swv a4 brochure copy - thepoolandspashop.com.au€¦ · %% ls@[mra[spk ls@[mra[spk ls@[mra[spk...
TRANSCRIPT
!"##$%&'()*()$$+(,*$-".-
SUMMER WAVE
///0123345/6748469:23:10;<3062
Save Money with Efficient Running PerformanceMitsubishií s advanced Inverter Smart Technology delivers high performance heating, providing more heat within a shorter running time. The COP (Coefficient of Performance) is as high as an astounding 15.5! Save money on your power bills.
Whisper Quiet The Summerwave Full Inverter Heat Pump uses a twin rotary Mitsubishi DC inverter compressor and full inverter ventilation system and is whisper quite in comparison with a standard system. This system is so quiet, that it produces less sound than a normal conversation*. This means you can enjoy a quieter swimming environment while still maintaining a comfortable pool temperature.
="..()>,'($!"##$$%&'()*()$+(,*$-".-
70% higher COP than a Normal On/Off Heat Pump
*45.8 decibels at 1 meter.
TUV TestedOur units have been independently tested by TUV Rheinland Facilities meaning they really are energy efficient and whisper quiet (and not just because we say so!).
Warranty15 years Titanium Tubing, 5 years Compressor, 2 years Parts, 1 year On Site Labour.
10 20 30 40 50 60 70 80
Sound Lab
Whisper LibrarySummerwave Full Inverter Hair dryer
Washing machine
Normalconversation
FridgeQuiet bedroomat night
Normal breathing
dB(A)
Soft Start Safety FeatureThe soft start feature is designed to guarantee the safety of your houseí s electricity system. When the heat pump is turned on, the soft start reduces the immediate draw on your electricity supply. This results in a smoother energy �o w, placing less burden on your electricity supply and reducing the impact on lights and other household appliances.
Maximise Your Pool SeasonThe Summerwave Full Inverter Heat Pump is designed to operate efficiently in air temperatures as low as 7° C and as high as 43° C . Now you can enjoy your pool during the cooler months by heating the water, and in the hot months by cooling the water.
Full Premium ABS Cabinet ProtectionWith a Full Premium ABS (Acrylonitrile butadiene styrene) Cabinet, there is no need to add a roof or any other protection against water splash, rain or the harsh summer sun. ABS does not rust or crack in the heat. Rest assured the cabinet will not let your heat pump or swimming enjoyment down.
Silence Mode FeatureRun your heat pump more efficiently and save money with our Silence Mode feature. Once your ideal pool temperature is reached, switch to Silence Mode for a higher COP and operating efficiency.
Twin Rotary Mitsubishi DC Inverter Compressor
DC Brushless Fan Motor Low noise and low power consumption
Soft Starter To guarantee the safety of the house electricity system
Premium ABS Cabinet Unique looking and life time ant rusting
20% more energy saving Enjoy more silence Quicker heating
SUMMERWAVE FULL INVERTER HEAT PUMP PRODUCT SPECIFICATIOns
!"##$%& '()$ www.summerwaveheatpumps.com.au
!"#$%%"&'"'()$(*+"(,&(#$&-*&#),$&(.,)/(0(+$102(310&4")5(6"0)(7*%8(+,9,&:(,+(,&fl*"&#"'(3;(0%3,"&)()"%8"20)*2"<( (/*%,',);<(*+"($=(0(8$$1>+80(#$?"2<(&,:/)(),%"()"%8"20)*2"<(.,&'(=0#)$2<(8$$1>+80(1$#0),$&<(.0)"2(="0)*2"+(0&'(,=()/"(*&,)(,+(+.,)#/"'($ff($?"2&,:/)5(@AAB(C*+)201,0&(D.&"'5
E8"#,fi#0),$&+(+*3-"#)()$(#/0&:"(.,)/$*)(&$),#"5
ModelSummerwave
80FiSummerwave
100FiSummerwave
135FiSummerwave
175FiSummerwave
210FiSummerwave
270FiSummerwave
350Fi
Ambient 26 ° C Water 26 ° C in,
28 ° C out
F080#,);(GHIJ K5A L5K @M5M @N5M O@5A ON5M>ON5A MP5O
7$."2(Q&8*)(HI
@5@R @5RO O5O O5LM M5SK R5P S5R
F5D575 @R5NTN5A @P5MTS5L @P5RTS5R @P5PTP5L @P5OTP5N @P5MTS5O>@P5OTS5O @P5PTP5P
Ambient 35 ° C Water ° C in, 28 ° C out
F$$1,&:(F080#,);(GHIJ
M5L R5P S5O N5N L5K @O5@ @S5R
7$."2(Q&8*)(HI
@5O @5R O5@ O5S M5M M5L P5@P
Power Supply OOATORAU>PA69(E,&:1"(7/0+"
OOATORAU>PA69(E,&:1"(7/0+"
OOATORAU>PA69(E,&:1"(7/0+"
OOATORAU>PA69(E,&:1"(7/0+"
OOATORAU>PA69(E,&:1"(7/0+"
OOATORA?>PA69TR@PU>PA69
E,&:1"($2(M(7/0+"
R@PU>PA69M(7/0+"
Fuse CV7E @A0%8 @A0%8 @P0%8 OA0%8 OA0%8 OP0%8>L0%8 @O0%8
Water Flow W7V MM>SS PA>SS KM>@@S @AK>@R@ @MM>@SS @SS>OAA OAA>MAA
Fittings C*+)201,0& RA%%
Refrigerant D9$&"(X2,"&'1;
!R@AC
Soft Start !"?"2+"(F;#1"(Y"=2$+)
Z"+
Unit Dimensions (mm)
%% LS@[MRA[SPK LS@[MRA[SPK LS@[MRA[SPK LS@[ROA[SPK LS@[ROA[NPK @ALO[ROA[LPK @@S@[PMA[LPK
Unit Weight 4: RP RL PO SM SK LA>LM @@N
Noise at 1 m at low/high speed
'\GCJ MK5KTRK5O MK5STRL5L R@5MTPR5A RM5@TPM5K RA5LTPR5O RM5PTPR5L RO5STPR5N
Noise at 10m '\GCJ @K5KTOK5O @K5STOL5L O@5MTMR OM5@TMO5K OA5LTMR5O OM5PTMR5L OO5STMR5N
Compressor Type
].,&(!$)02;(VQ]E^\QE6Q(YF(,&?"2)"2
Heat Exchanger F$,1"'(],)0&,*%(,&(7UF
Operating Temperature
TN(_(F()$(`RM(_(F
size:120x50mm