Swimming Pool Ahu

Download Swimming Pool Ahu

Post on 28-Oct-2014

68 views

Category:

Documents

5 download

Embed Size (px)

TRANSCRIPT

<p>55%</p> <p>[30C]</p> <p>GEA Air Handling Units for swimming pools of every type and size</p> <p>GEA CAIRfricostar Swimming pool climate control with integrated heat recovery</p> <p>[28C]8,000 m3/hGEA Heat Exchangers / HVAC Systems</p> <p>Customised and energy-efficient</p> <p>Sustainable swimming pool climate control with integrated heat recoveryIf you want to not only dehumidify your swimming pool or public baths, but also desire general climate control, then you can succeed especially comfortably and energy-efficiently with the central air handling units of the GEA CAIRfricostar range of models. Well designed, comfortable, and flexible With GEA CAIRfricostar, you have the broadest and most extensive spectrum of dehumidifier units for indoor swimming pools available on the European market. GEA air handling units ensure very high efficiency and selective air exchange. The air on one side of the hall can be evacuated and resupplied on the opposite side. The admixing of fresh air according to VDI 2089 improves the air quality. GEA CAIRfricostar equipment is outstandDehumidification and climate control of public and large pools with the central air handling units of the GEA CAIRfricostar range of models: Highly efficient heat recovery with up to 60% energy savings and high efficiencies of up to 82% Secure, reliable dehumidification Certified according to DIN ISO 9001 Furnished with CE and Eurovent seal Top hygiene standard (also suitable for clinic and rehabilitation applications) according to VDI 6022 Individual, customised units for every application case through modular construction Reliable function for all climatic conditions and constant performance over the entire temperature range Planning support from GEA Air Treatment Multi-stage integrated heat recovery The integrated heat recovery of GEA CAIRfricostar units ensures high amortisation. The humidity is at first removed from the air via heat pump and heat recovery. The resulting condensate is captured and drained off into the waste water system. The interstage heat exchanger for the dehumidification returns the thermal energy recovered in the exhaust air as well as the drive power of the compressor to the pool water and/or the dehumidified air. Well-designed and freely programmable control units ensure the greatest flexibility, energy-optimised functionality, and maintenance of all desired air parameters ing due to its modular design, and especially flexible because also suitable for retrofitting due to small entry openings. With modular technology, an individual unit can be created for every application case. The specialists of GEA Air Treatment will be happy to support you in the tendering, configuration, and selection of the units you need for your individual requirement.</p> <p>2</p> <p>PR-2009-0061-GB Subject to modification Version 02/2009</p> <p>Suited for every use</p> <p>You can optimally plan every swimming pool with GEA CAIRfricostarComfortable private swimming pools, hotel pools, wellness and therapy facilities, or public halls and adventure pools: GEA CAIRfricostar air handling units are optimally suited for every application and work in recirculated air or mixed air operating mode. Regulated share fraction of fresh air in connection with various heat recovery systems with a heat recovery quantity of up to 82% keeps your operating costs within bounds. Features with or without heat pump Depending on the application, the units of the GEA CAIRfricostar range of models offer heat recovery with additional heatpump circuitry as well as heat recovery without additional heatpump circuitry. Units with heat recovery and heat-pump circuitry represent the synthesis of efficacy and air quality. Swimming pool exhaust air drying and fresh air pre-warming, paired with optimised compressor output, lead to low heating costs and save valuable energy. Units with heat recovery but without heat-pump circuit are fundamentally employed for small water surfaces in proportion to a large hall volume. Low maintenance costs and a small investment volume are further arguments for this equipment version. Corrosion protection for long equipment life The cold-bridge-free design of the GEA CAIRfricostar units prevents water formation by condensation and ensures long equipment life. Furthermore, all units can be delivered in three corrosion protection classes: Corrosion protection class K: standard version for use in normal swimming pools Corrosion protection class H: enhanced version for increased requirements in chlorine or saline air (sea water and brine baths up to 3% brine) Corrosion protection class P: top version for very high requirements in aggressive environments such as thermal spas and for salt contents of more than 3%In addition to our modular units, GEA Fricostar Micro offers a compact and ready-to-install swimming pool hall climate-control unit with smaller dimensions</p> <p>Broad performance and geometry spectrum For air volumes of 750 to 45,000 m3/h Performance ratings available for all pool areas Variable equipment design permits individual configuration of empty and filter chambers, doors, sound absorbers, service openings and the like Easy cleaning, servicing, and inspection due to equipment design with completely smooth inner surfaces and hinges and sash fasteners that lie outside the airflow Deliverable in various corrosion protection classes Cold-bridge-free design with quality components</p> <p>PR-2009-0061-GB Subject to modification Version 02/2009</p> <p>3</p> <p>Performance diversity</p> <p>Performance ratings for all pool sizes and air volumes up to 45,000 m3/h</p> <p>GEA CAIRfricostar &gt; Modular, powerful, and energy-efficient</p> <p>[For pool areas of up to 1,000 m2] [Up to 45,000 m3/h air volume flow] [RLT hygiene according to VDI 6022] [Dehumidification capacity up to 310 kg/ h]For every individual requirement in swimming pool climate control</p> <p>GEA CAIRfricostar units have a performance range of 750 to maximum 45,000 m3/h. Swimming pools with pool areas up to 1,000 m 2 can be dehumidified with a single unit. In the performance model family which works with air velocities of about 2 m/s in the clearance cross-section, the largest unit can supply up to 36,000 m3 air per hour, in the standard version even 45,000 m3 at 2.8 m/s. The units achieve dehumidification capacity of up to 310 kg/h. The hygiene standard of the entire range of models according to VDI 6022 even conforms to applications in hospitals and rehabilitation centres.</p> <p>4</p> <p>PR-2009-0061-GB Subject to modification Version 02/2009</p> <p>Unit distribution according to air volume flow and water surfacesCAM 320 CAM 290 CAM 250 CAM 230 CAM 200 CAM 170Standard unit type 510 m2 435 m 380 m2 325 m2 260 m 195 m2 130 m 100 m2 85 m2 70 m2 60 m2 40 m22 2 2</p> <p>Standard series950 m2 850 m2</p> <p>745 m2 680 m 590 m22</p> <p>CAM 150 CAM 130 CAM 110 CAM 100 CAM 083 CAM 055 CAM 045 CAM 037 CAM 030 CAM 020 CAM 015 0</p> <p>Water surface max. (m2) Air temperature: 30 C Water temperature: 28 C</p> <p>5000</p> <p>10000</p> <p>15000</p> <p>20000</p> <p>250003</p> <p>30000</p> <p>35000</p> <p>40000</p> <p>45000</p> <p>50000</p> <p>Air volume flow (m / h)</p> <p>Unit distribution according to air volume flow and water surfacesCAM 360 CAM 320 CAM 290 CAM 250 CAM 230 CAM 200Performance unit type 460 m2 400 m2 340 m2 300 m2 250 m 230 m2 190 m2 130 m 100 m2 85 m2 70 m2 60 m2 35 m22 2</p> <p>Performance series830 m2 740 m2</p> <p>670 m2 575 m2 530 m2</p> <p>CAM 170 CAM 150 CAM 130 CAM 110 CAM 100 CAM 083 CAM 055 CAM 045 CAM 037 CAM 030 CAM 020 CAM 015 0</p> <p>Water surface max. (m2) Air temperature: 30 C Water temperature: 28 C</p> <p>5000</p> <p>10000</p> <p>15000</p> <p>20000Air volume flow (m3/ h)</p> <p>25000</p> <p>30000</p> <p>35000</p> <p>40000</p> <p>PR-2009-0061-GB Subject to modification Version 02/2009</p> <p>5</p> <p>GEA CAIRfricostar and GEA Fricostar Micro</p> <p>Construction and unit typeModular construction GEA CAIRfricostar air handling units with heat pump Unit types CAU, CAM, CMU, CMP, CPP Heat recovery with ECOSTAT POWER TUBE Heat pipe or ECOPLAT 2 POWER PLATE double-plate heat exchanger and additional heat pump circuit GEA CAIRfricostar air handling units without heat pump Unit types CWP, CWR Heat recovery without additional heat pump Compact construction GEA Fricostar Micro CAC with heat pump GEA Fricostar Micro CWC without heat pump Ready-to-install swimming pool hall climate-control units of compact design. Owing to smaller dimensions, they are especially suited for small private and public swimming pools. The features correspond to the modular units</p> <p>Construction Unit type Heat recovery Heat pump circuit Heat pipe technology ECOSTAT POWER TUBE Double-plate heat exchanger ECOPLAT 2 POWER PLATE Plate heat exchanger ECOPLAT POWER PLATE Method of operation Recirculated air Mixed air Air volume flow Minimum Maximum Series Standard Performance Control All-electronic DDC control Main use Private pools Pools with partial day operation (private, hotel, therapeutic baths) Private and public pools with small water surfaces and large hall volume Private and public pools of all kinds Public pools, swimming sport and recreational facilities m3/h m /h3</p> <p>CAU</p> <p>CAM</p> <p>GEA CAIRfricostar Modular CMU CMP CPP</p> <p>CWP</p> <p>CWR</p> <p>GEA Fricostar Micro Compact CAC CWC</p> <p>750 4100</p> <p>750 45000</p> <p>750 6200</p> <p>750 37500</p> <p>750 37500</p> <p>750 37500</p> <p>750 45000</p> <p>750 3600</p> <p>750 3600</p> <p>6</p> <p>PR-2009-0061-GB Subject to modification Version 02/2009</p> <p>Recirculated air dehumidification units with heat pumpStandard series Unit type CAU_SU1)</p> <p>GEA CAIRfricostar CAU</p> <p>015</p> <p>015</p> <p>025</p> <p>025</p> <p>030</p> <p>030</p> <p>037</p> <p>037</p> <p>Unit dimensions Width Height Length Air volume flow Minimum Maximum Rating for dehumidification Rating for ventilation Dehumidification capacity Recirculated-air operation Thermal capacity Air condenser without PWC operation Air condenser with PWC operation Pool water condenser After heater4) 3) 2)</p> <p>mm mm mm</p> <p>760 1120</p> <p>760 1120</p> <p>760</p> <p>760</p> <p>760</p> <p>760</p> <p>760</p> <p>760</p> <p>1360 1360 1800 1800</p> <p>1360 1360 1800 1880</p> <p>1600 1600 1720 1800</p> <p>1680 1680</p> <p>m3/h m /h3 3 3</p> <p>750 750 500</p> <p> 1842 1842 1228</p> <p>1842 </p> <p> 2755</p> <p>2755 </p> <p> 3355</p> <p>3354 </p> <p> 4129</p> <p>m /h m /h</p> <p>1842 2755 1228 1836</p> <p>2755 3355 1836 2236</p> <p>3354 4129 2236 2752</p> <p>kg/h</p> <p>3.1</p> <p>1.4</p> <p>4.2</p> <p>3.3</p> <p>4.3</p> <p>3.6</p> <p>4.9</p> <p>3.9</p> <p>kW kW kW kW</p> <p>7.0 4.6 2.3 5.9</p> <p>8.0 6.0 2.0 9.4</p> <p>13.0 10.6 2.5 11.1</p> <p>13.8 11.3 2.1 14.1</p> <p>16.2 13.3 2.6 14.1</p> <p>16.6 13.9 2.5 15.8</p> <p>19.8 16.3 3.3 18.3</p> <p>20.1 17.0 3.1 20.5</p> <p>All data are rounded values and merely serve for an overview. For exact data of the current configuration, use current GEA Air Treatment software.1) 2) 3) 4)</p> <p>Standard series = max. air velocity approx. 2.8 m/s Condition of hall air: 30C / 54% rel. hum. Pool water condenser (PWC) = accessory Feed / return temperature = 70C / 50C</p> <p>GEA CAIRfricostar CAU was primarily conceived for private swimming pools and is deliverable in four sizes as well as for an air volume flow of 750 to 4,100 m/h. The unit dehumidifies and heats the swimming pool in recirculated-air operation. It is delivered with an all-electronic control which automatically regulates the functions of the facility. In recirculated-air operation without dehumidification, the air in the swimming pool hall is circulated. When the target humidity is exceeded, the multi-function hygrostat installed in the hall switches the facility into dehumidification operation. The fan is then switched to level two and the refrigeration system for dehumidification is started. The dehumidification procedure runs until the target humidity is achieved, then the fan switches back to level one and the compressor in the dehumidifying plant stops. With an optional pool water condenser, a part of the obtained surplus energy from the heat pump circuit can be transferred to the pool water or an equivalent cycle.1</p> <p>Advantages of GEA CAIRfricostar CAU: Small investment expenditure Compact solution with small space requirements Electronic control</p> <p>1</p> <p>2</p> <p>Fan</p> <p>2</p> <p>Compressor</p> <p>Swimming pool operation with dehumidification requirement</p> <p>PR-2009-0061-GB Subject to modification Version 02/2009</p> <p>7</p> <p>GEA CAIRfricostar CAM</p> <p>Mixed air dehumidification unit with heat pump</p> <p>GEA CAIRfricostar CAM was conceived for private and public swimming pools of all kinds. The range of models is available with air volume flow of 750 to 46,000 m /h. The unit dehumidifies and heats the swimming pool3</p> <p>Advantages of CAIRfricostar CAM: Efficient and compact heat recovery Low investment, operation and maintenance costs Individually adaptable to all structural conditions Performance ratings for all pool areas</p> <p>hall in mixed air operating mode. Apart from a refrigeration system (heat pump), this unit type is additionally equipped with an efficient heat recovery (ECOSTAT POWER TUBE heat pipe). It is delivered with a DDC unit and controls all functions of the plant fully automatically.</p> <p>Standard series Unit type CAM_SU</p> <p>1)</p> <p>015</p> <p>025</p> <p>030</p> <p>037</p> <p>045</p> <p>055</p> <p>083</p> <p>100</p> <p>110</p> <p>130</p> <p>150</p> <p>170</p> <p>200</p> <p>230</p> <p>250</p> <p>320</p> <p>Unit dimensions Width Height Length mm mm mm 760 1120 760 760 760 1080 1080 1080 1400 1720 2000 1720 2000 2320 2640 2320 2920</p> <p>1360 1360 1600 1360 1600 2240 2240 2240 2320 2880 2960 2960 2960 3600 3600</p> <p>3000 3200 3300 3300 3300 3400 4000 4000 4000 4000 4400 4600 4600 4800 5000 5300</p> <p>Air volume flow Minimum Maximum Rating for dehumidification Rating for ventilation m3/h m /h3</p> <p>750</p> <p>1842 2755 3354 4128 5031 6192 9289 12385 15482 18191 20643 24256 28384 32513 40642</p> <p>1843 2756 3355 4129 5032 6193 9290 12386 15483 18192 20644 24257 28385 32514 35482 45128</p> <p>m3/h 1000 2000 3000 4000 5000 6000 9000 12000 15000 18000 20000 24000 27000 32500 34000 45000 m3/h 667 1333 2000 2667 3333 4000 6000 8000 10000 12000 13333 16000 18000 21667 22667 30000</p> <p>Dehumidification capacity Swimming pool operation (30% outs. air) kg/h 6 Standby operation (Recirculated air) kg/h VDI 20892)</p> <p>12 5 13</p> <p>16 5 19</p> <p>19 5 25</p> <p>26 9 32</p> <p>31 11 38</p> <p>43 12 57</p> <p>57 17 76</p> <p>72 21 95</p> <p>86 24 115</p> <p>98 31 127</p> <p>117 37 153</p> <p>135 45 172</p> <p>158 48 207</p> <p>169 58 216</p> <p>219 79 286</p> <p>3 6</p> <p>kg/h</p> <p>Thermal capacity Air condenser without PWC operation kW Air condenser with PWC operation kW Pool watercondenser 3) Heat recovery After heater4)</p> <p>5.4</p> <p>9.3</p> <p>10.7</p> <p>13.1</p> <p>17.3</p> <p>21.3</p> <p>26.9</p> <p>35.6</p> <p>42.4</p> <p>53.1</p> <p>62.6</p> <p>72.9</p> <p>87.8</p> <p>99.4 108.1 135.1</p> <p>3.0 2.4 3.0 9.9</p> <p>6.7 2.8 5.9 16.3</p> <p>7.9 3.0 6.9 20.6</p> <p>10.8 2.5 8.9 28.0</p> <p>14.5 2.6 12.2 35.9</p> <p>18.7 2.5 15.0 43.9</p> <p>22.5 4.3 22.0 66.5</p> <p>30.7 5.2 30.6</p> <p>39.0 4.6 39.3</p> <p>45.6 6.5 45.4</p> <p>55.7 8.2 50.8</p> <p>63.2 10.2 61.8</p> <p>77.1 10.2 72.5</p> <p>86.6 13.5 85.8</p> <p>95.4 118.5 14.2 15.7</p> <p>kW kW kW</p> <p>91.6 120.0</p> <p>88.8 110.0 135.9 147.3 180.1 188.2 232.4 237.6 327.3</p> <p>All data are rounded values and merely serve for an overview. For exact data of the current configuration, use GEA Air Treatment software.1) 2) 3) 4)</p> <p>Standard series = max. air velocity approx. 2.8 m/s Condition of hall air: 30C / 54%...</p>