symphony plus life.ppt€¦ · · 2015-04-25hpg800 or brc400 modules ... bulk import / export...
TRANSCRIPT
S h Pl U d tJim Day, System Technology Consultant, Power Generation Group
Symphony Plus Update
© ABB Month DD, YYYY | Slide 2
BRC400/HPG800
Transferring to Limited Lifecycle 12/2013 Transferring to Limited Lifecycle 12/2013
Replaced by BRC410
PBA200 transitioning to Classic in 2013 PBA200 transitioning to Classic in 2013
Replaced by PBA800
RFO800 transitioning to Classic in 2013RFO800 transitioning to Classic in 2013
Replaced by RFO810
IOR800 transitioning to Classic in 2013O 800 t a s t o g to C ass c 0 3
Replaced by IOR810
Symphony PlusS+ Control & I/O Rack: BRC410S+ Control & I/O Rack: BRC410
Combines BRC400 controller power Combines BRC400 controller power with HPG800 device integration capabilities into one module
Current Firmware M 1 Current Firmware M_1 Form / fit / function upgrade for either
BRC400 or HPG800 Used in redundant configurations withUsed in redundant configurations with
HPG800 or BRC400 modules On-line upgrades of installed BRC400
and HPG800 possible through use of BRC410 i d d t iBRC410 in redundant pair
Composer – Symphony Plus Engineering
Version 5 0 3 Version 5.0.3
Classic in 2011
Limited life cycle 12/2013 Limited life cycle 12/2013
Version 5.1
Transitioning to Classic 12/2013Transitioning to Classic 12/2013
All versions replaced with Version 6e s o s ep aced t e s o 6
Symphony Plus – EngineeringComposer Harmony version 6 0Composer Harmony version 6.0
What’s new in version 6.0: New Microsoft Operating Systemsp g y
Windows 7 32Bit and 64Bit
Server 2008 32Bit and 64Bit
PNI800, HPC800, PDP800 Support
Integration with S+ Operations New Console Type (database)
From Composer launch S+ Operations faceplate
From S+ Operations launch Composer’s ‘View & Monitor’
New FC’s: 205 206 and 207 New FC s: 205, 206, and 207
Release of Composer System Ver. 1
Release of Composer Field Ver 1 Release of Composer Field Ver. 1
Symphony Plus – EngineeringComposer System version 1 0Composer System version 1.0
New Microsoft Operating Systems Windows 7 32Bit and 64Bit
Server 2008 32Bit and 64Bit Used for planning Symphony Plus
SystemsSystems Network Planning
Ethernet Switches P.C.’s
System Planning Launch Composer
Bulk Import / Export tool Bulk configurations
Centralized backup and restore
Symphony Plus – EngineeringComposer Field version 1 0Composer Field version 1.0
New Microsoft Operating Systems Windows 7 32Bit and 64Bit Server 2008 32Bit and 64Bit
Integrates Profibus and Hart with Composer
Supports commissioning of field devices
Status and Reporting to workstationp g
Import and Export Field Device Templates
Create Field Device Templates Create Field Device Templates
Bulk Data Interface of devices
Sync Harmony project with Field Devices
Harmony Gateway Software (HGS)
Version 5 0 Version 5.0
Classic in 2011, transitioned to limited in 2013
Version 5.1
Transitioning to Classic 12/2013
Replaced by version 6.0
10,000 modbus points
Support for HPC800
8 servers and 128 clients
Uses MS access 2007, must convert
Computer Interfaces
ICT03A ICT03A
Limited since 2006, replaced by ICT13A
ICT13A – does not support 64 bit OS ICT13A – does not support 64 bit OS
Transitioned to classic 2013, replaced by IET800
ICT12
Limited since 2007, replaced by IET800
Symphony Plus – Control and I/OINICI800: Ethernet CIUINICI800: Ethernet CIU
ICI800:ICI800: INFI-Net to Computer InterfaceICI800:ICI800: INFI Net to Computer Interface
Ethernet interface to INFI-Net used by Console & Tool applications
NIS21:NIS21: Network Interface module
IET800 requires NIS21
IET800: IET800: INFI-Net to Ethernet Transfer
Provides both 100 MB Ethernet & 19 2 to 115 2 KB Serial interfaces19.2 to 115.2 KB Serial interfaces
Supports up to 30,000 tags (Ethernet) and up to 5,000 tags
Supported by:
PPA,PPB , ConductorNT 6 4 S h + C 5 1 dsp4,Symphony+,Composer 5.1 and
newer,Harmony OPC
Symphony Plus IEB800: INFI Net to Ethernet BridgeIEB800: INFI-Net to Ethernet Bridge
30,000 tag across the bridge
Self configuring, no configuration required
Scheduled to be released 2nd qtr 2013
ConductorNT
Version 6 sp 4 Version 6 sp 4
Transitioning to Classic 12/2013
Microsoft end of life 2014 Microsoft end of life 2014 XP end of support April 8,2014
Replaced by Symphony Plus Operations or Process Portal A
Process Portal B
Version 2 SP 2 Version 2 SP 2
Classic in 2009
Transitioning to Limited 12/2013 Transitioning to Limited 12/2013 Microsoft end of life for OS 2014
XP end of support April 8,2014
Server 2003 end of support July 14,2015
Replaced by Symphony Plus Operations or Process Portal A
Symphony Plus Operations
Version 1 classic in 2013 Version 1 classic in 2013
Update to version 1.1
SP1 scheduled for 1st qtr 2013 SP1 scheduled for 1s qtr 2013 Adds integral SOE for HPC800
Version 2 scheduled end of 2nd qtr 2013q
Adds support for SPC600
Adds SMS pagingg g
Microsoft end of life for OS
Windows 7 SP1 1/14/2020
Server 2008 R2 std 1/14/2020
Symphony PlusS+ Control & I/O: HPC800S+ Control & I/O: HPC800
HPC800Based on field proven HPC800 HC800: Harmony Control Processor
Executes INFI 90 function codes BRC / HPG functionality
Based on field proven technology:• INFI 90 FC based• INFI 90 exception
reportingComposer tools BRC / HPG functionality
CP800: Communications Processor Control network interface to Ethernet
based plant network
• Composer tools enhanced with field device management capabilities
p Combination of NIS / NPM modules
Provides more than 30x the performance of previous generation INFI90 rack
t ll (MFP MFC t )controllers (MFPxx, MFCxx, etc.) Simultaneous support for Symphony Plus
I/O, Harmony Rack I/O, and S800 I/O 5 000 I/O ≤ 250 msec 5,000 I/O ≤ 250 msec Turbine control step change loop
response ≤ 25 msec
Symphony Plus S+ Control and I/O: HPC800 communicationsS+ Control and I/O: HPC800 communications
Plant Network (PN800)
PN800: S+ Plant Network (100 MB Ethernet TCP)
Plant Network (PN800) Connects consoles (S+ Operations) and
tools (S+ Engineering) to HPC800 controllers
“INFI-Net over Ethernet” 1,000 XR’s per second
(process value updates)M db TCP Modbus TCP Control integration of Modbus devices
such as Intelligent Electrical Devices (IED), 3rd party PLCs, Wireless HART ( ), p y ,devices
Up to 8 Servers & 128 Clients 500, 1500, 3000, 4000 or 10K Points
Peer-to-peer communications (CW800) 500 Bus Signal updates ≤ 50 msec
HN800 CW800
ModBus TCP (100 MB Ethernet)
Harmony I/O Network Controller PTP Network
Symphony PlusS+ Control & I/O: PDP800 PROFIBUS DPS+ Control & I/O: PDP800 PROFIBUS DP
HPC800 controller seamlessly integrates fieldHPC800 controller seamlessly integrates field devices through its PDP800 PROFIBUS interface module Profibus DP-V0, -V1 and -V2 Transmission rates from 9.6 Kbps to 12
Mbps Standard Profibus Diagnostic functions
SOE Ti St i ith S800 I/O th SOE Time-Stamping with S800 I/O or other devices that support this feature
Master & Line Redundancy Up to 64 Profibus Slaves per PDP800 Up to 64 Profibus Slaves per PDP800 Communicates to HPC800 Controller via
HN800 [Redundant] Up to 8 redundant PDP800’s can be p
connected to 1 HPC800
Symphony PlusS+ Control & I/O: HAI805 / HAO805 HART I/OS+ Control & I/O: HAI805 / HAO805 HART I/O
HART I/O Modules HART I/O Modules HAI805 – 8 Analog Inputs HAO805 – 8 Analog Outputs Dedicated HART modem for each Dedicated HART modem for each
I/O Channel Communicate to Controller via
[Redundant] HN800
Secondary /Tertiary HART variables: Variables available in Controller
( b d i t l t t )(can be used in control strategy) Update rates: less than 1 sec Up to 4 secondary/tertiary variables
per channel or deviceper channel or device
Symphony Plus S+ Control & I/O: PNI800 Communications InterfaceS+ Control & I/O: PNI800 Communications Interface
PNI800PNI800: PNI800PNI800: Computer Interface to PN800 CIU for PN800 S+ Plant Network
Preserves current SW interface Preserves current SW interface for existing Composer Harmony & S+ Operations applications!O i d f h HMI d One required for each HMI and one for every 10 engineering consoles
MB805MB805: Single Module Base
Module mounting base for PNI800 modules
Symphony Plus S+ Control & I/O:S+ Control & I/O:
Symphony PlusS+ Control and I/O: SPC600S+ Control and I/O: SPC600
CPU options for: User programs User programs Data memory Processing speeds
Two serial interfaces integrated for programming g p g gand communication
Optional CPU with integrated Ethernet Up to four communication modules Distributed and local I/O expansion Libraries with technology functions (e.g.
PLCopen)Environmental packaging for harsh environments Environmental packaging for harsh environments Extended operating temperature, immunity to
vibration and hazardous gases, use at high altitudes, etc.
P i i IEC61131 5 l Programming using IEC61131-5 language Program using C
Scalable optionsScalable options
Preliminary Info
Symphony PlusS+ Control and I/O: SPC600S+ Control and I/O: SPC600
Integrated communication Ethernet or ARCNET Ethernet or ARCNET MODBUS RTU CS31 (2-wire connection) ASCII ASCII
Fieldbus independent interface for slave communication PROFIBUS DP, CANopen, DeviceNet
With additional communication modules as master or multi-master (up to 4) Ethernet with switch PROFIBUS DP (V0/V1), DeviceNet,
CANopen RCOM
Serial interface for free protocol MODBUS Serial interface for free protocol, MODBUS, CS31, or ASCII
Real-time Ethernet: EtherCAT, PROFINET PROFINET SafetyPROFINET Safety
Preliminary Info
Symphony PlusS+ Control and I/O: SPC600S+ Control and I/O: SPC600
Simple connection toSimple connection to intelligent field devices
S600 I/O
Motor-Starter
Circuit Breakers
Wireless I/O & sensors
Soft-StarterVariable Speed Drives
Preliminary Info
Symphony PlusS+ Control and I/O: SPC600S+ Control and I/O: SPC600
Onboard Ethernet (optional):
• Programming via PC
• Internet protocols (web server, FTP, e-mail, time sync, and more)
Terminal base:
• Easy snap-on of CPU and optional communication modules
• CPU performance upgrade is
• IEC 60870-5-104
COM2 (Sub-D9, RS-232 / RS485)p pgconvenient and fast
• Pre-wiring of CPU connections
C i ti d l
( )
• Programming via PC
• ASCII protocol
• Modbus-RTU (master or slave)
Communication module:
• Up to 4 communication modules in any combination
COM1 (spring terminal, RS-232 / RS485)
P i i PC• Programming via PC
• CS31 bus (master)
• ASCII protocol
• Modbus-RTU (master or slave)
Preliminary Info