Turnkey Delivery • Complete with medium-voltage transformer and concrete substation for outdoor installation SUNNY CENTRAL for direct medium-voltage feed-in 400MV / 500MV / 630MV The compact station for safe grid management The station has got it: Equipped with an SMA central inverter of the new HE family and a medium-voltage transformer, the Sunny Central MV feeds directly into the medium-voltage grid. The advantage: By removing the need for the low-voltage trans- former, the plant operator realizes greater yields and at the same time lower inverter costs. The Sunny Central MV is delivered as a “turnkey” concrete substation for outside installation. On top of that, the Sunny Central MV actively participates in grid management, and thereby fulfils all requirements of the Medium-Voltage Directive valid as of July 2010. Optional • Medium-voltage switchgear systems for a flexible structure of large solar parks • AC transfer station with measurement • Medium-voltage transformers for other grid voltages (deviating from 20 kV) Efficient • Without low-voltage transformer: greater plant efficiency due to direct connection to the medium- voltage grid SUNNY CENTRAL 400MV / 500MV / 630MV SC 400MV-11 / SC 500MV-11 / SC 630MV-11

Upload: others

Post on 10-Dec-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Turnkey Delivery•Completewithmedium-voltage

transformerandconcretesubstationforoutdoorinstallation

Sunny CenTral for direct medium-voltage feed-in 400MV / 500MV / 630MV The compact station for safe grid management

Thestationhasgotit:EquippedwithanSMAcentralinverterofthenewHEfamilyandamedium-voltagetransformer,theSunnyCentralMVfeedsdirectlyintothemedium-voltagegrid.Theadvantage:Byremovingtheneedforthelow-voltagetrans-former,theplantoperatorrealizesgreateryieldsandatthesametimelowerinvertercosts.TheSunnyCentralMVisdeliveredasa“turnkey”concretesubstationforoutsideinstallation.Ontopofthat,theSunnyCentralMVactivelyparticipatesingridmanagement,andtherebyfulfilsallrequirementsoftheMedium-VoltageDirectivevalidasofJuly2010.

Optional•Medium-voltageswitchgear

systemsforaflexiblestructureoflargesolarparks

•ACtransferstationwithmeasurement

•Medium-voltagetransformers

forothergridvoltages(deviatingfrom20kV)

efficient•Withoutlow-voltagetransformer:

greaterplantefficiencyduetodirectconnectiontothemedium-voltagegrid

Sunny CenTral 400MV / 500MV / 630MVSC

400

MV-

11 /

SC 5

00M

V-11

/ S

C 63

0MV-

11

Technical dataSunny Central

400MVSunny Central

500MVSunny Central

630MVInput dataNominalDCpower 408kW 509kW 642kWMax.DCpower 450kWp1) 560kWp1) 705kWp1)MPPvoltagerange 450V–820V5) 450V–820V5) 500V–820V5)7)Max.DCvoltage 1000V 1000V 1000VMax.DCcurrent 993A 1242A 1422ANumberofDCinputs (8+8)+2DCHV (8+8)+2DCHV (8+8)+2DCHVOutput dataNominalACpower@45°C 400kVA 500kVA 630kVAContinuousACpower@25°C 440kVA 550kVA 700kVANominalACvoltage 20000V 20000V 20000VNominalACcurrent 11.55A 14.4A 18.18AACgridfrequency50Hz ● ● ●ACgridfrequency60Hz ● ● ●Powerfactor(cosϕ) 0.9leading...0.9laggingMax.THD <3% <3% <3%Power consumptionInternalconsumptioninoperation <1500W4) <1500W4) <1500W4)Standbyconsumption <100W+720W <100W+720W <100W+860WExternalauxiliarysupplyvoltage 3x230V,50/60Hz 3x230V,50/60Hz 3x230V,50/60HzExternalback-upfuseforauxiliarysupply B20A,3-pole B20A,3-pole B20A,3-poleDimensions and weightHeight 3600mm 3600mm 3600mmWidth 5300mm 5300mm 5300mmDepth 2500mm 2500mm 2500mmWeight 30000kg 30000kg 30000kgEfficiency 2)

Max.efficiency 97.5% 97.7% 97.8%Euro-eta 97.1% 97.3% 97.4%Protection rating and ambient conditions Protectionrating(asperEN60529) IP54 IP54 IP54Operatingtemperaturerange –20°C…+45°C –20°C…+45°C –20°C…+45°CRel.humidity 15%…95% 15%…95% 15%…95%Freshairconsumption 6200m3/h 6200m3/h 6200m3/hMax.altitude(abovesealevel) 1000m 1000m 1000m

SUNNY CENTRAL 400MV / 500MV / 630MV

Sunny Central400MV

Sunny Central500MV

Sunny Central630MV

Sunny Central400MV

Sunny Central500MV

Sunny Central630MV

HE:HighEfficiency,inverterwithoutgalvanicisolationforconnectiontoamedium-voltagetransformer(takingintoaccounttheSMAspecificationforthetransformer)1)SpecificationsapplytoirradiationvaluesbelowSTC2)EfficiencymeasuredwithoutaninternalpowersupplyatUDC=500V3)2xinputsfortheexternalnominalvaluespecificationforactivepowerandreactivepower,1xexternalalarminput,1xirradiationsensor,1xpyranometer4)Internalconsumptionatnominalpower5)At1.05UAC,nomandcosϕ=16)Withlimiteddynamicgridsupport7)Atfgrid=60Hz:510V-820VPlease note: incertaincountriesthesubstationsmaydifferfromthesubstationsshownintheimages

FeaturesDisplay:textline/graphic ●/— ●/— ●/—Groundfaultmonitoring ● ● ●Heating ● ● ●Emergencystop ● ● ●CircuitbreakerACside SIloaddisconnectionswitch SIloaddisconnectionswitch SIloaddisconnectionswitchCircuitbreakerDCside Switch-disconnector

withmotorSwitch-disconnector

withmotorSwitch-disconnector

withmotorMonitoredovervoltageprotectorsAC/DC ●/● ●/● ●/●Monitoredovervoltageprotectorsforauxiliarysupply ● ● ●SCC (Sunny Central Control) interfacesCommunication(NETPiggy-Back,optional) analog,ISDN,Ethernet analog,ISDN,Ethernet analog,ISDN,EthernetAnaloginputs 5xAin3) 5xAin3) 5xAin3)Overvoltageprotectionforanaloginputs ○ ○ ○SunnyString-Monitorconnection(COM1) RS485 RS485 RS485PCconnection(COM3) RS232 RS232 RS232Electricallyseparatedrelay(ext.alertsignal) 1 1 1Certificates / listingsEMC EN61000-6-2EN61000-6-4CEconformity ● ● ●BDEW-MSRL/FGW/TR86) ● ● ●RD1633/2000 ● ● ●Arrêtédu23/04/08 ● ● ●●standardfeatures○optionalfeatures—notavailableTypedesignation SC400MV-11 SC500MV-11 SC630MV-11

SMa Solar Technology aGwww.SMa-Solar.com

limited Dynamic Grid SupportTheinvertercontinuestofeedtothegridaftershorttermvoltagedrops–aslongasthegridvoltageiswithinadefinedvoltagewindow.

remote controlled power reduction in case of grid overloadInordertoavoidshort-termgridoverload,thegridoperatorpresetsanominalactivepowervaluewhichtheinverterwillimplementwithin60seconds.ThenominalvalueistransmittedtotheinvertersviaaripplecontrolreceiverincombinationwiththeSMAPowerReducerBox.Typicallimitvaluesare100,60,30or0percentofthenominalpower.

Frequency-dependent control of active powerAsofagridfrequencyof50.2Hz,theinverterautomaticallyreducesthefed-inofactivepoweraccordingtoadefinablecharacteristiccurvewhichtherebycontributestothestabilizationofthegridfrequency.

Static voltage support based on reactive powerTostabilizethegridvoltage,SMAinvertersfeedreactivepower(leadingorlagging)intothegrid.Threedifferentmodesareavailable:

a) Fixed definition of the reactive power by the grid operatorThegridoperatordefinesafixedreactivepowervalueorafixeddisplacementfactorbetweencos(ϕ)leading=0.90andcos(ϕ)lagging=0.90.

b) Definition of a dynamic setpoint of the reactive power by the utility operatorThegridoperatordefinesadynamicdisplacementfactor-anyvaluebetweencos(ϕ)leading=0.90undcos(ϕ)lagging=0.90.Itistransmittedeitherthroughacommunicationunit theevaluationcane.g.beevaluatedandprocessedbytheSMAPowerReducerBox.

c) Control of the reactive power over a characteristic curveThereactivepoweror thephaseshift iscontrolledbyapre-definedcharacteristiccurve–dependingontheactivepowerfedintothegridorthegridvoltage.

POwerFul GrID ManaGeMenT FunCTIOnS

SC63

0MV-D

EN10

2320

SM

Aan

dSu

nnyC

entra

larere

gister

edtrad

emarksofS

MA

Solar

Tech

nolog

yAG.T

exta

ndill

ustra

tionsre

flect

thecu

rrent

state

ofth

etec

hnolo

gyatth

etim

eofpub

lication

.Tec

hnica

lmod

ification

sreserve

d.N

olia

bilityfo

rprin

tingerrors.Pr

inted

onch

lorine

-freepa

per.