swp series - lumitron lighting · swp wet location wall pack swp1 = 35 - 100w hps medium base 70 -...

7
405 S W P SWP SERIES Wet Location and General Duty Wall Pack UL 1598 Wet Locations CUL Enclosed & Gasketed

Upload: others

Post on 26-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SWP SERIES - Lumitron Lighting · SWP Wet Location Wall Pack SWP1 = 35 - 100W HPS Medium Base 70 - 100W MH Medium Base SWP2 = 70 - 150W HPS Medium Base 70 -175W MH Medium Base SWP3

405

SWP

SWP SERIESWet Location and General Duty Wall Pack

• UL 1598 Wet Locations

• CUL

• Enclosed & Gasketed

Page 2: SWP SERIES - Lumitron Lighting · SWP Wet Location Wall Pack SWP1 = 35 - 100W HPS Medium Base 70 - 100W MH Medium Base SWP2 = 70 - 150W HPS Medium Base 70 -175W MH Medium Base SWP3

406

Wet Location and General Duty Wall Pack

SWP SERIES

• UL1598WetLocations• Diecastaluminumhousing• Hingedrefractorframe• Continuoussiliconerubbergasket• Bronzeenamelfinishstandard •Customcolorsavailable-consultfactory•PolycarbonaterefractorstandardforSWP1series• Heatresistantborosilicateglassrefractor forSWP2,SWP3andSWP4

RIG-A-LITE

Page 3: SWP SERIES - Lumitron Lighting · SWP Wet Location Wall Pack SWP1 = 35 - 100W HPS Medium Base 70 - 100W MH Medium Base SWP2 = 70 - 150W HPS Medium Base 70 -175W MH Medium Base SWP3

w w w . r i g a l i t e . c o m

SWP SeriesUL 1598 Wet Locations • Die Cast Aluminum • Hinged Door • Silicone Gasket • CUL

407

HIGH PRESSURE SODIUM • METAL HALIDE

Catalog Number Logic

SWP1 2 3 4 5 6

Cataloglogicisforexplainingcatalognumberstructureonly.Notallcombinationsarepossible;consultfactoryforcatalognumbersnotlistedincharts.

BASIC SERIESSWPWetLocationWallPackSWP1 =35-100WHPSMediumBase 70-100WMHMediumBaseSWP2 =70-150WHPSMediumBase 70-175WMHMediumBaseSWP3 =250WHPS,MH&MogulBaseSWP4 =400WHPS,MH&MogulBase

LAMP CURRENT/LAMP WATTAGE03=35Watt05=50Watt07=70Watt10=100Watt15=150Watt17=175Watt25=250Watt40=400Watt

LAMP TYPES=HighPressureSodiumH=MetalHalide

BALLAST TYPER=Reactance,NormalPowerFactor(R)H=HighReactance,HighPowerFactorC=ConstantWattageAutotransformer HighPowerFactor(CWA-HPF)

BALLAST VOLTAGE04=Multi-Tap12=120V60HZ20=208V60HZ22=220/240V50HZ24=24V60HZ27=277V60HZ48=480V60HZ

OPTIONS1

PC=PhotoControlforAutomaticDusktoDawn (120VoltOnly)F=SingleFuse(120&277V)DF=DoubleFuse (208V,240V,280V60HZ&220/240V50HZ)TP=TamperProofScrewsFB=FuseBlockPR=PolycarbonateRefractors2

PS=PulseStart

1Consultfactoryforpricing.2StandardforSWP1Series,notavailablewithSWP2,SWP3 andSWP4Series.

1 5

62

3

4

Page 4: SWP SERIES - Lumitron Lighting · SWP Wet Location Wall Pack SWP1 = 35 - 100W HPS Medium Base 70 - 100W MH Medium Base SWP2 = 70 - 150W HPS Medium Base 70 -175W MH Medium Base SWP3

408

HIGH PRESSURE SODIUM • METAL HALIDE

SWP SeriesUL 1598 Wet Locations • Die Cast Aluminum • Hinged Door • Silicone Gasket • CUL

Basic Series Lamp Source Lamp Base Watt Ballast Type Voltage Catalog Number

SWP1 Medium 35 Reactor 120V SWP1-03-S-R-12*

Medium 50 Reactor 120V SWP1-05-S-R-12*

Medium 70 Reactor 120V SWP1-07-S-R-12*

Medium 100 Reactor 120V SWP1-10-S-R-12*

Medium 70 HX 120V SWP1-07-H-R-12*

Medium 100 HX 277V SWP1-10-H-H-27*

SWP2 Medium 70 HX 120V SWP2-07-S-H-12

Medium 100 HX 120V SWP2-10-S-H-12

Medium 100 Reactor 120V SWP2-10-S-R-12

Medium 150 Reactor 120V SWP2-15-S-R-12

Medium 150 HX 120V SWP2-15-S-H-12

Medium 150 CWA Multi-Tap SWP2-15-S-C-04

Medium 70 HX 120V SWP2-07-H-H-12

Medium 100 HX 120V SWP2-10-H-H-12

Medium 150 HX 120V SWP2-15-H-H-12

Medium *175 CWA Multi-Tap SWP2-17-H-C-04-PS

SWP3

HPS Mogul 250 CWA Multi-Tap SWP3-25-S-C-04

MH Mogul 250 CWA Multi-Tap SWP3-25-H-C-04-PS

SWP4

HPS Mogul 400 CWA Multi-Tap SWP4-40-S-C-04

MH Mogul 400 CWA Multi-Tap SWP4-40-H-C-04-PS

(Lamps included)

*120Vonly.Notavailablein277V.

HPS

MH

HPS

MH

RIG-A-LITE

Page 5: SWP SERIES - Lumitron Lighting · SWP Wet Location Wall Pack SWP1 = 35 - 100W HPS Medium Base 70 - 100W MH Medium Base SWP2 = 70 - 150W HPS Medium Base 70 -175W MH Medium Base SWP3

w w w . r i g a l i t e . c o m

SWP SeriesUL 1598 Wet Locations • Die Cast Aluminum • Hinged Door • Silicone Gasket • CUL

HIGH PRESSURE SODIUM • METAL HALIDE

409

UL 1598 Wet Locations • Die Cast Aluminum • Hinged Door • Silicone Gasket • CUL

Fixture Dimensions (inches)

SWP3 Series SWP4 Series

SWP1 Series SWP2 Series

9"

13"

9 3/8"

8 1/2"

7 1/4"7 "

9 "

17"

9"

17"

9 3/4 "123/4"

Accessories

StainlessSteelWireGuardforSWP2Series SWP2WG

StainlessSteelWireGuardforSWP3andSWP4Series SWP34WG

ClearPolycarbonateShieldforSWP2Series SWP2PS

ClearPolycarbonateShieldforSWP3andSWP4Series SWP34PS

Page 6: SWP SERIES - Lumitron Lighting · SWP Wet Location Wall Pack SWP1 = 35 - 100W HPS Medium Base 70 - 100W MH Medium Base SWP2 = 70 - 150W HPS Medium Base 70 -175W MH Medium Base SWP3

\NALLPACKListedFor Wet.Locations

iNSTALLATION INSTRUCTIONS.'. . ~,' 7 ; 0:.

IMPORTANT,READ CAREFULLYBEFORE INSTALLINGFIXTURE.RETAININSTRUCTIONS FOR FUTURE REFERENCE.

.' Wallpacks must be wired in accordance withthe Wallpacks are for outdoor use and should not beNationalElectricalCode and applicable local codes. used in areas _withlimnedventilationor high-ambieAt--Proper groum:tingis required for safety. temperatures. Installationshould be done by a quali-

fied electrician.

WARNING: Make certain power is OFF before installing or maintaining fixture.

LOCATIONRxture should be located on wall at least 18" be

any overhang or other struCtural detail. tioned with lamp in horizontal position.

MOUNTINGUse the drill and knock-out template on the insideback surface of the wallpack to match most standardrecessed junction boxes (see "A") or for more secure

installation, .Iag bolt backplat~ to mounting surfaceusing points "8".

o

1. Remove the lens and reflector.

2. Prepare the backplate for use by drilling or knock-ing out the appropriate holes.

3. Line up the backplate in desired location andmount securely.

4. Complete the wiring to the power source andground (see wiring instructions).

5. Replace the reflector, install the lamp and mountthe lens. .

6. !o insure weatherproof seal make sure aU holes(mounting, plugs; conduit, etc.) are sealed withweatherproof silicone seala~t. .

(over)

Page 7: SWP SERIES - Lumitron Lighting · SWP Wet Location Wall Pack SWP1 = 35 - 100W HPS Medium Base 70 - 100W MH Medium Base SWP2 = 70 - 150W HPS Medium Base 70 -175W MH Medium Base SWP3

WALL-=-ACK

INSTALLATION INSTRUCTIONS(continued)

WIRINGUnits built for a specific voltage are factory-wired.Make sure the supply voltage is compatible with theunit. Multi tap units may be used with a chqice of120v, 208v, 240v and 277v, provided that propertransformer leads are connected in the field.

1. Connect the appropriate voltage black fixture leadto the black supply lead. . .

. 2. Connect the white fixture lead to white supply lead.

3. Fixture ground screw must be connected to supplyground.

4. All unused leads must be capped and insulated.

BLACK BLACK

WHITE WHITE LIGHTFIXTURE

GROUND

PHOTOEYE INSTALLATIONA photoeye control may installed in the field.1. Remove lens and reflector2. Remove-closeup-plug-ontop-of fixture.3. Install Photoeye as per diagram.

RE-LAMPINGCaution: Prior to installing, check that the lamp is of proper type and wattage. Observe lamp manufacturer'srecommendationson lamp operation, ballast type ahd burning positions. .

1.Disconnectpower. 4. Openlensbyswillging door to the left, letting hinge2. Make sure fixture and lamp are cool enough to touch. hold lens.3. Loosen two screws holding lens frame. 5. Replace lamp.

6. Close lens and re-install screws.

IIISUPPLY

~CHING WIRE GUARDWire guard is attached over the glass refractor bymeans of the self-tapping screws (not supplied).

CLEANINGCaution: Be sure fixture temperature is cool enoughto touch. Be sure power is off.

Clean Reflector and lens with a cloth moistened with

non abrasive glass cleanin.g solution.

TROUBLESHOOTING CHECKLISTCheck that:1. Proper lamp is installed. Lamp is not faulty.2. Line voltage at the fixture is proper.

3. Fixture is wired properly4. Fixture is grounded properly.

THESE INSTRUCTIONS DO NOT COVER ALL DETAilS ORVARIATIONSIN EOUIPMENT. NOR DO THEY PROVIDE FOREVERY POSSIBLE CONTINGENCY TO BE MET IN CONNEC-TION WITH INSTALLATION,OPERATION OR MAINTENANCE

r-- RED {J BLACK

L

WHITE WHITE LIGHT.FIXTURE

- BlAeK - - - -\.-PHOTOEYE