systems manual - usg boral...- 64mm steel c-studs @ 600mm ctrs - 20mm or 36mm gap between c-studs...

8
www.usgboral.com INTRWALL ® INTERTENANCY SOLUTIONS SYSTEMS MANUAL NEW ZEALAND PB206/2 FEBRUARY 2017 Quality ISO 9001

Upload: others

Post on 20-Mar-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SYSTEMS MANUAL - USG Boral...- 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier - Insulation (refer to table) Fire Barrier: - 2x25mm Shaftliner between

www.usgboral.com

INTRWALL® INTERTENANCY SOLUTIONS

SYSTEMS MANUALNEW ZEALAND

PB206/2 FEBRUARY 2017

Quality ISO 9001

Page 2: SYSTEMS MANUAL - USG Boral...- 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier - Insulation (refer to table) Fire Barrier: - 2x25mm Shaftliner between

2 FEBRUARY 2017 | INTRWALL SYSTEMS MANUAL NZ

INTRWALL

ACOUSTIC RATINGS BASIS: RT&A TE405-05F20

SYSTEM LINING SIDE 1

LINING SIDE 2

NOM WALL WIDTH (GAP)

mmINSULATION* Rw Rw+Ctr

IW60.1A1x13mm

SHEETROCK BRAND STANDARD

1x13mm SHEETROCK

BRAND STANDARD161 (20) 75G11, 75P14

(stud cavity) 55 46

IW60.1D 1x13mm MULTISTOP

1x13mm MULTISTOP 177 (36) 90G11, 90P14

(stud cavity) 60 51

IW60.1E 1x13mm MULTISTOP

1x13mm SHEETROCK

BRAND STANDARD177 (36) 90G11, 90P14

(stud cavity) 59 51

IW60.1H 1x13mm FIBEROCK

1x13mm FIBEROCK 171 (36) 90G11, 90P14

(stud cavity) 61 53

IW60.1I 1x13mm FIBEROCK

1x13mm SHEETROCK

BRAND STANDARD177 (36) 90G11, 90P14

(stud cavity) 60 52

IW60.1K 1x13mm FIBEROCK

1x13mm MULTISTOP 177 (36) 90G11, 90P14

(stud cavity) 61 53

SYSTEM DESCRIPTIONSide 1: - Non fire resistant lining (refer to table) - 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier

- Insulation (refer to table)Fire Barrier: - 2x25mm Shaftliner between 51mm I-studs @ 600mm ctrs

Side 2: - Non fire resistant lining direct fixed to I-studs.

IW60.1FIRE RESISTANCE RATING

NLB -/60/60FROM BOTH SIDES

* 75/90G11 – 75/90mm 11kg/m3 glasswool Insulation. 75/90P14 – 75/90mm Polyester Insulation 14kg/m3

FRR Basis: FCO-2660, WFRA 40970, WFRA 41038, FCO-2256

For the full range of USG Boral systems refer to usgboral.com

Check product availability when specifying Multistop linings.

Page 3: SYSTEMS MANUAL - USG Boral...- 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier - Insulation (refer to table) Fire Barrier: - 2x25mm Shaftliner between

3INTRWALL SYSTEMS MANUAL NZ | FEBRUARY 2017

INTRWALL

ACOUSTIC RATINGS BASIS: RT&A TE405-05F20

SYSTEM LINING SIDE 1

LINING SIDE 2

NOM WALL WIDTH (GAP)

mmINSULATION* Rw Rw+Ctr

IW60.3A1x13mm

SHEETROCK BRAND STANDARD

1x13mm SHEETROCK

BRAND STANDARD220 (20) 75G11, 75P14

(both cavities) 55 40

IW60.3D 1x13mm MULTISTOP

1x13mm MULTISTOP 251 (36) 90G11, 90P14

(both cavities) 67 52

IW60.3E 1x13mm MULTISTOP

1x13mm SHEETROCK

BRAND STANDARD220 (20) 75G11, 75P14

(both cavities) 59 44

IW60.3H 1x13mm FIBEROCK

1x13mm FIBEROCK 251 (36) 90G11, 90P14

(both cavities) 65 50

IW60.3I 1x13mm FIBEROCK

1x13mm SHEETROCK

BRAND STANDARD220 (20) 75G11, 75P14

(both cavities) 58 43

IW60.3K 1x13mm FIBEROCK

1x13mm MULTISTOP 251 (36) 90G11, 90P14

(both cavities) 67 52

SYSTEM DESCRIPTIONSide 1: - Non fire resistant lining (refer to table) - 64mm C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier

- Insulation (refer to table)Fire Barrier: - 1x25mm Shaftliner between 25mm H-studs @ 600mm ctrs

Side 2: - Non fire resistant lining (refer to table) - 64mm C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier

- Insulation (refer to table).

IW60.3FIRE RESISTANCE RATING

NLB -/60/60FROM BOTH SIDES

* 75/90G11 – 75/90mm 11kg/m3 glasswool Insulation. 75/90P14 – 75/90mm Polyester Insulation 14kg/m3

FRR Basis: FCO-2256

NOTES:

• Systems IW60.3 are not to be used for corridor walls unless approved by USG Boral.

• Penetrations in Shaftliner panels are not permitted.

• Contact USG Boral for further information.

For the full range of USG Boral systems refer to usgboral.com

Check product availability when specifying Multistop linings.

Page 4: SYSTEMS MANUAL - USG Boral...- 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier - Insulation (refer to table) Fire Barrier: - 2x25mm Shaftliner between

4 FEBRUARY 2017 | INTRWALL SYSTEMS MANUAL NZ

* 75G11 – 75mm 11kg/m3 glasswool Insulation. 75P14 – 75mm Polyester Insulation 14kg/m3

ACOUSTIC RATINGS BASIS: RT&A TE405-05F20

SYSTEM LINING SIDE 1

LINING SIDE 2

NOM WALL WIDTH

mmINSULATION Rw Rw+Ctr

IW90.1A Nil 1x13mm FIRESTOP 65 NA 36 33

IW90.1B Nil 1x13mm MULTISTOP 65 NA 36 33

ACOUSTIC RATINGS BASIS: RT&A TE405-05F20

SYSTEM LINING SIDE 1

LINING SIDE 2

NOM WALL WIDTH (GAP)

mmINSULATION* Rw Rw+Ctr

IW90.2A 1x13mm FIRESTOP Nil 150 (20) 75G11, 75P14

(stud cavity only) 57 48

IW90.2B 1x13mm MULTISTOP Nil 150 (20) 75G11, 75P14

(stud cavity only) 58 49

SYSTEM DESCRIPTIONSide 1: - Nil linings

Fire Barrier: - 2x25mm Shaftliner between 51mm I-studs @ 600mm ctrs

- IBS rod in top trackSide 2: - 1x13mm fire resistant pbd direct fixed to I-studs

SYSTEM DESCRIPTIONSide 1: - 1x 13mm fire resistant pbd - 64mm C-studs @ 600mm ctrs - 20mm gap between C-studs and fire barrier

- Insulation between studs (refer to table)Fire Barrier: - 2x25mm Shaftliner between 51mm I-studs @ 600mm ctrs

Side 2: - Nil linings.

IW90.1FIRE RESISTANCE RATING

NLB -/90/90FROM BOTH SIDES

IW90.2FIRE RESISTANCE RATING

NLB -/90/90FROM BOTH SIDES

INTRWALL

FRR Basis: FCO-2660, FSV 0883, EWFA 2724-00

FRR Basis: FCO-2660, FSV 0883, EWFA 2724-00

NOTES:

• Penetrations in Systems IW90.2 must be fire rated.

• Contact USG Boral for further information.

For the full range of USG Boral systems refer to usgboral.com

Check product availability when specifying Multistop linings.

Page 5: SYSTEMS MANUAL - USG Boral...- 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier - Insulation (refer to table) Fire Barrier: - 2x25mm Shaftliner between

5INTRWALL SYSTEMS MANUAL NZ | FEBRUARY 2017

ACOUSTIC RATINGS BASIS: RT&A TE405-05F20

SYSTEM LINING SIDE 1

LINING SIDE 2

NOM WALL WIDTH (GAP)

mmINSULATION* Rw Rw+Ctr

IW90.3A 1x13mm FIRESTOP

1x13mm FIRESTOP 160 (20) 75G11, 75P14

(stud cavity only) 59 50

IW90.3B 1x13mm MULTISTOP

1x13mm MULTISTOP 160 (20) 75G11, 75P14

(stud cavity only) 60 51

IW90.3C 1x13mm FIRESTOP

1x13mm MULTISTOP 160 (20) 75G11, 75P14

(stud cavity only) 59 50

SYSTEM DESCRIPTIONSide 1: - 1x 13mm fire resistant pbd - 64mm C-studs @ 600mm ctrs - 20mm gap between C-studs and fire barrier

- Insulation (refer to table)Fire Barrier: - 2x25mm Shaftliner between 51mm I-studs @ 600mm ctrs

Side 2: - 1x 13mm fire resistant pbd direct fixed to I-studs.

IW90.3FIRE RESISTANCE RATING

NLB -/90/90FROM BOTH SIDES

INTRWALL

* 75G11 – 75mm 11kg/m3 glasswool Insulation. 75P14 – 75mm Polyester Insulation 14kg/m3

FRR Basis: FCO-2660, FCO-2434, EWFA 2724-00

For the full range of USG Boral systems refer to usgboral.com

Check product availability when specifying Multistop linings.

Page 6: SYSTEMS MANUAL - USG Boral...- 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier - Insulation (refer to table) Fire Barrier: - 2x25mm Shaftliner between

6 FEBRUARY 2017 | INTRWALL SYSTEMS MANUAL NZ

INTRWALL

ACOUSTIC RATINGS BASIS: RT&A TE405-05F20

SYSTEM LINING SIDE 1

LINING SIDE 2

NOM WALL WIDTH (GAP)

mmINSULATION* Rw Rw+Ctr

IW90.4A1x13mm

SHEETROCK BRAND STANDARD

1x13mm SHEETROCK

BRAND STANDARD245 (20) 75G11, 75P14

(both cavities) 58 44

IW90.4D 1x13mm MULTISTOP

1x13mm MULTISTOP 245 (20) 75G11, 75P14

(both cavities) 66 51

IW90.4E 1x13mm MULTISTOP

1x13mm SHEETROCK

BRAND STANDARD277 (36) 90G11, 90P14

(both cavities) 66 52

IW90.4H 1x10mm FIBEROCK

1x10mm FIBEROCK 239 (20) 75G11, 75P14

(both cavities) 65 51

IW90.4I 1x10mm FIBEROCK

1x13mm SHEETROCK

BRAND STANDARD274 (36) 90G11, 90P14

(both cavities) 66 52

IW90.4K 1x10mm FIBEROCK

1x13mm MULTISTOP 242 (20) 75G11, 75P14

(both cavities) 67 53

SYSTEM DESCRIPTIONSide 1: - Non fire resistant lining (refer to table) - 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier

- Insulation (refer to table)Fire Barrier: - 2x25mm Shaftliner between 51mm I-studs @ 600mm ctrs

Side 2: - Non fire resistant lining (refer to table) - 64mm C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier

- Insulation (refer to table).

IW90.4FIRE RESISTANCE RATING

NLB -/90/90FROM BOTH SIDES

* 75/90G11 – 75/90mm 11kg/m3 glasswool Insulation. 75/90P14 – 75/90mm Polyester Insulation 14kg/m3

FRR Basis: WFRA 40970, FSV 0883

For the full range of USG Boral systems refer to usgboral.com

Check product availability when specifying Multistop linings.

Page 7: SYSTEMS MANUAL - USG Boral...- 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier - Insulation (refer to table) Fire Barrier: - 2x25mm Shaftliner between

7INTRWALL SYSTEMS MANUAL NZ | FEBRUARY 2017

ACOUSTIC RATINGS BASIS: RT&A TE405-05F20

SYSTEM LINING SIDE 1

LINING SIDE 2

NOM WALL WIDTH (GAP)

mmINSULATION* Rw Rw+Ctr

IW120.1A 1x13mm FIRESTOP

1x13mm FIRESTOP 245 (20) 75G11, 75P14

(both cavities) 67 53

IW120.1B 1x13mm MULTISTOP

1x13mm MULTISTOP 245 (20) 75G11, 75P14

(both cavities) 69 55

IW120.1C 1x13mm FIRESTOP

1x13mm MULTISTOP 245 (20) 75G11, 75P14

(both cavities) 68 54

SYSTEM DESCRIPTIONSide 1: - 1x13mm fire resistant pbd - 64mm C-studs @ 600mm ctrs - 20mm gap between C-studs and fire barrier

- Insulation (refer to table)Fire Barrier: - 2x25mm Shaftliner between 51mm I-studs @ 600mm ctrs

Side 2: - 1x13mm fire resistant pbd - 64mm C-studs @ 600mm ctrs - 20mm gap between C-studs and fire barrier

- Insulation (refer to table).

IW120.1FIRE RESISTANCE RATING

NLB -/120/120FROM BOTH SIDES

* 75G11 – 75mm 11kg/m3 glasswool Insulation. 75P14 – 75mm Polyester Insulation 14kg/m3

FRR Basis: FCO-2434, EWFA 2724-00

INTRWALL

NOTES:

• Penetrations in Systems IW120.1 must be fire rated.

• Contact USG Boral for further information.

For the full range of USG Boral systems refer to usgboral.com

Check product availability when specifying Multistop linings.

Page 8: SYSTEMS MANUAL - USG Boral...- 64mm steel C-studs @ 600mm ctrs - 20mm or 36mm gap between C-studs and fire barrier - Insulation (refer to table) Fire Barrier: - 2x25mm Shaftliner between

SUSTAINABILITYUSG Boral aims to minimise the environmental impact of its operations and to make a positive difference to the environment and communities in which it operates. Plasterboard is manufactured from abundant natural gypsum resources and 100% recycled paper liner.

TECHNICAL ENQUIRIES 0800 USGBORAL FOR NZUSG Boral provides technical advice to Builders, Architects, Contractors, Engineers, Regulators and Home Owners throughout New Zealand.

Our friendly team can offer both practical and design input at all levels of the plasterboard industry. Get your next project off on the right track by contacting USG Boral weekdays 8.30am - 5.00pm on 0800 USGBORAL (0800 874 267).

HEALTH AND SAFETYFor information regarding the safe use of USG Boral Plasterboard products and accessories please refer to instructions on the product packaging or contact your local USG Boral Sales Office or TecASSIST® for a current copy of the Material Safety Data Sheet.

www.usgboral.com PB206/2 FEBRUARY 2017

This Technical Information Guide is intended to provide general information and should not be used as a substitute for professional advice. There are many variables that can influence construction projects which affect whether a particular construction technique is appropriate. Before proceeding with any project we recommend you obtain professional advice to ascertain the appropriate construction techniques to suit the particular circumstances of your project having regard to the contents of this Installation Manual. We recommend you use qualified tradespersons to install this system.

The technical information contained in this manual was correct at the time of printing. Building systems, details and product availability are, however, subject to change. To ensure the

information you are using is current, USG Boral recommends you review the latest building information available on the USG Boral website. For further information contact TecASSIST® or your nearest USG Boral Sales Office.

© 2015 USG BORAL. All rights reserved. The trademarks USG BORAL, INNOVATION INSPIRED BY YOU, Firestop, IntRwall, Wet Area, Multistop, Shaftliner, Firepack TecASSIST, are trademarks or registered trademarks of USG Boral Building Products or one or more of its affiliates. SHEETROCK, Fiberock, Aqua-Tough are trademarks or registered trademarks owned by United States Gypsum Company and used under license. Firesound is the trademark of H B Fuller. Pyropanel is the registered trademark of Pyropanel Developments Pty Ltd. Promaseal is the registered trademark of Promat.

SALES ENQUIRIES Auckland (09) 270-2595

Wellington (04) 560-4528

Christchurch (03) 365-4245