submittal a 0 n dch/aa 3djh 1 of 2 samsung series, :doo

2
Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL A-0-N$DCH/AA www.SamsungHVAC.com 888-699-6067 3DJH 1 of 2 Samsung )-0 Series, :DOO 0RXQWHG (YDSRUDWRU SHA-)-0-06202018 High-voltage terminal block temperature sensor to disable unit in the event overheating of power connection. • Triangle design to provide optimal airflow in and out of the unit. • Refrigerant pipes, drain pipe, high voltage, and low voltage shall be accessible from the bottom of the unit to provide simplified installation and service. • Refrigerant and drain pipe direction can be applied to exit the right, left, bottom, or back sides of the indoor unit. • The drain outlet hose can connect to the left (standard) or right side of the drain pain to provide flexibility during installation. • The indoor unit shall be powered by the outdoor unit. Construction HIPS chassis certified to UL94 V0 with galvanized steel mounting bracket Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Indoor Fan Indoor fan is a single, antibacterial, crossflow type Three fan speed settings and auto setting Motorized vertical-swing (up/down) louver Controls Control signal shall be a DDC type signal Interconnect control wire between outdoor and indoor shall be 16AWG X 2 shielded The indoor unit shall ship with a wireless controller as standard. Optional wired controller options available Controls shall integrate with a BMS system The system shall integrate with the Samsung Controls Solution. Compatibility Will only operate with Samsung outdoor unit model numbers: AJ030MCS4CH/AA, AJ036JCJ5CH/AA. Nominal cooling capacities are based on: Indoor temperature: 80 ͼF DB, 67ͼF WB. Outdoor temperature: 95ͼF DB, 75ͼF WB. Nominal heating capacities are based on: Indoor temperature: 70 ͼF DB, 60ͼF WB. Outdoor temperature: 47ͼF DB, 43ͼF WB. Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Cooling (Btu/h) 22,000 Heating (Btu/h) 25,500 Condensate Pints/Hour 6.5 1 / 208-230 / 60 0.4 Crossflow (1) Type BLDC (1) FLA / Output 0.12A / 27 W Airflow CFM (UL) L/M/H 425 / 495 / 635 R410A Electronic Expansion Valve (at outdoor unit) Liquid (flare) Inches 1/4 Suction (flare) Inches 5/8 Drain Inches ID 11/16" hose W X H X D Inches 41 15/16 X 11 7/8 X 11 9/16 Weight lbs. 31.1 Sound Level L / H dB 25 / 43 DB61-00204A ASP-MO-UNIV 110-250 Premium ¹ AR-WRP2 Standard ² AR-WRS02 25' - ILS2509 50' - ILS5009 ETL (UL 1995) Safety Certifications ¹ AR-WRP2 includes MWR-WE13 wired controller with scheduling, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A). ² AR-WRS02 includes MWR-WH02 wired controller, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A). Specifications Accessories Wireless Controller Holder Condensate Pump Wired Remote Controller Line sets - insulated and flared, interconnect cables included Piping Connections Unit Dimensions Refrigerant Type Control Method Fan Type Motor Performance Nominal Capacity Power Voltage (ø/V/Hz) Nominal Running Current (A) © 2018 Samsung HVAC

Upload: others

Post on 31-Jan-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Job Name LocationPurchaser EngineerSubmitted to Reference Approval ConstructionUnit Designation Schedule #

SUBMITTAL A 0 N DCH/AA

www.SamsungHVAC.com 888-699-6067

1 of 2

Samsung Series,

SHA- -06202018

• High-voltage terminal block temperature sensor to disable unit inthe event overheating of power connection.

• Triangle design to provide optimal airflow in and out of the unit.

• Refrigerant pipes, drain pipe, high voltage, and low voltage shallbe accessible from the bottom of the unit to provide simplified installation and service.

• Refrigerant and drain pipe direction can be applied to exit the right,left, bottom, or back sides of the indoor unit.

• The drain outlet hose can connect to the left (standard) or rightside of the drain pain to provide flexibility during installation.

• The indoor unit shall be powered by the outdoor unit.

ConstructionHIPS chassis certified to UL94 V0 with galvanized steel mountingbracket

Heat ExchangerThe heat exchanger shall be mechanically bonded fin to copper tube

Indoor FanIndoor fan is a single, antibacterial, crossflow type

Three fan speed settings and auto setting

Motorized vertical-swing (up/down) louver

ControlsControl signal shall be a DDC type signal

Interconnect control wire between outdoor and indoor shall be 16AWG X 2 shielded

The indoor unit shall ship with a wireless controller as standard.

Optional wired controller options available

Controls shall integrate with a BMS system

The system shall integrate with the Samsung Controls Solution.

CompatibilityWill only operate with Samsung outdoor unit model numbers: AJ030MCS4CH/AA, AJ036JCJ5CH/AA.

Nominal cooling capacities are based on: Indoor temperature: 80 F DB, 67 F WB. Outdoor temperature: 95 F DB, 75 F WB.

Nominal heating capacities are based on: Indoor temperature: 70 F DB, 60 F WB. Outdoor temperature: 47 F DB, 43 F WB.

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.

Cooling (Btu/h) 22,000

Heating (Btu/h) 25,500

Condensate Pints/Hour 6.5

1 / 208-230 / 60

0.4

Crossflow (1)

Type BLDC (1)

FLA / Output 0.12A / 27 W

Airflow CFM (UL) L/M/H 425 / 495 / 635

R410AElectronic Expansion Valve

(at outdoor unit)

Liquid (flare) Inches 1/4

Suction (flare) Inches 5/8

Drain Inches ID 11/16" hose

W X H X D Inches 41 15/16 X 11 7/8 X 11 9/16

Weight lbs. 31.1

Sound Level L / H dB 25 / 43

DB61-00204A

ASP-MO-UNIV 110-250

Premium ¹ AR-WRP2

Standard ² AR-WRS02

25' - ILS2509

50' - ILS5009

ETL (UL 1995)Safety Certifications¹ AR-WRP2 includes MWR-WE13 wired controller with scheduling, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A). ² AR-WRS02 includes MWR-WH02 wired controller, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A).

Specifications

Accessories

Wireless Controller Holder

Condensate Pump

Wired Remote Controller

Line sets - insulated and flared, interconnect cables included

Piping Connections

Unit Dimensions

RefrigerantType

Control Method

Fan

Type

Motor

PerformanceNominal Capacity

PowerVoltage (ø/V/Hz)

Nominal Running Current (A)

© 2018 Samsung HVAC

www.SamsungHVAC.com

SUBMITTAL A 0 N DCH/AAPage 2 of 2

Samsung Series,

No. Name Description

123456

Liquid Pipe ConnectionGas Pipe ConnectionDrain Pipe ConnectionConduit for Power & Communication WiringAir Inlet GrilleAir Outlet Louver

Ø 1/4" FlareØ Flare

ID 1 "---

A B C D

1 " 4 " " 1 "

For reference only. Always refer to installation manual for complete details.

Minimum clearance from walls and ceiling

(back of unit)

Drain/pipe hole(Ø 2 1/2")

B

A D

C

Drain/pipe hole(Ø 2 1/2")