summit matsu chillers 2013 product brochure
DESCRIPTION
Our full range of world class chillers. Designing, engineering and building the most reliable and highest quality chillers. Summit Matsu Chillers. Your Industry Expert.TRANSCRIPT
1
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers June 2013 standard chiller range (please contact us for any non-standard requirement on 1300 244 553) Table of Contents:
CHILLER RANGE: UMWC-8-1KW TO 3KW CADET SERIES 2
CHILLER RANGE: UMWC-8-1.0KW TO 6KW 3
CHILLER RANGE: UMWC-8-7.0KW TO 12KW 5
CHILLER RANGE: UMWC-8-18KW TO 36KW 6
CHILLER RANGE: UMWC-8-46KW TO 76KW 7
CHILLER RANGE: UMWC-8-85KW TO 130KW 8
CHILLER RANGE: UMWC-7-3KW TO 6KW 9
CHILLER RANGE: UMWC-7-7KW TO 16KW 10
CHILLER RANGE: USDA-7-22KW TO 45KW (CAS17) 11
CHILLER RANGE: USDA-7-55KW TO 85KW (CAS17) 12
CHILLER RANGE: USDA-7-75KW TO 140KW 13
CHILLER PRODUCT: COLD SPA CHILLER 14
CHILLER RANGE: USMC-6-120KW TO 240KW – SCROLL OPTION 15
CHILLER RANGE: USMC-6-220KW TO 300KW – SCREW OPTION 16
CHILLER RANGE: USMC-6-360KW TO 450KW – SCREW OPTION 17
CHILLER RANGE: USMC-6-500KW TO 900KW – SCREW OPTION 18
NOTES: 19
2
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia
Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
Chiller Range: UMWC-8-1kW to 3kW Cadet Series
Key Features (Model) UMWC-8-1 Cadet UMWC-8-1.5 Cadet UMWC-8-2.0 Cadet UMWC-8-3 Cadet
kW Size 1 1.5 2 2.9
Water Supply Temp (◦C) 0 0 0 0
Water Return Temp (◦C) 5 5 5 5
Cabinet
Length (mm) 700 700 700 700
Depth (mm) 455 455 455 455
Height (mm) 475 475 475 475
Shipping Weight (kg) 35 35 35 35
Operating Weight (kg) 41 41 41 41
Cabinet Code Cas 3 Cas 3 Cas 3 Cas 3
Cabinet Finish Painted Painted Painted Painted
Refrigeration
Capacity (KW) 1 1.5 2 2.9
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Coils in Tank Coils in Tank Coils in Tank Coils in Tank
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style Rotary Rotary Rotary Rotary
Number Compressors 1 1 1 1
Comp Capacity Control None None None None
Gas Type R407C R407C R407C R407C
Gas Charge (kg) 1.5 1.7 2 2
Fan Type Axial Axial Axial Axial
Noise Level (dB(A)) 45 45 45 45
Electrical
Power Supply (V/PH/Hz) 230V 50Hz 1Ph 230V 50Hz 1Ph 230V 50Hz 1Ph 230V 50Hz 1Ph
RLA 5.8 7.0 8 10.0
FLA 6.8 7.8 9 12.9
LRA 20.4 23.4 27 38.7
Auto Program Controller Yes Yes Yes Yes
Controller Type Digital Thermostat Digital Thermostat Digital Thermostat Digital Thermostat
Comp Time Delay Yes Yes Yes Yes
Auto Restart Yes Yes Yes Yes
External Controls None None None None
Control Stages 1 1 1 1
Water
Pump In-built Yes Yes Yes Yes
Water Flow (l/s) 0.02 0.05 0.1 0.12
Rated Pump Head (min) 5M / 50kPa 5M / 50kPa 5M / 50kPa 5M / 50kPa
Tank and Water make up Manual make-up Manual make-up Manual make-up Manual make-up
Water Tank 6L 6L 6L 6L
Prevention from freezing Yes Yes Yes Yes
Pipe Size mm (supply) 25 25 25 25
Pipe Size mm (return) 25 25 25 25
Internal Bypass No No No No
Include Flow Switch No No No No
3
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Chiller Range: UMWC-8-1.0kW to 6kW
Key Features (Model) UMWC-8-1.0 UMWC-8-2.0 UMWC-8-3 UMWC-8-6
kW Size 1.0 2.0 2.9 5.8
Water Supply Temp (◦C) 0 0 0 0
Water Return Temp (◦C) 5 5 5 5
Cabinet
Length (mm) 760 760 760 760
Depth (mm) 600 600 600 600
Height (mm) 1220 1220 1220 1220
Shipping Weight (kg) 69 75 96 98
Operating Weight (kg) 176 187 197 198
Cabinet Code Cas 4 Cas 4 Cas 4 Cas 4
Cabinet Finish Painted Painted Painted Painted
Refrigeration
Capacity (KW) 1.0 2.0 3.0 5.8
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Coils in Tank Coils in Tank Coils in Tank Coils in Tank
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style Rotary Rotary Rotary Rotary
Number Compressors 1 1 1 1
Comp Capacity Control None None None None
Gas Type R407C R407C R407C R407C
Gas Charge (kg) 1.5 2 2 2.5
Fan Type 1 - Axial 1 - Axial 1 - Axial 1 - Axial
Noise Level (dB(A)) 45 45 58 58
Electrical
Power Supply (V/PH/Hz) 230V 50Hz 1Ph 230V 50Hz 1Ph 230V 50Hz 1Ph 230V 50Hz 1Ph
RLA 8.3 10.5 14.4 14.5
FLA 9.4 11.4 15.4 15.6
LRA 38.7 46.2 46.5 61.5
Auto Program Controller Yes Yes Yes Yes
Controller Type Digital
Thermostat Digital
Thermostat Digital
Thermostat Digital
Thermostat
Comp Time Delay Yes Yes Yes Yes
Auto Restart Yes Yes Yes Yes
External Controls None None None None
Control Stages 1 1 1 1
Water
Pump In-built Yes Yes Yes Yes
Water Flow (l/s) 0.1 + bypass 0.14 + bypass 0.17 + bypass 0.28 + bypass
Rated Pump Head (min) 10M / 1bar 10M / 1bar 10M / 1bar 10M / 1bar
Tank and Water make up Yes Yes Yes Yes
Water Tank 60./L 60./L 60./L 60./L
Prevention from freezing Yes Yes Yes Yes
Pipe Size mm (supply) 25 25 25 25
Pipe Size mm (return) 25 25 25 25
Internal Bypass Yes - Manual Yes - Manual Yes - Manual Yes - Manual
Include Flow Switch No No No No
4
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia
Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
5
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Chiller Range: UMWC-8-7.0kW to 12kW
Key Features (Model) UMWC-8-7.0 UMWC-8-9 UMWC-8-12
kW Size 7.3 9 12
Water Supply Temp (◦C) 0 0 0
Water Return Temp (◦C) 5 5 5
Cabinet
Length (mm) 990 990 990
Depth (mm) 830 830 830
Height (mm) 1220 1220 1220
Shipping Weight (kg) 135 155 165
Operating Weight (kg) 225 245 255
Cabinet Code Cas 5 Cas 5 Cas 5
Cabinet Finish Painted Painted Painted
Refrigeration
Capacity (KW) 7.3 9 12
Condenser Design Air Cooled
Aluminium Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Coils in Tank Coils in Tank Coils in Tank
Unit Operation Cooling Only Cooling Only Cooling Only
Compressor Style Hermetic
Scroll Hermetic
Scroll Hermetic
Scroll
Number Compressors 1 1 1
Comp Capacity Control None None None
Gas Type R407C R407C R407C
Gas Charge (kg) 3.0 3.5 4
Fan Type 1 - Axial 1 - Axial 1 - Axial
Noise Level (dB(A)) 61 61 63
Electrical
Power Supply (V/PH/Hz) 230V 50Hz
1Ph 230V 50Hz
1Ph 400V 50Hz
3Ph
RLA 17 18 12
FLA 18.1 19.7 13.9
LRA 74.1 102 52.2
Auto Program Controller Yes Yes Yes
Controller Type Digital
Thermostat Digital
Thermostat Digital
Thermostat
Comp Time Delay Yes Yes Yes
Auto Restart Yes Yes Yes
External Controls None None None
Control Stages 1 1 1
Water
Pump In-built Yes Yes Yes
Water Flow (l/s) 0.35 + bypass 0.43 + bypass 0.57 + bypass
Rated Pump Head (min) 10M / 1bar 10M / 1bar 10M / 1bar
Tank and Water make up Yes Yes Yes
Water Tank 120/L 120/L 120/L
Prevention from freezing Yes Yes Yes
Pipe Size mm (supply) 25 25 25
Pipe Size mm (return) 25 25 25
Internal Bypass Yes - Manual Yes - Manual Yes - Manual
Include Flow Switch No No No
6
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia
Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
Chiller Range: UMWC-8-18kW to 36kW
Key Features (Model) UMWC-8-18 UMWC-8-22 UMWC-8-28 UMWC-8-36
kW Size 18 22 28 36
Water Supply Temp (◦C) 0 0 0 0
Water Return Temp (◦C) 5 5 5 5
Cabinet
Length (mm) 1530 1530 1530 1530
Depth (mm) 760 760 760 760
Height (mm) 1850 1850 1850 1850
Shipping Weight (kg) 600 600 650 720
Operating Weight (kg) 1100 1100 1150 1220
Cabinet Code Cas 6 Cas 6 Cas 6 Cas 6
Cabinet Finish Painted Painted Painted Painted
Refrigeration
Capacity (KW) 18 22 27 36
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Coils in Tank Coils in Tank Coils in Tank Coils in Tank
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style Scroll Hermetic
Reciprocating Hermetic
Reciprocating Semi Hermetic
Scroll
Number Compressors 1 1 1 1
Comp Capacity Control None None None None
Gas Type R407C R407C R407C R407C
Gas Charge (kg) 6 6 7 8.5
Fan Type Axial Axial Axial Axial
Noise Level (dB(A)) 55 55 58 58
Electrical
Power Supply (V/PH/Hz) 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
RLA 25 28 34 41
FLA 27.1 32.1 38.1 46.2
LRA 110 150 216 244
Auto Program Controller Yes Yes Yes
Controller Type Micro Processor Micro Processor Micro Processor Micro Processor
Comp Time Delay Yes Yes Yes Yes
Auto Restart Yes Yes Yes Yes
External Controls Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop
Control Stages 1 1 1 1
Water
Pump In-built Yes Yes Yes Yes
Water Flow (l/s) 0.9 + bypass 1.1 + bypass 1.3 + bypass 1.7 + bypass
Rated Pump Head (min) 10M / 1bar 10M / 1bar 10M / 1bar 10M / 1bar
Tank and Water make up Yes Yes Yes Yes
Water Tank 200./L 200./L 200./L 200./L
Prevention from freezing Yes Yes Yes Yes
Pipe Size mm (supply) 32 32 32 32
Pipe Size mm (return) 32 32 32 32
Internal Bypass Yes Yes Yes Yes
Include Flow Switch No No No No
7
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Chiller Range: UMWC-8-46kW to 76kW
Key Features (Model) UMWC-8-46 UMWC-8-56 UMWC-8-66 UMWC-8-76
kW Size 46 56 66 76
Water Supply Temp (◦C) 0 0 0 0
Water Return Temp (◦C) 5 5 5 5
Cabinet
Length (mm) 1485 1485 1485 1485
Depth (mm) 1595 1595 1595 1595
Height (mm) 2075 2075 2075 2075
Shipping Weight (kg) 860 880 950 1000
Operating Weight (kg) 1350 1380 1450 1500
Cabinet Code Cas 7 Cas 7 Cas 7 Cas 7
Cabinet Finish Painted Painted Painted Painted
Refrigeration
Capacity (KW) 46 56 66 76
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Coils in Tank Coils in Tank Coils in Tank Coils in Tank
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style Semi-Hermetic
Scroll Semi-Hermetic Reciprocating
Semi-Hermetic Reciprocating
Semi-Hermetic Reciprocating
Number Compressors 1 1 1 1
Comp Capacity Control Nil Step 50 / 100 Step 66/ 100 Step 66 / 100
Gas Type R407C R407C R407C R407C
Gas Charge (kg) 10 10.5 11 12
Fan Type Axial Axial Axial Axial
Noise Level (dB(A)) 61 63 65 70
Electrical
Power Supply (V/PH/Hz) 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
RLA 35 51 60 74
FLA 55.2 65.2 84.2 102.2
LRA 285 202 225 257
Auto Program Controller Yes Yes Yes Yes
Controller Type Micro Processor Micro Processor Micro Processor Micro Processor
Comp Time Delay Yes Yes Yes Yes
Auto Restart Yes Yes Yes Yes
External Controls Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop
Control Stages 1 2 2 2
Water
Pump In-built Yes Yes Yes Yes
Water Flow (l/s) 2.2 2.8 3.3 3.6
Rated Pump Head (min) 10M / 1bar 10M / 1bar 10M / 1bar 10M / 1bar
Tank and Water make up Yes Yes Yes Yes
Water Tank 500./L 500/L 750./L 750./L
Prevention from freezing Yes Yes Yes Yes
Pipe Size mm (supply) 50 50 50 50
Pipe Size mm (return) 50 50 50 50
Internal Bypass Yes Yes Yes Yes
Include Flow Switch No No No No
8
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia
Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
Chiller Range: UMWC-8-85kW to 130kW
Key Features (Model) UMWC-8-85 UMWC-8-100 UMWC-8-110 UMWC-8-130
kW Size 85 100 110 130
Water Supply Temp (◦C) 0 0 0 0
Water Return Temp (◦C) 5 5 5 5
Cabinet
Length (mm) 3000 3000 3000 3000
Depth (mm) 1595 1595 1595 1595
Height (mm) 2075 2075 2075 2075
Shipping Weight (kg) 1020 1300 1320 1320
Operating Weight (kg) 1520 2050 2070 2150
Cabinet Code Cas 8 Cas 8 Cas 8 Cas 8
Cabinet Finish Painted Painted Painted Painted
Refrigeration
Capacity (KW) 85 100 110 130
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Coils in Tank Coils in Tank Coils in Tank Coils in Tank
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style Screw Screw Screw Screw
Number Compressors 1 1 1 1
Comp Capacity Control Step 50 / 75 / 100 Step 50 / 75 / 100 Step 50 / 75 / 100 Step 50 / 75 / 100
Gas Type R407C R407C R407C R407C
Gas Charge (kg) 20 23 25 30
Fan Type Axial Axial Axial Axial
Noise Level (dB(A)) 78 78 85 85
Electrical
Power Supply (V/PH/Hz) 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
RLA 80 90 96 114
FLA 102.9 114.4 142.2 162.1
LRA 321 351 344 362
Auto Program Controller Yes Yes Yes Yes
Controller Type Micro Processor Micro Processor Micro Processor Micro Processor
Comp Time Delay Yes Yes Yes Yes
Auto Reset Yes Yes Yes Yes
External Controls Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop
Control Stages 3 3 3 3
Water
Pump In-built Yes Yes Yes Yes
Water Flow (l/s) 4.1 + bypass 4.8 + bypass 5.3 + bypass 6.2 + bypass
Rated Pump Head (min) 10M / 1bar 10M / 1bar 10M / 1bar 10M / 1bar
Tank and Water make up Yes Yes Yes Yes
Water Tank 750./L 750/L 1000./L 1000./L
Prevention from freezing Yes Yes Yes Yes
Pipe Size mm (supply) 75 75 75 75
Pipe Size mm (return) 75 75 75 75
Internal Bypass Yes Yes Yes Yes
Include Flow Switch No No No No
9
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Chiller Range: UMWC-7-3kW to 6kW
Key Features (Model) UMWC-7-3.0 UMWC-7-6.0
kW Size 2.9 5.8
Water Supply Temp (◦C) 7 7
Water Return Temp (◦C) 12 12
Cabinet
Length (mm) 760 760
Depth (mm) 600 600
Height (mm) 1220 1220
Shipping Weight (kg) 69 98
Operating Weight (kg) 79 108
Cabinet Code Cas 4 Cas 4
Cabinet Finish Painted Painted
Refrigeration
Capacity (KW) 2.9 5.8
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Co-Axial or Plate Co-Axial or Plate
Unit Operation Cooling Only Cooling Only
Compressor Style Rotary Rotary
Number Compressors 1 1
Comp Capacity Control None None
Gas Type R407C R407C
Gas Charge (kg) 2.5 2.9
Fan Type Axial Axial
Noise Level (dB(A)) 45 58
Electrical
Power Supply (V/PH/Hz) 230V 50Hz 1Ph 230V 50Hz 1Ph
RLA 11.6 12
FLA 12.6 13.6
LRA 26.4 41
Auto Program Controller Yes Yes
Controller Type Digital
Thermostat Digital
Thermostat
Comp Time Delay Yes Yes
Auto Restart Yes Yes
External Controls None None
Control Stages 1 1
Water
Pump In-built No No
Water Flow (l/s) Required 0.14 0.28
Rated Pump Head (min) 10M / 1bar 10M / 1bar
Water Tank No No
Prevention from freezing No No
Pipe Size mm (supply) 25 25
Pipe Size mm (return) 25 25
Internal Bypass No No
Include Flow Switch Yes Yes
10
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia
Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
Chiller Range: MWC-7-7kW to 16kW
Key Features (Model) UMWC-7-7 UMWC-7-9 UMWC-7-11 UMWC-7-14 UMWC-7-16
kW Size 7.3 9 11 14 16
Water Supply Temp (◦C) 7 7 7 7 7
Water Return Temp (◦C) 12 12 12 12 12
Cabinet
Length (mm) 990 990 990 990 990
Depth (mm) 680 680 680 680 680
Height (mm) 1220 1220 1220 1220 1220
Shipping Weight (kg) 110 115 120 125 130
Operating Weight (kg) 120 125 130 135 140
Cabinet Code Cas 5 Cas 5 Cas 5 Cas 5 Cas 5
Cabinet Finish Painted Painted Painted Painted Painted
Refrigeration
Capacity (KW) 7.3 9 11 14 16
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Co-Axial / Plate Co-Axial / Plate Co-Axial / Plate Co-Axial / Plate Co-Axial / Plate
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style Hermetic Scroll Hermetic Scroll Hermetic Scroll Hermetic Scroll Hermetic Scroll
Number Compressors 1 1 1 1 1
Comp Capacity Control None None None None None
Gas Type R407C R407C R407C R407C R407C
Gas Charge (kg) 2.5 2.7 3.0 3.2 3.5
Fan Type Axial Axial Axial Axial Axial
Noise Level (dB(A)) 55 55 55 55 55
Electrical
Power Supply (V/PH/Hz) 230V 50Hz 1Ph 230V 50Hz 1Ph 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
RLA 12 13 7 8 9
PLA 13.3 15.3 9.1 11.1 11.1
LRA 40 46 28 34 36
Auto Program Controller Yes Yes Yes Yes Yes
Controller Type Digital
Thermostat Digital
Thermostat Digital
Thermostat Digital
Thermostat Digital
Thermostat
Comp Time Delay Yes Yes Yes Yes Yes
Auto Restart Yes Yes Yes Yes Yes
External Controls None None None None None
Control Stages 1 1 1 1 1
Water
Pump In-built No No No No No
Water Flow (l/s) Required 0.35 0.43 0.53 0.67 0.76
Rated Pump Head (min) 10M / 1bar 10M / 1bar 10M / 1bar 10M / 1bar 10M / 1bar
Water Tank No No No No No
Prevention from freezing No No No No No
Pipe Size mm (supply) 25 25 25 25 25
Pipe Size mm (return) 25 25 25 25 25
Internal Bypass No No No No No
Include Flow Switch Yes Yes Yes Yes Yes
11
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Chiller Range: USDA-7-22kW to 45kW (Cas17)
Key Features (Model) USDA-7-22-Cas17 USDA-7-28-Cas17 USDA-7-38-Cas17 USDA-7-45-Cas17
kW Size 22 28 38 45
Water Supply Temp (◦C) 7 7 7 7
Water Return Temp (◦C) 12 12 12 12
Cabinet
Length (mm) 1530 1530 1530 1530
Depth (mm) 760 760 760 760
Height (mm) 1850 1850 1850 1850
Shipping Weight (kg) 860 860 860 860
Operating Weight (kg) 865 865 865 865
Cabinet Code Cas 17 Cas 17 Cas 17 Cas 17
Cabinet Finish Painted Painted Painted Painted
Refrigeration
Capacity (KW) 22 28 38 45
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Plate Plate Plate Plate
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style Hermetic Scroll Semi-Hermetic Scroll Semi-Hermetic Scroll Semi-Hermetic Scroll
Number Compressors 1 1 1 1
Comp Capacity Control None None None None
Gas Type R407C R407C R407C R407C
Gas Charge (kg) 6 6.5 8 8.5
Fan Type Axial Axial Axial Axial
Noise Level (dB(A)) 63 65 66 66
Electrical
Power Supply (V/PH/Hz) 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
RLA 19 22 29 35
FLA 23.7 28.7 34.7 40.7
LRA 126 137 204 232
Auto Program Controller Yes Yes Yes Yes
Controller Type Micro Processor Micro Processor Micro Processor Micro Processor
Comp Time Delay Yes Yes Yes Yes
Auto Restart Yes Yes Yes Yes
External Controls Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop
Control Stages 1 1 1 1
Water
Pump In-built No No No No
Water Flow (l/s) Required 1.1 1.3 1.8 2.2
Pressure Drop (kPa) 20 20 20 20
Water Tank No No No No
Prevention from freezing No No No No
Pipe Size mm (supply) 32 32 40 40
Pipe Size mm (return) 32 32 40 40
Internal Bypass No No No No
Include Flow Switch Terminals Terminals Terminals Terminals
12
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia
Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
Chiller Range: USDA-7-55kW to 85kW (Cas17)
Key Features (Model) USDA-7-55-Cas17 USDA-7-65-Cas17 USDA-7-75-Cas17 USDA-7-85-Cas17
kW Size 55 65 75 85
Water Supply Temp (◦C) 7 7 7 7
Water Return Temp (◦C) 12 12 12 12
Cabinet
Length (mm) 1530 1530 1530 1530
Depth (mm) 760 760 760 760
Height (mm) 1850 1850 1850 1850
Shipping Weight (kg) 860 860 860 860
Operating Weight (kg) 865 865 865 865
Cabinet Code Cas 17 Cas 17 Cas 17 Cas 17
Cabinet Finish Painted Painted Painted Painted
Refrigeration
Capacity (KW) 55 65 75 85
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Plate Plate Plate Plate
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style Semi-Hermetic Scroll Semi-Hermetic Scroll Semi-Hermetic Scroll Semi-Hermetic Scroll
Number Compressors 1 1 2 2
Comp Capacity Control None None None None
Gas Type R407C R407C R407C R407C
Gas Charge (kg) 8.5 10 12 16
Fan Type Axial Axial Axial Axial
Noise Level (dB(A)) 67 67 72 72
Electrical
Power Supply (V/PH/Hz) 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
RLA 40 45 72 80
FLA 44.7 49.7 77.7 85.4
LRA 273 273 396 424
Auto Program Controller Yes Yes Yes Yes
Controller Type Micro Processor Micro Processor Micro Processor Micro Processor
Comp Time Delay Yes Yes Yes Yes
Auto Restart Yes Yes Yes Yes
External Controls Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop
Control Stages 1 1 1 1
Water
Pump In-built No No No No
Water Flow (l/s) Required 2.6 3.1 3.6 4.1
Pressure Drop (kPa) 20 20 20 20
Water Tank No No No No
Prevention from freezing No No No No
Pipe Size mm (supply) 50 50 50 50
Pipe Size mm (return) 50 50 50 50
Internal Bypass No No No No
Include Flow Switch Terminals Terminals Terminals Terminals
13
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Chiller Range: USDA-7-75kW to 140kW
Key Features (Model) USDA-7-95 USDA-7-125 USDA-7-140
kW Size 95 125 140
Water Supply Temp (◦C) 7 7 7
Water Return Temp (◦C) 12 12 12
Cabinet
Length (mm) 1480 1480 1480
Depth (mm) 1310 1310 1310
Height (mm) 2020 2020 2020
Shipping Weight (kg) 490 510 525
Operating Weight (kg) 510 530 545
Cabinet Code Cas 1 Cas 1 Cas 1
Cabinet Finish Painted Painted Painted
Refrigeration
Capacity (KW) 95 125 140
Condenser Design Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Vertical Shell and
Tube Vertical Shell and
Tube Vertical Shell and
Tube
Unit Operation Cooling Only Cooling Only Cooling Only
Compressor Style Recip or Screw Screw Screw
Number Compressors 1 1 1
Comp Capacity Control Step 100 / 50 Step 100 / 75 / 50 Step 100 / 75 / 50
Gas Type R407C R407C R407C
Gas Charge (kg) 14 20 23
Fan Type Axial Axial Axial
Noise Level (dB(A)) 78 78 78
Electrical
Power Supply (V/PH/Hz) 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
Full load Amps (Comp + Fan) 91.8 115.8 117.8
Full load Amps (Pump) - - -
Total Full Amps 91.8 115.8 117.8
Start Amps (excl Pump) 275.4 347.4 353.4
Auto Program Controller Yes Yes Yes
Controller Type Micro Processor Micro Processor Micro Processor
Comp Time Delay Yes Yes Yes
Auto Restart Yes Yes Yes
External Controls Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop
Control Stages 2 3 3
Water
Pump In-built No No No
Water Flow (l/s) 4.5 6 6.7
Rated Pump Head Not included Not included Not included
Tank and Water make up No No No
Water Tank No No No
Prevention from freezing No No No
Pipe Size mm (supply) 75 75 75
Pipe Size mm (return) 75 75 75
Internal Bypass No No No
Include Flow Switch Terminals Terminals Terminals
14
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia
Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
Chiller Product: Cold Spa Chiller
** Includes all water piping suitable for swimming pool / spa water
Key Features (Model) UMWC-7-7.0-Spa
kW Size 7.3
Water Supply Temp (◦C) 7
Water Return Temp (◦C) 9
Cabinet
Length (mm) 990
Depth (mm) 830
Height (mm) 1220
Shipping Weight (kg) 115
Operating Weight (kg) 125
Cabinet Code Cas 5
Cabinet Finish Painted
Refrigeration
Capacity (KW) 7.3
Condenser Design Air Cooled Aluminium
Evaporator Design Stainless Plate
Unit Operation Cooling Only
Compressor Style Hermetic Scroll
Number Compressors 1
Comp Capacity Control None
Gas Type R407C
Gas Charge (kg) 3
Fan Type Axial
Noise Level (dB(A)) 61
Electrical
Power Supply (V/PH/Hz) 230V 50Hz 1Ph
Full load Amps (Comp + Fan) 11
Full load Amps (Pump) 14.5
Total Full Amps 16
Start Amps (excl Pump) 45
Auto Program Controller Yes
Controller Type Digital Thermostat
Comp Time Delay Yes
Auto Restart Yes
External Controls None
Control Stages 1
Water
Pump In-built Yes
Water Flow (l/s) 1.0
Rated Pump Head (min) 10M / 1bar
Tank and Water make up No
Water Tank No
Prevention from freezing Yes
Pipe Size mm (supply) 25
Pipe Size mm (return) 25
Internal Bypass No
Include Flow Switch Yes
15
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Chiller Range: USMC-6-120kW to 240kW – Scroll Option
Key Features (Model) USMC-6-120 USMC-6-150 USMC-6-190 USMC-6-240
kW Size 120 150 190 240
Water Supply Temp (◦C) 7 7 7 7
Water Return Temp (◦C) 12 12 12 12
Cabinet
Length (mm) 3000 3000 3000 3000
Depth (mm) 2025 2025 2025 2025
Height (mm) 2225 2230 2230 2230
Shipping Weight (kg)
Operating Weight (kg)
Cabinet Code Cas 34 Cas 34 Cas 34 Cas 34
Cabinet Finish Painted Painted Painted Painted
Refrigeration
Capacity (KW) 120 150 190 240
Condenser Design Air Cooled Aluminium Air Cooled Aluminium Air Cooled Aluminium Air Cooled Aluminium
Evaporator Design Shell and Tube Shell and Tube Shell and Tube Shell and Tube
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style Semi-Hermetic Scroll Semi-Hermetic Scroll Semi-Hermetic Scroll Semi-Hermetic Scroll
Number Compressors 4 4 4 4
Comp Capacity Control Step 100 / 75 / 50 / 25 Step 100 / 75 / 50 / 25 Step 100 / 75 / 50 / 25 Step 100 / 75 / 50 / 25
Gas Type R407C R407C R407C R407C
Gas Charge (kg) 26 32 34 48
Fan Type Axial Axial Axial Axial
Noise Level (dB(A)) 75.2 76.5 76.6 76.6
Electrical
Power Supply (V/PH/Hz) 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
RLA 83 107 128 158
FLA 104 133 160 197
LRA 570 788 910 1084
Auto Program Controller Yes Yes Yes Yes
Controller Type Micro Processor Micro Processor Micro Processor Micro Processor
Comp Time Delay Yes Yes Yes Yes
Auto Restart Yes Yes Yes Yes
External Controls Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop
Control Stages 4 4 4 4
Water
Pump In-built No No No No
Water Flow (l/s) Required 5.7 7.2 9.1 11.5
Rated Pump Head Not included Not included Not included Not included
Water Tank No No No No No No
Prevention from freezing No No No No
Pipe Size mm (supply) 100 100 100 100
Pipe Size mm (return) 100 100 100 100
Internal Bypass No No No No
Include Flow Switch No No No No
16
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia
Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
Chiller Range: USMC-6-220kW to 300kW – Screw Option
Key Features (Model) USMC-6-220 USMC-6-250 USMC-6-300
kW Size 220 250 300
Water Supply Temp (◦C) 7 7 7
Water Return Temp (◦C) 12 12 12
Cabinet
Length (mm) 3250 3250 3250
Depth (mm) 2400 2400 2400
Height (mm) 2225 2225 2225
Shipping Weight (kg)
Operating Weight (kg)
Cabinet Code Cas 31 Cas 31 Cas 31
Cabinet Finish Painted Painted Painted
Refrigeration
Capacity (KW) 220 250 300
Condenser Design Air Cooled Aluminium Air Cooled Aluminium Air Cooled Aluminium
Evaporator Design Shell and Tube Shell and Tube Shell and Tube
Unit Operation Cooling Only Cooling Only Cooling Only
Compressor Style Screw Screw Screw
Number Compressors 2 2 2
Comp Capacity Control Step 100 / 75 / 50 / 25 Step 100 / 75 / 50 / 25 Step 100 / 75 / 50 / 25
Gas Type R407C R407C R407C
Gas Charge (kg) 40 46 50
Fan Type Axial Axial Axial
Noise Level (dB(A)) 75.2 76.5 76.6
Electrical
Power Supply (V/PH/Hz) 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
RLA 135 153 166
FLA 185.4 205.4 273.4
LRA 626 766 580
Auto Program Controller Yes Yes Yes
Controller Type Micro Processor Micro Processor Micro Processor
Comp Time Delay Yes Yes Yes
Auto Restart Yes Yes Yes
External Controls Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop
Control Stages 4 4 4
Water
Pump In-built No No No
Water Flow (l/s) 7.56 9.16 11.15
Rated Pump Head Not included Not included Not included
Water Tank No No No
Prevention from freezing No No No
Pipe Size mm (supply) 100 100 100
Pipe Size mm (return) 100 100 100
Internal Bypass No No No
Include Flow Switch No No No
17
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Chiller Range: USMC-6-360kW to 450kW – Screw Option
Key Features (Model) USMC-6-360 USMC-6-400 USMC-6-450
kW Size 360 400 450
Water Supply Temp (◦C) 7 7 7
Water Return Temp (◦C) 12 12 12
Cabinet
Length (mm) 4800 4800 4800
Depth (mm) 3250 3250 3250
Height (mm) 2225 2225 2225
Shipping Weight (kg)
Operating Weight (kg)
Cabinet Code Cas 31 Cas 31 Cas 31
Cabinet Finish Painted Painted Painted
Refrigeration
Capacity (KW) 360 400 450
Condenser Design Air Cooled Aluminium Air Cooled Aluminium Air Cooled Aluminium
Evaporator Design Shell and Tube Shell and Tube Shell and Tube
Unit Operation Cooling Only Cooling Only Cooling Only
Compressor Style Screw Screw Screw
Number Compressors 1 1 2
Comp Capacity Control Step 100 / 75 / 50 / 25 Step 100 / 75 / 50 / 25 Step 100 / 75 / 50 / 25
Gas Type R407C R407C R407C
Gas Charge (kg) 50 55 60
Fan Type Axial Axial Axial
Noise Level (dB(A)) 75.2 76.5 76.6
Electrical
Power Supply (V/PH/Hz) 400V 50Hz 3Ph 400V 50Hz 3Ph 400V 50Hz 3Ph
RLA 202 219 270
FLA 295.4 325.4 409.4
LRA 493 583 676
Auto Program Controller Yes Yes Yes
Controller Type Micro Processor Micro Processor Micro Processor
Comp Time Delay Yes Yes Yes
Auto Restart Yes Yes Yes
External Controls Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop Gen Fault / Remote
Start & Stop
Control Stages 4 4 4
Water
Pump In-built No No No
Water Flow (l/s) Required 17.2 19.1 21.5
Rated Pump Head Not included Not included Not included
Water Tank No No No
Prevention from freezing No No No
Pipe Size mm (supply) 100 100 100
Pipe Size mm (return) 100 100 100
Internal Bypass No No No
Include Flow Switch No No No
18
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia
Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
Chiller Range: USMC-6-500kW to 900kW – Screw Option
Key Features (Model) USMC-6-500 USMC-6-600 USMC-6-720 USMC-6-800 USMC-6-900
kW Size 500 600 720 800 900
Water Supply Temp (◦C) 7 7 7 7 7
Water Return Temp (◦C) 12 12 12 12 12
Cabinet
Length (mm) 4800 4800 4800 4800 4800
Depth (mm) 3250 3250 3250 3250 3250
Height (mm) 2225 2225 2225 2225 2225
Shipping Weight (kg)
Operating Weight (kg)
Cabinet Code 2 x Cas 31 2 x Cas 31 2 x Cas 31 2 x Cas 31 2 x Cas 31
Cabinet Finish Painted Painted Painted Painted Painted
Refrigeration
Capacity (KW) 500 600 720 800 900
Condenser Design Air Cooled
Aluminium Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Shell & Tube Shell & Tube Shell & Tube Shell & Tube Shell & Tube
Unit Operation Cooling Only Cooling Only Cooling Only Cooling Only Cooling Only
Compressor Style SemiHermetic
Screw SemiHermetic
Screw SemiHermetic
Screw SemiHermetic
Screw SemiHermetic
Screw
Number Compressors 4 4 2 2 4
Comp Capacity Control Step 100 / 75
/ 50 / 25 Step 100 / 75
/ 50 / 25 Step 100 / 75
/ 50 / 25 Step 100 / 75
/ 50 / 25 Step 100 / 75
/ 50 / 25
Gas Type R407C R407C R407C R407C R407C
Gas Charge (kg) 92 100 100 110 120
Fan Type Axial Axial Axial Axial Axial
Noise Level (dB(A)) 76.5 76.6 75.2 76.5 76.6
Electrical
Power Supply (V/PH/Hz) 400V 50Hz
3Ph 400V 50Hz
3Ph 400V 50Hz
3Ph 400V 50Hz
3Ph 400V 50Hz
3Ph
RLA 306 332 404 438 540
FLA 411 548 591 651 820
LRA 1532 1160 946 1166 1352
Auto Program Controller Yes Yes Yes Yes Yes
Controller Type Mcr Prcssr Mcr Prcssr Mcr Prcssr Mcr Prcssr Mcr Prcssr
Comp Time Delay Yes Yes Yes Yes Yes
Auto Restart Yes Yes Yes Yes Yes
External Controls
Gen Fault / Remote Start
& Stop
Gen Fault / Remote Start
& Stop
Gen Fault / Remote Start
& Stop
Gen Fault / Remote Start
& Stop
Gen Fault / Remote Start
& Stop
Control Stages 4 4 4 4 4
Water
Pump In-built No No No No No
Water Flow (l/s) Required 23.9 28.7 34.4 38.2 43
Rated Pump Head Not included Not included Not included Not included Not included
Water Tank No No No No No
Prevention from freezing No No No No No
Pipe Size mm (supply) 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100
Pipe Size mm (return) 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100
Internal Bypass No No No No No
19
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: [email protected] Web: www.matsu.com.au
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
CHILLER CATALOGUE
Notes: