entered in “Filename to save to” field will become folder name for the proof of

performance files.

4. Configure Proof of Performance Test Scheduling via Scheduled Soft Key

Page 10: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 10 of 19

StrataSync

POP Reporting

Meter shuts down until time of Auto Test and wakes itself

Input start time, interval, date, etc...

4 sessions over a 24 hour period

5. Input location data (i.e. Location, Location Type, Area, Trunk, AMP ID …)

6. Start Proof of Performance Test

7. Monitor progress and Review Results.

Page 11: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 11 of 19

StrataSync

POP Reporting

8. Results are saved in an appropriately named folder as entered in “Filename to save to” field in

step3.

9. Sync the DSAM to the StrataSync Server to transfer test results to the server

Page 12: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 12 of 19

StrataSync

POP Reporting

Generating POP Reports

1) Retrieve the appropriate test data list. This is available in 2 methods:

a) When 1 asset took all 4 POP test data files:

i. Select Asset -> Asset List from the top menu.

ii. Find the DSAM asset that took all of the results

iii. Double click that asset row to get the asset details page.

iv. In the right panel named “Most Recent Test Data”, click the link “Create DSAM 24

Hour Report”

b) Otherwise:

i. Select Test Data -> Test Data List

ii. Under the Asset Type column header, click the empty box and select the “DSAM”

asset type and “Apply”.

Page 13: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 13 of 19

StrataSync

POP Reporting

iii. Under the “Data Type” column header, click the empty box, type “Pro” and select the

“Proof Of Performance” data type and click the test data list (Optionally select one of

the following instead: TechComplete Home Certification Test, AutoTest - Video

Channels or AutoTest – Combo).

2) Select exactly 4 files from the test data list by checking the checkbox in the left column of a

desired row. Selections can be made on multiple pages.

3) Click the “Actions” dropdown and select “Reports” -> “DSAM 24 hour report”

Example POP Report - HTML

Page 14: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 14 of 19

StrataSync

POP Reporting

Page 15: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 15 of 19

StrataSync

POP Reporting

Example POP Report - Excel

You may also Print or Export-to-Excel the results. When exporting to Excel, it is

recommended that you “open” the results in Excel (which does a conversion from HTML to

Excel format) and then save to the XLS or CSV formats as desired.

Snapshot of 24 hour POP report in Excel

Page 16: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 16 of 19

StrataSync

POP Reporting

APPENDIX A. DSAM 24 Hour POP Report Details

When does a 24 hour POP report fails?

24 hour POP report status is “fail” if:

1. Channel type or frequency does not match among measurements

2. Missing channels in measurement files

3. 4 measurement files are not used

4. If measurements are not with in 6, 12, and 18 hours from the 1st test (plus or minus 1 hour).

5. If 24 hour deviation is not with in 24 Hour Deviation Limit as set in POP Reports Settings

page. The default value is 8dB.

6. If Adjacent Visual Signal Level a.k.a Adjacent Channel is not with in Maximum Adjacent

Channel limit as set in POP Reports Settings page. The default value is 3dB. This 3dB is

applicable for both analog and digital channels.

7. If there are pair of analog (TV or Dual) channels which happen to be with in 6 MHz

frequency separation and there is no adjacent channel data measured.

8. If Minimum Visual Signal Level is less than Minimum Video Level Limit as set in POP

Reports Settings page. The default value is 3dBmV.

9. If Minimum Digital Level is less than Minimum digital Level Limit as set in POP Reports

Settings page. The default value is -10dBmV.

10. If Aural Carrier Level a.k.a V/A Level is not in between MINIMUM STANNDARD

VIDEO/AURAL CARRIER LEVEL DELTA and MAXIMUM STANDARD VIDEO/AURAL CARRIER

LEVEL DELTA. Default min and max are 10dB and 17 dB respectively.

11. If Analog Delta Video is not with in Maximum Analog Delta Video Limit.

Maximum Analog Delta Video Limit is calculated as follows using Maximum Analog Delta

Video and Analog Delta Video Offset as set in POP reports settings page:

If bandwidth > 300MHz then

Maximum Analog Delta Video Limit = Maximum Analog Delta Video + Analog Delta

Video Offset for each additional 100MHz above 300 MHz.

else

Maximum Analog Delta Video Limit = Maximum Analog Delta Video

The default limit and offset are 10dB and 1dB respectively.

12. If Digital Delta Video is not with in Maximum Digital Delta Video Limit.

Maximum Digital Delta Video Limit is calculated as follows using Maximum Digital Delta

Video andDigital Delta Video Offset as set in POP reports settings page:

If bandwidth > 300MHz then

Page 17: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 17 of 19

StrataSync

POP Reporting

Maximum Digital Delta Video Limit = Maximum Digital Delta Video + Digital Delta

Video Offset for each additional 100MHz above 300 MHz.

else

Maximum Digital Delta Video Limit = Maximum Digital Delta Video

Note: - If there are no analog channels i.e. only digital channels are present or if there exists analog

channels that do not fall in 6 MHz separation with analog channel next to it, and if there is no Adjacent

Visual Signal data for any channel then Adjacent Visual Signal status is displayed as “No data” and it is

not taken into consideration for the overall report status calculation.

Page 18: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 18 of 19

StrataSync

POP Reporting

APPENDIX B. Summary of FCC Proof of Performance Test

Overview of FCC Proof of Performance Test Requirements

For details of the Proof of Performance test requirements, refer to the Code of Federal Regulations (CFR)

47, part 76. This book is available from the US Government Printing Office, Mail Stop: SSOP,

Washington, DC 20402-9328. Many cities in the US have US Government Printing Office stores that

sell Government publications directly to the public.

Who must run the tests?

All systems with 1000 or more subscribers. Smaller systems are required to comply with the Cumulative

Leakage Index requirements (including quarterly measurements) but are not normally required to

demonstrate proof of performance of the other technical standards. The technical standards are expected

to be met by all systems -- but small systems don't need to prove it.

When do the tests need to be run?

Most tests need to be conducted "at least twice each calendar year (at intervals not to exceed seven

months)". The "24 hour" tests "shall be measured and recorded, along with the date and time of the

measurement, once every six hours (at intervals of not less than five hours nor more than seven hours

after the previous measurement), to include the warmest and the coldest times, during a 24 hour period

in January or February and in July or August".

The 24 hour test is the only one required during those particular months.

The color tests (Chrominance to Luminance Delay Inequality, Differential Gain, and Differential Phase),

need to be conducted at least triennially (once every three years).

How many channels need to be tested?

Many tests are required on all "NTSC or similar video channels" of the system. Other tests are required

"a minimum of four (4) channels plus one additional channel for every 100 MHz, or fraction thereof, of

cable distribution system upper frequency limit (e.g. 5 channels for cable system upper frequency limit

of 101 to 216 MHz; 6 channels for cable television systems with a cable distribution system upper

frequency limit of 217-300 MHz; 7 channels for cable television systems with a cable distribution upper

frequency to 300 to 400 MHz, etc.)."

All channels are required to meet all of the technical standards. However, for certain of the technical

standards, you only need to demonstrate "proof of performance" on a sampling of the channels...

How are the test channels selected?

"The channels selected must be representative of all the channels within the cable television system."

Generally, systems select channels from across the system's spectrum.

How many test sites do we need?

For systems from 1000 to 12,500 subscribers, tests "...... shall include measurements taken at six (6)

widely separated points. However, within each cable system, one additional test point shall be added for

every additional 12,500 subscribers or fraction thereof (e.g., 7 test points if 12,501 to 25,000 subscribers,

etc.). "

Also, there must be at least one test point "for each portion of the cable system served by a technically

integrated microwave hub".

Page 19: StrataSync DSAM 24 Hour POP Report - Amazon S3 · POP Reporting POP Reports Units of Measure Below are the editable units of measure, StrataSync applies these while creating the DSAM

Page 19 of 19

StrataSync

POP Reporting

Note that this does not mean a test point for each fiber node.

Where, in the system, are the tests conducted?

Test points "shall be balanced to represent all geographic areas served by the cable system. At least one-

third of the test points shall be representative of subscriber terminals most distant from the system input

and from each microwave receiver (if microwave transmissions are employed), in terms of cable length".

Measurements may be made at convenient monitoring points in the system so long as the data reflects

system performance for nearby subscribers.

Some measurements (visual signal level and 24 hour tests) are required to be measured "at the end of a

30 meter (100 foot) cable drop that is connected to the subscriber tap, ..." Usually, all tests in the field

are conducted at the end of a 100 foot drop cable. The 100 foot drop cable simulates typical drops

provide to homes. For tests at the output of a set-top converter, connect the converter to the end of the

drop cable.

Are there specified procedures for each test?

In general, no. However, good engineering practices are to be used for all tests. For some measurements,

the rules refer to documents such as the "NCTA Recommended Practices for Measurements on Cable

Television Systems, 2nd edition, November 1989". A review of that document is an excellent starting

point.

Of course, measurement equipment and techniques are continually evolving. There is a lot of test

equipment available today that make the tests much easier than some of the procedures described in the

NCTA documents. Before you decide to use any procedure, you should of course, have a thorough

understanding of the test requirements and the algorithms used by your test gear. Do not blindly trust

automated test gear simply because it provides "numbers"!

Where do we send the test results?

Unless told otherwise by the FCC or your franchise authorities, you simply keep the data on file for at

least five years. The test data is required to be made available to the FCC or local franchise authorities

upon request.

What happens if we don't pass?

Tests have been run on over 50 systems, many of them multiple times. So far, one system has "passed"

all the requirements (it passed one of the two times in which tests were run on it).

Given the complexity of today's cable systems, the thousands of mechanical connections involved the

number of back hoes and other rodents in our society; something, somewhere, is likely to be broken at

any given point in time.

The most important thing is to run the tests, find the problems, fix them, and keep a log of the whole

process.

Of course, carrier leakage problems should be addressed as soon as they are discovered. Authorities tend

to frown when aircraft start honing in on bad splices.

Where do I go for more information on Proof Testing?

http://www.fcc.gov/mb/engineering/601.html

http://www.fcc.gov/mb/engineering/604.html