BB4 +48 CP-annn WORK AREA OUTLET. 4" X 4" BACKBOX WITH A SINGLE GANG MUDPLATE . STUB 3/4" CONDUIT TO AN ACCESSIBLE LOCATION ABOVE CEILING UNLESS OTHERWISE NOTED AND PROVIDE CABLING AS INDICATED BY ANNOTATION. PROVIDE FACEPLATE AND CABLE TERMINATION AS REQUIRED BY TYPE AND QUANTITY OF CABLES. COORDINATE FACEPLATE COLOR AND STYLE WITH ADJACENT ELECTRICAL RECEPTACLE FACEPLATES. PROVIDE MODULAR CABLE TERMINATIONS IN COLORS AS SPECIFIED, PROVIDE BLANKS FOR ALL EMPTY SPACES AND LABEL IN ACCORDANCE WITH OWNERS STRUCTURED WIRING LABELING SCHEME. UNLESS OTHERWISE NOTED, PROVIDE BLANK STAINLESS STEEL COVER PLATES ON EMPTY BACKBOXES. DRAWING SYMBOLS LEGEND xxxx-Dx CABLING ANNOTATIONS annng-xq } } } } E124-D2 EXAMPLES TWO CAT-6, 4pr, UTP DATA CABLES ROUTED FROM "DATA COLLECTION POINT E124" LOCATED IN EXISTING RENOVATED SPACE, CORRIDOR 124 WORK AREA OUTLET MOUNTED AT HEIGHT INDICATED. COORDINATE WITH CASEWORK AND/OR ADJACENT BACKBOXES (FOR EXAMPLE - RECEPTACLES) AND ADJUST HEIGHT AS REQUIRED. BRING DISCREPANCIES IN MOUNTING HEIGHT OF ADJACENT BACKBOXES TO THE ATTENTION OF OWNER & ENGINEER FOR RESOLUTION. REVISE HEIGHT/LOCATION TO DE-CONFLICT WITH EXIT SIGNAGE WHERE APPLICABLE ("+96" LOCATIONS). +48 +96 INSTALL BACKBOX 96" AFF (OR AFG). PROVIDE BLANK STAINLESS STEEL COVER AND ROUTE CONDUIT TO AN ACCESSIBLE SPACE ABOVE CEILING. PROVIDE BUSHING ON CONDUIT STUB. CAM WAP DATA OUTLET(S) LOCATED ABOVE CEILING FOR FUTURE USE AS INDICATED. PROVIDE SURFACE MOUNT HOUSING CONTAINING MODULAR INSERTS IN TYPES AND QUANTITIES AS INDICATED BY CABLING ANNOTATION. SECURE HOUSING TO STRUCTURAL ELEMENTS IN AN ACCESSIBLE, CONCEALED WHERE POSSIBLE, LOCATION. PROVIDE CABLING SERVICE LOOP AS NOTED TO ALLOW ADJUSTMENTS TO FINAL LOCATION. xxxxg-Dx E124C-D2 CAM - FUTURE IP VIDEO SURVEILLANCE CAMERA PROJ - FUTURE NETWORKED VIDEO PROJECTOR WAP - FUTURE WIRELESS ACCESS POINT USE/PURPOSE ANNOTATIONS TWO CAT-6, 4pr, UTP DATA CABLES ROUTED FROM DATA COLLECTION POINT E124 LOCATED IN EXISTING RENOVATED SPACE, ROOM 123. CABLES TERMINATED IN A SEPARATE GROUPING "C" WITHIN COLLECTION POINT PATCH PANEL. C161-F6 SIX STRAND FIBER OPTIC CABLE ROUTED FROM "DATA COLLECTION POINT C161" LOCATED IN EXISTING GYMNASIUM ROOM 161 CP CEILING MOUNTED DATA COLLECTION POINT. "ZONE ENCLOSURE" FOR CABLING TERMINATION, PATCHING AND ACTIVE EQUIPMENT AS SPECIFIED. ACTIVE NETWORKING EQUIPMENT (i.e. ETHERNET SWITCHES) IS NOT IN THIS CONTRACT (N.I.C.). CONTRACTOR SHALL PROVIDE AND INSTALL ENCLOSURE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. ENCLOSURE SHALL BE SUPPORTED FROM STRUCTURAL ELEMENTS AND SHALL INCLUDE A 120V, DUPLEX RECEPTACLE, PATCH PANELS AND ACCESSORIES AS REQUIRED FOR A FINISHED STRUCTURED CABLING INSTALLATION. PROVIDE BACKBONE CABLE AS INDICATED BY CABLING ANNOTATION. FREE STANDING TWO-POST EQUIPMENT RACK AS SPECIFIED. RACK INCLUDES ACCESSORIES AND DEVICES FOR POWER DISTRIBUTION, CABLING TERMINATION, PATCHING, WIRE MANAGEMENT- HORIZONTAL & VERTICAL; AND SHALL INCLUDE SPACE FOR FUTURE ACTIVE NETWORK EQUIPMENT. ACTIVE NETWORKING EQUIPMENT (i.e. ETHERNET SWITCHES) IS NOT IN THIS CONTRACT (N.I.C.). CONTRACTOR SHALL PROVIDE AND INSTALL RACK IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. RACK SHALL BE SECURELY BOLTED TO FLOOR AND SHALL INCLUDE MANUFACTURER'S LATERAL BRACING TO WALL OR STRUCTURE. annn-F x xxxxg-Dx FLOORBOX STYLE WORK AREA OUTLET. COORDINATE EXACT LOCATION WITH OWNER/ARCHITECT AND FURNITURE LAYOUT. COORDINATE WITH ELECTRICAL TRADES TO PROVIDE COMBINATION, OR COMPATIBLE, POWER/DATA BOXES WHERE POSSIBLE. SECOND FLOOR FLOORBOXES SHALL BE FIRE RATED POKE THROUGH TYPE EXCEPT WHERE USED WITH FLOOR TRENCHING. PROVIDE DATA CABLES AS INDICATED BY ANNOTATION. FIRST FLOOR BOXES SHALL BE PVC BOXES WITH SEPARATE CONDUITS FOR POWER AND DATA ROUTED TO THE NEAREST AVAILABLE WALL CAVITY AND ROUTED VERTICALLY TO AN ACCESSIBLE LOCATION. SPECIAL WORK AREA OUTLET MOUNTED AT HEIGHT INDICATED. PROVIDE BACKBOX AND CONDUIT AS NOTED. PROVIDE BLANK STAINLESS STEEL COVERS BB# +# BACKBOX, DEEP CAVITY, WITH BLANK COVER, BB2 = 4" WIIDE, BOX WITH SINGLE GANG (2x4) OPENING BB4 = 4" BOX WITH DOUBLE-GANG (4x4) OPENING +48 = MOUNT 48", UNLESS OTHERWISE NOTED "ABOVE FINISHED FLOOR" +6MB = MOUNT 6" ABOVE TOP EDGE OF MARKER BOARD +6C = MOUNT 6" ABOVE COUNTER GENERAL NOTES: 1. PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT EDITION OF THE NATIONAL ELECTRIC CODE AND TIA STANDARDS 568, 569, 606 AND 607. 2. EXISTING CONSTRUCTION/FINISHES DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AT LEAST EQUAL IN MATERIAL AND APPEARANCE TO THAT WHICH EXISTED BEFORE CONSTRUCTION BEGAN. 3. CONTRACTOR SHALL COORDINATE WITH OWNER ON FINAL LOCATION OF OWNER-PROVIDED EQUIPMENT, FINAL CABLE TRAY ROUTING, AND EXACT LOCATIONS FOR ALL EQUIPMENT NOTED AS "BY OTHERS," INCLUDING WIRELESS ACCESS POINT DROPS. 4. ROUTE INTERIOR CABLING CONCEALED ABOVE ACCESSIBLE CEILINGS AND SUPPORTED BY J-HOOKS UNTIL REACHING NEAREST CABLE TRAY. 5. WHERE EXPOSED, ALL CABLES SHALL BE PROTECTED BY STEEL CONDUIT OR VANDAL RESISTANT STEEL SURFACE MOUNT RACEWAY. 6. DOORWAYS INDICATED FOR ACCESS CONTROL POINT SHALL BE PREPARED FOR ACCESS CONTROL COMPONENTS e.g. CARD READER, DOOR CONTACT & POWER TRANSFER HINGE. SEE ARCHITECTURAL DOOR DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. 7. ALL OUTDOOR CABLING SHALL BE ENCLOSED WITHIN CONDUIT, MOUNTING HARDWARE, AND PROTECTED AGAINST VANDALISM, DAMAGE, AND UNAUTHORIZED ACCESS. ALL ENCLOSURES, HARDWARE AND FASTENING DEVICES SHALL BE VANDAL RESISTANT AND SECURED WITH STAINLESS STEEL FASTENERS. 8. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID TO DETERMINE EXISTING CONDITIONS FOR ROUTING OF NEW CABLES, CABLE LENGTHS AND TO DETERMINE QUANTITIES OF CONDUITS AND ACCESSORIES REQUIRED. 9. ALL ITEMS AND CABLING INSTALLED WITHOUT CONDUIT, OTHER THAN PATCH CABLING WITHIN A SINGLE ROOM, ENCLOSURE, OR EQUIPMENT, SHALL BE CMP (PLENUM RATED) AND LISTED FOR THE INTENDED USE. MODULAR JACK AND CABLING COLOR SCHEME STANDARDS DETERMINED BY OWNER WHITE COPPER BACKBONE AND/OR HORIZONTAL CABLE USED FOR ANALOG/DIGITAL SIGNALS OTHER THAN ETHERNET - SUCH AS FAX, MODEM, DIGITAL ALARM COMMUNICATORS, T1 OR DSL CIRCUITS . MODULAR JACK CABLE JACKET CABLING TYPE BLUE BLUE HORIZONTAL CAT-6 UTP STRUCTURED CABLING SYSTEM. WIRED DATA NETWORK YELLOW YELLOW HORIZONTAL CAT-6 UTP STRUCTURED CABLING SYSTEM INTENDED FOR WIRELESS ACCESS POINT CONNECTIONS. WIRELESS DATA NETWORK EQUIPMENT DROPS GREEN GREEN HORIZONTAL CAT-6 UTP STRUCTURED CABLING SYSTEM INTENDED FOR IP SURVEILLANCE CAMERA CONNECTION. CAMERA NETWORK DUPLEX RECEPTACLE COVER W/ CLOSEABLE LIDS DEVICE JACKS AND CABLING OF TYPE(S) INDICATED ENTIRE ASSEMBLY SHALL BE BY SINGLE MANUFACTURER AS SPECIFIED AND SHALL CONSIST OF ALL COMPONENTS, INCLUDING BACK BOX, ACTIVATION KIT, DIVIDERS, MODULAR FACEPLATES, AND COVER REQUIRED FOR A COMPLETE FINISHED INSTALLATION COMPATIBLE WITH THE FLOOR AND FINISH SCHEDULED FOR THE AREA WHERE LOCATED. POWER IN POWER/DATA SEPARATION 1" CONDUIT DATA IN 1" CONDUIT NOTE: POWER OUT DATA OUT 1" CONDUIT 1" CONDUIT SCALE: FLOORBOX DETAIL FOR FIRST FLOOR FLOORBOXES NONE T-001 1 PROVIDE IDENTIFYING COLOR AND LABEL (TYP) SINGLE GANG MODULAR FACEPLATE (TYP) SCALE: WORK AREA OUT - 1 DATA DROP SHOWN NONE T-001 2 MIN 3/4" EMT CONDUIT TO ABOVE CEILING (TYP) (BLANK) (BLANK) 2015 DESIGN ARCHITECTS, INC. ARNOLD, MO HILLSBORO, IL EAST ST. LOUIS, IL SPRINGFIELD, IL NEOSHO, MO 200 N. MARKET ST. MARION, IL 62959 F: 618.998.0076 PH: 618.998.0075 T-001

Upload: duongminh

Post on 16-Mar-2018

218 views

Category:

Documents


4 download

TRANSCRIPT

BB4 +48

CP-annn

WORK AREA OUTLET. 4" X 4" BACKBOX WITH A SINGLE GANG

MUDPLATE . STUB 3/4" CONDUIT TO AN ACCESSIBLE LOCATION ABOVE

CEILING UNLESS OTHERWISE NOTED AND PROVIDE CABLING AS

INDICATED BY ANNOTATION. PROVIDE FACEPLATE AND CABLE

TERMINATION AS REQUIRED BY TYPE AND QUANTITY OF CABLES.

COORDINATE FACEPLATE COLOR AND STYLE WITH ADJACENT

ELECTRICAL RECEPTACLE FACEPLATES. PROVIDE MODULAR CABLE

TERMINATIONS IN COLORS AS SPECIFIED, PROVIDE BLANKS FOR ALL

EMPTY SPACES AND LABEL IN ACCORDANCE WITH OWNERS

STRUCTURED WIRING LABELING SCHEME. UNLESS OTHERWISE

NOTED, PROVIDE BLANK STAINLESS STEEL COVER PLATES ON EMPTY

BACKBOXES.

DRAWING SYMBOLS LEGEND

xxxx-Dx

CABLING ANNOTATIONS

annng-xq

} }

}}

E124-D2

EXAMPLES

TWO CAT-6, 4pr, UTP DATA CABLES ROUTED FROM "DATA

COLLECTION POINT E124" LOCATED IN EXISTING RENOVATED

SPACE, CORRIDOR 124

WORK AREA OUTLET MOUNTED AT HEIGHT INDICATED. COORDINATE

WITH CASEWORK AND/OR ADJACENT BACKBOXES (FOR EXAMPLE -

RECEPTACLES) AND ADJUST HEIGHT AS REQUIRED. BRING

DISCREPANCIES IN MOUNTING HEIGHT OF ADJACENT BACKBOXES TO

THE ATTENTION OF OWNER & ENGINEER FOR RESOLUTION. REVISE

HEIGHT/LOCATION TO DE-CONFLICT WITH EXIT SIGNAGE WHERE

APPLICABLE ("+96" LOCATIONS).

+48 +96

INSTALL BACKBOX 96" AFF (OR AFG).

PROVIDE BLANK STAINLESS STEEL COVER

AND ROUTE CONDUIT TO AN ACCESSIBLE

SPACE ABOVE CEILING. PROVIDE BUSHING

ON CONDUIT STUB.

CAM

WAP

DATA OUTLET(S) LOCATED ABOVE CEILING FOR FUTURE USE AS

INDICATED. PROVIDE SURFACE MOUNT HOUSING CONTAINING

MODULAR INSERTS IN TYPES AND QUANTITIES AS INDICATED BY

CABLING ANNOTATION. SECURE HOUSING TO STRUCTURAL

ELEMENTS IN AN ACCESSIBLE, CONCEALED WHERE POSSIBLE,

LOCATION. PROVIDE CABLING SERVICE LOOP AS NOTED TO ALLOW

ADJUSTMENTS TO FINAL LOCATION.

xxxxg-Dx

E124C-D2

CAM - FUTURE IP VIDEO SURVEILLANCE CAMERA

PROJ - FUTURE NETWORKED VIDEO PROJECTOR

WAP - FUTURE WIRELESS ACCESS POINT

USE/PURPOSE ANNOTATIONS

TWO CAT-6, 4pr, UTP DATA CABLES ROUTED FROM DATA

COLLECTION POINT E124 LOCATED IN EXISTING

RENOVATED SPACE, ROOM 123. CABLES TERMINATED IN

A SEPARATE GROUPING "C" WITHIN COLLECTION POINT

PATCH PANEL.

C161-F6

SIX STRAND FIBER OPTIC CABLE ROUTED FROM "DATA

COLLECTION POINT C161" LOCATED IN EXISTING GYMNASIUM

ROOM 161

CP

CEILING MOUNTED DATA COLLECTION POINT. "ZONE ENCLOSURE"

FOR CABLING TERMINATION, PATCHING AND ACTIVE EQUIPMENT AS

SPECIFIED. ACTIVE NETWORKING EQUIPMENT (i.e. ETHERNET

SWITCHES) IS NOT IN THIS CONTRACT (N.I.C.). CONTRACTOR SHALL

PROVIDE AND INSTALL ENCLOSURE IN ACCORDANCE WITH

MANUFACTURERS RECOMMENDATIONS. ENCLOSURE SHALL BE

SUPPORTED FROM STRUCTURAL ELEMENTS AND SHALL INCLUDE A

120V, DUPLEX RECEPTACLE, PATCH PANELS AND ACCESSORIES AS

REQUIRED FOR A FINISHED STRUCTURED CABLING INSTALLATION.

PROVIDE BACKBONE CABLE AS INDICATED BY CABLING ANNOTATION.

FREE STANDING TWO-POST EQUIPMENT RACK AS SPECIFIED. RACK

INCLUDES ACCESSORIES AND DEVICES FOR POWER DISTRIBUTION,

CABLING TERMINATION, PATCHING, WIRE MANAGEMENT- HORIZONTAL

& VERTICAL; AND SHALL INCLUDE SPACE FOR FUTURE ACTIVE

NETWORK EQUIPMENT. ACTIVE NETWORKING EQUIPMENT (i.e.

ETHERNET SWITCHES) IS NOT IN THIS CONTRACT (N.I.C.).

CONTRACTOR SHALL PROVIDE AND INSTALL RACK IN ACCORDANCE

WITH MANUFACTURERS RECOMMENDATIONS. RACK SHALL BE

SECURELY BOLTED TO FLOOR AND SHALL INCLUDE MANUFACTURER'S

LATERAL BRACING TO WALL OR STRUCTURE.

annn-Fx

xxxxg-Dx

FLOORBOX STYLE WORK AREA OUTLET. COORDINATE EXACT

LOCATION WITH OWNER/ARCHITECT AND FURNITURE LAYOUT.

COORDINATE WITH ELECTRICAL TRADES TO PROVIDE COMBINATION,

OR COMPATIBLE, POWER/DATA BOXES WHERE POSSIBLE. SECOND

FLOOR FLOORBOXES SHALL BE FIRE RATED POKE THROUGH TYPE

EXCEPT WHERE USED WITH FLOOR TRENCHING. PROVIDE DATA

CABLES AS INDICATED BY ANNOTATION. FIRST FLOOR BOXES SHALL

BE PVC BOXES WITH SEPARATE CONDUITS FOR POWER AND DATA

ROUTED TO THE NEAREST AVAILABLE WALL CAVITY AND ROUTED

VERTICALLY TO AN ACCESSIBLE LOCATION.

SPECIAL WORK AREA OUTLET MOUNTED AT HEIGHT INDICATED.

PROVIDE BACKBOX AND CONDUIT AS NOTED. PROVIDE BLANK

STAINLESS STEEL COVERS

BB# +# BACKBOX, DEEP CAVITY, WITH BLANK COVER,

BB2 = 4" WIIDE, BOX WITH SINGLE GANG (2x4) OPENING

BB4 = 4" BOX WITH DOUBLE-GANG (4x4) OPENING

+48 = MOUNT 48", UNLESS OTHERWISE NOTED "ABOVE FINISHED FLOOR"

+6MB = MOUNT 6" ABOVE TOP EDGE OF MARKER BOARD

+6C = MOUNT 6" ABOVE COUNTER

GENERAL NOTES:

1. PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT EDITION OF THE NATIONAL

ELECTRIC CODE AND TIA STANDARDS 568, 569, 606 AND 607.

2. EXISTING CONSTRUCTION/FINISHES DISTURBED DURING CONSTRUCTION SHALL BE

RESTORED TO A CONDITION AT LEAST EQUAL IN MATERIAL AND APPEARANCE TO THAT

WHICH EXISTED BEFORE CONSTRUCTION BEGAN.

3. CONTRACTOR SHALL COORDINATE WITH OWNER ON FINAL LOCATION OF

OWNER-PROVIDED EQUIPMENT, FINAL CABLE TRAY ROUTING, AND EXACT LOCATIONS

FOR ALL EQUIPMENT NOTED AS "BY OTHERS," INCLUDING WIRELESS ACCESS POINT

DROPS.

4. ROUTE INTERIOR CABLING CONCEALED ABOVE ACCESSIBLE CEILINGS AND

SUPPORTED BY J-HOOKS UNTIL REACHING NEAREST CABLE TRAY.

5. WHERE EXPOSED, ALL CABLES SHALL BE PROTECTED BY STEEL CONDUIT OR VANDAL

RESISTANT STEEL SURFACE MOUNT RACEWAY.

6. DOORWAYS INDICATED FOR ACCESS CONTROL POINT SHALL BE PREPARED FOR

ACCESS CONTROL COMPONENTS e.g. CARD READER, DOOR CONTACT & POWER

TRANSFER HINGE. SEE ARCHITECTURAL DOOR DETAILS AND SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

7. ALL OUTDOOR CABLING SHALL BE ENCLOSED WITHIN CONDUIT, MOUNTING

HARDWARE, AND PROTECTED AGAINST VANDALISM, DAMAGE, AND UNAUTHORIZED

ACCESS. ALL ENCLOSURES, HARDWARE AND FASTENING DEVICES SHALL BE VANDAL

RESISTANT AND SECURED WITH STAINLESS STEEL FASTENERS.

8. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID TO

DETERMINE EXISTING CONDITIONS FOR ROUTING OF NEW CABLES, CABLE LENGTHS

AND TO DETERMINE QUANTITIES OF CONDUITS AND ACCESSORIES REQUIRED.

9. ALL ITEMS AND CABLING INSTALLED WITHOUT CONDUIT, OTHER THAN PATCH CABLING

WITHIN A SINGLE ROOM, ENCLOSURE, OR EQUIPMENT, SHALL BE CMP (PLENUM RATED)

AND LISTED FOR THE INTENDED USE.

MODULAR JACK AND CABLING COLOR SCHEME STANDARDS

DETERMINED BY OWNER WHITE COPPER BACKBONE AND/OR HORIZONTAL

CABLE USED FOR ANALOG/DIGITAL

SIGNALS OTHER THAN ETHERNET - SUCH

AS FAX, MODEM, DIGITAL ALARM

COMMUNICATORS, T1 OR DSL CIRCUITS .

MODULAR JACKCABLE JACKET

CABLING TYPE

BLUE BLUE HORIZONTAL CAT-6 UTP STRUCTURED

CABLING SYSTEM. WIRED DATA NETWORK

YELLOW YELLOW HORIZONTAL CAT-6 UTP STRUCTURED

CABLING SYSTEM INTENDED FOR WIRELESS

ACCESS POINT CONNECTIONS. WIRELESS

DATA NETWORK EQUIPMENT DROPS

GREEN GREEN HORIZONTAL CAT-6 UTP STRUCTURED CABLING

SYSTEM INTENDED FOR IP SURVEILLANCE

CAMERA CONNECTION. CAMERA NETWORK

DUPLEX

RECEPTACLE

COVER W/

CLOSEABLE

LIDS

DEVICE JACKS

AND CABLING

OF TYPE(S)

INDICATED

ENTIRE ASSEMBLY SHALL BE BY SINGLE MANUFACTURER AS SPECIFIED

AND SHALL CONSIST OF ALL COMPONENTS, INCLUDING BACK BOX,

ACTIVATION KIT, DIVIDERS, MODULAR FACEPLATES, AND COVER

REQUIRED FOR A COMPLETE FINISHED INSTALLATION COMPATIBLE WITH

THE FLOOR AND FINISH SCHEDULED FOR THE AREA WHERE LOCATED.

POWER IN

POWER/DATA

SEPARATION

1" CONDUIT

DATA IN

1" CONDUIT

NOTE:

POWER OUT

DATA OUT

1" CONDUIT

1" CONDUIT

SCALE:

FLOORBOX DETAIL FOR FIRST FLOOR FLOORBOXES

NONE

T-001

1

PROVIDE

IDENTIFYING

COLOR AND

LABEL (TYP)

SINGLE GANG

MODULAR

FACEPLATE

(TYP)

SCALE:

WORK AREA OUT - 1 DATA DROP SHOWN

NONE

T-001

2

MIN 3/4" EMT

CONDUIT TO

ABOVE

CEILING (TYP)

(BLANK)

(BLANK)

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-001

J

KEYED NOTES:

1. STUB CONDUITS UP ALONG WEST WALL OF ROOM "ELECTRICAL 135"

2. PROVIDE APPROXIMATELY 24" X 30" FIBER REINFORCED POLYMER CONCRETE HANDHOLE.

HAND HOLE SHALL BE FLUSH WITH GRADE OR SIDEWALK SURFACE.

3. PROVIDE 4' PVC CONDUIT OR HDPE DUCT 30" BELOW GRADE FOR FUTURE DATA AND/OR

SURVEILLANCE CABLES. RACEWAY SHALL CONTAIN PULL ROPE FOR FUTURE USE.

4. PROVIDE APPROXIMATELY 11' X17" FIBER REINFORCED POLYMER CONCRETE HAND HOLE.

INSTALL FLUSH WITH GROUND OR CONCRETE SURFACE

5. PROVIDE 4' PVC CONDUIT OR HDPE DUCT 30" BELOW GRADE FOR FIBER OPTIC LINK TO

SURVEILLANCE SYSTEM NETWORK NODE LOCATED IN POLE MOUNTED ENCLOSURE LOCATED

AS INDICATED BY KEYED NOTE NUMBER 6. SEE SPECIFICATION SECTIONS 27 13 43 AND 27 21 29

FOR ADDITIONAL INFORMATION.

6. PROVIDE WEATHERPROOF, NEMA 4 ENCLOSURE MOUNTED APPROXIMATELY 14' ABOVE

FINISHED GRADE. ENCLOSURE SHALL CONTAIN HARDENED ETHERNET SWITCH, POWER

SUPPLY AND FIBER TERMINATION PANELS AND OTHER ACCESSORIES AS REQUIRED. SEE

SPECIFICATION SECTIONS 27 13 43 AND 27 21 29 FOR ADDITIONAL INFORMATION.

7. PROVIDE EXTERIOR VIDEO SURVEILLANCE CAMERA AS SCHEDULED. PROVIDE MOUNTING

BRACKETS AS REQUIRED AND MAKE NETWORK CONNECTIONS TO EQUIPMENT INSIDE POLE

MOUNTED ENCLOSURE INDICATED BY KEYED NOTE NUMBER 6 ON THIS SHEET RACEWAY SHALL

ENTER ENCLOSURE FROM BOTTOM WHERE POSSIBLE.

8. EXISTING 2" PVC CONDUIT STUB FROM GREENHOUSE. EXTEND CONDUITS AS INDICATED BY

KEYED NOTE NUMBERS 9 AND 10.

9. PROVIDE 2" PVC CONDUIT 30" BELOW GRADE FOR FIBER OPTIC LINK TO GREENHOUSE

NETWORK NODE SEE SPECIFICATION SECTIONS 27 13 43 AND ONE LINE DIAGRAM ON SHEET

T-502 FOR ADDITIONAL INFORMATION. PROVIDE PULL ROPE FOR FUTURE USE.

10. PROVIDE 2" PVC CONDUIT 30" BELOW GRADE FOR USE AS REQUIRED BY FIRE ALARM SYSTEM

FOR IDC, SLC AND ANNUNCIATION CIRCUITRY. PROVIDE PULL ROPE FOR FUTURE USE.

#

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-100

SCALE:

NORTH

1" = 60'-0"

SYSTEMS SITE PLAN

UP

UP

DN

DN

Area A Area B

Area DArea C

EXG.

KEYPLAN

KEYED NOTES :

1. PROVIDE FLUSH MOUNTED, WEATHERPROOF, BACK BOX FOR NEW EXTERIOR

SURVEILLANCE CAMERA. SEE ADJACENT ELEVATION ANNOTATION. COORDINATE

EXACT HEIGHT AND LOCATION WITH OWNER AND LOCATION CONDITIONS. BACK

BOX SHALL INCLUDE A 3/4" CONDUIT ROUTED TO AN NEARBY INTERIOR

ACCESSIBLE LOCATION. BACK BOX SHALL INCLUDE A WEATHERPROOF COVER

PLATE WITH THREADED CONNECTION(S) FOR MINIMUM TWO FUTURE LFNC

(SEALTIGHT) CONNECTIONS.

2. PROVIDE CAT 6, 8P8C MODULAR (ETHERNET) JACK(S) AS INDICATED IN A SURFACE

MOUNT STYLE BOX ABOVE CEILING IN AN ACCESSIBLE, BUT CONCEALED, WHERE

POSSIBLE, LOCATION FOR NEW AND FUTURE NETWORK CONNECTED

SURVEILLANCE CAMERA(S). CONTRACTOR SHALL LEAVE 10' SERVICE LOOP(S)

NEATLY COILED, SECURED IN ACCESSIBLE LOCATION NEAR CONNECTOR.

3. COORDINATE WITH SURVEILLANCE SYSTEM TO PROVIDE BACK BOX AT EXACT

CAMERA LOCATION OR PROVIDE ACCESS PANEL IN HARD CEILING APPROXIMATELY

AS INDICATED WITH DATA CABLE TERMINATION AND TEN FOOT SERVICE LOCATED

ABOVE CEILING.

4. PROVIDE SURFACE MOUNTED RACEWAY AND FINISH STYLE BACK BOX ON

STRUCTURAL COLUMN AT APPROXIMATELY 9' AFF.

5. PROVIDE 4" EMT CONDUIT RACEWAY FOR DATA CABLING FROM INTERSTITIAL

SPACE ABOVE FIRST FLOOR CEILING TO "STORAGE 210 ON SECOND FLOOR AS

INDICATED. ALIGN HORIZONTAL STUBS WITH CABLE TRAY AND PROVIDE

BUSHINGS.

6. PROVIDE 4" EMT CONDUIT STUB THROUGH WALL FOR DATA CABLING. PROVIDE

BUSHINGS ON EACH END. PROVIDE FIRE STOP RATED PENETRATION DEVICE

WHERE REQUIRED.

7. PROVIDE 4" EMT CONDUIT ROUTED ABOVE CEILING AND WITHIN SOFFIT SPACE AS

INDICATED. PROVIDE PROVIDE PULL ROPE AND BUSHINGS ON EACH END.

FIRESTOP AS REQUIRED.

8. ROUTE CONDUIT(S) FROM DATA COLLECTION POINT F210 VERTICALLY INTO

INTERSTITIAL SPACE, TURN HORIZONTAL AND TERMINATE CONDUIT AT AN

ACCESSIBLE LOCATION. PROVIDE BUSHING ON CONDUIT END(S).

9. PROVIDE 4" CONDUIT BELOW GRADE FROM "STORAGE 120" LOCATED WITHIN

"KIDDIE CITY" AREA AND DATA COLLECTION POINT F210 LOCATED IN "STORAGE 210"

LOCATED ON SECOND FLOOR AS INDICATED ON SHEET T-105. CONDUIT ROUTES

BELOW BASEMENT ORCHESTRA PIT LEVEL AND ROUTES VERTICALLY WITHIN

CHASE AS INDICATED BY KEYED NOTE NUMBER 17.

10. PROVIDE 4" CONDUIT BELOW GRADE AS INDICATED.

11. TURN CONDUIT UP ALONG WALL TO A HEIGHT OF APPROXIMATELY 36" AND

PROVIDE BUSHINGS.

12. PROVIDE 2-1/2" CONDUIT BELOW GRADE AS INDICATED. PROVIDE PULL ROPE FOR

FUTURE CABLING. FOR FIRE ALARM, OR OTHER SYSTEMS AS REQUIRED.

13. PENETRATE WALL INTO ELEVATOR EQUIPMENT ROOM BELOW. SEAL PENETRATION

WITH ANNULAR SEAL FOR WATERTIGHT INSTALLATION.

14. ROUTE ONE 4-PAIR, CAT6 CABLE IN 1" CONDUIT BELOW GRADE TO ELEVATOR

EQUIPMENT ROOM LOCATED IN BASEMENT AS INDICATED ON SHEET T-105.

15. PROVIDE TWO REMOTE DOOR RELEASE BUTTONS; ONE EACH FOR DOORS 125A

AND 125B. COORDINATE EXACT LOCATION WITH OWNER AND CASEWORK IN

OFFICE 124.

16. PROVIDE 4" CONDUIT BELOW GRADE FOR EXTERIOR HAND HOLE AND FUTURE

CABLING. INCLUDE PULL ROPE.

17. ROUTE CONDUIT VERTICALLY TO A POINT WHERE IT TURN AND ENTER ROOM

"STORAGE 210" AT APPROXIMATELY 9' AFF FOR THAT ROOM.

18. PROVIDE APPROXIMATELY 11" X 17" POLYMER CONCRETE HAND HOLE WITH

GASKETED COVER LABELED "COMMUNICATIONS" .

19. NOT USED.

20. PROVIDE ACCESSORIES AND MAKE CONNECTIONS AS REQUIRED TO CONNECT

DOOR TO ACCESS CONTROL SYSTEM. PROVIDE RACEWAY AND BACK BOXES AS

REQUIRED TO ROUTE POWER AND DATA BUS TO ELECTRIC LOCKSET VIA POWER

TRANSFER HINGE. PROVIDE DOOR POSITION SENSOR AS REQUIRED.

21. COORDINATE WITH ELECTRICAL SHEETS TO PROVIDE FLOOR TRENCH AND FLOOR

BOXES WITH POWER AND DATA CONNECTIONS AS INDICATED.

22. ROUTE SEPARATE CONDUITS BELOW GRADE FOR POWER AND DATA CABLING.

ROUTE CONDUITS TO WALL APPROXIMATELY AS INDICATED AND TURN VERTICALL

TO A POINT ABOVE SUSPENDED CEILING, THE TURN HORIZONTAL AND STUB OUT

INTO INTERSTITIAL SPACE. DATA CONDUIT SHALL BE 2" MINIMUM, OR, MULTIPLE

SMALLER CONDUITS FOR EQUIVALENT CAPACITY.

23. PROVIDE APPROXIMATELY 14"X14" HANDHOLE. COORDINATE EXACT LOCATION

WITH SITE CONDITIONS AND OWNER.

24. ROUTE #4 TELECOMMUNICATION BONDING CONDUCTOR IN 1" CONDUIT BELOW

GRADE. CONDUCTOR ROUTES TO DATA COLLECTION POINT 210 LOCATED IN

STORAGE 207 (SEE RELATED KEYED NOTE NUMBER 18) VIA "JANITOR 103" AND

STORAGE 207".

25. DATA JACK AND WIRELESS ACCESS POINT TO BE PROVIDE UNDER RENOVATION

PHASE CONTRACT AND IS NOT INCLUDED IN THIS CONTRACT (NIC).

26. PROVIDE

3

4

" EMT CONDUIT CONCEALED ABOVE CEILING FOR SURVEILLANCE

CAMERA CABLING.

27. PROVIDE 1" EMT CONDUIT CONCEALED ABOVE CEILING FOR CONCESSION AREA

WORK AREA OUTLETS AND SURVEILLANCE CAMERA CABLING.

28. PROVIDE CAMERA AS SPECIFIED ALONG WITH A WALL MOUNT CAMERA BRACKET

AS REQUIRED AND INSTALL CAMERA AT A HEIGHT THAT OPTIMIZES CAMERA FIELD

OF VIEW.

29. PROVIDE 2" PVC CONDUIT BELOW GRADE FOR DATA, LIGHTING

CONTROLS, OR OTHER CIRCUITRY AS MAY BE REQUIRED BY

EQUIPMENT LOCATED AT DIRECTORS CHAIR LOCATION.

30. 2" ROUTE CONDUIT VERTICALLY WITHIN CHASE TO ACCESSIBLE

LOCATION IN STORAGE ROOM ON SECOND FLOOR ABOVE. THIS

CONDUIT PROVIDES PATH FOR PROJECTOR VIDEO CABLING AS

INDICATED ON SHEET T-105.

31. PROVIDE APPROXIMATELY 2' X 2' GASKETED HAND HOLE FOR DATA,

LIGHTING CONTROL AND OTHER CIRCUITRY AS MAY BE REQUIRED AT

DIRECTORS CHAIR LOCATION. COORDINATE EXACT LOCATION WITH

CASEWORK, ARCHITECT AND THEATER LIGHTING AND SOUND

CONTROLS VENDORS. PROVIDED GROMMETED OPENINGS IN LID AS

REQUIRED.

32. ROUTE CONDUITS UP TO STORAGE ROOM 207 DIRECTLY ABOVE.

ROUTE TO HEIGHT OF CABLE TRAY WITHIN ROOM 207 AND TERMINATE

WITH A BEND TO HORIZONTAL AND PROVIDE BUSHING.

33. PROVIDE TWO (2) 1-1/2" CONDUIT STUBS THROUGH WALL FOR CABLING

AS REQUIRED.

34. PROVIDE FLUSH MOUNTED WALL ENCLOSURE IN ORCHESTRA PIT AS

INDICATED ON SHEET E-105.

35. 2" ROUTE CONDUIT VERTICALLY WITHIN STAIRWELL OR CHASE TO

ACCESSIBLE LOCATION ON SECOND FLOOR ABOVE. THIS CONDUIT

PROVIDES PATH FOR LIGHTING CONTROL CABLING AS REQUIRED FOR

ROOM 203 LOCATED ON THE SECOND FLOOR ABOVE (AS INDICATED

ON SHEET T-105).

KEYED NOTES CONTINUED :

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-101

SCALE:

NORTH

1/8" = 1'-0"

AREA 'A' FIRST FLOOR RENOVATION PLAN

6 Sim

+5

4 (T

EL

)

+54 (TEL)

+54 (TEL)

+4

8

+4

8

+4

8

+4

8+

48

+4

8

+4

8

+4

8

CP-H105

+5

4 (T

EL

)

+86 CAM

+86 CAM

+54 (TEL)

+54 (TEL)

+5

4 (T

EL

)

+48

APPROX 11' AFG

APPROX

10' AFG

7

7

11

18

15

16

17

5

5

4

8

11

2

2

3

4

5

4

2

3

6

2

23

5

2

1

26

4

5

10

X

20

19

12

14

24

25

6

3

1

27

21

22

27

27

21

22

22

21

21

22

21

22

22

21

Area A Area B

Area DArea C

EXG.

KEYPLAN

KEYED NOTES :

1. PROVIDE FLUSH MOUNTED, WEATHERPROOF, BACK BOX

FOR NEW EXTERIOR SURVEILLANCE CAMERA. SEE

ADJACENT ELEVATION ANNOTATION. COORDINATE EXACT

HEIGHT AND LOCATION WITH OWNER AND LOCATION

CONDITIONS. BACK BOX SHALL INCLUDE A 3/4" CONDUIT

ROUTED TO AN NEARBY INTERIOR ACCESSIBLE LOCATION.

BACK BOX SHALL INCLUDE A WEATHERPROOF COVER

PLATE WITH THREADED CONNECTION(S) FOR MINIMUM TWO

FUTURE LFNC (SEALTIGHT) CONNECTIONS.

2. PROVIDE CAT 6, 8P8C MODULAR (ETHERNET) JACK(S) AS

INDICATED IN A SURFACE MOUNT STYLE BOX ABOVE

CEILING IN AN ACCESSIBLE, BUT CONCEALED, WHERE

POSSIBLE, LOCATION FOR NEW AND FUTURE NETWORK

CONNECTED SURVEILLANCE CAMERA(S). CONTRACTOR

SHALL LEAVE 10' SERVICE LOOP(S) NEATLY COILED,

SECURED IN ACCESSIBLE LOCATION NEAR CONNECTOR.

3. PROVIDE CAT6, 8P8C MODULAR (ETHERNET) JACK(S) AS

INDICATED IN A SURFACE MOUNT STYLE BOX ABOVE

CEILING IN AN ACCESSIBLE, BUT CONCEALED, WHERE

POSSIBLE, LOCATION FOR NEW AND FUTURE NETWORK

CONNECTED WIRELESS ACCESS POINT(S). CONTRACTOR

SHALL LEAVE 15' SERVICE LOOP(S) NEATLY COILED,

SECURED IN ACCESSIBLE LOCATION NEAR CONNECTOR

4. PROVIDE 24" X 48" CEILING MOUNTED ACTIVE NETWORKING

EQUIPMENT ENCLOSURE AS SPECIFIED. ENCLOSURE

SHALL ACT AS THE DATA COLLECTION POINT FOR ROOM(S)

AS INDICATED BY THE HOMERUN ANNOTATION ADJACENT

EACH WORK AREA OUTLET. ENCLOSURE SHALL CONTAIN

AND INCLUDE PATCH PANELS, WIRE MANAGEMENT

ACCESSORIES, COPPER AND FIBER TERMINATION ADAPTER

PLATES AS REQUIRED TO TERMINATE STRUCTURED WIRING

SYSTEM. ACTIVE NETWORKING EQUIPMENT SHALL BE

PROVIDED AS SPECIFIED. PROVIDE 120 VOLT BRANCH

CIRCUIT CONNECTION AS REQUIRED. SEE ELECTRICAL

SHEETS FOR ADDITIONAL INFORMATION. UNIT SHALL BE

SUPPORTED FROM STRUCTURAL BUILDING COMPONENTS

IN ACCORDANCE WITH MANUFACTURER

RECOMMENDATIONS AND IN ACCORDANCE WITH

INTERNATIONAL BUILDING CODE.

5. PROVIDE FIBER OPTIC BACKBONE CABLING AS INDICATED

AND SPECIFIED. CABLES SHALL BE ROUTED TO

COLLECTION POINT C161 LOCATED AS SHOWN IN DETAIL 1

ON SHEET T-104. SEE FIBER ONE-LINE FOR ADDITIONAL

INFORMATION.

6. PROVIDE 3" EMT CONDUIT ABOVE HARD CEILING AS

INDICATED.

7. PROVIDE 4" EMT CONDUIT ROUTED ABOVE CEILING AND

WITHIN SOFFIT SPACE AS INDICATED. PROVIDE PROVIDE

PULL ROPE AND BUSHINGS ON EACH END. FIRESTOP AS

REQUIRED.

8. PROVIDE WALL MOUNTED FIBER OPTIC INTERCONNECT

CABINET (WIC). PROVIDE ADAPTER PANELS, SPLICE TRAYS,

AND ACCESSORIES AS REQUIRED TO TO TERMINATE UP TO

36 STRANDS OF 50 MICRON, OM3, FIBER OPTIC CABLE.

TERMINATE 6 STRANDS OF OSP LOOSE TUBE FIBER FROM

CAMERA POLE NUMBER 1 AND 12 STRANDS TIGHT

BUFFERED OM3, BACKBONE CABLE FROM COLLECTION

POINT C161.

9. NOT USED.

10. PROVIDE 4" CONDUIT BELOW GRADE AS INDICATED.

11. TURN CONDUIT UP ALONG WALL TO A HEIGHT OF

APPROXIMATELY 36" AND PROVIDE BUSHINGS.

12. PROVIDE 2-1/2" CONDUIT BELOW GRADE AS INDICATED.

13. PROVIDE CAT 5E PUNCH BLOCK AND ROUTE 25 PAIR CAT 5E

CABLE TO MAIN CROSS CONNECT LOCATED IN "ELECTRICAL

161" (COLLECTION POINT C161) LOCATED AS INDICATED IN

DETAIL 1 ON SHEET T-104.

14. ROUTE ONE 4-PAIR, CAT6 CABLE IN 1" CONDUIT BELOW

GRADE TO ELEVATOR EQUIPMENT ROOM LOCATED IN

BASEMENT AS INDICATED ON SHEET T-106

15. PROVIDE 25 PAIR, CAT 5E, PUNCH BLOCK AND PROVIDE

COPPER TRUNK TO MAIN CROSS CONNECT BY ROUTING

25-PR CAT 5E CABLE TO ROOM "ELECTRICAL 161" LOCATED

AS INDICATED IN DETAIL 1 ON SHEET T-104.

16. EQUIPMENT BACKBOARD. PROVIDE TWO (2) 3/4" X 4' X 8'

SHEETS OF FIRE RESISTANT PLYWOOD PAINTED TO MATCH

ADJACENT SURFACES.

17. PROVIDE NETWORK CONNECTED, 4-DOOR ACCESS

CONTROL MODULE AND MAKE CONNECTIONS AS REQUIRED

FOR A COMPLETE FUNCTIONAL SYSTEM. SEE

SPECIFICATION SECTION 28 13 00 AND ACCESS CONTROL

DETAILS ON SHEET _____ FOR ADDITIONAL INFORMATION.

CONTROLLER SHALL BE FROM SAME MANUFACTURER AND

FAMILY, AND SHALL INTER-OPERATE WITH EXISTING

ANDOVER ACCESS CONTROL SYSTEM.

18. PROVIDE NEW TELECOMMUNICATIONS GROUNDING

BUSBAR (TGB). MAKE CONNECTIONS TO THE FOLLOWING

LOCATIONS USING #4 BONDING CONDUCTOR: MTGB

LOCATED IN ROOM "ELECTRICAL 161" LOCATED AS

INDICATED BY DETAIL 1 ON SHEET T-104, NEW TGB

LOCATED IN "STORAGE 207" AS INDICATED ON SHEET T-105,

NEAREST ACCESSIBLE STRUCTURAL STEEL, AND NEW

GROUNDING ELECTRODE (GE) INDICATED BY KEYED NOTE

NUMBER 19 ON THIS SHEET.

19. PROVIDE

5

8

" X 10' COPPER CLAD GROUNDING ELECTRODE

DRIVEN 24" BELOW GRADE. MAKE CONNECTIONS USING

EXOTHERMIC WELDS.

20. PROVIDE ACCESSORIES AND MAKE CONNECTIONS AS

REQUIRED TO CONNECT DOOR TO ACCESS CONTROL

SYSTEM. PROVIDE RACEWAY AND BACK BOXES AS

REQUIRED TO ROUTE POWER AND DATA BUS TO ELECTRIC

LOCKSET VIA POWER TRANSFER HINGE. PROVIDE DOOR

POSITION SENSOR AS REQUIRED.

21. PROVIDE 4" BACK BOX (BB4) WITH A DOUBLE GANG MUD

RING LOCATED 48" AFF. PROVIDE 1-1/2" CONDUIT TO

CONNECT WITH BACK BOX FOR FUTURE PROJECTOR (BB4

+6MB) LOCATED WITHIN SAME ROOM, AND AS INDICATED BY

KEYED NOTE NUMBER 22. COORDINATED ACTUAL

LOCATION WITH ARCHITECT AND OWNER TO DE-CONFLICT

WIT MARKER BOARD AND TACK BOARD. BACK BOX SHALL

BE RE-LOCATED WITHIN 15' AT NO ADDITIONAL COST TO

OWNER.

22. PROVIDE 4" BACK BOX (BB4) WITH A DOUBLE GANG MUD

RING LOCATED 90" AFF. LOCATION SHALL BE

APPROXIMATELY 6" ABOVE, AND 4"OFF-CENTER OF MARKER

BOARD. EXACT LOCATION SHALL BE COORDINATED WITH

ARCHITECT AND OWNER TO FACILITATE PROJECTOR

INSTALLATION. PROVIDE 1-1/2" CONDUIT TO CONNECT WITH

BACK BOX FOR FUTURE PC CONNECTION (BB4 +48)

LOCATED WITHIN SAME ROOM, AND AS INDICATED BY

KEYED NOTE NUMBER 21.

23. PROVIDE APPROXIMATELY 14"X14" HANDHOLE.

COORDINATE EXACT LOCATION WITH SITE CONDITIONS

AND OWNER.

24. ROUTE #4 TELECOMMUNICATION BONDING CONDUCTOR IN

1" CONDUIT BELOW GRADE. CONDUCTOR ROUTES TO DATA

COLLECTION POINT H210 LOCATED IN STAORAGE 207 (SEE

RELATED KEYED NOTE NUMBER 18) VIA "JANITOR 103" AND

STORAGE 207".

25. DATA JACK AND WIRELESS ACCESS POINT TO BE PROVIDE

UNDER RENOVATION PHASE CONTRACT AND IS NOT

INCLUDED IN THIS CONTRACT (NIC).

26. PROVIDE APPROXIMATELY 24"X36" HANDHOLE.

COORDINATE EXACT LOCATION WITH SITE CONDITIONS

AND OWNER.

27. ROUTE 1-1/2" CONDUIT UP TO LOCATION ABOVE

ACCESSIBLE CEILING AND, TURN HORIZONTAL, AND STUB

CONDUIT INTO INTERSTITIAL SPACE AT AN ACCESSIBLE

LOCATION.

#

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-103SCALE:

NORTH

1/8" = 1'-0"

AREA 'C' FIRST FLOOR SYSTEMS PLAN

105

CORRIDOR

10

2

111

113

112

107

104

103

101

106

109

110

108

114

CP-E124

MA

TC

HLIN

E

Area A Area B

Area DArea C

EXG.

KEYPLAN

KEYED NOTES:

1. PROVIDE FLUSH MOUNTED, WEATHERPROOF, BACK BOX FOR NEW EXTERIOR SURVEILLANCE

CAMERA. SEE ADJACENT ELEVATION ANNOTATION. COORDINATE EXACT HEIGHT AND

LOCATION WITH OWNER AND LOCATION CONDITIONS. BACK BOX SHALL INCLUDE A 3/4"

CONDUIT ROUTED TO AN NEARBY INTERIOR ACCESSIBLE LOCATION. BACK BOX SHALL INCLUDE

A WEATHERPROOF COVER PLATE WITH THREADED CONNECTION(S) FOR MINIMUM TWO FUTURE

LFNC (SEALTIGHT) CONNECTIONS.

2. PROVIDE CAT 6, 8P8C MODULAR (ETHERNET) JACK(S) AS INDICATED IN A SURFACE MOUNT

STYLE BOX ABOVE CEILING IN AN ACCESSIBLE, BUT CONCEALED, WHERE POSSIBLE, LOCATION

FOR NEW NETWORK CONNECTED SURVEILLANCE CAMERA(S). CONTRACTOR SHALL LEAVE 10'

SERVICE LOOP(S) NEATLY COILED, SECURED IN ACCESSIBLE LOCATION NEAR CONNECTOR.

3. PROVIDE CAT6, 8P8C MODULAR (ETHERNET) JACK(S) AS INDICATED IN A SURFACE MOUNT

STYLE BOX ABOVE CEILING IN AN ACCESSIBLE, BUT CONCEALED, WHERE POSSIBLE, LOCATION

FOR NEW AND FUTURE NETWORK CONNECTED WIRELESS ACCESS POINT(S). CONTRACTOR

SHALL LEAVE 15' SERVICE LOOP(S) NEATLY COILED, SECURED IN ACCESSIBLE LOCATION NEAR

CONNECTOR.

4. PROVIDE ACCESSORIES AND MAKE CONNECTIONS AS REQUIRED TO CONNECT DOOR TO

ACCESS CONTROL SYSTEM. PROVIDE RACEWAY AND BACK BOXES AS REQUIRED TO ROUTE

POWER AND DATA BUS TO ELECTRIC LOCKSET VIA POWER TRANSFER HINGE. PROVIDE DOOR

POSITION SENSOR AS REQUIRED.

5. EXTEND EXISTING CATV TRUNK AS INDICATED.

6. PROVIDE 4" BACK BOX (BB4) WITH A DOUBLE GANG MUD RING LOCATED 48" AFF. PROVIDE 1-1/2"

CONDUIT TO CONNECT WITH BACK BOX FOR FUTURE PROJECTOR (BB4 +6MB) LOCATED WITHIN

SAME ROOM, AND AS INDICATED BY KEYED NOTE NUMBER 7. COORDINATED ACTUAL LOCATION

WITH ARCHITECT AND OWNER TO DE-CONFLICT WIT MARKER BOARD AND TACK BOARD. BACK

BOX SHALL BE RE-LOCATED WITHIN 15' AT NO ADDITIONAL COST TO OWNER.

7. PROVIDE 4" BACK BOX (BB4) WITH A DOUBLE GANG MUD RING LOCATED 90" AFF. LOCATION

SHALL BE APPROXIMATELY 6" ABOVE, AND 4"OFF-CENTER OF MARKER BOARD. EXACT

LOCATION SHALL BE COORDINATED WITH ARCHITECT AND OWNER TO FACILITATE PROJECTOR

INSTALLATION. PROVIDE 1-1/2" CONDUIT TO CONNECT WITH BACK BOX FOR FUTURE PC

CONNECTION (BB4 +48) LOCATED WITHIN SAME ROOM, AND AS INDICATED BY KEYED NOTE

NUMBER 6.

#

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-102

SCALE:

NORTH

1/8" = 1'-0"

AREA 'B' FIRST FLOOR SYSTEMS PLAN

6 Sim

+5

4 (T

EL

)

+54 (TEL)

+54 (TEL)

+4

8

+4

8

+4

8

+4

8+

48

+4

8

+4

8

+4

8

CP-H105

+5

4 (T

EL

)

+86 CAM

+86 CAM

+54 (TEL)

+54 (TEL)

+5

4 (T

EL

)

+48

APPROX 11' AFG

APPROX

10' AFG

7

7

11

18

15

16

17

5

5

4

8

11

2

2

3

4

5

4

2

3

6

2

23

5

2

1

26

4

5

10

X

20

19

12

14

24

25

6

3

1

27

21

22

27

27

21

22

22

21

21

22

21

22

22

21

Area A Area B

Area DArea C

EXG.

KEYPLAN

KEYED NOTES :

1. PROVIDE FLUSH MOUNTED, WEATHERPROOF, BACK BOX

FOR NEW EXTERIOR SURVEILLANCE CAMERA. SEE

ADJACENT ELEVATION ANNOTATION. COORDINATE EXACT

HEIGHT AND LOCATION WITH OWNER AND LOCATION

CONDITIONS. BACK BOX SHALL INCLUDE A 3/4" CONDUIT

ROUTED TO AN NEARBY INTERIOR ACCESSIBLE LOCATION.

BACK BOX SHALL INCLUDE A WEATHERPROOF COVER

PLATE WITH THREADED CONNECTION(S) FOR MINIMUM TWO

FUTURE LFNC (SEALTIGHT) CONNECTIONS.

2. PROVIDE CAT 6, 8P8C MODULAR (ETHERNET) JACK(S) AS

INDICATED IN A SURFACE MOUNT STYLE BOX ABOVE

CEILING IN AN ACCESSIBLE, BUT CONCEALED, WHERE

POSSIBLE, LOCATION FOR NEW AND FUTURE NETWORK

CONNECTED SURVEILLANCE CAMERA(S). CONTRACTOR

SHALL LEAVE 10' SERVICE LOOP(S) NEATLY COILED,

SECURED IN ACCESSIBLE LOCATION NEAR CONNECTOR.

3. PROVIDE CAT6, 8P8C MODULAR (ETHERNET) JACK(S) AS

INDICATED IN A SURFACE MOUNT STYLE BOX ABOVE

CEILING IN AN ACCESSIBLE, BUT CONCEALED, WHERE

POSSIBLE, LOCATION FOR NEW AND FUTURE NETWORK

CONNECTED WIRELESS ACCESS POINT(S). CONTRACTOR

SHALL LEAVE 15' SERVICE LOOP(S) NEATLY COILED,

SECURED IN ACCESSIBLE LOCATION NEAR CONNECTOR

4. PROVIDE 24" X 48" CEILING MOUNTED ACTIVE NETWORKING

EQUIPMENT ENCLOSURE AS SPECIFIED. ENCLOSURE

SHALL ACT AS THE DATA COLLECTION POINT FOR ROOM(S)

AS INDICATED BY THE HOMERUN ANNOTATION ADJACENT

EACH WORK AREA OUTLET. ENCLOSURE SHALL CONTAIN

AND INCLUDE PATCH PANELS, WIRE MANAGEMENT

ACCESSORIES, COPPER AND FIBER TERMINATION ADAPTER

PLATES AS REQUIRED TO TERMINATE STRUCTURED WIRING

SYSTEM. ACTIVE NETWORKING EQUIPMENT SHALL BE

PROVIDED AS SPECIFIED. PROVIDE 120 VOLT BRANCH

CIRCUIT CONNECTION AS REQUIRED. SEE ELECTRICAL

SHEETS FOR ADDITIONAL INFORMATION. UNIT SHALL BE

SUPPORTED FROM STRUCTURAL BUILDING COMPONENTS

IN ACCORDANCE WITH MANUFACTURER

RECOMMENDATIONS AND IN ACCORDANCE WITH

INTERNATIONAL BUILDING CODE.

5. PROVIDE FIBER OPTIC BACKBONE CABLING AS INDICATED

AND SPECIFIED. CABLES SHALL BE ROUTED TO

COLLECTION POINT C161 LOCATED AS SHOWN IN DETAIL 1

ON SHEET T-104. SEE FIBER ONE-LINE FOR ADDITIONAL

INFORMATION.

6. PROVIDE 3" EMT CONDUIT ABOVE HARD CEILING AS

INDICATED.

7. PROVIDE 4" EMT CONDUIT ROUTED ABOVE CEILING AND

WITHIN SOFFIT SPACE AS INDICATED. PROVIDE PROVIDE

PULL ROPE AND BUSHINGS ON EACH END. FIRESTOP AS

REQUIRED.

8. PROVIDE WALL MOUNTED FIBER OPTIC INTERCONNECT

CABINET (WIC). PROVIDE ADAPTER PANELS, SPLICE TRAYS,

AND ACCESSORIES AS REQUIRED TO TO TERMINATE UP TO

36 STRANDS OF 50 MICRON, OM3, FIBER OPTIC CABLE.

TERMINATE 6 STRANDS OF OSP LOOSE TUBE FIBER FROM

CAMERA POLE NUMBER 1 AND 12 STRANDS TIGHT

BUFFERED OM3, BACKBONE CABLE FROM COLLECTION

POINT C161.

9. NOT USED.

10. PROVIDE 4" CONDUIT BELOW GRADE AS INDICATED.

11. TURN CONDUIT UP ALONG WALL TO A HEIGHT OF

APPROXIMATELY 36" AND PROVIDE BUSHINGS.

12. PROVIDE 2-1/2" CONDUIT BELOW GRADE AS INDICATED.

13. PROVIDE CAT 5E PUNCH BLOCK AND ROUTE 25 PAIR CAT 5E

CABLE TO MAIN CROSS CONNECT LOCATED IN "ELECTRICAL

161" (COLLECTION POINT C161) LOCATED AS INDICATED IN

DETAIL 1 ON SHEET T-104.

14. ROUTE ONE 4-PAIR, CAT6 CABLE IN 1" CONDUIT BELOW

GRADE TO ELEVATOR EQUIPMENT ROOM LOCATED IN

BASEMENT AS INDICATED ON SHEET T-106

15. PROVIDE 25 PAIR, CAT 5E, PUNCH BLOCK AND PROVIDE

COPPER TRUNK TO MAIN CROSS CONNECT BY ROUTING

25-PR CAT 5E CABLE TO ROOM "ELECTRICAL 161" LOCATED

AS INDICATED IN DETAIL 1 ON SHEET T-104.

16. EQUIPMENT BACKBOARD. PROVIDE TWO (2) 3/4" X 4' X 8'

SHEETS OF FIRE RESISTANT PLYWOOD PAINTED TO MATCH

ADJACENT SURFACES.

17. PROVIDE NETWORK CONNECTED, 4-DOOR ACCESS

CONTROL MODULE AND MAKE CONNECTIONS AS REQUIRED

FOR A COMPLETE FUNCTIONAL SYSTEM. SEE

SPECIFICATION SECTION 28 13 00 AND ACCESS CONTROL

DETAILS ON SHEET _____ FOR ADDITIONAL INFORMATION.

CONTROLLER SHALL BE FROM SAME MANUFACTURER AND

FAMILY, AND SHALL INTER-OPERATE WITH EXISTING

ANDOVER ACCESS CONTROL SYSTEM.

18. PROVIDE NEW TELECOMMUNICATIONS GROUNDING

BUSBAR (TGB). MAKE CONNECTIONS TO THE FOLLOWING

LOCATIONS USING #4 BONDING CONDUCTOR: MTGB

LOCATED IN ROOM "ELECTRICAL 161" LOCATED AS

INDICATED BY DETAIL 1 ON SHEET T-104, NEW TGB

LOCATED IN "STORAGE 207" AS INDICATED ON SHEET T-105,

NEAREST ACCESSIBLE STRUCTURAL STEEL, AND NEW

GROUNDING ELECTRODE (GE) INDICATED BY KEYED NOTE

NUMBER 19 ON THIS SHEET.

19. PROVIDE

5

8

" X 10' COPPER CLAD GROUNDING ELECTRODE

DRIVEN 24" BELOW GRADE. MAKE CONNECTIONS USING

EXOTHERMIC WELDS.

20. PROVIDE ACCESSORIES AND MAKE CONNECTIONS AS

REQUIRED TO CONNECT DOOR TO ACCESS CONTROL

SYSTEM. PROVIDE RACEWAY AND BACK BOXES AS

REQUIRED TO ROUTE POWER AND DATA BUS TO ELECTRIC

LOCKSET VIA POWER TRANSFER HINGE. PROVIDE DOOR

POSITION SENSOR AS REQUIRED.

21. PROVIDE 4" BACK BOX (BB4) WITH A DOUBLE GANG MUD

RING LOCATED 48" AFF. PROVIDE 1-1/2" CONDUIT TO

CONNECT WITH BACK BOX FOR FUTURE PROJECTOR (BB4

+6MB) LOCATED WITHIN SAME ROOM, AND AS INDICATED BY

KEYED NOTE NUMBER 22. COORDINATED ACTUAL

LOCATION WITH ARCHITECT AND OWNER TO DE-CONFLICT

WIT MARKER BOARD AND TACK BOARD. BACK BOX SHALL

BE RE-LOCATED WITHIN 15' AT NO ADDITIONAL COST TO

OWNER.

22. PROVIDE 4" BACK BOX (BB4) WITH A DOUBLE GANG MUD

RING LOCATED 90" AFF. LOCATION SHALL BE

APPROXIMATELY 6" ABOVE, AND 4"OFF-CENTER OF MARKER

BOARD. EXACT LOCATION SHALL BE COORDINATED WITH

ARCHITECT AND OWNER TO FACILITATE PROJECTOR

INSTALLATION. PROVIDE 1-1/2" CONDUIT TO CONNECT WITH

BACK BOX FOR FUTURE PC CONNECTION (BB4 +48)

LOCATED WITHIN SAME ROOM, AND AS INDICATED BY

KEYED NOTE NUMBER 21.

23. PROVIDE APPROXIMATELY 14"X14" HANDHOLE.

COORDINATE EXACT LOCATION WITH SITE CONDITIONS

AND OWNER.

24. ROUTE #4 TELECOMMUNICATION BONDING CONDUCTOR IN

1" CONDUIT BELOW GRADE. CONDUCTOR ROUTES TO DATA

COLLECTION POINT H210 LOCATED IN STAORAGE 207 (SEE

RELATED KEYED NOTE NUMBER 18) VIA "JANITOR 103" AND

STORAGE 207".

25. DATA JACK AND WIRELESS ACCESS POINT TO BE PROVIDE

UNDER RENOVATION PHASE CONTRACT AND IS NOT

INCLUDED IN THIS CONTRACT (NIC).

26. PROVIDE APPROXIMATELY 24"X36" HANDHOLE.

COORDINATE EXACT LOCATION WITH SITE CONDITIONS

AND OWNER.

27. ROUTE 1-1/2" CONDUIT UP TO LOCATION ABOVE

ACCESSIBLE CEILING AND, TURN HORIZONTAL, AND STUB

CONDUIT INTO INTERSTITIAL SPACE AT AN ACCESSIBLE

LOCATION.

#

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-103SCALE:

NORTH

1/8" = 1'-0"

AREA 'C' FIRST FLOOR SYSTEMS PLAN

DN

DN

MA

TC

HL

IN

E

CP-C161

Area A Area B

Area DArea C

EXG.

KEYPLAN

+54 (TEL)

CP-E124

CP-J132

CP

-J1

04

MA

TC

HL

IN

E

KEYED NOTES :

1. PROVIDE FLUSH MOUNTED, WEATHERPROOF, BACK BOX

FOR NEW EXTERIOR SURVEILLANCE CAMERA. SEE

ADJACENT ELEVATION ANNOTATION. COORDINATE EXACT

HEIGHT AND LOCATION WITH OWNER AND LOCATION

CONDITIONS. BACK BOX SHALL INCLUDE A 3/4" CONDUIT

ROUTED TO AN NEARBY INTERIOR ACCESSIBLE LOCATION.

BACK BOX SHALL INCLUDE A WEATHERPROOF COVER

PLATE WITH THREADED CONNECTION(S) FOR MINIMUM TWO

FUTURE LFNC (SEALTIGHT) CONNECTIONS.

2. PROVIDE CAT 6, 8P8C MODULAR (ETHERNET) JACK(S) AS

INDICATED IN A SURFACE MOUNT STYLE BOX ABOVE

CEILING IN AN ACCESSIBLE, BUT CONCEALED, WHERE

POSSIBLE, LOCATION FOR NEW AND FUTURE NETWORK

CONNECTED SURVEILLANCE CAMERA(S). CONTRACTOR

SHALL LEAVE 10' SERVICE LOOP(S) NEATLY COILED,

SECURED IN ACCESSIBLE LOCATION NEAR CONNECTOR.

3. PROVIDE CAT6, 8P8C MODULAR (ETHERNET) JACK(S) AS

INDICATED IN A SURFACE MOUNT STYLE BOX ABOVE

CEILING IN AN ACCESSIBLE, BUT CONCEALED, WHERE

POSSIBLE, LOCATION FOR NEW AND FUTURE NETWORK

CONNECTED WIRELESS ACCESS POINT(S). CONTRACTOR

SHALL LEAVE 15' SERVICE LOOP(S) NEATLY COILED,

SECURED IN ACCESSIBLE LOCATION NEAR CONNECTOR

4. PROVIDE 24" X 48" CEILING MOUNTED ACTIVE NETWORKING

EQUIPMENT ENCLOSURE AS SPECIFIED. ENCLOSURE

SHALL ACT AS THE DATA COLLECTION POINT FOR ROOM(S)

AS INDICATED BY THE HOMERUN ANNOTATION ADJACENT

EACH WORK AREA OUTLET. ENCLOSURE SHALL CONTAIN

AND INCLUDE PATCH PANELS, WIRE MANAGEMENT

ACCESSORIES, COPPER AND FIBER TERMINATION ADAPTER

PLATES AS REQUIRED TO TERMINATE STRUCTURED WIRING

SYSTEM. ACTIVE NETWORKING EQUIPMENT SHALL BE

PROVIDED AS SPECIFIED. PROVIDE 120 VOLT BRANCH

CIRCUIT CONNECTION AS REQUIRED. SEE ELECTRICAL

SHEETS FOR ADDITIONAL INFORMATION. UNIT SHALL BE

SUPPORTED FROM STRUCTURAL BUILDING COMPONENTS

IN ACCORDANCE WITH MANUFACTURER

RECOMMENDATIONS AND IN ACCORDANCE WITH

INTERNATIONAL BUILDING CODE.

5. PROVIDE FIBER OPTIC BACKBONE CABLING AS INDICATED

AND SPECIFIED. CABLES SHALL BE ROUTED TO

COLLECTION POINT C161 LOCATED AS SHOWN IN DETAIL 1

ON SHEET T-104. SEE FIBER ONE-LINE FOR ADDITIONAL

INFORMATION.

6. PROVIDE 4" BACK BOX (BB4) WITH A DOUBLE GANG MUD

RING LOCATED 48" AFF. PROVIDE 1-1/2" CONDUIT TO

CONNECT WITH BACK BOX FOR FUTURE PROJECTOR (BB4

+6MB) LOCATED WITHIN SAME ROOM, AND AS INDICATED BY

KEYED NOTE NUMBER 7. COORDINATED ACTUAL LOCATION

WITH ARCHITECT AND OWNER TO DE-CONFLICT WIT

MARKER BOARD AND TACK BOARD. BACK BOX SHALL BE

RE-LOCATED WITHIN 15' AT NO ADDITIONAL COST TO

OWNER.

7. PROVIDE 4" BACK BOX (BB4) WITH A DOUBLE GANG MUD

RING LOCATED 90" AFF. LOCATION SHALL BE

APPROXIMATELY 6" ABOVE, AND 4"OFF-CENTER OF MARKER

BOARD. EXACT LOCATION SHALL BE COORDINATED WITH

ARCHITECT AND OWNER TO FACILITATE PROJECTOR

INSTALLATION. PROVIDE 1-1/2" CONDUIT TO CONNECT WITH

BACK BOX FOR FUTURE PC CONNECTION (BB4 +48)

LOCATED WITHIN SAME ROOM, AND AS INDICATED BY

KEYED NOTE NUMBER 6.

8. PROVIDE APPROXIMATELY 14"X14" HANDHOLE.

COORDINATE EXACT LOCATION WITH SITE CONDITIONS

AND OWNER.

9. COORDINATE WITH ELECTRICAL TRADES TO PROVIDE DUAL

CHANNEL VERTICAL POWER/DATA POLE FOR COMPUTER

WORKSTATIONS.

10. ROUTE 1-1/2" CONDUIT UP TO LOCATION ABOVE

ACCESSIBLE CEILING AND, TURN HORIZONTAL, AND STUB

CONDUIT INTO INTERSTITIAL SPACE AT AN ACCESSIBLE

LOCATION.

11. PROVIDE ACCESSORIES AND MAKE CONNECTIONS AS

REQUIRED TO CONNECT DOOR TO ACCESS CONTROL

SYSTEM. PROVIDE RACEWAY AND BACK BOXES AS

REQUIRED TO ROUTE POWER AND DATA BUS TO ELECTRIC

LOCKSET VIA POWER TRANSFER HINGE. PROVIDE DOOR

POSITION SENSOR AS REQUIRED.

12. PROVIDE NEW TAP BLOCK AS REQUIRED. PROVIDE FOUR

TAP MINIMUM BLOCK SIZE. CONTRACTOR SHALL PROVIDE

CALCULATIONS AND DETERMINE TAP SETTINGS BASED ON

ACTUAL CIRCUITRY AND SITE CONDITIONS.

13. PROVIDE 4' BACK BOX WITH DUPLEX MUD RING AND BLANK

STAINLESS STEEL COVER PLATE FOR FUTURE VIDEO

DISPLAY EQUIPMENT. LOCATE BACK BOX ADJACENT CATV

OUTLET APPROXIMATELY CENTERED VERTICALLY WITH

FACE OF SOFFIT

14. PROVIDE 4' BACK BOX WITH DUPLEX MUD RING AND BLANK

STAINLESS STEEL COVER PLATE FOR FUTURE VIDEO

CAMERA EQUIPMENT. LOCATE BACK BOX WITHIN RANGE

HOOD AND APPROXIMATELY CENTER OF FRONT OF

COOKING RANGE.

15. PROVIDE 4' BACK BOX WITH DUPLEX MUD RING AND BLANK

STAINLESS STEEL COVER PLATE FOR FUTURE VIDEO

CAMERA EQUIPMENT. LOCATE BACK BOX WITHIN RANGE

HOOD AND APPROXIMATELY CENTERED OVER FOOD PREP

AREA.

16. PROVIDE FLUSH MOUNTED WALL ENCLOSURE WITH A

HINGED COVER APPROXIMATELY 14" w X 12" t 4" d.

ENCLOSURE SHALL BE WHITE, OR OFF WHITE, AND SHALL

INCLUDE 1" RACEWAYS TO FUTURE CAMERA AND MONITOR

LOCATION INDICATED BY KEYED NOTE NUMBERS 13, 14 AND

15. COORDINATE EXACT LOCATION WITH OWNER,

ARCHITECT AND SITE CONDITIONS.

#

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-104

SCALE:

NORTH

1/8" = 1'-0"

AREA 'D' FIRST FLOOR SYSTEMS PLAN

ELECTRICAL ROOM 161

DATA COLLECTION POINT C161

DN

DN

2

1

3

10

11

11

16

17

13

14

15

7

6

4

12

5

Area A Area B

Area DArea C

EXG.

KEYPLAN

KEYED NOTES:

1. PROVIDE 4" EMT CONDUIT FOR DATA CABLING FROM "STORAGE 210" TO

INTERSTITIAL SPACE ABOVE FIRST FLOOR CEILING ON AS INDICATED.

PROVIDE BUSHINGS ON CONDUIT.

2. PROVIDE 4" EMT CONDUIT TO "STORAGE 120" LOCATED IN "KIDDIE CITY" AS

INDICATED ON SHEET T-101. ROUTE CONDUIT VERTICALLY DOWN TO A

LEVEL BELOW ORCHESTRA PIT FLOOR BEFORE TURNING HORIZONTAL

AND RUNNING WEST. PROVIDE BUSHINGS ON EACH END.

3. PROVIDE 4" EMT CONDUIT ROUTED DOWN TO EXTERIOR HAND HOLE

INDICATED BY KEYED NOTE NUMBER 18 ON SHEET T-101. PROVIDE

PROVIDE PULL ROPE AND BUSHING.

4. EQUIPMENT BACKBOARD. PROVIDE 3/4" X 4' X 8' SHEET OF FIRE

RESISTANT PLYWOOD PAINTED TO MATCH ADJACENT SURFACES.

(APPROXIMATELY 36" WIDE X 96" TALL).

5. PROVIDE CAT 5E PUNCH BLOCK AND ROUTE 12 PAIRS OF CAT 5E CABLE

TO PUNCH BLOCK LOCATED IN "ELECTRICAL 135" AS INDICATED ON SHEET

T-103.

6. PROVIDE NEW TELECOMMUNICATIONS GROUNDING BUSBAR (TGB). MAKE

CONNECTIONS TO THE FOLLOWING LOCATIONS USING #4 BONDING

CONDUCTOR: TGB LOCATED IN ROOM "ELECTRICAL 135" LOCATED AS

INDICATED BY DETAIL 1 ON SHEET T-103, NEAREST ACCESSIBLE

STRUCTURAL STEEL, AND EQUIPMENT GROUNDING BUS ON NEAREST

ELECTRICAL PANEL.

7. PROVIDE 2-POST EQUIPMENT RACK AND ACTIVE ELECTRONIC EQUIPMENT

AS SPECIFIED. RACK SHALL BE SECURELY BOLTED TO FLOOR AND

BONDED TO TELECOMMUNICATION EQUIPMENT GROUNDING BUSBAR.

8. ROUTE CONDUIT(S) FROM DATA COLLECTION POINT F210 VERTICALLY

INTO INTERSTITIAL SPACE, TURN HORIZONTAL AND TERMINATE CONDUIT

AT AN ACCESSIBLE LOCATION. PROVIDE BUSHING ON CONDUIT END(S).

9. PROVIDE 4" CONDUIT BELOW GRADE FROM "STORAGE 120" LOCATED

WITHIN "KIDDIE CITY" AREA AND DATA COLLECTION POINT F210 LOCATED

IN "STORAGE 210" LOCATED ON SECOND FLOOR AS INDICATED ON SHEET

T-105. CONDUIT ROUTES BELOW BASEMENT ORCHESTRA PIT LEVEL AND

ROUTES VERTICALLY WITHIN CHASE AS INDICATED BY KEYED NOTE

NUMBER 17.

10. STUB 4" EMT CONDUIT FROM INTERSTITIAL SPACE ABOVE CEILING ON

FIRST FLOOR TO APPROXIMATELY 9"AFF IN "STORAGE 207" (TO HEIGHT OF

CABLE TRAY). PROVIDE BUSHINGS ON BOTH ENDS.

11. STUB TWO (2) 2-1/2" & ONE (1) 1" EMT CONDUIT FROM "JANITOR 103"

BELOW (ON FIRST FLOOR) TO APPROXIMATELY 9"AFF IN "STORAGE 207"

(TO HEIGHT OF CABLE TRAY). PROVIDE BUSHINGS ON BOTH END.

12. PROVIDE NETWORK CONNECTED, 4-DOOR ACCESS CONTROL MODULE

AND MAKE CONNECTIONS AS REQUIRED FOR A COMPLETE FUNCTIONAL

SYSTEM. SEE SPECIFICATION SECTION 28 13 00 AND ACCESS CONTROL

DETAILS ON SHEET _____ FOR ADDITIONAL INFORMATION. CONTROLLER

SHALL BE FROM SAME MANUFACTURER AND FAMILY, AND SHALL

INTER-OPERATE WITH EXISTING ANDOVER ACCESS CONTROL SYSTEM.

13. ROUTE 2' EMT CONDUIT AS HIGH AS POSSIBLE. ROUTE ALONG CEILING

JOISTS AND ABOVE ALL ACOUSTICAL PANELS, LIGHTING ETC. CONDUIT

FOR PROJECT INPUT SIGNAL.

14. HORIZONTAL 2" EMT CONDUIT STUB FROM VERTICAL RISER LEADING TO

DIRECTORS CHAIR HAND HOLE INDICATED BY KEYED NOTE NUMBER 15.

15. VERTICAL RISER DOWN TO BELOW GRADE AND OVER TO DIRECTOR'S

CHAIR HAND HOLE AS INDICATED BY KEYED NOTE NUMBER 31 ON SHEET

E-101.

16. PROVIDE 2" EMT CONDUIT STUB BETWEEN LIGHTING 206 AND STORAGE

207 FOR LIGHTING CONTROL CABLING AS REQUIRED.

17. CONDUITS UP FROM BELOW - THREE EACH,

3

4

", FROM CEILING MOUNTED

SURVEILLANCE CAMERAS (SCAM #s 25, 28 & 29) IN THEATER AND TWO

EACH, 2" CONDUITS FROM DIRECTORS CHAIR HAND HOLE.

18. ROUTE 2" EMT CONDUIT AS INDICATED. CONDUIT IS FOR LIGHTING

CONTROL CABLING AS MAY BE REQUIRED FOR ROOM "LIGHTING 203".

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-105

SCALE:

NORTH

1/8" = 1'-0"

AREA 'A' SECOND FLOOR SYSTEMS PLAN

UP

3

4

2

1

5

Area A Area B

Area DArea C

EXG.

KEYPLAN

KEYED NOTES:

1. ROUTE ONE 4-PAIR, CAT6 CABLE IN 1" CONDUIT BELOW GRADE FROM

"ELECTRICAL 135" AS INDICTED ON SHEET T-103. CONDUIT SHALL ENTER

SIDE OF EQUIPMENT ROOM. PROVIDE ANNULAR SEAL FOR A

WATERTIGHT PENETRATION.

2. MAKE CONNECTIONS TO ELEVATOR EMERGENCY TELEPHONE AS

REQUIRED FOR A COMPLETE FUNCTIONAL SYSTEM.

3. CONDUIT FROM "STORAGE 120" IN "KIDDIE CITY" AS INDICATED ON SHEET

T-101. ROUTE CONDUIT BELOW BASEMENT FLOOR APPROXIMATELY AS

INDICATED.

4. TURN CONDUIT(S) UP TO ROUTE VERTICALLY IN CHASE LOCATED IN

FIRST FLOOR. CONDUIT CONTINUE UP TO "STORAGE 210" LOCATED ON

MEZZANINE LEVEL ABOVE.

5. PROVIDE FLUSH MOUNTED WALL ENCLOSURE WITH A HINGED COVER.

ENCLOSURE SHALL BE APPROXIMATELY 12" w X 12" t X 6" d. FOR USE AS

REQUIRED BY DIRECTORS CHAIR CIRCUITRY.

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-106

SCALE:

NORTH

1/8" = 1'-0"

AREA 'A' BASEMENT SYSTEMS PLAN

+54

(TEL)

+5

4 (T

EL

)

KEYED NOTES

:

1. EXISTING 2" CONDUIT STUBBED AND CAPPED. EXTEND EXISTING CONDUIT AS INDICATED

ON SYSTEMS SITE PLAN ON SHEET T-100. ROUTE 12-STRAND, INDOOR/OUTDOOR, 50

MICRON, OM3, FIBER OPTIC CABLE IN CONDUIT BELOW GRADE. CABLE SHALL BE

ROUTED UNINTERRUPTED TO ELECTRIC 161 AS INDICATED ON ONE-LINE DIAGRAM ON

SHEET T-501. ACTIVE FIBER STRANDS SHALL BE EXTENDED FROM ELECTRICAL 161

(CP-C161) TO STORAGE C-161 (CP-C161) BY CROSS CONNECTING OR FUSION SPLICING

STRANDS AS REQUIRED.

2. PROVIDE WALL MOUNT, 19" RACK MOUNT, EQUIPMENT CABINET AS SPECIFIED. CABINET

SHALL CONTAIN FIBER TERMINATION ENCLOSURE WITH SPLICE TRAYS, STORAGE

SPOOLS AND OTHER ACCESSORIES AS REQUIRED; 24-PORT ETHERNET SWITCH AS

SPECIFIED; 12-PORT COPPER PATCH PANEL; WIRE MANAGEMENT PANEL, AND

ACCESSORIES AS REQUIRED FOR A COMPLETE FUNCTIONAL SYSTEM.

3. PROVIDE NEW WORK AREA OUTLET FOR WALL MOUNTED IP TELEPHONE AS INDICATED.

PROVIDE METAL SURFACE MOUNT, FINISH STYLE, BACK BOX AND METAL SURFACE

MOUNT RACEWAY AS REQUIRED FOR A COMPLETE FUNCTIONAL INSTALLATION.

4. PROVIDE A SURFACE MOUNT STYLE PVC WORK AREA OUTLET WITH 6P6C MODULAR

ETHERNET JACKS AS INDICATED FOR FUTURE WIRELESS ACCESS POINT OR

SURVEILLANCE CAMERA AS INDICATED. CABLING SHALL BE IN CONDUIT TERMINATED AT

APPROXIMATELY LOCATION SHOWN. PROVIDE BUSHING ON CONDUIT STUB AND LEAVE

A 15' SERVICE LOOP IN CABLING. WORK AREA OUTLET SHALL BE SECURED TO WALL OR

STRUCTURE IN A MANOR THAT ALLOWS FUTURE RE-LOCATION.

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

T-107

SCALE:

NORTH

1/8" = 1'-0"

GREENHOUSE SYSTEMS PLAN

CAMERA # 2

CAMERA # 2

T-501

SCALE:

T-501

1

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

11-30-15

Main Data Collection Point CP-212 located in area C, Storage 212

See Sheet T-503 for additional information

Classroom Addition Area A

Classroom Addition Area B Classroom Addition Area C

Classroom Addition Area D

HEC Building

Renovated Space

Stadium Building

PRIMARY DISTRIBUTION

NETWORK BACKBONE

SECONDARYDISTRIBUTION

NETWORK BACKBONE

SECONDARY

DISTRIBUTION

SWITCH

PRIMARY

DISTRIBUTION

SWITCH

West Classroom Adddition

Greenhouse Building

See Sheet T-504 for surveillance system layer two

diagram

1

2

2

2

2

2

2

3

Storage 212

Main Telecomm Room

(Electrical 161)

X

KEYED NOTES:

1. Provide new two-post equipment rack

and equipment as specified and as

required for a complet funtional system.

Rack shall be securely bolted to floor.

2. Provide new ceiling mounted networking

equipment enclosure and equipment as

specified and as required. 24" x 48"

enclosure shall be installed so that the

bottom of the cabinet is flush with

suspended ceiling. Enclosure shall

include dedicated threaded rod supports

attached to structural members and sway

bracing in accordance with seismic code

requirements.

3. Provide new wall mounted networking

equipment enclosure and equipment as

specified and as required

ORIGINAL INFORMATION ON THIS SHEET OBTAINED FROM

CLASSROOM ADDITION CONSTRUCTION DOCUMENTS

(T-501)AND TECHNOLOGY PACKAGE DOCUMENTS

AS SUCH, INFORMATION IS SUBJECT TO REVISIONS OR

CHANGES IMPLEMENTED DURING CONSTRUCTION.,

SEE AS-BUILT DRAWINGS FOR ADDITIONAL INFORMATION

--------------------------------------------------------------------------

ONLY WORK INDICATED IS REQUIRED

T-502

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

SCALE:

LAYER 2 NETWORK DIAGRAM - ACCESS AND DISTRIBUTION LAYERS

T-502

1

NONE

11-30-15

Existing Secondary Distribution Network

Switch and interface devices

Existing Surveillance

Network Ethernet switch

Provide patch cable, Make

connection and configure

routing per specifications.

SURVEILLANCE NETWORK

Physical LAN #2

Marion

High

School

CLEARWAVE

COMCAST

INTERNET

-- ICN --

ILLINOIS

CENTURY

NET

993-0974993-2081993-2737993-2893993-6308993-6575993-8196993-8197993-8682993-9780997-0488997-3195997-3666

997-7273997-8408997-8749997-8783997-8905997-8913997-8923997-8930997-8978997-9491998-2782998-9240

unknownPSTN

For additional information

see sheets:

E-253

E-552

Providfe New Main Surveillance Sytem Network Aggregation

Switch and interface modules as specified and as required to

aggregate all remote surveillance system data collection

points using fiber optic cable connections

DATA NETWORK

Physical LAN #1

Marion

High

School

New and existing

surveillance network

Ethernet switches - see

Sheet T-504

New and existing Data

network Ethernet switches -

see Sheets T-502 & T-501

Existing Secondary Distribution Network

Switch and interface devices

Provide new

(additional) Interface

modules and ports

as specified and as

required to make

connections to new

equipment .

Storage 212 located on second floor, area C,

of Phase 3 (East) Classroom Addition

Electrical 161 located on first floor of existing building near wilsom Gymnasium

as indicated in plans for Phase 3 (East) Classroom Addition - area C

ORIGINAL INFORMATION ON THIS SHEET OBTAINED FROM

CLASSROOM ADDITION CONSTRUCTION DOCUMENTS

(T-501)AND TECHNOLOGY PACKAGE DOCUMENTS

AS SUCH, INFORMATION IS SUBJECT TO REVISIONS OR

CHANGES IMPLEMENTED DURING CONSTRUCTION.,

SEE AS-BUILT DRAWINGS FOR ADDITIONAL INFORMATION

--------------------------------------------------------------------------

ONLY WORK INDICATED IS REQUIRED

Total of 15 each,

1 Gb Fiber

Ethernet links

10 Gbe copper link

Provide New Border Switch and interface

modules as specified and as required.

T-503

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

SCALE:

LAYER 2 NETWORK DIAGRAM - DISTRIBUTION AND NETWORK BORDER LAYERS

T-503

1

NONE

11-30-15

Classroom Addition Area A

Classroom Addition Area B

Classroom Addition Area C

Classroom Addition Area D

HEC Building

Renovated Space

Stadium Building

Surveillance Network Backbone

West Classroom Addition

Greenhouse Building

Electrical 135

Fiber

WIC

Pole

Mounted

Enclosure

Pole

Mounted

Enclosure

Pole

Mounted

Enclosure

East Classroom Addition

Existing Building

ORIGINAL INFORMATION ON THIS SHEET OBTAINED FROM

CLASSROOM ADDITION CONSTRUCTION DOCUMENTS

(T-501)AND TECHNOLOGY PACKAGE DOCUMENTS

AS SUCH, INFORMATION IS SUBJECT TO REVISIONS OR

CHANGES IMPLEMENTED DURING CONSTRUCTION.,

SEE AS-BUILT DRAWINGS FOR ADDITIONAL INFORMATION

---------- ONLY WORK INDICATED IS REQUIRED -------------

T-504

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

SCALE:

SURVEILLANCE SYSTEM LAYER 2 NETWORK DIAGRAM - ACCESS AND DISTRIBUTION LAYERS

T-504

1

NONE

11-30-15

UP

PH 4 WORK

PH 6 WORK

PH 4 WORK

PH 6 WORK

Area A Area B

Area DArea C

EXG.

KEYPLAN

FACILITIES IN THE EXISTING BUILDING

AND INDICATED ON THE DRAWINGS

HAVE BEEN TAKEN FROM EXISTING

BUILDING DRAWINGS AND FIELD

INSPECTIONS AT THE PROJECT, BUT

ITS COMPLETE ACCURACY IS NOT

GUARANTEED. CONTRACTOR SHALL

VERIFY AND/ OR DETERMINE EXISTING

CONDITIONS INVOLVING HIS WORK IN

THE FIELD.

DEMOLITION NOTES:

1. REMOVE AND LEGALLY DISPOSE OF ALL DATA, TELEPHONE, CATV

CAMERA AND SPEAKER CABLING WITHIN PHASE 6 AREA AS INDICATED.

2. RETURN TELEPHONES AND CAMERAS TO OWNER.

3. REMOVE AND LEGALLY DISPOSE OF SPEAKERS, DATA JACKS,

TELEPHONE JACKS AND RELATED EQUIPMENT.

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

TD-101

SCALE:

NORTH

1/8" = 1'-0"

AREA 'B' DEMOLITION PLAN

SP

SP

SP

SP

SP

SP

SP

SP

SP SP

B

BB

11' - 9"

Area A Area B

Area DArea C

EXG.

KEYPLAN

FACILITIES IN THE EXISTING BUILDING

AND INDICATED ON THE DRAWINGS

HAVE BEEN TAKEN FROM EXISTING

BUILDING DRAWINGS AND FIELD

INSPECTIONS AT THE PROJECT, BUT

ITS COMPLETE ACCURACY IS NOT

GUARANTEED. CONTRACTOR SHALL

VERIFY AND/ OR DETERMINE EXISTING

CONDITIONS INVOLVING HIS WORK IN

THE FIELD.

DEMOLITION NOTES:

1. REMOVE AND LEGALLY DISPOSE OF ALL DATA, TELEPHONE, CATV

CAMERA AND SPEAKER CABLING WITHIN PHASE 6 AREA AS INDICATED.

2. RETURN TELEPHONES AND CAMERAS TO OWNER.

3. REMOVE AND LEGALLY DISPOSE OF SPEAKERS, DATA JACKS,

TELEPHONE JACKS AND RELATED EQUIPMENT.

2015 DESIGN ARCHITECTS, INC.

ARNOLD, MO

HILLSBORO, IL

EAST ST. LOUIS, IL

SPRINGFIELD, IL

NEOSHO, MO

200 N. MARKET ST.

MARION, IL 62959

F: 618.998.0076

PH: 618.998.0075

TD-102

SCALE:

NORTH

1/8" = 1'-0"

AREA 'D' DEMOLITION PLAN