Sun SPARC Enterprise®M8000 ServerMainframe reliability with industry-leading virtualization and extreme scalability
Highlights
• Optimized for 24x7 mission critical computing and large shared memory applications
• Unmatched investment protection with no forklift upgrades - upgrade individual components, not the whole system
• 100% binary compatibility with earlier versions of your applications
• Mainframe class reliability, availability, serviceability (RAS)
• Mix and match up to sixteen quad-core SPARC64 VII processors and/or dual-core SPARC64 VI processors in the same system
• Built-in, no-cost, and flexible virtualization technology
• Ideal consolidation platform with up to 16 dynamic domains and thousands of Solaris Containers per system
Investment protection and mainframe-
class RAS in a highly flexible system
Sun’s SPARC Enterprise M8000 server provides
the highest reliability and unmatched
investment protection. With no forklift
upgrades, the Sun SPARC Enterprise M8000
server protects your IT investment. The option
to mix and match different speeds/generations
of SPARC64 processors in existing and new M-
series servers provides the level of investment
protection and reliability not offered by IBM or
HP. In addition, RAS features come standard
in the Sun SPARC Enterprise M8000 server—
features like automatic recovery with instruction
retry, up to 1 TB of system memory error-
correcting code (ECC) protection with extended
ECC support, guaranteed data-path integrity,
total SRAM and register protection, and
configurable memory mirroring. Major system
components are redundant and hot-swappable,
providing the superior reliability and availability
required by a 24x7 compute infrastructure.
Solaris: the world’s most advanced OS
Only Sun legally assures investment protection
with Solaris OS with 100% binary compatiblity
for the past 15 years and counting. The SPARC
Enterprise M8000 server somes preinstalled
with Solaris 10 OS. The Solaris 10 OS also deliv-
ers revolutionary features, including Dynamic
Tracing (DTrace), Solaris ZFS, crypto- graphic
infrastructures, IP filter, and User and Process
Rights Management.
Advanced consolidation and virtualization
Industry-leading virtualization features make
the Sun SPARC Enterprise M8000 server one of
Sun’s most advanced consolidation systems. It
supports up to 16 Dynamic Domains, enabling
massive server consolidation and datacenter
virtualization. Each physical domain can also
be further optimized through the use of Solaris
Containers, enabling each Sun SPARC Enterprise
M8000 server to support thousands ofsoftware
partitions.
For 24/7 mission-critical services, this system delivers extensive expansion and virtualization
capabilities as well as mainframe-class RAS. Customize it with mix-and-match configurability
using the latest high-performance SPARC64 VII quad-core and SPARC64 VI dual-core proces-
sors and the Solaris 10™ Operating System, the Sun SPARC Enterprise® M8000 server is optimized for
enterprise-class applications such as ERP, CRM, BIDW, large databases, HPC/scientific/engineering, and
large-scale OLTP applications.
>
2
Learn MoreThe Sun SPARC Enterprise M8000 server belongs to a family of midrange servers designed to satisfy a large range of workloads and applications. For more information, visit sun.com/m8000 or talk to a local Sun sales representative.
Processor
CPU Choiceofupto16SPARC64VIIquad- coreor16SPARCVIdual-coreproces sorsSPARCV9Architecture,ECC protected
CacheperSPARC64 •SPARC64VII:64KBD-cacheandLevel1 64KBI-Cache •SPARC64VI:128KBD-cacheand 128KBI-Cache
CacheperSPARC64 •SPARC64VII:6MBon-chipLevel2 •SPARC64VI:5MBto6MBon-chip
Clockspeed •SPARC64VII:2.88GHz •SPARC64VI:2.28GHzto2.4GHz
System
CPU •UptofourCPUmemory boards(CMU),withuptofour processorsperboard;upto256GB ofmemoryperboardbasedon8 GBDIMMs
Mainmemory •Upto1TBpersystem
I/O •UptofourI/Ounits(IOU)with eightPCIeslotseach/32PCIeslots persystem •Upto112PCIeandPCI-Xslots withtheoptionalExternalI/O ExpansionUnit
Systembus •High-speed,low-latencyintercon nectsystembuswithredundant data,address,andresponse crossbarinterconnect
Systembusbandwidth •184GB/secpeak,60.3GB/sec(memory) stream(copy)
Systembusbandwidth •61GB/secpeak(I/O)
Tworedundantserviceprocessors
Upto16DynamicDomains
Storage
Bootdevice •Upto16internal,2.5in.SAS bootdisks
Externalboot •SunStorageTek2540,3120,devicessupported 3510FC,9980,9985, J4200,J4400,J4500
External •Direct,SANorNASattachedto SunStorageTekcompatibletape librariesanddiskarrays,including StorageTek3X00,5X00,6X00,and 9X00families
Resource management
DynamicDomains
Solaris10ResourceManagerincludingSolarisContainers
Software
Operatingsystem •SPARC64VII(2.88GHz): Solaris10(10/08)orSolaris10 (8/07)withSolaris1010/09 PatchBundleandtheSunAlert PatchCluster •SPARC64VI(2.28GHz,2.4GHz): Solaris10(11/06)orlater
Languages •C,C++,Pascal,FORTRAN,Java™
Networking •ONC™/NFS™,TCP/IP,SunLink™, Netware
Systemmonitoring •SunManagementCenter •SolarisWebStart •SolsticeDomainManager •SolsticeEnterpriseManager™ •SolsticeBackup™ •xVMOpsCenter
Valueaddedsoftware •VERITASFileSystem •VERITASVolumeManager •SunCluster™ •SunHPCClusterTools™ •SunJavaEnterpriseSystem
Environmental
PowerOption1 •ACpower:200–240VAC1-phase (50/60Hz),30A •Powercords:Three(Sixwiththe optionaldualpowerfeed) •Plug:NEMA-L6-30P(U.S.)or EN60309(32A)(INTL)
PowerOption2 •ACpower:208VAC3-phaseDELTA (50/60Hz),50A •Powercords:Twodirectwired powerconnections;includesdual powerfeed
PowerOption3 •ACpower415VAC3-phase STAR(50/60Hz),30A •Powercords:Twodirectwired powerconnections;includesdual powerfeed
Operatingtemperature •5°Cto32°C(41°Fto89.6°F),20%to 80%relativehumidity, noncondensing
Nonoperatingtemperature •0°Cto50°C(32°Fto122°F) 8%to80%relativehumidity, noncondensing
Altitude •Upto3000m(9,843ft.)
Regulations (meets or exceeds the following requirements)
Safety •CSA/UL-60950,EN60950,IEC950CB Schemewithallnationaldeviations
RFI/EMC •EN55022/CISPR22ClassA, FCCCFR47Part15ClassA, EN61000-3-2,EN61000-3-3
Immunity •EN55024,EN61000-4-2,-4-3,-4-5, -4-6,-4-8,and-4/11
•CE,FCC,ICES,C-tick,VCCI,GOST-R, BSMI,MIC,CSA/UL
Othermarks •WEEEandChineseRoHS
KeyRAS features
End-to-endECCprotection;guaranteeddata-pathintegrity;automaticrecoverywithinstructionretry;totalSRAMandregisterprotection;DynamicL1andL2cachelinedegradation;ECCandExtendedECCprotectionformemory,memorymirroring,andPredictiveSelf-Heal-ing;fault-isolatedDynamicDomains;DynamicReconfiguration;AutoDiagnosisandRecovery;onlineupgrades;concurrentmaintenanceofdisks,fans,andpowersupplies;redundantnetworkconnections;liveoperatingsystemupgrades;journalingfilesystem;hardenedI/Odrivers;individualcoreorCPUoff-lining;memorypageretirement;andclustersupport.
Sun Upgrade Advantage Program
TheSunUpgradeAdvantageProgram(UAP)offersinvestmentprotectionprogramstomigratecustomersfromSunandcompetitorplatforms,withdiscountsfortrade-inofqualifiedSunandcompeti-tiveserverstowardnewSunSPARCEnterpriseservers.Trade-inallow-ancesarealsoavailablewhenacustomerupgradesfromapreviousgenerationSPARC64VIandVIICPUstoSun’slatestCPUgeneration.Formoreinformationvisitsun.com/ibb/enterprise.
Dimensions and weight
H: 180cm(70.9in.)
W: 75cm(29.5in.)
D: 126cm(49.6in.)
Weight: 700kg(1540lb.)
Optional power expansion cabinet required for 3-phase power distribution
H: 180cm(70.9in.)
W: 31.7cm(12.5in.)
D: 124.4cm(49in.)
Weight: 350kg(770lb.)
Remote services
SunConnect
Services
Sunprovidesanend-to-endportfolioofservicesdesignedtoacceler-atethealignmentofITinfrastructurewithbusinessneeds,optimizeusageofITassets,andcontaincosts.Sun’sexpertisehelpsyouad-dresskeydatacenterchallenges,includingconsolidation,availability,clustering,optimization,anddisasterrecovery.LeverageSun’smorethan25yearsofrelentlessinnovationanddepthofexpertisetohelpyouarchitectanddeployareliable,high-performanceSunSPARCEnterpriseM8000solutionthatgivesyouacompetitiveedge.
© 2008 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, the Sun logo, Enterprise, Java, Solaris, StorageTek, ONC, Solstice Enterprise Manager, Sun HPC ClusterTools, SunLink, Solstice Backup, SunVIP, and SunSpectrum are trademarks or registered trademarks of Sun Microsystems, Inc. or its subsidiaries in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trade-marks of SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. Information subject to change without notice. SunWIN #490800 Lit. #SYDS12584-1 10/09
Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA Phone 1-650-960-1300 or 1-800-555-9SUN Web sun.com
Sun SPARC Enterprise M8000 Server
Data Sheet Sun SPARC® Enterprise M8000 Server sun.com/m8000