TRANSCRIPT

Page 1: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

Structured Cabling Systems

Page 2: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

S T R U C T U R E D C A B L I N G S Y S T E M S

C O P P E R S Y S T E M S Page

Augmented Category 6 Systems Page

Category 7 Systems Page

Category 6 Systems Page

Category 5e Systems Page

Category 3 Systems Page

Copper System Accessories Page

S M A R T PAT C H I N T E L L I G E N T I N F R A S T R U C T U R E M A N A G E M E N T Page

Scanning Hardware Page

Copper Patch Panels Page

Copper Patch Cords Page

Fibre Patch Panels Page

Fibre Patch Cords Page

Components Page

Software Components Page

O P T I C A L S Y S T E M S Page

Tight Buffered Cables Page

Distribution Cable ...................................................................................................................................................Page

Breakout and Patch Cable ........................................................................................................................Page

Loose Tube Cables Page

Unitube Cable ................................................................................................................................................................Page

Multi Loose Tube Cable .................................................................................................................................Page

Special Environment Cables Page

Fire Survival Cable ..................................................................................................................................................Page

Optical Components Page

Pigtails and Patch Cords ..............................................................................................................................Page

Optical Patch Panels ...........................................................................................................................................Page

Connectors and Adaptors ........................................................................................................................Page

Air Blown Fibre Page

D ATA C E N T R E C A B I N E T S & R A C K S Page

High Density Fibre Cabinet Page

High Density Copper Cabinet Page

High Density Distribution Equipment Rack Page

High Density Cable Management Rack Page

Pre-terminated Fibre Solutions Page

5

7

22

25

42

58

62

74

83

84

85

87

88

93

114

115

116

117

123

126

134

147

156

157

159

161

163

164

166

167

168

169

170

171

172

Page 3: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

2

Our Business

Brand-Rex is a leading global supplier of

structured cabling systems for data networks,

and is a niche supplier of high performance

cables for extreme environment applications.

Brand-Rex provides complete cabling systems

that connect the IT equipment in our offices and

datacentres – from patch cords and wall outlets

seen in the office, to cable running under floors

and above ceilings, to connectivity panels that

interface with active equipment in the IT room.

Within vast datacentres, hosting huge amounts

of business-critical information, Brand-Rex offers

industry-leading, high-speed and high-density

solutions.

Our Company

Brand-Rex Limited was established in 1972,

in Glenrothes, Scotland, where the company’s

head office remains today. Brand-Rex also has

10 global offices, a presence in over 50 countries

worldwide and over 300 employees supporting

a truly global customer base.

The core technologies provided by Brand-Rex

include copper-based cabling systems, fibre

optic cabling systems (including a unique

air-blown fibre system) and an Intelligent

Infrastructure & Management Solution that

delivers full visibility and management

capability to end user clients.

Brand-Rex solutions are delivered to market

through a network of high-calibre service

and installation partners. The company uses

distribution specialists and an army of trained,

accredited installers who ensure that the correct

system solutions are deployed and installed

every time. The company also engages with end

users and their consultants directly to ensure

the best mutual understanding of needs and

capabilities is achieved.

Technology Leader

With an experienced, dedicated and expert

design and development team, Brand-Rex is

a strong and capable force that continues to

challenge industry conventions.

Through sophisticated modelling techniques

and advanced test laboratories, Brand-Rex

has been able to develop some of the most

sophisticated cable and connectivity

solutions available.

The New Product Development process that

Brand-Rex deploys is a rigorous one. Among

other issues this process entails technology

forecasting, customer clinics, competitor

analysis, cross-functional teams and, of course,

continued investment.

Brand-Rex’s technical expertise is further

evidenced through representation on standards

committees, products that stand up to

3rd party scrutiny, a significant patents portfolio,

industry-recognised training courses and

professional engagement with the industry’s

leading consultants.

Technical Service and Support

Brand-Rex has a dedicated and experienced

technical support team that is led from head

office and located throughout the world to

support our global customers.

Page 4: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

3

This team’s purpose is to deliver training and

technical support to installation partners

and end users in the design, deployment and

commissioning of their high-performance

data networks.

The rigid training and accreditation of installers,

combined with validation of installation test

results, allows Brand-Rex to offer end users

a 25-year product and lifetime application

warranty that remains one of the best

in the industry.

Best in Class Manufacturing

Brand-Rex has long been known for its high

quality manufacturing capabilities.

Having declared a commitment to maintaining

cable production within the UK, Brand-Rex

has invested £10 million in the creation of a

new data cabling factory at the Glenrothes

site enabling the company to compete on the

global stage against manufacturers in lower cost

countries. The investment program has resulted

in a factory that can rival any in the world.

This manufacturing facility and the ‘Speciality

Cable’ plant at Leigh, near Manchester, both

hold ISO 9001:2008 quality certification and

environment accreditation to ISO:14001:2004.

Customer Service - Brand-Rex has a mission:

‘To be a market leader in Customer Service.’

“So, whether it’s the ease of gaining information,

the way that we talk to our customers, our

ability to provide the right products when

required, or how flexible we are to your own

special needs, Brand-Rex is determined

to surpass your expectations. As members of

The Institute of Customer Service, we know

the benchmark that we must surpass. We are

implementing some rigorous assessment and

training within every area of our business to

ensure that no matter what we do, we beat

your expectations.

We think you will notice the difference.”

C O M PA N Y P R O F I L E

Brand-Rex - A Carbon Neutral Company

Brand-Rex is dedicated to reducing its impact

on the environment and as demonstrated our

commitment by reaching Carbon Neutral status

for our organisational and operational activities.

Working with the market-leading adviser on

energy and emissions reduction: CAMCO Centre

for Carbon Management, we measured our

organisational carbon footprint in line with ISO

14064, which includes the compulsory scope 1

and 2 emissions and voluntary scope 3 emissions.

As one of the leading cable suppliers in the world

we understand the production of cable inevitably

means high levels of electricity use, that’s why we

are committed to continually reducing our impact

on the environment by utilising sustainable

energy sources and materials.

Page 5: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category
Page 6: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

5

Structured cabling systems of today and in the future structured

cabling world have to cope with the ever-growing demands of

greater and greater bandwidth absorption within the local area

network. All Brand-Rex copper systems provide the IT Manager

with a complete open cabling system from the point of entry,

to building distribution, to floor distribution, to wiring closet,

to wall outlets, and ultimately to the desk.

The Brand-Rex product range is system based, with each system

containing full connectivity comprising of cable, patch panels,

wall outlets and patch cords supporting all LAN applications

including VoIP and Power over Ethernet

A premier grade cabling system needs standards compliant

components, and that is what Brand-Rex systems offer.

The proof of this is in the overall link and channel performance,

which is the only parameter that the transmission equipment

is going to see. GigaPlus, Cat6Plus and 10GPlus components

are engineered to achieve guaranteed channel performance.

Brand-Rex Copper Systems Support all the Protocols defined

in the international standards including:

(IEEE 802.3an)

Third party independent certificates of compliance are available

for component and channel performance from 3P Testing and

GHMT Laboratories GmbH for GigaPlus, Cat6Plus, 10GPlus

and U-MediaPlus.

Augmented Category 6.

50173-1 and Class FA.

C O P P E R S Y S T E M S

Page 7: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

6

CatAC6

Cat5e

Cat6

Cat7

P R O D U C T D E S C R I P T O R S E X P L A I N E D

Cable Properties

A simple legend system has been adopted throughout this brochure. The detail listed here provides descriptions of the symbols used.

These symbols describe the physical properties of the cable, and where cables are to be used.

Horizontal CableSuitable for installation in the

horizontal plane of a structured

wiring system.

This product is available with an

IEC 60332-3-24 flammability rating.

This product is available with an

IEC 60332-1 flammability rating.

Riser CableSuitable for installation in the

risers and backbone areas within

a structured wiring system.

UnshieldedThe cable is unshielded.

Foiled Pairs A PET coated Aluminium foil is

applied around the individual pairs.

Overall FoilA PET coated Aluminium foil

is applied around the 4 pair

core construction.

Overall TCW BraidThe core construction

is surrounded by an overall

TCW braid.

Category 6

Communications RoomSuitable for use in a communications

room or consolidation point.

Voice over IPSuitable for VoIP applications on

enabled networks.

Power over EthernetSuitable for Power over Ethernet

applications on enabled networks.

Internal System

General Office OutletSuitable for general offfice use.

Page 8: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

77

Waking up to a new era

10 Gigabit Ethernet over copper cabling

systems have been heralded as the greatest

technological revolution in networking

since the birth of Ethernet.

The engineering science dedicated to

overcoming the boundaries of convention

should not be underestimated. Brand-Rex

has dedicated a team of design engineers,

technologists and laboratory technicians

to developing the highest performance

10 Gigabit Ethernet solution on the

market today.

High performance businesses need

high performance networks

The use of increasingly sophisticated

IT applications in modern, competitive

business has driven the growth of Ethernet.

What value is an enterprise application if

the network hardware cannot support it?

Whether your business uses demanding

graphics based design packages, data

hungry finance systems or emerging

multi-media communication tools, they

have one thing in common, a need for:

Greater bandwidth

Maximum transmission reliability

Life long quality of operation

Resilience against environmental

challenges

10 Gigabit Ethernet provides the next

standard platform that will allow the

continued growth of high performance

business applications. Powerful IT

networks, able to deliver the new

10GBASE-T protocol, require phenomenal

processing power within active network

switching and routing hardware.

Such active hardware commands

a very high price.

Yet this investment is pointless unless

supported by an equally sophisticated

cabling system. It is vital that you can

trust the claims of any 10 Gigabit Ethernet

cabling system since the choices made

today will impact the business applications

of tomorrow.

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Page 9: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

8

PRODUCT DESCRIPTION

The Brand-Rex 10GPlus product set is a premium quality, high performance, future proof, cabling system. 10GPlus is classified

as an Augmented Category 6 and Class EA product set which is fully backward compatible to Category 6 (Class E) and Category 5e

(Class D) solutions.

It is a product set which is designed to be compliant with the new IEC Class EA and Augmented Category 6 standards, ready

for the new application from IEEE, 10GBASE-T. The cabling system is available in screened and unscreened solutions, however

screened products are recommended because they are more robust against against electromagnetic noise and have improved

alien crosstalk performance.

Channel Performance

Frequency (MHz)

Insertion Loss (dB / 100m)

NEXT (dB)

PSNEXT (dB)

ELFEXT (dB / 100m)

PSELFEXT (dB / 100m)

Return Loss (dB / 100m)

ACR-N (dB / 100m)

PSACR-N (dB / 100m)

Channel Performance of 10GPlus

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

1 4 10 16 100 250 300 400

Spec

Typical

Spec

Typical

Spec

Typical

Spec

Typical

Spec

Typical

Spec

Typical

Typical

Typical

4.0

2.1

65.0

78.8

62.0

77.7

63.3

72.0

60.3

70.0

19.0

23.0

76.6

75.6

4.1

4.0

63.0

69.3

60.5

67.9

51.2

60.0

48.2

58.0

19.0

23.0

65.3

63.9

6.4

6.3

56.6

62.9

54.0

61.3

43.3

52.0

40.3

50.0

19.0

23.0

56.7

55.0

8.1

7.9

53.2

59.7

50.6

57.9

39.2

47.9

36.2

45.9

18.0

22.0

51.7

49.9

20.8

20.4

39.9

46.6

37.1

42.2

23.3

32.0

20.3

30.0

12.0

16.0

26.3

23.9

33.8

33.1

33.1

40.0

30.2

37.2

15.3

24.0

12.3

22.0

8.0

12.0

6.8

4.1

37.3

36.6

31.7

38.6

28.8

35.8

13.7

22.5

10.7

20.5

8.0

12.0

2.1

-0.8

43.6

42.8

29.6

36.5

26.6

33.6

11.2

20.0

8.2

18.0

8.0

12.0

-6.3

-9.2

500

49.3

48.4

27.9

34.9

24.8

31.8

9.3

18.0

6.3

16.0

8.0

12.0

-13.5

-16.5

Guaranteed

Headroom to Class E

6%

6

7.5

8

9

3

9

10

2%

6

7

9

10

4

6

7

Typical Headroom

to Class EA

Unshielded Systems

Frequency (MHz) 4 10 16 100 250 300 400

PSANEXT (dB )Spec

Typical

PSAACR-F (dB)Spec

Typical

67.0

83.0

67.0

82.0

67.0

77.0

65.0

70.0

67.0

73.0

57.0

62.0

67.0

71.0

52.9

57.9

60.0

63.0

37.0

42.0

54.0

57.0

29.0

34.0

52.8

55.8

27.5

32.5

51.0

54.0

25.0

30.0

500

49.5

52.5

23.0

28.0

-

-

3

5

Guaranteed

Headroom

to Class E

Typical Headroom

to Class EA

Frequency (MHz) 1 4 10 16 100 250 300 400

PSANEXT (dB )Spec

Typical

PSAACR-F (dB)Spec

Typical

67.0

90.0

67.0

87.0

67.0

84.0

65.0

75.0

67.0

80.0

57.0

67.0

67.0

78.0

52.9

62.9

60.0

70.0

37.0

47.0

54.0

64.0

29.0

39.0

52.8

62.8

27.5

37.5

51.0

61.0

25.0

35.0

500

49.5

59.5

23.0

33.0

-

-

10

10

Shielded Systems

Guaranteed

Headroom

to Class E

Typical Headroom

to Class EA

Central Computer Room Floor Distribution

Building

Riser

Outlet

2,3 or 4 Connector Channel

Page 10: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

9

AC6500MHz

Brand-Rex Copper Cables - 10GPlusΩ

Cable Standards

The cable is compliant with:

standard EN 50288-11-1

The cable is fully backwards compatible with Category 5

and Category 6 systems

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

Category 6 cable to support 10 Gigabit

Ethernet protocol for installation in horizontal

and backbone applications.

PRODUCT PERFORMANCE

Core

Conductor: 23 AWG Plain Annealed

Copper Wire

Insulation: Polyolefin

Diameter: 1.06mm Nominal

Pair: 2 of the above cores

Pair Colour: Blue - White, Orange - White

Green - White, Brown - White

Final Assembly

Cable: 4 of the above pairs cabled

together around a cross filler

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0C to 50C

Temp - Operation: -20C to 75C

Max Tensile Load: 10kg per cable

Min Bend Radius: 8 x Effective Diameter

(installation)

Min Bend - Operation: 4 x Effective

Diameter (operation)

Halogen Free cable types (LSHF) meet IEC 60754-2

and IEC 61034

Max 19Ω

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500 MΩ.km @ 100-500 V test voltage

Ω @ 100Mhz

Min 40dB

Max 19Ω

0.5%

100% in process test

>5 GΩ.km

Ω @100Mhz

56dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

Return Loss

Insertion Loss

NEXT

PSNEXT

ELFEXT

PSELFEXT

PSANEXT

PSAELFEXT

Characteristic Typical Headroom vs (250MHz) Typical Headroom vs AC6 (500MHz)

5dB

6%

10dB

10dB

12dB

12dB

NA

NA

5dB

2%

10dB

20dB

12dB

12dB

5dB

6dB

Sheath

Cross Filler

23 AWG PACW

Polyolefin Insulation

* Power Sum Attenuation to Alien Crosstalk (near end) Ratio The Alien crosstalk performance of cables is assessed using a ‘6 round 1’ or ‘4 on a drum’ method.

PSACR-N @ 500MHz

PSAACR-N* @ 500MHz

Typical headroom on key S/N characteristics - for information only

NA

NA

0dB

13dB

Typical Headroom vs Cat6 (250MHz) Typical Headroom vs AC6 (500MHz)

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

AC6U-HF1-500VT

AC6U-HF1-1000VT

AC6U-HF3-500BU

AC6U-HF3-1000BU

500

1000

500

1000

LSHF

LSHF

Violet

Blue

8.5

8.5

79

81

0.32

0.42

IEC 60332-1-2

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Product Part Numbering

Page 11: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

1010

AC6500MHz

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

to support 10 Gigabit Ethernet protocol for

installation in horizontal and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 23 AWG Plain Annealed

Copper Wire

Insulation: Cellular Polyolefin

Diameter: 1.36mm Nominal

Pair: 2 of the above cores

Tape Screen: Individual pair wrapped with

aluminium polyester tape,

applied metal side out

Pair Colour: Blue-White, Orange-White,

Green-White, Brown-White

Final Assembly

Cable: 4 of the above shielded pairs

Drainwire: 0.5mm Tinned Annealed

Copper Wire

Tape Screen: Wrapped with aluminium

polyester tape,

applied metal side in

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Halogen Free cable types (LSHF) meet IEC 60754-2

and IEC 61034

Sheath

Polyolefin Insulation

23 AWG PACW

TACW Drainwire

Cable Standards

The cable is compliant with:

It is also designed to be compliant with EN50288-10-1

standards when it is published:

These cables are also fully backwards compatable with

Category 5 and Category 6 systems

* Power Sum Attenuation to Alien Crosstalk (near end) Ratio The Alien crosstalk performance of cables is assessed using a ‘6 round 1’ or ‘4 on a drum’ method.

Brand-Rex Copper Cables - 10GPlus

Return Loss

Insertion Loss

NEXT

PSNEXT

ELFEXT

PSELFEXT

PSANEXT

PSAELFEXT

Characteristic Typical Headroom vs Cat6 (250MHz) Typical Headroom vs AC6 (500MHz)

5dB

6%

20dB

20dB

15dB

15dB

NA

NA

5dB

2%

20dB

20dB

15dB

15dB

10dB

10dB

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ @ 100-500 V test voltage

Min 55 dB

0.5%

100% in process test

>5 GΩ.km

75 dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Transfer Impendance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

PSACR-N @ 500MHz

PSAACR-N* @ 500MHz

Typical headroom on key S/N characteristics - for information only

NA

NA

35dB

20dB

Typical Headroom vs Cat6 (250MHz) Typical Headroom vs AC6 (500MHz)

Product Part Numbering

500

1000

500

1000

500

1000

LSHF

LSHF

LSHF

Violet

Violet

Blue

0.13

0.26

0.15

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

7.20

14.5 x 7.2

7.6

51

102

60

Page 12: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

11

AC6500MHz

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

to support 10 Gigabit Ethernet protocol for

installation in horizontal and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 23 AWG Plain Annealed

Copper Wire

Insulation: Cellular Polyolefin

Diameter: 1.36mm Nominal

Pair: 2 of the above cores

Tape Screen: Individual pair wrapped with

aluminium polyester tape,

applied metal side out

Pair Colour: Blue-White, Orange-White,

Green-White, Brown-White

Final Assembly

Cable: 4 of the above shielded pairs

Braid Tinned Annealed Copper Wire

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Halogen Free cable types (LSHF) meet IEC 60754-2

and IEC 61034

Sheath

TACW Braid

Polyolefin Insulation

23 AWG PACWCable Standards

The cable is compliant with:

It is also designed to be compliant with EN50288-10-1

standards when it is published:

These cables are also fully backwards compatable with

Category 5 and Category 6 systems

* Power Sum Attenuation to Alien Crosstalk (near end) Ratio The Alien crosstalk performance of cables is assessed using a ‘6 round 1’ or ‘4 on a drum’ method.

Brand-Rex Copper Cables - 10GPlus

Return Loss

Insertion Loss

NEXT

PSNEXT

ELFEXT

PSELFEXT

PSANEXT

PSAELFEXT

Characteristic Typical Headroom vs Cat6 (250MHz) Typical Headroom vs AC6 (500MHz)

5dB

6%

20dB

20dB

15dB

15dB

NA

NA

5dB

2%

20dB

20dB

15dB

15dB

10dB

10dB

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ @ 100-500 V test voltage

Min 55 dB

0.5%

100% in process test

>5 GΩ.km

75 dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Transfer Impendance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

PSACR-N @ 500MHz

PSAACR-N* @ 500MHz

Typical headroom on key S/N characteristics - for information only

NA

NA

35dB

20dB

Typical Headroom vs Cat6 (250MHz) Typical Headroom vs AC6 (500MHz)

Product Part Numbering

500

1000

500

1000

500

1000

LSHF

LSHF

LSHF

Violet

Violet

Blue

0.11

0.24

0.12

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

7.20

14.5 x 7.2

7.6

51

102

60

Page 13: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

12

AC6500MHz

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

cable to support 10 Gigabit Ethernet protocol for

installation in horizontal and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 23 AWG Plain Annealed

Copper Wire

Insulation: Cellular Polyolefin

Diameter: 1.36mm Nominal

Pair: 2 of the above cores

Tape Screen: Individual pair wrapped with

aluminium polyester tape,

applied metal side out

Pair Colour: Blue-White, Orange-White,

Green-White, Brown-White

Final Assembly

Cable: 4 of the above shielded pairs

Drainwire: 0.5mm Tinned Annealed

Copper Wire

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Halogen Free cable types (LSHF) meet IEC 60754-2

and IEC 61034

Cable Standards

The cable is compliant with:

It is also designed to be compliant with EN50288-10-1

standards when it is published:

These cables are also fully backwards compatable with

Category 5 and Category 6 systems

* Power Sum Attenuation to Alien Crosstalk (near end) Ratio The Alien crosstalk performance of cables is assessed using a ‘6 round 1’ or ‘4 on a drum’ method.

Brand-Rex Copper Cables - 10GPlus

Return Loss

Insertion Loss

NEXT

PSNEXT

ELFEXT

PSELFEXT

PSANEXT

PSAELFEXT

Characteristic Typical Headroom vs Cat6 (250MHz) Typical Headroom vs AC6 (500MHz)

5dB

6%

20dB

20dB

15dB

15dB

NA

NA

5dB

2%

20dB

20dB

15dB

15dB

10dB

10dB

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ @ 100-500 V test voltage

Min 55 dB

0.5%

100% in process test

>5 GΩ.km

75 dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Transfer Impendance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

PSACR-N @ 500MHz

PSAACR-N* @ 500MHz

Typical headroom on key S/N characteristics - for information only

NA

NA

35dB

20dB

Typical Headroom vs Cat6 (250MHz) Typical Headroom vs AC6 (500MHz)

Product Part Numbering

500

1000

500

1000

LSHF

LSHF

Violet

Violet

0.12

0.25

IEC 60332-1-2

IEC 60332-1-2

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

7.1

14.3 x 7.1

51

102

Sheath

Polyolefin Insulation

23 AWG PACW

TACW Drainwire

Page 14: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

13

AC6500MHz

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Sheath

Polyolefin Insulation

26 AWG PACW

TACW Drainwire

Brand-Rex Copper Cables - 10GPlus Zone Cable

Cable Standards

The cable is compliant with:

ANSI/TIA/EIA568C

It is also designed to be compliant with EN50288-10-2

when it is published.

* Power Sum Attenuation to Alien Crosstalk (near end) Ratio The Alien crosstalk performance of cables is assessed using a ‘6 round 1’ or ‘4 on a drum’ method.

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Electrical Characteristics @ 20°c Specification Typical Performance

Return Loss

Insertion Loss

NEXT

PSNEXT

ELFEXT

PSELFEXT

PSA ACR-N

PSAACR-F

Characteristic Typical Headroom vs Cat6 (250MHz) Typical Headroom vs AC6 (500MHz)

PSACR @ 500MHz

PSAACR-N* @ 500MHz

Typical headroom on key S/N characteristics - for information only

Typical Headroom vs Cat6 (250MHz) Typical Headroom vs AC6 (500MHz)

Max. 2%

1.0kV dc or 0.7kV ac for 1 min

Max.

Max.

100 Ω ± 5 Ω @ 100MHz

26

0,5%

100% in process test

5dB

20%

20dB

20dB

15dB

15dB

NA

NA

5dB

20%

20dB

20dB

15dB

15dB

20dB

20dB

NA

NA

35dB

20dB

Product Part Numbering

AC6-DCZ-500VT

AC6-DCZ-1000VT

AC6-DCZ-500GY

AC6-DCZ-1000GY

500

1000

500

1000

LSHF

LSHF

Violet

Grey

5.6

5.4

33

33

0.08

0.08

IEC 60332-1-2

IEC 60332-1-2

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

cable to support 10 Gigabit Ethernet protocol

for use within the data centre environment.

PRODUCT PERFORMANCE

Core

Conductor: 26 AWG Plain Annealed

Copper Wire

Insulation: Cellular Polyolefin

Diameter: 1.0mm Nominal

Pair: 2 of the above cores

Tape Screen: Individual pair wrapped with

aluminium polyester tape

applied metal side out

Pair Colour: Blue-White, Orange-White

Green-White, Brown-White

Final Assembly

Cable: 4 of the above

shielded pairs

Drainwire: 0.5mm Tinned Annealed

Copper Wire

Sheath: LSHF compound

Mechanical and Environmental

Temp-Installation: 0°c to +50°c

Temp-Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation )

4 x Outer Diameter

(operation)

Halogen Free cable types (LSHF) meet IEC 60754-2

and IEC 61034

Page 15: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

14

AC6500MHz

MMCPCCHB001

MMCPCCHB002

MMCPCCHB003

MMCPCCHB004

MMCPCCHB005

MMCPCCHB006

Part Number

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

PRODUCT DESCRIPTION

The Brand-Rex Augmented Category 6 patch

cord is part of the Brand-Rex 10GPlus cabling

system. The 10GPlus cabling system is comprised

of high performance cables and connectivity

which not only provide a reliable platform for all of

today’s network applications, but is also designed

to future-proof networks for the emerging, new

higher speed protocols of tomorrow, such as

10GBASE-T. The 10GPlus system is classified as an

Augmented Category 6 and Class EA product set

that is fully backward compatible to Category 6

(Class E) and Category 5e (Class D) products.

Packaging

of 10 for standard stranded cords

Brand-Rex Copper Patch Cords - 10GPlusAugmented Category 6 Blade Server Patch Cords

G 26 AWG SFTP X Crossover

B Blade cord

HBS Solid

010 1 metre

020 2 metre

030 3 metre

050 5 metre

1 Red

4 Blue

5 Green

6 Yellow

8 Grey

A - Cord Type bbb - Cord Length cde - Colour Scheme

(c) Cable

-

-

-

-

8 Grey

(d) Boot 1

-

-

-

-

8 Grey

(e) Boot 2

F - Speciality Tag

Part Number Format

AC6-PC-A-bbb-cde-F

Additional colours on request

Product Part Numbering

RedLength Blue Green Yellow

AC6PCG010-188HB

AC6PCG020-188HB

AC6PCG030-188HB

AC6PCG050-188HB

AC6PCG010-488HB

AC6PCG020-488HB

AC6PCG030-488HB

AC6PCG050-488HB

AC6PCG010-588HB

AC6PCG020-588HB

AC6PCG030-588HB

AC6PCG050-588HB

AC6PCG010-688HB

AC6PCG020-688HB

AC6PCG030-688HB

AC6PCG050-688HB

AC6PCG010-888HB

AC6PCG020-888HB

AC6PCG030-888HB

AC6PCG050-888HB

Grey

26 AWG SFTP 1.0m

26 AWG SFTP - 2.0m

26 AWG SFTP - 3.0m

26 AWG SFTP - 5.0m

Non standard colour and length options are available to order on request.

Additional lengths on request

Note:- Boots are only available in Slate Grey. If boot colouring is required, a Retrofit

coloured boot clip can be purchased separately.

(Brand-Rex ref:-MMCPCCHBz Where z = 1= Red, 4 = Blue 5 = Green 6 =Yellow)

Shielded Patch Cord Clip – Red

Shielded Patch Cord Clip – Black

Shielded Patch Cord Clip – White

Shielded Patch Cord Clip – Blue

Shielded Patch Cord Clip – Green

Shielded Patch Cord Clip – Yellow

100

100

100

100

100

100

Description Qty

Page 16: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

15

AC6500MHzAC6500MHz

44.45

PRODUCT DESCRIPTION

The Brand-Rex Augmented Category 6

Snap-In-Jack panel is part of the Brand-Rex

10GPlus cabling system. The 10GPlus cabling

system is comprised of high performance cables

and connectivity which not only provide a reliable

platform for all of today’s network applications,

but are also designed to future proof networks

for the emerging, new, higher speed protocols

of tomorrow, such as 10GBASE-T. The 10GPlus

system is classified as an Augmented Category 6

and Class EA product set that is fully backwards

compatible to Category 6 (Class E) and Category

5e (Class D) products.

Packaging

individually packaged in a cardboard box

Installation

shielded & unshielded jacks

Mechanical Specifications

Dimensions

Material Data

high quality 1.5mm powder coated steel

Brand-Rex Copper Connectivity - 10GPlusAugmented Category 6 Modular Panel

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Part NumberColour

Product Part Numbering

24 Port Modular Snap-in-jack Panel

24 Port Modular Snap-in-jack Panel

MMCPNLX24SIJ2M-B

MMCPNLX24SIJ8M-B

Black

Grey

Page 17: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

16

6250MHz

5e100MHz

AC6500MHz

482.60

44.40

110

Brand-Rex Copper Connectivity - 10GPlusAugmented Category 6 1U 24 Port Patch Panel

24 ports in 1U

True Augmented Category 6/Class EA

performance

Suitable for 10Gigabit Applications

Ideal for use in the datacentre

Removable plug and play modular cassettes

ideal for both on and off site termination

assembly

Integral cable management to provide

strain relief

Compatible with standard 19” racks and cabinets

Flexible solution - panel can be deployed in

either a conventional installation or the module

used as a consolidation point

Supplied with panel mounting accessory kit

PRODUCT DESCRIPTION

The 10GPlus 19” rack mounted 1U 24 port patch

Class EA performance and is ideal for datacentre

applications. The robust patch panel features

4 easy to remove shielded modular units each

comprising of 6 ports.

To assure optimum link performance the panel

has been designed with integrated rear cable

management to provide easy routing and

strain relief.

Ports are numerically identified and offer

maximum space for ease of port numbering

and panels are supplied with cable ties, panel

mounting kit and earth cable. All panels are also

backward compatible.

PRODUCT CHARACTERISTICS

Width: 19” (483mm)

Height: 1u (44.45mm)

Depth: 111mm

Outlet Style: Unkeyed RJ-45

Outlets: 24 ports

Colour: RAL 9005 Black or

RAL 7035 Grey

Punch down blocks: LSA style IDC

Conformance: Augmented Category 6

and Class EA

EN 50173-1

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Description Colour Part number

10GPlus 1U Shielded 24 Port Patch Panel

10GPlus 1U Shielded 24 Port Patch Panel

10GPlus Replacement Panel Module

AC6PNLF240K2M

AC6PNLF240K8M

AC6CPF060K

Black

Grey

Metallic

Page 18: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

17

482.60

21.80

110

6250MHz

5e100MHz

AC6500MHz

Brand-Rex Copper Connectivity - 10GPlusAugmented Category 6 Half U 24 Port Patch Panel

24 ports in a ½U space

True Augmented Category 6/Class EA

performance

Suitable for 10Gigabit Applications

Ideal for the datacentre and for server cabinets

where space is at a premium

Removable plug and play modular cassettes

ideal for both on and off site termination

assembly

Integral cable management to provide

strain relief

Compatible with standard 19” racks and cabinets

Flexible solution - panel can be deployed in

either a conventional installation or the module

used as a consolidation point

Supplied with panel mounting accessory kit

PRODUCT DESCRIPTION

The Brand-Rex 10GPlus ½U patch panel offers true

is ideal applications where space is at a premium

and a high density solution is required. The panel

features 4 easy to remove shielded modular units

each comprising of 6 ports.

All panels are backward compatible and offer

integrated cable management to provide strain

relief. Ports are numerically identified and offer

maximum space for ease of port numbering

and panels are supplied with cable ties, panel

mounting kit and earth cable.

PRODUCT CHARACTERISTICS

Width: 19” (483mm)

Height: ½ u (22mm)

Depth: 111mm

Outlet Style: Unkeyed RJ-45

Outlets: 24 ports

Colour: RAL 9005 Black or

RAL 7035 Grey

Punch down blocks: LSA style IDC

Conformance: Augmented Category 6

and Class EA

EN 50173-1

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Description Colour Part number

10GPlus ½U Shielded 24 Port Patch Panel

10GPlus ½U Shielded 24 Port Patch Panel

10GPlus Replacement Panel Module

AC6PNLF240K2H

AC6PNLF240K8H

AC6CPF060K

Black

Grey

Metallic

Page 19: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

18

93.1

107.2

20.5

6250MHz

5e100MHz

AC6500MHz

Brand-Rex Copper Connectivity - 10GPlusAugmented Category 6 Consolidation Point Module

6 way shielded module

True Augmented Category 6/Class EA

performance

Suitable for 10Gigabit Applications

For use in horizontal cabling applications

Low profile construction – ideal for use in false

Removable cover to protect from dust particles

Optional mounting bracket

PRODUCT DESCRIPTION

The Brand-Rex 10GPlus Consolidation Point

EA Performance and is as flexible solution, ideal

for use in the open office environment.

Each module comprises of 6 RJ45 ports and can

be supplied as a low profile stand alone module

or with mounting bracket. The mounting bracket

option allows for secure fixing to walls, ceilings

and under floors, it also features cable tie points

for added security.

The cover can easily be removed to gain access

to the LSA IDC’s for termination. An area on top

of the cover is available for port identification.

All modules are backward compatible for Cat5e

and Cat6 systems. The module base and cover

are made from a lightweight construction which

offers excellent shielding characteristics.

PRODUCT CHARACTERISTICS

Without mounting bracket

Width: 107.2mm

Height: 20.5mm

Depth: 93.1mm

With mounting bracket

Width: 132mm

Height: 28mm

Depth: 110mm

Outlet Style: Unkeyed RJ-45

Outlets: 6 ports

Colour: Metallic

Punch down blocks: LSA style IDC

Conformance: Augmented Category 6

and Class EA

EN 50173-1

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Description Colour Part number

10GPlus Consolidation Point Module - 6 Way

10GPlus Consolidation Point Module with mounting bracket - 6 Way

10GPlus 1U Patch Panel Chassis Only

10GPlus 1U Patch Panel Chassis Only

AC6CPF060K

AC6CPF060KM

AC6PNLC240K2H

AC6PNLC240K8H

AC6PNLC240K2M

AC6PNLC240K8M

Metallic

Metallic

Black

Grey

Black

Grey

Page 20: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

19

6250MHz

AC6500MHz

5e100MHz

PRODUCT DESCRIPTION

The 10GPlus Shielded Tool-free Snap-in-

Jack is easy and quick to install, its compact

construction and multiple cable-entry

options make it the most flexible product

of its type available. It is smaller and

shorter than traditional products, allowing

it to fit more comfortably into confined

spaces. The jack also features an adjustable

management element allowing for a rear,

top or side-entry cable termination.

Designed for use in all structured cabling

environments including the general office and

data centres, the jack can be installed in patch

panels, wall outlets and floor box modules

to provide a robust and versatile solution.

The 10GPlus system is an Augmented

Category 6 and Class EA solution set that is

fully backwards compatible to Cat6 (Class E)

and Cat5e (Class D) products. The jack is fully

compatible with all our UK and Continental

style faceplates and patch panel products.

Independent 3rd Party Certification (3P)

PRODUCT CHARACTERISTICS

Outlet Style: Shielded keystone type

with unkeyed RJ-45 ports

Cable Entry: Rear

Hole Plate Thickness: Up to 1.6mm

Body Material: Zinc, Nickel plated

Jack Contacts: 50μin (1.27μm) gold over

nickel plating

Punch Down Blocks: Tool-Free with push down

cable manager for wire

AWG 22-27 solid

Wire Terminations: Tool-Free with cap

IDC Contacts: Tin plated titanium copper

Conformance: Conforms to all of the

physical reliability

requirements defined in

the IEC 60603-7 series of

568 C set (including ‘over-

stress’ testing up to 2,500

insertion cycles with

a standard plug).

Also available in Category 6

Brand-Rex Copper Connectivity – 10GPlus Tool-free Jack Augmented Category 6 Shielded Tool-free Snap-in-Jack

Part Number

AC6JAKS000

Description

Augmented Category 6 Shielded Tool-free Jack

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Product Part Numbering

Qty per Pack

12

Page 21: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

20

AC6500MHz

5e100MHz

6250MHz

31

36

46.6

23.6

23

.62

5.9

PRODUCT DESCRIPTION

The Brand-Rex 10GPlus Snap-In-Jack offers

true Class EA component performance using

a patented contact array design. The 10GPlus

system is classified as an Augmented Category 6

and Class EA product set that is fully backwards

compatible to Category 6 (Class E) and Category 5e

(Class D) products. The jack is also fully compatible

with all our UK and Continental style faceplates

and products.

PRODUCT CHARACTERISTICS

Outlet Style: Unshielded and

shielded Keystone

type with RJ-45 ports

Cable Entry: Top and Rear

Hole Plate Thickness: Jack will clip into sheet

material with a thickness

of 1.6mm max.

Body Material: High impact

PBT UL94 - VO

Jack Contacts: 50μin (1.27μm) gold over

nickel plating

Punch Down Blocks: LSA style IDC

IDC Contacts: Phosphor Bronze

Conformance: Category 6A

& amm1

EN50173-1 : 2007

Brand-Rex Copper Connectivity - 10GPlus JacksAugmented Category 6 Snap-In-Jacks

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Part Number

Product Part Numbering

10GPlus Unshielded Snap-in-jack

10GPlus Unshielded Snap-in-jack

10GPlus Shielded Snap-in-jack

AC6JAKUOK2

AC6JAKUOK3

AC6JAKFOK2

Colour

Black

White

Metallic

Qty per Pack

12

12

12

Page 22: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

21

6250MHz

AC6500MHz

5e100MHz

A U G M E N T E D C AT E G O R Y 6 S Y S T E M S

Brand-Rex Copper Connectivity - 10GPlus JacksAugmented Category 6 Unshielded Tool-free Jack PRODUCT DESCRIPTION

When used within a channel the tool-free

jack provides an industry leading electrical

performance and is fully compatible with Brand-

Rex UK and continental UNI style faceplates and

products. The jacks come supplied in boxes of 12;

termination instructions are on the rear of the

box. No termination tool is required. Each jack

has integral colour code wiring labels.

Independent 3rd Party Certification (3P)

PRODUCT CHARACTERISTICS

Outlet Style: Unshielded with

un-keyed RJ-45 port

Cable Entry: Rear, top and bottom

Colour: Black translucent

Body Materials: Polycarbonate UL94 – V0

Jack Contacts: 50μin (1.27μm) gold over

nickel plating

Termination Block Material: PBT UL94-V0

IDC Contacts: Titanium copper,

tin plated

Ammendments

EN 50173-1, EN 60603-7

Part Number

AC6JAKU002

Description

10G Unshielded Tool-free Jack

Product Part Numbering

Page 23: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

22

BRAND-REX CATEGORY 7 AND 7A CABLING

Designed for use in Class F and FA systems

and backwards compatible to lower

classes.

Key Features

media cables that exceed the Category 7

and Category7A requirements of

of compliance (from 3P) are available

high bandwidth and high frequency

multi-media broadcast applications.

Suitable for cable sharing applications.

by individual screening of balanced

cable pairs.

systems and for providing a platform

for transmissions of multi-media and

broadcast technologies.

C AT E G O R Y 7 A N D 7 A S Y S T E M S

Page 24: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

23

7600MHz

Brand-Rex Copper Cables - U-MediaPlus

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

Ω

Gigabit Ethernet protocol for installation in

horizontal and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 23 AWG Plain Annealed

Copper Wire

Insulation: Cellular Polyolefin

Diameter: 1.36mm Nominal

Pair: 2 of the above cores

Tape Screen: Individual pair wrapped with

aluminium polyester tape,

applied metal side out

(Pair in Metal Foil)

Pair Colour: Blue-White, Orange-White,

Green-White, Brown-White

Final Assembly

Cable: 4 of the above screened pairs

Braid Screen: Tinned Annealed

Copper Wire

Sheath: LHSF

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: 20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

C AT E G O R Y 7 A N D 7 A S Y S T E M S

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ.km @ 100-500 V test voltage

Min 80 db

0.5%

100% in process test

>5 GΩ.km

90 db

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Transfer Impendance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

Cable Standards

The cable is compliant with:

ISO/IEC 61156-5 ed2:2009 and

EN 50288-4-1

Sheath

TACW Braid

23 AWG PACW

Cellular Polyolefin Insulation

Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 155 200 250 300 600

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)Spec

Typical

Return Loss (dB / 100m)Spec

Typical

Typical

Typical

ACR (dB / 100m)

PSACR (dB / 100m)

2.0

1.9

80.0

100.0

77.0

97.0

80.0

90.0

77.0

87.0

NA

27.0

98.1

95.1

2.0

1.9

80.0

100.0

77.0

97.0

80.0

90.0

77.0

87.0

NA

27.0

98.1

95.1

5.7

5.5

80.0

100.0

77.0

97.0

74.0

90.0

71.0

87.0

25.0

30.0

94.5

91.5

7.2

7.0

80.0

100.0

77.0

97.0

69.9

86.7

66.9

83.7

25.0

30.0

93.0

90.0

8.1

7.8

80.0

100.0

77.0

97.0

68.0

84.8

65.0

81.8

25.0

30.0

92.2

89.2

10.1

9.9

80.0

100.0

77.0

97.0

64.1

80.9

61.1

77.9

23.6

28.6

90.1

87.1

14.5

14.1

75.5

98.0

72.8

95.0

58.1

74.9

55.1

71.9

21.5

26.5

83.9

80.9

18.5

18.0

72.4

94.3

69.4

91.3

54.0

70.8

51.0

67.8

20.1

25.1

76.3

73.3

23.4

22.7

69.6

90.9

66.6

87.9

50.2

67.0

47.2

64.0

18.8

23.8

68.1

65.1

26.8

26.1

67.9

88.9

64.9

85.9

48.0

64.8

45.0

61.8

18.0

23.0

62.8

59.8

30.2

29.4

66.5

87.1

63.5

84.1

46.0

62.8

43.0

59.8

17.3

22.3

57.7

54.7

33.3

32.5

65.3

85.7

62.3

82.7

44.5

61.3

41.5

58.3

17.3

21.8

53.3

50.3

48.9

47.6

60.8

80.3

57.8

77.3

38.4

55.2

35.4

52.2

17.3

19.7

32.6

29.6

na

54.1

na

78.5

na

75.5

na

53.3

na

50.3

na

19.0

24.5

21.5

na

60.0

na

77.1

na

74.1

na

51.7

na

48.7

na

18.4

17.1

14.1

na

63.8

na

76.3

na

73.3

na

50.8

na

47.8

na

18.1

12.5

9.5

750 900 1000

Product Part Numbering

UM10-HF1-500VT

UM10-HF1-1000VT

UM10-HF1-D500VT

UM10-HF1-D1000VT

UM10-HF1-X-500BK

UM10-HF1-X-1000BK

UM10-HF3-500BU

UM10-HF3-1000BU

UM10-HF3-D500BU

UM10-HF3-D1000BU

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

IEC 60332-3-24

500

1000

500

1000

500

1000

500

1000

500

1000

LSHF

LSHF

PE

LSHF

LSHF

Violet

Violet

Black

Blue

Blue

7.2

14.7 x 7.3

8.4

7.4

14.9 x 7.4

0.11

0.24

0.32

0.12

0.25

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

44

91

57

48

96

Page 25: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

24

7600MHz

Brand-Rex Copper Cables – U-MediaPlus

PRODUCT DESCRIPTION

gigabit Ethernet protocol for installation in

horizontal and backbone areas

PRODUCT PERFORMANCE

Core

Core conductor: 22 AWG Plain Annealed

Copper Wire

Insulation: Cellular Polyolefin

Diameter: 1.5mm nominal

Pair: 2 of the above cores

Tape Screen: individual pairs wrapped

with aluminium polyester

tape applied metal side out

Final Assembly

Cable: 4 of the above shielded

pairs Tinned Annealed

Copper Wire

Sheath: LSHF

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x outer diameter

(installation) 4 x outer

diameter (operation)

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500mΩ.km @ 100-500 V test voltage

Min 80 db

0.5%

100% in process test

>5 gΩ.km

90 db

conductor loop resistance

conductor resistance unbalance

dielectric Strength

insulation resistance

capacitance unbalance to earth

Velocity of propagation

Skew

mean characteristic impendance

transfer impendance

coupling attenuation up to 1ghz

Electrical Characteristics @ 20°c Specification Typical Performance

Cable Standards

The cable is compliant with:

and ISO/IEC 61156-5

Frequency (MHz) 1 10 100 250 500 600 1000 1200

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)

PS ANEXT (dB / 100m)

PS AE LFEXT (dB / 100m)

Spec

Typical

Return Loss (dB / 100m)

Spec

Typical

TypicalACR (dB / 100m)

-

2.0

78

100

75

97

78

100

75

100

67

100

67

100

-

27

95

5.8

5.7

78

100

75

97

74

90

71

87

67

100

58

85

25

30

91

18.5

18.0

72

100

69

97

54

70

51

67

63

85

38

65

20

25

79

29.7

28.9

66

84

63

81

46

62

43

59

57

79

30

57

17

22

52

42.8

41.6

62

80

59

77

40

56

37

53

52

75

24

51

17

21

35

47.1

45.9

61

78

58

75

38

54

35

51

51

73

23

49

17

21

29

61.9

60.3

57

75

54

72

34

50

31

47

48

70

18

45

17

19

12

-

66.6

-

74

-

71

-

48

-

45

-

69

-

43

-

18

4

C AT E G O R Y 7 A N D 7 A S Y S T E M S

Product Part Numbering

UM12-HF1-500VT

UM12-HF1-1000VT

UM12-HF1-D500VT

UM12-HF1-D1000VT

UM12-HF3-500BU

UM12-HF3-1000BU

UM12-HF3-D500BU

UM12-HF3-D1000BU

500

1000

500

1000

500

1000

500

1000

LSHF

LSHF

LSHF

LSHF

Violet

Violet

Blue

Blue

7.55

15.2 x 7.55

7.75

7.75

65

131

59

121

0.15

0.31

0.20

0.41

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Spec

Typical

Spec

Typical

Sheath

TACW Braid

22 AWG PACW

Cellular Polyolefin Insulation

Page 26: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

25

BRAND-REX CAT6PLUS SYSTEM

(CATEGORY 6 - CLASS E)

Key Features

performance cabling system, it is

interoperable with standards compliant

products and fully backwards compatible

to lower performances classes. Third party

independent certificates of compliance

are available for cables, component and

channel performance from 3P Testing and

GHMT Laboratories GmbH

Cat6Plus makes it a reliable and safe choice

of cabling to support Gigabit Ethernet.

bit error rate given the extra margin

afforded by Cat6Plus

10GBASE-T in any channel configuration.

(Subject to testing to IEC TR 24750)

applications up to 550MHz

(PoE and PoEP) applications including:

- VoIP

- WLAN access points

- Security cameras etc

and unshielded options

C AT E G O R Y 6 S Y S T E M S

Page 27: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

26 26

The Cat6Plus System

Structured wiring systems comprising of Cat6Plus cables, patch leads and connectivity are designed to be compliant with the current

EN50173-1 (including IEEE802.3ab Gigabit Ethernet).

Cat6Plus is a premium grade cabling system that is characterised to 550MHz, its performance significantly exceeds the requirements

Brand-Rex Copper Cables - Cat6Plus Channel PerformanceUnshielded and Shielded systems

C AT E G O R Y 6 S Y S T E M S

Frequency (MHz)

Attenuation (dB)Typical

Spec

NEXT (dB)Typical

Spec

PSNEXT (dB)Typical

Spec

Return Loss (dB)Typical

Spec

ELFEXT (dB)Typical

Spec

PSELFEXT (dB)

Propagation Delay (ns)

Delay Skew (ns)

ACR (dB)

PSACR (dB)

Typical

Spec

Typical

Spec

Typical

Spec

Typical

Spec

Typical

Spec

1.9

2.1

80.7

65.0

78.6

62.0

28.0

19.0

78.3

63.3

75.3

60.3

520

580

<30

<50

78.8

62.9

76.7

59.9

3.5

4.0

71.0

63.0

68.8

60.5

25.0

19.0

66.2

51.2

63.2

48.2

505

562

<30

<50

67.6

59.0

65.3

56.5

5.5

6.3

64.6

56.6

62.3

54.0

23.0

19.0

58.3

43.3

55.3

40.3

500

555

<30

<50

59.1

50.2

56.8

47.7

7.0

8.0

61.2

53.2

58.9

50.6

22.0

18.0

54.2

39.2

51.2

36.2

500

553

<30

<50

54.3

45.2

51.9

42.6

7.8

9.0

59.6

51.6

57.2

49.0

21.5

17.5

52.2

37.2

49.2

34.2

500

552

<30

<50

51.8

42.6

49.4

39.9

9.8

11.4

56.4

48.4

54.0

45.7

20.5

16.5

48.4

33.4

45.4

30.4

500

550

<30

<50

46.6

37.0

44.1

34.3

14.2

16.5

51.4

43.4

48.8

40.6

19.0

14.0

42.3

27.3

39.3

24.3

500

549

<30

<50

37.2

26.9

34.6

24.1

18.4

21.3

47.9

39.9

45.3

37.1

18.0

12.0

38.3

23.3

35.3

20.3

500

548

<30

<50

29.6

18.6

26.9

15.8

20.8

24.1

46.3

38.3

43.6

35.4

17.5

11.0

36.3

21.3

33.3

18.3

500

547

<30

<50

25.5

14.2

22.9

11.3

23.4

27.2

44.7

36.7

42.0

33.8

17.0

10.1

34.5

19.5

31.5

16.5

500

547

<30

<50

21.3

9.51

8.6

6.6

25.0

29.2

43.8

35.8

41.1

32.9

16.8

9.6

33.4

18.4

30.4

15.4

500

547

<30

<50

18.7

6.6

16.0

3.7

27.0

31.5

42.8

34.8

40.1

31.9

16.5

9.0

32.2

17.2

29.2

14.2

500

547

<30

<50

15.8

3.3

13.1

0.3

30.6

35.9

41.1

33.1

38.3

30.2

16.0

8.0

30.3

15.3

27.3

12.3

500

546

<30

<50

10.5

-2.8

7.7

-5.8

37.2

35.6

32.8

15.3

22.4

19.4

500

<30

-1.6

-4.5

45.9

32.9

30.0

14.5

19.3

16.3

500

<30

-13.1

-15.9

48.6

32.2

29.3

14.3

18.4

15.4

500

<30

-16.5

-19.4

4 Connector Channel Performance

1 4 10 16 20 31.25 62.5 100 125 155 175 200 250 350 500 550

Channel

Central Computer Room

Patch Panel

Building

Riser

Outlet

Terminal

Page 28: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

27

6250MHz

Brand-Rex Copper Cables - Cat6Plus

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

Ethernet protocol for installation in horizontal

and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 23 AWG Plain Annealed

Copper Wire

Insulation: Polyolefin

Diameter: 1.00mm Nominal

Pair: 2 of the above cores

Pair Colour: Blue-White, Orange-White,

Green-White, Brown-White

Final Assembly

Cable: 4 of the above pairs cabled

together around a cross filler

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Sheath

Cross Filler

Polyolefin

23 AWG PACW

Cable Standards

The cable is compliant with:

and ANSI/TIA/EIA 568C

C AT E G O R Y 6 S Y S T E M S

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ.km @ 100-500 V test voltage

Min 40 dB

0.5%

100% in process test

>5 GΩ.km

56 dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 155 200 250 300 550

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)Spec

Typical

Return Loss (dB / 100m)Spec

Typical

Typical

Typical

ACR (dB / 100m)

PSACR (dB / 100m)

2.1

1.9

66.0

86.5

64.0

84.5

66.0

85.0

64.0

82.0

na

27.0

84.6

82.6

3.8

3.5

65.3

77.5

63.3

75.5

58.0

73.0

55.0

70.0

23.0

30.0

73.9

71.9

6.0

5.5

59.3

71.5

57.3

69.5

50.0

65.0

47.0

62.0

25.0

30.0

66.0

64.0

7.6

7.0

56.2

68.4

54.2

66.4

45.9

60.9

42.9

57.9

25.0

30.0

61.4

59.4

8.5

7.8

54.8

67.0

52.8

65.0

44.0

59.0

41.0

56.0

25.0

30.0

59.1

57.1

10.7

9.9

51.9

64.1

49.9

62.1

40.1

55.1

37.1

52.1

23.6

28.6

54.2

52.2

15.5

14.1

47.4

59.6

45.4

57.6

34.1

49.1

31.1

46.4

21.5

26.5

45.5

43.5

19.9

18.0

44.3

56.5

42.3

54.5

30.0

45.0

27.0

42.0

20.1

25.1

38.5

36.5

25.3

22.7

41.4

53.6

39.4

51.6

26.2

41.2

23.2

38.2

18.8

23.8

30.9

28.9

29.1

26.1

39.8

52.0

37.8

50.0

24.0

39.0

21.0

36.0

18.0

23.0

25.9

23.9

33.0

29.4

38.3

50.5

36.3

48.5

22.0

37.0

19.0

34.0

17.3

22.3

21.1

19.1

na

32.5

na

49.3

na

47.3

na

35.5

na

32.5

na

21.8

16.9

14.9

na

45.4

na

45.4

na

43.4

na

30.2

na

27.2

na

19.9

0.0

-2.0

C6U-HF1-Rlx-305VT

C6U-HF1-500VT

C6U-HF1-1000VT

C6U-HF1-D500VT

C6U-HF1-D1000VT

C6U-HF3-500BU

C6U-HF3-1000BU

C6U-HF3-D500BU

C6U-HF3-D1000BU

C6U-HF1-X-500BK

C6U-HF1-X-1000BK

305

500

1000

500

1000

500

1000

500

1000

500

1000

LSHF

LSHF

LSHF

LSHF

PE

Violet

Violet

Blue

Blue

Black

5.75

11.6 x 5.75

6.55

13.2 x 6.55

6.95

38

77

51

103

49

0.14

0.28

0.23

0.46

0.27

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Product Part Numbering

Page 29: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

28

6250MHz

Brand-Rex Copper Cables – Cat6Plus

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

ethernet protocol for installation in horizontal

and backbone areas, PoE, PoEP a and broadband

video transmissions at frequencies as high as

550MHz.

PRODUCT PERFORMANCE

Core

Core conductor: 23 AWG Plain Annealed

Copper Wire

Insulation: Polyolefin

Diameter: 1.2mm nominal

Pair: 2 of the above cores

Tape Screen: Wrapped with aluminium

polyester tape

Final Assembly

Cable: 4 of the above pairs cabled

together around a cross filler

Drainwire: 0.5mm Tinned Annealed

Copper Wire

Tape Screen: Wrapped with aluminium

polyester tape, applied

metal side in

Sheath: LSHF

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x outer diameter

(installation) 4 x outer

diameter (operation)

Max 2%

1.0kV d.c. or 0.7kV a.c. for 1min

>500 MΩ.km @ 100-500V test voltage

100 Ω ± 5Ω @ 100 MHz

Min 55dB

0.2%

100% in process test

>5000 MΩ.km

100 Ω ± 3Ω @ 100 MHz

80dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Transfer Impendance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

Cable Standards

The cable is compliant with:

ISO/IEC 61156-5 and EN 50288-5-1

Frequency (MHz) 4 10 16 20 31.25 62.5 100 155 200 250 500

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)Spec

Typical

Return Loss (dB / 100m)Spec

Typical

Typical

Typical

ACR (dB / 100m)

PSACR (dB / 100m)

2.1

1.9

66.0

80.0

64.0

80.0

66.0

82.0

64.0

79.0

na

27.0

78.1

78.1

3.8

3.5

65.3

71.0

63.3

71.0

58.0

70.0

55.0

67.0

23.0

30.0

67.4

67.4

6.0

5.5

59.3

65.0

57.3

65.0

50.0

62.0

47.0

59.0

25.0

30.0

59.5

59.5

7.6

7.0

56.2

61.9

54.2

61.9

45.9

57.9

42.9

54.9

25.0

30.0

54.9

54.9

8.5

7.8

54.8

60.5

52.8

60.5

44.0

56.0

41.0

53.0

25.0

30.0

52.6

52.6

10.7

9.9

51.9

57.6

49.9

57.6

40.1

52.1

37.1

49.1

23.6

28.6

47.7

47.7

15.5

14.1

47.4

53.1

45.4

53.1

34.1

46.1

31.1

43.1

21.5

26.5

39.0

39.0

19.9

18.0

44.3

50.0

42.3

50.0

30.0

42.0

27.0

39.0

20.1

25.1

32.0

32.0

25.3

22.7

41.4

47.1

39.4

47.1

26.2

38.2

23.2

35.2

18.8

23.8

24.4

24.4

29.1

26.1

39.8

45.5

37.8

45.5

24.0

36.0

21.0

33.0

18.0

23.0

19.4

19.4

33.0

29.4

38.3

44.0

36.3

44.0

22.0

34.0

19.0

31.0

17.3

22.3

14.6

14.6

550 600

-

43.0

-

39.5

-

39.5

-

28.0

-

25.0

-

20.2

-3.5

-3.5

-

45.4

-

38.9

-

38.9

-

27.2

-

24.2

-

19.9

-6.5

-6.5

C AT E G O R Y 6 S Y S T E M S

Product Part Numbering

305

500

1000

500

1000

LSHF

LSHF

Violet

Violet

7.1

14.3 x 7.1

50

101

0.19

0.37

IEC 60332-1-2

IEC 60332-1-2

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Sheath

Cross Filler

23 AWG PACW

Polyolefin Insulation

TACW Drainwire

Page 30: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

29

6250MHz

Brand-Rex Copper Cables - Cat6Plus

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

Ethernet protocol for installation in horizontal

and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 23 AWG Plain

Annealed Copper Wire

Insulation: Polyolefin

Diameter: 1.36mm Nominal

Pair: 2 of the above cores

Tape Screen: Individual pair wrapped with

aluminium polyester tape

applied metal side out

Pair Colour: Blue-White, Orange-White

Green-White, Brown-White

Final Assembly

Cable: 4 of the above pairs cabled

together around a cross filler

Drainwire: 0.5mm Tinned Annealed

Copper Wire

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MOhm @ 100-500 V test voltage

0.5%

100% in process test

>5 GOhm.km

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Transfer Impendance

Electrical Characteristics @ 20°c Specification Typical Performance

Cable Standards

The cable is compliant with:

and ANSI/TIA/EIA 568C

Sheath

Polyester Tape

Polyolefin Insulation

23 AWG PACW

TACW Drainwire

Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 155 200 250

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)Spec

Typical

Return Loss (dB / 100m)Spec

Typical

Typical

Typical

ACR (dB / 100m)

PSACR (dB / 100m)

2.1

1.9

66.0

100.0

64.0

97.0

66.0

90.0

64.0

87.0

20.0

30.0

98.1

95.1

3.8

3.5

65.3

100.0

63.3

97.0

58.0

89.0

55.0

86.0

23.0

30.0

96.5

93.5

6.0

5.5

59.3

100.0

57.3

97.0

50.0

85.0

47.0

82.0

25.0

30.0

94.5

91.5

7.6

7.0

56.2

100.0

54.2

97.0

45.9

81.0

42.9

78.0

25.0

30.0

93.0

90.0

8.5

7.8

54.8

100.0

52.8

97.0

44.0

76.0

41.0

73.0

25.0

30.0

92.2

89.2

10.7

9.9

51.9

100.0

49.9

97.0

40.1

72.0

37.1

69.0

23.6

27.0

90.1

87.1

15.5

14.1

47.4

100.0

45.4

97.0

34.1

67.0

31.1

64.0

21.5

25.0

85.9

82.9

19.9

18.0

44.3

100.0

42.3

97.0

30.0

60.0

27.0

57.0

20.1

24.0

82.0

79.0

25.3

22.7

41.4

100.0

39.4

97.0

26.2

52.0

23.2

49.0

18.8

22.0

77.3

74.3

29.1

26.1

39.8

100.0

37.8

97.0

24.0

50.0

21.0

47.0

18.0

21.0

73.9

70.9

33.0

29.4

38.3

95.0

36.3

92.0

22.0

49.0

19.0

46.0

17.3

20.0

65.9

62.6

300 600

na

32.5

na

90.0

na

87.0

na

40.0

na

37.0

na

19.0

57.5

54.5

na

47.6

na

90.0

na

87.0

na

35.0

na

32.0

na

17.0

42.4

39.4

C AT E G O R Y 6 S Y S T E M S

Product Part Numbering

500

1000

500

1000

LSHF

LSHF

Violet

Violet

7.15

14.4 x 7.15

50

100

0.12

0.25

IEC 60332-1-2

IEC 60332-1-2

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Page 31: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

30

6250MHz

Brand-Rex Copper Cables - Cat6Plus

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

Ethernet protocol for installation in horizontal

and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 23 AWG Plain

Annealed Copper Wire

Insulation: Cellular Polyolefin

Diameter: 1.36mm Nominal

Pair: 2 of the above cores

Tape Screen: Individual pair wrapped with

aluminium polyester tape

applied metal side out

Pair Colour: Blue-White, Orange-White

Green-White, Brown-White

Final Assembly

Cable: 4 of the above shielded pairs

Drainwire: Tinned Annealed

Copper Wire

Tape Screen: Wrapped with aluminium

polyester tape, applied metal

side in

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Sheath

Cellular Polyolefin Insulation

23 AWG PACW

TACW Drainwire

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ @ 100-500 V test voltage

Min 55 dB

0.5%

100% in process test

>500 MΩ.km

75 dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Transfer Impendance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

Cable Standards

The cable is compliant with:

and ANSI/TIA/EIA 568C

C AT E G O R Y 6 S Y S T E M S

Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 155 200 250 300 600

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)Spec

Typical

Return Loss (dB / 100m)Spec

Typical

Typical

Typical

ACR (dB / 100m)

PSACR (dB / 100m)

2.1

1.9

66.0

100.0

64.0

97.0

66.0

90.0

64.0

88.0

23.0

30.0

96.5

93.5

3.8

3.5

65.3

100.0

63.3

97.0

58.0

89.0

55.0

86.0

23.0

30.0

96.5

93.5

6.0

5.5

59.3

100.0

57.3

97.0

50.0

85.0

47.0

82.0

25.0

30.0

94.5

91.5

7.6

7.0

56.2

100.0

54.2

97.0

45.9

81.0

42.9

78.0

25.0

30.0

93.0

90.0

8.5

7.8

54.8

100.0

52.8

97.0

44.0

76.0

41.0

73.0

25.0

30.0

92.2

89.2

10.7

9.9

51.9

100.0

49.9

97.0

40.1

72.0

37.1

69.0

23.6

27.0

90.1

87.1

15.5

14.1

47.4

100.0

45.4

97.0

34.1

67.0

31.1

64.0

21.5

25.0

85.5

82.9

19.9

18.0

44.3

100.0

42.3

97.0

30.0

60.0

27.0

57.0

20.1

24.0

82.0

79.0

25.3

22.7

41.4

100.0

39.4

97.0

26.2

52.0

23.2

49.0

18.8

22.0

77.3

74.3

29.1

26.1

39.8

100.0

37.8

97.0

24.0

50.0

21.0

47.0

18.0

21.0

74.0

71.0

33.0

29.4

38.3

95.0

36.3

92.0

22.0

49.0

19.0

46.0

17.3

20.0

65.6

62.6

na

32.5

na

90.0

na

87.0

na

40.0

na

37.0

na

19.0

57.5

54.5

na

47.6

na

90.0

na

87.0

na

35.0

na

32.0

na

17.0

42.4

39.4

Product Part Numbering

500

1000

500

1000

500

1000

LSHF

LSHF

LSHF

Violet

Violet

Blue

7.2

14.5 x 7.2

7.6

51

102

60

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

0.13

0.26

0.15

Page 32: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

31

6250MHz

Brand-Rex Copper Cables - Cat6Plus

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

Ethernet protocol for installation in horizontal

and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 23 AWG Plain

Annealed Copper Wire

Insulation: Cellular Polyolefin

Diameter: 1.36mm Nominal

Pair: 2 of the above cores

Tape Screen: Individual pair wrapped with

aluminium polyester tape

applied metal side out

Pair Colour: Blue-White, Orange-White

Green-White, Brown-White

Final Assembly

Cable: 4 of the above pairs

Braid Screen: Tinned Annealed

Copper Wire

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Mini Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Sheath

TACW Braid

Cellular Polyolefin Insulation

23 AWG PACWCable Standards

The cable is compliant with:

and ANSI/TIA/EIA 568C

C AT E G O R Y 6 S Y S T E M S

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ.km @ 100-500 V test voltage

Min 55 dB

0.5%

100% in process test

>5 GΩ.km

90 dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impendance

Transfer Impendance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

1 4 10 16 20 31.25 62.5 100 155 200 250 300 600

2.1

1.9

66.0

100.0

64.0

97.0

66.0

90.0

64.0

87.0

23.0

30.0

96.5

93.5

3.8

3.5

65.3

100.0

63.3

97.0

58.0

90.0

55.0

87.0

23.0

30.0

96.5

93.5

6.0

5.5

59.3

100.0

57.3

97.0

50.0

90.0

47.0

87.0

25.0

30.0

94.5

91.5

7.6

7.0

56.2

100.0

54.2

97.0

45.9

86.7

42.9

83.7

25.0

30.0

93.0

90.0

8.5

7.8

54.8

100.0

52.8

97.0

44.0

84.8

41.0

81.8

25.0

30.0

92.2

89.2

10.7

9.9

51.9

100.0

49.9

97.0

40.1

80.9

37.1

77.9

23.6

28.6

90.1

87.1

15.5

14.1

47.4

98.0

45.4

95.0

34.1

74.9

31.1

71.9

21.5

26.5

83.9

80.9

19.9

18.0

44.3

94.3

42.3

91.3

30.0

70.8

27.0

67.8

20.1

25.1

76.3

73.3

25.3

22.7

41.4

90.9

39.4

87.9

26.2

67.0

23.2

64.0

18.8

23.8

68.1

65.1

29.1

26.1

39.8

88.9

37.8

85.9

24.0

64.8

21.0

61.8

18.0

23.0

62.8

59.8

33.0

29.4

38.3

87.1

36.3

84.1

22.0

62.8

19.0

59.8

17.3

22.3

57.7

54.7

na

32.5

na

85.7

na

82.7

na6

1.3

na

58.3

na

21.8

53.3

50.3

na

47.6

na

80.3

na

77.3

na

55.2

na

52.2

na

19.7

32.6

29.6

Frequency (MHz)

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)Spec

Typical

Return Loss (dB / 100m)Spec

Typical

Typical

Typical

ACR (dB / 100m)

PSACR (dB / 100m)

Product Part Numbering

500

1000

500

1000

500

1000

LSHF

LSHF

LSHF

Violet

Violet

Blue

7.2

14.5 x 7.4

7.6

44

91

48

0.11

0.24

0.12

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Page 33: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

32

6250MHz

SFTP

MMCPCCHB001

MMCPCCHB002

MMCPCCHB003

MMCPCCHB004

MMCPCCHB005

MMCPCCHB006

Part Number

PRODUCT DESCRIPTION

Brand-Rex Cat6Plus patch cords enable

you to get the optimum performance

from your cabling system. Our factory

made and tested patch cords offer you

guaranteed quality, and ensure that

your system avoids the performance

degradation which inferior alternatives will

give you at high data rates. All patch cords

are supplied with boots and ID tag.

Independent 3rd Party Certification (3P)

Packaging

easy tear bags

in bags of 10 for standard cords

Brand-Rex Copper Patch Cords - Cat6PlusCategory 6 Patch Cords

Part Number Format

C6C-PC-A-bbb-cde-F

Compliant with ISO/IEC 61935-2

UTP

C AT E G O R Y 6 S Y S T E M S

U 24AWG UTP

SFTP

S Solid

X Crossover

BB Blade style

H Standard

010 1 metre

020 2 metre

030 3 metre

050 5 metre

Additional lengths on request

1 Red

4 Blue

5 Green

6 Yellow

8 Grey

A - Cord Type bbb - Cord Length cde - Colour Scheme

(c) Cable

1 Red

4 Blue

5 Green

6 Yellow

8 Grey

(d) Boot 1

1 Red

4 Blue

5 Green

6 Yellow

8 Grey

(e) Boot 2

F - Speciality Tag

Additional colours on request

Product Part Numbering

Product Part Numbering

Non standard colour and length options are available to order on request.

Red Blue Green Yellow

C6CPCU010-111BB

C6CPCU020-111BB

C6CPCU030-111BB

C6CPCU050-111BB

C6CPCS010-188HB

C6CPCS020-188HB

C6CPCS030-188HB

C6CPCS050-188HB

C6CPCU010-444BB

C6CPCU020-444BB

C6CPCU030-444BB

C6CPCU050-444BB

C6CPCS010-488HB

C6CPCS020-488HB

C6CPCS030-488HB

C6CPCS050-488HB

C6CPCU010-555BB

C6CPCU020-555BB

C6CPCU030-555BB

C6CPCU050-555BB

C6CPCS010-588HB

C6CPCS020-588HB

C6CPCS030-588HB

C6CPCS050-588HB

C6CPCU010-666BB

C6CPCU020-666BB

C6CPCU030-666BB

C6CPCU050-666BB

C6CPCS010-688HB

C6CPCS020-688HB

C6CPCS030-688HB

C6CPCS050-688HB

C6CPCU010-888BB

C6CPCU020-888BB

C6CPCU030-888BB

C6CPCU050-888BB

C6CPCS010-888HB

C6CPCS020-888HB

C6CPCS030-888HB

C6CPCS050-888HB

Grey

SFTP Patch Cord Clip – Red

SFTP Patch Cord Clip – Black

SFTP Patch Cord Clip – White

SFTP Patch Cord Clip – Blue

SFTP Patch Cord Clip – Green

SFTP Patch Cord Clip – Yellow

100

100

100

100

100

100

Description Qty

S 26AWG

24 AWG UTP - 1.0m

24 AWG UTP - 2.0m

24 AWG UTP - 3.0m

24 AWG UTP - 5.0m

26 AWG SFTP - 1.0m

26 AWG SFTP - 2.0m

26 AWG SFTP - 3.0m

26 AWG SFTP - 5.0m

Page 34: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

33

483

132

44

.1

6250MHz

PRODUCT DESCRIPTION

The Cat6Plus 19" rack mounted patch panel offers

true Category 6 component performance using

a new patented contact pin array design.

All panels are backward compatible. The modular

jacks that are used in blocks of 8 are individually

shielded to give superior shielding.

In addition to this, each panel has been designed

built into the rear. All outlets are numerically

identified with an additional writable surface for

ease of port naming. Each panel is supplied with

cable ties, panel mounting accessories and short

form installation instructions.

PRODUCT CHARACTERISTICS

Panel Width: 19" (483mm)

Panel Height: 1U (44.1mm)

Panel Depth: 132mm

Outlet Style: Unkeyed RJ-45

Outlets: 24 ports

Colour: RAL 9005 Black

or RAL 7035 Grey

Punch Down Blocks: LSA style IDC

Conformance: Category 6

AMMENDMENTS

EN50173-1

Brand-Rex Copper Connectivity - Cat6Plus PanelsCategory 6 Panel with cable management

24 Port

Product Part Numbering

Shielded Panel LSA Style - Black

Shielded Panel LSA Style - Grey

Unshielded Panel LSA Style - Black

Unshielded Panel 110 Style - Black

C6CPNLF240K2M

C6CPNLF240K8M

C6CPNLU240K2M

C6CPNLU24012M

C AT E G O R Y 6 S Y S T E M S

Page 35: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

34

6250MHz

C AT E G O R Y 6 S Y S T E M S

Lighter & narrower than conventional

patch panels

Ideal for server cabinets where space is a factor

Ideal for small projects with space restrictions

Suitable for the small telecom enclosure

approach

and cabinets.

PRODUCT DESCRIPTION

Shielded and Unshielded patch panels offer a

port density which delivers 48 terminations in a

single U height with true Category 6 component

performance using a patented contact pin array

design. The robust and easy to install patch panel

employs a conventional termination method that

affords the installer the maximum punch down

accessibility for wire termination.

To assure the optimum link performance the

panel has been designed with integral rear cable

management which provides easy routing and

strain relief for the high performance cabling.

introduces shielded mounting clips to assure

optimum earthing of the cable screens.

PRODUCT CHARACTERISTICS

Panel Width: 19” (483mm)

Panel Height: ½ U (22mm)

Panel Depth: 105mm

Outlet Style: Unkeyed RJ-45

Outlets: 24 ports

Colour: RAL 9005 Black or

RAL 7035 Grey

Punch Down Blocks: LSA style IDC

Conformance: Category 6

AMMENDMENT EN 50173-1

Brand-Rex Copper Connectivity – Cat6Plus PanelsCategory 6 Half U 24 Port Patch Panel

Part Number

C6CPNLU240K2H

C6CPNLU240K8H

C6CPNLF240K2H

C6CPNLF240K8H

Description

Cat6Plus ½ U 24 Port Unshielded Panel

Cat6Plus ½ U 24 Port Unshielded Panel

Cat6Plus ½ U 24 Port Shielded Panel

Cat6Plus ½ U 24 Port Shielded Panel

Colour

Black

Grey

Black

Grey

Unshielded

Shielded

Product Part Numbering

Page 36: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

35

6250MHz

5e100MHz

Part Number

C6CJAKS000

Description

Category 6 Shielded Tool-Free Jack

Qty per Pack

12

PRODUCT DESCRIPTION

The Cat6Plus Shielded Tool-free Snap-in-Jack is

easy and quick to install, its compact construction

and multiple cable-entry options make it the

most flexible product of its type available. It is

smaller and shorter than traditional products,

allowing it to fit more comfortably into confined

spaces. The jack also features an adjustable

management element allowing for a rear, top or

side-entry cable termination.

Designed for use in all structured cabling

environments including the general office and

data centres, the jack can be installed in patch

panels, wall outlets and floor box modules to

provide a robust and versatile solution.

The Cat6Plus system is a Category 6 and Class E

solution set that is fully backwards compatible

to Cat5e (Class D) products. The jack is fully

compatible with all our UK and Continental style

faceplates and patch panel products

PRODUCT CHARACTERISTICS

Outlet Style: Shielded keystone type with

unkeyed RJ-45 ports

Cable Entry: Rear

Hole Plate Thickness: Up to 1.6mm

Body Material: Zinc

Jack Contacts: 50μin (1.27μm) gold over

nickel plating

Punch Down Blocks: Tool-free with push down

cable manager for wire AWG

22-27 solid

Wire Terminations: Tool-Free with cap

IDC Contacts: Tin plated titanium copper

Conformance: Category 6 compliant – can

support 10GBASE-T in a

channel configuration.

Conforms to all of the

physical reliability

requirements defined in

the IEC 60603-7 series of

TIA 568 C set (including

‘over-stress’ testing up to

2,500 insertion cycles with a

standard plug).

Also available in Augmented Category 6

Brand-Rex Copper Connectivity – Cat6Plus Tool-free Jack Category 6 Shielded Tool-free Snap-in-Jack

C AT E G O R Y 6 S Y S T E M S

Product Part Numbering

Page 37: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

36

6250MHz

31

21.6

46.6

23.6

23

.62

1.9

Brand-Rex Copper Connectivity - Cat6Plus JacksCategory 6 Snap-In-Jacks

PRODUCT DESCRIPTION

The Brand-Rex Cat6Plus Snap-In-Jack offers

true Category 6 component performance using

a new patented contact array design. The jack

is backward compatible and also fully compatible

with all our UK and continental style faceplates

and products. Jacks are supplied with a short

form installation instruction.

PRODUCT CHARACTERISTICS

Outlet Style: Unshielded and

shielded Keystone

type with RJ-45 ports

Cable Entry: Top and Rear

Hole Plate Thickness: Jack will clip into sheet

material with a thickness

of 1.6mm max.

Body Material: High impact

PBT UL94 - VO

Jack Contacts: 50μin (1.27μm)

over nickel plating

Punch Down Blocks: LSA (Shielded)

LSA or 110 (Unshielded)

style IDC

IDC Contacts: Phosphor Bronze

Conformance: Category 6

amm1

EN50173-1 : 2007

Approval: (3P) Independent

3rd Party CertificationUnshielded Shielded

Product Part Numbering

LSA Style - Black

LSA Style - White

110 Style - Black

110 Style - White

C6CJAKU0K2

C6CJAKU0K3

C6CJAKU012

C6CJAKU013

C6CJAKF0K2

-

-

-

C AT E G O R Y 6 S Y S T E M S

Other colours available on request.

Page 38: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

37

6250MHz

5e100MHz

PRODUCT DESCRIPTION

The Tool-free Jack offers true Cat6 performance

and is fully compatible with Brand-Rex UK and

continental UNI style faceplates and products.

The jacks come supplied in boxes of 12;

termination instructions are on the rear of the

box. No termination tool is required. Each jack

has integral colour code wiring labels.

PRODUCT CHARACTERISTICS

Outlet Style: Unshielded with

un-keyed RJ-45 port

Cable Entry: Rear, top and bottom

Colour: Black translucent

Body Materials: UL94 – V0

Jack Contacts: 50μin (1.27μm)

gold over nickel plating

Termination Block Material: UL94-V0

IDC Contacts: Titanium copper, tin plated

Conformance: Category 6

AMMENDMENT

EN 50173-1 : 2002

Part Number

C6CJAKU002Category 6 Unshielded Tool-free Jack

C AT E G O R Y 6 S Y S T E M S

Brand-Rex Copper Connectivity - Cat6Plus JacksCategory 6 Unshielded Tool-free Jack

Product Part Numbering

Page 39: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

38

6250MHz

Brand-Rex Copper Connectivity - Cat6Plus OutletsCategory 6 Triple Shuttered Outlet

PRODUCT DESCRIPTION

The Brand-Rex Cat6Plus Unshielded Triple

Outlet offers a high density outlet solution

with true Category 6 component performance.

The outlet is backward compatible with our UK

and continental UNI style faceplates providing

a 3 or 6 RJ-45 solution for high density

outlet installations.

Each outlet is fitted with a removable label

protector with individual rear cable anchors

and colour wiring detail. Every outlet is supplied

in an easy tear pack with a shortform installation

instruction, paper label and cable ties.

PRODUCT CHARACTERISTICS

Outlet Style: Unkeyed RJ-45

style compatible

Backbox: Minimum 32mm depth

Colour: RAL 9010 White

Weight: 46g

Body Material: ABS

Jack Contacts: 50μin (1.27μm)

gold over nickel plating

Plating: 50μm gold over

100μm nickel

Punch Down Blocks: 110 Style IDC

Conformance: Category 6

EN50173-1:2007

Unshielded

Product Part Numbering

Triple Outlet - White C6CTWOU013

C AT E G O R Y 6 S Y S T E M S

Page 40: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

39

6250MHz

69.90

33

69

35

40

.5

PRODUCT DESCRIPTION

The Brand-Rex combined shielded outlet and

RJ-45 socket has the same proven Category 6

performance as our Cat6Plus panels. Primarily

designed for mounting into duct or trunking

using a 45mm diameter hole, the outlet can

be either flush or wall mounted by using the

80 x 80mm continental styled faceplate and

33mm back box.

PRODUCT CHARACTERISTICS

Outlet Style: Shielded Keystone

type with unkeyed

RJ-45 ports

Cable Entry: Horizontal and Vertical

Colour: RAL 1013 Ivory

RAL 9010 White

Body Material: High impact

PPO UL94 - VO

Zinc Alloy Diecast

closed housing

Jack Contacts: 50μin (1.27μm)

gold over nickel plating

Plating: 50 μm gold over

100 μm of nickel

Punch Down

Blocks: LSA style IDC

IDC Contacts: Phosphor Bronze

EN50173-1

Brand-Rex Copper Connectivity - Cat6Plus OutletsCategory 6 European Style Outlet

C AT E G O R Y 6 S Y S T E M S

Product Part Numbering

White Ivory

18870NB

18879NB

07058GF

18870NA

18879NA

07058GE

1 Way Shielded Outlet

2 Way Shielded Outlet

80mm x 80mm Faceplate and Back Box

Page 41: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

40

6250MHz

C AT E G O R Y 6 S Y S T E M S

TOWER UNITS PRODUCT DESCRIPTION

The tower mount frame provides a modular,

high density, cross-connect and cable

management system. The base tower is

supplied as a 288 pair unit but the capacity

can be increased using additional extension

frames. Tower units are supplied with wiring

bases and connector blocks for 288 pair.

PRODUCT CHARACTERISTICS

Material: Mild steel,

Black powder coated

Dimensions:

288 pair mounting frame

546.1 x 215.9 x 235.0mm

288 pair extension mounting frame

416.0 x 215.9 x 88.9mm

Vertical cable organiser

546.1 x 215.9 x 235.0mm

Vertical cable organiser extension

426.5 x 215.9 x 228.6mm

PATCHCORD PRODUCT DESCRIPTION

Cross-connect patchcords are available in 110

to 110 style or 110 to RJ45 style. The standard

Category 6 110 connector is supplied in a 4 pair

version only.

PRODUCT CHARACTERISTICS

Conformance: Category 6

Cord type: Grey 24AWG UTP 110 – 110

Dimensions: 50.2 x 30.9 x 9.0mm

Temperature Range: 0 to 50 °C (installation)

-20 to 75 °C (operational)

Brand-Rex Copper Connectivity - Cat6Plus Cross-Connect Category 6 Cross-Connect Tower Units and Patchcord

Tower Unit Product Part Numbering

110 Tower, 288 pair mounting frame

110 Tower, 288 pair extension mounting frame

C6C110TWR288P

C6C110TWR288PE

110 – 110 110 – RJ45

Cross Connect Patch Cord - 1.0m C6C110110PC010 C6C110RJ4PC010

Cross Connect Patch Cord - 1.5m C6C110110PC015 C6C110RJ4PC015

Cross Connect Patch Cord - 2.0m C6C110110PC020 C6C110RJ4PC020

Cross Connect Patch Cord - 3.0m C6C110110PC030 C6C110RJ4PC030

Cross Connect Patch Cord - 4.0m C6C110110PC040 C6C110RJ4PC040

Cross Connect Patch Cord - 5.0m C6C110110PC050 C6C110RJ4PC050

Patchcord Product Part Numbering

Page 42: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

41

Brand-Rex Copper Connectivity - Cat6Plus Cross-Connect Category 6 Cross-Connect Insertion Tool and Wiring Bases and

Connector Blocks

PRODUCT DESCRIPTION

Insertion Tool

To ensure correct termination of Brand-Rex’s

Category 6 Cross Connect solution it is advised

to use a specially designed Insertion tool.

The insertion tool is used to simultaneously

terminate the 4 pairs onto Category 6 Cross

Connect wiring bases and underneath the

Category 6 connector block. A Replacement

Head is also available when the tool

becomes worn.

Wiring Base

The Category 6 110 wiring base can be supplied as

a 48, 96 or 288 pair version, with or without legs. It

can also be supplied rack mounted as

a 96, 192 or 288 pair version. Designation

labels are included with the bases.

48 Pair Wiring Base Kits

A typical kit for a 48 pair wiring base

includes a basic wiring base and 12 off

4 pair connector blocks.

96 Pair Wiring Base Kits

A typical kit for a rack mounted 96 pair wiring base

includes 2 off 48 pair wiring base and

24 off 4 pair connector blocks.

Connector Block

The 4 pair connector is specifically designed to

exceed Category 6 performance, has a robust

design and is colour coded for easy identification.

The connector is supplied in bags of 10.

PRODUCT CHARACTERISTICS

Conformance: Category 6

Connector Block

Material: Flame retardent

thermoplastic rated

UL94V-0, off-white

Wiring Base

Material: Flame retardent

thermoplastic rated

UL94V-0, off-white

Contact Material: Copper Alloy, tin plated

C AT E G O R Y 6 S Y S T E M S

Product Part Numbering

Category 6 110 4 pair Insertion Tool C6C1104PIT

Category 6 110 4 pair Replacement Head C6C1104PITRH

Category 6 110 wiring base 48 pair with legs C6C110WB48PL

Category 6 110 wiring base 48 pair without legs C6C110WB48P

Category 6 110 wiring base 48 pair with legs, Kit C6C110WB48PLK

Category 6 110 wiring base 48 pair without legs, Kit C6C110WB48PK

Category 6 110 wiring base 96 pair with legs C6C110WB96PL

Category 6 110 wiring base 96 pair without legs C6C110WB96P

Category 6 110 wiring base 96 pair with legs, Kit C6C110WB96PLK

Category 6 110 wiring base 96 pair without legs, Kit C6C110WB96PK

Category 6 110 wiring base 288 pair with legs C6C110WB288PL

Category 6 110 wiring base 288 pair without legs C6C110WB288P

Category 6 110 wiring base 288 pair with legs, Kit C6C110WB288PLK

Category 6 110 wiring base 288 pair without legs, Kit C6C110WB288PK

Category 6 110 wiring base 96 pair rack mounted, Kit C6C110WB96PRK

Category 6 110 wiring base 192 pair rack mounted, Kit C6C110WB192PRK

Category 6 110 wiring base 288 pair rack mounted, Kit C6C110WB288PRK

Category 6 110 Connector Block C6C110CB4P

Vertical Cable Organiser for 110 Tower CMV110TWR

Vertical Cable Organiser Extension for 110 Tower CMV110TWRE

Page 43: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

42

BRAND-REX GIGAPLUS SYSTEM

(CATEGORY 5E - CLASS D)

Key Features

open system

EIA 568C

by 3P and GHMT

cost-effective and flexible Cat5e

cabling system solution for running

today’s LAN protocols and high speed

applications such as 1000Base-T

of system margins that exceed

the standards

and unshielded options

backwards compatible

hostile environments, contact

Brand-Rex for recommendations

and advice

and PoEP) compatible and supports

- VoIP

- Wireless LAN access points

- Security cameras

C AT E G O R Y 5 E S Y S T E M S

Page 44: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

43

The GigaPlus System

Structured wiring systems comprising of GigaPlus cables, patch cords and connectivity are designed to be compliant with the current

(including Gigabit Ethernet).

GigaPlus is a premium grade cabling system that is characterised to 250MHz. Its performance significantly exceeds the requirements

Brand-Rex Copper Cables - GigaPlus Channel PerformanceShielded and Unshielded Systems

C AT E G O R Y 5 E S Y S T E M S

4 Connector Channel Performance

Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 125 155 175 200

Attenuation (dB)Typical

Spec

NEXT (dB)Typical

Spec

PSNEXT (dB)Typical

Spec

Return Loss (dB)Typical

Spec

ELFEXT (dB)Typical

Spec

PSELFEXT (dB)

Propagation Delay (ns)

Delay Skew (ns)

Typical

Spec

Typical

Spec

Typical

Spec

Typical

TypicalACR (dB / 100m)

PSACR (dB / 100m)

Alien NEXT (dB)

2.0

2.3

73.6

60.0

70.6

57.0

22.0

17.0

70.0

57.4

67.0

54.4

520

<555

<20

<50

71.6

68.6

103.6

4.0

4.6

62.3

53.5

59.3

50.5

22.0

17.0

57.9

45.3

54.9

54.4

510

<555

<20

<50

58.3

55.3

92.3

6.4

7.3

54.9

47.0

51.9

44.0

22.0

17.0

50.0

45.3

47.0

37.4

505

<555

<20

<50

48.5

45.5

84.9

8.1

9.3

51.0

43.6

48.0

40.6

22.0

17.0

45.9

33.3

42.9

30.3

503

<555

<20

<50

42.9

39.9

81.0

9.1

10.4

49.2

42.0

46.2

39.0

22.0

17.0

44.0

31.4

41.0

28.4

502

<555

<20

<50

40.0

37.0

79.2

11.5

13.2

45.5

38.7

42.5

35.7

20.1

15.1

40.1

27.5

37.1

24.5

501

<555

<20

<50

34.0

31.0

75.5

16.6

19.1

39.8

33.6

36.8

30.6

17.1

12.1

34.1

21.5

31.1

18.5

500

<555

<20

<50

23.2

20.2

69.8

21.3

24.7

35.9

30.1

32.9

27.1

15.0

10.0

30.0

17.4

27.0

14.4

500

<555

<20

<50

14.6

11.6

65.9

24.0

na

34.0

na

31.0

na

14.0

na

28.0

na

25.0

na

500

na

<20

na

10.0

7.0

64.0

27.0

na

32.2

na

29.2

na

13.1

na

26.2

na

23.2

na

500

na

<20

na

5.2

2.2

62.2

28.8

na

31.2

na

28.2

na

12.6

na

25.1

na

22.1

na

500

na

<20

na

2.4

-0.6

61.2

31.0

na

30.1

na

27.1

na

12.0

na

24.0

na

21.0

na

500

na

<20

na

-0.9

-3.9

60.1

250

32.5

na

30.1

na

29.7

na

11.8

na

26.4

na

24.6

na

505

na

<20

na

-0.8

-1.5

59.2Typical

Channel

Central Computer Room

Patch Panel

Building

Riser

Outlet

Terminal

Page 45: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

44

5e100MHz

C AT E G O R Y 5 E S Y S T E M S

Brand-Rex Copper Cables - GigaPlus

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

Ethernet protocol for installation in horizontal

and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 24 AWG Plain Annealed

Copper Wire

Insulation: Polyolefin

Diameter: 0.94mm Nominal

Pair: 2 of the above cores

Pair Colour: Blue-White, Orange-White,

Green-White, Brown-White

Final Assembly

Cable: 4 of the above pairs

Sheath: LSHF or for external cables

PE compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Sheath

24 AWG PACW

Polyolefin InsulationCable Standards

The cable is compliant with:

and ANSI/TIA/EIA 568C

Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 155 200

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)Spec

Typical

Return Loss (dB / 100m)Spec

Typical

4.0

3.6

56.3

64.3

53.3

62.3

51.8

66.8

48.8

64.8

23.1

28.0

60.7

58.7

6.3

5.8

50.3

58.3

47.3

56.3

43.8

58.8

40.8

56.8

25.0

30.0

52.5

50.5

8.0

7.4

47.3

55.2

44.2

53.2

39.7

54.7

36.7

52.7

25.0

30.0

47.8

45.8

9.0

8.3

45.8

53.8

42.8

51.8

37.8

52.8

34.8

50.8

25.0

30.0

45.5

43.5

11.4

10.5

42.9

50.9

39.9

48.9

33.9

48.9

30.9

46.9

23.6

38.6

40.4

38.4

16.5

15.3

38.4

46.4

35.4

44.4

27.9

42.9

24.9

40.9

21.5

26.5

31.1

29.1

21.3

19.8

35.3

43.3

32.3

41.3

23.8

38.8

20.8

36.8

20.1

25.1

23.5

21.5

na

25.4

na

40.4

na

38.4

na

35.0

na

33.0

na

23.8

15

13

na

29.4

na

38.8

na

36.8

na

32.8

na

30.8

na

23.0

9.4

7.4

ACR (dB / 100m)

PSACR (dB / 100m)

Typical

Typical

2.1

1.8

65.3

73.3

62.3

71.3

63.8

78.8

60.8

76.8

na

25.0

71.5

69.5

250

na

33.4

na

37.3

na

35.3

na

31.5

na

29.5

na

22.8

3.9

1.9

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ.km @ 100-500 V test voltage

Min 40 dB

0.5%

100% in process test

>5 GΩ.km

50dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impedance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

Product Part Numbering

GPU-HF1-Rlx-305VT

GPU-HF1-500VT

GPU-HF1-1000VT

GPU-HF1-D500VT

GPU-HF1-D1000VT

GPU-HF3-500BU

GPU-HF3-1000BU

GPU-HF3-D500BU

GPU-HF3-D1000BU

GPU-HF1-X-500BK

GPU-HF1-X-1000BK

305

500

1000

500

1000

500

1000

500

1000

500

1000

LSHF

LSHF

LSHF

LSHF

PE

Violet

Violet

Blue

Blue

Black

4.85

10.0 x 4.95

5.65

11.4 x 5.65

6.1

30

63

41

82

40

0.09

0.19

0.17

0.34

0.21

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Page 46: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

45

5e100MHz

Brand-Rex Copper Cables - GigaPlus

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

protection for installations in horizontal

and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 24 AWG Plain

Annealed Copper Wire

Insulation: Polyolefin

Diameter: 1.07mm Nominal

Pair: 2 of the above cores

Pair Colour: Blue-White, Orange-White

Green-White, Brown-White

Final Assembly

Cable: 4 of the above pairs

Binder: Wrapped with polyester

tape, 100% coverage

Drainwire: 0.5mm Tinned

Annealed Copper Wire

Tape Screen: Wrapped with aluminium

polyester tape

applied metal side in

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Sheath

24 AWG PACW

Polyolefin Insulation

TACW Drainwire

Cable Standards

The cable is compliant with:

and ANSI/TIA/EIA 568C

C AT E G O R Y 5 E S Y S T E M S

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ.km @ 100-500 V test voltage

Min 55 dB

0.5%

100% in process test

>5 GΩ.km

75 dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impedance

Transfer Impedance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 155 200

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)Spec

Typical

Return Loss (dB / 100m)

ACR (dB / 100m)

PSACR (dB / 100m)

Spec

Typical

Typical

Typical

2.1

2.0

65.3

73.3

62.3

70.3

63.8

78.8

60.8

76.8

na

25.0

71.3

68.3

4.0

3.8

56.3

64.3

53.3

61.3

51.8

66.8

48.8

64.8

23.0

28.0

60.5

57.5

6.3

6.0

50.3

58.3

47.3

55.3

43.8

58.8

40.8

56.8

25.0

30.0

52.3

49.3

8.0

7.6

47.2

55.2

44.2

52.2

39.7

54.7

36.7

52.7

25.0

30.0

47.6

44.6

9.0

8.6

45.8

53.8

42.8

50.8

37.8

52.8

34.8

50.8

25.0

30.0

45.2

42.2

11.4

10.8

42.9

50.9

39.9

47.9

33.9

48.9

30.9

46.9

23.6

28.6

40.0

37.0

16.5

15.8

38.4

46.4

35.4

43.4

27.9

42.9

24.9

40.9

21.5

26.5

30.6

27.6

21.4

20.4

35.3

43.3

32.3

40.3

23.8

38.8

20.8

36.8

20.1

25.1

22.9

19.9

na

26.1

na

40.4

na

37.4

na

35.0

na

33.0

na

23.8

14.3

11.3

na

30.3

na

38.3

na

35.8

na

32.8

na

30.8

na

23.0

8.5

5.5

250

na

34.5

na

37.3

na

34.3

na

30.8

na

28.8

na

22.3

2.9

-0.1

Product Part Numbering

GPF-HF1-Rlx-305VT

GPF-HF1-500VT

GPF-HF1-1000VT

GPF-HF1-D500VT

GPF-HF1-D1000VT

GPF-HF3-500BU

GPF-HF3-1000BU

GPF-HF3-D500BU

GPF-HF3-D1000BU

GPF-HF1-X-500BK

GPF-HF1-X-1000BK

305

500

1000

500

1000

500

1000

500

1000

500

1000

LSHF

LSHF

LSHF

LSHF

PE

Violet

Violet

Blue

Blue

Black

5.9

12.1 x 6.0

6.5

13.1 x 6.5

7.4

37

78

46

92

49

0.12

0.25

0.19

0.38

0.26

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Page 47: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

46

5e100MHz

Brand-Rex Copper Cables - GigaPlus

Independent 3rd Party Certification (3P)

PRODUCT DESCRIPTION

Ethernet protocol combined with exceptional

and backbone areas.

PRODUCT PERFORMANCE

Core

Conductor: 24 AWG Plain

Annealed Copper Wire

Insulation: Polyolefin

Diameter: 1.10mm Nominal

Pair: 2 of the above cores

Pair Colour: Blue-White, Orange-White

Green-White, Brown-White

Final Assembly

Cable: 4 of the above pairs

Binder: Wrapped with polyester tape

100% coverage

Tape Screen: Wrapped with aluminium

polyester tape

applied metal side out

Braid Screen: Tinned Annealed

Copper Wire

Sheath: LSHF compound

Mechanical and Environmental

Temp - Installation: 0°c to +50°c

Temp - Operation: -20°c to +75°c

Max Tensile Load: 10kg per simplex cable

(installation)

Min Bend Radius: 8 x Outer Diameter

(installation)

4 x Outer Diameter

(operation)

Sheath

TACW Braid

24 AWG PACW

Polyolefin Insulation

Max 2%

1.0kV dc or 0.7kV ac for 1 min

>500MΩ.km @ 100-500 V test voltage

Min 55 dB

0.5%

100% in process test

>5 GΩ.km

80 dB

Conductor Loop Resistance

Conductor Resistance Unbalance

Dielectric Strength

Insulation Resistance

Capacitance Unbalance to Earth

Velocity of Propagation

Skew

Mean Characteristic Impedance

Transfer Impedance

Coupling Attenuation up to 1Ghz

Electrical Characteristics @ 20°c Specification Typical Performance

Cable Standards

The cable is compliant with:

and ANSI/TIA/EIA 568C

C AT E G O R Y 5 E S Y S T E M S

Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 155 200

Insertion Loss (dB / 100m)Spec

Typical

NEXT (dB)Spec

Typical

PSNEXT (dB)Spec

Typical

ELFEXT (dB / 100m)Spec

Typical

PSELFEXT (dB / 100m)Spec

Typical

Return Loss (dB / 100m)Spec

Typical

Typical

Typical

ACR (dB / 100m)

PSACR (dB / 100m)

2.1

2.0

65.3

73.3

62.3

70.3

63.8

78.8

60.8

76.8

na

25.0

71.3

68.3

4.0

3.8

56.3

64.3

53.3

61.3

51.8

66.8

48.8

64.8

23.0

28.0

60.5

57.5

6.3

6.0

50.3

58.3

47.3

55.3

43.8

58.8

40.8

56.8

25.0

30.0

52.3

49.3

8.0

7.6

47.2

55.2

44.2

52.2

39.7

54.7

36.7

52.7

25.0

30.0

47.6

44.6

9.0

8.6

45.8

53.8

42.8

50.8

37.8

52.8

34.8

50.8

25.0

30.0

45.2

42.2

11.4

10.8

42.9

50.9

39.9

47.9

33.9

48.9

30.9

46.9

23.6

28.6

40.0

37.0

16.5

15.8

38.4

46.4

35.4

43.4

27.9

42.9

24.9

40.9

21.5

26.5

30.6

27.6

21.4

20.4

35.3

43.3

32.3

40.3

23.8

38.8

20.8

36.8

20.1

25.1

22.9

19.9

na

26.1

na

40.4

na

37.4

na

35.0

na

33.0

na

23.8

14.3

11.3

na

30.3

na

38.3

na

35.8

na

32.8

na

30.8

na

23.0

8.5

5.5

250

na

34.5

na

37.3

na

34.3

na

30.8

na

28.8

na

22.3

2.9

-0.1

Product Part Numbering

GPS-HF1-500VT

GPS-HF1-1000VT

GPS-HF1-D500VT

GPS-HF1-D1000VT

GPS-HF3-500BU

GPS-HF3-1000BU

GPS-HF3-D500BU

GPS-HF3-D1000BU

500

1000

500

1000

500

1000

500

1000

LSHF

LSHF

LSHF

LSHF

Violet

Violet

Blue

Blue

6.3

6.3

6.9

13.9 x 6.9

48

96

58

116

0.13

0.26

0.21

0.42

IEC 60332-1-2

IEC 60332-1-2

IEC 60332-3-24

IEC 60332-3-24

Length (m) Cable type Colour

Nominal

Cable Diameter

(mm)

Nominal

Weight

(Kg/Km)

Calorific

Value

kWh/m

Fire

Safety

RatingPart Number

Page 48: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

47

5e100MHz

Brand-Rex Copper Patch Cords - GigaPlus Category 5e Patch Cords

PRODUCT DESCRIPTION

Brand-Rex GigaPlus patch cords enable you to

get the optimum performance from your cabling

system. Our factory made and tested patch cords

offer you guaranteed quality, and ensure that

your system avoids the performance degradation

that inferior alternatives will give you at high data

rates. All patch cords are supplied with boots

and ID tag.

Independent 3rd Party Certification (3P)

Part Number Format

GPC-PC-A-bbb-cde-F

Compliant with ISO/IEC 61935-2

C AT E G O R Y 5 E S Y S T E M S

Red Blue Green Yellow

GPCPCU010-111HB

GPCPCU020-111HB

GPCPCU030-111HB

GPCPCU050-111HB

GPCPCF010-111H

GPCPCF020-111H

GPCPCF030-111H

GPCPCF050-111H

GPCPCU010-444HB

GPCPCU020-444HB

GPCPCU030-444HB

GPCPCU050-444HB

GPCPCF010-444H

GPCPCF020-444H

GPCPCF030-444H

GPCPCF050-444H

GPCPCU010-555HB

GPCPCU020-555HB

GPCPCU030-555HB

GPCPCU050-555HB

GPCPCF010-555H

GPCPCF020-555H

GPCPCF030-555H

GPCPCF050-555H

GPCPCU010-666HB

GPCPCU020-666HB

GPCPCU030-666HB

GPCPCU050-666HB

GPCPCF010-666H

GPCPCF020-666H

GPCPCF030-666H

GPCPCF050-666H

GPCPCU010-888HB

GPCPCU020-888HB

GPCPCU030-888HB

GPCPCU050-888HB

GPCPCF010-888H

GPCPCF020-888H

GPCPCF030-888H

GPCPCF050-888H

Grey

Product Part Numbering

Non standard colour and length options are available to order on request.

U

F

S Solid

X Crossover

HB Blade style

H Standard

010 1 metre

020 2 metre

030 3 metre

050 5 metre

Additional lengths on request

1 Red

4 Blue

5 Green

6 Yellow

8 Grey

A - Cord Type bbb - Cord Length cde - Colour Scheme

(c) Cable

1 Red

4 Blue

5 Green

6 Yellow

8 Grey

(d) Boot 1

1 Red

4 Blue

5 Green

6 Yellow

8 Grey

(e) Boot 2

F - Speciality Tag

Additional colours on request

Page 49: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

48

483

5e100MHz

Brand-Rex Copper Connectivity - GigaPlus PanelsCategory 5e Panel - Unshielded

PRODUCT DESCRIPTION

The GigaPlus 19" rack mounted patch

panel offers true Category 5e component

performance using patented state of the art

printed circuit technology. All outlets are

numerically identified with an additional

writable surface for ease of port naming.

Each panel is supplied with cable ties,

panel mounting accessories and short form

installation instructions.

PRODUCT CHARACTERISTICS

Panel Width: 19” (483mm)

Panel Height: 24 port 1U (44.1mm)

48 port 2U (88.5mm)

Panel Depth: 33.50mm

Outlet Style: Unkeyed RJ-45

Colour: RAL 9005 Black

Punch Down Blocks: Universal style IDC

Amm1

EN50173-1 : 2007

C AT E G O R Y 5 E S Y S T E M S

Product Part Numbering

Universal IDC - Black

24 Port

GPCPNLU24002 GPCPNLU48002

48 Port

Page 50: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

49

48344

.1

483

132

5e100MHz

C AT E G O R Y 5 E S Y S T E M S

Brand-Rex Copper Connectivity - GigaPlus PanelsCategory 5e Panel - with Cable Management

PRODUCT DESCRIPTION

The GigaPlus 19" rack mounted patch panel

offers true Category 5 component performance

using patented state of the art printed

circuit technology.

Available in 24 port versions, these panels have

into the rear mounted grounding bar. All outlets

are numerically identified with an additional

writable surface for ease of port naming. Each

panel is supplied with cable ties, panel mounting

accessories and short form

installation instructions.

PRODUCT CHARACTERISTICS

Panel Width: 19” (483mm)

Panel Height: 1U (44.1mm)

Panel Depth: 132.0mm

Outlet Style: Unkeyed RJ-45

Outlets: 24 ports

Colour: RAL 9005 Black

or RAL 7035 Grey

Punch Down Blocks: LSA or 110 style IDC

Amm1

EN50173-1 : 2007

Product Part Numbering

24 Port

Unshielded Panel 110 Style - Black

Shielded Panel LSA Style - Black

Shielded Panel 110 Style - Black

GPCPNLU24012M

GPCPNLF240K2M

GPCPNLF24012M

Page 51: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

50

5e100MHz

Brand-Rex Copper Connectivity - GigaPlus JacksCategory 5e Snap-In Lead Frame Jacks - Shielded and Unshielded

PRODUCT DESCRIPTION

GigaPlus Shielded and Unshielded

Snap-In-Jacks offer true Category 5e component

performance. The jack is backward compatible

and also fully compatible with all our UK and

Continental style faceplates and products.

Each jack is supplied with a short form

installation instruction and stuffer cap.

PRODUCT CHARACTERISTICS

Keystone type with

unkeyed RJ-45 ports

Cable Entry: Top and Rear

Hole Plate Thickness: 1.60mm max

Body Material: Impact modified PPO

UL94 - V0 rated

Jack Contacts: 50μin (1.27μm)

over nickel plating

Punch Down Blocks: 110 style IDC

IDC Contacts: Phosphor Bronze

& Amm1

EN50173-1

Unshielded Shielded

Product Part Numbering

110 style white

C AT E G O R Y 5 E S Y S T E M S

GPCJAKU013LF GPCJAKF013LF

Page 52: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

51

5e100MHz

Brand-Rex Copper Connectivity - GigaPlus JacksCategory 5e Snap-In-Jacks - Shielded and Unshielded

PRODUCT DESCRIPTION

GigaPlus Shielded and Unshielded

Snap-In-Jacks offer true Category 5e component

performance. The jacks are backward compatible

and also fully compatible with all our UK and

Continental style faceplates and products.

Each jack is supplied with a short form

installation instruction and cable tie.

PRODUCT CHARACTERISTICS

Keystone type with

unkeyed RJ-45 ports

Cable Entry: Top and Rear

Hole Plate Thickness: 1.60mm max

Body Material: Impact modified PBT

UL94 - V0 rated

Jack Contacts: 50μin (1.27μm)

gold over nickel plating

Punch Down Blocks: 110 or LSA style IDC

IDC Contacts: Phosphor Bronze

EN50173-1

C AT E G O R Y 5 E S Y S T E M S

Unshielded Shielded

LSA Style - Black

LSA Style - White

110 Style - Black

110 Style - White

-

GPCJAKU0K3

GPCJAKU012

GPCJAKU013

GPCJAKF0K2

-

GPCJAKF012

-

Other colours available on request.

Product Part Numbering

Page 53: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

52

5e100MHz

PRODUCT DESCRIPTION

The Tool-free Jack offers true Cat5e performance

and is fully compatible with Brand-Rex UK and

continental UNI style faceplates and products.

The jacks come supplied in boxes of 12;

termination instructions are on the rear of the

box. No termination tool is required. Each jack

has integral colour code wiring labels.

PRODUCT CHARACTERISTICS

Outlet Style: Unshielded with

un-keyed RJ-45 port

Cable Entry: Rear, top and bottom

Colour: Black translucent

Body Materials: UL94 – V0

Jack Contacts: 50μin (1.27μm)

gold over nickel plating

Termination Block Material: UL94-V0

IDC Contacts: Titanium copper, tin plated

Conformance: IS11801 : 2002 & Amm1

EN50173-I : 2007

TIA568C

C AT E G O R Y 5 E S Y S T E M S

Product Part Number

GPCJAKU002

Description

Category 5e Unshielded Tool-free Jack

Brand-Rex Copper Connectivity - GigaPlus JacksCategory 5e Unshielded Tool-free Jack

Product Part Numbering

Page 54: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

53

5e100MHz

25

50

25

7.4 25.2

50

18.6

38.6

25 18.6

C AT E G O R Y 5 E S Y S T E M S

PRODUCT DESCRIPTION

GigaPlus Slimline Shuttered Modules offer

true Category 5e component performance

and are fully compatible with Brand-Rex UK and

continental UNI style faceplates and products,

and are suitable for applications where internal

back box space is limited. Each jack is supplied

with a shortform installation instruction and a

cable tie to attach the cable to the cable anchor.

Modules are supplied with a colour code

wiring label.

PRODUCT CHARACTERISTICS

Keystone type with

unkeyed RJ-45 ports

Cable Entry: Rear and Top

Colour: Black or White

Body Material: High impact

ABS UL94 - VO

Jack Contacts: 50μin (1.27μm)

gold over nickel plating

Punch Down Blocks: Universal IDC

IDC Contacts: Phosphor Bronze

EN50173-1

Brand-Rex Copper Connectivity - GigaPlus ModulesCategory 5e Slimline Shuttered Modules - Shielded and Unshielded

Unshielded Shielded

Product Part Numbering

50mm x 25mm Slimline Shuttered Module - White

50mm x 25mm Slimline Shuttered Module - Black

38mm x 25mm Slimline Shuttered Module - White

38mm x 25mm Slimline Shuttered Module - Black

50mm x 25mm Angled Slimline Shuttered Module - White

50mm x 25mm Angled Slimline Shuttered Module - Black

GPCSL062UB03

GPCSL062UB02

GPCSL06CUB03

GPCSL06CUB02

GPCSLA62UB03

GPCSLA62UB02

GPCSL062SB03

GPCSL062SB02

GPCSL06CSB03

GPCSL06CSB02

GPCSLA62SB03

GPCSLA62SB02

Page 55: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

54

5e100MHz

Brand-Rex Copper Connectivity - GigaPlus OutletsCategory 5e Triple Shuttered Outlet PRODUCT DESCRIPTION

The Brand-Rex GigaPlus Unshielded Triple

Outlet offers a high density outlet solution

with true Category 5e component performance.

The outlet is backward compatible with our UK

and continental UNI style faceplates providing

a 3 or 6 RJ-45 solution for high density outlet

installations.

Each outlet is fitted with a removable label

protector with individual rear cable anchors and

colour wiring detail. Every outlet is supplied in

an easy tear pack with a shortform installation

instruction, paper label and cable ties.

PRODUCT CHARACTERISTICS

Outlet Style: Unkeyed RJ-45

style compatible

Backbox: Minimum 32mm depth

Colour: RAL 9010 White

Body Material: ABS

Jack Contacts: 50μin (1.27μm)

gold over nickel plating

Style IDC

Conformance: Category 5e

568C

EN50173-1

Unshielded

Product Part Numbering

Triple Shuttered Module - White GPCTWOU003

C AT E G O R Y 5 E S Y S T E M S

Page 56: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

55

69.90

33

69

5e100MHz

35

40

.5

PRODUCT DESCRIPTION

The Brand-Rex combined shielded outlet and

RJ-45 socket has the same true Category 5e

performance as our GigaPlus panels.

Primarily designed for mounting into duct or

trunking using a 45mm diameter hole, the outlet

can be either flush or wall mounted by using

the 80 x 80mm continental styled faceplate

and 33mm back box.

PRODUCT CHARACTERISTICS

Outlet Style: Shielded Keystone

type with unkeyed

RJ-45 ports

Cable Entry: Horizontal or Vertical

Colour: RAL 1013 Ivory

or RAL 9010 White

Body Material: High impact

PPO UL94 - VO

Jack Contacts: 50μin (1.27μm)

gold over nickel plating

Punch Down Blocks: LSA style IDC

IDC Contacts: Phosphor Bronze

EN50173-1

Brand-Rex Copper Connectivity - GigaPlus OutletsCategory 5e European Style Outlet

C AT E G O R Y 5 E S Y S T E M S

Product Part Numbering

2 Way Shielded Outlet

80 x 80 Faceplate and Back Box

White Ivory

GPCG245SU002

MMCWDOSMA002

GPCG245SU001

MMCWDOSMA001

Page 57: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

56

5e100MHz

TOWER UNITS PRODUCT DESCRIPTION

The tower mount frame provides a modular,

high density, cross connect and cable

management system. The base tower is supplied

as a 300 pair unit but the capacity can be

increased using additional extension frames.

Tower units are supplied with wiring bases

and connector blocks for 300 pair.

PRODUCT CHARACTERISTICS

Material: Mild steel,

Black powder coated

Dimensions:

300 pair mounting frame

546.1 x 215.9 x 235.0mm

300 pair extension mounting frame

416.0 x 215.9 x 88.9mm

Vertical cable organiser

546.1 x 215.9 x 235.0mm

Vertical cable organiser extension

426.5 x 215.9 x 228.6mm

PATCHCORDS PRODUCT DESCRIPTION

Cross Connect patchcords are available in 110

to 110 style or 110 to RJ45 style. The standard

Category 5e 110 connector can be supplied

as a 4 pair or 1 pair version.

PRODUCT CHARACTERISTICS

Conformance: Category 5e

Cord type: Grey 24AWG UTP

Dimensions: 50.2 x 30.9 x 9.0mm (4 pair)

57.5 x 7.4 x 9.0mm (1 pair)

Temperature Range: 0 to 50 °C (installation)

-20 to 75 °C (operational)

Brand-Rex Copper Connectivity - GigaPlus Cross Connect Category 5e Cross Connect Tower Units and Patchcord

C AT E G O R Y 5 E S Y S T E M S

Tower Unit Product Part Numbering

Cat5e 110 Tower, 300 pair mounting frame

Cat5e 110 Tower, 300 pair extension mounting frame

GPC110TWR300P

GPC110TWR300PE

Patchcord Product Part Numbering

110 – 110 1 Pair 110 – 110 4 Pair 110 – RJ45

Cross Connect Patch Cord - 1.0m GPC110110PC010-1 GPC110110PC010-4 GPC110RJ4PC010

Cross Connect Patch Cord - 1.5m GPC110110PC015-1 GPC110110PC015-4 GPC110RJ4PC015

Cross Connect Patch Cord - 2.0m GPC110110PC020 -1 GPC110110PC020-4 GPC110RJ4PC020

Cross Connect Patch Cord - 3.0m GPC110110PC030-1 GPC110110PC030-4 GPC110RJ4PC030

Cross Connect Patch Cord - 4.0m GPC110110PC040-1 GPC110110PC040-4 GPC110RJ4PC040

Cross Connect Patch Cord - 5.0m GPC110110PC050 -1 GPC110110PC050-4 GPC110RJ4PC050

Page 58: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

57

5e100MHz

PRODUCT DESCRIPTION

Wiring Base

The Category 5e 110-wiring base can be supplied

as a 50, 100 or 300 pair version, with or without

legs. It can also be supplied rack mounted as a

100, 200 or 300 pair version. Designation labels

are included with the bases.

50 Pair Wiring Base Kits

A typical kit for a 50 pair wiring base includes

a basic wiring base and 12 off 4 pair connector

blocks. A typical kit for a rack mounted 100 pair

wiring base includes 2 off 50 pair wiring base,

25 off 4 pair connector blocks and 5 off 5 pair

connector blocks.

Connector Block

The connector can be supplied as a 4 or 5 pair

version and is specifically designed to exceed

Category 5e performance. It has a robust design

and is colour coded for easy identification.

The connector is supplied in bags of 10.

PRODUCT CHARACTERISTICS

Conformance: Category 5e

Connector Block

Material: Flame retardent

thermoplastic rated

UL94V-0, off-white

Wiring Base

Material: Flame retardent

thermoplastic rated

UL94V-0, off-white

Contact Material: Copper Alloy, tin plated

Brand-Rex Copper Connectivity - GigaPlus Cross Connect Category 5e Cross Connect Wiring Bases and Connector

C AT E G O R Y 5 E S Y S T E M S

Product Part Numbering

Category 5e 110 wiring base 50 pair with legs GPC110WB50PL

Category 5e 110 wiring base 50 pair without legs GPC110WB50P

Category 5e 110 wiring base 50 pair with legs, Kit GPC110WB50PLK

Category 5e 110 wiring base 50 pair without legs, Kit GPC110WB50PK

Category 5e 110 wiring base 100 pair with legs GPC110WB100PL

Category 5e 110 wiring base 100 pair without legs GPC110WB100P

Category 5e 110 wiring base 100 pair with legs, Kit GPC110WB100PLK

Category 5e 110 wiring base 100 pair without legs, Kit GPC110WB100PK

Category 5e 110 wiring base 300 pair with legs GPC110WB300PL

Category 5e 110 wiring base 300 pair without legs GPC110WB300P

Category 5e 110 wiring base 300 pair with legs, Kit GPC110WB300PLK

Category 5e 110 wiring base 300 pair without legs, Kit GPC110WB300PK

Category 5e 110 wiring base 100 pair rack mounted, Kit GPC110WB100PRK

Category 5e 110 wiring base 200 pair rack mounted, Kit GPC110WB200PRK

Category 5e 110 wiring base 300 pair rack mounted, Kit GPC110WB300PRK

Category 5e 110 Connector Block – 4 Pair GPC110CB4P

Category 5e 110 Connector Block – 5 Pair GPC110CB5P

Vertical Cable Organiser for 110 Tower CMV110TWR

Vertical Cable Organiser Extension for 110 Tower CMV110TWRE

Page 59: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

58

BRAND-REX VOICE SYSTEM

(CATEGORY 3 - CLASS C)

The Brand-Rex Voice System is a

comprehensive system of high quality Voice

products forming part of the Brand-Rex

range and is therefore backed by a 25 year

system warranty for total peace of mind

panels that give maximum configurable

connections at both front and rear

performance voice links

(30 pair, 50 pair & 100 pair) plus

10 pair disconnection strips

total installed voice solutions

C AT E G O R Y 3 S Y S T E M S

Page 60: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

59

PRODUCT DESCRIPTION

Brand-Rex VOICE cables consist of 0.51mm

Polyolefin insulated conductors formed into

one or more units of twisted pairs. The units

are identified with coloured binders and are

assembled to form the cable core. The core

may be protected with one or more layers of

dielectric material and is covered by a protective

LSHF sheath.

PRODUCT CHARACTERISTICS

Core:

Conductor: Annealed copper,

0.51mm Diameter

Insulation: Polyolefin

Cabling Element: Twisted Pair

Colour Code: See Table 1 opposite

Final Assembly:

Core Stranding: 25 pair units

Unit Binders (see Table 2)

Binder: Wrapped with polyester

tape, 100% coverage

Sheath: LSHF compound

ELECTRICAL CHARACTERISTICS (@ 20°C)

NEXT (Max dB Power Sum in 25 pair units):

1 MHz 41 dB

4 MHz 32 dB

8 MHz 27 dB

10 MHz 26 dB

16 MHz 23 dB

Conformance: Category 3

Brand-Rex Copper Cables - VOICE

Sheath

Polyolefin Insulation

PET Tape

Annealed Copper Core

C AT E G O R Y 3 S Y S T E M S

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

White

White

White

White

White

Red

Red

Red

Red

Red

Black

Black

Black

Black

Black

Yellow

Yellow

Yellow

Yellow

Yellow

Violet

Violet

Violet

Violet

Violet

Blue

Orange

Green

Brown

Grey

Blue

Orange

Green

Brown

Grey

Blue

Orange

Green

Brown

Grey

Blue

Orange

Green

Brown

Grey

Blue

Orange

Green

Brown

Grey

Pair Number Colour - Conductor 1 Colour - Conductor 2

Table 1: Pair Colour Code

1

2

3

4

5

6

7

8

Blue-White

Orange-White

Green-White

Brown-White

Grey-White

Blue-Red

Orange-Red

Green-Red

1-25

26-50

51-75

76-100

101-125

126-150

151-175

176-200

Unit Number Binding Colour Pair Number (25 pair units)

Table 2: Unit Binder Colour Code

C3U25PRHF1

LSHF

9.50mm

Grey RAL 7035

IEC 60332-1

C3U50PRHF1

LSHF

13.0mm

Grey RAL 7035

IEC 60332-1

C3U100PRHF1

LSHF

18.0mm

Grey RAL 7035

IEC 60332-1

Part Number

Outer Sheath

Cable Weight

Outer Diameter (nom)

Sheath Colour

Fire Safety Rating

Part Number 25 Pair 50 Pair 100 Pair

Product Part Numbering

Page 61: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

60

483

142

44

.1

PRODUCT DESCRIPTION

The 19" rack mounted patch panel is available

in 25 and 50 port versions, both have a slimline

1U footprint suitable for compact installations

maximising rack space. These panels are supplied

with cable ties, earth lead, cable manager,

mounting bolts and short form instructions.

The rear of the panel offers a choice of between

60 and 150 voice pairs to suit a variety of PBX

(Private Branch eXchange) systems and direct

line connections.

This offers maximum flexibility for connection

to both future and existing PBX installations.

PRODUCT CHARACTERISTICS

Panel Width: 19” (483mm)

Panel Height 1U (44.45mm)

Panel Depth: 142.0mm

Outlet Style: Unkeyed RJ45

Outlets: 4 pin or 6 pin

Colour: RAL 9005 Black

or RAL 7035 Grey

Punch Down Blocks: LSA style IDC

Conformance: Category 3

C5CPNLU254PKM

C5CPNLU254PKM

CPCPNLU256PKM

C5CPNLU504PKM

C5CPNLU504PKM

CPCPNLU506PKM

4 Pin - Black

4 Pin - Grey

6 Pin - Black

25 Port 50 Port

Product Part Numbering

Brand-Rex Copper Connectivity - VOICEUnshielded Panels

C AT E G O R Y 3 S Y S T E M S

Page 62: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

61

Brand-Rex Copper Systems - VOICE Connectivity

PRODUCT DESCRIPTION

Brand-Rex VOICE includes a range of surface

mounted telecom boxes for multipair cable

termination, surface mounted outlets, 50 x 25mm

UK styled faceplate modules and line adaptor

fly leads.

Termination Boxes

The range of termination boxes is available

in a number of sizes to accommodate up to

10 x 10 pair disconnect termination modules.

Each box has been designed for easy access with

internal pair management and knockout cable

entry to provide a simple cost effective solution

for termination of incoming voice lines.

These units can be fitted before and after a PBX

(Private Branch eXchange) telephone system

providing for the removal or replacement of the

PBX unit with minimal disruption to incoming

and outgoing connections.

Telecom Outlet (LJU)

Available in PSTN, PBX or secondary units,

this product has a UK style telephone socket

and LSA style IDC cable termination.

Supplied as a standard UK style 68 x 68mm

faceplate, this outlet comes with a removable

21mm deep backbox, faceplate mounting

screws and installation instructions.

25 x 50mm Telecom Faceplate Module

As with our standard telecom outlet, this product

is also available in PSTN, PBX or secondary units,

with the same UK style telephone socket and LSA

style IDC cable termination. This unit has been

designed to mount in the Brand-Rex modular

range of faceplates.

Telecom Fly Lead Adaptor

PSTN, PBX or secondary units are available with

150 mm leads to convert an RJ-45 data outlet

into a standard UK style telephone outlet.

RANGE CHARACTERISTICS

Telephone Outlet: UK style 601 (6 pin)

with a right hand

latch position

Punchdown: LSA style IDC

C AT E G O R Y 3 S Y S T E M S

MMCWDBU03001

MMCWDBU05001

MMCWDBU10001

MMCDISU10PK001

MMCLBL10PU001

MMCLJUWMPSTN001

MMCLJUWMPABX001

MMCLJUWMSEC001

LJUPSTN001

LJUPBX001

LJUSEC001

LAUPSTNMSP001

LAUPBXM001

LAUSEC001

Wall Mount Dist Box - 3 Block (150 x 104 x 55)

Wall Mount Dist Box - 5 Block (129 x 160 x 90)

Wall Mount Dist Box - 10 Block (318 x 209 x 122)

Disconnection Block - 10 Pair

10 Pair Disconnect Block Label Holder

PSTN Master Single Outlet LJU Surface Mount

PBX Master Single Outlet LJU Surface Mount

Secondary Single Outlet LJU Surface Mount

PSTN 25 x 50mm LJU

PBX 25 x 50mm LJU

Secondary 25 x 50mm LJU

PSTN Fly Lead Adaptor

PBX Fly Lead Adaptor

Secondary Fly Lead Adaptor

White

Product Part Numbering

Not all parts are shown

Page 63: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

62

BRAND-REX COPPER

SYSTEMS ACCESSORIES

cabling system accessories to complement

any Brand-Rex structured cabling system

C O P P E R A C C E S S O R I E S

Page 64: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

63

CatAC6

Cat5e

Cat6

482.6

44.3

127.5

PRODUCT DESCRIPTION

The 48 Port 1U Snap-in-Jack Patch Panel is

ideally suited for data centre applications and

installations where rack space is at a premium.

The panel offers exceptional high density with

the ability to accommodate up to 48 jacks within

a 1U space on a 19” rack. Each panel is screened

with port identification strip and also panel

identification space to allow for easy port and

panel identification. The product has a detachable

front facia, allowing jacks to be removed from

the front of the cabinet, and is supplied with an

earthing point and a detachable cable manager.

Jacks are sold separately.

PRODUCT CHARACTERISTICS

Applications Equipment Racks & Cabinets

Installation: Suitable for approved

Brand-Rex Snap-in-Jacks

(see compatible System

Products below)

MECHANICAL SPECIFICATIONS

Dimensions: 483mm x 44.3mm (1U) x

127.5mm* (wxhxd)

*(With Manager Assembled)

Material Data: Panel and cable manager

manufactured from high

quality 1.5mm powder

coated steel, RAL9055 Black

with plastic fascia UL 94 V0

rated ABS

C O P P E R A C C E S S O R I E S

Brand-Rex Copper Connectivity - 48 Port 1U Patch Panel

Part Number

AC6JAKS000

C6CJAKS000

Description

10G Shielded Tool Free Jack

Category 6 Shielded Tool Free Jack

Quantity per Pack

12

12

Compatible System Products

Product Part Number

MMCPNLX48SIJ1U2

Description

48 Port 1U Snap in Jack Patch Panel

Product Part Numbering

Page 65: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

64

CatAC6

Cat5e

Cat6

483

10

PRODUCT DESCRIPTION

The Brand-Rex 19" Modular Panel is a rack

mounted Snap-In-Jack panel that has been

designed with a double skin to provide flush

mounted jacks. The rear of the panel has been

plated for grounding to the chassis on shielded

systems. All outlets are numerically identified

with an additional writable surface for ease

of port naming.

PRODUCT CHARACTERISTICS

Applications: Equipment Racks & Cabinets

Installation: Suitable for both

shielded and unshielded

applications when used in

conjunction with Brand-Rex

approved Snap-In-Jacks.

It is recommended that

a minimum of one cable

manager is used per 1U of

modular panel

MECHANICAL SPECIFICATIONS

Dimensions: 24 port 1U 483mm x

44.3mm x 135mm*

(wxhxd) 48 port 3U

483mm x 33.2mm x 135mm

Colour: RAL 9005 Black or

RAL 7035 Grey

C O P P E R A C C E S S O R I E S

Brand-Rex Copper Connectivity - Snap-In-Jack Modular Panels

MMCPNLX24SIJ2

MMCPNLX24SIJ8

MMCPNLX48SIJ2

MMCPNLX48SIJ8

Note: Panels supplied empty, Snap-In-Jacks must be purchased separately.

Modular Snap In Jack Panel - Black

Modular Snap In Jack Panel - Grey

Modular Panel Cable Manager - Black

Modular Panel Cable Manager - Grey

24 Port 48 Port 3U

Product Part Numbering

MMCACCCMSIJ2

MMCACCCMSIJ8

Page 66: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

65

6250MHz

AC6500MHz

5e100MHz

PRODUCT DESCRIPTION

The Brand-Rex Angled Snap-in-Jack Patch

Panel is a 1U 24 Port Panel that facilitates

cord routing directly into the rack vertical side

management thus rendering horizontal cable

managers redundant. The resultant increased

rack density not only saves valuable space but

also offers a panel that eases bending stresses

on the cord while maximising performance.

The design accommodates a separate rear

cable manager to provide a strain relief feature

for the simple routing of horizontal cabling

and also allows for colour coded labelling.

PRODUCT CHARACTERISTICS

Applications: Equipment racks

Cabinets

Installation: Suitable for approved

Brand–Rex Snap-in-jacks

(See compatible System

Products below)

MECHANICAL SPECIFICATIONS

[*With Manager assembled]

Material Data: Panel and cable manager

manufactured from

high quality 1.5mm

powder coated steel

RAL 9005 Black

Brand-Rex Copper Connectivity - Snap-In-Jack Angled Panel

Part Number

AC6JAKS000

AC6JAKU002

C6CJAKU002

C6CJAKS000

GPCJAKU002

GPCJAKU013LF

Description

Augmented Category 6 Shielded Jack

Augmented Category 6 Unshielded Jack (Tool-free)

Category 6 Unshielded Jack (Tool-free)

Category 6 Shielded Jack

Category 5 Unshielded Jack (Tool-free)

Category 5 Unshielded Jack

Colour

-

Black

Black

-

Black

White

Quantity per Pack

12

12

12

12

12

50

Compatible System Products

Product Part Number

MMCPNLX24SIJ2MAN

Description

C O P P E R A C C E S S O R I E S

Product Part Numbering

Page 67: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

66

CatAC6

Cat5e

Cat6

PRODUCT DESCRIPTION

The 19” inline Snap-in-Jack Patch Panel

accommodates 24 ports within a 1U

configuration and is compatible with all

standard 19” racks and cabinets. All outlets

are numerically identified with an additional

writable surface allowing for ease of port

naming. In addition to this, each panel has

strain relief feature built into the rear.

Each panel is supplied with cable ties,

panel mounting accessories and short

form installation instructions.

PRODUCT CHARACTERISTICS

Applications: Equipment Racks & Cabinets

Installation: Suitable for approved Brand-Rex

Snap-in-jacks

(See compatible System

Products below)

MECHANICAL SPECIFICATIONS

Dimensions: 24 port 1U 483mm x 44.5mm

x 124mm (WxHxD)

Colour: RAL9005 Black or RAL 7035 Grey

Brand-Rex Copper Connectivity - 24 Port Inline Snap-in-Jack Panels

Part Number

AC6JAKS000

AC6JAKU002

C6CJAKU002

C6CJAKS000

GPCJAKU002

GPCJAKU013LF

Description

Augmented Category 6 Shielded Jack (Tool-free)

Augmented Category 6 Unshielded Jack (Tool-free)

Category 6 Unshielded Jack (Tool-free)

Category 6 Shielded Jack (Tool-free)

Category 5 Unshielded Jack (Tool-free)

Category 5 Unshielded Jack (Lead Frame)

Colour

-

Black

Black

-

Black

White

Quantity per Pack

12

12

12

12

12

50

Compatible System Products

Product Part Number

MMCPNLX24SIJ2MIL

MMCPNLX24SIJ8MIL

Description

24 Port Inline Snap-in-Jack Panel

24 Port Inline Snap-in-Jack Panel

Colour

Black

Grey

C O P P E R A C C E S S O R I E S

Product Part Numbering

Page 68: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

67

CatAC6

Cat5e

Cat6

Coloured Insert Snap-in-Jack Panel – Black

Coloured Insert Snap-in-Jack Panel – Grey

Insert with Dust Cover - Red

Insert with Dust Cover - Black

Insert with Dust Cover - White

Insert with Dust Cover - Blue

Insert with Dust Cover - Green

Insert with Dust Cover - Yellow

Snap-in-Jack Blank

Snap-in-Jack Blank

Retraction Tool

MMCPNLX24SIJ2DCI

MMCPNLX24SIJ8DCI

MMCACCINSDC1

MMCACCINSDC2

MMCACCINSDC3

MMCACCINSDC4

MMCACCINSDC5

MMCACCINSDC6

MMCJAKBLK2

MMCJAKBLK3

MMCIRT001

Black

Grey

Red

Black

White

Blue

Green

Yellow

Black

White

Red

1

1

80

80

80

80

80

80

20

20

1

Part NumberDescription ColourQty

per pack

10GPlus Shielded Keystone Snap-in-Jack (Tool-free)

10GPlus Unshielded Jack (Tool-free)

Cat6Plus Unshielded Jack (Tool-free)

Cat6Plus Shielded Keystone Jack (Tool-Free)

GigaPlus Unshielded Jack (Tool-free)

GigaPlus Unshielded Jack (Lead Frame)

AC6JAKS000

AC6JAKU002

C6CJAKU002

C6CJAKS000

GPCJAKU002

GPCJAKU013LF

-

Black

Black

-

Black

White

12

12

12

12

12

50

Part NumberDescription Colour Qtyper pack

PRODUCT DESCRIPTION

The Brand-Rex 19” Snap-in-Jack Patch Panel

that accommodates 24 ports within a 1U

configuration and provides coloured inserts

The product is designed and supplied with

a detachable rear cable manager and comes

complete with black inserts with integrated

dust cover already loaded into the panel

as standard. Optional coloured inserts are

available for purchase separately in a variety

identification.

PRODUCT CHARACTERISTICS

Packaging: Panel and cable manager

packaged together in cardboard

box, panel populated with black

inserts qty 24, all other coloured

insert requirements packaged

separately in bags containing 8

of each colour, minimum order

quantity 10 bags.

Installation: Suitable for approved Brand-Rex

Snap-in-Jacks (see compatible

System Products below)

MECHANICAL SPECIFICATIONS

Dimensions: 483mm x 44.3mm (1U) x

127.5mm* (WxHxD)

*[With Manager Assembled]

Material Data: Panel and cable manager

manufactured from high quality

1.5mm powder coated steel,

RAL 9055 Black with plastic

fascia UL 94 V0 rated ABS

Brand-Rex Copper Connectivity - 24 Port Coloured Insert Snap-in-Jack Panels

C O P P E R A C C E S S O R I E S

Compatible System Products

Product Part Numbering

Page 69: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

68

483

483

44

.1

CatAC6

Cat5e

Cat6

Cat7

Brand-Rex Copper Connectivity - Blank PanelsPRODUCT DESCRIPTION

1U and 2U blank panels are used to complete

any installation in a cabinet. Designed to

complement the Brand-Rex range of patch panels,

they provide a more aesthetically pleasing finish

and offer improved user safety.

MECHANICAL SPECIFICATION

1U Rack Mounted

Panel Width: 19" (483mm)

Panel Height: 1U (44.1mm)

Panel Depth: 12.50mm

Colour: RAL 9005 Black

or RAL 7035 Grey

Material: 1.5mm Mild Steel

2U Rack Mounted

Panel Width: 19" (483mm)

Panel Height: 2U (88.5mm)

Panel Depth: 12.50mm

Colour: RAL 9005 Black

or RAL 7035 Grey

Material: 1.5mm Mild Steel

C O P P E R A C C E S S O R I E S

MMCACCCM004

MMCACCCM005

MMCACCCM104

MMCACCCM105

1U Rack Mounted Blank Panel

2U Rack Mounted Blank Panel

Black Grey

Product Part Numbering

Page 70: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

69

483

88

.5

483

483

44

.1

CatAC6

Cat5e

Cat6

Cat7

PRODUCT DESCRIPTION

To ensure neat and tidy installations, a range

of cable management products is available.

These products are either 19" rack mounted

or side mounted.

PRODUCT CHARACTERISTICS

1U 5 Ring Rack Mounted

Panel Width: 19” (483mm)

Panel Height: 1U (44.45mm)

Panel Depth: 65.2mm

Ring Dimensions: 60mm x 40mm x 13mm

Colour: RAL 9005 Black

or RAL 7035 Grey

Material: 1.5mm Mild Steel

1U Rack Mounted with brush

Panel Width: 19” (483mm)

Panel Height: 1U (44.1mm)

Panel Depth: 50mm

Colour: RAL 9005 Black

Material: 1.5mm Mild Steel

Side Mounted Vertical

Ring Dimensions (V): 44mm x 23mm x 50mm

Colour: RAL 9005 Black

or RAL 7035 Grey

Material: 2.5mm Mild Steel

MMCACCCM002

MMCACCCM006

MMCACCCM001

-

MMCACCCM106

MMCACCCM1011U Rack Mounted - 5 ring

1U Rack Mounted with brush

Side Mounted - Vertical

Black Grey

Product Part Numbering

Brand-Rex Copper Connectivity - Cable Management Accessories

C O P P E R A C C E S S O R I E S

Page 71: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

70

8686

86

14.4

25

CatAC6

Cat5e

Cat6

Cat7

PRODUCT DESCRIPTION

Brand-Rex supplies a comprehensive range of

plastic accessories to provide an outlet solution

for wall, trunking and floorbox applications.

These accessories have been designed to be used

in conjunction with Brand-Rex Snap-In Jacks.

All UK style faceplates are supplied with M3.5

mounting screws and are available in both

modular or low cost shuttered versions.

Backboxes can also be supplied to allow for

retrofit application where outlets are required

to be surface mounted.

Floorbox modules and blanks have been

designed to clip into a 1.0 - 2.0mm thick plate

with a standard 22 x 37mm floorbox cut-out.

PRODUCT CHARACTERISTICS

Material: ABS

Colour: White

Faceplate Type: Single or

Double Gang

Modular Range: 1 - 4 outlets

Shuttered Range: 1 or 2 outlets

MMCWDOUNI062

MMCANG0623

MMCWDO06C001

MMCANG06C3

MMCWDOUNI042

MMCBLK06C3

MMCWDOUNI040

MMCWDOUNI052

MMCWDOUNI070

MMCWDOUNI071

MMCWDOUNI030

MMCWDOUNI031

MMCSGBB32001

MMCSGBB44001

MMCDGBB32002

MMCDGBB44002

25 x 50mm Shuttered Faceplate Module

25 x 50mm Angled Faceplate Module

25 x 38mm Shuttered Floorbox Module

25 x 38mm Angled Floorbox Shuttered Module

25 x 50mm Faceplate Blank

25 x 38mm Floorbox Blank

50 x 50mm Faceplate Blank

12.5 x 50mm Faceplate Blank

86 x 86mm Single Port Shuttered Faceplate

86 x 86mm Double Port Shuttered Faceplate

86 x 86mm Single Gang Modular Faceplate

86 x 147mm Double Gang Modular Faceplate

32mm Deep, Single Gang Backbox

44mm Deep, Single Gang Backbox

32mm Deep, Double Gang Backbox

44mm Deep, Double Gang Backbox

White

Product Part Numbering

Brand-Rex Copper Connectivity - UK Styled Plastic Outlets and Accessories

C O P P E R A C C E S S O R I E S

Page 72: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

71

6250MHz

AC6500MHz

5e100MHz

14.8

PRODUCT DESCRIPTION

Brand-Rex single and double Snap-In Jack

Modules have been designed to accept the

standard Brand-Rex Snap-In Jacks and are fully

compatible with the 'Legrand Mosaic' and

our continental UNI style faceplates.

PRODUCT CHARACTERISTICS

Dimensions: 45mm x 45mm

Depth: 14.75mm

Label: White paper with

clip in clear cover

Body Material: ABS

Colour: Off White

PRODUCT DESCRIPTION

The Brand-Rex Dual angled Snap-In-Jack

module has been designed to accept two

standard Snap-In-Jacks and is fully compatible

with the standard 45 x 45mm aperture and

our continental UNI style faceplates.

PRODUCT CHARACTERISTICS

Dimensions: 45 x 45mm

Label: White paper with

clip in clear cover

Body Material: ABS

Colour: Artic White

Brand-Rex Copper Connectivity - Snap-In-Jack Modules and Dual Angled Snap-In-Jack Modules

C O P P E R A C C E S S O R I E S

Part Number

MMCUNILGS45001

MMCUNILGD45001

MMCANGLGD45001

MMCANGLGS45002

MMCANGLGD45002

MMCANGDK2453

Description

1 Way Snap-In Jack Module

2 Way Snap-In Jack Module

Dual 45 x 45mm Angled Snap-in-Jack module

Angled Snap-In-Jack Module 45 x 45mm Single Port

Angled Snap-In-Jack Module 45 x 45mm Double Port

Keystone Snap-in-Jack Faceplate Module

Product Part Numbering

Page 73: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

72

6250MHz

AC6500MHz

5e100MHz

C O P P E R A C C E S S O R I E S

PRODUCT DESCRIPTION

The Brand-Rex DIN Rail Snap-in-Jack Module

offers a connection point in the cabling

subsystem and is suitable for deployment in

residential, industrial and enterprise structured

cabling systems. The module is designed to

be easily snapped onto a DIN rail and it offers

unrivalled usability and accessibility. Multiple

modules can be aligned horizontally in a row and

the angled direction of the jacks facilitates cord

routing in a way that eases bending stresses while

maximising performance.

Snap-in-Jacks. See compatibility chart below

for details

PRODUCT CHARACTERISTICS

Dimensions: 69mm x 26mm x

67mm (D x W x H)

Label: White paper with

clip in clear cover

Body Material: Polycarbonate

Colour: Light Grey

RAL 7035

Description Part Number Colour Quantity per Pack

10GPlus Shielded Snap-in-Jack – Tool-Free

10GPlus Unshielded Jack – Tool-Free

Cat6Plus Shielded Snap-in-Jack – Tool-Free

Cat6Plus Unshielded Snap-in-Jack – Tool-Free

GigaPlus Unshielded Snap-in-Jack – Tool-Free

GigaPlus Unshielded Snap-in-Jack (Lead Frame)

AC6JAKS000

AC6JAKU002

C6CJAKS000

C6CJAKU002

GPCJAKU002

GPCJAKU013LF

-

Black

-

Black

Black

White

12

12

12

12

12

50

Compatible System Products

Brand-Rex Copper ConnectivitySingle Port DIN Rail Snap-in-Jack Module

Product Part Numbering

Description Pack Size Part Number

Single Port DIN Rail Snap-in-Jack Module 4 MMCDINSIJS8

Page 74: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

73

Cat5e

Cat6

PRODUCT DESCRIPTION

Within the standard Brand-Rex product range

is a set of standard tools for the safe and efficient

termination of copper cables. These tools are

available for both LSA and 110 style

IDC connectors.

Also available is a Brand-Rex Jack Gripper to hold

Snap-In-Jacks during termination and the range

of snap-in-jack blanks.

PRODUCT DESCRIPTION

The cable management range complements

the set of Cross-Connect components offered

by Brand-Rex. The horizontal cable organisers

can be supplied with or without legs and also

as a 19” rack mounted version.

PRODUCT CHARACTERISTICS

Dimensions

Horizontal Cable Organiser with Legs

271.8 x 46.7 x 111.0mm

Horizontal Cable Organiser without Legs

214.9 x 44.0 x 64.0mm

Horizontal Cable Organiser rack mounted

482.6 x 44.0 x 75.2mm

Organiser Material

Flame retardant thermoplastic rated

UL94V-0, off-white

Cross-Connect Cable Management & Accessories

C O P P E R A C C E S S O R I E S

Product Part Numbering

Horizontal Cable Organiser with Legs

Horizontal Cable Organiser without Legs

Horizontal Cable Organiser Rack Mounted

Vertical Cable Organiser for 110 Tower

Vertical Cable Organiser Extension for 110 Tower

IDC Punchdown Tool Handle (blades sold separately)

Punchdown Tool Blade - 110

Punchdown Tool Blade - LSA

Jack Gripper

Snap-in-Jack Blank

Snap-in-Jack Blank

CMH110L

CMH110

CMH110R

CMV110TWR

CMV110TWRE

MMCD914

MMCACC110

MMCACCLSA

MMCJH002

MMCJAKBLK2

MMCJAKBLK3

-

-

-

-

-

-

-

-

-

Black

White

Part NumberDescription Colour

Page 75: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category
Page 76: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

75

Brand-Rex is committed to a future in optical cabling

and truly believes in the benefits of optical cables for the

future requirement of both LAN and WAN networks. Why?

Here are some of the benefits of Brand-Rex Optical Systems.

Transmission Security – As optical fibre emits no

electromagnetic energy there is no opportunity

to intercept transmissions remotely.

Bandwidth – Optical fibre has a much greater data

capacity than copper, carrying more data further.

Transmission Distance – Optical systems

have much lower attenuation than copper systems

meaning that signals can be transmitted further.

No Risk of EMI or RFI – Fibre optic cables being

primarily glass have no risk of electromagnetic

or radio frequency interference.

Why Brand-Rex

Brand-Rex offers a complete panel to panel solution,

utilising all standard connectors and cable formats to

deliver a high quality reliable optical solution for your

LAN. The Brand-Rex solution includes a full range of low

fire hazard, halogen free and high performance tight

buffered and loose tube cables, a comprehensive range of

connectors, adaptors, pigtails and patch cords. The range

also includes all the features that you would expect from a

Brand-Rex system component. The complete LAN solution

is covered by the 25 year Brand-Rex channel warranty only

available from authorised Brand-Rex installation partners.

O P T I C A L S Y S T E M S

Page 77: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

76

CABLE SELECTION:

When selecting the correct cable for any

installation the first question will be of

fibre type. This is dependent upon the

transmission distance and the protocol

being adopted. Further on in this section

is a key to transmission distances on the

main fibre types for 1Gb and 10 Gb Ethernet

applications. This key is repeated on each

page as a reference.

With the choice of fibre type complete,

the selection of cable construction must

be made. There are several key questions

that must be answered in determining

cable selection.

Fibre Count -

How many fibres are required?

This should take into account future

demand and allow an element of

redundancy. The cost of installation

and associated down time will generally

outweigh the cost of additional fibre

on day one.

Additionally, good practice should be taken

into consideration. A large high fibre count

cable carrying the majority of a company's

data generates a larger risk than several

lower fibre count cables should any cable

damage occur. Diversity in routing should

also be considered in answering

this question.

Cable Properties –

What type of cable is required?

The prime function of the cable is to provide

a safe path for the fibre during and post

installation. There are a wide variety of cable

types to choose from depending on how

and where the cable is to be installed.

A summary of the main construction variants

and their intended usage is given below.

Sheath Options:

Universal Cables

These cables are designed for use both

internally and externally. They have a Low

Smoke Halogen Free (LSHF) compound

sheath that reduces the emission of toxic

fumes and reduces the spread of fire.

Outdoor Cables

These cables are designed only for external

use. They have a Low Density Polyethylene

sheath that makes the cable lighter than the

equivalent LSHF version. This combined with

reduced weight makes Outdoor Cables more

suited to the longer pulled runs into which

they are generally installed. Outdoor Cables

may enter buildings, however they must

not pass more than 3m into the building

dependant on local regulations.

Cable Options:

Premise Distribution (PDC) Cables

These cables are based on a 900 μm tight

buffered element and are generally installed

in the backbone of a building network and

direct terminated at a consolidation point.

Brand-Rex PDC cables are manufactured in

our state of the art UK based factory and

consist of up to 24 individual tight buffered

elements and distributed strength members.

The product is then sheathed with a LSFH

compound making it suitable for internal

and external applications.

Breakout and Patch Cables

To produce the building block for breakout

cables, a 900 μm tight buffered element is

sheathed with an additional layer of LSHF

compound over a layer of aramid yarns.

This forms a simplex sub unit that can be

used in the production of optical patch

cords or used for fibre to the desk (FTTD)

applications; additionally it forms the base

unit for the breakout cables.

Brand-Rex breakout cables are generally

installed within equipment rooms as rack to

rack links and are manufactured in our state

of the art UK based factory. They consist of

up to 24 simplex sub units with additional

strength members and an outer LSHF

universal sheath.

Loose Tube Cables

Loose tube cables provide for higher fibre

counts than are commonly available in tight

buffer element based products such as PDC

and breakout cables. They can generally be

installed as building or campus links and

are available in a variety of constructions

offering different mechanical performance.

The building block of a loose tube cable

is a PBT tube that contains up to 24

individually coloured optical fibres

suspended in a gel material to provide

protection and prevent water ingress.

These gel filled loose tubes are used to

produce either Unitube or Multi Loose

Tube cables.

Brand-Rex loose tube cables are

manufactured in our UK based optical facility

and are available in 4 standard variants;

1. Duct Grade

2. Rodent Resistant Glass Armoured

3. Direct Burial Grade – Single Sheath

4. Direct Burial Grade – Twin Sheath

All 4 variants are available as either Unitube

or Multi Loose tube cable. Unitube products

are available with up to 24 fibres and Multi

Loose Tube products are available with up

to 216 fibres as standard, although higher

fibre counts are available on request.

The Unitube products take a single gel filled

loose tube and apply the relevant armouring

and then either a Universal LSHF sheath or

a Polyethylene outdoor sheath. The Multi

Loose Tube products take up to 18 gel filled

loose tubes and SZ strand them around

a glass central strength member before

adding the relevant armouring and either

a Universal LSHF sheath or a Polyethylene

outdoor sheath.

O P T I C A L F I B R E R A N G E

Page 78: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

77

O62 050 OM3 OM4 BM3 BM4 008 108 208

C A B L E D O P T I C A L F I B R E S P E C I F I C AT I O N S

The tables below describe the standard fibres supplied by Brand-Rex that comply with or exceed ISO/IEC 11801 and EN50173-1 and EN50173-2

requirements, for use in high speed LAN, MAN, WAN data and telecom networks. Specific Fibre Types to customer specification are available on request.

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Part Number Identifier

IEC 60793-2 Category

ITU-T Recommendation

ISO / IEC 11801 Category

Cabled Optical Performance of Fibre

Attenuation @ 850 / 1300nm (dB/km)

Bandwidth @ 850 / 1300nm (MHz.km)

Attenuation @ 1310 / 1550nm (dB/km)

Dispersion @ 1310 / 1550nm (ps/nm.km)

Numerical Aperture

Refractive Index @ 850 / 1300 nm

Refractive Index @ 1310 / 1550nm

Geometrical Data

Core Diameter (μm)

Mode Field Diameter (μm)

Core / Cladding Concentricity Error (μm)

Overall Coating Diameter (μm)

Coating Concentricity Error (μm)

Mechanical Data

Proof Test Level

Macrobend (radius(mm) /turns/loss dB @ 1625nm)

Part Number Identifier

IEC 60793-2 Category

ITU-T Recommendation

ISO / IEC 11801 Category

Cabled Optical Performance of Fibre

Attenuation @ 850 / 1300nm (dB/km)

Bandwidth @ 850 / 1300nm (MHz.km)

EMBc (calculated Effective Modal Bandwidth) @ 850nm (MHz.km)

Numerical Aperture

Refractive Index @ 850nm

Refractive Index @ 1300nm

Geometrical Data

Core Diameter (μm)

Core / Cladding Concentricity Error (μm)

Overall Coating Diameter (μm)

Coating Concentricity Error (μm)

Mechanical Data

Proof Test Level

Macrobend (radius(mm) /turns/loss dB @ 850nm/1300nm)

062

10-A1b

n/a

OM1

≤ 3.2 / ≤ 0.8

≥ 200 / ≥ 500

n/a

n/a

0.275 +/- 0.015

1.496/1.491

n/a

62.5 +/-2

n/a

≤ 1

245 +/-10

≤ 12.5

≥ 1%

≥ 100kpsi

n/a

050

10-A1a.1

G.651.1

OM2

≤ 2.8 / ≤ 0.8

≥ 500 / ≥ 800

n/a

n/a

0.200 +/- 0.015

1.482/1.477

n/a

50 +/-2

n/a

≤ 1

245 +/-10

≤ 12.5

≥ 1%

≥ 100kpsi

n/a

OM3

10-A1a.2

G.651.1

OM3

≤ 2.8 / ≤ 0.8

≥ 1500 / ≥ 500

≥ 2000

0.200 +/- 0.015

1.482

1.477

50 +/-2

≤ 1

245 +/-10

≤ 12.5

≥ 1%

≥ 100kpsi

37.5/100/0.5/0.5

008

50-B1.3

G.652D

OS1/OS2

n/a

n/a

≤ 0.38 / ≤ 0.25

≤ 3.5 / ≤ 18

n/a

n/a

1.467/1.468

n/a

9.0

≤ 0.6

245 +/-10

≤ 12.5

≥ 1%

≥ 100kpsi

25/100/0.05

OM4

10-A1a.3

G.651.1

OM4

≤ 2.8 / ≤ 0.8

≥ 3500 / ≥ 500

≥ 4700

0.200 +/- 0.015

1.482

1.477

50 +/-2

≤ 1

245 +/-10

≤ 12.5

≥ 1%

≥ 100kpsi

37.5/100/0.5/0.5

108

50-B6_a

G.657.A1

OS1/OS2

n/a

n/a

≤ 0.38 / ≤ 0.25

≤ 3.5 / ≤ 18

n/a

n/a

1.467/1.468

n/a

9.0

≤ 0.5

245 +/-10

≤ 12.5

≥ 1%

≥ 100kpsi

15/10/0.25/1.0

10/1/0.75/1.5

BM3

10-A1a.2

G.651.1

OM3

≤ 2.8 / ≤ 0.8

≥ 1500 / ≥ 500

≥ 2000

0.200 +/- 0.015

1.482

1.477

50 +/-2

≤ 1

245 +/-10

≤ 12.5

≥ 1%

≥ 100kpsi

15/2/0.1/0.3

7.5/2/0.2/0.5

208

50-B6_a

G.657.A2

OS1/OS2

n/a

n/a

≤ 0.38 / ≤ 0.25

≤ 3.7 / ≤ 18.5

n/a

n/a

1.467/1.467

n/a

8.8

≤ 0.5

245 +/-10

≤ 12.5

≥ 1%

≥ 100kpsi

15/10/0.03

10/1/0.1/0.2

7.5/1/0.5/1.0

BM4

10-A1a.3

G.651.1

OM4

≤ 2.8 / ≤ 0.8

≥ 3500 / ≥ 500

≥ 4700

0.200 +/- 0.015

1.482

1.477

50 +/-2

≤ 1

245 +/-10

≤ 12.5

≥ 1%

≥ 100kpsi

15/2/0.1/0.3

7.5/2/0.2/0.5

Page 79: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

78

STANDARD TIGHT BUFFERED

FIBRE COLOURS:

1. Blue

2. Orange

3. Green

4. Brown

5. Grey

6. White

7. Red

8. Black

9. Yellow

10. Violet

11. Pink

12. Turquoise

13. Blue/Black

14. Orange/Black

15. Green/Black

16. Brown/Black

17. Grey/Black

18. White/Black

19. Red/Black

20. Tan/Black

21. Yellow/Black

22. Violet/Black

23. Pink/Black

24. Turquoise/Black

To serve the requirements of optical systems

customers, Brand-Rex has created a standard

range of Tight Buffered and Loose Tube

cables that will meet most requirements.

The standard specification of these cables

is described in detail on this page.

As a company that is driven by our

customers needs, Brand-Rex will always

be happy to offer non-standard products

to order based on your own specification.

This includes complex requirements ranging

from fire survival constructions to simple

requirements such as composite cables,

custom sheath colours or printing.

Please enquire about our custom

cable service.

STANDARD SHEATH

MARKINGS OPTICAL CABLES:

KEY:

Sequential length marking

Fibre Type

Cable Type

Fibre Count

Construction

Week of Manufacture

Year of Manufacture

STANDARD SHEATH COLOUR -

LOOSE TUBE AND DISTRIBUTION CABLE:

LSHF Black

Polyethylene Black

Other colours available on request subject

to minimum order quantity.

STANDARD SHEATH COLOUR -

BREAKOUT and PATCH CABLE:

Multi Mode Orange

Single Mode Yellow

Note:

and outer sheath follow this format.

on sub units on BKT cables.

STANDARD BUFFER COLOUR -

BREAKOUT and PATCH CABLE:

62.5/125 Blue

50/125 Green

OM3 Grey

OM4 Red

OS1/OS2 Yellow

O P T I C A L C A B L E M A N U FA C T U R I N G S TA N D A R D S

FibrePlus Standard

Cable Range

STANDARD FIBRE COLOURS:

1. Blue

2. Orange

3. Green

4. Brown

5. Grey

6. White

7. Red

8. Black

9. Yellow

10. Violet

11. Pink

12. Turquoise

STANDARD MULTI LOOSE TUBE

IDENTIFICATION:

1. Red

2. Green

3. Natural

4. Natural

5. Natural

6. Natural

7. Natural

8. Natural

9. Natural

10. Natural

11. Natural

12. Natural

13. Natural

14. Natural

15. Natural

16. Natural

17. Natural

18. Natural

Note: Where fillers are present in a loose

tube design, these will be used as

markers and coloured accordingly.

The colour sequence repeats for the

second layer.

Page 80: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

79

050

600600

OM4

900 550

062

300600

050

600600

OM3

900 550

00810,000

40,000

OM4

062

25300

050

83300

OM3

300 300

00810,000

40,000

550 300

Central

Computer

Room

Optical Patch Panel

Building Riser

Wall/Floor

Outlet

Terminal

Transmission Distance Identification

Fibre Type - 050

Brand-Rex standard identification characters

for fibre type used in part numbering.

Second Window - Transmission distance in metres

Standard Multi Mode 1300nm (LX)

High Grade Multi Mode 1300nm (LX4)

Single Mode 1550nm (ER)

First Window - Transmission distance in metres

Standard Multi Mode 850nm (SX)

High Grade Multi Mode 850nm (SX/SR)

Single Mode 1310nm (LR)

Standard grade

Multi Mode

OM1 62.5/125 fibre

Standard grade

Multi Mode

OM1 & OM2 50/125 fibre

Standard grade

Multi Mode

OM3 50/125 fibre

High grade

Multi Mode

OM4 50/125 fibre

Low Water Peak

Single Mode

OS1/OS2 fibre

The FibrePlus product range can be used for

conventional structured cabling systems installations

and for centralised optical fibre installations.

FibrePlus supports the cabling schemes as described

in ISO/IEC 11801 and TIA/EIA 568C.

Link transmission distances are either attenuation

limited or bandwidth limited. In attenuation limited

installations the individual loss of each component

is summed for all the parts in the link and the sum

must fall within the loss limit for the fibre type.

In bandwidth limited applications the overall reach is

given as a maximum distance supportable.

Optical Performance

The optical performance of the cable required by the

current published and new draft standards is shown in

the table below.

10 Gigabit EthernetGigabit Ethernet

Fibre Type

3.5

3.5

3.5

3.5

1.5

1.5

1.5

1.5

Maximum Attentuation(dB/km) 850nm

Maximum Attentuation(dB/km) 1300nm

062

050

OM3

OM4

Fibre Type

OS1

OS2

1.0

0.4

1.0

0.4

Maximum Attentuation(dB/km) 1310nm

Maximum Attentuation(dB/km) 1550nm

F I B R E P L U S L I N K A N D C H A N N E L T R A N S M I S S I O N D I S TA N C E S

Page 81: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

80

C A B L E P R O P E R T I E S A N D I N S TA L L AT I O N

Cable Properties

Water BlockedThe cable has been tested for water penetration in accordance with IEC 60794-1-F5 and has less than 3m penetration in a 24hr period under a 1m head of water.

Flame RetardantThe cable is sheathed in a Low Smoke Halogen Free material and offers IEC 60332-1 performance.

Non MetallicThe cable is free from metallic elements.

Suitable Installation

Internal InstallationA cable designed for installation in trunking and floor / roof voids.

Duct GradeDuct Grade Cable that can be installed into buried duct / sub duct by pulling, winching or blowing.

Direct Buried A direct burial grade of cable, which has excellent crush resistance and is designed for direct burial installation.

Rodent ResistantThe cable has armouring which offers a degree of resistance to attack from rodents.

Type of Cable

ExternalUniversalSuitable for both internal and external use.

InternalSuitable for internal use. Suitable for external use.

Fire SurvivalThis cable is sheathed in a LSHF material and offers IEC 60331-25 performance

Page 82: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

81

Tight Buffered

Type:

Design Family:

Part Number Format:

High Performance

Type:

Design Family:

Part Number Format:

Single Loose Tube (UniTube)

Type:

Design Family:

Part Number Format:

Multi Loose Tube (6 x 4 ftp)

Type:

Design Family:

Part Number Format:

Multi Loose Tube (6 x 12 ftp)

Type:

Design Family:

Part Number Format:

Multi Loose Tube (8 x 12 ftp)

Type:

Design Family:

Part Number Format:

Multi Loose Tube (12 x 12 ftp)

Type:

Design Family:

Part Number Format:

Multi Loose Tube (18 x 12 ftp)

Type:

Design Family:

Part Number Format:

Distribution

PDC

HFfffPDCxxLU

Fire Survival

UFS

EFfffUNIxxLSTALUFSRD

Duct Grade

UDU/UDE

HFfffUNIxxLU/NM

Duct Grade

MDU 01/MDE 01

HFfffSxxWLU/NM 4FT

Duct Grade

MDU 02/MDE 02

HFfffSxxWLU/NM

Duct Grade

MDU 04/MDE 04

HFfffSxxWLU/NM

Duct Grade

MDU 03/MDE 03

HFfffSxxWLU/NM

Duct Grade

MDU 05/MDE 05

HFfffSxxWLU/NM

Single Fibre Cable

SFC

HFfffSFCxxL

Glass Yarn Armoured

URU/URE

HFfffUNIxxRRLU/NM

Glass Yarn Armoured

MRU 01/MRE 01

HFfffSxxWRRLU/NM 4FT

Glass Yarn Armoured

MRU 02/MRE 02

HFfffSxxWRRLU/NM

Glass Yarn Armoured

MRU 04/MRE 04

HFfffSxxWRRLU/NM

Glass Yarn Armoured

MRU 03/MRE 03

HFfffSxxWRRLU/NM

Glass Yarn Armoured

MRU 05/MRE 05

HFfffSxxWRRLU/NM

Zip Cord

ZIP

HFfffZIPxxL

-

-

-

Direct Burial

USU/USE

HFfffUNIxxSTALU/NM

Direct Burial

MSU 01/MSE 01

HFfffSxxWSTALU/NM 4FT

Direct Burial

MSU 02/MSE 02

HFfffSxxWSTALU/NM

Direct Burial

MSU 04/MSE 04

HFfffSxxWSTALU/NM

Direct Burial

MSU 03/MSE 03

HFfffSxxWSTALU/NM

Direct Burial

MSU 05/MSE 05

HFfffSxxWSTALU/NM

Duplex Breakout

DUP

HFfffDUPxxL

-

-

-

Direct Burial

UTU/UTE

HFfffUNIxxLSTALU/NMSTANM

Direct Burial

MTU 01/MTE 01

HFfffSxxWLSTALU/NMSTANM 4FT

Direct Burial

MTU 02/MTE 02

HFfffSxxWLSTALU/NMSTANM

Direct Burial

MTU 04/MTE 04

HFfffSxxLSTALU/NMSTANM

Direct Burial

MTU 03/MTE 03

HFfffSxxWLSTALU/NMSTANM

Direct Burial

MTU 05/MTE 05

HFfffSxxWLSTALU/NMSTANM

T R A N S M I S S I O N D I S TA N C E B Y A P P L I C AT I O N

Cable Range

Page 83: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

82

Fibre Optic Link and Channel transmission distances

Brand-Rex Cabling Systems include two separate optical cable

product ranges: MicroBlo/Blolite and FibrePlus. Each set can be used

for conventional structured cabling systems installations and

for Centralised Optical Fibre installations.

Brand-Rex optical cable systems support the cabling schemes as

described in ISO/IEC 11801 and TIA/EIA 568C and EN 50173.

Link transmission distances are either attenuation limited

or bandwidth limited. In attenuation limited installations the

individual loss of each component is summed for all the parts

in the link and the sum must fall within the loss limit for the

fibre type.

The table above provides a summary of the drive distances possible

on optical fibre links per applications protocol assuming that the link

falls within the attenuation budget of the technology.

-

-

-

5,000

-

10,000

10,000

22,250

-

10,000

-

10,000

40,000

-

10,000

-

30,000

-

10,000

-

10,000

-

10,000

-

10,000

-

10,000

-

10,000

-

12,500

-

12,500

-

-

-

2,560

-

4,200

4,200

8,900

-

4,700

-

6,300

16,000

-

2,000

-

2,000

-

2,000

-

5,800

-

5,800

-

2,400

-

4,400

-

4,400

-

2,000

-

2,000

1,514

2,000

550

550

300

300

-

-

150

-

150

-

-

2,000

2,000

1,000

-

500

-

500

-

300

-

420

-

190

-

125

-

1,000

2,000

300

330

1,514

2,000

550

550

300

300

-

-

100

-

100

-

-

2,000

2,000

1,000

-

500

-

500

-

300

-

380

-

150

-

100

-

1,000

2,000

300

330

1,514

2,000

550

550

82

300

-

-

-

-

-

-

-

2,000

2,000

1,000

-

500

-

500

-

150

-

150

-

50

-

35

-

1,000

2,000

300

330

2,000

2,000

275

550

32

300

-

-

-

-

-

-

-

700

1,500

350

-

300

-

300

-

-

-

-

-

-

-

-

-

1,000

2,000

300

500

850

1300

850

1300

850

1300

1310

1550

850

1310

850

1310

1550

850

1310

850

1310

850

1310

850

1310

850

1310

850

1310

850

1310

850

1310

850

1300

850

1300

10BASE-FL

100BASE-FX

1000BASE-SX*

1000BASE-LX*

10G BASE-SR/SW*

10G BASE-LX4*

10G BASE-LR/LW*

10G BASE-ER/EW*

40GBASE-SR4*

40GBASE-LR4

100GBASE-SR10*

100GBASE-LR4

100GBASE-ER4

266 Mbit/s

531 Mbit/s

1062 Mbit/s*

1 Gbit/s FC*

2 Gbit/s FC*

4 Gbit/s FC*

8 Gbit/s FC*

16 Gbit/s FC*

155 Mbit/s

622 Mbit/s*

Ethernet

Network application

* bandwidth limited at the length stated

For extended reach support per application per cabled fibre type contact Brand-Rex

Fibre Channel

ATM

Wavelength

l

nm

OM1

62.5/125

m

OM2

50/125

m

OM3

50/125

m

OM4

50/125

m

OS1

SMF

m

OS2

SMF

m

Page 84: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

83

Distribution cables

FibrePlus distribution cables are

based around standard 900 μm tight

buffered element which offers excellent

environmental performance. The standard

range of distribution cables is available with

up to 24 fibres and the cables are designed

for use in building backbone applications.

Cable can be installed in cable conduits

by pulling or alternatively can be laid

in roof / floor voids.

The FibrePlus distribution cable range

has a Low Smoke Halogen Free sheath

and mechanical strength is derived from

strength members surrounding the

multiple tight buffered cores.

Breakout and patch cord cables

FibrePlus breakout cables are based

on standard 2.80mm single fibre cable

sub units and are designed for use in

building backbone applications or for

cross connections in equipment rooms

with suitable terminations. The cables

are designed to be pulled into conduits

or alternatively can be placed in floor /

roof void cable trays.

The single fibre cable sub unit consists of a

900 μm tight buffered fibre surrounded with

aramid yarns and a Low Smoke Halogen

Free sheath. The breakout cable takes

these sub unit, and adds additional aramid

strength members plus an outer Low Smoke

Halogen Free sheath to give a metal-free

robust and flexible breakout cable.

D I S T R I B U T I O N , B R E A K O U T & PAT C H C A B L E S

Page 85: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

84

O62 050 OM3 OM4 BM3 BM4 008 108 208

LSHF Sheath

Strength Members

900μm Tight

Buffered Fibre

Compact Design

Water Blocked Design

Low Smoke Halogen Free Sheath

PRODUCT DESCRIPTION

For building backbone and horizontal distribution

applications, the PDC cable range has been

designed to be compact and yet offer excellent

tensile performance making it suitable for a wide

range of applications. The universal construction

enables the cable to be used internally and

externally without the need for transition

cable joints.

All universal PDC cables are constructed around

the 900μm tight buffered elements which

are suitable for direct termination.

Brand-Rex Optical Cables - Universal PDCTight Buffered Premise Distribution Cables

P R E M I S E D I S T R I B U T I O N C A B L E S

Temp - Operation:

-20°c to +60°c

Temp - Storage:

-20°c to +60°c

Temp - Installation:

-15°c to +60°c

Water Penetration:

≤3m @ 24 hours

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

15

Torsion (turns / m):

5

Fire:

IEC 60332-1

4.80

5.00

5.60

5.90

22

25

29

34 920

730

640

460 50

55

65

60

75

80

95

6.50 41 1100 70 100

7.20 47 1430 75 113

8.30 62 1430 85 128

85

2 Fibre

4 Fibre

6 Fibre

8 Fibre

12 Fibre

16 Fibre

24 Fibre

Diameter

mm

Weight

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Product Data

8 Fibre

12 Fibre

16 Fibre

24 Fibre

6 Fibre

4 Fibre

2 Fibre

62.5/125 50/125 OM3 OM4 OS1/OS2

Product Part Numbering

HF 062 PDC02 LU

HF 062 PDC08 LU

HF 062 PDC06 LU

HF 062 PDC04 LU

HF 062 PDC12 LU

HF 062 PDC16 LU

HF 062 PDC24 LU

HF 050 PDC02 LU

HF 050 PDC08 LU

HF 050 PDC06 LU

HF 050 PDC04 LU

HF 050 PDC12 LU

HF 050 PDC16 LU

HF 050 PDC24 LU

HF OM3 PDC02 LU

HF OM3 PDC08 LU

HF OM3 PDC06 LU

HF OM3 PDC04 LU

HF OM3 PDC12 LU

HF OM3 PDC16 LU

HF OM3 PDC24 LU

HF OM4 PDC02 LU

HF OM4 PDC08 LU

HF OM4 PDC06 LU

HF OM4 PDC04 LU

HF OM4 PDC12 LU

HF OM4 PDC16 LU

HF OM4 PDC24 LU

HF 008 PDC02 LU

HF 008 PDC08 LU

HF 008 PDC12 LU

HF 008 PDC16 LU

HF 008 PDC24 LU

HF 008 PDC06 LU

HF 008 PDC04 LU

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 86: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

85

O62 050 OM3 OM4 BM3 BM4 008 108 208

Fibre Selection Codes

Brand-Rex Optical Cables - SFC and ZIPRuggedised Fibre Patch Cable

Rugged Construction for Indoor,

Short Run Patching

Easily configured into patch cords

Colour coded for identification

PRODUCT DESCRIPTION

Ruggedised tight buffered patching cable

is used in the manufacture of patch cords.

The robust construction is designed for short

run indoor patching or where frequent handling

is likely such as in equipment rooms, wiring

closets and at user outlets. The cable is readily

retained by industry standard connectors and

can easily be made into a patch cord.

The single fibre cable is colour coded for ease

of identification during and post installation.

62.5/125 50/125 OM3 OM4 OS1/OS2

HF 062 SFC01 L

HF 062 ZIP02 L

1 Fibre

2 Fibre

HF 050 SFC01 L

HF 050 ZIP02 L

HF OM3 SFC01 L

HF OM3 ZIP02 L

HF OM4 SFC01 L

HF OM4 ZIP02 L

HF 008 SFC01 L

HF 008 ZIP02 L

Product Part Numbering

LSHF Sheath

Aramid

Strength Members

900μm Tight Buffered Fibre

F I B R E PAT C H C A B L E

62.5/125 Blue

50/125 Green

OM3 Grey

OM4 Red

125 Yellow

62.5/125 Orange

50/125 Orange

OM3 Orange

OM4 Orange

OS1/OS2 Yellow

Non standard colour options are available on request.

Diameter

mm

Weight

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Product Data

2.80

2.80 x 5.90

8

17

200

400

30

30 (minor axis)

45

45 (major axis)

1 Fibre

2 Fibre

Temp - Operation:

-20°c to +60°c

Temp - Storage:

-20°c to +60°c

Temp - Installation:

-15°c to +60°c

PRODUCT PERFORMANCE

Crush (N):

1500

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Colour Coding - Core Colour Coding - Sheath

Page 87: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

8686

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical Cables - DUPRuggedised Duplex Breakout Cable

Rugged Construction for Indoor,

Short Run Patching

Easily configured into patch cords

Colour coded for identification

PRODUCT DESCRIPTION:

The duplex fibre cable is the building block for

ruggedised pigtail and patch cords. The robust

construction is designed for short run indoor

patching or where frequent handling is likely

such as in equipment rooms, wiring closets

and at user outlets.

3.80 x 6.60 29 400 40 (minor axis) 60 (minor axis)2 Fibre

Diameter

mm

Weight

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Product Data

LSHF Outer Sheath

LSHF Unit Sheath

Aramid Strength Members

900μm Tight Buffered Fibre

D U P L E X B R E A K O U T C A B L E

Temp - Operation:

-20°c to +60°c

Temp - Storage:

-20°c to +60°c

Temp - Installation:

-15°c to +60°c

PRODUCT PERFORMANCE:

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1HF 062 DUP02 L2 Fibre

62.5/125 50/125 OM3 8/125

HF 050 DUP02 L HF OM3 DUP02 L HF 008 DUP02 L

Product Part Numbering

62.5/125 Blue

50/125 Green

OM3 Grey

OM4 Red

8/125 Yellow

62.5/125 Orange

50/125 Orange

OM3 Orange

OM4 Orange

8/125 Yellow

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Colour Coding - Core Colour Coding - Ruggedised Unit

Page 88: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

87

FibrePlus loose tube cables are available in

unitube or multi loose tube constructions,

in three standard variants. Multi loose tube

cables are available as standard in 6 x 4 fibre

per tube, 6 x 12 fibre per tube, 8 x 12 fibre

per tube, 12 x 12 fibre per tube and 24 x 12

fibre per tubes options, offering up to

288 fibres.

The three standard variants are a general

duct grade cable; a glass yarn armoured

cable and a corrugated steel tape

armoured direct burial cable.

Loose tube cables are designed for use

in building or campus backbone applications

and can be installed by blowing, winching

or pulling into existing sub ducts or cable

conduits. Steel tape armoured products

can also be direct buried.

Bespoke loose tube cables to client

specifications with additional features

or modified mechanical performance

are available on request subject to

MOQ and lead-time.

L O O S E T U B E C A B L E S

Page 89: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

88

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical CablesMini Unitube Cable

M I N I U N I T U B E C A B L E S

Universal Mini Unitube Cable

Up to 4 fibres

Layer of non metallic strength members

White, Low Smoke, Halogen Free Sheath

PRODUCT DESCRIPTION

For Fibre to the home (FTTH) and short run

backbone applications, the Mini Unitube cable

range has been designed to be lightweight,

flexible, compact and completed with a

white sheath to be discrete in the home.

The 2 and 4 fibre variants are ideal FTTH

products, constructed with a 1.9mm gel filled

loose tube, layer of glass yarns and a Low

smoke halogen free (LSHF) outer sheath.

PRODUCT PERFORMANCE

Crush (N): 1000

Temp - Operational: -20°C to +60°C

Temp - Storage: -20°C to +70°C

Temp - Installation: -10°C to +40°C

Impact Resistance: 1J

Torsion: 20N / 10 cycles

Water Penetration: < 3 m @ 24 h

Fire Performance: IEC 60332-1-2

Corrosive & acid gases: IEC 60754

Individual Coloured

Fibres

Gel filled Loose Tube

Water-blocking

Glass Yarns

LSHF Sheath

Product Data

Mini Unitube 343.4 40011

Product Part Numbers

HF062UNI1902LU

HF062UNI1904LU

62.5/125

HF050UNI1902LU

HF050UNI1904LU

50/125

HFOM3UNI1902LU

HFOM3UNI1904LU

HFOM4UNI1902LU

HFOM4UNI1904LU

0M3 0M4

HF008UNI1902LU

HF008UNI1904LU

OS1/OS2

51

2 Fibre

4 Fibre

Fibre Count

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Diameter

mm

Weight

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Page 90: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

89

63

O62 050 OM3 OM4 BM3 BM4 008 108 208

LSHF or PE Sheath

Gel Filled Loose Tube

Water Blocking

Glass Yarns

Individual Coloured Fibres

Compact Water Blocked Design

Up to 24 Fibres

Level 1 Rodent Protection

Choice of Universal or External Sheath

PRODUCT DESCRIPTION

For building backbone applications, the duct

grade unitube cable range has been designed

to be lightweight and compact.

The 4-12 fibre product variants are constructed

around a 2.90mm gel filled loose tube, whereas

the 16-24 fibre variants use a 4.00mm loose tube.

D U C T G R A D E U N I T U B E C A B L E S

Brand-Rex Optical Cables - UDU and UDEDuct Grade Unitube Cables

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

PRODUCT PERFORMANCE

Crush (N):

1500

Impact (Nm):

3

Torsion (cycles):

5

Fire:

IEC 60332-1 (UDU only)

8 Fibre

6 Fibre

4 Fibre

GF 062 UNI24 LU

GF 062 UNI16 LU

GF 062 UNI12 LU

GF 062 UNI08 LU

GF 062 UNI06 LU

GF 062 UNI04 LU

62.5/125 50/125

GF 050 UNI24 LU

GF 050 UNI16 LU

GF 050 UNI12 LU

GF 050 UNI08 LU

GF 050 UNI06 LU

GF 050 UNI04 LU

OM3

GF OM3 UNI24 LU

GF OM3 UNI16 LU

GF OM3 UNI12 LU

GF OM3 UNI08 LU

GF OM3 UNI06 LU

GF OM3 UNI04 LU

OM4

GF OM4 UNI24 LU

GF OM4 UNI16 LU

GF OM4 UNI12 LU

GF OM4 UNI08 LU

GF OM4 UNI06 LU

GF OM4 UNI04 LU

OS1/OS2

GF 008 UNI24 LU

GF 008 UNI16 LU

GF 008 UNI12 LU

GF 008 UNI08 LU

GF 008 UNI06 LU

GF 008 UNI04 LU

Product Part Numbering - UDU - Universal

16 Fibre(2 x Bundles)

24 Fibre(2 x Bundles)

12 Fibre

8 Fibre

6 Fibre

4 Fibre

GF 062 UNI24 NM

GF 062 UNI16 NM

GF 062 UNI12 NM

GF 062 UNI08 NM

GF 062 UNI06 NM

GF 062 UNI04 NM

62.5/125 50/125

GF 050 UNI24 NM

GF 050 UNI16 NM

GF 050 UNI12 NM

GF 050 UNI08 NM

GF 050 UNI06 NM

GF 050 UNI04 NM

OM3

GF OM3 UNI24 NM

GF OM3 UNI16 NM

GF OM3 UNI12 NM

GF OM3 UNI08 NM

GF OM3 UNI06 NM

GF OM3 UNI04 NM

OM4

GF OM4 UNI24 NM

GF OM4 UNI16 NM

GF OM4 UNI12 NM

GF OM4 UNI08 NM

GF OM4 UNI06 NM

GF OM4 UNI04 NM

OS1/OS2

GF 008 UNI24 NM

GF 008 UNI16 NM

GF 008 UNI12 NM

GF 008 UNI08 NM

GF 008 UNI06 NM

GF 008 UNI04 NM

Product Part Numbering - UDE - External

16 Fibre(2 x Bundles)

24 Fibre(2 x Bundles)

Product Data

5.8

6.9

37/28

48/37 1000

1000 58

69

87

104

4 - 12 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

16 - 24 Fibre(2 x Bundles)

12 Fibre

Fibre Selection Codes The mechanical performance of these cables complies with IEC60794-3-11

Tested in accordance with IEC 60794-1-2 unless stated

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. GFOM3PDC24LU becomes GFBM3PDC24LU.

Page 91: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

90

O62 050 OM3 OM4 BM3 BM4 008 108 208

63

Brand-Rex Optical Cables - URU and UREGlass Yarn Armoured Unitube Cable

Compact Water Blocked Design

Glass Yarn Armouring

Level 2 Rodent Protection

Up to 24 fibres

Choice of Universal or External Sheath

PRODUCT DESCRIPTION

For applications where protection from rodent

attack is required, this product range offers level

2 rodent protection in the form of glass roving

armour which deters rodents from chewing

on optical cables.

The 4-12 fibre product variants are constructed

around a 2.90mm gel filled loose tube, whereas

the 16-24 fibre variants use a 4.00mm loose tube.

Product Part Numbering - URU - Universal

G L A S S A R M O U R E D U N I T U B E

LSHF or PE Sheath

Gel Filled Loose Tube

Rodent resistant

Glass Yarn Armouring

Individual Coloured Fibres

Product Part Numbering - URE - External

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (Cycles):

5

Fire:

IEC 60332-1 (URU only)

12 Fibre

8 Fibre

6 Fibre

4 Fibre

16 Fibre

(2 x Bundles)

24 Fibre(2 x Bundles)

GF 062 UNI24 RR LU

GF 062 UNI16 RR LU

GF 062 UNI12 RR LU

GF 062 UNI08 RR LU

GF 062 UNI06 RR LU

GF 062 UNI04 RR LU

62.5/125 50/125

GF 050 UNI24 RR LU

GF 050 UNI16 RR LU

GF 050 UNI12 RR LU

GF 050 UNI08 RR LU

GF 050 UNI06 RR LU

GF 050 UNI04 RR LU

OM3

GF OM3 UNI24 RR LU

GF OM3 UNI16 RR LU

GF OM3 UNI12 RR LU

GF OM3 UNI08 RR LU

GF OM3 UNI06 RR LU

GF OM3 UNI04 RR LU

OM4

GF OM4 UNI24 RR LU

GF OM4 UNI16 RR LU

GF OM4 UNI12 RR LU

GF OM4 UNI08 RR LU

GF OM4 UNI06 RR LU

GF OM4 UNI04 RR LU

OS1/OS2

GF 008 UNI24 RR LU

GF 008 UNI16 RR LU

GF 008 UNI12 RR LU

GF 008 UNI08 RR LU

GF 008 UNI06 RR LU

GF 008 UNI04 RR LU

Product Data

7.4

8.1

65/50

73/58 2800

2800 74

81

111

122

4 - 12 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

16 - 24 Fibre(2 x Bundles)

12 Fibre

8 Fibre

6 Fibre

4 Fibre

16 Fibre

(2 x Bundles)

24 Fibre(2 x Bundles)

GF 062 UNI24 RR NM

GF 062 UNI16 RR NM

GF 062 UNI12 RR NM

GF 062 UNI08 RR NM

GF 062 UNI06 RR NM

GF 062 UNI04 RR NM

62.5/125 50/125

GF 050 UNI24 RR NM

GF 050 UNI16 RR NM

GF 050 UNI12 RR NM

GF 050 UNI08 RR NM

GF 050 UNI06 RR NM

GF 050 UNI04 RR NM

OM3

GF OM3 UNI24 RR NM

GF OM3 UNI16 RR NM

GF OM3 UNI12 RR NM

GF OM3 UNI08 RR NM

GF OM3 UNI06 RR NM

GF OM3 UNI04 RR NM

OM4

GF OM4 UNI24 RR NM

GF OM4 UNI16 RR NM

GF OM4 UNI12 RR NM

GF OM4 UNI08 RR NM

GF OM4 UNI06 RR NM

GF OM4 UNI04 RR NM

OS1/OS2

GF 008 UNI24 RR NM

GF 008 UNI16 RR NM

GF 008 UNI12 RR NM

GF 008 UNI08 RR NM

GF 008 UNI06 RR NM

GF 008 UNI04 RR NM

Fibre Selection Codes The mechanical performance of these cables complies with IEC60794-3-11

Tested in accordance with IEC 60794-1-2 unless stated

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. GFOM3PDC24LU becomes GFBM3PDC24LU.

Page 92: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

91

O62 050 OM3 OM4 BM3 BM4 008 108 208

63

Brand-Rex Optical Cables - USU and USESteel Tape Armoured Unitube Cables

Steel Tape Armouring

Maximum Protection from Rodents

Choice of Universal or External Sheath

PRODUCT DESCRIPTION

For direct burial campus backbone applications,

the steel tape armoured unitube cable range

has been designed to be compact and yet offer

excellent tensile and crush performance making

it suitable for a wide range of applications.

All USU and USE steel tape armoured unitube

cables are constructed around the 4.00mm gel

filled PBT loose buffer tube. The 16-24 fibre

variants are supplied with 2 bundles within

the loose tube.

S T E E L TA P E A R M O U R E D U N I T U B E

24 Fibre

16 Fibre

12 Fibre

8 Fibre

6 Fibre

4 Fibre

GF 062 UNI24 STA LU

GF 062 UNI16 STA LU

GF 062 UNI12 STA LU

GF 062 UNI08 STA LU

GF 062 UNI06 STA LU

GF 062 UNI04 STA LU

62.5/125 50/125

GF 050 UNI24 STA LU

GF 050 UNI16 STA LU

GF 050 UNI12 STA LU

GF 050 UNI08 STA LU

GF 050 UNI06 STA LU

GF 050 UNI04 STA LU

OM3

GF OM3 UNI24 STA LU

GF OM3 UNI16 STA LU

GF OM3 UNI12 STA LU

GF OM3 UNI08 STA LU

GF OM3 UNI06 STA LU

GF OM3 UNI04 STA LU

OM4

GF OM4 UNI24 STA LU

GF OM4 UNI16 STA LU

GF OM4 UNI12 STA LU

GF OM4 UNI08 STA LU

GF OM4 UNI06 STA LU

GF OM4 UNI04 STA LU

OS1/OS2

GF 008 UNI24 STA LU

GF 008 UNI16 STA LU

GF 008 UNI12 STA LU

GF 008 UNI08 STA LU

GF 008 UNI06 STA LU

GF 008 UNI04 STA LU

Product Part Numbering - USU - Universal

Product Data

10.00

10.00

125/100

125/100 1000

1000 100

100

150

150

4 - 12 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

16 - 24 Fibre(2 x Bundles)

24 Fibre

16 Fibre

12 Fibre

8 Fibre

6 Fibre

4 Fibre

GF 062 UNI24 STA NM

GF 062 UNI16 STA NM

GF 062 UNI12 STA NM

GF 062 UNI08 STA NM

GF 062 UNI06 STA NM

GF 062 UNI04 STA NM

62.5/125 50/125

GF 050 UNI24 STA NM

GF 050 UNI16 STA NM

GF 050 UNI12 STA NM

GF 050 UNI08 STA NM

GF 050 UNI06 STA NM

GF 050 UNI04 STA NM

OM3

GF OM3 UNI24 STA NM

GF OM3 UNI16 STA NM

GF OM3 UNI12 STA NM

GF OM3 UNI08 STA NM

GF OM3 UNI06 STA NM

GF OM3 UNI04 STA NM

OM4

GF OM4 UNI24 STA NM

GF OM4 UNI16 STA NM

GF OM4 UNI12 STA NM

GF OM4 UNI08 STA NM

GF OM4 UNI06 STA NM

GF OM4 UNI04 STA NM

OS1/OS2

GF 008 UNI24 STA NM

GF 008 UNI16 STA NM

GF 008 UNI12 STA NM

GF 008 UNI08 STA NM

GF 008 UNI06 STA NM

GF 008 UNI04 STA NM

Product Part Numbering - USE - External

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns/m):

5

Fire:

IEC 60332-1 (USU only)

LSHF or PE Sheath

Gel Filled Loose Tube

Glass Yarns

Individual Coloured Fibres

Corrugated Steel Tape Armour

Fibre Selection CodesTested in accordance with IEC60794-3-11, IEC 60794-1-2 unless stated.

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. GFOM3PDC24LU becomes GFBM3PDC24LU.

Page 93: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

92

O62 050 OM3 OM4 BM3 BM4 008 108 208

63

Brand-Rex Optical Cables - UTU and UTETwin Sheath Steel Tape Armoured Unitube Cables

Twin Sheath Water Blocked Design

Steel Tape Armouring

Maximum Rodent Protection

Choice of Universal or External Sheath

PRODUCT DESCRIPTION

For direct burial campus backbone applications,

the twin sheath universal steel tape armoured

unitube cable range has been designed to be

compact and yet offer excellent tensile and crush

performance making it suitable for a wide range

of applications.

The 4-12 fibre product variants are constructed

around a 2.90mm gel filled loose tube, whereas

the 16-24 fibre variants use a 4.00mm loose tube.

Product Part Numbering - UTU - Universal

S T E E L TA P E A R M O U R E D U N I T U B E

LSHF or PE Outer Sheath

LSHF or PE Inner Sheath

Gel Filled Loose Tube

Glass Yarns

Individual Coloured Fibres

Corrugated Steel Tape ArmourProduct Data

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

(up to inner sheath)

PRODUCT PERFORMANCE

Crush (N):

5000

Impact (Nm):

15

Torsion (turns/m):

5

Fire:

IEC 60332-1 (USU2 only)

24 Fibre

16 Fibre

12 Fibre

8 Fibre

6 Fibre

4 Fibre

GF 062 UNI24 L STA LU

GF 062 UNI16 L STA LU

GF 062 UNI12 L STA LU

GF 062 UNI08 L STA LU

GF 062 UNI06 L STA LU

GF 062 UNI04 L STA LU

62.5/125 50/125

GF 050 UNI24 L STA LU

GF 050 UNI16 L STA LU

GF 050 UNI12 L STA LU

GF 050 UNI08 L STA LU

GF 050 UNI06 L STA LU

GF 050 UNI04 L STA LU

OM3

GF OM3 UNI24 L STA LU

GF OM3 UNI16 L STA LU

GF OM3 UNI12 L STA LU

GF OM3 UNI08 L STA LU

GF OM3 UNI06 L STA LU

GF OM3 UNI04 L STA LU

OM4

GF OM4 UNI24 L STA LU

GF OM4 UNI16 L STA LU

GF OM4 UNI12 L STA LU

GF OM4 UNI08 L STA LU

GF OM4 UNI06 L STA LU

GF OM4 UNI04 L STA LU

OS1/OS2

GF 008 UNI24 L STA LU

GF 008 UNI16 L STA LU

GF 008 UNI12 L STA LU

GF 008 UNI08 L STA LU

GF 008 UNI06 L STA LU

GF 008 UNI04 L STA LU

11.00

12.00

156/119

180/137 1000

1000 110

120

165

180

4 - 12 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

16 - 24 Fibre(2 x Bundles)

24 Fibre

16 Fibre

12 Fibre

8 Fibre

6 Fibre

4 Fibre

GF 062 UNI24 NM STA NM

GF 062 UNI16 NM STA NM

GF 062 UNI12 NM STA NM

GF 062 UNI08 NM STA NM

GF 062 UNI06 NM STA NM

GF 062 UNI04 NM STA NM

62.5/125 50/125

GF 050 UNI24 NM STA NM

GF 050 UNI16 NM STA NM

GF 050 UNI12 NM STA NM

GF 050 UNI08 NM STA NM

GF 050 UNI06 NM STA NM

GF 050 UNI04 NM STA NM

OM3

GF OM3 UNI24 NM STA NM

GF OM3 UNI16 NM STA NM

GF OM3 UNI12 NM STA NM

GF OM3 UNI08 NM STA NM

GF OM3 UNI06 NM STA NM

GF OM3 UNI04 NM STA NM

OM4

GF OM4 UNI24 NM STA NM

GF OM4 UNI16 NM STA NM

GF OM4 UNI12 NM STA NM

GF OM4 UNI08 NM STA NM

GF OM4 UNI06 NM STA NM

GF OM4 UNI04 NM STA NM

OS1/OS2

GF 008 UNI24 NM STA NM

GF 008 UNI16 NM STA NM

GF 008 UNI12 NM STA NM

GF 008 UNI08 NM STA NM

GF 008 UNI06 NM STA NM

GF 008 UNI04 NM STA NM

Product Part Numbering - UTE - External

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. GFOM3PDC24LU becomes GFBM3PDC24LU.

Tested in accordance with IEC60794-3-11, IEC 60794-1-2 unless stated.

Page 94: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

93

O62 050 OM3 OM4 BM3 BM4 008 108 208

63

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1(MDU only)

Product Part Numbering - MDU 01 - Universal

Product Part Numbering - MDE 01 - External

Brand-Rex Optical Cables - Universal MDU 01 and External MDE 01Duct Grade Multi Loose Tube Cable

D U C T G R A D E M U LT I L O O S E T U B E C A B L E

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

6 x 4 Fibres Per Tube

Offering Up To 24 Fibres

2.10mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For applications where a higher tensile load

is required versus that offered by unitube

constructions, the universal product range

offers compact low fibre count duct grade cable.

The product range consists of multiple loose

tubes containing up to 4 fibres and solid fillers

where required, stranded around a rigid glass

non metallic central strength member. A layer

of water blocking tape provides interstitial

water blocking.

LSHF or PE Sheath

Gel Filled

Loose Tube

Individual Coloured Fibres

Rigid Glass Central

Strength Member

Water Blocking Tape

Product Data

24 Fibre

20 Fibre

16 Fibre

12 Fibre

8 Fibre

4 Fibre

HF 062 S24 W LU 4FT

HF 062 S20 W LU 4FT

HF 062 S16 W LU 4FT

HF 062 S12 W LU 4FT

HF 062 S8 W LU 4FT

HF 062 S4 W LU 4FT

62.5/125 50/125

HF 050 S24 W LU 4FT

HF 050 S20 W LU 4FT

HF 050 S16 W LU 4FT

HF 050 S12 W LU 4FT

HF 050 S8 W LU 4FT

HF 050 S4 W LU 4FT

OM3

HF OM3 S24 W LU 4FT

HF OM3 S20 W LU 4FT

HF OM3 S16 W LU 4FT

HF OM3 S12 W LU 4FT

HF OM3 S8 W LU 4FT

HF OM3 S4 W LU 4FT

OM4

HF OM4 S24 W LU 4FT

HF OM4 S20 W LU 4FT

HF OM4 S16 W LU 4FT

HF OM4 S12 W LU 4FT

HF OM4 S8 W LU 4FT

HF OM4 S4 W LU 4FT

OS1/OS2

HF 008 S24 W LU 4FT

HF 008 S20 W LU 4FT

HF 008 S16 W LU 4FT

HF 008 S12 W LU 4FT

HF 008 S8 W LU 4FT

HF 008 S4 W LU 4FT

10.00 96/71 1500 100 1504 - 24 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

24 Fibre

20 Fibre

16 Fibre

12 Fibre

8 Fibre

4 Fibre

HF 062 S24 W NM 4FT

HF 062 S20 W NM 4FT

HF 062 S16 W NM 4FT

HF 062 S12 W NM 4FT

HF 062 S8 W NM 4FT

HF 062 S4 W NM 4FT

62.5/125 50/125

HF 050 S24 W NM 4FT

HF 050 S20 W NM 4FT

HF 050 S16 W NM 4FT

HF 050 S12 W NM 4FT

HF 050 S8 W NM 4FT

HF 050 S4 W NM 4FT

OM3

HF OM3 S24 W NM 4FT

HF OM3 S20 W NM 4FT

HF OM3 S16 W NM 4FT

HF OM3 S12 W NM 4FT

HF OM3 S8 W NM 4FT

HF OM3 S4 W NM 4FT

OM4

HF OM4 S24 W NM 4FT

HF OM4 S20 W NM 4FT

HF OM4 S16 W NM 4FT

HF OM4 S12 W NM 4FT

HF OM4 S8 W NM 4FT

HF OM4 S4 W NM 4FT

OS1/OS2

HF 008 S24 W NM 4FT

HF 008 S20 W NM 4FT

HF 008 S16 W NM 4FT

HF 008 S12 W NM 4FT

HF 008 S8 W NM 4FT

HF 008 S4 W NM 4FT

Tested in accordance with IEC 60794-1-2 unless stated

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 95: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

94

O62 050 OM3 OM4 BM3 BM4 008 108 208

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns/m):

5

Fire:

IEC 60332-1

(MDU only)

Brand-Rex Optical Cables - Universal MDU 06 and External MDE 06Universal Duct Grade Multi Loose Tube Cable

D U C T G R A D E M U LT I L O O S E T U B E C A B L E

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

5 x 12 Fibres Per Tube Offering up to 60 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For building and campus backbone applications

where higher fibre counts are required, the

product range offers a compact duct grade cable.

The product range consists of multiple loose

tubes containing up to 12 fibres and solid fillers

where required, stranded around a rigid glass non

metallic central strength member. A layer of water

blocking tape provides interstitial water blocking.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

Product Data

10.40 101/76 2000 104 15612 - 60 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

60 Fibre

48 Fibre

36 Fibre

24 Fibre

12 Fibre

GF 062 S60 W LU

GF 062 S48 W LU

GF 062 S36 W LU

GF 062 S24 W LU

GF 062 S12 W LU

62.5/125 50/125

GF 050 S60 W LU

GF 050 S48 W LU

GF 050 S36 W LU

GF 050 S24 W LU

GF 050 S12 W LU

OM3

GF OM3 S60 W LU

GF OM3 S48 W LU

GF OM3 S36 W LU

GF OM3 S24 W LU

GF OM3 S12 W LU

OM4

GF OM4 S60 W LU

GF OM4 S48 W LU

GF OM4 S36 W LU

GF OM4 S24 W LU

GF OM4 S12 W LU

OS1/OS2

GF 008 S60 W LU

GF 008 S48 W LU

GF 008 S36 W LU

GF 008 S24 W LU

GF 008 S12 W LU

Product Part Numbering - MDU 06 - Universal

60 Fibre

48 Fibre

36 Fibre

24 Fibre

12 Fibre

GF 062 S60 W NM

GF 062 S48 W NM

GF 062 S36 W NM

GF 062 S24 W NM

GF 062 S12 W NM

62.5/125 50/125

GF 050 S60 W NM

GF 050 S48 W NM

GF 050 S36 W NM

GF 050 S24 W NM

GF 050 S12 W NM

OM3

GF OM3 S60 W NM

GF OM3 S48 W NM

GF OM3 S36 W NM

GF OM3 S24 W NM

GF OM3 S12 W NM

OM4

GF OM4 S60 W NM

GF OM4 S48 W NM

GF OM4 S36 W NM

GF OM4 S24 W NM

GF OM4 S12 W NM

OS1/OS2

GF 008 S60 W NM

GF 008 S48 W NM

GF 008 S36 W NM

GF 008 S24 W NM

GF 008 S12 W NM

Product Part Numbering - MDE 06 - External

Fibre Selection Codes

LSHF or PE Sheath

Gel Filled

Loose Tube

Individual Coloured Fibres

Rigid Glass Central

Strength Member

Water Blocking Tape

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. GFOM3PDC24LU becomes GFBM3PDC24LU.

Tested in accordance with IEC60794-3-11, IEC 60794-1-2 unless stated.

Page 96: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

95

O62 050 OM3 OM4 BM3 BM4 008 108 208

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns/m):

5

Fire:

IEC 60332-1

(MDU only)

Brand-Rex Optical Cables - Universal MDU 02 and External MDE 02Universal Duct Grade Multi Loose Tube Cable

D U C T G R A D E M U LT I L O O S E T U B E C A B L E

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

6 x 12 Fibres Per Tube Offering up to 72 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For building and campus backbone applications

where higher fibre counts are required, the

product range offers a compact duct grade cable.

The product range consists of multiple loose

tubes containing up to 12 fibres and solid fillers

where required, stranded around a rigid glass non

metallic central strength member. A layer of water

blocking tape provides interstitial water blocking.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

LSHF or PE Sheath

Gel Filled

Loose Tube

Individual Coloured Fibres

Rigid Glass Central

Strength Member

Water Blocking Tape

Product Data

11.20 118/90 2700 112 16872 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

72 Fibre GF 062 S72 W LU

62.5/125 50/125

GF 050 S72 W LU

OM3

GF OM3 S72 W LU

OM4

GF OM4 S72 W LU

OS1/OS2

GF 008 S72 W LU

Product Part Numbering - MDU 02 - Universal

72 Fibre

Product Part Numbering - MDE 02 - External

Fibre Selection Codes

62.5/125

GF 062 S72 W NM

50/125

GF 050 S72 W NM

OM3

GF OM3 S72 W NM

OM4

GF OM4 S72 W NM

OS1/OS2

GF 008 S72 W NM

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. GFOM3PDC24LU becomes GFBM3PDC24LU.

Tested in accordance with IEC60794-3-11, IEC 60794-1-2 unless stated.

Page 97: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

96

O62 050 OM3 OM4 BM3 BM4 008 108 208

LSHF or PE Sheath

Gel Filled

Loose Tube

Individual Coloured Fibres

Rigid Glass Central

Strength Member

Water Blocking Tape

Brand-Rex Optical Cables - Universal MDU 04 and External MDE 04Universal Duct Grade Multi Loose Tube Cable

D U C T G R A D E M U LT I L O O S E T U B E C A B L E

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

8 x 12 Fibres Per Tube Offering up to 96 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For building and campus backbone applications

where higher fibre counts are required, the

product range offers a compact duct grade cable.

The product range consists of multiple loose

tubes containing up to 12 fibres and solid fillers

where required, stranded around a rigid glass non

metallic central strength member. A layer of water

blocking tape provides interstitial water blocking.

Product Data

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MDU only)

Product Part Numbering - MDU 04 - Universal

12.60 150/118 3000 126 18984 - 96 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

84 Fibre

96 Fibre

62.5/125

HF 062 S84 W LU

HF 062 S96 W LU

50/125

HF 050 S84 W LU

HF 050 S96 W LU

OM3

HF OM3 S84 W LU

HF OM3 S96 W LU

OM4

HF OM4 S84 W LU

HF OM4 S96 W LU

OS1/OS2

HF 008 S84 W LU

HF 008 S96 W LU

Product Part Numbering - MDE 04 - External

84 Fibre

96 Fibre

62.5/125

HF 062 S84 W NM

HF 062 S96 W NM

50/125

HF 050 S84 W NM

HF 050 S96 W NM

OM3

HF OM3 S84 W NM

HF OM3 S96 W NM

OM4

HF OM4 S84 W NM

HF OM4 S96 W NM

OS1/OS2

HF 008 S84 W NM

HF 008 S96 W NM

Tested in accordance with IEC 60794-1-2 unless stated

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 98: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

97

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical Cables - Universal MDU 03 and External MDE 03Duct Grade Multi Loose Tube Cable

144 Fibre

132 Fibre

120 Fibre

108 Fibre

HF 062 S144 W LU

HF 062 S132 W LU

HF 062 S120 W LU

HF 062 S108 W LU

62.5/125 50/125

HF 050 S144 W LU

HF 050 S132 W LU

HF 050 S120 W LU

HF 050 S108 W LU

OM3

HF OM3 S144 W LU

HF OM3 S132 W LU

HF OM3 S120 W LU

HF OM3 108 W LU

OM4

HF OM4 S144 W LU

HF OM4 S132 W LU

HF OM4 S120 W LU

HF OM4 108 W LU

OS1/OS2

HF 008 S144 W LU

HF 008 S132 W LU

HF 008 S120 W LU

HF 008 S108 W LU

Product Part Numbering - MDU 03 - Universal

D U C T G R A D E M U LT I L O O S E T U B E C A B L E

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

12 x 12 Fibres Per Tube Offering up to 144 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For higher fibre count building and campus

backbone applications the product range

delivers up to 144 fibres in a compact duct grade

construction. The product range consists of

multiple 2.50mm loose tubes containing up to

12 fibres and solid fillers where required, stranded

around a sheathed rigid glass non metallic central

strength member. A layer of water blocking tape

provides interstitial water blocking.

Product Part Numbering - MDE 03 - External

LSHF or PE Sheath

Gel Filled

Loose Tube

Individual Coloured Fibres

Water Blocking Tape

Central Strength Member Sheath

Rigid Glass Central Strength Member

Product Data

16.00 222/180 2000 160 240108 - 144 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MDU only)

144 Fibre

132 Fibre

120 Fibre

108 Fibre

HF 062 S144 W NM

HF 062 S132 W NM

HF 062 S120 W NM

HF 062 S108 W NM

62.5/125 50/125

HF 050 S144 W NM

HF 050 S132 W NM

HF 050 S120 W NM

HF 050 S108 W NM

OM3

HF OM3 S144 W NM

HF OM3 S132 W NM

HF OM3 S120 W NM

HF OM3 108 W NM

OM4

HF OM4 S144 W NM

HF OM4 S132 W NM

HF OM4 S120 W NM

HF OM4 108 W NM

OS1/OS2

HF 008 S144 W NM

HF 008 S132 W NM

HF 008 S120 W NM

HF 008 S108 W NM

Tested in accordance with IEC 60794-1-2 unless stated

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 99: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

98

O62 050 OM3 OM4 BM3 BM4 008 108 208

LSHF or PE Sheath

Gel Filled

Loose Tube

Individual Coloured Fibres

Water Blocking Tape

Rigid Glass Central Strength Member

Brand-Rex Optical Cables - Universal MDU 05 and External MDE 05Duct Grade Multi Loose Tube Cable

D U C T G R A D E M U LT I L O O S E T U B E C A B L E

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

18 x 12 Fibres Per Tube Offering up to 216 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For higher fibre count building and campus

backbone applications the product range

delivers up to 216 fibres in a compact duct grade

construction. The product range consists of

multiple 2.50mm loose tubes containing up to

12 fibres and solid fillers where required, stranded

around a sheathed rigid glass non metallic central

strength member. A layer of water blocking tape

provides interstitial water blocking.

Tested in accordance with IEC 60794-1-2 unless stated

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MDU only)

192 Fibre

180 Fibre

168 Fibre

156 Fibre

Product Part Numbering - MDU 05 - Universal

204 Fibre

216 Fibre

HF 062 S192 W LU

HF 062 S180 W LU

HF 062 S168 W LU

HF 062 S156 W LU

62.5/125

HF 062 S204 W LU

HF 062 S216 W LU

50/125

HF 050 S192 W LU

HF 050 S180 W LU

HF 050 S168 W LU

HF 050 S156 W LU

HF 050 S204 W LU

HF 050 S216 W LU

OM3

HF OM3 S192 W LU

HF OM3 S180 W LU

HF OM3 S168 W LU

HF OM3 S156 W LU

HF OM3 S204 W LU

HF OM3 S216 W LU

OM4

HF OM4 S192 W LU

HF OM4 S180 W LU

HF OM4 S168 W LU

HF OM4 S156 W LU

HF OM4 S204 W LU

HF OM4 S216 W LU

OS1/OS2

HF 008 S192 W LU

HF 008 S180 W LU

HF 008 S168 W LU

HF 008 S156 W LU

HF 008 S204 W LU

HF 008 S216 W LU

192 Fibre

180 Fibre

168 Fibre

156 Fibre

Product Part Numbering - MDE 05 - External

216 Fibre

204 Fibre

HF 062 S192 W NM

HF 062 S180 W NM

HF 062 S168 W NM

HF 062 S156 W NM

62.5/125

HF 062 S204 W NM

HF 062 S216 W NM

50/125

HF 050 S192 W NM

HF 050 S180 W NM

HF 050 S168 W NM

HF 050 S156 W NM

HF 050 S204 W NM

HF 050 S216 W NM

OM3

HF OM3 S192 W NM

HF OM3 S180 W NM

HF OM3 S168 W NM

HF OM3 156 W NM

HF OM3 S204 W NM

HF OM3 S216 W NM

OM4

HF OM4 S192 W NM

HF OM4 S180 W NM

HF OM4 S168 W NM

HF OM4 156 W NM

HF OM4 S204 W NM

HF OM4 S216 W NM

OS1/OS2

HF 008 S192 W NM

HF 008 S180 W NM

HF 008 S168 W NM

HF 008 S156 W NM

HF 008 S204 W NM

HF 008 S216 W NM

Product Data

16.50 220/177 2000 165 248156 - 216 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 100: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

99

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical Cables - Universal MRU 01 and External MRE 01Glass Yarn Armoured Rodent Resistant Multi Loose Tube Cable

Product Part Numbering - MRU 01 - Universal

G L A S S YA R N A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

24 Fibre

20 Fibre

16 Fibre

12 Fibre

8 Fibre

4 Fibre

HF 062 S24 W RR LU 4FT

HF 062 S20 W RR LU 4FT

HF 062 S16 W RR LU 4FT

HF 062 S12 W RR LU 4FT

HF 062 S8 W RR LU 4FT

HF 062 S4 W RR LU 4FT

62.5/125 50/125

HF 050 S24 W RR LU 4FT

HF 050 S20 W RR LU 4FT

HF 050 S16 W RR LU 4FT

HF 050 S12 W RR LU 4FT

HF 050 S8 W RR LU 4FT

HF 050 S4 W RR LU 4FT

OM3

HF OM3 S24 W RR LU 4FT

HF OM3 S20 W RR LU 4FT

HF OM3 S16 W RR LU 4FT

HF OM3 S12 W RR LU 4FT

HF OM3 S8 W RR LU 4FT

HF OM3 S4 W RR LU 4FT

OM4

HF OM4 S24 W RR LU 4FT

HF OM4 S20 W RR LU 4FT

HF OM4 S16 W RR LU 4FT

HF OM4 S12 W RR LU 4FT

HF OM4 S8 W RR LU 4FT

HF OM4 S4 W RR LU 4FT

OS1/OS2

HF 008 S24 W RR LU 4FT

HF 008 S20 W RR LU 4FT

HF 008 S16 W RR LU 4FT

HF 008 S12 W RR LU 4FT

HF 008 S8 W RR LU 4FT

HF 008 S4 W RR LU 4FT

11.1 149/118 4400 110 1674 - 24 Fibre

24 Fibre

20 Fibre

16 Fibre

12 Fibre

8 Fibre

4 Fibre

HF 062 S24 W RR NM 4FT

HF 062 S20 W RR NM 4FT

HF 062 S16 W RR NM 4FT

HF 062 S12 W RR NM 4FT

HF 062 S8 W RR NM 4FT

HF 062 S4 W RR NM 4FT

62.5/125 50/125

HF 050 S24 W RR NM 4FT

HF 050 S20 W RR NM 4FT

HF 050 S16 W RR NM 4FT

HF 050 S12 W RR NM 4FT

HF 050 S8 W RR NM 4FT

HF 050 S4 W RR NM 4FT

OM3

HF OM3 S24 W RR NM 4FT

HF OM3 S20 W RR NM 4FT

HF OM3 S16 W RR NM 4FT

HF OM3 S12 W RR NM 4FT

HF OM3 S8 W RR NM 4FT

HF OM3 S4 W RR NM 4FT

OM4

HF OM4 S24 W RR NM 4FT

HF OM4 S20 W RR NM 4FT

HF OM4 S16 W RR NM 4FT

HF OM4 S12 W RR NM 4FT

HF OM4 S8 W RR NM 4FT

HF OM4 S4 W RR NM 4FT

OS1/OS2

HF 008 S24 W RR NM 4FT

HF 008 S20 W RR NM 4FT

HF 008 S16 W RR NM 4FT

HF 008 S12 W RR NM 4FT

HF 008 S8 W RR NM 4FT

HF 008 S4 W RR NM 4FT

Product Part Numbering - MRE 01 - External

Tested in accordance with IEC 60794-1-2 unless stated

Glass Yarn Armouring for Rodent Resistance

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

2.10mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For applications where protection from rodent

attack is required and a higher tensile load

is required, exists the universal MRR product

range offers rodent protection in the form

of glass roving armour which deters rodents

from chewing on optical cables. The product

range consists of multiple 2.10mm loose tubes

containing up to 4 fibres and solid fillers where

required, stranded around a rigid glass non

metallic central strength member. A layer

of water blocking tape provides interstitial

water blocking.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

LSHF or PE Sheath

Gel Filled

Loose Tube

Rodent Resistant

Glass Yarn Armouring

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MRU only)

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 101: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

100

O62 050 OM3 OM4 BM3 BM4 008 108 208

G L A S S YA R N A R M O U R E D M U LT I L O O S E T U B E C A B L E

Brand-Rex Optical Cables - Universal MRU 02 and External MRE 02Glass Yarn Armoured Rodent Resistant Multi Loose Tube Cable

Product Part Numbering - MRU 02 - Universal

Glass Yarn Armouring for Rodent Resistance

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For applications where protection from rodent

attack and higher fibre counts are required, the

universal product range offers rodent protection

in the form of glass roving armour which deters

rodents from chewing on optical cables.

The product range consists of multiple 2.50mm

loose tubes containing up to 12 fibres and solid

fillers where required, stranded around a rigid

glass non metallic central strength member.

A layer of water blocking tape provides

interstitial water blocking.

LSHF or PE Sheath

Gel Filled

Loose Tube

Rodent Resistant

Glass Yarn Armouring

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

Product Part Numbering - MRE 02 - External

Product Data

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MRU only)

72 Fibre

60 Fibre

48 Fibre

36 Fibre

24 Fibre

12 Fibre

HF 062 S72 W RR LU

HF 062 S60 W RR LU

HF 062 S48 W RR LU

HF 062 S36 W RR LU

HF 062 S24 W RR LU

HF 062 S12 W RR LU

62.5/125 50/125

HF 050 S72 W RR LU

HF 050 S60 W RR LU

HF 050 S48 W RR LU

HF 050 S36 W RR LU

HF 050 S24 W RR LU

HF 050 S12 W RR LU

OM3

HF OM3 S72 W RR LU

HF OM3 S60 W RR LU

HF OM3 S48 W RR LU

HF OM3 S36 W RR LU

HF OM3 S24 W RR LU

HF OM3 S12 W RR LU

OM4

HF OM4 S72 W RR LU

HF OM4 S60 W RR LU

HF OM4 S48 W RR LU

HF OM4 S36 W RR LU

HF OM4 S24 W RR LU

HF OM4 S12 W RR LU

OS1/OS2

HF 008 S72 W RR LU

HF 008 S60 W RR LU

HF 008 S48 W RR LU

HF 008 S36 W RR LU

HF 008 S24 W RR LU

HF 008 S12 W RR LU

12.2 171/137 5500 122 18312 - 72 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Tested in accordance with IEC 60794-1-2 unless stated

72 Fibre

60 Fibre

48 Fibre

36 Fibre

24 Fibre

12 Fibre

HF 062 S72 W RR NM

HF 062 S60 W RR NM

HF 062 S48 W RR NM

HF 062 S36 W RR NM

HF 062 S24 W RR NM

HF 062 S12 W RR NM

62.5/125 50/125

HF 050 S72 W RR NM

HF 050 S60 W RR NM

HF 050 S48 W RR NM

HF 050 S36 W RR NM

HF 050 S24 W RR NM

HF 050 S12 W RR NM

OM3

HF OM3 S72 W RR NM

HF OM3 S60 W RR NM

HF OM3 S48 W RR NM

HF OM3 S36 W RR NM

HF OM3 S24 W RR NM

HF OM3 S12 W RR NM

OM4

HF OM4 S72 W RR NM

HF OM4 S60 W RR NM

HF OM4 S48 W RR NM

HF OM4 S36 W RR NM

HF OM4 S24 W RR NM

HF OM4 S12 W RR NM

OS1/OS2

HF 008 S72 W RR NM

HF 008 S60 W RR NM

HF 008 S48 W RR NM

HF 008 S36 W RR NM

HF 008 S24 W RR NM

HF 008 S12 W RR NM

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 102: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

101

O62 050 OM3 OM4 BM3 BM4 008 108 208

G L A S S YA R N A R M O U R E D M U LT I L O O S E T U B E C A B L E

Brand-Rex Optical Cables - Universal MRU 04 and External MRE 04Glass Yarn Armoured Rodent Resistant Multi Loose Tube Cable

Glass Yarn Armouring for Rodent Resistance

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For applications where protection from rodent

attack and higher fibre counts are required,

the universal product range offers rodent

protection in the form of glass roving armour

which deters rodents from chewing on optical

cables. The product range consists of multiple

2.50mm loose tubes containing up to 12 fibres

and solid fillers where required, stranded around

a rigid glass non metallic central strength

member. A layer of water blocking tape

provides interstitial water blocking.

LSHF or PE Sheath

Gel Filled

Loose Tube

Rodent Resistant

Glass Yarn Armouring

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

Product Data

Product Part Numbering - MRU 04 - Universal

Product Part Numbering - MRE 04 - External

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MRU only)

13.5 200/164 5500 135 19884 - 96 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

84 Fibre

62.5/125

HF 062 S84 W RR LU

HF 062 S96 W RR LU96 Fibre

50/125

HF 050 S84 W RR LU

HF 050 S96 W RR LU

OM3

HF OM3 S84 W RR LU

HF OM3 S96 W RR LU

OM4

HF OM4 S84 W RR LU

HF OM4 S96 W RR LU

OS1/OS2

HF 008 S84 W RR LU

HF 008 S96 W RR LU

84 Fibre

96 Fibre

62.5/125

HF 062 S84 W RR NM

HF 062 S96 W RR NM

50/125

HF 050 S84 W RR NM

HF 050 S96 W RR NM

OM3

HF OM3 S84 W RR NM

HF OM3 S96 W RR NM

OM4

HF OM4 S84 W RR NM

HF OM4 S96 W RR NM

OS1/OS2

HF 008 S84 W RR NM

HF 008 S96 W RR NM

Tested in accordance with IEC 60794-1-2 unless stated

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 103: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

102

O62 050 OM3 OM4 BM3 BM4 008 108 208

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MRU only)

Brand-Rex Optical Cables - Universal MRU 03 and External MRE 03Glass Yarn Armoured Rodent Resistant Multi Loose Tube Cable

Product Part Numbering - MRU 03 - Universal

Glass Yarn Armouring for Rodent Resistance

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

12 x 12 Fibres Per Tube Offering up to 144 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For applications where protection from rodent

attack and higher fibre counts are required,

the universal product range offers rodent

protection in the form of glass roving armour

that deters rodents from chewing on optical

cables. The product range consists of multiple

2.50mm loose tubes containing up to 12 fibres

and solid fillers where required, stranded around

a sheathed rigid glass non metallic central

strength member. A layer of water blocking

tape provides interstitial water blocking.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

LSHF or PE Sheath

Gel Filled

Loose Tube

Rodent Resistant

Glass Yarn Armouring

Individual Coloured Fibres

Central Strength Member Sheath

Rigid Glass Central Strength Member

Water Blocking Tape

G L A S S YA R N A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

16.7 279/230 6000 167 251108 - 144 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

62.5/125

HF 062 S144 W RR LU

HF 062 S132 W RR LU

HF 062 S120 W RR LU

HF 062 S108 W RR LU

144 Fibre

132 Fibre

120 Fibre

108 Fibre

50/125

HF 050 S144 W RR LU

HF 050 S132 W RR LU

HF 050 S120 W RR LU

HF 050 S108 W RR LU

OM3

HF OM3 S144 W RR LU

HF OM3 S132 W RR LU

HF OM3 S120 W RR LU

HF OM3 S108 W RR LU

OM4

HF OM4 S144 W RR LU

HF OM4 S132 W RR LU

HF OM4 S120 W RR LU

HF OM4 S108 W RR LU

OS1/OS2

HF 008 S144 W RR LU

HF 008 S132 W RR LU

HF 008 S120 W RR LU

HF 008 S108 W RR LU

144 Fibre

132 Fibre

120 Fibre

108 Fibre

HF 062 S144 W RR NM

HF 062 S132 W RR NM

HF 062 S120 W RR NM

HF 062 S108 W RR NM

62.5/125 50/125

HF 050 S144 W RR NM

HF 050 S132 W RR NM

HF 050 S120 W RR NM

HF 050 S108 W RR NM

OM3

HF OM3 S144 W RR NM

HF OM3 S132 W RR NM

HF OM3 S120 W RR NM

HF OM3 S108 W RR NM

OM4

HF OM4 S144 W RR NM

HF OM4 S132 W RR NM

HF OM4 S120 W RR NM

HF OM4 S108 W RR NM

OS1/OS2

HF 008 S144 W RR NM

HF 008 S132 W RR NM

HF 008 S120 W RR NM

HF 008 S108 W RR NM

Product Part Numbering - MRE 03 - External

Tested in accordance with IEC 60794-1-2 unless stated

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 104: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

103

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical Cables - Universal MRU 05 and External MRE 05Glass Yarn Armoured Rodent Resistant Multi Loose Tube Cable

Glass Yarn Armouring for Rodent Resistance

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

18 x 12 Fibres Per Tube Offering up to 216 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For applications where protection from rodent

attack and higher fibre counts are required,

the universal product range offers rodent

protection in the form of glass roving armour

that deters rodents from chewing on optical

cables. The product range consists of multiple

2.50mm loose tubes containing up to 12 fibres

and solid fillers where required, stranded around

a sheathed rigid glass non metallic central

strength member. A layer of water blocking

tape provides interstitial water blocking.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

G L A S S YA R N A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

PRODUCT PERFORMANCE

Crush (N):

2000

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MRU only)

LSHF or PE Sheath

Gel Filled

Loose Tube

Rodent Resistant

Glass Yarn Armouring

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape17.2 294/250 5500 172 258156 - 216 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Tested in accordance with IEC 60794-1-2 unless stated

192 Fibre

180 Fibre

168 Fibre

156 Fibre

Product Part Numbering - MRU 05 - Universal

216 Fibre

204 Fibre

HF 062 S192 W RR LU

HF 062 S180 W RR LU

HF 062 S168 W RR LU

HF 062 S156 W RR LU

62.5/125

HF 062 S204 W RR LU

HF 062 S216 W RR LU

50/125

HF 050 S192 W RR LU

HF 050 S180 W RR LU

HF 050 S168 W RR LU

HF 050 S156 W RR LU

HF 050 S204 W RR LU

HF 050 S216 W RR LU

OM3

HF OM3 S192 W RR LU

HF OM3 S180 W RR LU

HF OM3 S168 W RR LU

HF OM3 S156 W RR LU

HF OM3 S204 W RR LU

HF OM3 S216 W RR LU

OM4

HF OM4 S192 W RR LU

HF OM4 S180 W RR LU

HF OM4 S168 W RR LU

HF OM4 S156 W RR LU

HF OM4 S204 W RR LU

HF OM4 S216 W RR LU

OS1/OS2

HF 008 S192 W RR LU

HF 008 S180 W RR LU

HF 008 S168 W RR LU

HF 008 S156 W RR LU

HF 008 S204 W RR LU

HF 008 S216 W RR LU

192 Fibre

180 Fibre

168 Fibre

156 Fibre

Product Part Numbering - MRE 05 - External

216 Fibre

204 Fibre

HF 062 S192 W RR NM

HF 062 S180 W RR NM

HF 062 S168 W RR NM

HF 062 S156 W RR NM

62.5/125

HF 062 S204 W RR NM

HF 062 S216 W RR NM

50/125

HF 050 S192 W RR NM

HF 050 S180 W RR NM

HF 050 S168 W RR NM

HF 050 S156 W RR NM

HF 050 S204 W RR NM

HF 050 S216 W RR NM

OM3

HF OM3 S192 W RR NM

HF OM3 S180 W RR NM

HF OM3 S168 W RR NM

HF OM3 S156 W RR NM

HF OM3 S204 W RR NM

HF OM3 S216 W RR NM

OM4

HF OM4 S192 W RR NM

HF OM4 S180 W RR NM

HF OM4 S168 W RR NM

HF OM4 S156 W RR NM

HF OM4 S204 W RR NM

HF OM4 S216 W RR NM

OS1/OS2

HF 008 S192 W RR NM

HF 008 S180 W RR NM

HF 008 S168 W RR NM

HF 008 S156 W RR NM

HF 008 S204 W RR NM

HF 008 S216 W RR NM

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 105: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

104

O62 050 OM3 OM4 BM3 BM4 008 108 208 Tested in accordance with IEC 60794-1-2 unless stated

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

6 x 4 Fibres Per Tube Offering up to 24 Fibres

2.10mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For applications where a higher tensile load

is required versus that offered by unitube

constructions, this product range offers a

compact low fibre count direct burial grade cable.

The product range consists of multiple 2.10mm

loose tubes containing up to 4 fibres and solid

fillers where required, stranded around a rigid

glass non metallic central strength member.

A layer of water blocking tape provides interstitial

water blocking and a layer of corrugated steel

tape armour provides additional crush resistance.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MSU only)

Brand-Rex Optical Cables - Universal MSU 01 and External MSE 01Direct Burial Steel Tape Armoured Multi Loose Tube Cable

Product Part Numbering - MSU 01 - Universal

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

12.20 190 / 153 1500 122 1834 - 24 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

24 Fibre

20 Fibre

16 Fibre

12 Fibre

8 Fibre

4 Fibre

HF 062 S24 W STA LU 4FT

HF 062 S20 W STA LU 4FT

HF 062 S16 W STA LU 4FT

HF 062 S12 W STA LU 4FT

HF 062 S8 W STA LU 4FT

HF 062 S4 W STA LU 4FT

62.5/125 50/125

HF 050 S24 W STA LU 4FT

HF 050 S20 W STA LU 4FT

HF 050 S16 W STA LU 4FT

HF 050 S12 W STA LU 4FT

HF 050 S8 W STA LU 4FT

HF 050 S4 W STA LU 4FT

OM3

HF OM3 S24 W STA LU 4FT

HF OM3 S20 W STA LU 4FT

HF OM3 S16 W STA LU 4FT

HF OM3 S12 W STA LU 4FT

HF OM3 S8 W STA LU 4FT

HF OM3 S4 W STA LU 4FT

OM4

HF OM4 S24 W STA LU 4FT

HF OM4 S20 W STA LU 4FT

HF OM4 S16 W STA LU 4FT

HF OM4 S12 W STA LU 4FT

HF OM4 S8 W STA LU 4FT

HF OM4 S4 W STA LU 4FT

OS1/OS2

HF 008 S24 W STA LU 4FT

HF 008 S20 W STA LU 4FT

HF 008 S16 W STA LU 4FT

HF 008 S12 W STA LU 4FT

HF 008 S8 W STA LU 4FT

HF 008 S4 W STA LU 4FT

24 Fibre

20 Fibre

16 Fibre

12 Fibre

8 Fibre

4 Fibre

HF 062 S24 W STA NM 4FT

HF 062 S20 W STA NM 4FT

HF 062 S16 W STA NM 4FT

HF 062 S12 W STA NM 4FT

HF 062 S8 W STA NM 4FT

HF 062 S4 W STA NM 4FT

62.5/125 50/125

HF 050 S24 W STA NM 4FT

HF 050 S20 W STA NM 4FT

HF 050 S16 W STA NM 4FT

HF 050 S12 W STA NM 4FT

HF 050 S8 W STA NM 4FT

HF 050 S4 W STA NM 4FT

OM3

HF OM3 S24 W STA NM 4FT

HF OM3 S20 W STA NM 4FT

HF OM3 S16 W STA NM 4FT

HF OM3 S12 W STA NM 4FT

HF OM3 S8 W STA NM 4FT

HF OM3 S4 W STA NM 4FT

OM4

HF OM4 S24 W STA NM 4FT

HF OM4 S20 W STA NM 4FT

HF OM4 S16 W STA NM 4FT

HF OM4 S12 W STA NM 4FT

HF OM4 S8 W STA NM 4FT

HF OM4 S4 W STA NM 4FT

OS1/OS2

HF 008 S24 W STA NM 4FT

HF 008 S20 W STA NM 4FT

HF 008 S16 W STA NM 4FT

HF 008 S12 W STA NM 4FT

HF 008 S8 W STA NM 4FT

HF 008 S4 W STA NM 4FT

Product Part Numbering - MSE 01 - External

LSHF or PE Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 106: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

105

O62 050 OM3 OM4 BM3 BM4 008 108 208

72 Fibre

60 Fibre

48 Fibre

36 Fibre

24 Fibre

12 Fibre

HF 062 S72 W STA NM

HF 062 S60 W STA NM

HF 062 S48 W STA NM

HF 062 S36 W STA NM

HF 062 S24 W STA NM

HF 062 S12 W STA NM

62.5/125 50/125

HF 050 S72 W STA NM

HF 050 S60 W STA NM

HF 050 S48 W STA NM

HF 050 S36 W STA NM

HF 050 S24 W STA NM

HF 050 S12 W STA NM

OM3

HF OM3 S72 W STA NM

HF OM3 S60 W STA NM

HF OM3 S48 W STA NM

HF OM3 S36 W STA NM

HF OM3 S24 W STA NM

HF OM3 S12 W STA NM

OM4

HF OM4 S72 W STA NM

HF OM4 S60 W STA NM

HF OM4 S48 W STA NM

HF OM4 S36 W STA NM

HF OM4 S24 W STA NM

HF OM4 S12 W STA NM

OS1/OS2

HF 008 S72 W STA NM

HF 008 S60 W STA NM

HF 008 S48 W STA NM

HF 008 S36 W STA NM

HF 008 S24 W STA NM

HF 008 S12 W STA NM

Product Part Numbering - MSE 02 - External

Brand-Rex Optical Cables - Universal MSU 02 and MSE 02Direct Burial Steel Tape Armoured Multi Loose Tube Cable

72 Fibre

60 Fibre

48 Fibre

36 Fibre

24 Fibre

12 Fibre

HF 062 S72 W STA LU

HF 062 S60 W STA LU

HF 062 S48 W STA LU

HF 062 S36 W STA LU

HF 062 S24 W STA LU

HF 062 S12 W STA LU

62.5/125 50/125

HF 050 S72 W STA LU

HF 050 S60 W STA LU

HF 050 S48 W STA LU

HF 050 S36 W STA LU

HF 050 S24 W STA LU

HF 050 S12 W STA LU

OM3

HF OM3 S72 W STA LU

HF OM3 S60 W STA LU

HF OM3 S48 W STA LU

HF OM3 S36 W STA LU

HF OM3 S24 W STA LU

HF OM3 S12 W STA LU

OM4

HF OM4 S72 W STA LU

HF OM4 S60 W STA LU

HF OM4 S48 W STA LU

HF OM4 S36 W STA LU

HF OM4 S24 W STA LU

HF OM4 S12 W STA LU

OS1/OS2

HF 008 S72 W STA LU

HF 008 S60 W STA LU

HF 008 S48 W STA LU

HF 008 S36 W STA LU

HF 008 S24 W STA LU

HF 008 S12 W STA LU

Product Part Numbering - MSU 02 - Universal

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

6 x 12 Fibres Per Tube Offering up to 72 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For direct burial applications, the single sheathed

product range offers up to 72 fibres in a compact

and relatively flexible construction. The product

range consists of multiple 2.50mm loose tubes

containing up to 12 fibres and solid fillers where

required, stranded around a rigid glass non

metallic central strength member. A layer of

water blocking tape provides interstitial water

blocking and a layer of steel tape armour provides

additional crush resistance.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

LSHF or PE Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

13.40 227/185 2000 134 20112 - 72 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MSU only)

Tested in accordance with IEC 60794-1-2 unless stated

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 107: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

106

O62 050 OM3 OM4 BM3 BM4 008 108 208

LSHF or PE Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

Brand-Rex Optical Cables - Universal MSU 04 and MSE 04Direct Burial Steel Tape Armoured Multi Loose Tube Cable

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

8 x 12 Fibres Per Tube Offering up to 96 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For direct burial applications, the single sheathed

product range offers up to 96 fibres in a compact

and relatively flexible construction. The product

range consists of multiple 2.50mm loose tubes

containing up to 12 fibres and solid fillers where

required, stranded around a rigid glass non

metallic central strength member. A layer of

water blocking tape provides interstitial water

blocking and a layer of steel tape armour provides

additional crush resistance.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MSU only)

14.70 258/210 3000 147 22084-96 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Product Part Numbering - MSU 04 - Universal

84 Fibre

96 Fibre

62.5/125

HF 062 S84 W STA LU

HF 062 S96 W STA LU

50/125

HF 050 S84 W STA LU

HF 050 S96 W STA LU

OM3

HF OM3 S84 W STA LU

HF OM3 S96 W STA LU

OM4

HF OM4 S84 W STA LU

HF OM4 S96 W STA LU

OS1/OS2

HF 008 S84 W STA LU

HF 008 S96 W STA LU

Tested in accordance with IEC 60794-1-2 unless stated

Product Part Numbering - MSE 04 - External

62.5/125

HF 062 S96 W STA NM

HF 062 S84 W STA NM

96 Fibre

84 Fibre

50/125

HF 050 S96 W STA NM

HF 050 S84 W STA NM

OM3

HF OM3 S96 W STA NM

HF OM3 S84 W STA NM

OM4

HF OM4 S96 W STA NM

HF OM4 S84 W STA NM

OS1/OS2

HF 008 S96 W STA NM

HF 008 S84 W STA NM

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 108: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

107

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical Cables - Universal MSU 03 and External MSE 03Direct Burial Steel Tape Armoured Multi Loose Tube cable

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

12 x 12 Fibres Per Tube Offering up to 144 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For direct burial applications, the single sheathed

product range offers up to 144 fibres in a compact

and relatively flexible construction.

The product range consists of multiple 2.50mm

loose tubes containing up to 12 fibres and solid

fillers where required, stranded around a sheathed

rigid glass non metallic central strength member.

A layer of water blocking tape provides interstitial

water blocking and a layer of corrugated steel

tape armour gives additional crush resistance.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

LSHF or PE Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Central Strength Member Sheath

Rigid Glass Central Strength Member

Water Blocking Tape

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MSU only)

18.20 327/313 2000 182 273108 - 144 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

144 Fibre

132 Fibre

120 Fibre

108 Fibre

HF 062 S144 W STA LU

HF 062 S132 W STA LU

HF 062 S120 W STA LU

HF 062 S108 W STA LU

62.5/125 50/125

HF 050 S144 W STA LU

HF 050 S132 W STA LU

HF 050 S120 W STA LU

HF 050 S108 W STA LU

OM3

HF OM3 S144 W STA LU

HF OM3 S132 W STA LU

HF OM3 S120 W STA LU

HF OM3 S108 W STA LU

OM4

HF OM4 S144 W STA LU

HF OM4 S132 W STA LU

HF OM4 S120 W STA LU

HF OM4 S108 W STA LU

Product Part Numbering - MSU 03 - Universal

144 Fibre

132 Fibre

120 Fibre

108 Fibre

HF 062 S144 W STA NM

HF 062 S132 W STA NM

HF 062 S120 W STA NM

HF 062 S108 W STA NM

62.5/125 50/125

HF 050 S144 W STA NM

HF 050 S132 W STA NM

HF 050 S120 W STA NM

HF 050 S108 W STA NM

OM3

HF OM3 S144 W STA NM

HF OM3 S132 W STA NM

HF OM3 S120 W STA NM

HF OM3 S108 W STA NM

OM4

HF OM4 S144 W STA NM

HF OM4 S132 W STA NM

HF OM4 S120 W STA NM

HF OM4 S108 W STA NM

Product Part Numbering - MSE 03 - External

Tested in accordance with IEC 60794-1-2 unless stated

HF 008 144 W STA LU

HF 008 S132 W STA LU

HF 008 S120 W STA LU

HF 008 S108 W STA LU

OS1/OS2

HF 008 144 W STA NM

HF 008 S132 W STA NM

HF 008 S120 W STA NM

HF 008 S108 W STA NM

OS1/OS2

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 109: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

108

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical Cables - Universal MSU 05 and External MSE 05Direct Burial Steel Tape Armoured Multi Loose Tube cable

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

18 x 12 Fibres Per Tube Offering up to 216 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For direct burial applications, the single sheathed

product range offers up to 216 fibres in a compact

and relatively flexible construction. The product

range consists of multiple 2.50mm loose tubes

containing up to 12 fibres and solid fillers where

required, stranded around a sheathed rigid glass

non metallic central strength member. A layer

of water blocking tape provides interstitial water

blocking and a layer of corrugated steel tape

armour gives additional crush resistance.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

LSHF or PE Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

19.00 352/303 2000 190 285156-216 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

192 Fibre

180 Fibre

168 Fibre

156 Fibre

Product Part Numbering - MSU 05 - Universal

216 Fibre

204 Fibre

62.5/125

HF 062 S192 W STA LU

HF 062 S180 W STA LU

HF 062 S168 W STA LU

HF 062 S156 W STA LU

HF 062 S216 W STA LU

HF 062 S204 W STA LU

50/125

HF 050 S192 W STA LU

HF 050 S180 W STA LU

HF 050 S168 W STA LU

HF 050 S156 W STA LU

HF 050 S216 W STA LU

HF 050 S204 W STA LU

OM3

HF OM3 S192 W STA LU

HF OM3 S180 W STA LU

HF OM3 S168 W STA LU

HF OM3 S156 W STA LU

HF OM3 S216 W STA LU

HF OM3 S204 W STA LU

OM4

HF OM4 S192 W STA LU

HF OM4 S180 W STA LU

HF OM4 S168 W STA LU

HF OM4 S156 W STA LU

HF OM4 S216 W STA LU

HF OM4 S204 W STA LU

OS1/OS2

HF 008 S192 W STA LU

HF 008 S180 W STA LU

HF 008 S168 W STA LU

HF 008 S156 W STA LU

HF 008 S216 W STA LU

HF 008 S204 W STA LU

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MSU only)

Product Data

192 Fibre

180 Fibre

168 Fibre

156 Fibre

216 Fibre

204 Fibre

Product Part Numbering - MSE 05 - External

HF 062 S192 W STA NM

HF 062 S180 W STA NM

HF 062 S168 W STA NM

HF 062 S156 W STA NM

62.5/125

HF 062 S216 W STA NM

HF 062 S204 W STA NM

50/125

HF 050 S192 W STA NM

HF 050 S180 W STA NM

HF 050 S168 W STA NM

HF 050 S156 W STA NM

HF 050 S216 W STA NM

HF 050 S204 W STA NM

OM3

HF OM3 S192 W STA NM

HF OM3 S180 W STA NM

HF OM3 S168 W STA NM

HF OM3 S156 W STA NM

HF OM3 S216 W STA NM

HF OM3 S204 W STA NM

OM4

HF OM4 S192 W STA NM

HF OM4 S180 W STA NM

HF OM4 S168 W STA NM

HF OM4 S156 W STA NM

HF OM4 S216 W STA NM

HF OM4 S204 W STA NM

OS1/OS2

HF 008 S192 W STA NM

HF 008 S180 W STA NM

HF 008 S168 W STA NM

HF 008 S156 W STA NM

HF 008 S216 W STA NM

HF 008 S204 W STA NM

Tested in accordance with IEC 60794-1-2 unless stated

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 110: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

109

O62 050 OM3 OM4 BM3 BM4 008 108 208

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MSU2 only)

Brand-Rex Optical Cables - Universal MTU 01 and External MTE 01Burial Steel Tape Armoured Multi Loose Tube Cable

Product Part Numbering - MTU 01 - Universal

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

6 x 4 Fibres Per Tube Offering up to 24 Fibres

2.10mm Gel filled Loose Tube

PRODUCT DESCRIPTION

For applications where a higher tensile load

is required versus that offered by unitube

constructions, the universal product range offers

a compact low fibre count direct burial grade

cable. The product range consists of multiple

2.10mm loose tubes containing up to 4 fibres

and solid fillers where required, stranded around

a rigid glass non metallic central strength member.

A layer of water blocking tape provides interstitial

water blocking and the LSHF or PE inner sheath

and a layer of corrugated steel tape armour

provide additional crush resistance.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

LSHF or PE Outer Sheath

LSHF or PE Inner Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

Product Part Numbering - MTE 01 - External

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

24 Fibre

20 Fibre

16 Fibre

12 Fibre

8 Fibre

4 Fibre

HF 062 S24 W L STA LU 4FT

HF 062 S20 W L STA LU 4FT

HF 062 S16 W L STA LU 4FT

HF 062 S12 W L STA LU 4FT

HF 062 S8 W L STA LU 4FT

HF 062 S4 W L STA LU 4FT

62.5/125 50/125

HF 050 S24 W L STA LU 4FT

HF 050 S20 W L STA LU 4FT

HF 050 S16 W L STA LU 4FT

HF 050 S12 W L STA LU 4FT

HF 050 S8 W L STA LU 4FT

HF 050 S4 W L STA LU 4FT

OM3

HF OM3 S24 W L STA LU 4FT

HF OM3 S20 W L STA LU 4FT

HF OM3 S16 W L STA LU 4FT

HF OM3 S12 W L STA LU 4FT

HF OM3 S8 W L STA LU 4FT

HF OM3 S4 W L STA LU 4FT

OM4

HF OM4 S24 W L STA LU 4FT

HF OM4 S20 W L STA LU 4FT

HF OM4 S16 W L STA LU 4FT

HF OM4 S12 W L STA LU 4FT

HF OM4 S8 W L STA LU 4FT

HF OM4 S4 W L STA LU 4FT

OS1/OS2

HF 008 S24 W L STA LU 4FT

HF 008 S20 W L STA LU 4FT

HF 008 S16 W L STA LU 4FT

HF 008 S12 W L STA LU 4FT

HF 008 S8 W L STA LU 4FT

HF 008 S4 W L STA LU 4FT

14.10 247/198 1500 145 2154 - 24 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

62.5/125

HF 062 S16 W NM STA NM 4FT

HF 062 S12 W NM STA NM 4FT

HF 062 S24 W NM STA NM 4FT

HF 062 S20 W NM STA NM 4FT

HF 062 S8 W NM STA NM 4FT

HF 062 S4 W NM STA NM 4FT

24 Fibre

20 Fibre

16 Fibre

12 Fibre

8 Fibre

4 Fibre

50/125

HF 050 S24 W NM STA NM 4FT

HF 050 S20 W NM STA NM 4FT

HF 050 S16 W NM STA NM 4FT

HF 050 S12 W NM STA NM 4FT

HF 050 S8 W NM STA NM 4FT

HF 050 S4 W NM STA NM 4FT

OM3

HF OM3 S24 W NM STA NM 4FT

HF OM3 S20 W NM STA NM 4FT

HF OM3 S16 W NM STA NM 4FT

HF OM3 S12 W NM STA NM 4FT

HF OM3 S8 W NM STA NM 4FT

HF OM3 S4 W NM STA NM 4FT

OM4

HF OM4 S24 W NM STA NM 4FT

HF OM4 S20 W NM STA NM 4FT

HF OM4 S16 W NM STA NM 4FT

HF OM4 S12 W NM STA NM 4FT

HF OM4 S8 W NM STA NM 4FT

HF OM4 S4 W NM STA NM 4FT

OS1/OS2

HF 008 S24 W NM STA NM 4FT

HF 008 S20 W NM STA NM 4FT

HF 008 S16 W NM STA NM 4FT

HF 008 S12 W NM STA NM 4FT

HF 008 S8 W NM STA NM 4FT

HF 008 S4 W NM STA NM 4FT

Tested in accordance with IEC 60794-1-2 unless stated

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 111: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

110

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical Cables - Universal MTU 02 and External MTE 02Universal Direct Burial Steel Tape Armoured Multi Loose Tube Cable

Product Part Numbering - MTU 02 - Universal

Product Part Numbering - MTE 02 - External

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

15.30 284/231 2000 153 23012 - 72 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

72 Fibre

60 Fibre

48 Fibre

36 Fibre

24 Fibre

12 Fibre

HF 062 S72 W L STA LU

HF 062 S60 W L STA LU

HF 062 S48 W L STA LU

HF 062 S36 W L STA LU

HF 062 S24 W L STA LU

HF 062 S12 W L STA LU

62.5/125 50/125

HF 050 S72 W L STA LU

HF 050 S60 W L STA LU

HF 050 S48 W L STA LU

HF 050 S36 W L STA LU

HF 050 S24 W L STA LU

HF 050 S12 W L STA LU

OM3

HF OM3 S72 W L STA LU

HF OM3 S60 W L STA LU

HF OM3 S48 W L STA LU

HF OM3 S36 W L STA LU

HF OM3 S24 W L STA LU

HF OM3 S12 W L STA LU

OM4

HF OM4 S72 W L STA LU

HF OM4 S60 W L STA LU

HF OM4 S48 W L STA LU

HF OM4 S36 W L STA LU

HF OM4 S24 W L STA LU

HF OM4 S12 W L STA LU

OS1/OS2

HF 008 S72 W L STA LU

HF 008 S60 W L STA LU

HF 008 S48 W L STA LU

HF 008 S36 W L STA LU

HF 008 S24 W L STA LU

HF 008 S12 W L STA LU

72 Fibre

60 Fibre

48 Fibre

36 Fibre

24 Fibre

12 Fibre

HF 062 S72 WNM STA NM

HF 062 S60 WNM STA NM

HF 062 S48 WNM STA NM

HF 062 S36 WNM STA NM

HF 062 S24 WNM STA NM

HF 062 S12 WNM STA NM

62.5/125 50/125

HF 050 S72 WNM STA NM

HF 050 S60 WNM STA NM

HF 050 S48 WNM STA NM

HF 050 S36 WNM STA NM

HF 050 S24 WNM STA NM

HF 050 S12 WNM STA NM

OM3

HF OM3 S72 WNM STA NM

HF OM3 S60 WNM STA NM

HF OM3 S48 WNM STA NM

HF OM3 S36 WNM STA NM

HF OM3 S24 WNM STA NM

HF OM3 S12 WNM STA NM

OM4

HF OM4 S72 WNM STA NM

HF OM4 S60 WNM STA NM

HF OM4 S48 WNM STA NM

HF OM4 S36 WNM STA NM

HF OM4 S24 WNM STA NM

HF OM4 S12 WNM STA NM

OS1/OS2

HF 008 S72 WNM STA NM

HF 008 S60 WNM STA NM

HF 008 S48 WNM STA NM

HF 008 S36 WNM STA NM

HF 008 S24 WNM STA NM

HF 008 S12 WNM STA NM

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MSU2 only)

Tested in accordance with IEC 60794-1-2 unless stated

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

6 x 12 Fibres Per Tube Offering up to 72 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For direct burial applications, the twin sheathed

product range offers up to 72 fibres in a compact

and relatively flexible construction. The product

range consists of multiple 2.50mm loose tubes

containing up to 12 fibres and solid fillers where

required, stranded around a rigid glass non

metallic central strength member. A layer of water

blocking tape provides interstitial water blocking

and a layer of corrugated steel tape armour gives

additional crush resistance.

LSHF or PE Outer Sheath

LSHF or PE Inner Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 112: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

111

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical Cables - Universal MTU 04 and External MTE 04Universal Direct Burial Steel Tape Armoured Multi Loose Tube Cable

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

8 x 12 Fibres Per Tube Offeringup to 96 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For direct burial applications, the twin sheathed

product range offers up to 96 fibres in a compact

and relatively flexible construction. The product

range consists of multiple 2.50mm loose tubes

containing up to 12 fibres and solid fillers where

required, stranded around a rigid glass non

metallic central strength member. A layer of water

blocking tape provides interstitial water blocking

and a layer of corrugated steel tape armour gives

additional crush resistance.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

LSHF or PE Outer Sheath

LSHF or PE Inner Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

16.7 330/260 3000 167 25084 - 96 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MTU only)

Product Part Numbering - MTU 04 - Universal

Product Part Numbering - MTE 04 - External

Tested in accordance with IEC 60794-1-2 unless stated

62.5/125

HF 062 S96 WNM STA NM

HF 062 S84 WNM STA NM

96 Fibre

84 Fibre

50/125

HF 050 S96 WNM STA NM

HF 050 S84 WNM STA NM

OM3

HF OM3 S96 WNM STA NM

HF OM3 S84 WNM STA NM

OM4

HF OM4 S96 WNM STA NM

HF OM4 S84 WNM STA NM

OS1/OS2

HF 008 S96 WNM STA NM

HF 008 S84 WNM STA NM

96 Fibre

84 Fibre

62.5/125

HF 062 S84 W L STA LU

HF 062 S96 W L STA LU

50/125

HF 050 S84 W L STA LU

HF 050 S96 W L STA LU

OM3

HF OM3 S84 W L STA LU

HF OM3 S96 W L STA LU

OM4

HF OM4 S84 W L STA LU

HF OM4 S96 W L STA LU

OS1/OS2

HF 008 S84 W L STA LU

HF 008 S96 W L STA LU

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 113: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

112

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Optical Cables - Universal MTU 03 and External MTE 03Direct Burial Steel Tape Armoured Multi Loose Tube cable

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

12 x 12 Fibres Per Tube Offering up to 144 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For direct burial applications, the twin

sheathed product range offers up to 144 fibres

in a compact and relatively flexible construction.

The range consists of multiple 2.50mm loose

tubes containing up to 12 fibres and solid fillers

where required, stranded around a sheathed rigid

glass non metallic central strength member.

A layer of water blocking tape provides interstitial

water blocking and a layer of corrugated steel

tape armour gives additional crush resistance.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

LSHF or PE Outer Sheath

LSHF or PE Inner Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Central Strength Member Sheath

Rigid Glass Central Strength Member

Water Blocking Tape

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

Tested in accordance with IEC 60794-1-2 unless stated

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MSU only)

144 Fibre

132 Fibre

120 Fibre

108 Fibre

HF 062 S144 W L STA LU

HF 062 S132 W L STA LU

HF 062 S120 W L STA LU

HF 062 S108 W L STA LU

62.5/125 50/125

HF 050 S144 W L STA LU

HF 050 S132 W L STA LU

HF 050 S120 W L STA LU

HF 050 S108 W L STA LU

OS1/OS2

HF 008 144 W L STA LU

HF 008 S132 W L STA LU

HF 008 S120 W L STA LU

HF 008 S108 W L STA LU

Product Part Numbering - MTU 03 - Universal

OM3

HF OM3 S144 W L STA LU

HF OM3 S132 W L STA LU

HF OM3 S108 W L STA LU

HF OM3 S120 W L STA LU

OM4

HF OM4 S144 W L STA LU

HF OM4 S132 W L STA LU

HF OM4 S108 W L STA LU

HF OM4 S120 W L STA LU

Product Data

20.00 445/355 2000 200 300108 - 144 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

144 Fibre

132 Fibre

120 Fibre

108 Fibre

HF 062 S144 W NM STA NM

HF 062 S132 W NM STA NM

HF 062 S120 W NM STA NM

HF 062 S108 W NM STA NM

62.5/125 50/125

HF 050 S144 W NM STA NM

HF 050 S132 W NM STA NM

HF 050 S120 W NM STA NM

HF 050 S108 W NM STA NM

OM3

HF OM3 S144 W NM STA NM

HF OM3 S132 W NM STA NM

HF OM3 S120 W NM STA NM

HF OM3 S108 W NM STA NM

OM4

HF OM4 S144 W NM STA NM

HF OM4 S132 W NM STA NM

HF OM4 S120 W NM STA NM

HF OM4 S108 W NM STA NM

OS1/OS2

HF 008 144 W NM STA NM

HF 008 S132 W NM STA NM

HF 008 S120 W NM STA NM

HF 008 S108 W NM STA NM

Product Part Numbering - MTE 03 - External

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 114: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

113

O62 050 OM3 OM4 BM3 BM4 008 108 208

Outer LSHF or PE Sheath

Inner LSHF or PE Sheath

Gel Filled

Loose Tube

Corrugated Steel

Tape Armour

Individual Coloured Fibres

Rigid Glass Central Strength Member

Water Blocking Tape

PRODUCT PERFORMANCE

Crush (N):

4000

Impact (Nm):

10

Torsion (turns / m):

5

Fire:

IEC 60332-1

(MSU only)

Brand-Rex Optical Cables - Universal MTU 05 and External MTE 05Direct Burial Steel Tape Armoured Multi Loose Tube cable

Corrugated Steel Tape Armour

Rigid Glass Central Strength Member

Choice of Universal or External Sheath

18 x 12 Fibres Per Tube Offering up to 216 Fibres

2.50mm Gel Filled Loose Tube

PRODUCT DESCRIPTION

For direct burial applications, the twin sheathed

product range offers up to 216 fibres in a compact

and relatively flexible construction. The range

consists of multiple 2.50mm loose tubes

containing up to 12 fibres and solid fillers where

required, stranded around a sheathed rigid glass

non metallic central strength member. A layer of

water blocking tape provides interstitial water

blocking and a layer of corrugated steel tape

armour gives additional crush resistance.

Temp - Operation:

-40°c to +70°c

Temp - Storage:

-40°c to +70°c

Temp - Installation:

-10°c to +70°c

Water Penetration:

<3m @ 24h

S T E E L TA P E A R M O U R E D M U LT I L O O S E T U B E C A B L E

Product Data

20.90 451/370 2000 209 314156-216 Fibre

Diameter

mm

Weight

(U)/(E)

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Product Part Numbering - MTU 05 - Universal

Tested in accordance with IEC 60794-1-2 unless stated

192 Fibre

180 Fibre

168 Fibre

156 Fibre

216 Fibre

204 Fibre

62.5/125

HF 062 S192 W L STA LU

HF 062 S180 W L STA LU

HF 062 S168 W L STA LU

HF 062 S156 W L STA LU

HF 062 S216 W L STA LU

HF 062 S204 W L STA LU

50/125

HF 050 S192 W L STA LU

HF 050 S180 W L STA LU

HF 050 S168 W L STA LU

HF 050 S156 W L STA LU

HF 050 S216 W L STA LU

HF 050 S204 W L STA LU

OM3

HF OM3 S192 W L STA LU

HF OM3 S180 W L STA LU

HF OM3 S156 W L STA LU

HF OM3 S168 W L STA LU

HF OM3 S216 W L STA LU

HF OM3 S204 W L STA LU

OM4

HF OM4 S192 W L STA LU

HF OM4 S180 W L STA LU

HF OM4 S156 W L STA LU

HF OM4 S168 W L STA LU

HF OM4 S216 W L STA LU

HF OM4 S204 W L STA LU

OS1/OS2

HF 008 192 W L STA LU

HF 008 S180 W L STA LU

HF 008 S168 W L STA LU

HF 008 S156 W L STA LU

HF 008 S216 W L STA LU

HF 008 S204 W L STA LU

192 Fibre

180 Fibre

168 Fibre

156 Fibre

Product Part Numbering - MTE 05 - External

HF 062 S192 W NM STA NM

HF 062 S132 W NM STA NM

HF 062 S168 W NM STA NM

HF 062 S156 W NM STA NM

62.5/125

HF 062 S216 W NM STA NM

HF 062 S204 W NM STA NM

216 Fibre

204 Fibre

50/125

HF 050 S192 W NM STA NM

HF 050 S132 W NM STA NM

HF 050 S168 W NM STA NM

HF 050 S156 W NM STA NM

HF 050 S216 W NM STA NM

HF 050 S204 W NM STA NM

OM3

HF OM3 S192 W NM STA NM

HF OM3 S132 W NM STA NM

HF OM3 S168 W NM STA NM

HF OM3 S156 W NM STA NM

HF OM3 S216 W NM STA NM

HF OM3 S204 W NM STA NM

OM4

HF OM4 S192 W NM STA NM

HF OM4 S132 W NM STA NM

HF OM4 S168 W NM STA NM

HF OM4 S156 W NM STA NM

HF OM4 S216 W NM STA NM

HF OM4 S204 W NM STA NM

OS1/OS2

HF 008 192 W NM STA NM

HF 008 S168 W NM STA NM

HF 008 S168 W NM STA NM

HF 008 S156 W NM STA NM

HF 008 S216 W NM STA NM

HF 008 S204 W NM STA NM

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 115: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

114

Brand-Rex is pleased to offer FibrePlus cables

for specialist applications. Two FibrePlus

cables are described in this section. The UFS

Fire Survival cable is used in areas where

critical data transmission must continue

when the building structure in which it is

installed is on fire. For this reason its use in

large public buildings such as datacentres,

airports, railway stations, stadia and

onshore/ offshore industrial structures

is becoming increasingly common.

The use of the cable in building

management, fire and security systems

means that these vital systems will remain

functional in the event of a real life incident

which requires an emergency evacuation.

As a company that is driven by our

customers needs, Brand-Rex will always

be happy to offer specialist products to

order based on your own specification.

This includes complex requirements

ranging from cables for extreme

environments to simple requirements

such as composite cables, custom sheath

colours or printing. Please enquire about

our customised cable service.

S P E C I A L E N V I R O N M E N T C A B L E S

Page 116: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

115

O62 050 OM3 OM4 BM3 BM4 008 108 208

F I R E S U R V I V A L C A B L E

Independent 3rd party tested (BRE)

Unitube design offering up to 24 fibres

Layer of fire retardant tape

Twin low smoke halogen-free sheaths

4.00mm gel filled loose tube

PRODUCT DESCRIPTION

In today’s business environment the secure

backup of business critical systems in the

event of an emergency is a pre-requisite.

The UFS 01 Fire Survival cable is used in areas

where critical data transmission must continue

when the building or structure in which it is

installed is on fire. For this reason its use in

large public buildings such as datacentres,

airports, railway stations, stadia and onshore/

offshore industrial structures is becoming

increasingly common. The use of the cable in

building management, fire and security systems

means that these vital systems will remain

functional in the event of a real life incident

which requires an emergency evacuation.

PRODUCT PERFORMANCE

Crush (N):

2500

Impact (Nm):

30

Torsion (turns / m):

1

Acid Gas Emissions:

Pass

Smoke Index:

Pass

Temp - Operation:

-40°C to +70°C

Temp - Storage:

-40°C to +70°C

Temp - Installation:

-10°C to +70°C

Fire:

(IEC 60331-25)

Pass (90 mins @ 750°C)

(BSEN50200 -2000)

Pass PH120, BS 8434-2 Pass,

IEC 60332-3-24 Pass,

IEC 60332-1-2 Pass

Brand-Rex Optical Cables - Universal UFS 01Unitube Fire Survival Cable

LSHF Outer Sheath

Corrugated Steel Tape Armour

LSHF Inner Sheath

Water Blocking Glass Yarns

Fire Retardant Tape

Gel Filled Loose Tube

Individual Coloured Fibres

13.00 210 700 130 1954-24 Fibre

Diameter

mm

Weight

kg / km

Max Tensile

Load

N

Min Static

Bend

mm

Min Dynamic

Bend

mm

Product Data

24 Fibre

16 Fibre

12 Fibre

8 Fibre

4 Fibre

Product Part Numbering

Tested in accordance with IEC 60794-1-2 unless stated

62.5/125

EF062UNI24LSTALUFS RD

EF062UNI16LSTALUFS RD

EF062UNI12LSTALUFS RD

EF062UNI8LSTALUFS RD

EF062UNI4LSTALUFS RD

50/125

EF050UNI24LSTALUFS RD

EF050UNI16LSTALUFS RD

EF050UNI12LSTALUFS RD

EF050UNI8LSTALUFS RD

EF050UNI4LSTALUFS RD

OM3

EFOM3UNI24LSTALUFS RD

EFOM3UNI16LSTALUFS RD

EFOM3UNI12LSTALUFS RD

EFOM3UNI8LSTALUFS RD

EFOM3UNI4LSTALUFS RD

OM4

EFOM4UNI24LSTALUFS RD

EFOM4UNI16LSTALUFS RD

EFOM4UNI12LSTALUFS RD

EFOM4UNI8LSTALUFS RD

EFOM4UNI4LSTALUFS RD

OS1/OS2

EF008UNI24LSTALUFS RD

EF008UNI16LSTALUFS RD

EF008UNI12LSTALUFS RD

EF008UNI8LSTALUFS RD

EF008UNI4LSTALUFS RD

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 117: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

116

FibrePlus is a comprehensive range of

premium products including Single Mode

and Multi Mode Pigtails and Patch cords

using ST, SC, FC and Small Form Factor MT-RJ

and LC Connectors and Adaptors.

All connectorised assembly types are

available as either Multi Mode; to connect

OM1, OM2, OM3 and OM4 cables and Single

Mode to connect OS1 and OS2 cables.

All are manufactured to comply with the

international standards ISO/IEC 11801,

EN50173-1 and ANSI/TIA/ETA 568C.

For rack management the Fibre Plus Optical

Patch Panel, Cable Management Plates

and Modules offer a flexible cost effective

solution with the ability to cater for growth

and churn.

Available as an empty panel, suitable for all

major connector types the product is able

to manage up to 96 Fibres in 1U using Small

Form Factor connectors.

The sliding shelf design along with other

added features enable quick and easy

reconfiguration, expansion making future

upgrades and expansion both quicker and

easier. Full Blolite support is part of the

flexible future proofing designed into

this product.

Pre-Connectorised Cable Assemblies,

Wall outlets, complete the range providing

end to end, in-building and campus

cabling solutions.

O P T I C A L C O M P O N E N T S

Page 118: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

117

Manufactured to comply with: ISO/IEC 11801,EN50173 -1, ANSI TIA/EIA 568.C

All major connector types

Colour coded for identification

Duplex patchcords feature ‘Crossover’

OM1 Grade Cable

PRODUCT DESCRIPTION

For use in permanent connections between

transmission equipment and patch panels or

interconnect / cross connect between panels.

Patch cords are pre-constructed with connectors.

These include small form factors such as LC and

MT-RJ as well as SC, FC and ST. Based on 2.80mm

sub units (1.9mm SFF) these ruggedised cables

are sheathed with LSHF material making them

suitable for internal use.

O P T I C A L S Y S T E M S

Optical Performance (IEC 60874-1 Method 7)

Product Part Numbering

Brand-Rex Optical Components - Patch Cords62.5/12.5 Multi Mode Optical Patch Cords

Temp - Operation:

-10°c to +70°c

Temp - Storage:

-25°c to +80°c

Temp - Installation:

0°c to +70°c

Sheath Colour:

Orange

(Others available on request)

CABLE PROPERTIES

Crush (N):

1500

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1-2

0.5

0.2 0.2

20.0 20.0

0.5

ST SC

Insertion Loss Max dB

Return Loss Min dB

Insertion Loss Typical dB 0.2 0.4 0.2

20.0 20.0 20.0

0.5 0.75 0.5

FC-PC MT-RJ LC

1.00m 2.00m

FC - FC Duplex

LC - SC Duplex

LC - ST Duplex

LC - LC Duplex

MT-RJ - MT-RJ Duplex

MT-RJ - SC Duplex

MT-RJ - ST Duplex

MTRJ - LC Duplex

SC - SC Duplex

SC - ST Duplex

ST - ST Duplex

HOPFC062010FC291

HOPLC062010SC293

HOPLC062010ST293

HOPLC062010LC293

HOPMJ062010MJ292

HOPMJ062010SC292

HOPMJ062010ST292

HOPMJ062010LC292

HOPSC062010SC291

HOPSC062010ST291

HOPST062010ST291

HOPFC062020FC291

HOPLC062020SC293

HOPLC062020ST293

HOPLC062020LC293

HOPMJ062020MJ292

HOPMJ062020SC292

HOPMJ062020ST292

HOPMJ062020LC292

HOPSC062020SC291

HOPSC062020ST291

HOPST062020ST291

HOPFC062030FC291

HOPLC062030SC293

HOPLC062030ST293

HOPLC062030LC293

HOPMJ062030MJ292

HOPMJ062030SC292

HOPMJ062030ST292

HOPMJ062030LC292

HOPSC062030SC291

HOPSC062030ST291

HOPST062030ST291

HOPFC062050FC291

HOPLC062050SC293

HOPLC062050ST293

HOPLC062050LC293

HOPMJ062050MJ292

HOPMJ062050SC292

HOPMJ062050ST292

HOPMJ062050LC292

HOPSC062050SC291

HOPSC062050ST291

HOPST062050ST291

3.00m 5.00m

Page 119: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

118

Brand-Rex Optical Components - Patch Cords50/125 Multi Mode Optical Patch Cords Manufactured to comply with:

ISO/IEC 11801,EN50173 -1, ANSI TIA/EIA 568.C

All major connector types

Colour coded for identification

Duplex patch cords feature ‘Crossover’

OM2 Grade Cable

PRODUCT DESCRIPTION

For use in permanent connections between

transmission equipment and patch panels or

interconnect / cross connect between panels.

Patch cords are pre-constructed with connectors.

These include small form factors such as LC and

MT-RJ as well as SC, FC and ST. Based on 2.80mm

sub units (1.9mm SFF) these ruggedised cables

are sheathed with LSHF material making them

suitable for internal use.Product Part Numbering

Optical Performance (IEC 60874-1 Method 7)

O P T I C A L S Y S T E M S

Temp - Operation:

-10°c to +70°c

Temp - Storage:

-25°c to +80°c

Temp - Installation:

0°c to +70°c

Sheath Colour:

Orange

(Others available on request)

CABLE PROPERTIES

Crush (N):

1500

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1-2

0.5

0.2 0.2 0.2 0.4 0.2

20.0 20.0 20.0 20.0 20.0

0.5 0.5 0.75 0.5

ST SC FC-PC MT-RJ LC

Insertion Loss Max dB

Return Loss Min dB

Insertion Loss Typical dB

1.00m 2.00m

FC - FC Duplex

LC - SC Duplex

LC - ST Duplex

LC - LC Duplex

MT-RJ - MT-RJ Duplex

MT-RJ - SC Duplex

MT-RJ - ST Duplex

MT-RJ - LC Duplex

SC - SC Duplex

SC - ST Duplex

ST - ST Duplex

HOPFC050010FC291

HOPLC050010SC293

HOPLC050010ST293

HOPLC050010LC293

HOPMJ050010MJ292

HOPMJ050010SC292

HOPMJ050010ST292

HOPMJ050010LC292

HOPSC050010SC291

HOPSC050010ST291

HOPST050010ST291

HOPFC050020FC291

HOPLC050020SC293

HOPLC050020ST293

HOPLC050020LC293

HOPMJ050020MJ292

HOPMJ050020SC292

HOPMJ050020ST292

HOPMJ050020LC292

HOPSC050020SC291

HOPSC050020ST291

HOPST050020ST291

HOPFC050030FC291

HOPLC050030SC293

HOPLC050030ST293

HOPLC050030LC293

HOPMJ050030MJ292

HOPMJ050030SC292

HOPMJ050030ST292

HOPMJ050030LC292

HOPSC050030SC291

HOPSC050030ST291

HOPST050030ST291

HOPFC050050FC291

HOPLC050050SC293

HOPLC050050ST293

HOPLC050050LC293

HOPMJ050050MJ292

HOPMJ050050SC292

HOPMJ050050ST292

HOPMJ050050LC292

HOPSC050050SC291

HOPSC050050ST291

HOPST050050ST291

3.00m 5.00m

Page 120: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

119

Manufactured to comply with:

ISO/IEC 11801,

EN50173 -1,

ANSI TIA/EIA 568B

All major connector types

Colour coded for identification

Duplex patch cords feature ‘Crossover’

OM3 Grade Cable

PRODUCT DESCRIPTION

For use in permanent connections between

transmission equipment and patch panels or

interconnect / cross connect between panels.

Patch cords are pre-constructed with connectors.

These include small form factors such as LC and

MT-RJ as well as SC, FC and ST. Based on 2.80mm

sub units (1.9mm SFF) these ruggedised cables

are sheathed with LSHF material making them

suitable for internal use.

0.5

0.2 0.2 0.2 0.4 0.2

20.0 20.0 20.0 20.0 20.0

0.5 0.5 0.75 0.5

ST SC FC-PC MT-RJ LC

Optical Performance (IEC 60874-1 Method 7)

Insertion Loss Max dB

Return Loss Min dB

Insertion Loss Typical dB

Brand-Rex Optical Components - Patch Cords50/125 OM3 Multi Mode Optical Patch Cords

Product Part Numbering

O P T I C A L S Y S T E M S

Temp - Operation:

-10°c to +70°c

Temp - Storage:

-25°c to +80°c

Temp - Installation:

0°c to +70°c

Sheath Colour:

Aqua

(Others available on request)

CABLE PROPERTIES

Crush (N):

1500

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1-2

1.00m 2.00m

FC - FC Duplex

LC - SC Duplex

LC - ST Duplex

LC - LC Duplex

MT-RJ - MT-RJ Duplex

MT-RJ - SC Duplex

MT-RJ - ST Duplex

MT-RJ - LC Duplex

SC - SC Duplex

SC - ST Duplex

ST - ST Duplex

HOPFCOM3010FC251

HOPLCOM3010SC253

HOPLCOM3010ST253

HOPLCOM3010LC253

HOPMJOM3010MJ252

HOPMJOM3010SC252

HOPMJOM3010ST252

HOPMJOM3010LC252

HOPSCOM3010SC251

HOPSCOM3010ST251

HOPSTOM3010ST251

HOPFCOM3020FC251

HOPLCOM3020SC253

HOPLCOM3020ST253

HOPLCOM3020LC253

HOPMJOM3020MJ252

HOPMJOM3020SC252

HOPMJOM3020ST252

HOPMJOM3020LC252

HOPSCOM3020SC251

HOPSCOM3020ST251

HOPSTOM3020ST251

HOPFCOM3030FC251

HOPLCOM3030SC253

HOPLCOM3030ST253

HOPLCOM3030LC253

HOPMJOM3030MJ252

HOPMJOM3030SC252

HOPMJOM3030ST252

HOPMJOM3030LC252

HOPSCOM3030SC251

HOPSCOM3030ST251

HOPSTOM3030ST251

HOPFCOM3050FC251

HOPLCOM3050SC253

HOPLCOM3050ST253

HOPLCOM3050LC253

HOPMJOM3050MJ252

HOPMJOM3050SC252

HOPMJOM3050ST252

HOPMJOM3050LC252

HOPSCOM3050SC251

HOPSCOM3050ST251

HOPSTOM3050ST251

3.00m 5.00m

Page 121: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

120

Manufactured to comply with:

ISO/IEC 11801,

EN50173 -1,

ANSI TIA/EIA 568B

All major connector types

Colour coded for identification

Duplex patch cords feature ‘Crossover’

OM4 Grade Cable

PRODUCT DESCRIPTION

For use in permanent connections between

transmission equipment and patch panels or

interconnect / cross connect between panels.

Patch cords are pre-constructed with connectors.

These include small form factors such as LC and

MT-RJ as well as SC, FC and ST. Based on 2.80mm

sub units (1.9mm SFF) these ruggedised cables

are sheathed with LSHF material making them

suitable for internal use.

0.5

0.2 0.2 0.2 0.4 0.2

20.0 20.0 20.0 20.0 20.0

0.5 0.5 0.75 0.5

ST SC FC-PC MT-RJ LC

Optical Performance (IEC 60874-1 Method 7)

Insertion Loss Max dB

Return Loss Min dB

Insertion Loss Typical dB

Brand-Rex Optical Components - Patch Cords50/125 OM4 Multi Mode Optical Patch Cords

Product Part Numbering

O P T I C A L S Y S T E M S

Temp - Operation:

-10°c to +70°c

Temp - Storage:

-25°c to +80°c

Temp - Installation:

0°c to +70°c

Sheath Colour:

Heather Violet

(Others available on request)

CABLE PROPERTIES

Crush (N):

1500

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1-2

1.00m 2.00m

FC - FC Duplex

LC - SC Duplex

LC - ST Duplex

LC - LC Duplex

MT-RJ - MT-RJ Duplex

MT-RJ - SC Duplex

MT-RJ - ST Duplex

MT-RJ - LC Duplex

SC - SC Duplex

SC - ST Duplex

ST - ST Duplex

HOPFCOM4010FC271

HOPLCOM4010SC273

HOPLCOM4010ST273

HOPLCOM4010LC273

HOPMJOM4010MJ272

HOPMJOM4010SC272

HOPMJOM4010ST272

HOPMJOM4010LC272

HOPSCOM4010SC271

HOPSCOM4010ST271

HOPSTOM4010ST271

HOPFCOM4020FC271

HOPLCOM4020SC273

HOPLCOM4020ST273

HOPLCOM4020LC273

HOPMJOM4020MJ272

HOPMJOM4020SC272

HOPMJOM4020ST272

HOPMJOM4020LC272

HOPSCOM4020SC271

HOPSCOM4020ST271

HOPSTOM4020ST271

HOPFCOM4030FC271

HOPLCOM4030SC273

HOPLCOM4030ST273

HOPLCOM4030LC273

HOPMJOM4030MJ272

HOPMJOM4030SC272

HOPMJOM4030ST272

HOPMJOM4030LC272

HOPSCOM4030SC271

HOPSCOM4030ST271

HOPSTOM4030ST271

HOPFCOM4050FC271

HOPLCOM4050SC273

HOPLCOM4050ST273

HOPLCOM4050LC273

HOPMJOM4050MJ272

HOPMJOM4050SC272

HOPMJOM4050ST272

HOPMJOM4050LC272

HOPSCOM4050SC271

HOPSCOM4050ST271

HOPSTOM4050ST271

3.00m 5.00m

Page 122: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

121

Brand-Rex Optical Components - Patch CordsSingle Mode Optical Patch Cords Manufactured to comply with:

ISO/IEC 11801,EN50173 -1, ANSI TIA/EIA 568B

All major connector types

Colour coded for identification

Duplex patch cords feature ‘Crossover’

OS1/OS2 Grade Cable

PRODUCT DESCRIPTION

For use in permanent connections between

transmission equipment and patch panels or

interconnect / cross connect between panels.

Patch cords are pre-constructed with connectors.

These include small form factors such as LC, SC, FC

and ST. Based on 2.80mm sub units (1.9mm SFF)

these ruggedised cables are sheathed with LSHF

material making them suitable for internal use.

0.3

0.2 0.2 0.2 0.4 0.1

45.0 45.0 45.0 26.0 45.0

0.3 0.3 0.75 0.3

ST SC FC-PC MT-RJ LC

Optical Performance (IEC 60874-1 Method 7)

Insertion Loss Max dB

Return Loss Min dB

Insertion Loss Typical dB

Product Part Numbering Temp - Operation:

-10°c to +70°c

Temp - Storage:

-25°c to +80°c

Temp - Installation:

0°c to +70°c

Sheath Colour:

Yellow

CABLE PROPERTIES

Crush (N):

1500

Impact (Nm):

5

Torsion (turns / m):

5

Fire:

IEC 60332-1-2

1.00m 2.00m

FC - FC Duplex

LC - SC Duplex

LC - ST Duplex

LC - LC Duplex

SC - SC Duplex

SC - ST Duplex

ST - ST Duplex

HOPFC008010FC201

HOPLC008010SC203

HOPLC008010ST203

HOPLC008010LC203

HOPSC008010SC201

HOPSC008010ST201

HOPST008010ST201

HOPFC008020FC201

HOPLC008020SC203

HOPLC008020ST203

HOPLC008020LC203

HOPSC008020SC201

HOPSC008020ST201

HOPST008020ST201

HOPFC008030FC201

HOPLC008030SC203

HOPLC008030ST203

HOPLC008030LC203

HOPSC008030SC201

HOPSC008030ST201

HOPST008030ST201

HOPFC008050FC201

HOPLC008050SC203

HOPLC008050ST203

HOPLC008050LC203

HOPSC008050SC201

HOPSC008050ST201

HOPST008050ST201

O P T I C A L S Y S T E M S

3.00m 5.00m

Page 123: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

122

O62 050 OM3 OM4 BM3 BM4 008 108 208

OM4

Red

Red/Yellow (MT-RJ)

O P T I C A L P I G TA I L S

Single Mode and Multi Mode Optical Pigtails

Manufactured to comply with: ISO/IEC 11801,EN50173 -1, ANSI TIA/EIA 568B

Based on Tight Buffered Core

900μm and 600μm

All major connector types

All major fibre types

Colour coded for identification

PRODUCT DESCRIPTION

For use in permanent connections between patch

panels and incoming cables / single blown fibres.

Pigtails are pre-constructed with connectors.

Connector options include small form factors

such as LC as well as SC, FC and ST. Based on

900μm tight buffered cores (600μm SFF) and

suitable for internal use only inside suitable Fibre

Management Systems.

Product Colour Coding

OM1 OM2 OM3

Blue

Blue/Orange (MT-RJ)

Green

Green/Brown (MT-RJ)

Grey

Grey/Orange (MT-RJ)

Optical Performance (IEC 60874-1 Method 7)

Insertion Loss Max dB

Insertion Loss Typical dB

0.5

0.2

20.0

ST

45.0

0.2

20.0

0.5

SC

45.0

0.2

20.0

0.5

FC-PC

45.0

0.4

20.0

0.75

MT-RJ

-

0.2/0.1

20.0

0.5/0.3

LC

MM/SM

45.0

Multi Mode Return Loss Min dB

Single Mode Return Loss Min dB

Temp - Operation:

-10°c to +70°c

Temp - Storage:

-25°c to +80°c

Temp - Installation:

0°c to +70°c

CABLE PROPERTIES

Crush (N):

800

Impact (Nm):

0.2

Min Bend (mm):

50

Product Part Numbering

FC - 1 metre

SC - 1 metre

ST - 1 metre

LC - 1 metre

MT-RJ - 1 metre

HOTFC062001

HOTSC062001

HOTST062001

HOTLSC062001

HOTMJ062501

HOTFC050001

HOTSC050001

HOTST050001

HOTLSC050001

HOTMJ050501

HOTFCOM3001

HOTSCOM3001

HOTSTOM3001

HOTLSCOM3001

HOTMJOM3501

HOTFC008001

HOTSC008001

HOTST008001

HOTLSC008001

-

OM1 OM2 OM3 OS1/OS2OM4

HOTFCOM4001

HOTSCOM4001

HOTSTOM4001

HOTLSCOM4001

HOTMJOM4501

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Page 124: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

123

Brand-Rex Optical Components - FibrePlus Patch PanelsFibrePlus - Unloaded Panels & Panel Options

Enhanced sliding tray for easy access

complete with quick release fastenings

Adjustable mounting brackets aids

installation within shallow enclosures

Minimum depth 237mm

Rear of panel offers a range of apertures

to accommodate a variety of gland

configurations

Front panel configuration options:

24 fibre using ST,SC, FC-PC, LC or MT-RJ

48 fibre using Duplex SC, Duplex LC or MT-RJ

96 fibre using Quad LC

management and glands

customised fibre management and additional

anchoring points for incoming cables or ducts

a port identification strip

PRODUCT DESCRIPTION

The FibrePlus 1U fibre 19” Optic Patch Panels

have been designed to optimise both the internal

fibre management but also to add greater

fibre density. Constructed from mild steel with

a powder coated paint finish the panels are

available in Black or Grey. The Patch Panels offers

a flexible and highly versatile solution for optical

splicing and patching. The panel’s shallow depth

allows it to be installed within the majority of

standard racks and wall mounted enclosures.

The integrated design features ensure that

even once installed panels can be readily

re-configured to accommodate the changing

needs of today’s high speed networks.

O P T I C A L S Y S T E M S

Description

FPCC1SXXX24ST2

FPCC1SXXX24DC2

FPCC1SXXX48DC2

FPCC1SXXX48SC2

FPCFMKIT001

30-0301-5

30-0506-09

BPEST101-100

BPESC101-100

BPESC301-100

30-4800-09

ML-25

HOTLCOM3001

BHCL4SM001

BHCL4MM001

Notes: *Panels are also avaialble in grey, to order please replace the ‘2’ in the catalogue number

with ‘8’. i.e. FPCC1SXSM04ST2 becomes FPCC1SXSM04ST8

Product Part Numbering

Standard panel rear gland hole configuration

Unloaded Optical for up to 24 ST or FC adaptors - Black

Unloaded Optical for up to 12 SC Duplex or LC Quad adaptors - Black

Unloaded Optical for up to 24 SC Duplex or LC Quad adaptors - Black

Unloaded Optical for up to 24 SC Simplex, MT-RJ & LC Duplex adaptors - Black

Fibre management kit including loops and 24 way splice bridge

Adaptor collar for 3mm Straight connector

5mm Bloduct bulkhead connector

ST/FC Blanking Plugs (Black) - Pack 100

SC Simplex Blanking Plug (also suitable for LC & MT -RJ) (Black) - Pack 100

SC Duplex Blanking Plug (also suitable for LC Quad) (Black) - Pack 100

25mm Manifold Gland

25mm Lock Nut

1m Simplex 900 um OM3 LC Pigtail

LC Singlemode Quad adaptor (SC Duplex Type Footprint) – 24 Included in FPCC 1SXSM96LC2

LC Multimode Quad adaptor (SC Duplex Type Footprint) - 24 Included in FPCC 1SXMM96LC2

Page 125: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

124

483

ST Single Mode

ST Multi Mode

FC Single Mode

SC Duplex - Single Mode

SC Duplex - Multi Mode

SC Simplex Single Mode

SC Simplex Multi Mode

MT-RJ Duplex

LC Duplex Single Mode

LC Duplex Multi Mode

LC Quad Single Mode

LC Quad Multi Mode

FPCC1SXSM04ST2

FPCC1SXMM04ST2

FPCC1SXSM04FC2

FPCC1SXSM08DC2

FPCC1SXMM08DC2

FPCC1SXSM04SC2

FPCC1SXMM04SC2

FPCC1SXXM08MJ2

FPCC1SXSM08LC2

FPCC1SXMM08LC2

-

-

4 Adaptor

FPCC1SXSM06ST2

FPCC1SXMM06ST2

FPCC1SXSM06FC2

FPCC1SXSM12DC2

FPCC1SXMM12DC2

FPCC1SXSM06SC2

FPCC1SXMM06SC2

FPCC1SXXM12MJ2

FPCC1SXSM12LC2

FPCC1SXMM12LC2

-

-

6 Adaptor

FPCC1SXSM08ST2

FPCC1SXMM08ST2

FPCC1SXSM08FC2

FPCC1SXSM16DC2

FPCC1SXMM16DC2

FPCC1SXSM08SC2

FPCC1SXMM08SC2

FPCC1SXXM16MJ2

FPCC1SXSM16LC2

FPCC1SXMM16LC2

-

-

8 Adaptor

FPCC1SXSM12ST2

FPCC1SXMM12ST2

FPCC1SXSM12FC2

FPCC1SXSM24DC2

FPCC1SXMM24DC2

FPCC1SXSM12SC2

FPCC1SXMM12SC2

FPCC1SXXM24MJ2

FPCC1SXSM24LC2

FPCC1SXMM24LC2

-

-

12 Adaptor

FPCC1SXSM16ST2

FPCC1SXMM16ST2

FPCC1SXSM16FC2

FPCC1SXSM32DC2

FPCC1SXMM32DC2

FPCC1SXSM16SC2

FPCC1SXMM16SC2

FPCC1SXXM32MJ2

FPCC1SXSM32LC2

FPCC1SXMM32LC2

-

-

16 Adaptor

FPCC1SXSM24ST2

FPCC1SXMM24ST2

FPCC1SXSM24FC2

FPCC1SXSM48DC2

FPCC1SXMM48DC2

FPCC1SXSM24SC2

FPCC1SXMM24SC2

FPCC1SXXM48MJ2

FPCC1SXSM48LC2

FPCC1SXMM48LC2

FPCC1SXSM96LC2

FPCC1SXMM96LC2

24 Adaptor

Brand-Rex Optical Components - FibrePlus Patch PanelsFibrePlus - Part Loaded Patch Panels

FibrePlus Panels are pre loaded

with Fibre Optic adaptors

Front Panel for up to 24 fibre FC, ST, SC

12 or 24 way DC, 48 fibre LC, MT-RJ,

96 fibre LC quad

Minimum depth 237mm

Front Panel includes a port identification strip

Suitable for Blolite

PRODUCT DESCRIPTION

The FibrePlus 19” 1U fibre Optic Patch Panels

have been designed to optimise both the internal

fibre management but also to add greater

fibre density. Constructed from mild steel with

a powder coated paint finish the panels are

available in Black or Grey. The Patch Panels offers

a flexible and highly versatile solution for optical

splicing and patching. The panel’s shallow depth

allows it to be installed within the majority of

standard racks and wall mounted enclosures.

The integrated design features ensure that even

once installed panels can be readily re-configured

to accommodate the changing needs of today’s

high speed networks.

O P T I C A L S Y S T E M S

Description

Product Part Numbering

Standard panel rear gland hole configuration

Page 126: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

125

482

238

44 max

O P T I C A L S Y S T E M S

Brand-Rex Optical Components - FibrePlus Patch PanelHigh Density Fibre Management Panel

Built for the High Density Fibre Cabinet

17” and 19” Frame compatible

48 LC ports 1U - using unique ½U trays

Innovative design using angled adapters for

ease of fibre management

Fully integrated fibre & splice management,

no need for multiple splice cassettes

Unique pivoting, sliding & hinged tray

35mm minimum bend radius maintained

throughout fibre management system

PRODUCT DESCRIPTION

The High Density Fibre Management Panel

offers the ultimate solution for management

of fibre in datacentres and telecoms rooms.

The panel combines a robust metal frame with

precision injection moulded plastic to deliver

a flexible and secure construction while still

offering fully integrated and flexible fibre

management. The 1U 48 LC port patch panel

facilitates patch cord routing directly into the

rack vertical side management, thus increasing

rack density and easing undue stresses on

the cords. It is designed to pivot and hinge

providing the control and security of a fixed

panel but also allowing for increased access

and usability.

PRODUCT CHARACTERISTICS

Applications

cable management products.

Installation

Inclusion of pigtails is also an option.

Packaging

Material Data

powder coated mild steel - RAL 9005 Black.

High Density Fibre Management Panel, 48 LC Ports, 1U Dual cassette, part loaded with

12 x Quad LC Multi-mode adaptors & glands - Black

High Density Fibre Management Panel, 48 LC Ports, 1U Dual cassette, part loaded with

12 x Quad LC Single-mode adaptors & glands - Black

Description

FPCPC1XMM48LC2

FPCPC1XSM48LC2

Part Number

Product Part Numbering

For corresponding High Density Fibre

Cabling Cabinet please see page 15

Page 127: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

126

Brand-Rex Optical Components - Connectors /AdaptorsSC Optical Connectors

Connector Adaptor

Product Part Numbering

SC Simplex Connector:

SC multimode and single mode connector kits comprise of a one piece

SC body with precision ceramic ferrule, crimp, sleeve, colour coded outer shroud,

2 x colour coded 3mm strain relief boots and a 0.9mm boot.

Compliant with BS EN 61754-4

Typical Insertion Loss: MM - 0.2dB, SM - 0.15dB

Minimum Return Loss: SM 45dB

SC Duplex Connector:

SC Duplex connector kits comprise of 2 simplex connectors mounted in a two

piece polymer clip and 2 x colour coded 3mm strain relief boots.

Compliant with BS EN 61754-4

Typical Insertion Loss: MM - 0.2dB, SM - 0.15dB

Minimum Return Loss: SM 45dB

SC Simplex Adaptor:

SC Adaptors comprise of a polymer outer body and inner assembly

fitted with a precision alignment sleeve. Multimode with metal

sleeve. Single mode with Ceramic Sleeve.

Compliant with IEC 60874-15

Max. Insertion Loss: MM - 0.3dB, SM - 0.1dB

SC Duplex Adaptor:

SC Duplex adaptors comprise of a polymer outer body and an inner

assembly fitted with a precision alignment sleeve.

Multimode with metal sleeve. Single mode with Ceramic Sleeve.

Compliant with IEC 60875-14

Max. Insertion Loss: MM - 0.3dB, SM - 0.1dB

BHCSCMM001

BHCSCSM001

BHCDCMM001

BHCDCSM001

SC - MultiMode (Beige)

SC - Single Mode (Blue)

SC Duplex - Multi Mode (Beige)

SC Duplex - Single Mode (Blue)

FOCSCEPMM001

FOCSCEPSM001

FOCDCEPMM001

FOCDCEPSM001

O P T I C A L S Y S T E M S

Page 128: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

127

ST Adaptor:

a precision alignment sleeve. They are both standard and double

‘D’ hole compatible. Multimode with metal sleeve. Single mode

with ceramic sleeve.

Compliant with BE EN 61754-2

Max. Insertion Loss: MM - 0.3dB, SM - 0.1dB

FC Adaptor:

FC adaptors comprise of a nickel plated brass body that is fitted

with a precision alignment sleeve. They are standard single and

double 'D' hole compatible.

Compliant with BS EN 61754-13

Max. Insertion Loss: SM - 0.1dB

ST Connector:

a precision ceramic ferrule, crimp sleeve, 2 x colour coded 3mm strain

reliefs and a 0.9mm boot.

Compliant with BS EN 61754-2

Strain Relief Colour Code: MM - Red, Black

SM - Yellow, Black

Typical Insertion Loss: MM - 0.2dB, SM - 0.15dB

Minimum Return Loss: SM 45dB

FC-PC Connector:

FC-PC single mode connector kits comprise of a nickel plated brass

body with a precision ceramic ferrule, stepped crimp sleeve,

2 x colour coded strain relief boots and a 0.9mm boot.

Compliant with BS EN 61754-13

Strain Relief Colour Code: SM - Yellow, Black

Typical Insertion Loss: SM - 0.15dB

Minimum Return Loss: SM 45dB

O P T I C A L S Y S T E M S

Brand-Rex Optical Components - Connectors /AdaptorsST, FC Optical Connectors

FOCSTEPMM001

FOCSTEPSM001

FOCFCEPSM001

BHCSTMM001

BHCSTSM001

BHCFCSM001

ST - Multi Mode

ST Single Mode

FC-PC Single Mode

Connector Adaptor

Product Part Numbering

Page 129: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

128

MT-RJ Duplex Adaptor:

MT-RJ adaptors have a polymer outer body which has the outer

Compliant with BS EN 61754-18

LC Connector:

LC multimode and single mode connector kits comprise of a precision

ferrule, crimp sleeve, colour coded outer shroud, 2 x colour coded

2.0mm strain reliefs (..001) or a 0.9mm (..002) boot.

Compliant with BS EN 61754-20

Typical Insertion Loss: MM - <0.2dB, SM - <0.15dB

Minimum Return Loss: MM 20dB, SM 45dB

Available as either simplex or duplex variants.

LC Duplex Adaptor:

LC adaptors (BHCLCXM001) comprise of a polymer body with

a precision alignment sleeves. They have the outer dimensions

of a simplex SC style adaptor.

Compliant with BS EN 61754-20

LC Quad Adaptor:

LC adaptors (BHCL4XM001) comprise of a polymer body with

precision alignment sleeves. They have the outer dimensions

of a duplex SC style adaptor.

Compliant with BS EN 61754-20

PRODUCT DESCRIPTION

The range of Brand-Rex SFF (Small Form Factor) connectivity solutions are reliable and robust, quality products. SFF connectors are duplex fibre

connectors which have a footprint similar to RJ-45's, offering the system integrator / installer an improved patching density, saving valuable rack

space. The products can be used at the panel or in the work area supporting both backbone fibre and fibre to the desk solutions. Brand-Rex offers

a choice of leading, de-facto, SFF connectors, the MT-RJ and the LC.

O P T I C A L S Y S T E M S

Brand-Rex Optical Components - Connectors /AdaptorsST, FC Optical Connectors

FOCLCEPMM001

FOCLCEPSM001

FOCLSEPMM001

FOCLSEPSM001

FOCLSEPMM002

FOCLSEPSM002

-

-

-

BHCLCMM001

BHCLCSM001

-

-

-

-

BHCL4MM001

BHCL4SM001

BHCMJXX001

LC Multi Mode (Duplex) (Beige)

LC Single Mode (Duplex) (Blue)

LC Multi Mode (Simplex) (Beige)

LC Single Mode (Simplex) (Blue)

LC Multi Mode (Simplex Pigtail) (Beige)

LC Single Mode (Simplex Pigtail) (Blue)

LC Multi Mode (Quad) Beige

LC Single Mode (Quad) (Blue)

MT RJ adaptor

Connector Adaptor

Product Part Numbering

Page 130: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

129

45

5050

50

37.7

24.3

36

22

Brand-Rex Optical Components Faceplate ModulesFibrePlus – 45mm x 45mm and 50mm x 50mm

Faceplate Modules

PRODUCT DESCRIPTION

The Brand-Rex range of 45 x 45 Fibre faceplate

modules is designed for use in installation

poles, wall trunking and back boxes.

Configurations are available for Euro style 45

x 45mm faceplates and UK style 50 x 50mm

versions offering a versatile solution.

Quad and Duplex LC option

Duplex SC option

cover

identification

Description Catalogue Number Quantity per Pack

45 x 45 mm Fibre Faceplate Module LC Duplex Multi Mode FPCANGLCMM3 10

45 x 45 mm Fibre Faceplate Module LC Duplex Single Mode FPCANGLCSM3 10

45 x 45 mm Fibre Faceplate Module LC Quad Multi Mode FPCANGL4MM3 10

45 x 45 mm Fibre Faceplate Module LC Quad Single Mode FPCANGL4SM3 10

45 x 45 mm Fibre Faceplate Module SC Duplex Multi Mode FPCANGDCMM3 10

45 x 45 mm Fibre Faceplate Module SC Duplex Single Mode FPCANGDCSM3 10

50 x 50 mm Fibre Faceplate Module LC Duplex Multi Mode FPCANGLCMM3UK 10

50 x 50 mm Fibre Faceplate Module LC Duplex Single Mode FPCANGLCSM3UK 10

50 x 50 mm Fibre Faceplate Module LC Quad Multi Mode FPCANGL4MM3UK 10

50 x 50 mm Fibre Faceplate Module LC Quad Single Mode FPCANGL4SM3UK 10

50 x 50 mm Fibre Faceplate Module SC Duplex Multi Mode FPCANGDCMM3UK 10

50 x 50 mm Fibre Faceplate Module SC Duplex Single Mode FPCANGDCSM3UK 10

86 x 147 mm Double Gang Modular Faceplate MMCWDOUNI031 1

44 mm Deep Double Gang UK Back Box MMCDGBB44002 1

86 x 86mm Single Gang Modular Faceplate MMCWDOUNI030 1

44mm Deep Back Box MMCSGBB44001 1

O P T I C A L S Y S T E M S

Page 131: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

130

O P T I C A L S Y S T E M S

Manufactured to comply with:

ISO/IEC 11801 Amd 1 and 2

EN50173-1

ANSI TIA/EIA 568-C

PRODUCT DESCRIPTION

The Secure Lock system comprises of

secure patch cord, blank adaptor plug

and extraction tool.

The Secure LC patch cord prevents unauthorised

port access or changes as it can only be removed

using a unique keyed extraction tool, making

it ideal for creating a secure area within Data

centres and IT networks.

The Duplex LC patch cords will plug into any

industry compliant Duplex and Quad adapters or

active interfaces

The locking plug closes off ports, restricting

access and offering dust protection. When fitted,

the plug can only be removed with the correct

the tool.

The keyed extraction tool unlocks and releases

the connectors from ports. Keys are available for

custom applications and can be customised to

only release the same coloured LC connector or

blank adapter plug.

secure and tamper proof connection

adapters and SFP LC transceiver interfaces

SM, MM cables and 900μm fibre tails

unauthorised change or removal

and application

CABLE PROPERTIES

Crush (N): 3.5 N/mm

Impact (Nm): 0.74 Nm

Torsion (turns/m): 10

Fire: IEC 60332 and UL1666

Temp - Operation: -40°c to +70°c

Temp - Storage: -40°c to +70°c

Temp installation: -10°c to +70°c

Brand-Rex Optical ComponentsSecure LC Patch Cord System

Page 132: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

131

O P T I C A L S Y S T E M S

Product Part Numbering

* Part is also available for custom applications with Key colour matched to the connector colour

Brand-Rex Optical ComponentsSecure LC Patch Cord System

OLP-LC-xxx-yyy-LC-zzzOptical Locking

Patch Cord

Connector type End 1 xxx = Fibre Type Standard yyy = Length Connector type End 2 zzz = Connector Colour

LC = LC 008 = SM 010 = 1.0m LC = LC 001 = Red

0M3 = 0M3 020 = 2.0m 002 = Black

0M4 = 0M4 030 = 3.0m 003 = White

050 = 5.0m 005 = Green

Other lengths available

upon request

006 = Yellow

008 = Grey

009 = Orange

051 = Aqua

Other colours available

upon request

Description Length Catalogue Number

LC Duplex Singlemode Secure Patch cord 1m

LC Duplex Singlemode Secure Patch cord 2m

LC Duplex Singlemode Secure Patch cord 3m

LC Duplex Singlemode Secure Patch cord 5m

LC Duplex OM3 Multimode Secure Patch cord 1m

LC Duplex OM3 Multimode Secure Patch cord 2m

LC Duplex OM3 Multimode Secure Patch cord 3m

LC Duplex OM3 Multimode Secure Patch cord 5m

LC Duplex OM4 Multimode Secure Patch cord 1m

LC Duplex OM4 Multimode Secure Patch cord 2m

LC Duplex OM4 Multimode Secure Patch cord 3m

LC Duplex OM4 Multimode Secure Patch cord 5m

Secure Patch Cord Blank Adaptor Plug n/a OLCLCBLK-xxx

Secure Patch Cord Master Extraction Key (Violet)* n/a OLCLCTOOL-015

Page 133: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

132

O P T I C A L C O M P O N E N T S

PRODUCT DESCRIPTION

KeyQuick® Mechanical Splice is an innovative,

quick and easy to use mechanical splice. The full

field termination solution includes mechanical

splice and splice holders as well as universal

connectors and is designed to offer installers

a fast, accurate and user friendly splicing process.

The unique transparent body and visual

fault locater offer an installation time of only

30 seconds, allowing 2.5 times more fibre

connections to be made when compared with

the traditional fusion splice method.

The KeyQuick® mechanical splice offers

industry leading reliability and its unique

design gives fantastic performance results,

typically under 0.1dB.

splice verification

PRODUCT CHARACTERISTICS

Applications: LAN, WAN, Data

centres, FTTx, Metro

Networks, Telecoms,

Network Monitoring

IEC11801 compliant

ITU-T G.671

MECHANICAL SPECIFICATIONS

Assembly Time: 30 secs

(after prep time)

Mean Insertion Loss: 0.1dB

Return Loss (dB): -60dB typical

Pull Strength (N): Universal 0.5fkg

(900μm),

Operating Temp (⁰C): -40 - +75

Materials: Engineering plastics

& Index matching gel

Dimensions (mm) 38 x 3.8 x 6.5

(L x W x H)

Brand-Rex Optical ComponentsKeyQuick® Mechanical Splice

Before connection

Insert the fibre Push to the end Press the button

KeyQuick® Mechanical Splice 250μm, 900μm

KeyQuick® Mechanical Splice Holder

Clear

Black

100

50

FPCMS001

FPCMSH06

Description Catalogue NumberColourQty

Splice HolderAfter connection

Page 134: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

133

Before connection

Strip and cleave Insert and press Fit the boot

After connection

PRODUCT DESCRIPTION

KeyQuick® Field Installable KQ10 Connectors

offer an innovative solution for onsite connector

terminations. The SC connectors are ideal for

offering an easy, fast, accurate and user friendly

connector splicing process.

The unique transparent body and visual fault

locater offer a quick installation time of only 30

seconds, allowing 2.5 times more connections

to be made when compared with the traditional

fusion splice method. The connectors are very

easy to assemble and can be used without any

specialised training.

The KeyQuick® connectors offer industry leading

reliability and their unique design gives fantastic

performance results, typically 0.2dB.

confirmation

PRODUCT CHARACTERISTICS

Applications: LAN, WAN, Data

centres, FTTx, Metro

Networks, Telecoms,

Network Monitoring

IEC11801 compliant

ITU-T G.671

MECHANICAL SPECIFICATIONS

Assembly Time: 30 secs

(after prep time)

Mean Insertion Loss: 0.2dB

Return Loss (dB): -60dB typical

Pull Strength (N): Universal 0.5fkg

(900μm),

Operating Temp (⁰C): -40 - +75

Materials: Engineering plastics

& Index matching gel

Dimensions (mm) 38 x 3.8 x 6.5

(L x W x H)

Brand-Rex Optical ComponentsKeyQuick® KQ10 Field Installable Connectors

KeyQuick® SC APC Singlemode Connector -

Universal G652D

KeyQuick® SC UPC Singlemode Connector -

Universal G652D

KeyQuick® SC UPC Multimode Connector -

Universal 62.5/125

KeyQuick® SC UPC Multimode Connector -

Universal 50/125 OM3

KeyQuick® SC UPC Multimode Connector -

Universal 50/125 OM4

Green with black boot

Blue with black boot

Beige with black boot

Clear Blue with black boot

Aqua with black boot

25

25

25

25

25

FOCACFT008001

FOCUCFT008001

FOCUCFT062001

FOCUCFTOM3001

FOCUCFTOM4001

Description Catalogue NumberColourQty

O P T I C A L C O M P O N E N T S

Page 135: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

134

Customer requirements in the

ever-advancing communications market

continues to grow, stretching scarce

bandwidth resources and truly testing

the performance of today’s networks.

In choosing cabling system solutions,

whether for small, medium or large

multi site locations, server farms or

co-location datacentres, network planners

have some serious issues to consider.

Among these is the decision as to which

type and mix of fibre to install to allow for

network expansion and upgrades has been

a dilemma for many years.

In the past, industry practice has been

to install ‘dark fibre’ to meet future demands,

however, this strategy is by no means

risk-free as unterminated, untested fibres

may not be fit for purpose when the time

comes to light the fibres in the future.

Fortunately there is a simple and cost

effective solution - Brand-Rex Air Blown

Fibre Systems offer solutions Internal and

External applications with their market

leading Blolite and MicroBlo. The use of

Air Blown Fibre Systems gives complete

freedom from risk by pre-installing a ducting

route and then blowing in the fibre element

(and paying for it) only when required.

The Blolite system was one of the first

Air Blown Fibre systems, it is also regarded

as the 'industry standard' Air Blown Fibre

System. The Blolite system is very versatile

with backbone and / or fibre to the desk

links and can even allow for long distance

link of up to 1km. Blolite is easily installed,

by using compressed air, there is no

disruption to the workplace, Blolite fibres

are simply terminated and are compatible

with all standard optical connectors.

failure rate since the first installations in 1988

- truly an 'insurance policy' for high speed

networks. It is no surprise that major users

such as Manchester Airport, IBM, Ericsson,

ABN Amro, the British MoD, Aerospatiale,

advantage of the system.

A I R B L O W N F I B R E S Y S T E M S

Page 136: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

135

Microduct size = 3/2.1mm

Part Number

Description Diameter (mm)

Weight (kg/km)

Tensile Load (N)*

Min Bend

Radius Installed (mm)**

Min Bend Radius Short Term

(mm)***

BL01IN0321 1w 3/2.1mm (PO)-I 5.0 29 70 75 25

BL04IN0321 4w 3/2.1mm (PO)-I 9.3 67 150 100 50

BL07IN0321 7w 3/2.1mm (PO)-I 11.7 89 400 120 60

BL12IN0321 12w 3/2.1mm (PO)-I 15.2 126 500 200 100

BL19IN0321 19w 3/2.1mm (PO)-I 17.7 165 1000 270 135

Part Number

Description Diameter (mm)

Weight (kg/km)

Tensile Load (N)*

Min Bend

Radius Installed (mm)**

Min Bend Radius Short Term

(mm)***

BL01IN0535 1w 5/3.5mm (LSHF)-I 5.0 15 50 154 25

BL02IN0535 2w 5/3.5mm (LSHF)-I 7.5 x 13.0 100 300 262 40

BL04IN0535 4w 5/3.5mm (LSHF)-I 15.2 157 500 294 128

BL07IN0535 7w 5/3.5mm (LSHF)-I 18.6 203 700 354 180

BL12IN0535 12w 5/3.5mm (LSHF)-I 24.0 280 1150 468 350

BL19IN0535 19w 5/3.5mm (LSHF)-I 29.6 415 1650 554 410

Part Number

Description Diameter (mm)

Weight (kg/km)

Tensile Load (N)*

Min Bend

Radius Installed (mm)**

Min Bend Radius Short Term

(mm)***

BL01IN0806 1w 8/6mm (LSHF)-I 8.0 50 120 214 40

BL02IN0806 2w 8/6mm (LSHF)-I 10.5 x 19.0 173 600 262 80

BL04IN0806 4w 8/6mm (LSHF)-I 23.0 305 1000 440 180

BL07IN0806 7w 8/6mm (LSHF)-I 27.6 384 1500 534 270

BL12IN0806 12w 8/6mm (LSHF)-I 36.0 598 1500 718 360

Microduct size = 5/3.5mm

Microduct size = 8/6mm

Brand-Rex Air Blown Fibre - Blolite Blolite Internal MultiDucts

A I r B L O w N F I B r e S y S t e M S

LSHF Outer Sheath

Polyester tape

MicroDuct

Available with 3mm, 5mm or 8mm MicroDucts

Non Metallic Design

Simple MicroDuct Identification

PRODUCT DESCRIPTION

to facilitate the installation of Blolite single

blown fibres a range of multi-way MicroDucts

into which Blolite fibres, can be blown are

availible. the internal range of these MicroDucts

are constructed with the standard Blolite

MicroDuct surrounded with a layer of polyester

tape and a LSHF out sheath making them suitable

for internal applications.

PRODUCT PERFORMANCE

Fire: IeC 60332-1

temp - Operation: -20°c to +60°c

temp - Storage: -40°c to +80°c

temp - Installation: -10°c to +70°c

Page 137: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

136

Brand-Rex Air Blown Fibre - BloliteBlolite Direct Intall MultiDucts

Available with 5mm or 8mm MicroDucts

Non Metallic Design

MicroDuct Numbered for Identification

PRODUCT DESCRIPTION

To facilitate the installation of Blolite single blown

fibres a range of multi-way MicroDucts into

which Blolite fibres can be blown are available.

The external range of these MultiDucts are

constructed with the standard Blolite MicroDuct

surrounded with a layer of Polyester tape and a

Polyethylene outer sheath making them suitable

for direct install applications.

PRODUCT PERFORMANCE

Temp - Operation: -20°c to +60°c

Temp - Storage: -40°c to +70°c

Temp - Installation: -10°c to +70°c

Tested in accordance with IEC60794-5

unless otherwise stated

Microduct size = 5/3.5mm

Microduct size = 8/6mm

PE Outer Sheath

Polyester Tape

MicroDuct

Part

Number

Description Diameter

(mm)

Weight

(kg/km)

Tensile

Load

(N)*

Min

Bend

Radius

Installed

(mm)**

Min Bend

Radius

Short

Term

(mm)***

BL01DI0535 1w 5/3.5mm (LSHF)-O 7.5 30.8 380 168 40

BL02DI0535 2w 5/3.5mm (LSHF)-O 7.5 x 13.0 85.3 630 268 60

BL04DI0535 4w 5/3.5mm (LSHF)-O 15.2 123.7 900 310 180

BL07DI0535 7w 5/3.5mm (LSHF)-O 18.6 180.4 1250 368 250

BL12DI0535 12w 5/3.5mm (LSHF)-O 24.0 280.9 1800 484 310

BL19DI0535 19w 5/3.5mm (LSHF)-O 29.6 402.3 2600 568 370

Part

Number

Description Diameter

(mm)

Weight

(kg/km)

Tensile

Load

(N)*

Min

Bend

Radius

Installed

(mm)**

Min Bend

Radius

Short

Term

(mm)***

BL01DI0806 1w 8/6mm (LSHF)-O 10.5 57.7 450 228 80

BL02DI0806 2w 8/6mm (LSHF)-O 10.5 x 19.0 151.8 800 262 95

BL04DI0806 4w 8/6mm (LSHF)-O 23.0 225.5 1250 454 280

BL07DI0806 7w 8/6mm (LSHF)-O 27.6 344.8 1750 548 380

BL12DI0806 12w 8/6mm (LSHF)-O 36.0 548.1 2000 732 540

A I R B L O W N F I B R E S Y S T E M S

Page 138: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

137

MicroDuct Size Selection Guidelines - Size vs Fibre CountSingle Blown Fibre Elements

Unique ‘Blowable’ coating

12 Standard Colours

Installation up to 1000m

PRODUCT DESCRIPTION

The Blolite system offers a complete range

of high quality single mode and multimode

optical fibres, with a blowable coating and

fibre is strippable with standard tools and is

compatible with standard connector types.

Blolite fibre is available in twelve standard colours

and is supplied on plastic spools in 2km or 4km

lengths for installation into Blolite 3mm, 5mm

and 8mm MicroDuct by trained and licensed

Blolite installers using the IM2000 blow head.

Outer Buffer Layer

First Buffer Layer

Primary coated optical fibre

A I R B L O W N F I B R E S Y S T E M S

MicroDuct Size Selection Guidelines

3mm

3mm

3mm

3mm

3mm

8mm

8mm

8mm

8mm

8mm

3mm

3mm

3mm

3mm

3mm

8mm

8mm

8mm

8mm

8mm

3mm

3mm

3mm

5mm

5mm

8mm

8mm

8mm

8mm

8mm

5mm

5mm

5mm

5mm

5mm

8mm

8mm

8mm

8mm

8mm

100

200

300

400

500

600

700

800

900

1000

1 Fibre 2 Fibre 4 Fibre 6 Fibre

5mm

5mm

5mm

5mm

5mm

8mm

8mm

8mm

8mm

8mm

8 Fibre

5mm

5mm

5mm

5mm

8mm

-

-

-

-

-

12 FibreBlowing

Distance (Metres)

10-0101-03

10-0101-05

10-0101-06

10-0101-07

10-0101-08

10-0101-09

10-0101-10

10-0101-11

10-0101-12

10-0101-13

10-0101-14

10-0101-15

10-0005-03

10-0005-05

10-0005-06

10-0005-07

10-0005-08

10-0005-09

10-0005-10

10-0005-11

10-0005-12

10-0005-13

10-0005-14

10-0005-15

10-0003-03

10-0003-05

10-0003-06

10-0003-07

10-0003-08

10-0003-09

10-0003-10

10-0003-11

10-0003-12

10-0003-13

10-0003-14

10-0003-15

10-0200-03

10-0200-05

10-0200-06

10-0200-07

10-0200-08

10-0200-09

10-0200-10

10-0200-11

10-0200-12

10-0200-13

10-0200-14

10-0200-15

White

Black

Blue

Orange

Green

Red

Grey

Yellow

Brown

Violet

Pink

Turquoise

62.5/125 50/125 OM3 OS1/OS2

Product Part Numbering

OM4

10-0004-03

10-0004-05

10-0004-06

10-0004-07

10-0004-08

10-0004-09

10-0004-10

10-0004-11

10-0004-12

10-0004-13

10-0004-14

10-0004-15

Page 139: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

138

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Air Blown Fibre – MicroBlo2-12 Fibre Blown Micro Cable

PRODUCT DESCRIPTION

Microduct cabling systems are popular

solutions for building flexibility into a network,

they can be populated when needed and

leave spare capacity for future growth. The

ability to defer initial installation costs is a key

advantage of an air blown cable installation

over traditional cable installations. The new

MicroBlo air blown loose tube microduct

cable is available with fibre counts from 2

to 12 in a 2.5 mm diameter package. The

cable has been specifically designed and

developed for improved installation efficiency

in pre-installed 5 / 3.5 mm microducts using

existing air blown installation techniques.

PRODUCT PERFORMANCE

Crush (N): 250

Temp - Operational: -20°C to +60°C

Temp - Storage: -40°C to +70°C

Temp - Installation: -10°C to +40°C

Impact Resistance: 1J

Torsion: 1 Turn per 1m

Water Penetration: < 3 m @ 24 h

Product Data

2 – 12 fibre

Thermoplastic sheath

Gel filled Loose Tube

Individual Coloured Fibres

502.5 755

2 fibre

4 fibre

6 fibre

8 fibre

12 fibre

Fibre count

HF062BMC2WNM3

HF062BMC4WNM3

HF062BMC6WNM3

HF062BMC8WNM3

HF062BMC12WNM3

62.5/125

HF050BMC2WNM3

HF050BMC4WNM3

HF050BMC6WNM3

HF050BMC8WNM3

HF050BMC12WNM3

50/125

HFOM3BMC2WNM3

HFOM3BMC4WNM3

HFOM3BMC6WNM3

HFOM3BMC8WNM3

HFOM3BMC12WNM3

HFOM4BMC2WNM3

HFOM4BMC4WNM3

HFOM4BMC6WNM3

HFOM4BMC8WNM3

HFOM4BMC12WNM3

0M3 0M4

HF008BMC2WNM3

HF008BMC4WNM3

HF008BMC6WNM3

HF008BMC8WNM3

HF008BMC12WNM3

OS1/OS2

A I R B L O W N F I B R E S Y S T E M S

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Product Part Numbering

Diameter

mm

Weight

kg / km

Max Tensile

Load

N

Min Dynamic

Bend

mm

Page 140: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

139

O62 050 OM3 OM4 BM3 BM4 008 108 208

PE Sheath

Gel Filled

Loose Tube

Individual Coloured Fibres

Rigid Glass Central

Strength Member

PRODUCT DESCRIPTION

Microduct cabling systems are popular

solutions for building flexibility into a network,

they can be populated when needed and

leave spare capacity for future growth.

The ability to defer initial installation costs

is a key advantage of an air blown cable

installation over traditional cable installations.

The new MicroBlo air blown loose tube

microduct cable is available with fibre counts

from 12 to 72 in a 6.0 mm diameter package.

The micro cable is constructed of a non

metallic, resin bonded glass central strength

member and high density polyethylene sheath.

The cable has been specifically designed and

developed for improved installation efficiency

in pre-installed 10/8 mm microducts using

existing air blown installation techniques.

Dry water blocking technology ensures

the cable cores are fully water blocked.

PRODUCT CHARACTERISTICS

Crush: 700N

Maximum Tensile Load: 450N

Minimum Bend Radius: 124mm

Weight: 25 kg/km

Temp - Operation: -15°C to +60°C

Temp - Storage: -30°C to +70°C

Temp - Installation: -10°C to +40°C

Water Penetration: <3m @ 24h

Fibre count 62.5/125 50/125 OS1/OS2

12 fibres HF062BMC12WNM6 HF050BMC12WNM6 HFD08BMC12WNM6

24 fibres HF062BMC24WNM6 HF050BMC24WNM6 HFD08BMC24WNM6

36 fibres HF062BMC36WNM6 HF050BMC36WNM6 HFD08BMC36WNM6

48 fibres HF062BMC48WNM6 HF050BMC48WNM6 HFD08BMC48WNM6

60 fibres HF062BMC60WNM6 HF050BMC60WNM6 HFD08BMC60WNM6

72 fibres HF062BMC72WNM6 HF050BMC72WNM6 HFD08BMC72WNM6

A I R B L O W N F I B R E S Y S T E M S

Brand-Rex Air Blown Fibre - MicroBlo 12-72 Fibre Blown Micro Cable

6.0 25 450 12412-72Fibre

Diameter

mm

Weight

kg / km

Max Tensile

Load

N

Min Dynamic

Bend

mm

Product Data

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Fibre Selection Codes

Product Part Numbering

Page 141: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

140

O62 050 OM3 OM4 BM3 BM4 008 108 208

Brand-Rex Air Blown Fibre – MicroBloUp to 96 Fibre Micro Cable

A I R B L O W N F I B R E S Y S T E M S

Non-metallic, Resin Bonded Glass

central strength member.

Layer of stranded elements:-

Maximum 12 fibres per gel filled tube,

plus solid fillers as necessary.

Dry water blocked interstices

High Density Polyethylene Sheath

PRODUCT DESCRIPTION

Microduct cabling systems are popular solutions

for building flexibility into a network, they can

be populated when needed and leave spare

capacity for future growth. The ability to defer

initial installation costs is a key advantage of

an air blown cable installation over traditional

cable installations. The new Microblo air blown

loose tube microduct cable is available with fibre

counts of 84 and 96 fibres in a 7.0mm diameter

package. The cable has been specifically

designed and developed for improved

installation efficiency in pre-installed 12 /9.4 mm

microducts using existing air blown installation

techniques. Dry water blocking technology

ensures the cable cores are fully water blocked.

PRODUCT PERFORMANCE

Crush (N): 700

Temp - Operational: -15°C to +60°C

Temp - Storage: -30°C to +70°C

Temp - Installation: -10°C to +60°C

Impact Resistance: 1J

Torsion: 1 Turn per 2m

Water Penetration: < 3 m @ 24 h

Product Data

Up to 96 fibre

Gel filled Loose Tube

Individual Coloured Fibres

Glass Central Strength Member

PE Sheath

1447.0 100038

84 fibre

96 fibres

Fibre count

HF062BMC84WNM8

HF062BMC96WNM8

62.5/125

HF050BMC84WNM8

HF050BMC96WNM8

50/125

HFOM3BMC84WNM8

HFOM3BMC96WNM8

HFOM4BMC84WNM8

HFOM4BMC96WNM8

0M3 0M4

HF008BMC84WNM8

HF008BMC96WNM8

OS1/OS2

Fibre Selection Codes

Use these part number identifiers to select the fibre type you require by replacing the fibre code

in the part number e.g. HFOM3PDC24LU becomes HFBM3PDC24LU.

Product Part Numbering

Diameter

mm

Weight

kg / km

Max Tensile

Load

N

Min Dynamic

Bend

mm

Page 142: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

141

Brand-Rex Air Blown Fibre – MicroBloMicroBlo Direct Install Protected MicroDucts

A I R B L O W N F I B R E S Y S T E M S

5/3.5mm, 10/8mm and

12/10mm Microducts

1, 2, 4, 7, 12, and 19 Multi-ways

HDPE Sheath

Testing to guidelines set in IEC60794-5

PRODUCT DESCRIPTION

Microduct cabling systems are popular

solutions for building flexibility into a network,

they can be populated when needed and

leave spare capacity for future growth.

The ability to defer initial installation costs

is a key advantage of an air blown cable

installation over traditional cable installations.

To facilitate the installation of Microblo

Microcables, a range of Protected Microducts

(multiways) into which Microcables can be

blown are available. The Direct Install range

of Protected Microducts are constructed

with standard individual microducts with

a PE sheathing for installation into existing

duct and sub-ducting infrastructure.

PRODUCT PERFORMANCE

Temp - Operational: -40°C to +70°C

Temp - Storage: -40°C to +70°C

Temp - Installation: -10°C to +50°C

HDPE Sheath

Product Data

1W 5/3.5mm

2W 5/3.5mm

4W 5/3.5mm

7W 5/3.5mm

12W 5/3.5mm

19W 5/3.5mm

MB01DI0535

MB02DI0535

MB04DI0535

MB07DI0535

MB12DI0535

MB19DI0535

Part Number

Microduct size = 5/3.5mm Outer diameter/Bore

Description Diameter

(mm)*

Weight

(kg/km)

Installed

(mm)

Installation Tensile

Force (N) (Max)

Min Bend

Radius Installed

(mm)**

Min Bend

Radius Short

Term (mm)***

5

11.5

13.6

16.5

21.5

26.5

9.5

36

60

96

160

230

135

270

540

945

1620

2565

50

115

136

165

21.5

265

75

172.5

204

247.5

322.5

397.5

1W 10/8mm

2W 10/8mm

4W 10/8mm

7W 10/8mm

12W 10/8mm

MB01DI1008

MB02DI1008

MB04DI1008

MB07DI1008

MB12DI1008

Part Number

Microduct size = 10/8mm Outer diameter/Bore

Description Diameter

(mm)*

Weight

(kg/km)

Installed

(mm)

Installation Tensile

Force (N) (Max)

Min Bend

Radius Installed

(mm)**

Min Bend

Radius Short

Term (mm)***

10

21.5

25.6

31.5

41.5

27

84

160

280

414

380

760

1520

2660

4560

100

215

256

315

415

150

322.5

384

472.5

622.5

1W 12/10mm

2W 12/10mm

4W 12/10mm

7W 12/10mm

MB01DI1210

MB02DI1210

MB04DI1210

MB07DI1210

Part Number

Microduct size = 12/10mm Outer diameter/Bore

Description Diameter

(mm)*

Weight

(kg/km)

Installed

(mm)

Installation Tensile

Force (N) (Max)

Min Bend

Radius Installed

(mm)**

Min Bend

Radius Short

Term (mm)***

12

25.5

30

37.5

34

110

200

320

465

930

1860

3255

120

255

300

375

180

382.5

450

562.5

Microducts

Page 143: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

142

Brand-Rex Air Blown Fibre – MicroBloMicroBlo Flat Burial Protected MicroDucts

A I R B L O W N F I B R E S Y S T E M S

12.8mm, and 14/10mm Microducts

3, 4, 5 and 6 Multi-ways

HDPE Sheath

Testing to guidelines set in IEC60794-5

PRODUCT DESCRIPTION

Microduct cabling systems are popular

solutions for building flexibility into a network,

they can be populated when needed and leave

spare capacity for future growth.

The ability to deferinitial installation costs

is a key advantage of an air blown cable

installation over traditional cable installations.

To facilitate the installation of Microblo

Microcables, a range of Protected Microducts

(multiways) into which Microcables can be

blown are available. The Flat Burial range of

Protected Microducts are constructed with

thick walled individual Microduct which are

suitable for direct burial by themselves.

The flat burial products adds a connecting

web in the construction to aid installation and

allow individual microducts to be branched

off for building and access applications.

PRODUCT PERFORMANCE

Temp - Operational: -40°C to +70°C

Temp - Storage: -40°C to +70°C

Temp - Installation: -10°C to +50°C

Product Data

3W 12/8mm

4W 12/8mm

5W 12/8mm

6W 12/8mm

MB03FB1208

MB04FB1208

MB05FB1208

MB06FB1208

Part Number

Microduct size = 12/8mm Outer diameter/Bore

Description Width

(mm)

Height

(mm)

Weight

(kg/km)

Max

Installation

Tensile Force

(N)

Min Bend

Radius

Installed

(mm)*

Min Bend

Radius Short

Term (mm)**

44

58

73

88

217.5

290

310

495

13

13

13

13

2520

3360

4200

5000

440

580

730

880

645

870

1095

1320

3W 14/10mm

4W 14/10mm

5W 14/10mm

6W 14/10mm

MB03FB1410

MB04FB1410

MB05FB1410

MB06FB1410

Part Number

Microduct size = 14/10mm Outer diameter/Bore

Description

49

66

83

100

290

380

490

580

15

15

15

15

3030

4040

5000

6000

490

660

830

1000

735

990

1245

1500

Width

(mm)

Height

(mm)

Weight

(kg/km)

Max

Installation

Tensile Force

(N)

Min Bend

Radius

Installed

(mm)*

Min Bend

Radius Short

Term (mm)**

Page 144: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

143

Brand-Rex Air Blown Fibre – MicroBloMicroBlo Direct Burial Protected MicroDucts

A I R B L O W N F I B R E S Y S T E M S

7/3.5mm, 12/8mm and 14/10mm Microducts

1, 2, 4, 7, 12, 19 and 24 Multi-ways

HDPE Sheath

Testing to guidelines set in IEC60794-5

PRODUCT DESCRIPTION

Microduct cabling systems are popular

solutions for building flexibility into a network,

they can be populated when needed and leave

spare capacity for future growth.

The ability to defer initial installation costs

is a key advantage of an air blown cable

installation over traditional cable installations.

To facilitate the installation of Microblo

Microcables, a range of Protected Microducts

(multiways) into which Microcables can be

blown are available. The Direct Burial range

of Protected Microducts are constructed with

thick wall, direct burial individual microducts

with an overall HDPE sheathing making them

suitable for direct burial applications.

PRODUCT PERFORMANCE

Temp - Operational: -40°C to +70°C

Temp - Storage: -40°C to +70°C

Temp - Installation: -10°C to +50°C

HDPE Sheath

Product Data

1W 7/3.5mm

2W 7/3.5mm

4W 7/3.5mm

7W 7/3.5mm

12W 7/3.5mm

19W 7/3.5mm

24W 7/3.5mm+1W 14/10mm

MB01DB0735

MB02DB0735

MB04DB0735

MB07DB0735

MB12DB0735

MB19DB0735

MB24DB0735

Part Number

Microduct size = 7/3.5mm Outer diameter/Bore

Description Diameter

(mm)*

Weight

(kg/km)

Installed

(mm)

Installation Tensile

Force (N) (Max)

Min Bend

Radius Installed

(mm)**

Min Bend

Radius Short

Term (mm)***

7

15.5

18.4

22.5

29.5

36.5

43

28

83.4

145

230

372

620

844

390

780

1560

2730

4680

7400

9400

70

155

184

225

295

365

430

105

232.5

276

337.5

442.5

547.5

645

Microducts

1W 12/8mm

2W 12/8mm

4W 12/8mm

7W 12/8mm

MB01DB1208

MB02DB1208

MB04DB1208

MB07DB1208

Part Number

Microduct size = 12/8mm Outer diameter/Bore

Description Diameter

(mm)*

Weight

(kg/km)

Installation Tensile

Force (N) (Max)

Min Bend

Radius Installed

(mm)**

Min Bend

Radius

Short Term

(mm)***

12

25.5

30

37.5

59

160

305

495

840

1680

3360

5880

120

255

300

375

180

382.5

450

562.5

1W 14/10mm

2W 14/10mm

4W 14/10mm

7W 14/10mm

MB01DB1410

MB02DB1410

MB04DB1410

MB07DB1410

Part Number

Microduct size = 14/10mm Outer diameter/Bore

Description Diameter

(mm)*

Weight

(kg/km)

Installation Tensile

Force (N) (Max)

Min Bend

Radius Installed

(mm)**

Min Bend

Radius

Short Term

(mm)***

14

29.5

35

43.5

72

191

370

615

1010

2020

4040

7070

140

295

350

435

210

442.5

525

652.5

Page 145: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

144

Brand-Rex Air Blown Fibre – MicroBloMicroBlo Indoor Protected MicroDucts

A I R B L O W N F I B R E S Y S T E M S

5/3.5mm, 10/8mm and 12/10mm Microducts

1, 2, 4, 7, 12, 19 Multi-Ways

LSHF Microduct & Sheath

Testing to guidelines set in IEC60794-5

PRODUCT DESCRIPTION

Microduct cabling systems are popular

solutions for building flexibility into a network,

they can be populated when needed and

leave spare capacity for future growth.

The ability to defer initial installation costs

is a key advantage of an air blown cable

installation over traditional cable installations.

To facilitate the installation of Microblo

Microcables, a range of Protected Microducts

(multiways) into which Microcables can be

blown are available. The Indoor range of

Protected Microducts are constructed with

Low Smoke Halogen Free microduct which

are sheathed with an overall LSHF protective

layer. This product is ideal for providing

access into a building and can be simply

joined to a DI or DB Microduct to allow the

cable to be blown straight into the building.

PRODUCT PERFORMANCE

Temp - Operational: -40°C to +70°C

Temp - Storage: -40°C to +70°C

Temp - Installation: -10°C to +50°C

LSHF Sheath

Product Data

1W 5/3.5mm

2W 5/3.5mm

4W 5/3.5mm

7W 5/3.5mm

12W 5/3.5mm

19W 5/3.5mm

MB01IN0535

MB02IN0535

MB04IN0535

MB07IN0535

MB12IN0535

MB19IN0535

Part Number

Microduct size = 5/3.5mm Outer diameter/Bore

Description Diameter

(mm)*

Weight

(kg/km)

Installation Tensile

Force (N) (Max)

Min Bend

Radius Installed

(mm)**

Min Bend

Radius Short

Term (mm)***

5

11.5

13.6

16.5

21.5

26.5

10

41

65

109

182

262

100

200

400

700

1200

1900

50

115

136

165

21.5

265

75

172.5

204

247.5

322.5

397.5

1W 10/8mm

2W 10/8mm

4W 10/8mm

7W 10/8mm

12W 10/8mm

MB01IN1008

MB02IN1008

MB04IN1008

MB07IN1008

MB12IN1008

Part Number

Microduct size = 10/8mm Outer diameter/Bore

Description Diameter

(mm)*

Weight

(kg/km)

Installation Tensile

Force (N) (Max)

Min Bend

Radius Installed

(mm)**

Min Bend

Radius Short

Term (mm)***

10

21.5

25.6

31.5

41.5

29

103

182

319

440

280

560

1120

1900

3360

100

215

256

315

415

150

322.5

384

472.5

622.5

1W 12/10mm

2W 12/10mm

4W 12/10mm

7W 12/10mm

MB01IN1210

MB02IN1210

MB04IN1210

MB07IN1210

Part Number

Microduct size = 12/10mm Outer diameter/Bore

Description Diameter

(mm)*

Weight

(kg/km)

Installation Tensile

Force (N) (Max)

Min Bend

Radius Installed

(mm)**

Min Bend

Radius Short

Term (mm)***

12

25.5

30

37.5

40

133

230

376

340

680

1360

2300

120

255

300

375

180

382.5

450

562.5

LSHF Microduct

Page 146: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

145

3mm Straight

Connector:

For connecting 2 equal

Straight - Push/Pull

Straight - Screw Retention

End Stop

Connector End Plug

Bulkhead Mounted

Connector

Dust Cap

Gas Blocking ‘T’ Piece

8mm to 5mm Reducer

Standard to Direct Burial

mating connector

Termination Fibre Diverter

8mm to 5mm Stem

Converter

Water Blocking Straight

30-0301-00

-

30-0304-00

-

-

30-0307-05

-

-

-

-

-

-

Connector Type 3/2.1 mm 5/3.5 mm 7/3.5 mm 8/6 mm 10/8 mm 12/8 mm 12/9.4 mm 14/9.4 mm

30-0501-00

30-0502-00

30-0504-00

30-0505-09

30-0506-09

30-0507-05

30-0508-00

30-5801-00

-

-

30-5810-05

30-0503-00

30-0721-00

30-0704-00

30-0707-05

30-5701-00

(7/3.5mm to 5/3.5mm)

-

-

-

30-0801-00

30-0802-00

30-0804-00

30-0805-09

-

30-0807-05

30-0808-00

-

-

30-0809-05

-

-

30-1001-00

-

30-1004-00

-

-

30-1007-05

-

-

-

-

-

30-1003-00

30-1221-00

-

30-1204-00

-

-

30-1207-05

-

-

30-0201-00

(12/8mm to 10/8mm)

-

-

-

301201-00

-

30-1204-00

-

-

30-1207-05

-

-

-

-

-

30-1203-00

30-1421-00

-

30-1404-00

-

-

30-1407-05

-

-

30-2401-00 (14/9.4mm

to 12/9.4mm)

-

-

-

Blolite and MicroBlo microduct connectivity

PRODUCT DESCRIPTION

Within MicroBlo and Blolite a range of plastic bodied pneumatic tube connectors are used for tube routing. The connectors have a variety of forms

and are all rated for the maximum working pressure of 10 Bar. The connectors are installed with a simple push-pull technique and can be re-used

several times.

A I R B L O W N F I B R E S Y S T E M A C C E S S O R I E S

Straight Connector:

For connecting 2 equal

End Plug:

For blocking a straight

connector when a later

connection is required.

Gas Blocking ‘T’:

For use with resin to

provide a gas blocking

seal where required.

8mm - 5mm Reducer:

To reduce from 8mm

- 5mm MicroDuct at

termination point.

Bulkhead Connector:

For attaching a

microduct to a panel

or wall box.

Dust Cap:

For preventing the

ingress of dust during

installation.

Straight Screw Connector:

microducts and eliminating

movement at joint.

End Stop:

For blocking of the end

of a redundant tube or

temporary sealing.

Termination Splitter /

Stem Converter:

For use at the end of

a duct route to divert

fibres into different

termination points.

Page 147: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

146

Brand-Rex Air Blown FibreTools

A I R B L O W N F I B R E S Y S T E M A C C E S S O R I E S

Radial Tube Cutter Duct Stripping Tool

4.5mm - 29.00mm

Duct Stripping Tool

19.0mm - 40.00mm

Duct Testing Kit

54-0100-00

54-0201-00

54-0202-00

54-0300-00

50-0506-00

Radial Tube Cutter

Duct Stripping Tool 4.5mm - 29.00mm

Duct Stripping Tool 19.00mm - 40.00mm

Duct Stripping Tool Spare Blades

Duct Testing Kit

Part Number

Product Part Numbering

Page 148: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

147

MT Connect is a high performance, pre-

terminated, modular, Optical Fibre cabling

system based on MT ferrule connector

technology. MT ferrule is the building block

of the system, it accommodates up to 12

fibres in a single ferrule. The array is made

of a precision moulded thermoplastic and

uses metal guide pins, precise housing

dimensions and keying to ensure fibre

alignment and maintenance of polarity

when mating. The housing uses a push-pull

latching mechanism, with audible click, to

ensure proper connection.

Our product set may be used in the general

office to speed the installation of backbone

desk or in the datacentre where multiple,

point to point, fibre connections between

distribution racks and equipment racks

can be quickly and efficiently installed,

maintained and changed as required.

The MT Connect system has unique

advantages over conventional optical

fibre cabling:

connector ensure faster installation of

multiple fibre links

pathways and racks giving more space for

air circulation

add and change environment and simple,

fast maintenance and repair

quality assured by factory termination

of connectors

MT Connect is available in OM3, OM4 or OS1

performance grade cabling and comprises a

set of parts which enable any configuration

of link to be simply and quickly built.

M T C O N N E C T P R E T E R M I N AT E D F I B R E S Y S T E M S

Page 149: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

148

M T C O N N E C T P R E T E R M I N AT E D F I B R E S Y S T E M S

Operating temperature range (ºC)

Store temperature range (ºC)

-20 to +60

-20 to +60

OM3 performance 50/125 Multimode

OM4 peformance 50/125 Multimode

OS1 Performance Singlemode

Fibre Type & Cable Performance Grade

850

1300

850

1300

1310

1550

wavelength(nm)

3.5

1.5

3.5

1.5

0.5

0.4

Maximum Attenuation

(dB/km)

Typical Cable Attenuation

(dB/km)

2.6

0.6

2.6

0.6

0.3

0.2

(1) angled polish face(2) Durability: <0.3dB change in 500 mating cycles

Multimode

Singlemode

Connector Type

0.35

0.20

0.35

0.20

Insertion Loss (dB) Return Loss (dB)

Typical Maximum Typical Minimum

0.75

0.40

0.50

0.30

25

25

65

65

20

20

55

55

MPO (2)

LC or SC

MPO (1) & (2)

LC or SC (1)

Connector Performance - MT Connect MPO Solution

MT FERRULE TECHNOLOGY

The MT ferrule is the building block of the system, it accommodates up

to 12 fibres in a single ferrule. The array is made of a precision moulded

thermoplastic and uses metal guide pins, precise housing dimensions

and keying to ensure fibre alignment and maintenance of polarity when

mating. The housing uses a push-pull latching mechanism, with audible

click, to ensure proper connection.

Specification and Performance

The MT Connect system is made up of standards compliant component

products which are designed and manufactured to conform to the

requirements of the structured wiring cabling standards ISO/IEC

11801:2002 amendments 1 & 2, EN 50173-1 and TIA 568 and the

datacentre cabling standards EN50173-5, IEC 24764 and TIA 942.

The high quality of the connector system allows multi-connector links

to be configured with the MT Connect set whilst still meeting the

optical budget of high speed applications. MT Connect supports all

of the applications recognised in the standards including Ethernet

and Fibre Channel technologies including 10/40/100GbE speeds.

The micro-distribution cables used in the cable array assemblies

are smaller and lighter than conventional optical cable products

and offer the added benefits of reducing the space taken in pathways,

lightening loads in trays, and minimising the possibility of adversely

affecting cooling under-floor air flows by creating air dams in

cable pathways.

MT Connect MPO System

MT Connect MPO Solution is a high performance, pre-terminated,

modular, Optical Fibre cabling system based on MT ferrule connector

technology.

This product set may be used in the general office to speed the

or in the data centre where multiple, point to point, fibre connections

between distribution racks and equipment racks can be quickly and

efficiently installed, maintained and changed as required.

MT Connect MTP® SuperSet System

MT Connect MTP® SuperSet is an ultra high performance,

pre-terminated, modular, Optical Fibre cabling system based

on MT ferrule connector technology.

The product set is equally suitable for installation in the general

office and the datacentre, however it also offers added optical and

mechanical benefits. The SuperSet improves the link performance by

preserving the signal power through use of low loss, higher precision

connectivity. This higher performance affords designers the flexibility

to incorporate multiple connectors within the system whilst meeting

the demanding optical budget. As a result the MTP SuperSet is ideally

suited to installations where an upgrade path to multi-lane higher

speed transmissions of 40 &100GbE is required. This element of future

proofing is invaluable.

(1) angled polish face

Multimode

Singlemode (1)

Connector Type

0.10

0.10

0.10

0.10

Insertion Loss (dB) Return Loss (dB)

Typical Maximum Typical Minimum

0.35

0.20

0.35

0.20

-

-

-

-

20

20

60

65

MTP® Low Loss

Low Loss LC

MTP® Low Loss

Low loss LC

Connector Performance - MT Connect MTP® Solution

Page 150: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

149

1

A

2

3

4

5

6

7

8

9

10

11

12

M T C O N N E C T P R E T E R M I N AT E D F I B R E S Y S T E M S

A – B Cord

1

21

2

Rx

Tx

Type ‘A’ Adaptor

Type ‘A’ TransitionDuplex

Type ‘C’ Array Cable

Simplex

connector 12

Connector

position 1

Connector

position 12

Key down

Pinned Key down Key up

Key up Connector

position 1

Connector

position 12

Connector

position 1

Connector

position 12

Key down

No pins No pins

1a

1b

2a

2b

3a

3b

4a

4b

5a

5b

6a

6b

LGX box or Breakout Assembly Cable Assembly

Rx

Tx

POLARITY

MT Connect uses the TIA568B.1-7:2006 method ‘C’ for both the

multi-mode and single-mode fibre systems.

Method ‘C’ comprises type ‘A’ transitions (breakout assemblies

or LGX boxes), ‘Key up’ to ‘Key down’ adaptors and type ‘C’ cable

assemblies.

This scheme allows the use of standard cross-over patch cords

at both ends of the system for connection to end equipment,

it accomodates low reflectance singlemode and multi-mode

connectors and it uses common transition parts.

For the end user this is the simplest, and most user friendly, polarity

method in the standard. MT Connect is simple to install, operate

and maintain.

The fibre coding scheme within the array cables, and in the

breakout assemblies, is also standard:

Fibre no. 1 2 3 4 5 6 7 8 9 10 11 12

colour Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

TIA Method C:

Cord Type Cord TypeTransition Method Adaptor MethodAdaptor Method Transition MethodArray Cable Type

A to B A to BAA

‘Key up’ to ‘key down’A

‘Key up’ to ‘key down’AC

‘flipped pairs’

TYPICAL LINK CONFIGURATION

This product set is based on open standards and is compatible and interoperable with other standards compliant MPO connectivity products

which use TIA568 polarity method C.

Page 151: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

150

M T C O N N E C T P R E T E R M I N AT E D F I B R E S Y S T E M S

PRODUCT DESCRIPTION

These modular panel assemblies are used to

terminate backbone cables at the distributor or

equipment outlet ends and also to interface to

patch cords or equipment cords.

The 1U panel fits into standard 19” racks and

accommodates up to 4 plug in units. LGX

cassettes, MTP® adaptor plates, LC 24 fibre

faceplates or blanking plates or 5 port Snap-in-

Jack faceplates are available as units.

The 3U panel fits into standard 19” racks and

accommodates up to 288 fibres using up to 12

cassettes to offer a high density solution. The

panel can also accommodate 5 port snap-

in-jack faceplates to offer a versatile hybrid

configuration. Cable management is attached

on to the front of the panel to act as a support

for the cabling with the fixed labelling tray,

located on the front of the panel.

The panels are ideal for data centre installations

where multiple point to point fibre connections

between distribution racks and racks can be

installed, maintained and changed quickly and

efficiently.

The MTP® system is simple and flexible and can

accommodate up to 96 LC connections per U

using LGX cassettes, or up to 288 connections

per U using MTP® adaptor plates.

LGX cassettes are available in high performance

OM3, enhanced OM4 and OS1/OS2 types.

MT Connect MTP® Pre-Terminated Fibre SystemsPanel Assemblies

Product Part Numbers

* The HD 5 Port SIJ Faceplate is not equipped with jacks, to be ordered separately.

19” 1U 4 Module MTP® Panel

19” 3U 12 Module MTP® Panel

24 fibre OM3 Cassette, 24 Low Loss LC’s & 2 pinned MTP Adaptors

24 fibre OM4 Cassette , 24 Low Loss LC’s & 2 pinned MTP Adaptors

24 fibre single mode Cassette

12 fibre OM3 Cassette,12 Low Loss LC’s & 1 pinned MTP Adaptor

12 fibre OM4 Cassette,12 Low Loss LC’s & 1 pinned MTP Adaptor

12 fibre O08/OS2 Cassette,12 Low Loss LC’s & 1 pinned MTP Adaptor

5 Port Snap-in-Jack Faceplate for RJ45 jacks*

6 Way MTP® Adapter Faceplate

Blank Faceplate

24 Fibre LC Adapter Faceplate - SingleMode

24 Fibre LC Adapter Faceplate - MultiMode

Description

MTPHD2

MTPHD3U122

SCAHDTMLCOM3242

SCAHDTMLCOM4242

SCAHDTMLC008242

SCAHDTMLCOM3122

SCAHDTMLCOM4122

SCAHDTMLC008122

MTFHD5SIJ2

STFHDM62

MTFHDBLK2

MTFHDLCSM2

MTFHDLCMM2

Part No.

1

1

1

1

1

1

1

1

10

5

5

5

5

Quantity per pack

5 Port Snap-in-Jack Faceplate Compatibility Chart

Augmented Category 6 Shielded Tool free jack

Category 6 Shielded Tool free jack

Category 6 Unshielded Tool free jack

AC6JAKS000

C6CJAKS000

C6CJAKU002

Description Part No.

Page 152: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

151

Part Number Breakdown/example

M T C O N N E C T P R E T E R M I N AT E D F I B R E S Y S T E M S

PRODUCT DESCRIPTION

MTP® Hybrid breakout units are made up of

12 fibres LSZH jacketed cables terminated at

one end in pinned MTP® Low Loss connectors,

through a bifurcation unit, to LC duplex low

loss connectors (high precision SM tolerance

versions) terminated to 2mm OD simplex

cables.

These are used to connect equipment in racks

to MTP® terminated backbone cables.

The assemblies are available in OM3, enhanced

OM4 and OS1/OS2 performance grade.

Breakout Assemblies are also available with

staggered leg lengths for ease of installation

where the legs of the breakout assembly are

tailored to fit; the part number then becomes

a unique reference for the type of breakout

required.

Please see examples on the left for ordering

information.

Ordering Information:

The assemblies are available in standard

lengths of 2 & 3m as standard.

Custom engineered lengths are also available

on request.

The assemblies are delivered as coils.

MT Connect MTP® Pre-Terminated Fibre SystemsBreakout Assemblies

Harness

Type 1

Type 2

FO type

OM4

OM4

Trunk fibres1&2 (mm)

1000

1000

Trunk fibres 3&4 (mm)

1000

1000

Trunk fibres 5&6 (mm)

988

960

Trunk fibres 7&8 (mm)

976

948

Trunk fibres 9&10 (mm)

940

936

Trunk fibres 11&12 (mm)

928

924

Overall length (m)

2.5

2.5

Brand-Rex part no

S TM LC OM4 12 025 T01

S TM LC OM4 12 025 T02

The table below shows 2 examples of specified breakout staggered assemblies:

S= Superset TM = MTP® Low Loss

with pins

LC = LC Duplex with

connector clip OM3 = MM 12 = No. of fibres Overall length

Unique number for

customer specification

breakout cable

OM4 = MM 025 = 2.5m T01 = Type 1

008 = SM 033 = 3.3m etc T01 = Type 2

S TM LC OM3 12 025 T01

Page 153: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

152

M T C O N N E C T P R E T E R M I N AT E D F I B R E S Y S T E M S

MT Connect MTP® Pre-Terminated Fibre SystemsCable Assemblies

Cable Assembly Type ‘C’

No pins No pins

Key up

Cable ID label Cable ID label

Key down

PRODUCT DESCRIPTION

Cable assemblies are made up of 12 fibre LSZH

jacketed cables terminated at both ends in

MTP® Low Loss connectors (without pins).

They are ideal for used as back bone or

distribution racks.

The assemblies are available in OM3, enhanced

OM4, and OS1/OS2 to suit the needs of every

network.

Ordering Information:

The cable assemblies are available in standard

lengths of 1, 3, 5, 10, 20, 30, 50 and 100m.

Custom engineered lengths are also available

on request.

The assemblies are delivered as coils in lengths

up to 50m and on reels in lengths over 50m.

Single-mode cables are yellow.

OM3 Multi mode cables are aqua

OM4 Multi mode cables are heather violet

* SMF terminations are angled polished

S T, or

S TM (with pins)

MTP® connector

Compact = C

Cable Type Cable assembly polarity scheme MTP® Low Loss connector Cable performance

CT, or

TM (with pins)

OM3, or

OM4, or

008*

Length (m)No of fibres(1)

12 ZZZ Z

Part Number Breakdown/example

ST C C T OM4 12 0050

Note 1: There are 4 figures at the end of this part number for length. The 4th figure is a decimal.

Note 2: Compact cables are 3mm OD.

Length -0/+20 cm

Page 154: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

153

M T C O N N E C T P R E T E R M I N AT E D F I B R E S Y S T E M S

PRODUCT DESCRIPTION

Modular panel assemblies are used to

terminate backbone cables at the distributor or

the equipment outlet ends and also to interface

to patch cords or equipment cords.

The 1U panel fits into standard 19” racks and

accommodates up to 4 plug in units. LGX

boxes, MPO adaptor plates , 5 Port Snap-in-Jack

faceplates and blanking plates are available as

units.

The system is simple and flexible and

accommodates up to 288 fibre terminations

in 1U.

Up to 24 quad LC connections per U can be

provided using LGX boxes. Or, up to 288

connections per U can be achieved using

4 of the 6 way MPO adaptor plates.

The LGX boxes are available in high

performance OM3, OM4 or OS1 (008) types.

MT Connect MPO Pre-Terminated Fibre SystemsPanel Assemblies

19” Panel with four apertures on the front face for clipping in modules, blanks or adaptor plates

19” Panel with twelve apertures in the front face for clipping in modules, blanks or adapter plates

LGX ‘clip in’ module with a pinned MPO at the rear, 12 LCs on the front face, OM3 performance

LGX ‘clip in’ module with 2 pinned MPOs at the rear, 24 LCs on the front face, OM3 performance

LGX ‘clip in’ module with a pinned MPO at the rear, 12 LCs on the front face, OM4 performance

LGX ‘clip in’ module with 2 pinned MPOs at the rear, 24 LCs on the front face, OM4 performance

LGX ‘clip in’ module with a pinned MPO at the rear, 12 LCs on the front face, OS1 performance

LGX ‘clip in’ module with 2 pinned MPOs at the rear, 24 LCs on the front face, OS1 performance

Adaptor Plate - clip in, with 6 ‘type A’ ‘key up’ to ‘key down’ MPO/MTP adaptors

Blanking Plate - clip in, to cover open apertures on the panel front face

5 Port Snap-in-Jack Faceplate for RJ45 Jacks*

Part Number

Product Part Numbering

5 Port Snap-in-Jack Faceplate Compatibility Chart

Augmented Category 6 Shielded Tool free jack

Category 6 Shielded Tool free jack

Category 6 Unshielded Tool free jack

AC6JAKS000

C6CJAKS000

C6CJAKU002

Description Part No.

* Jack Compatible

MTPHD2

MTPHD3U122

MTC AHD ML OM3 122

MTC AHD ML OM3 242

MTC AHD ML OM4 122

MTC AHD ML OM4 242

MTC AHD ML 008 122

MTC AHD ML 008 242

STFHDM62

MTFHDBLK2

MTFHD5SIJ2

Page 155: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

154

Product Part Numbering

MPO to LC BreakOut Assembly - OM3 - 2m overall, 1m legs

MPO to LC Breakout Assembly - OM3 - 3m overall, 1m legs

MPO to SC Breakout Assembly - OM3 - 2m overall, 1m legs

MPO to SC Breakout Assembly - OM3 - 3m overall, 1m legs

MPO to LC Breakout Assembly - OM4 - 2m overall, 1m legs

MPO to LC Breakout Assembly - OM4- 3m overall, 1m legs

MPO to SC Breakout Assembly - OM4 - 2m overall, 1m legs

MPO to SC Breakout Assembly - OM4 - 3m overall, 1m legs

MPO to LC Breakout Assembly - OS1 - 2m overall, 1m legs

MPO to LC Breakout Assembly - OS1 - 3m overall, 1m legs

MPO to SC Breakout Assembly - OS1 - 2m overall, 1m legs

MPO to SC Breakout Assembly - OS1 - 3m overall, 1m legs

MTM LC OM3 12 02

MTM LC OM3 12 03

MTM SC OM3 12 02

MTM SC OM3 12 03

MTM LC OM4 12 02

MTM LC OM4 12 03

MTM SC OM4 12 02

MTM SC OM4 12 03

MTM LC 008 12 02

MTM LC 008 12 03

MTM SC 008 12 02

MTM SC 008 12 03

Part Number

M T C O N N E C T P R E T E R M I N AT E D F I B R E S Y S T E M S

PRODUCT DESCRIPTION

MPO hybrid breakout unit is made up a 12 fibre

LSHF jacketed cable terminated at one end in

MPO connectors, through a bifurcation unit, to

SC or LC connectors terminated on 2mm OD

simplex cables.

These are used to connect equipment in racks

to MPO terminated backbone cables.

The assemblies are available in OM3, OM4 or

OS1 (008) performance grade

Ordering Information:

The assemblies are available in standard

lengths of 2m & 3m as standard.

Custom engineered lengths are also available

on request.

The assemblies are delivered as coils.

MT Connect MPO Pre-Terminated Fibre SystemsBreakout Assemblies

MTM

MPO Connector with pins

LC or SC

Duplex Connector Cable performance Number of fibres

‘OM3’, or

‘OM4’, or

or 008

12

Overall length (m)(1)

ZZ

(1) Breakout unit legs are a standard 1m long.

Part Number Breakdown:

Page 156: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

156

M T C O N N E C T P R E - T E R M I N AT E D F I B R E S Y S T E M S

PRODUCT DESCRIPTION An MPO cable assembly is made up of 12 fibre LSHF jacketed cable terminated at both ends in MPO connectors (without pins). These are used as backbone or horizontal cable interconnections between distribution racks.

The assemblies are available in a range of performance levels (OM3, OM4 or OS1 (008) types) and in different lengths to suit the needs of the network.

Ordering Information:

Assemblies are available in standard lengths of 1, 3, 5, 10, 20, 30, 50 and 100m.

Custom engineered lengths are also available on request.

Assemblies are delivered as coils in lengths up to 50m long and on reels in lengths over 50m.

Single-mode cables are yellow. OM3 Multi mode cables are aqua OM4 Multi mode cables are heather violet

MT Connect MPO Pre-Terminated Fibre SystemsCable Assemblies

Product Part Numbering

Cable assembly (LSHF) - OM3 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM3 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM3 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM3 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM3 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM3 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM3 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM3 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM4 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM4 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM4 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM4 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM4 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM4 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM4 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OM4 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OS1 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OS1 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OS1 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OS1 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OS1 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OS1 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OS1 cable terminated in MPOs (no pins)

Cable assembly (LSHF) - OS1 cable terminated in MPOs (no pins)

1

3

5

10

20

30

50

100

1

3

5

10

20

30

50

100

1

3

5

10

20

30

50

100

MT CC MT OM3 12 001

MT CC MT OM3 12 003

MT CC MT OM3 12 005

MT CC MT OM3 12 010

MT CC MT OM3 12 020

MT CC MT OM3 12 030

MT CC MT OM3 12 050

MT CC MT OM3 12 100

MT CC MT OM4 12 001

MT CC MT OM4 12 003

MT CC MT OM4 12 005

MT CC MT OM4 12 010

MT CC MT OM4 12 020

MT CC MT OM4 12 030

MT CC MT OM4 12 050

MT CC MT OM4 12 100

MT CC MT 008 12 001

MT CC MT 008 12 003

MT CC MT 008 12 005

MT CC MT 008 12 010

MT CC MT 008 12 020

MT CC MT 008 12 030

MT CC MT 008 12 050

MT CC MT 008 12 100

Length Part Number

MT or

MTM (with pins)

MPO Connector

MT or

MTM (with pins)

MPO Connector

C = compact cable

Cable type Cable Assembly Cable performance Number of fibres(1)

C

OM3, or

OM4, or

008

12

ZZZ

length (m)

(1) Other numbers of fibres are available on request, e.g. 8 ways. In 8 fibre assemblies fibre positions 1, 2, 3, 4 & 9, 10, 11, 12

are normally terminated in the12 way array connector.

Part Number Breakdown:

155

Page 157: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

156

The Brand-Rex datacentre cabinets and

racks range offers the ultimate solution

for management of fibre and copper in

datacentres and telecoms rooms. The

unique, flexible and effective range is the

ideal solution to support the mission critical

applications of the modern day datacentre.

These ground breaking solutions have been

designed, in conjunction with customers,

with an emphasis on minimising on-site

installation times, improving accessibility

to cabling and to providing modularity to

enhance the overall operational flexibility.

The High Density Solutions are designed to

solve the problems of today’s networking

environment, providing unique working

and cabling accessibility to completely

transform cabinet installation layouts,

onsite installation and on-going system

management.

D ATA C E N T R E C A B I N E T S A N D R A C K S

Page 158: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

157

434500434

20

35

21

33

900

D ATA C E N T R E C A B I N E T S A N D R A C K S

Brand-Rex Datacentre Cabinets and RacksHigh Density Fibre Management Cabinet

Up to 912 Duplex ports in a 900mm (W)

x 500mm (D) footprint, 45U Frame.

Easy patching access reduces installation time.

Maximises useable space and minimise

footprint.

Open construction for ease of cross-patching.

Minimum bend radius maintained

throughout system.

Unique manifold and duct routing system

which allows easy installation of cables.

PRODUCT DESCRIPTION

The Brand-Rex High Density Fibre Cabinet and

Panel offers the ultimate solution for management

of fibre in datacentres and telecoms rooms.

The solution is designed with an emphasis on

minimising on-site installation times, accessibility

to cabling and modularity to enhance its

operational flexibility. The cabinet is the first

fibre cabinet designed to solve the problems

of today’s networking environment. It provides

unique working and cabling accessibility to totally

transform cabinet installation layouts, onsite

installation and on-going system management.

PRODUCT CHARACTERISTICS

Applications

Installation

Brand–Rex Fibre patch panels, patch cords

and cable management products.

MECHANICAL SPECIFICATIONS

Dimensions / Weight

top and side panels, without fibre

Part NumberDescription

Full assembled racks including all panels and part no’s (loaded and part loaded)

Product Part Numbering

For corresponding High Density Fibre

Management Panel please see page 12

Page 159: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

158

Brand-Rex Datacentre Cabinets and RacksHigh Density Fibre Management Cabinet

Individual parts and accessories

Bolt Together Kit

DRCKITBB001

DRCKITBT001

DRCKITCN001

DRCFGT002

DRCFGB002

DRCFMDC002

DRCFMD002

DRCFCHS002

DRCFCS002

DRCFCHB002

20-0118-00

D ATA C E N T R E C A B I N E T S A N D R A C K S

Page 160: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

159

434500434

20

35

Brand-Rex Datacentre Cabinets and RacksHigh Density Copper Cabling Cabinet

D ATA C E N T R E C A B I N E T S A N D R A C K S

Reduced installation time

Network installations made easy

Maximising useable space and

minimise footprint

Totally open constructions for ease

of cross-patching

Flexible configuration

Enhanced thermal management

PRODUCT DESCRIPTION

The High Density Cabling Cabinet offers the

ultimate solution for management of cross-

connect cabling in datacentres and telecoms

rooms. The cabinet offers the ability to create a

preferred enclosure design configuration that

fits the needs of today’s working environment.

To tailor a solution to your requirements simply

begin with the basic frame and subsequently

add doors, side panels and top panels as

required. The range also has a comprehensive

array of accessories to suit all applications. If you

have any problems please contact our expert

customer service team for technical assistance.

PRODUCT CHARACTERISTICS

Applications

Installation

Copper and Fibre Patch cords, panels and

cable management products

MECHANICAL SPECIFICATIONS

Dimensions / Weight

Page 161: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

160

Brand-Rex Datacentre Cabinets and RacksHigh Density Copper Cabling Cabinet

HDC Back to Back Baying Bracket

1 x Earth Kit

HDC, 2 Bay Back to Back Computer Floor Plinth

Bolt Together Kit

DRCKITBB001

DRCKITER001

DRCACCCM001

DRCFPBB152

DRCKITBT001

DRCFANTP0209AS2

DRCACCCM002

DRCKITCN001

Product Part Numbering

D ATA C E N T R E C A B I N E T S A N D R A C K S

Page 162: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

161

2000

Brand-Rex Datacentre Cabinets and RacksHigh Density Distribution Equipment Rack

D ATA C E N T R E C A B I N E T S A N D R A C K S

Reduced installation time

Network installations made easy

Maximising useable space and

minimise footprint

Totally open constructions for ease

of cross-patching

Flexible configuration

Enhanced thermal management

PRODUCT DESCRIPTION

provides increased accessibility and has

a flexible modular design that can be

configured to suit small, corporate and

internet datacentres. The DER set can be

configured as an open frame to manage

the cabling at the distributors or as a closed

cabinet to safely secure servers and storage

equipment. The designs are modular and

flexible.

The logic of the modular, flexible systems

are the key benefits of this best in class

cable and equipment management system

range. Features also include vented and glass

door options, side panels and top panels

with cable access. These Cabinets have an

unparalleled level of flexibility, providing the

end user with the right cabinet for the right

application.

PRODUCT CHARACTERISTICS

Applications

Installation

Copper and Fibre Patch cords, panels and

cable management products

MECHANICAL SPECIFICATIONS:

Dimensions / Weight

Page 163: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

162

Fan tray lead 13 AMP

Fan tray lead IEC

Fan tray lead Schuko

DER, Standard Plinth Kit, 800 x 1000mm

DER, Standard Plinth Kit, 800 x 1200mm

1 x Earth Kit

1 x Heavy Duty Castor Kit

Bolt Together Kit

DRCFANTP0208AS2

DRCSPK0808

DRCSPK0810

DRCSPK0812

DRCKITER001

DRCKITCH001

DRCACCCM001

DRCACCCM002

DRCKITBT001

Catalogue Number

Brand-Rex Datacentre Cabinets and Racks

Product Part Numbering

D ATA C E N T R E C A B I N E T S A N D R A C K S

Page 164: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

163

D ATA C E N T R E C A B I N E T S A N D R A C K S

19’’ Finger Cable Management Bar

Cable Management Spools

Product Part Numbering

Catalogue Number

Reduced installation time

Network installations made easy

Maximising useable space and

minimise footprint

Totally open constructions for ease

of cross-patching

Flexible configuration

Standard cage nut fixings

Size options include 30U and 45U

PRODUCT DESCRIPTION

modular and easy-to-install system that can

also be applied to small, corporate and internet

datacentre environments. It can be used stand-

alone or in multiples. It is an ideal solution for

the main distribution area.The modular and

options and solutions to deal with issues of cable

access and routing that are common to today’s

high data rate networks and high performance

cabling. It offers the user a simple, modular and

easy-to-install system featuring smart, effective

cable management options and built-in flexibility

to cope with copper or optical cabling.

The combination of completely interchangeable

cable retention gates, doors, fingers and

to adapt his or her own specific needs.

Also, reconfiguration and modification of the

choice for cable management needs now, and in

the future.

MECHANICAL SPECIFICATIONS

Dimensions & Weight

PRODUCT CHARACTERISTICS

Applications & Installation

copper and fibre patch cords, panels and cable

management products

Brand-Rex Datacentre Cabinets and Racks

DRCACCCMS001

Page 165: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

164

In today’s world of high speed connectivity

the importance of 100% availability of IT

services is business critical. The introduction

of best practice standards for IT Service

Management has set the benchmark as IT

global standard for IT Service Management.

At the core of an IT Service Management

framework are the configuration, change

and incident management processes. The

accuracy and quality of the information

contained within the main configuration

in ensuring the effectiveness, efficiency

and quality of all associated IT Service

Management processes.

Traditionally, configuration management

is one of the most difficult disciplines

to implement due to the manual effort

needed to maintain accurate records of the

constant changes to the IT infrastructure.

The management of changes is also highly

critical, as service delivery managers must

know the exact implications of carrying out

any changes before they take place.

Creating such systems and processes based

upon a traditionally managed cabling

infrastructure is an almost impossible task.

The Brand-Rex Intelligent Infrastructure

Solution, SmartPatch , a highly advanced

overlay system allows network managers

the opportunity to have real time visibility

of network connectivity and utilisation.

The system provides simple and controlled

management and recording of common

network changes such as those forced

by office moves and terminal additions.

SmartPatch also gives multi-site businesses

the tools to effectively monitor and manage

all sites from a central location.

Page 166: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

165

What is SmartPatch?

SmartPatch is a highly advanced overlay system that allows network

managers the opportunity to have real time visibility of network

connectivity and utilisation. The system provides simple and

controlled management and recording of common network changes

such as those forced by office moves and terminal additions.

Referred to as an Intelligent Infrastructure Management System

effectively monitor and manage all sites from a central location.

The Solution

By adopting Intelligent Infrastructure Management tools as a key

part of an IT Service Management strategy, IT Managers can create

an infrastructure platform capable of addressing these problems.

The ultimate goal is the provision of a 100% accurate, real-time,

trusted source of connectivity and asset information that can be

incorporated within the core CMDB, and that can be utilised to

enhance all associated IT service management tools and processes.

Any physical additions or changes to the network configuration

are quickly and accurately planned and executed before being

automatically updated and reflected across all management

processes, thereby optimising process efficiency and aiding

communication and co-ordination between work-streams.

can be instantaneously identified and forwarded to the appropriate

service management tool or team for rectification

The most significant benefits of the system may be

summarised as:

Intelligent Infrastructure Management in the office

and in the datacentre

must be allocated to accommodate new application servers.

Planning of multiple cable routes is the most time consuming

element of the commissioning process and one that is highly

susceptible to error, this also extends into the standard office

environment. Commissioning a new, or moving an existing,

workstation requires significant time and resources to effectively

route the required services to the appropriate desktop location.

Prior to the introduction of IIM, the planning of service routing

and the subsequent creation of the resulting work orders was a

long and complex manual process. Adopting an IIM solution can

allow IT managers to simultaneously manage power, cooling and

environmental management applications along with space and

weight capacities to optimise the process of designing changes.

SmartPatch – the Smart Choice

SmartPatch is the market leading IIM solution, it provides an

auto-routing capability within its work order management function

that automatically designs routes for the required services to the

necessary location via the most efficient and effective cable links

available. The work orders required to execute the activity are

systematically created, issued and managed by the SmartPatch

system. Any actions that do not adhere 100% to the work order

are instantaneously identified and rectified if required.

a standard office environment could improve change efficiency

has been proven to reduce server service provisioning times by up

to 80% whilst simultaneously reducing the number of incidents

caused by poorly executed change. If incidents occur SmartPatch can

Successful adoption of IT Service management is critically

dependant on a trusted source of documentation.

Many organisations currently rely on tribal knowledge and/or

numerous sets of spreadsheets, diagrams, whiteboards, post-it

notes and the memory of long-serving individuals to document

the elements of their physical infrastructure. These methods are no

longer acceptable means of managing the IT infrastructure for those

organisations that are serious about IT service management.

Principles of Operation

SmartPatch uses a combination of software and hardware to

monitor and manage physical network connections. A topology of

scanners and intelligent patch panels, send and receive connectivity

application, providing real-time data and automatically updated

records. The software element of Smartpatch not only allows

the monitoring and management of physical connectivity, the

availability of a fully developed SDK means that the benefits of

accurate, real time information can also be integrated into most

commonly available network, facilities, configuration and helpdesk

management applications.

Page 167: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

166

A group of components designed to capture

physical connectivity information from

the patch panels and feed it into the SP4E

application and to communicate patching

guidance information from the application

to the panels. All units are 19"

offering a robust, compact, high density

scanning topology solution, with very low

power requirements and thermal output. This

system offers full scaleability from as few as 12

panels to massive comms rooms with no upper

limit to the size of the patching zone.

PRODUCT DESCRIPTIONS

SPMax Master collects and transmits

connectivity information between scanners

and the application. It can control multiple

comms rooms, includes an SNMP agent

and manages the scanning algorithm.

SPMax Expander is used to multiply the

capacity of a master allowing upto eight

scanners to communicate with a single master

port. Expanders may be stacked

to allow further expansion.

SPMax Master Expander is used as the

primary point of communication between the

application and a single, large comms room

such as a datacentre and may be connected to

further Expanders.

SPMax Scanners connect directly to the

copper and fibre patch panels and report either

directly to a Master or via Expansion. Scanners

monitor upto 24 panels and Mini Scanners

upto 12 panels.

SPMax Local Master is designed to monitor

small groups of panels, usually in remote

locations. It monitors upto 12 or 24 panels and

can communicate directly to the application

SPMax Indicator Controller controls the Rack

It is connected to the SmartPatch system

via an Expander port.

SPMax Security Controller controls up

to eight Indicators and also has the capacity

to control and monitor external devices

and sensors, up to a total of 32 devices.

Catalogue Number

SmartPatch SPMax Master 4 ports

SmartPatch SPMax Master Expander

SmartPatch SPMax Expander

SmartPatch SPMax Scanner

SmartPatch SPMax Mini Scanner

SmartPatch SPMax Splitter

SmartPatch SPMax Security Controller

SmartPatch SPMax Indicator Controller

SmartPatch Rack Indicator

SPMax Control Pad

Product Part Numbering

Brand-Rex Intelligent Infrastructure Management SolutionsSmartPatch SPMax Scanning Hardware

Page 168: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

167

PRODUCT DESCRIPTION

SmartPatch Copper Patch Panels are fully

compliant with the perfomance requirements

and are incorporated into the Brand-Rex

25 year warranty scheme.

Each panel is equipped with extra pins,

to allow the monitoring and recording

of patching status. This information is

communicated back to the server via scanner

attachment cords to the scanner system and

are used to trace connectivity or to offer

patching guidance to the engineer.

Note - When ordering panels it is important

to note the type of scanner attachment cord

required.

Brand-Rex Intelligent Infrastructure Management SolutionsSmartPatch Copper Patch Panels

Catalogue Number

SPV110CB4PR

Scanner Sockets

1 x B

2 x B

1 x B

1 x B

1 x B

1 x B

1 x B

1 x B

2 x B

-

-

UTP Panels Cat6

UTP Panels Cat6A

STP Panels Cat6

STP Panels Cat6A

Snap-In Panels

110 Voice Blocks

SmartPatch Voice Block 110, 24, SPMax

SmartPatch Voice Block 110, 48, SPMax

SmartPatch 110 Connector Block, 4 Pairs

Product Part Numbering

Page 169: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

168

PRODUCT DESCRIPTION

SmartPatch Cords are designed specifically

for use with Smart panels. They comprise of a

flexible 9 wire cable construction terminated

additional wire and pins, located outside

the standard 8 pins, are used to detect the

patching position of the cord.

Cords for the snap-in or retrofit solutions also

utilise an external blade in addition to the 9th

pin to make contact with the smart tabs on

the panel.

Part No.

SP1V1010PC010400

SP1V1010PC020400

SP1V1010PC030400

SP1V1010PC050400

SP2V1010PC010400

SP2V1010PC020400

SP2V1010PC030400

SP2V1010PC050400

UTP Patch cords Cat6

UTP Patch cords Cat6A

STP Patch cords Cat6

STP Patch cords Cat6A

Retrofit (Snap-in) Patch cords Cat6A

110 Cross-Connect Cords

SmartPatch 110 - 110, 1 Pair cord 1.0m

SmartPatch 110 - 110, 1 Pair cord 2.0m

SmartPatch 110 - 110, 1 Pair cord 3.0m

SmartPatch 110 - 110, 1 Pair cord 5.0m

SmartPatch 110 - 110, 2 Pair cord 1.0m

SmartPatch 110 - 110, 2 Pair cord 2.0m

SmartPatch 110 - 110, 2 Pair cord 3.0m

SmartPatch 110 - 110, 2 Pair cord 5.0m

Brand-Rex Intelligent Infrastructure Management SolutionsSmartPatch Copper Patch Cords

Page 170: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

169

Scanner Sockets

1 x B

1 x B

2 x B

-

-

2 x B

-

-

1 x A

1 x A

1 x A

-

-

-

-

-

-

Catalogue Number

SPFPPCM1MM48DC2

SPFPPCM1SM48DC2

SPFPPCM1SMA48DC2

LC Fibre Patch Panels

SmartPatch LC - LC Cassette

SmartPatch LC - MPO Cassette

SC Fibre Patch Panels

Fibre Accessories

Cable Ground Kit

Cable Entry Panel Kit

Protection Sleeve Holder

Product Part Numbering

Brand-Rex Intelligent Infrastructure Management SolutionsSmartPatch Fibre Patch Panels

PRODUCT DESCRIPTION

SmartPatch Fibre panels are fully compliant

with the perfomance requirements of the

latest standards and are incorporated into

the Brand-Rex 25 year warranty scheme.

Each panel is equipped with extra pins,

to allow the monitoring and recording

of patching status. This information is

communicated back to the server via

scanner attachment cords to the scanner

each port are used to trace connectivity or

to offer patching guidance to the engineer.

Note - When ordering panels it is important to note

the type of scanner attachment cord required.

Page 171: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

170

Catalogue Number

SPFPCSCSM010SC2

SPFPCSCSM020SC2

SPFPCSCSM030SC2

SPFPCSCSM050SC2

LC Patch cords

SC Patch cords

Product Part Numbering

Brand-Rex Intelligent Infrastructure Management SolutionsSmartPatch Fibre Patch Cords

PRODUCT DESCRIPTION

designed for use on SmartPatch installations.

They comprise, in all variants, two tight buffer

housed within a common outer jacket. Patch

mode and single-mode variants. Both ends are

terminated with a high performance hybrid

duplex fibre optic connector and a spring-

loaded electrical contact housed within a

common plastic shell.

Page 172: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

171

Catalogue Number

SPAACA015RD

SPAACA025RD

SPAACA120RD

SPAACB015RD

SPAACB025RD

SPAACB040RD

SPAACB120RD

Attachment cord 1.5m round Group A

Attachment cord 2.5m round Group A

Attachment cord 12m round Group A

Attachment cord 1.5m round Group B

Attachment cord 2.5m round Group B

Attachment cord 4m round Group B

Attachment cord 12m round Group B

Product Part Numbering

Brand-Rex Intelligent Infrastructure Management SolutionsSmartPatch Components

SPMax Splitter

scanning hardware, ensuring full utilisation

of the SPMax topology.

Scanner Attachment Cords

Scanner connection cables are used to connect

scanner. Cords are available in both flat and

round configurations in various lengths up to

panel layouts.

The variety of lengths available add flexibility

to the design possibilities using SmartPatch

panels, multiple panels in distributed racks

may be monitored by a single scanner,

allowing for simplified designs and reduced

power requirements.

Page 173: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

172

SmartPatch for the Enterprise (SP4E) v6.0

infrastructure management software package. It is designed

to bring a traditionally inert network infrastructure under

control and align it to other processes within the IT function,

particularly in terms of history and accountability. It does

this by providing real-time end-to-end physical connectivity

information and making it possible to monitor and maintain

a database of the IT infrastructure from any remote

location. SP4E allows the enterprise to automate network

documentation and maintenance procedures whilst constantly

providing real-time updates to the database.

How Does it Work?

relational database and works in combination via standard

System Administrator is provided with a real-time view of the

physical layer, including a combined view of the horizontal

and vertical sub-systems. A combination of graphics and real-

time information assist the Administrator in making critical

enterprise. These decisions are made for the daily maintenance

of the system, network troubleshooting and documentation

procedures. SP4E updates the network database to reflect the

MAC and IP details of network devices, as well as their physical

location in the network.

all software configurations removing the requirement for a

separate CAD module.

application is the Provisioning module. This module

allows users to implement individual MACs, departmental

reorganisations or even server deployments simply and

efficiently whilst adhering to user defined policies with simple

drag-and-drop operations.

Recommended

4 GB

Recommended

1 GB

Intel® Pentium® processor, >1.0GHz

Memory

Processor

Free Disk Space

Display

Networking

Additional Software

Client

Memory

Processor

Additional Software

Server

Brand-Rex SmartPatchSoftware

Page 174: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

173

To match client requirements, SP4E is now available in 3 standard

packages which may be enhanced with any of a range of

additional modules.

Contents of each of the packages are as follows:

Core -

Standard -

Advanced -

OPTIONAL MODULES

Provisioning Module – enables a user to assign system resources

and privileges in a fully automated environment. Significantly

improves the planning and provisioning process, including

workspace environments. The module also enables users to

incorporate their proprietary rules.

Report Centre – Can be ordered for additional users.

PBX Module

and the telephone end device.

Cable Test Results Module – contains data for link and channel

electrical cable tests for each port. Includes an option to view results

SitePro

via PDA.

SDK Developer – enables developers to integrate SP4E into 3rd

party or legacy applications.

SDK Runtime – enables customers to extend SP4E’s capabilities

throughout their organisation by integrating it with 3rd party or

legacy applications.

SiteBuilder – an Excel based utility that offers an alternative way

of uploading large amounts of SP4E related information onto the

SP4E database.

Additional Ports / Upgrades

The modular nature of the application means that it can be simply

upgraded to the latest version and can easily be scaled up to reflect

the changing size of the network.

Software Support

Support contracts are available in both update and upgrade

versions, offering in addition to helpline and troubleshooting,

free fixes, enhancements updates and/or version upgrades.

Packages

SP4E Core

SP4E Standard

SP4E Advanced

Modules

SP4E Discovery Module

SP4E Provisioning Module

SP4E Cable Test Results Module

SP4E SDK Runtime

Additional Ports

Demo License

Report Centre License

SiteBuilder License

SiteBuilder 2.5

Switch Driver

SP4E Customization for a new switch driver

Dashboard

SitePro License

SDK Developer

SDK Developer

Software Support Agreement

Basic Software Support Agreement

Premium Software Support Agreement

Part No.

SPASREPCADD

SPASDASH2-2

SPASSDKDEV

Software

Page 175: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

174

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

Page 176: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

Page 177: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

176

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

.....................................................................................................................................................................................................................................................................................................................................................................................................

Page 178: Structured Cabling Systems - Brand-Rex · PDF fileSTRUCTURED CABLING SYSTEMS COPPER SYSTEMS Page Augmented Category 6 Systems Page Category 7 Systems Page Category 6 Systems Page Category

www.brand-rex.com

[email protected]

brand-rex head officeviewfield industrial estate

glenrothes, fifeKY6 2RS

united kingdom

tel: +44 (0) 1592 772124 fax: +44 (0) 1592 775314

brand-rex asia pacific17/F prosperity centre

77-81 container port roadkwai chunghong kong

tel: +852 3620 2602 fax: +852 3621 0018

brand-rex central and eastern europe

tel: +420 222 363 657

brand-rex france120, rue jean jaurès

92 300 levallois perretfrance

tel: +33 (0) 1 70 98 78 25 fax: +33 (0) 1 70 98 78 36

brand-rex gmbhstorkower str.115

10407 berlingermany

tel: +49 (0) 30-290278-399 fax: +49 (0) 30-290278-397

brand-rex IMEAaspect tower - business bay

office No. 2206 zone bPO Box 123908

dubai united arab emirates

tel: +971 4 454 8644 fax: +971 4 451 8660

brand-rex milan via giovanni da udine, 34

20156 milano italy

tel: +39 02 3809 3711 fax: +39 02 30412014

brand-rex london72 cannon street

londonEC4N 6AE

united kingdom

tel: +44 (0) 207 489 7637 fax: +44 (0) 207 113 2239

brand-rex rome viale di trastevere, 248

00153 romaitaly

tel: +39 06 8360 0665

brand-rex nordic tel: +46 (0)704 621 950

brand-rex portugallagoas park edifício 8 – piso 0

2740-244 porto salvoportugal

tel: +351 21 421 4133 fax: +351 21 421 4135

brand-rex spainavda puente cultural

10 edif a, pt 1 puerta 1 28702 san sebastián de los reyes

spain

tel: +34 914 905 919 fax: +34 916 573 331

brand-rex speciality cabling solutions

west bridgewater streetleigh, lancashire

WN7 4HBunited kingdom

tel: +44 (0) 1942 265500 fax: +44 (0) 1942 265576

L i t e r a t u r e R e f : s t r u c t u r e d c a b l i n g s y s t e m s 0 3 / 1 3

The information contained in this document is valid and correct at the time of

issue. However, we reserve the right to modify details without notice in the light of

subsequent Standard / Specification changes and ongoing technical developments.

© Brand-Rex Limited 2013