submittal aj0 txj5ch/aa (jxh48j5 page 1 of 5 samsung … · 2021. 1. 27. · 888-699-6067 page 3 of...

5
Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AJ048TXJ5CH/AA (JXH48J5T) Page 1 of 5 Samsung FJM Series, 5 Port Condensing Unit © 2020 Samsung HVAC SHA-FJM-04132020 888-699-6067 www.SamsungHVAC.com &RPSDWLELOLW\ Will only operate with Samsung evaporator model numbers: AR**TSFABWKNCV (RNS**ABT): 7,000 - 24,000 Btu/h models AR**TSFYBWKNCV (RNS**YBT): 7,000 - 24,000 Btu/h models AJ***TNNDCH/AA (JNH**NDT): 9,000 - 18,000 Btu/h models AJ***TNLDCH/AA (JNH**LDT): 9,000 - 18,000 Btu/h models AJ***TNJDCH/AA (JNH**JDT): 9,000 - 18,000 Btu/h models Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Auto or manual addressing of indoor units The outdoor unit shall supply power individually to the indoor units via 14 AWG X 3 power wire Soft-start to reduce current demand during compressor start Auto-restart after power loss Available maximum current setting option to reduce maximum operating current. Construction The outdoorunit shall be galvanized steel with abaked on powder coated finish for durability Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Controls Control signal shall be a DDC type signal Interconnect control wire between outdoor and indoor units shall be 16AWG X 2 The system shall integrate with the Samsung Controls Solution without the use of an interface module. Refrigerant System The refrigerant shall be R410A The compressor shall be hermetically sealed, inverter controlled, Twin BLDC Rotary Refrigerant flow shall be controlled by 5 separate electronic expansion valves at outdoor unit * Certified in accordance with the AHRI Unitary Small Air-Source Heat Pumps (USHP) Certification Program which is based on the latest edition of AHRI Standard 210/240. Refer to www.AHRIdirectory.org for current reference numbers. Warranty Power Voltage (ø/V/Hz) 1 / 208-230 / 60 Rated Current (amps) 1 Cooling (low / std. / max.) 2.9 / 21.4 / 22.7 Heating (low / std. / max.) 2.2 / 18.1 / 23.3 Max. Breaker Amps 40 Minimum Circuit Ampacity (A) 37.0 Dimensions W X H X D Inches 37 X 47 5/8 X 13 Weight lbs. 192.9 Heating (Max.) dB (A) 55 Cooling (Max.) dB (A) 52 Noise Level Operating Temperatures Cooling 14 ~ 114.8°F (-5 ~ 46.0°C) Heating 5 ~75°F (-15 ~ 24.0°C) Pipe Connections High Side 1/4" X 5 Low Side (suction) 3/8" X 2 + 1/2" X 3 Maximum Individual Line Set Length 82 ft Maximum Line Set Length (total) 230 ft Maximum Vertical Separation Outdoor to Indoor 49 ft Highest to Lowest Indoor 25 ft Included Pipe Adapter 3 - 1/2" X 3/8", 2 - 1/2" X 5/8" Condenser Fan Motor BLDC With Propeller Fan (1) Output Watts / FLA 125 x 2 / 1.28 CFM 3,885 Compressor Type Twin BLDC Rotary Inverter RLA Amps 25.6 Heat Exchanger Type Aluminum Fin - Copper Tube Rows 2 Refrigerant Type R410A Control Method Electronic Expansion Valve Factory Charge 134.0 oz Charged for 164 ft Additional Refrigerant 0.22 oz/ft over 164 ft Ducted 205291860 10 Years compressor, 10 year parts, 1 year limited labor (registration required) Certifications Safety ETL (UL 1995) AHRI Certification Number Non-Ducted 205275703 Mixed 205421132 Accessories Wall Bracket CKN-250 1 Rated current is based on highest combination ratio of non-ducted indoor units. System can be set up as heating/cooling, cooling only, or heating only via outdoor unit option setting. System energy consumption can be viewed using Samsung SmartThings mobile app (not revenue grade, for reference only). Performance* Capacity (standard / max.) Cooling (Btu/h) 47,000 / 48,200 Heating (Btu/h) 48,500 / 53,600 Minimum Cooling Capacity (Btu/h) 8,500 Minimum Heating Capacity (Btu/h) 7,000 SEER (Ducted / Mixed / Non-ducted) 16.0 / 17.85 / 19.7 EER (Ducted / Mixed / Non-ducted) 8.6 / 9.55 / 10.5 HSPF (Ducted / Mixed / Non-ducted) 9.2 / 9.75 / 10.3 JXH48J5T Model AJ048TXJ5CH/AA US Code Model Number

Upload: others

Post on 06-Feb-2021

38 views

Category:

Documents


0 download

TRANSCRIPT

  • Job Name LocationPurchaser EngineerSubmitted to Reference Approval ConstructionUnit Designation Schedule #

    SUBMITTAL AJ048TXJ5CH/AA (JXH48J5T) Page 1 of 5Samsung FJM Series, 5 Port Condensing Unit

    © 2020 Samsung HVAC SHA-FJM-04132020 888-699-6067 www.SamsungHVAC.com

    Will only operate with Samsung evaporator model numbers: AR**TSFABWKNCV (RNS**ABT): 7,000 - 24,000 Btu/h models AR**TSFYBWKNCV (RNS**YBT): 7,000 - 24,000 Btu/h models AJ***TNNDCH/AA (JNH**NDT): 9,000 - 18,000 Btu/h models AJ***TNLDCH/AA (JNH**LDT): 9,000 - 18,000 Btu/h models AJ***TNJDCH/AA (JNH**JDT): 9,000 - 18,000 Btu/h models

    Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.

    • Auto or manual addressing of indoor units

    • The outdoor unit shall supply power individually to the indoor units via 14 AWG X 3 power wire

    • Soft-start to reduce current demand during compressor start

    • Auto-restart after power loss

    • Available maximum current setting option to reduce maximumoperating current.

    ConstructionThe outdoorunit shall be galvanized steel with abaked on powdercoated finish for durability

    Heat ExchangerThe heat exchanger shall be mechanically bonded fin to copper tube

    ControlsControl signal shall be a DDC type signal

    Interconnect control wire between outdoor and indoor units shall be 16AWG X 2

    The system shall integrate with the Samsung Controls Solutionwithout the use of an interface module.

    Refrigerant SystemThe refrigerant shall be R410A

    The compressor shall be hermetically sealed, inverter controlled,Twin BLDC Rotary

    Refrigerant flow shall be controlled by 5 separate electronic expansion valves at outdoor unit

    * Certified in accordance with the AHRI Unitary Small Air-Source Heat Pumps (USHP) Certification Program which is based on the latest edition of AHRI Standard 210/240. Refer to www.AHRIdirectory.org for current reference numbers.

    Warranty

    Power

    Voltage (ø/V/Hz) 1 / 208-230 / 60

    Rated Current (amps) 1Cooling (low / std. / max.) 2.9 / 21.4 / 22.7Heating (low / std. / max.) 2.2 / 18.1 / 23.3

    Max. Breaker Amps 40Minimum Circuit Ampacity (A) 37.0

    DimensionsW X H X D Inches 37 X 47 5/8 X 13Weight lbs. 192.9

    Heating (Max.) dB (A) 55Cooling (Max.) dB (A) 52Noise Level

    Operating Temperatures

    Cooling 14 ~ 114.8°F (-5 ~ 46.0°C)Heating 5 ~75°F (-15 ~ 24.0°C)

    Pipe Connections

    High Side 1/4" X 5Low Side (suction) 3/8" X 2 + 1/2" X 3Maximum Individual Line Set Length 82 ftMaximum Line Set Length (total) 230 ft

    Maximum Vertical Separation

    Outdoor to Indoor 49 ftHighest to Lowest Indoor 25 ft

    Included Pipe Adapter 3 - 1/2" X 3/8", 2 - 1/2" X 5/8"

    Condenser FanMotor BLDC With Propeller Fan (1)

    OutputWatts / FLA 125 x 2 / 1.28CFM 3,885

    CompressorType Twin BLDC Rotary InverterRLA Amps 25.6

    Heat ExchangerType Aluminum Fin - Copper Tube

    Rows 2

    Refrigerant

    Type R410AControl Method Electronic Expansion ValveFactory Charge 134.0 ozCharged for 164 ftAdditional Refrigerant 0.22 oz/ft over 164 ft

    Ducted 205291860

    10 Years compressor, 10 year parts, 1 year limited labor (registration required)

    Certifications

    Safety ETL (UL 1995)

    AHRI Certification Number

    Non-Ducted 205275703

    Mixed 205421132

    Accessories Wall Bracket CKN-250

    1 Rated current is based on highest combination ratio of non-ducted indoor units.

    • System can be set up as heating/cooling, cooling only, or heatingonly via outdoor unit option setting.

    • System energy consumption can be viewed using SamsungSmartThings mobile app (not revenue grade, for reference only).

    Performance*

    Capacity (standard / max.)

    Cooling (Btu/h) 47,000 / 48,200Heating (Btu/h) 48,500 / 53,600

    Minimum Cooling Capacity (Btu/h) 8,500Minimum Heating Capacity (Btu/h) 7,000SEER (Ducted / Mixed / Non-ducted) 16.0 / 17.85 / 19.7EER (Ducted / Mixed / Non-ducted) 8.6 / 9.55 / 10.5HSPF (Ducted / Mixed / Non-ducted) 9.2 / 9.75 / 10.3

    JXH48J5TModel

    AJ048TXJ5CH/AAUS CodeModel Number

  • 888-699-6067 www.SamsungHVAC.com

    Page 2 of 5

    Samsung FJM, 5 Port Condensing Unit Dimensional drawing

    SUBMITTAL AJ048TXJ5CH/AA (JXH48J5T)

    TOP

    FRONT RIGHTLEFT

    BOTTOM

    BACK

    12 3/8"

    12 1

    5/16

    "

    14 3

    /16"

    15 1

    /8"

    37"

    46 5

    /8"

    47 5

    /8"

    1" 40 3/4" 5 1/2" 1 5/8"

    2 1/16"

    18 1

    /16"

    15 1

    /2"

    12 1

    5/16

    "

    10 3

    /8"

    7 13

    /16"

    1 1/8"

    1 9/16"

    6 9/

    16"

    9 1/

    8"

    11 9

    /16"

    14 3

    /16"

    16 3

    /4"

    3 3/

    4"7

    3/16

    "

    8 5/8" 15 7/16" 1 3/

    16"

    5

    1

    2

    3

    4

    Power and Communication Wiring Conduit

    No. Name Description

    1 Refrigerant suction pipes ø3/8" x 2, ø1/2" x 3

    2 Refrigerant liquid pipes ø1/4" x 5

    3 Service Valve (suction) 5/8"4 Service Valve (liquid) 3/8"

    5 Drain holes Connection with provided drain fitting

  • 888-699-6067 www.SamsungHVAC.com

    Page 3 of 5

    Samsung FJM, 5 Port Condensing Unit Indoor unit connection options

    SUBMITTAL AJ048TXJ5CH/AA (JXH48J5T)

    Must have a minimum of 2 indoor units connected. Will only operate with Samsung evaporator model numbers listed below:

    AR**TSFABWKNCV (RNS**ABT): 7,000 - 24,000 Btu/h models AR**TSFYBWKNCV (RNS**YBT): 7,000 - 24,000 Btu/h models AJ***TNNDCH/AA (JNH**NDT): 9,000 - 18,000 Btu/h models AJ***TNLDCH/AA (JNH**LDT): 9,000 - 18,000 Btu/h models AJ***TNJDCH/AA (JNH**JDT): 9,000 - 18,000 Btu/h models

    A B C D E A B C D E7,000 7,000 7,000 7,000 7,0007,000 9,000 7,000 7,000 9,0007,000 12,000 7,000 7,000 12,0007,000 15,000 7,000 7,000 15,0007,000 18,000 7,000 7,000 18,0007,000 24,000 7,000 7,000 24,0009,000 9,000 7,000 9,000 9,0009,000 12,000 7,000 9,000 12,0009,000 15,000 7,000 9,000 15,0009,000 18,000 7,000 9,000 18,0009,000 24,000 7,000 9,000 24,00012,000 12,000 7,000 12,000 12,00012,000 15,000 7,000 12,000 15,00012,000 18,000 7,000 12,000 18,00012,000 24,000 7,000 12,000 24,00015,000 15,000 7,000 15,000 15,00015,000 18,000 7,000 15,000 18,00015,000 24,000 7,000 15,000 24,00018,000 18,000 7,000 18,000 18,00018,000 24,000 7,000 18,000 24,00024,000 24,000 7,000 24,000 24,000

    9,000 9,000 9,0009,000 9,000 12,0009,000 9,000 15,0009,000 9,000 18,0009,000 9,000 24,0009,000 12,000 12,0009,000 12,000 15,0009,000 12,000 18,0009,000 12,000 24,0009,000 15,000 15,0009,000 15,000 18,0009,000 15,000 24,0009,000 18,000 18,0009,000 18,000 24,0009,000 24,000 24,00012,000 12,000 12,00012,000 12,000 15,00012,000 12,000 18,00012,000 12,000 24,00012,000 15,000 15,00012,000 15,000 18,00012,000 15,000 24,00012,000 18,000 18,00012,000 18,000 24,00015,000 15,000 15,00015,000 15,000 18,00015,000 15,000 24,00015,000 18,000 18,00015,000 18,000 24,00018,000 18,000 18,000

    Indoor Unit Capacity (Btu/h)

    3 Indoor Units

    Indoor Unit Capacity (Btu/h)

    2 Indoor Units

  • 888-699-6067 www.SamsungHVAC.com

    Page 4 of 5

    Samsung FJM, 5 Port Condensing Unit Indoor unit connection options

    SUBMITTAL AJ048TXJ5CH/AA (JXH48J5T)

    Must have a minimum of 2 indoor units connected. Will only operate with Samsung evaporator model numbers listed below:

    AR**TSFABWKNCV (RNS**ABT): 7,000 - 24,000 Btu/h models AR**TSFYBWKNCV (RNS**YBT): 7,000 - 24,000 Btu/h models AJ***TNNDCH/AA (JNH**NDT): 9,000 - 18,000 Btu/h models AJ***TNLDCH/AA (JNH**LDT): 9,000 - 18,000 Btu/h models AJ***TNJDCH/AA (JNH**JDT): 9,000 - 18,000 Btu/h models

    BA C D E A B C D E7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,0007,000 7,000 7,000 9,000 7,000 7,000 7,000 7,000 9,0007,000 7,000 7,000 12,000 7,000 7,000 7,000 7,000 12,0007,000 7,000 7,000 15,000 7,000 7,000 7,000 7,000 15,0007,000 7,000 7,000 18,000 7,000 7,000 7,000 7,000 18,0007,000 7,000 7,000 24,000 7,000 7,000 7,000 7,000 24,0007,000 7,000 9,000 9,000 7,000 7,000 7,000 9,000 9,0007,000 7,000 9,000 12,000 7,000 7,000 7,000 9,000 12,0007,000 7,000 9,000 15,000 7,000 7,000 7,000 9,000 15,0007,000 7,000 9,000 18,000 7,000 7,000 7,000 9,000 18,0007,000 7,000 9,000 24,000 7,000 7,000 7,000 9,000 24,0007,000 7,000 12,000 12,000 7,000 7,000 7,000 12,000 12,0007,000 7,000 12,000 15,000 7,000 7,000 7,000 12,000 15,0007,000 7,000 12,000 18,000 7,000 7,000 7,000 12,000 18,0007,000 7,000 12,000 24,000 7,000 7,000 7,000 12,000 24,0007,000 7,000 15,000 15,000 7,000 7,000 7,000 15,000 15,0007,000 7,000 15,000 18,000 7,000 7,000 7,000 15,000 18,0007,000 7,000 15,000 24,000 7,000 7,000 7,000 18,000 18,0007,000 7,000 18,000 18,000 7,000 7,000 9,000 9,000 9,0007,000 7,000 18,000 24,000 7,000 7,000 9,000 9,000 12,0007,000 9,000 9,000 9,000 7,000 7,000 9,000 9,000 15,0007,000 9,000 9,000 12,000 7,000 7,000 9,000 9,000 18,0007,000 9,000 9,000 15,000 7,000 7,000 9,000 9,000 24,0007,000 9,000 9,000 18,000 7,000 7,000 9,000 12,000 12,0007,000 9,000 9,000 24,000 7,000 7,000 9,000 12,000 15,0007,000 9,000 12,000 12,000 7,000 7,000 9,000 12,000 18,0007,000 9,000 12,000 15,000 7,000 7,000 9,000 15,000 15,0007,000 9,000 12,000 18,000 7,000 7,000 9,000 15,000 18,0007,000 9,000 12,000 24,000 7,000 7,000 12,000 12,000 12,0007,000 9,000 15,000 15,000 7,000 7,000 12,000 12,000 15,0007,000 9,000 15,000 18,000 7,000 7,000 12,000 12,000 18,0007,000 9,000 15,000 24,000 7,000 7,000 12,000 15,000 15,0007,000 9,000 18,000 18,000 7,000 9,000 9,000 9,000 9,0007,000 12,000 12,000 12,000 7,000 9,000 9,000 9,000 12,0007,000 12,000 12,000 15,000 7,000 9,000 9,000 9,000 15,0007,000 12,000 12,000 18,000 7,000 9,000 9,000 9,000 18,0007,000 12,000 12,000 24,000 7,000 9,000 9,000 12,000 12,0007,000 12,000 15,000 15,000 7,000 9,000 9,000 12,000 15,0007,000 12,000 15,000 18,000 7,000 9,000 9,000 12,000 18,0007,000 12,000 18,000 18,000 7,000 9,000 9,000 15,000 15,0007,000 15,000 15,000 15,000 7,000 9,000 12,000 12,000 12,0007,000 15,000 15,000 18,000 7,000 9,000 12,000 12,000 15,0009,000 9,000 9,000 9,000 7,000 12,000 12,000 12,000 12,0009,000 9,000 9,000 12,000 9,000 9,000 9,000 9,000 9,0009,000 9,000 9,000 15,000 9,000 9,000 9,000 9,000 12,0009,000 9,000 9,000 18,000 9,000 9,000 9,000 9,000 15,0009,000 9,000 9,000 24,000 9,000 9,000 9,000 9,000 18,0009,000 9,000 12,000 12,000 9,000 9,000 9,000 12,000 12,0009,000 9,000 12,000 15,000 9,000 9,000 9,000 12,000 15,0009,000 9,000 12,000 18,000 9,000 9,000 9,000 12,000 18,0009,000 9,000 12,000 24,000 9,000 9,000 9,000 15,000 15,0009,000 9,000 15,000 15,000 9,000 9,000 12,000 12,000 12,0009,000 9,000 15,000 18,000 9,000 9,000 12,000 12,000 15,0009,000 9,000 15,000 24,000 9,000 12,000 12,000 12,000 12,0009,000 9,000 18,000 18,0009,000 12,000 12,000 12,0009,000 12,000 12,000 15,0009,000 12,000 12,000 18,0009,000 12,000 12,000 24,0009,000 12,000 15,000 15,0009,000 12,000 15,000 18,0009,000 12,000 18,000 18,0009,000 15,000 15,000 15,0009,000 15,000 15,000 18,00012,000 12,000 12,000 12,00012,000 12,000 12,000 15,00012,000 12,000 12,000 18,00012,000 12,000 15,000 15,00012,000 12,000 15,000 18,00012,000 15,000 15,000 15,000

    Indoor Unit Capacity (Btu/h)

    5 Indoor Units

    Indoor Unit Capacity (Btu/h)

    4 Indoor Units

  • 888-699-6067 www.SamsungHVAC.com

    Page 5 of 5

    Samsung FJM, 5 Port Condensing Unit Wiring example

    SUBMITTAL AJ048TXJ5CH/AA (JXH48J5T)

    Basic Wire Connection Diagram

    This simple wiring diagram is for reference only. Please refer to installation manuals for full details and requirements.

    NL 1(L) 2(N) 1(L) 2(N)

    F11(L) 2(N) F2 1(L) 2(N) F1 F12(N) 1(L) 1(L) 2(N) F1F2

    1 2 F1 F2 F1 F21 2

    21

    F2

    1 2 F1 F2

    F1 F2

    F2

    F1 F2

    F1 F2

    1 2

    1 2

    B C B CB C B C

    A

    1(L) 2(N) F1 F2

    F1 F2

    F1 F2

    1 2

    B C

    F1 F2 F1 F2

    F1 F2 F1 F2

    L N

    21

    terminal

    212 21

    A-unit B-unit C-unit D-unit E-unit

    Indoor unit

    Earth

    Earth terminal

    Outdoor unit

    Main power supply cable

    Power cable to indoor units

    Communication cable to indoor units

    Earth terminal

    Earth terminal

    Earth terminal

    Earth terminal

    Earth terminal

    Earth terminal

    Earth terminal

    Earth terminal

    Earth terminal

    1

    Outdoor unit

    Job Name: Location: Purchaser: Engineer: Submitted to: Check Box1: OffCheck Box2: OffCheck Box3: OffUnit Designation: Schedule: Check Box5: Off