system limits
DESCRIPTION
System Limits. 1. Control facilities CCU Wireless 245 addresses max. Max. 150 Wireless Discussion Units Max. 93 Interpreter desks Max. 2 DDI’s (Intercom Operator and Ambient Mic) - PowerPoint PPT PresentationTRANSCRIPT
1 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
System Limits
1. Control facilities CCU Wireless 245 addresses max.
Max. 150 Wireless Discussion Units Max. 93 Interpreter desks Max. 2 DDI’s (Intercom Operator and Ambient Mic)
Channel selectors are passive units and using one reserved address for all. Reserved addresses are not a part of the 245!
2. Power handling Capacity Central Control Unit 130 Watt Extension Power Supply 255 Watt
3. DCN Cable length After 100 meter of system cable the signal needs to be regenerated.
Units with the regenerating signal-outlets: Trunk Splitter & Trunk Splitter protected Extension power supply
The number of serial tap-off connections from the Wireless CCU to the last tap-off in a branch must not exceed 4.
250 meter max. from the Wireless CCU to the last unit in the trunk.
I&U Instructions
2 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Power Consumption in Watt (DCN part)
Dual Delegate Interface 4.5 W Inclusive all connected FM panels.
Interpreter’s Desk 3.6 W
Channel selector unit 0.9 W
Data distribution unit 2.0 W
Extension Power Supply 0.8 W
Trunk Splitter 1.3 W
Trunk Splitter Protected 1.4 W
Watt value includes the 2 meter (6.5 ft.) unit-cable.
3 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Wireless Access Point4.0 W
Audio Expander Analogue 7.6 W
Audio Expander Digital 6.0 W
Cobra net interface10.5 W
Optical Network splitter 3.9 W
Fiber Interface (POF/GOF or GOF/POF) 4.6 W
Power Consumption in Watt (Optical part)
I&U Instructions
4 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Trunk Tap-off
Power handling capacities
Central Control Unit Extension Power Supply
65 W 65 W
65 W 65 W
130 W
65 W
85 W 85 W
255 W
85 W
I&U Instructions
5 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Max. number of units within 100M from CCU
Max. per trunk: 18 Interpreter desks
Max. all trunks: 36 Interpreter desks
Central Control Unit
Cable length per outlet to the last unit 100M
1 n 18
I&U Instructions
6 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Max. number of units within 100M from EPS
Max. per trunk: 23 Interpreter desks
Max. all trunks: 69 Interpreter desks
Trunk Tap-off
Cable length per outlet to the last unit 100M
Extension Power Supply
1 n 23
I&U Instructions
7 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Trunk Outlet & Tap-Off Outlets
For Trunk-cable splitting with regenerating the digital signal.
*
Tap-off outlets which regenerating the digital signal.Tap-off outlets which regenerating the digital signal.
* *
Extension Power Supply
* *
Trunk-in Trunk-outTrunk Splitter
Trunk SplitterProtected
I&U Instructions
8 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Using the Trunk Splitter Protected
* *
* Tap-off outlets with a limitation of 4,5 Watt.Tap-off outlets with a limitation of 4,5 Watt.
I&U Instructions
9 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Tap-Off Limitations
Trunk Splitter
Tap-off
Tap-off Trunk-lineLoop Through
Trunk-line
1st Tap-off
1st Tap-off
3rd Tap-off
2nd Tap-off
2nd Tap-off
3rd Tap-off
4th Tap-off
4th Tap-off
5th Tap-off
Extension Power SupplyCentral ControlUnit
I&U Instructions
10 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Maximum Cable Lengths 250M
Central ControlUnit
RegenerativeTap-offTrunk Splitter
ExtensionPower Supply
RegenerativeTap-offTrunk Splitter
ExtensionPower Supply
I&U Instructions
11 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
The length of cable used in a system hasa direct influence on the load of a
system.
The second in- line trunk- splitter has two extension cables connected to it, with lengths of 20 m and 50 m.
When determining the cable length of a Trunk-outlet or Tap-off outlet, the longest extension cable only is taken in to account.
Therefore, the total extension cable lengthfrom a single Trunk-outlet of the CCU is calculated as 10+50= 60 m (196.8 ft.)
Longest Extension Cable example
10 m (32.8 ft.)
50 m (164 ft.)20 m (65.6 ft.)
Central ControlUnit
I&U Instructions
12 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Power calculation Example-1
TrunkOutlet
Longest ExtensionCable length
Power consumptionwithout
ext. cable correction
Power consumption with
ext. cable correction
1 65 m. (213.2 ft.) 46.6 Watt 63.9 Watt
2 40 m. (147.4 ft.) 54.0 Watt 64.8 Watt
Total power in use 128.7 Watt
Central Control Unit
10x 5x
40m.1 2
13 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Power calculation Example-2
TrunkOutlet
Longest ExtensionCable length
Power consumptionwithout
ext. cable correction
Power consumption with
ext. cable correction
3 60 m. (196.8 ft.) 63.4 Watt 84.5 Watt
4 40 m. (131.2 ft.) 70.6 Watt 84.7 Watt
5 35 m. (131.2 ft.) 72.0 Watt 84.3 Watt
Total power in use 253.5 Watt
Trunk Tap-off
Extension Power Supply
10x35m.
10x
3 4 5
14 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Cable correction graph
I&U Instructions
15 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Fiber Interface
The fiber interface is used to: convert from plastic optical fiber
(POF) cable to glass optical fiber (GOF) cable and vice versa.
cover distances of more than 50 m in the optical network.
I&U Instructions
16 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Nodes Cable lengths graph
I&U Instructions
17 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Coverage Area Wireless Access Point
The maximum coverage area of the wireless access point is dependent upon its power.
18 DCNW Tech SD Design CalcST/PRM3-EU | |23.Nov.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
How to Design and Calculate a system
End of section