subsea corrosion experiences - marine renewables … corrosion experiences . ... introduction 2. dnv...

26
Material durability of Cables and Moorings Jan Kenkhuis – Principal Engineer Mooring & Subsea Subsea Corrosion Experiences

Upload: truongnhan

Post on 12-Mar-2018

238 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Material durability of Cables and Moorings

Jan Kenkhuis – Principal Engineer Mooring & Subsea

Subsea Corrosion Experiences

Page 2: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Workshop Front End Engineering

Agenda of this Presentation

1. Introduction 2. DNV code

Subsea Facilities 3. Umbilical's Oil & Gas 4. Moorings Oil & Gas 5. Bluetec Texel practice 6. Engineering 7. Conclusion 8. Questions

2

Page 3: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

3

Page 4: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Story of the US Navy Littoral Combat Ship

Aim Easy to Maintain over their lifespan

http://www.nace.org/CORROSION-FAILURE-LCS-2-USS-Independence-Naval-Ship-Engine-Corrosion.aspx

Introduction- World known Example of 2002

Ships were made of Aluminium with • First ship suffered galvanic corrosion (2003) • Second ship crack through the hull (2013)

Cause of Failure ---Design Flaws (2014) • Corrosion concentrated in the ships propulsion system

where steel impeller housing came in contact with the aluminium vessel (Nov 2013)

• The specification lacked the requirement for a Cathodic protection system

• 2 dissimilar metals come into electrical contact • Electrical continuity not established

Page 5: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

DNV-GL code – Subsea Facilities( 2014)

Oil & Gas Technology Developments ; Incidents and Future Trends

5

• Technology - Historical trends, future trends and developments

• Integrity management (from design to operation). • Degradation mechanisms and failure modes. • Inspection, maintenance and monitoring

methodologies. • Recommendations for improvements and knowledge

sharing.

The threat of corrosion corrosion is a material degradation; depends on the exposed environment and the material or a combination of materials in question

Page 6: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

DNV-GL code – Degradation mechanism

The threat “material degradation” mechanism occurs either: Abrupt degradation

brittle facture of ceramics; glass; fasteners

Slow over time

CO2-corrosion of alloy steel and fatigue;

ageing of elastomers;

loss of spring capacity

6

Page 7: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Bluewater SPM System (2008)

7

Page 8: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Umbilical SUTU example

8

At time of installation in 2008 At time of repair in 2009

Page 9: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

SUTU after recovering

Open SUTU Hydraulic connectors

9

Page 10: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Cause of the rapid corrosion

• No electrical continuity guaranteed between connectors and bulkhead plate.

• Connectors supplied from 1.4418 stainless grade. Equals to 304 grade

• The specification asked for 316L grade • Concerns raised about the uncertainty

of the isolation between SUTU and PLEM

10

Page 11: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

2nd example Bluewater Haewene Brim

11

Page 12: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Non Sheathed Spiral Strand Wire

Bird cage detection close up picture

12

Page 13: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Cathodic Protection on Sockets

Anode after 5 years

13

Anode new

Page 14: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Cathodic protection of chain stopper

Orkot bushes to achieve electrical discontinuity

chain stoppers with CP system

14

Page 15: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Bluewater Texel Project Experiences

Water depth= 30m

Page 16: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

BTT in Operation

16

BTT platform Oct 2015

Page 17: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

1. Position joining shackle nylon - chain

2. Umbilical bottom frame

3. Shape free spanning umbilical

Side view mooring system

5. Umbilical routing bottom connector - shore

4. Position chain routing and anchors (4x)

Page 18: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Visual Inspections

18

Mooring Lines: after 0.5 years Mooring Lines: prior installation

Page 19: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

BTT underwater, non-coated

19

Page 20: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

BTT floater out of the water

20

Before cleaning

After cleaning

Page 21: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

BTT Cathodic Protection

21

Page 22: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Lifecycle of a Development Project

Operate

Detailed Design

Fab / Cons. Documents

Procurement

Proposal &

Tender Preparation

Concept Developmen

t

<---- -------------------------------Project Initiation [FEED]----------------------------->

Conceptual and partly detailed Floater Layout

Contract Award

Project Definition

Operation & maintenance

Definition

Engineering Design

Site Preparation, anchoring, erection or hook-up,

Instrument, Electrical Installation

Assembly & Offshore Installation

Material Acquisitio

n

Fabrication

Fabrication

Start-up Commissionin

g Handover

Checkout and Pre-Commissioning

Commissioning & Handover

Page 23: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Development Risk Assessment

• The first step in assessing feasibility is the risk assessment review result for:

• Manufacturing • Assembly on site • Foundation Installation • Mooring spread pay-out • Hook-up • Cable Installation • Operation • Day to Day maintenance

Page 24: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Integrity Management of Subsea Systems

24

ESTABLISH INTEGRITY MAINTAIN INTEGRITY Concept, design and Construction (incl. pre-commissioning)

Operations (incl. Commissioning)

INTEGRITY MANAGEMENT PROCESS Risk Assessment and Integrity Management (IM) Planning

Inspection Monitoring and Testing

Integrity Assessment

Mitigation, intervention and repair

Page 25: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

25

Based on sound engineering practice the following can be concluded: 1. The mooring or cable design spec should included external coating protection

combined with CP systems.// electrical continuity etc. 2. Request verification of a corrosion expert as part of risk assessment program 3. The materials provided by supplier should be traceable [MRB] 4. Acceptance test of batches of components could be included

to check on suitability for subsea applications 5. Often if the proposed components are mature and proven this has an advantage 6. Avoid damage to the coating ( sheathing) as much as possible in installation stage. 7. Execute electrical continuity checks prior lowering overboard. 8. Use sheathed steel wires only ( offers an extra of 5-8 years of service life) 9. Develop in engineering stage an Subsea Integrity management plan.

Page 26: Subsea Corrosion Experiences - Marine Renewables … Corrosion Experiences . ... Introduction 2. DNV code Subsea Facilities 3. Umbilical's Oil & Gas 4. ... Equals to 304 grade

Thank you! Questions?