sysmex cs 5100

4
Design and specifications may be subject to change due to further product development. Sysmex Europe GmbH, Bornbarch 1, 22848 Norderstedt, Germany, Phone: +49 (40) 527 26 0, Fax: +49 (40) 527 26 100 www.sysmex-europe.com 1 CS-5100 * Exceptional throughput of up to 400 tests per hour with gold standard results * Efficient and productive, with remote access and LAS compatible * Superior calibration and assay performance * Pre analytical sample integrity check (HIL) * Powerful multi-wavelength technology - clotting, chromogenic, immunological and platelet aggregation methods CS-5100 Simply, safely and speedily - outstanding coagulation analysis The CS-5100 is a superb coagulation analyser. With a throughput of up to 400 tests per hour, it delivers high quality results in a very short timeframe. With its powerful multi-wavelength technology, it has 20 channels for clotting, chromogenic and immunoassays and eight for platelet aggregation with automatic stirring. The device also checks automatically for interfering substances (HIL) and can be run in random access with other assays. We have also focused on making the device easy to use, flexible and productive for you. Pre-analytical sample checks mean you no longer need to check manually, it offers remote access and it is easy include in larger laboratory solutions. Advanced reagent management makes use of simplified software, and an auto QC on vial change significantly diminishes the risk of errors. A great device, easy to use and as accurate as they come. No compromise on quality Using four different detection technologies, the CS-5100 delivers great quality analyses. With clotting, chromogenic, immunoturbimetric and platelet aggregation assays it delivers accuracy and precision for all parameters. Clotting method The CS-5100 uses the Optical Detection Method to detect the change in turbidity of the sample-reaction mixture during the coagulation process. This is reflected in the change in scattered light intensity when fibrinogen is converted into a fibrin mesh. Light strikes the reaction mixture, after the scattered light intensity is received by a photodiode. This converts the light intensity into electrical signals and is used to find the coagulation time. This method is used to measure prothrombin time, APTT, fibrinogen, factors and many other clotting tests. Chromogenic method Light with a wavelength of 405 nm passes through the sample and reagent mixture and reaches a photodiode, where the transmitted light is converted into electrical signals. The change in the intensity of this transmitted light is used to determine the change in absorbance. This measurement is used for chromogenic assays like Antithrombin and Protein C where a chromogenic substrate in presence of an activator causes the reagent mixture to change colour. Immunoassay and platelet aggregation method The sample-reagent mixture contains artificial particles that can aggregate when there is an antigen-antibody reaction

Upload: katamba-rogers

Post on 13-Dec-2015

22 views

Category:

Documents


2 download

DESCRIPTION

sytem

TRANSCRIPT

Page 1: Sysmex CS 5100

Design and specifications may be subject to change due to further product development.Sysmex Europe GmbH, Bornbarch 1, 22848 Norderstedt, Germany, Phone: +49 (40) 527 26 0, Fax: +49 (40) 527 26 100

www.sysmex-europe.com

1

CS-5100 * Exceptional throughput of up to 400 tests per hour with gold standard results * Efficient and productive, with remote access and LAS compatible * Superior calibration and assay performance * Pre analytical sample integrity check (HIL) * Powerful multi-wavelength technology - clotting, chromogenic, immunological and platelet aggregationmethods

CS-5100 Simply, safely and speedily - outstanding coagulationanalysis

The CS-5100 is a superb coagulation analyser. With a throughput of up to 400 tests per hour, it delivers high qualityresults in a very short timeframe. With its powerful multi-wavelength technology, it has 20 channels for clotting,chromogenic and immunoassays and eight for platelet aggregation with automatic stirring. The device also checksautomatically for interfering substances (HIL) and can be run in random access with other assays.We have also focused on making the device easy to use, flexible and productive for you. Pre-analytical sample checksmean you no longer need to check manually, it offers remote access and it is easy include in larger laboratory solutions.Advanced reagent management makes use of simplified software, and an auto QC on vial change significantlydiminishes the risk of errors. A great device, easy to use and as accurate as they come.

No compromise on qualityUsing four different detection technologies, the CS-5100 delivers great quality analyses. With clotting, chromogenic,immunoturbimetric and platelet aggregation assays it delivers accuracy and precision for all parameters.

Clotting method

The CS-5100 uses the Optical Detection Method to detect the change in turbidity of the sample-reaction mixture duringthe coagulation process. This is reflected in the change in scattered light intensity when fibrinogen is converted into afibrin mesh. Light strikes the reaction mixture, after the scattered light intensity is received by a photodiode. This convertsthe light intensity into electrical signals and is used to find the coagulation time. This method is used to measureprothrombin time, APTT, fibrinogen, factors and many other clotting tests.

Chromogenic method

Light with a wavelength of 405 nm passes through the sample and reagent mixture and reaches a photodiode, wherethe transmitted light is converted into electrical signals. The change in the intensity of this transmitted light is used todetermine the change in absorbance. This measurement is used for chromogenic assays like Antithrombin and ProteinC where a chromogenic substrate in presence of an activator causes the reagent mixture to change colour.

Immunoassay and platelet aggregation methodThe sample-reagent mixture contains artificial particles that can aggregate when there is an antigen-antibody reaction

Page 2: Sysmex CS 5100

Design and specifications may be subject to change due to further product development.Sysmex Europe GmbH, Bornbarch 1, 22848 Norderstedt, Germany, Phone: +49 (40) 527 26 0, Fax: +49 (40) 527 26 100

www.sysmex-europe.com

2

or particles that have a natural capability to aggregate like platelets. The mixture is exposed to light of a high wavelength,and the change in light absorbance caused by the formation of aggregates is detected as the change in transmittedlight. This is used for D-dimer assays and platelet aggregation assays (Von Willebrand activity, ADP, Collagen, ArachidonicAcid, Epinephrine).

Get it right before you start testing – pre-analytical sample integrity helpsPre-analytical issues can account for as much as 70% of a clinical laboratory’s errors. Multi-wavelength scanning andsample liquid-sensing technologies detect unsuitable specimens. A pre-analytical sample integrity check tests forinterfering substances in the sample – haemolysis, icterus, lipaemia – at three wavelengths: 405 nm, 575 nm and 660 nm.A primary tube sample volume check provides assistance by identifying potential inaccuracies caused by impropersample collection, which can result in an incorrect ratio of anticoagulant to patient plasma.Under specific conditions, the CS-5100 will automatically use the optimal wavelengths to ensure result accuracy in thepresence of hemolysis, icterus or lipemia. This minimises the need for retesting and helps you deliver the highest qualityresults on your first test run.

Multi-wave detection - reduce your repeat tests Using a multi-wave detection system, the CS-5100 can simultaneously measure multiple parameters using four differentmeasurement methods: coagulation, chromogenic, immunoassay and aggregation. The system’s photo-optical clotdetection means you have several advantages compared to mechanical detection.

* You can measure light transmittance over the entire course of clot formation, not just the end. * You can identify atypical reaction patterns easily and so determine the correct coagulation reaction result foryour patients with unusual in vitro clot reactions such as sepsis and DIC. * The clotting reactions display the complete clot signature, not just a single data point, so that you get far moredetailed test information and therefore better clinical utility.

Used on a single platform, the broad range of assays allows high test throughput – up to 400 samples per hour.

Cooled reagent system – flexible and cost-efficientIn the CS-5100, we have critically addressed the usability of our coagulation analysers – based on extensive input fromusers and our own knowhow. One of the results is our new, cooled reagent system with secure, in-situ barcode reading.Reagent racks are now placed in a double-ring reagent table capable of handling a total of 40 reagent bottles maintainedat 10°C. The bottles are slightly tilted to reduce dead volume and reagent waste and maximize the number of tests pervial.One position on each reagent rack can stir reagents so that you can use reagents that require continuous mixing.A separate reagent rack system lets you group reagents for each rack and for high sample loads - up to three vials ofthe same reagent. With a onboard capacity of 1000 cuvettes this delivers a long walk-away time . To reduce the risk oferrors, there is an optional automatic quality control when vials are changed.

Superior calibration and assay performance * Convenient batch change with maximum security

Page 3: Sysmex CS 5100

Design and specifications may be subject to change due to further product development.Sysmex Europe GmbH, Bornbarch 1, 22848 Norderstedt, Germany, Phone: +49 (40) 527 26 0, Fax: +49 (40) 527 26 100

www.sysmex-europe.com

3

* Accessibility for all users with standardized decision-making * Excellent linearity negating multiple calibrations for different assay ranges * Up to 12 dilution points for each calibration performed * Up to 10 live calibration curves per assay * Automatic recognition of the appropriate calibration curve.

SpecificationsDetection principles multi-wavelength detector for transmitted light at340, 405, 575, 660 and 800 nm Detection methods 20 channels for clotting, chromogenic and immunoassays8 channels for platelet aggregation Parameters up to 60 parameters can be analysed simultaneously Throughput up to 400 tests/h Samplingrack type, auto sampler, cap piercing functionality, initial capacity for 10 racks with 10 sampletubes each, continuous loading possibility, separate STAT positionsdirect sampling (optional) to connect the CS-5100 via its left side to a lab automation transportsystem Reagent holder 40 positions cooled at 10 °C5 positions at room temperatureall positions with positive reagent identification Reference curves multi-lot management with max. 10 curves/reagent lotand max. 10 reagent lots/parameter Quality controlx-bar, Levey-Jennings and Westgard control750 parameter files with max. 1,200 data points each Data storage up to 10,000 samples Dimensions/weightsmain unit*

Page 4: Sysmex CS 5100

Design and specifications may be subject to change due to further product development.Sysmex Europe GmbH, Bornbarch 1, 22848 Norderstedt, Germany, Phone: +49 (40) 527 26 0, Fax: +49 (40) 527 26 100

www.sysmex-europe.com

4

IPU with cabinetw x h x d [mm] / [kg]approx. 1030 x 1280 x 1150 / 278approx. 500 x 920 x 890 / 67*excluding optional features, such as direct sampling, which will alter the dimensions.