CEILING SYSTEMS
DC FlexZone™ Suspension Systems
DC FlexZone Suspension System products are heavy-duty main beams equipped with passive electrical conductors. The DC Mains are designed for use with standard cross tees, moldings, and accessories and are installed by acoustical contractors as part of the acoustical ceiling suspension system.
Electrical connections are made to the grid after acoustical installation and are done by qualified electricians. See CS-4327 for electrical contractor tips on connecting EMerge Alliance Registered® components (by others) to DC FlexZone Mains.
Silhouette grid Suprafine grid
acou
stic
al c
ontr
acto
r tip
she
et
NOTICE: DC SUPRAFINE® ROUT HOLE SPACING
6" FROM EACH END, 12" OC.
Remarque: Trous de rainure DC Suprafine espacés à 6 po à chaque bout,
12 po c. à c.
Nota: Perforaciones de conexion
DC Suprafine® a 6" de cada extrema, 12" centro
MD
12
3
4
Do Not Cut the DC FlexZone Main Beams
Use Non-Powered Border Mains at Perimeters – Item Numbers 750106 and 760106 can be field cut;
use both ends of 6' Border Main to minimize scrap
Pay attention to and follow the RCP for location and specific length of mains to install – DC Mains come in 4 different lengths: 6', 8', 10', 12'
– Several different lengths of main beams will likely beused on a job
– Place cartons at job site in areas according to lengths;cartons are white and marked for length
Do Not Mix Standard Mains with DC FlexZone Suprafine Mains – DC Suprafine Mains have different rout hole spacing –
6" from each end and 12" OC
– Suprafine Border Mains (750106) have this same spacing
6" 6"18" 6"18"
8' 8' 8'
18"
SuprafineBorder Main
Suprafine Border Main 750106shall be cut to fit exact roomdimensions. Length can varyup to 6' long.
8' DC FlexZone SuprafineMain Beam DC750108 (shall not be cut), typical
BACG90A Clip
DC Main Beam Border Main Beam
56
7
8
9
Do Not Use Power Key Slots for Hanger Wire
Do Not Re-Use Existing Hanger Wire
Do Not Screw through the Bulb of either Profile – Use BACG90A clips for attachments to the web of
the DC main for seismic applications and bracing
Do Not Use Metal Screws in the DC Silhouette® 1/4" Reveal – Use Partition Clips (UPC) screwed to the
web of the grid for any attachments tothe underside of the grid
Use 2" Insulator Caps if needed to cover conductors with some grid accessories (item # DCINS).
All trademarks used herein are the property of AWI Licensing Company and/or its affiliates© 2011 AWI Licensing Company • Printed in the United States of America
BACG90A Clip
Silhouette grid Suprafine gridSilhouette grid Suprafine grid
ElectricalConductor
DC FlexZoneSilhouette Main Beam
ElectricalConductor
DC FlexZoneSilhouette Main Beam
2" Insulator Cap(DCINS)
For tips for electrical contractors, see CS-4327
For more acoustical installation details, see installation instructions LA-297575
TechLineSM / 1 877 ARMSTRONG 1 877 276 7876 armstrongceilings.com/dcflexzoneCS-4326-311