system overview - cooledge lighting · system overview 1 tile interior 2 tile interior corner kit...
TRANSCRIPT
™
™
COOLEDGE TILE INTERIOR - SPECIFICATIONS
PSD-0001-R01-102517 1/6
PROJECT REFERENCE TYPE
SPECIFIED BY QUANTITY
DATE NOTE For Luminous Surfaces
SYSTEM OVERVIEW
1 TILE Interior
2 TILE Interior Corner Kit (optional)
3 TILE Interior Cut-out Kit (optional)
4 TILE Interior Connector Kit
5 TILE Interior Starter Cable
6 LED Driver
Create luminous ceilings, feature walls, and large graphics displays with Cooledge TILE Interior products
Included: TILE Interior Installation Kit (TACC-INT-INST)
Also available: Extension Cables (TCBL-INT-LNG-10/20)
GENERAL
Location Indoor, dry location only
Operating Temp. 0-40°C (32-104°F)
Storage Temp. -40-85°C (-40-185°F)
Relative Humidity 90% max (non-condensing)
Operating Voltage 58 VDC
Electrical Connections Tool-less snap connectors
Base Material Flexible PET
SPECIFICATION
UL Listed lighting system inclusive of flexible light emitting sheets, connectors, low voltage cables, and LED drivers. Light output from the system must be +/- 10% of 600/300/150 lumens/sqft across the total illuminated area post-installation. Color Rendering Index (CRI) must be >90 and color consistency between light sheets must be typical 2 SDCM. Electrical connections between light emitting sheets and between cables and light emitting sheets must be tool-less and allow more than one connect/disconnect iteration. System must be configurable on-site and include the capability to accommodate obstacles, angles, and curves. System warranty must be a minimum of 5 years.
FEATURES
― Three choices of constant lumen output ensure consistent highly calibrated illumination
― Color consistency of typically 2 SDCM between TILEs meets stringent requirements for large area installations
― Cut-to-fit means systems are adaptable to any size installation and can accommodate obstacles and shapes
― Constant voltage electrical architecture is fully scalable without loss of performance or need to reconfigure drivers
― Low setback distances, flexibility, and no requirement for a heat sink enable optimal integration into luminous surfaces
― Multiple options for dimming, lumens, and CCT offer the most adaptable illumination for large surface areas available today
― Mounts directly to most common non-conductive construction materials (eg. drywall, plywood)
Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s continuing product improvement program.
™
COOLEDGE TILE INTERIOR - SPECIFICATIONS
PSD-0001-R01-102517 2/6
PHOTOMETRICS1
Light Output (lm) - per TILE 600, 300, 150
Correlated Color Temperature (CCT)
2700K, 3000K, 3500K, 4000K, 5700K
Color Rendering Index (CRI) ≥ 90
Color Uniformity 2 SDCM (typical)
Lumen Maintenance2 L80 = 75,000hr
1 Photometric files available from cooledgelighting.com
2 Based on LM80 data & TM-21 calculations
CCT Rf Rg
2700K 88 97
3000K 88 97
3500K 87 96
4000K 87 96
5700K 90 100
IESNA TM-30-15 DATA
POWER CERTIFICATIONS
WARRANTY
Light Output (lm) CCT Power (W)
600
2700K 5.4
3000K 5.4
3500K 5.0
4000K 5.0
5700K 5.0
300
2700K 2.8
3000K 2.8
3500K 2.5
4000K 2.5
5700K 2.4
150
2700K 1.4
3000K 1.4
3500K 1.3
4000K 1.3
5700K 1.2
EN 60598 Compliant (as a system)
55 YEAR SYSTEM WARRANTY
5 YE
AR SYSTEM WARRANTY
5 Year Limited Warranty:
Parts and workmanship when
used with a Cooledge approved
power supply.
E354088 E354088
E354088
E35408858VDC
E354088LISTED
Tc
55 YE
AR WARRANTY
5 YEAR WARRANTY
™
™
In Canada, TILE Interior must be installed within an enclosure
™
COOLEDGE TILE INTERIOR - SPECIFICATIONS
PSD-0001-R01-102517 3/6
TILE INTERIOR1
9.4”
7”4.
6”2.
2”11.7”
TILE INTERIOR CORNER KIT2
12”
Purpose: Cut-to-fit in corners where a full TILE does not fit in the space; or to step cut along angles and curves at the edge of a luminous surface (optional depending upon layout).
― (1) Corner TILE
― (1) Connector strip 2’ (610mm)
― (4) Single jumper
― (1) Double jumper (long)
TILE - INT - - - WHT
PRODUCTTILE
TYPEINT = Interior
FLUX600 = 600lm300 = 300lm150 = 150lm
CCT27 = 2700K30 = 3000K35 = 3500K40 = 4000K57 = 5700K
FINISHWHT = White
Example: TILE-INT-600-40-WHTHOW TO ORDER
TACC - INT - COR - -
PRODUCTTACC = TILE Accessory
TYPEINT = Interior
KITCOR = Corner Kit
FLUX600 = 600lm300 = 300lm150 = 150lm
CCT27 = 2700K30 = 3000K35 = 3500K40 = 4000K57 = 5700K
Example: TACC-INT-COR-300-35HOW TO ORDER
INCLUDED
™
COOLEDGE TILE INTERIOR - SPECIFICATIONS
PSD-0001-R01-102517 4/6
TILE INTERIOR CUT-OUT KIT3
Cut to fit around
obstacle
Jumper Connection
(Input missing)
Jumper Connection
(Output missing)
― (1) Cut-out TILE
― (1) Single Jumper (long)
TACC - INT - CUT - -
PRODUCTTACC = TILE Accessory
TYPEINT = Interior
KITCUT = Cut-out Kit
FLUX600 = 600lm300 = 300lm150 = 150lm
CCT27 = 2700K30 = 3000K35 = 3500K40 = 4000K57 = 5700K
Example: TACC-INT-CUT-300-35HOW TO ORDER
Purpose: Cut-to-fit around obstacles located in the middle of a luminous surface such as standoffs, support cables/rods, beams, pipes, etc. (optional depending on layout).
2.4”
2.4”
2.4”
2.4”
2.4”
2.4”
2.4” 2.4” 2.4” 2.4”
INCLUDED
™
COOLEDGE TILE INTERIOR - SPECIFICATIONS
PSD-0001-R01-102517 5/6
TILE INTERIOR CONNECTOR KIT4
Purpose: Makes the electrical connection to the first TILE in each run. Connects to two TILE runs and may be connected to additional connector strips (required).
TILE INTERIOR STARTER CABLE5
Purpose: Makes the electrical connection between the LED driver and the connector strips that deliver power to the TILEs (required).
TACC - INT - CON
PRODUCTTACC = TILE Accessory
TYPEINT = Interior
KITCON = Connector Kit
Example: TACC-INT-CONHOW TO ORDER
TCBL - INT - STR
PRODUCTTCBL = TILE Cable
TYPEINT = Interior
KITSTR = Starter Cable
Example: TCBL-INT-STRHOW TO ORDER
― (1) Connector Strip (2’ length)
― (4) Single Jumper
― (1) Double Jumper
Length = 10’
INCLUDED
™
COOLEDGE TILE INTERIOR - SPECIFICATIONS
PSD-0001-R01-102517 6/6
LED DRIVERS6
ADDITIONAL ACCESSORIES
MODEL TYPE OUTPUT POWER (W)INPUT
VOLTAGE (VAC)OUTPUT
VOLTAGE (VDC)DIMMING
EPSS Constant Voltage 90 NOM. 120-277 58 No
EPSD Constant Voltage 90 NOM. 120-277 58 0-10V
Purpose: Convert AC mains (line) power to safe, low voltage DC power. Cooledge LED drivers are offered with a range of dimming options (required).
cUL LISTED DRIVERS - INTERIOR
Detailed specifications for Cooledge LED drivers with ordering codes and dimming options are available in the following documents:
― Cooledge UL Listed LED Drivers - Specifications
EXTENSION CABLES
Purpose: Cable between TILE Starter Cable and LED Driver that extends the distance of the driver may be remotely located away from the TILEs. Please consult Cooledge for additional information including requirements for plenum rated cables.
― 16 AWG cable (non-plenum rated)
― Available in 10’ & 20’ lengths
PROTOCOL CONVERTERS
Purpose: A device that converts control signals from a DALI or DMX controller to 0/1-10V signals to operate Cooledge LED drivers. One converter may be used to control many LED drivers. Please consult Cooledge for the best option for your project.
― DALI — 0/1-10V
― DMX— 0/1-10V
Starter Cable
Crimp Connector
Extension Cable
~
CONNECTOR STRIP
TO TILES
CRIMPCONNECTOR
STARTERCABLE
DRIVER
BLACK
LINE
(SUPPLIED BY OTHERS)
NEUTRAL
EARTH
WHITE
VIOLET
GREY
RED
BLACKEXTENSION CABLE
IF REQUIRED
WIRENUT
PROTOCOLCONVERTER
CONTROLLER
GREEN/YELLOW
ELECTRICAL ENCLOSURE
LED Driver