26
7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV - TEFC Medium Voltage 7.12 449 Frame TEFC 7.16 WPII, TEFC, TEAAC Standard Features 7.17 WPII Pricing and Kits 7.20 Pegasus™ MHV - WPII Pricing 7.21 Quantum™ LMV - TEFC Pricing 7.22 Pegasus™ MHV - TEAAC Pricing 7.23 Dimensions TABLE OF CONTENTS

Upload: others

Post on 18-Apr-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

7.0 High HP Low and Medium Voltage

7.1 Quantum™ LMV - TEFC Low Voltage

7.7 Quantum™ LMV - TEFC Medium Voltage

7.12 449 Frame TEFC

7.16 WPII, TEFC, TEAAC Standard Features

7.17 WPII Pricing and Kits

7.20 Pegasus™ MHV - WPII Pricing

7.21 Quantum™ LMV - TEFC Pricing

7.22 Pegasus™ MHV - TEAAC Pricing

7.23 Dimensions

TABLE OF CONTENTS

probe1
New Stamp
Page 2: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Make a Difference

Imagine a motor that saves enough energy to pay for itself in 11/2 years.

Imagine that using it for one year saves enough energy to power 2 US households.

Imagine that this same motor reduces carbon dioxide emissions by 20 tons every year.

That’s the equivalent of planting an 5 acre forest.

Statements based on: replacement of a 100 HP 1800 RPM Pre-EPAct (Energy Policy Act of 1992) motor with a 100 HP 1800 RPM X$D Ultra® motor; Average Retail Price of Electricity for Industrial customers and Average [US] Residen-tial Monthly [electricity] Use per Energy Information Administration “Basic Electricity Statistics” for 2004 - http://www.eia.doe.gov; carbon dioxide US power plant emissions output rate for 2000 per US Envronmental Protection Agency “Clean Energy” - http://www.epa.gov/cleanerenergy/egrid; Emissions Reduction as Compared to Tree Plantings per www.epa.gov/appdstar/pdf/brochure.pdf. Actual efficiency improvement and benefits may vary based upon horsepower rating of replaced and replacement motor, performance characteristics of the replaced motor, hours of motor operation per year, actual cost of electricity and other factors.

The GE monogram, X$D Ultra and GEGARD2000 are trademarks and ecomagination is a service mark of the General Electric Company. NEMA Premium is a trademark of NEMA. ©2006 General Electric All rights reserved.

NEMA Premium Extra Severe Duty Motors

a product ofSM

www.gemotors.comX$DUltra®

probe1
New Stamp
Page 3: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Qua

ntum

™ L

MV—

TEFC

7.1

Quantum™ LMV—TEFCSevere Duty Low Voltage

Standard Features

HP Range 350-600

Poles 2

Voltage 460, Usable at 400V 50 Hz 1.0 SF

Efficiency NEMA Premium (Meets or exceeds EISA efficiency requirements 350-500HP)

NEMA Design Standard Torque

Altitude 3300 ft

Ambient 40°C

Balance/Vibration 0.075 in/sec

Bearing Caps Both Ends

Bearing Protection IP55; Shaft slinger both ends

Bearing Type Single Shielded Ball

Conduit Box Cast Iron; Gasketed and rotatable in 90 degree increments

Drains Stainless Steel T-drains in lowest section of both endshields

Enclosure TEFC

End Shield Cast Iron

Fan Aluminum - Unidirectional

Fan Cover Fabricated Steel

Fasteners SAE Grade 5

Frame Material Cast Iron

Frame Size 509-5013

Frequency 60 or 50 Hz

Ground Ground in conduit box and 2 NEMA Type ground pads on frame

Insulation Class Class F

Insulation System Epoxy VPI

Inverter Capabilities Consult Factory

L10 Bearing Life Direct Coupled: 65,000 hrs

Leads Permanently numbered, Non-wicking

Lifting Means Two (2) cast in lifting lugs

Lubrication Polyurea Grease

Mounting Foot mounted F1 only, contact factory for F2 mounting options

Mounting Holes Dual drilled for 508/509, 5010/5011, 5012/5013 mounting

Nameplate 316 Stainless Steel

Paint Epoxyester Buff

Relubrication Yes, both ends; extended through the fan cover

Rotor Cast Aluminum

Service Factor 1.15

Shaft Material AISI 1045

Temperature Rise 80°C @ 1.0 SF

Tests NEMA Routine; IEEE 112 Method B

Thermal Protection 3 NC Thermostats

Time Rating Continuous

Vibration Pads Cast in vibration pads for repeatable measurements

Warranty 36 months from date of purchase or 42 months from date of shipment, whichever occurs first

probe1
New Stamp
Page 4: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

7.2

Quantum

™ LM

V—TEFC

Quantum™ LMV—TEFCSevere Duty Low Voltage

Pricing

Severe Duty Low Voltage

HP RPM Volts Frame FLA Nom. Eff. Cat. No. List PricePrice

Symbol Norm. Stk. Wt. (lbs) C Dim. (in) Notes

350 3600 460 5011LS 364/366 95.8 Q527 $24,921 G4-7U5LV N 5200 74.14 106, 145

400 3600 460 5011LS 416/418 95.8 Q528 $26,420 G4-7U5LV N 5300 74.14 106, 145

450 3600 460 5011LS 468/470 95.8 Q529 $27,644 G4-7U5LV N 5375 74.14 106, 145

500 3600 460 5011LS 517/517 95.8 Q530 $28,630 G4-7U5LV N 5750 74.14 106, 145

600 3600 460 5013ST 617/620 95.8 Q531 $35,174 G4-7U5LV N 6700 83.13 106, 145

Severe Duty Low Voltage with C-Face

HP RPM Volts Frame FLA Nom. Eff. Cat. No. List PricePrice

Symbol Norm. Stk. Wt. (lbs) C Dim. (in) Notes

350 3600 460 5011LSC 364/366 95.8 Q522 $26,529 G4-7U5LV N 5200 75.08 106, 145

400 3600 460 5011LSC 416/418 95.8 Q523 $28,028 G4-7U5LV N 5300 75.08 106, 145

450 3600 460 5011LSC 468/470 95.8 Q524 $29,252 G4-7U5LV N 5375 75.08 106, 145

500 3600 460 5011LSC 517/517 95.8 Q525 $30,238 G4-7U5LV N 5750 75.08 106, 145

600 3600 460 5013STC 617/620 95.8 Q526 $36,782 G4-7U5LV N 6700 84.08 106, 145

Notes:106 Usable on 400V, 50 Hz at 1.0 service factor145 CCW rotation facing opposite drive end. For CW fans use Part #148C8070AA1; except for 350 HP 3600 RPM motors use #148C8070BA1

probe1
New Stamp
Page 5: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Qua

ntum

™ L

MV—

TEFC

7.3

Quantum™ LMV—TEFCSevere Duty Low Voltage

Typical Performance Data

Volts: 460 Frequency: 60 Hz HP: 350-600

HPFL

RPMNP FLA

Design LRA

Code KVA/HP

FLT (lb-ft)

LRT (lb-ft)

BDT (lb-ft)

NP Eff. Full

Load

75% Load Eff.

50% Load Eff.

NP PF Full

Load

75% Load

Power Factor

50% Load

Power Factor

Max KVAR

350 3565 364.0 2306.0 G 515.6 526.9 1330.2 95.8 95.6 94.9 94.0 93.6 91.4 42.1

400 3565 416.0 2631.4 G 589.2 595.1 1507.8 95.8 95.6 94.9 94.0 93.4 91.0 49.8

450 3565 468.0 2969.2 G 663.0 700.8 1698.6 95.8 95.8 95.2 94.0 93.8 91.6 53.1

500 3560 517.0 3310.2 G 737.0 824.0 1878.6 95.8 96.0 95.5 94.5 94.2 92.3 54.7

600 3570 617.0 3791.8 G 882.4 734.2 2153.9 95.8 96.4 96.1 95.0 94.8 93.4 56.8

Note: Performance data is the same for standard and C-Face motors.

probe1
New Stamp
Page 6: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

7.4

Quantum

™ LM

V—TEFC

Quantum™ LMV—TEFCSevere Duty Low Voltage with IEEE 841 Features

Standard Features

HP Range 300-500

Poles 2,4,6

Voltage 460

Efficiency NEMA Premium (Meets or exceeds IEEE 841-2009 efficiency requirements)

NEMA Design Standard Torque

Altitude 3300 ft

Ambient 40°C to -25°C

Balance/Vibration 0.075 in/sec

Bearing Caps Both Ends

Bearing Protection IP55; Inpro Seal on both ends

Bearing Type Single Shielded Ball

Conduit Box Cast Iron; Gasketed and rotatable in 90 degree increments

Div 2 Temp Codes Motors have an Auto Ignition Temperature of 200 or 215 degree C stamped on the nameplate. (See notes)

Drains Stainless Steel T-drains in lowest section of both endshields

Enclosure TEFC

End Shield Cast Iron

Fan Aluminum (Unidirectional on 2 poles)

Fan Cover Fabricated Steel

Fasteners SAE Grade 5

Foot Draft Angle +/- 1.5 degrees

Foot Flatness 0.005 in

Frame Material Cast Iron

Frame Size 509-5013

Frequency 60 Hz

Ground Ground in conduit box and 2 NEMA Type ground pads on frame

Insulation Class Class F

Insulation System Epoxy VPI

Inverter Capabilities Consult Factory

L10 Bearing Life Direct Coupled: 130,000 hrs 4&6 pole; 65,000 hrs 2 pole

Leads Permanently numbered, Non-wicking

Lifting Means Two (2) cast in lifting lugs

Lubrication Polyurea Grease

Mounting Foot mounted F1 only, contact factory for F2 mounting options

Mounting Holes Dual drilled for 508/509, 5010/5011, 5012/5013 mounting

Nameplate 316 Stainless Steel

Oil Mist Lube Includes provisions for conversion to Oil Mist Lubrication

Paint Epoxyester Buff

Relubrication Yes, both ends; extended through the fan cover

Rotor Cast Aluminum

Service Factor 1.15

Shaft Material AISI 1045

Shaft TIR Meets IEEE 841, 0.0015 in

Special Painting Meets IEEE 841

Temperature Rise 80°C @ 1.0 SF

Tests NEMA Routine Report including vibration supplied with motor, IEEE 112 Method B

Time Rating Continuous

Vibration Pads Cast in vibration pads for repeatable measurements

Warranty 60 months from date of purchase or 66 months from date of shipment, whichever occurs first

probe1
New Stamp
Page 7: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Qua

ntum

™ L

MV—

TEFC

7.5

Quantum™ LMV—TEFCSevere Duty Low Voltage with IEEE 841 Features

Pricing

HP RPM Volts Frame FLA Nom. Eff. Cat. No. List PricePrice

Symbol Norm. Stk. Wt. (lbs) C Dim. (in) Notes

300 1200 460 509LL 339 95.8 Q808 $25,810 G4-7U5XLV Y 4650 67.13 146

350 3600 460 5011LS 364 95.8 Q800 $25,154 G4-7U5XLV Y 5400 74.14 112, 145, 146

350 1800 460 5011LL 378 96.2 Q804 $26,112 G4-7U5XLV Y 5600 75.14 146

350 1200 460 5011LL 391 95.8 Q809 $29,425 G4-7U5XLV N 5150 75.14 146

400 3600 460 5011LS 416 95.8 Q801 $26,699 G4-7U5XLV Y 5400 74.14 112, 145, 146

400 1800 460 5011LL 432 96.2 Q805 $26,225 G4-7U5XLV Y 5700 75.14 146

400 1200 460 5011LL 452 95.8 Q810 $30,710 G4-7U5XLV Y 5400 75.14 146

450 3600 460 5011LS 468 95.8 Q802 $28,022 G4-7U5XLV Y 5475 74.14 112, 145, 146

450 1800 460 5013S 484 96.2 Q806 $32,506 G4-7U5XLV N 6275 85.13 146, 147

450 1200 460 5011LL 508 95.8 Q811 $33,053 G4-7U5XLV N 5700 75.14 146

500 3600 460 5011LS 517 95.8 Q803 $29,278 G4-7U5XLV Y 5750 74.14 112, 145, 146, 147

500 1800 460 5013S 538 96.2 Q807 $33,804 G4-7U5XLV N 6750 85.13 146, 147

Notes:112 Noise level exceeds IEEE 841145 CCW rotation facing opposite drive end. For CW fans use Part #148C8070AA1; except for 350 HP 3600 RPM motors use #148C8070BA1146 Aluminum fan. Aluminum fan complies with API541147 Motors have an Auto Ignition Temperature of 215 degree C stamped on the nameplate

probe1
New Stamp
Page 8: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

7.6

Quantum

™ LM

V—TEFC

Quantum™ LMV—TEFCSevere Duty Low Voltage with IEEE 841 Features

Typical Performance Data

Volts: 460 HP: 300-500

HPFL

RPMNP FLA

Design LRA

Code KVA/HP

FLT (lb-ft)

LRT (lb-ft)

BDT (lb-ft)

NP Eff. Full

Load

75% Load Eff.

50% Load Eff.

NP PF Full

Load

75% Load

Power Factor

50% Load

Power Factor

Max KVAR

300 1185 339.0 2012.0 G 1327.2 1558.1 3497.2 95.8 96.0 95.8 86.5 84.1 77.2 73.5

350 3560 364.0 2231.7 G 515.8 516.8 1290.0 95.8 95.6 94.9 94.0 93.9 91.9 39.8

350 1785 378.0 2270.9 G 1029.1 1088.8 2550.1 96.2 96.5 96.4 90.0 88.7 84.0 64.2

350 1185 391.0 2388.1 G 1549.4 1986.3 4112.1 95.8 96.1 96.1 87.5 85.6 79.3 78.7

400 3565 416.0 2631.4 G 589.2 595.1 1507.8 95.8 95.6 94.9 94.0 93.4 91.0 49.8

400 1785 432.0 2609.6 G 1176.1 1234.9 2955.5 96.2 96.5 96.5 90.0 88.4 83.4 75.5

400 1190 452.0 2694.3 G 1765.1 2058.1 4453.3 95.8 96.4 96.3 86.5 84.5 77.9 94.3

450 3565 468.0 2969.2 G 663.0 700.8 1698.6 95.8 95.8 95.2 94.0 93.8 91.6 53.1

450 1785 484.0 2962.2 G 1323.3 1472.8 3312.2 96.2 96.3 96.2 90.5 89.1 84.5 80.5

450 1190 508.0 3178.9 G 1984.4 2399.1 5280.5 95.8 96.6 96.5 86.5 83.7 76.4 112.9

500 3560 517.0 3310.2 G 737.0 824.0 1878.6 95.8 96.0 95.5 94.5 94.2 92.3 54.7

500 1785 538.0 3304.9 G 1470.4 1676.3 3676.0 96.2 96.5 96.3 90.5 89.3 84.9 87.2

probe1
New Stamp
Page 9: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Qua

ntum

™ L

MV—

TEFC

7.7

Quantum™ LMV—TEFCSevere Duty Medium Voltage

Standard Features

HP Range 200-600

Poles 2,4,6

Voltage 2300/4000

Efficiency NEMA Premium

NEMA Design Standard Torque

Altitude 3300 ft

Ambient 40°C

Balance/Vibration 0.075 in/sec Ball Bearing; Roller Bearing 6 Pole 0.0010 in (P-P)

Bearing Caps Both Ends

Bearing Protection Shaft Slinger Both Ends

Bearing Temp Device 100 Ohm Platinum RTD both bearings

Bearing Type Single Shielded Ball; 509L & 5011L have DE Roller Bearing

Conduit Box Cast Iron

Drain Stainless Steel T-drains in lowest section of both endshields

Enclosure TEFC

End Shield Cast Iron

Fan Aluminum (Unidirectional on 2 poles)

Fan Cover Fabricated Steel

Fasteners SAE Grade 5

Frame Material Cast Iron

Frame Size 509-5013

Frequency 60 Hz

Ground Ground in conduit box and 2 NEMA Type ground pads on frame

Insulation Class Class F

Insulation System Epoxy VPI

Inverter Capabilities Consult Factory

L10 Bearing Life Direct Coupled: 130,000 hrs 4&6 pole; 65,000 hrs 2 pole; Belted 26,280 hrs

Leads Permanently numbered, Non-wicking

Lifting Means Two (2) cast in lifting lugs

Lubrication Polyurea Grease

Mounting Foot mounted F1 only, contact factory for F2 mounting options

Mounting Holes Dual drilled for 508/509, 5010/5011, 5012/5013 mounting

Nameplate 316 Stainless Steel

Paint Epoxyester Buff

Relubrication Yes, both ends; extended through the fan cover

Rotor Cast Aluminum

Service Factor 1.15, except 600HP 6 pole 1.0 SF only

Shaft Material AISI 1045; 509L & 5011L AISI 4140

Space Heater 115 volt standard space heaters, leads to main conduit box

Stator Temp Device 100 Ohm Platinum Stator RTD’s, leads to accessory box

Temperature Rise 80°C @ 1.0 SF, 600HP 6 pole Class F rise @ 1.0 SF

Tests NEMA Routine; IEEE 112 Method B

Time Rating Continuous

Vibration Pads Cast in vibration pads for repeatable measurements

Warranty 36 months from date of purchase or 42 months from date of shipment, whichever occurs first

probe1
New Stamp
Page 10: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

7.8

Quantum

™ LM

V—TEFC

Quantum™ LMV—TEFCSevere Duty Medium Voltage

Pricing

HP RPM Volts Frame FLA Nom. Eff. Cat. No. List PricePrice

Symbol Norm. Stk. Wt. (lbs) C Dim. (in) Notes

200 1200 2300/4000 509L 46.6/26.8 95.0 Q514 $36,028 G4-7U5MV Y 4450 72.38 148

250 3600 2300/4000 509LS 53.2/30.6 95.0 Q500 $35,227 G4-7U5MV Y 4650 66.13 145

250 1800 2300/4000 509LL 55.3/31.8 95.0 Q507 $33,434 G4-7U5MV Y 4350 67.13

250 1200 2300/4000 509L 57.9/33.3 95.0 Q515 $37,455 G4-7U5MV Y 4475 72.38 148

300 3600 2300/4000 509LS 63.5/36.5 95.0 Q501 $36,844 G4-7U5MV Y 4500 66.13 145

300 1800 2300/4000 509LL 66.1/38 95.0 Q508 $34,833 G4-7U5MV Y 4550 67.13

300 1200 2300/4000 5011L 68.5/39.4 95.4 Q516 $39,606 G4-7U5MV Y 5400 80.39 148

350 3600 2300/4000 5011LS 73.7/42.4 95.0 Q502 $41,513 G4-7U5MV Y 4950 74.14 145

350 1800 2300/4000 5011LL 77.6/44.6 95.4 Q509 $36,302 G4-7U5MV N 5200 75.14

350 1200 2300/4000 5011L 80.7/46.4 95.0 Q517 $40,554 G4-7U5MV Y 5500 80.39 148

400 3600 2300/4000 5011LS 83.8/48.2 95.0 Q503 $42,266 G4-7U5MV Y 5300 74.14 145

400 1800 2300/4000 5011LL 87.7/50.4 95.0 Q510 $38,116 G4-7U5MV Y 5800 75.14

400 1200 2300/4000 5011L 93.9/54 95.0 Q518 $43,272 G4-7U5MV Y 5700 80.39 148

450 3600 2300/4000 5011LS 93.9/54 95.4 Q504 $44,106 G4-7U5MV Y 5550 74.14 145

450 1800 2300/4000 5013S 99.1/57 95.0 Q511 $43,492 G4-7U5MV N 6500 85.13

450 1200 2300/4000 5013S 103.7/59.6 95.0 Q519 $47,547 G4-7U5MV N 6600 85.13 148

500 3600 2300/4000 5013ST 103.8/59.7 95.4 Q505 $47,559 G4-7U5MV Y 6350 83.13 145

500 1800 2300/4000 5013S 109.4/62.9 95.0 Q512 $46,369 G4-7U5MV N 7000 85.13

500 1200 2300/4000 5013S 114.6/65.9 95.0 Q520 $48,693 G4-7U5MV N 7150 85.13 148

600 3600 2300/4000 5013ST 124.5/71.6 95.4 Q506 $49,136 G4-7U5MV N 6700 83.13 145

600 1800 2300/4000 5013S 130.4/75 96.2 Q513 $55,844 G4-7U5MV Y 7150 85.13

600 1200 2300/4000 5013S 138.3/79.5 95.0 Q521 $50,855 G4-7U5MV N 7150 85.13 149

Notes:145 CCW rotation facing opposite drive end. For CW fans use Part #148C8070AA1; except for 350 HP 3600 RPM motors use #148C8070BA1148 Roller bearing on drive end. High strength shaft material. For belted loads only. Refer to Belt Drive Table in Application Guide.149 Class F rise at 1.0 SF only

probe1
New Stamp
Page 11: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Qua

ntum

™ L

MV—

TEFC

7.9

Quantum™ LMV—TEFCSevere Duty Medium Voltage

Typical Performance Data

Volts: 4000 HP: 200-600

HPFL

RPMNP FLA

Design LRA

Code KVA/HP

FLT (lb-ft)

LRT (lb-ft)

BDT (lb-ft)

NP Eff. Full

Load

75% Load Eff.

50% Load Eff.

NP PF Full

Load

75% Load

Power Factor

50% Load

Power Factor

Max KVAR

200 1185 26.8 156.4 G 885.3 1183.6 2299.1 95.0 95.4 95.2 84.5 81.0 72.4 58.2

250 3575 30.6 272.5 J 367.0 521.5 1328.2 95.0 94.3 92.9 92.5 90.5 85.0 49.2

250 1785 32.0 177.6 G 736.3 736.3 1766.4 95.0 95.1 94.6 88.5 87.0 81.5 52.7

250 1190 33.3 195.4 G 1103.5 1270.1 2774.2 95.0 95.4 95.1 85.0 82.0 74.0 69.4

300 3575 36.5 244.5 G 440.6 338.8 1198.4 95.0 94.8 93.7 93.0 92.1 88.5 46.5

300 1780 38.0 209.1 G 883.7 911.1 2067.0 95.0 95.5 95.2 89.5 88.0 83.1 57.6

300 1190 39.4 241.9 G 1323.6 1666.4 3399.0 95.4 95.8 95.6 86.0 83.0 75.4 78.6

350 3575 42.4 281.0 G 514.2 405.7 1376.0 95.0 95.2 94.3 93.5 92.7 89.5 50.1

350 1785 44.6 280.4 G 1029.1 1240.1 2790.9 95.4 96.0 95.5 88.5 86.5 80.2 77.7

350 1190 46.4 276.9 G 1544.8 1884.7 3934.6 95.0 95.9 95.7 85.5 82.8 75.2 92.3

400 3575 48.2 318.4 G 587.8 485.5 1558.3 95.0 95.5 94.8 94.0 93.4 90.8 51.7

400 1785 50.4 290.1 G 1178.1 1407.8 2808.6 95.0 96.1 95.8 90.0 88.8 84.5 70.9

400 1190 54.0 342.2 G 1763.7 2273.4 4910.1 95.0 96.0 95.7 84.0 80.5 71.5 120.8

450 3570 54.0 354.8 G 661.4 560.9 1737.5 95.4 95.7 95.1 94.0 93.7 91.3 55.0

450 1785 57.0 345.6 G 1324.0 1635.1 3388.1 95.0 96.4 96.0 89.5 88.1 83.0 86.8

450 1190 59.6 355.7 G 1985.9 2452.6 5081.9 95.0 96.2 96.0 85.5 82.9 75.3 117.1

500 3570 59.7 393.0 G 734.8 637.1 1936.9 95.4 96.0 95.4 94.5 94.0 91.8 58.1

500 1785 63.3 377.0 G 1471.5 1807.0 3684.6 95.0 96.5 96.2 89.5 88.4 83.6 92.6

500 1190 65.9 397.2 G 2206.8 2831.3 5640.6 95.0 96.3 96.2 86.0 83.5 76.3 125.2

600 3575 71.6 495.5 G 881.7 841.1 2447.6 95.4 96.3 95.9 94.5 94.1 91.9 69.6

600 1785 75.0 614.7 H 1762.3 3184.5 5917.8 96.2 96.8 96.5 89.5 86.7 79.7 138.0

600 1190 79.5 485.8 G 2649.0 3499.3 6945.7 95.0 96.3 96.2 85.5 83.0 75.4 155.8

probe1
New Stamp
Page 12: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

7.10

Quantum

™ LM

V—TEFC

Quantum™ LMV—TEFC

Dimensions

Dimensions refer to drawings on following page

Frame 500, Totally Enclosed Fan Cooled

Frame

Shaft Mounting

A B C D3 G J K L O P

Keyway Key Length N-W U1 V2Width Depth E H BA 2F 2XF

508L 1.000 0.500 10.00 12.00 3.875 11.50 10.00 1.07 8.50 - 25.00 23.00 31.90 72.39 12.50 1.35 7.00 8.36 37.88 30.80 30.45

508LL 0.875 0.437 5.00 6.75 3.375 6.50 10.00 1.07 8.50 - 25.00 23.00 31.90 67.14 12.50 1.35 7.00 8.36 37.88 30.80 30.45

508LS 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 8.50 - 25.00 23.00 31.90 66.14 12.50 1.35 7.00 8.36 37.88 30.80 30.45

509L 1.000 0.500 10.00 12.00 3.875 11.50 10.00 1.07 8.50 28.00 - 23.00 31.90 72.39 12.50 1.35 7.00 8.36 37.88 30.80 30.45

509LL 0.875 0.437 5.00 6.75 3.375 6.50 10.00 1.07 8.50 28.00 - 23.00 31.90 67.14 12.50 1.35 7.00 8.36 37.88 30.80 30.45

509LS 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 8.50 28.00 - 23.00 31.90 66.14 12.50 1.35 7.00 8.36 37.88 30.80 30.45

5010L 1.000 0.500 10.00 12.00 3.875 11.50 10.00 1.07 8.50 - 32.00 23.00 39.90 80.39 12.50 1.35 7.00 10.00 41.88 30.80 30.45

5010LL 0.875 0.437 5.00 6.75 3.375 6.50 10.00 1.07 8.50 - 32.00 23.00 39.90 75.14 12.50 1.35 7.00 10.00 41.88 30.80 30.45

5010LS 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 8.50 - 32.00 23.00 39.90 74.14 12.50 1.35 7.00 10.00 41.88 30.80 30.45

5011L 1.000 0.500 10.00 12.00 3.875 11.50 10.00 1.07 8.50 36.00 - 23.00 39.90 80.39 12.50 1.35 7.00 10.00 41.88 30.80 30.45

5011LL 0.875 0.437 5.00 6.75 3.375 6.50 10.00 1.07 8.50 36.00 - 23.00 39.90 75.14 12.50 1.35 7.00 10.00 41.88 30.80 30.45

5011LS 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 8.50 36.00 - 23.00 39.90 74.14 12.50 1.35 7.00 10.00 41.88 30.80 30.45

5012S 1.000 0.500 5.50 7.75 3.875 7.50 10.00 1.07 8.50 - 40.00 23.00 48.90 85.14 12.50 1.35 7.00 10.00 46.38 30.80 30.45

5012ST 0.750 0.375 4.00 5.75 2.875 5.50 10.00 1.07 8.50 - 40.00 23.00 48.90 83.13 12.50 1.35 7.00 10.00 46.38 30.80 30.45

5013S 1.000 0.500 5.50 7.75 3.875 7.50 10.00 1.07 8.50 45.00 - 23.00 48.90 85.14 12.50 1.35 7.00 10.00 46.38 30.80 30.45

5013ST 0.750 0.375 4.00 5.75 2.875 5.50 10.00 1.07 8.50 45.00 - 23.00 48.90 83.13 12.50 1.35 7.00 10.00 46.38 30.80 30.45

Frame 500, Totally Enclosed Fan Cooled with C Face

Frame

Shaft Mounting

A B C D3 G J K L O P

Keyway Key Length N-W U1 V2Width Depth E H BA 2F 2XF

5010LSC 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 - - 32.00 23.00 39.90 75.09 12.50 1.35 7.00 10.00 41.88 30.80 30.45

5011LSC 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 - 36.00 - 23.00 39.90 75.09 12.50 1.35 7.00 10.00 41.88 30.80 30.45

5012STC 0.750 0.375 4.00 5.75 2.875 5.50 10.00 1.07 - - 40.00 23.00 48.90 84.09 12.50 1.35 7.00 10.00 46.38 30.80 30.45

5013STC 0.750 0.375 4.00 5.75 2.875 5.50 10.00 1.07 - 45.00 - 23.00 48.90 84.09 12.50 1.35 7.00 10.00 46.38 30.80 30.45

Conduit Box Dimensions

FrameMax.

FL Amps5Approx. Volume AA AB AC4 AD4 AF XL XN R

508-5013 400 1260 2-4.00 21.53 18.16 6.41 9.42 12.39 16.25 34.03

508-5013 600 2500 2-4.00 22.74 19.19 6.38 - 12.00 22.69 35.24

508-5013 1200 5700 3-3.00 27.75 22.80 3.71 8.66 20.00 20.00 40.25

Notes:1 Tolerance on “U” dimension will be +0.000 inch - 0.0012 Dimension “V” represents length of straight part of shaft extension3 Tolerance on “D” dimension will be + 0.000 inch - 0.060 inch4 Dimension to AA hole5 Conduit box size is determined by full load amps

Providing mounting conditions permit, conduit box may be turned so that entrance can be made upward, downward or from either side

probe1
New Stamp
Page 13: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Qua

ntum

™ L

MV—

TEFC

7.11

Quantum™ LMV—TEFC

Dimensions

Frame dimensions on previous page

Frame 500, Totally Enclosed Fan Cooled

Frame 500, Totally Enclosed Fan Cooled with C Face

probe1
New Stamp
Page 14: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

7.12

449 Frame TEFC

449 Frame TEFCSevere Duty Medium Voltage

Standard Features

HP Range 125-200

Poles 2,4,6

Voltage 2300 (200HP 4 pole 2300/4000V)

Efficiency Premium

NEMA Design B

Altitude 3300 ft

Ambient 40°C, Alternate rating 65°C @ 1.0 SF except as noted

Balance/Vibration 0.055 in/sec Ball Bearing; Roller Bearing 6 Pole 0.0005 in (P-P)

Bearing Caps Both Ends

Bearing Protection Shaft Slinger Both Ends

Bearing Type Single Shielded Ball; 125HP & 150HP 6 pole have DE Roller Bearing

Conduit Box Cast Iron; 200HP 4 pole Fabricated Steel

Drain Stainless Steel T Drains in lowest section of both endshields

Enclosure TEFC

End Shield Cast Iron

Fan Bidirectional Non Sparking Plastic

Fan Cover Cast Iron

Fasteners SAE Grade 5

Frame Material Cast Iron

Frame Size 447/449

Frequency 60 Hz

Ground Ground in conduit box

Insulation Class Class F

Insulation System Epoxy VPI

Inverter Capabilities Consult Factory

L10 Bearing Life Direct Coupled: 130,000 hrs 4&6 pole; 65,000 hrs 2 pole; Belted 26,280 hrs

Leads Permanently Numbered, Non-wicking

Lifting Means Two (2) cast in lifting lugs

Lubrication Ball Bearing Polyurea

Mounting Foot mounted F1 only

Mounting Holes 2 per foot

Nameplate 316 Stainless Steel

Paint Epoxyester Buff

Relubrication Yes, both ends; extended through the fan cover

Rotor Cast Aluminum

Service Factor 1.15

Shaft Material 2&4 Pole AISI 1045; 6 Pole AISI 4140

Temperature Rise 80°C @ 1.0 SF

Tests NEMA Routine; IEEE 112 Method B

Time Rating Continuous

Warranty 36 months from date of purchase or 42 months from date of shipment, whichever occurs first

probe1
New Stamp
Page 15: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

449

Fram

e TE

FC

7.13

449 Frame TEFCSevere Duty Medium Voltage

Pricing

449 Frame

HP RPM Volts Frame FLA Nom. Eff. Cat. No. List PricePrice

Symbol Norm. Stk. Wt. (lbs) C Dim. (in) Notes

125 3600 2300 447TS 26.9 93.0 E9520 $18,884 G4-7TAN N 2490 50.06

125 1800 2300 449T 28.8 95.0 E9523 $18,691 G4-7TAN N 2490 53.81

125 1200 2300 449T 32.1 94.1 E9526 $19,024 G4-7TAN N 2750 53.81 148

150 3600 2300 449TS 32.1 93.0 E9521 $20,182 G4-7TAN Y 2610 50.06

150 1800 2300 449T 34.8 95.0 E9524 $19,318 G4-7TAN Y 2610 53.81

150 1200 2300 449T 38.3 94.1 E9527 $19,636 G4-7TAN N 2750 53.81 148

200 3600 2300 449TS 42.8 93.6 E9522 $21,609 G4-7TAN Y 2610 50.06 149, 150

200 1800 2300/4000 449T 45.2/26.0 95.0 E9525 $20,955 G4-7TAN Y 2720 53.81 150

Notes:148 Roller bearing on drive end. High strength shaft material. For belted loads only. Refer to Belt Drive Table in Application Guide.149 Class F rise @ 1.0 SF only150 Does not meet alternate rating of 65°C @ 1.0 SF

probe1
New Stamp
Page 16: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

7.14

449 Frame TEFC

449 Frame TEFCSevere Duty Medium Voltage

Typical Performance Data

Volts: 2300, 2300/4000 HP: 125-200

HPFL

RPMNP FLA

Design LRA

Code KVA/HP

FLT (lb-ft)

LRT (lb-ft)

BDT (lb-ft)

NP Eff. Full

Load

75% Load Eff.

50% Load Eff.

NP PF Full

Load

75% Load

Power Factor

50% Load

Power Factor

Max KVAR

125 3570 26.9 171.2 G 183.8 309.3 400.5 93.0 93.0 91.9 93.5 93.5 91.9 14.1

125 1785 28.8 165.4 G 367.7 696.8 813.7 95.0 95.1 94.4 85.5 82.4 74.6 34.7

125 1190 32.1 176.8 G 552.0 999.7 1137.1 94.1 94.4 93.7 77.5 72.9 62.4 49.7

150 3570 32.3 212.9 G 220.5 409.2 499.4 93.0 93.7 92.8 93.5 93.8 92.2 16.5

150 1785 34.8 209.8 G 441.0 903.2 1034.6 95.0 95.3 94.7 85.0 81.9 73.6 43.2

150 1190 38.3 215.5 G 662.6 1291.4 1401.4 94.1 94.6 94.0 78.0 73.5 63.3 58.0

200 3570 42.8 274.4 G 294.3 537.1 648.9 93.6 94.2 93.6 93.5 93.9 92.4 21.3

200 1785 26.0 154.8 G 587.6 998.3 1275.1 95.0 95.2 94.8 87.0 85.0 78.4 48.2

probe1
New Stamp
Page 17: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

449 Frame TEFCSevere Duty Medium Voltage

Dimensions

449 Frame, Totally Enclosed Fan Cooled

Frame

Shaft Mounting

A B C D3 G J K L O P

Keyway Key Length N-W U1 V2Width Depth E H BA BS 2F 2XF

447TS 0.625 0.625 3.00 4.75 2.375 4.50 9.00 0.81 7.50 12.50 25.00 20.00 20.00 27.30 50.06 11.00 1.47 2.61 8.91 25.31 22.98 23.08

449TS 0.625 0.625 3.00 4.75 2.375 4.50 9.00 0.81 7.50 12.50 25.00 20.00 20.00 27.30 50.06 11.00 1.47 2.61 8.91 25.31 22.98 23.08

449T 0.875 0.875 6.88 8.50 3.375 8.25 9.00 0.81 7.50 12.50 25.00 20.00 20.00 27.30 58.31 11.00 1.47 2.61 8.91 25.31 22.98 23.08

Conduit Box Dimensions

FrameMax.

FL Amps5Approx. Volume AA AB AC4 AF XL XN

447-449 250 700 8-3.00 20.81 16.68 7.00 12.14 10.50

447-449 250 2500 2-4.00 22.05 16.93 7.78 13.68 27.25

Notes:1 Tolerance on “U” dimension will be +0.000 inch - 0.0012 Dimension “V” represents length of straight part of shaft extension3 Tolerance on “D” dimension will be + 0.000 inch - 0.060 inch4 Dimension to AA hole5 Conduit box size is determined by full load amps

Providing mounting conditions permit, conduit box may be turned so that entrance can be made upward, downward or from either side

449

Fram

e TE

FC

7.15

probe1
New Stamp
Page 18: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

GE Energy Section 7 – Medium Voltage

7.1 Data subject to change without notice. GEP-500U 01/10 www.gemotors.com 800 541 7191

Medium Voltage WP-II Above NEMA (2300/4000 Volts) 509-5011 Frames

Standard Features

HP Range 400 - 800

Poles 2, 4

Voltage 2300/4000

Efficiency Standard

NEMA Design As noted

Altitude 1000 meters

Ambient 40 degree C

Balance/Vibration Standard per NEMA MG1

Bearing Caps Ball Bearing only

Bearing Temp Device 100 Platinum RTD both bearings

Bearing Type Ball or Sleeve as noted

Conduit Box 2500 cu in

Constant Level Oilers Provided on sleeve bearings

Enclosure WPII

End Shield Cast iron

Fasteners SAE

Frame Material Cast iron

Frame Size 509 - 5011

Frequency 60 Hz

Ground Ground in conduit box and frame

Insulation Class Class F

Insulation System Form coil epoxy VPI

Inverter Capabilities Consult Factory

Leads 6 leads

Lifting Means Four (4) cast in lifting lugs

Lubrication Ball bearing Polyurea, Sleeve bearing oil

Mounting Foot mounted F1 only (not convertible to F2)

Mounting Holes One per foot

Nameplate Stainless Steel

Paint Epoxyester Gray

Relubrication Yes, both ends

Roller Bearing Field conversion available

Rotor Aluminum

Service Factor 1.15

Shaft Material ANSI 1045

Space Heater Thermostatically controlled space heaters, 115 volt, 200 watt. Leads to a Condulet

Stator Temp Device 100 platinum Stator RTD’s, leads to accessory box

Temperature Rise As noted

Tests NEMA Routine; IEEE 112 Method B

Time Rating Continuous

Vertical Jack Screws Standard

Warranty 12 months from date of installation or 18 months from date of manufacture, whichever occurs first

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Medium Voltage WP-IIAbove NEMA (2300/4000 Volts)509-5011 Frames

Standard Features

7.16

Medium

Voltage

Page 19: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

GE Energy Section 7 – Medium Voltage

7.2 Data subject to change without notice. GEP-500U 01/10 www.gemotors.com 800 541 7191

Medium Voltage WP-II Above NEMA (2300/4000 Volts) 509-5011 Frames

Pricing and Kits

Weather Protected II

HP RPM Volts Frame SF FLA Cat. No. GE WP-II List Price Price Symbol Norm. Stk. Wt. (lbs)

C Dim. (in.) Notes

400 1800 2300/4000 509L 1.15 86.4/49.7 S3405 $34,264 G6-7DAN Y 3620 56.9 6

450 1800 2300/4000 509L 1.15 97.7/56.2 S3405 $34,264 G6-7DAN Y 3620 56.9

500 1800 2300/4000 509L 1.15 109.6/63.0 S3405 $34,264 G6-7DAN Y 3620 56.9

400 3600 2300/4000 509LS 1.15 86.4/49.7 S3406 $34,977 G6-7DAN Y 3620 50.65 6

450 3600 2300/4000 509LS 1.15 97.2/55.9 S3406 $34,977 G6-7DAN Y 3620 50.65

500 3600 2300/4000 509LS 1.15 108.2/62.2 S3406 $34,977 G6-7DAN Y 3620 50.65

600 3600 2300/4000 509LS 1.15 132.0/75.9 S3406 $34,977 G6-7DAN Y 3620 50.65 133

400 3600 2300/4000 509LS 1.15 86.4/49.7 S3427 $37,477 G6-7DAN Y 3620 50.65 4,6

450 3600 2300/4000 509LS 1.15 97.2/55.9 S3427 $37,477 G6-7DAN Y 3620 50.65 4

500 3600 2300/4000 509LS 1.15 108.2/62.2 S3427 $37,477 G6-7DAN Y 3620 50.65 4

600 3600 2300/4000 509LS 1.15 132.0/75.9 S3427 $37,477 G6-7DAN Y 3260 50.65 4, 133

500 1800 2300/4000 5011L 1.15 107.3/61.7 S3411 $43,009 G6-7DAN Y 4710 64.9 6

600 1800 2300/4000 5011L 1.15 129.2/74.3 S3411 $43,009 G6-7DAN Y 4710 64.9 133

700 1800 2300/4000 5011L 1.15 153.0/88.0 S3411 $43,009 G6-7DAN Y 4710 64.9 133

600 3600 2300/4000 5011LS 1.15 127.1/73.1 S3430 $46,155 G6-7DAN Y 4710 58.65 4, 133

700 3600 2300/4000 5011LS 1.15 149.0/85.7 S3430 $46,155 G6-7DAN Y 4710 58.65 4, 133

800 3600 2300/4000 5011LS 1.15 172.9/99.4 S3430 $46,155 G6-7DAN Y 4710 58.65 4, 133

Bearing Conversion Kit Designed to convert drive end ball bearing to roller bearing with the recommended ISO roller bearing. For 509-5011 GE frames (4, 6, and 8 pole only) stock motors. Roller bearing supplied. Contact factory for eligible models.

Cat. No. Part No. Frame List Price Price Symbol Norm. Stk.

A927 249A4321AG-G01 509-5011 $360 G6-7KITS N

Notes: 4 Sleeve Bearing 6 NEMA Design A 133 Above NEMA Defined Electrical Design All Ratings are foot mounted F1 only (not convertible to F2) Catalog number S3405 has nameplate stamping for 400HP, 450HP and 500HP ratings Catalog number S3406 has nameplate stamping for 400HP, 450HP, 500HP and 600HP ratings Catalog number S3427 has nameplate stamping for 400HP, 450HP, 500HP and 600HP ratings—all with sleeve bearings Catalog number S3411 has nameplate stamping for 500HP, 600HP and 700HP ratings Catalog number S3430 has nameplate stamping for the 600HP, 700HP and 800HP ratings

Notes: Application of this kit requires load confirmation with factory and is for the 320 bearing size

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Medium Voltage WP-IIAbove NEMA (2300/4000 Volts)509-5011 Frames

Pricing and Kits

Med

ium

Vol

tage

7.17

Page 20: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

ygrenEEG Section 7 – Medium Voltage

01/10U005-PEG.ecitontuohtiwegnahcottcejbusataD3.7www.gemotors.com

1917145008

Medium Voltage WP-II Above NEMA (2300/4000 Volts)

Dimensions

Weather Protected II

500 Frame

Dimensions in Inches

Shaft Mounting

Keyway

Frame

Approx. Net Wt. In

Lbs. Width Depth Key

Length N-W U (1) V (2) BA D (3) E F H A B C G J K L O P

509L 3300 1.000 0.500 10.0 12.00 3.875 11.75 8.5 12.5 10 14.0 1.06 26 32.6 56.90 1.1 5 6.5 22.40 45.26 42.2

509LS 3300 0.625 0.312 4.0 5.75 2.625 5.50 8.5 12.5 10 14.0 1.06 26 32.6 50.65 1.1 5 6.5 22.40 45.26 42.2

509LL 3300 0.875 0.437 5.0 6.75 3.375 6.50 8.5 12.5 10 14.0 1.06 26 32.6 51.65 1.1 5 6.5 22.40 45.26 42.2

5011L 4100 1.000 0.500 10.0 12.00 3.875 11.75 8.5 12.5 10 18.0 1.06 23 40.6 64.90 1.1 5 6.5 26.40 45.26 42.2

5011LS 4100 0.625 0.312 4.0 5.75 2.625 5.50 8.5 12.5 10 18.0 1.06 26 40.6 58.65 1.1 5 6.5 26.40 45.26 42.2

5011LL 4100 0.875 0.437 5.0 6.75 3.375 6.50 8.5 12.5 10 18.0 1.06 26 40.6 59.65 1.1 5 6.5 26.40 45.26 42.2

5013ST 5350 0.750 0.375 4.0 5.75 2.875 5.50 8.5 12.5 10 22.5 1.06 26 49.6 67.50 1.1 5 6.5 30.75 45.26 42.2

5013S 5350 1.000 0.500 5.5 7.75 3.875 7.50 8.5 12.5 10 22.5 1.06 26 49.6 69.50 1.1 5 6.5 30.75 45.26 42.2

5013LS 5350 0.625 0.312 4.0 5.75 2.625 5.50 8.5 12.5 10 22.5 1.06 26 49.6 67.50 1.1 5 6.5 30.75 45.26 42.2

Conduit Box Dimensions

Motors are depicted with representative conduit box. For specific dimensions or a complete motor outline drawing contact your authorized GE outlet.

Notes: 1 Shaft tolerance is +0.000 inch -0.001 inch 2 “V” represents length of straight extension of shaft 3 Tolerance on “D” dimensions will be +0.000 inches -0.060 inch 4 Dimension to AA hole

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Medium Voltage WP-IIAbove NEMA (2300/4000 Volts)

Dimensions

7.18

Medium

Voltage

Page 21: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Medium VoltageAbove NEMA (2300/4000 Volts)

Standard Features

7. Data subject to change without notice. GEP-500U 01/10 www.gemotors.com

800 541 7191

Med

ium

Vol

tage

7.19

Page 22: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy Section 7 – Medium Voltage

7.5 Data subject to change without notice. GEP-500U 01/10 www.gemotors.com 800 541 7191

Medium Voltage Pegasus™ MHV - WPII

Pricing (Please refer to your GE contact for ordering information)

Pegasus™ MHV—Weather Protected II

HP RPM Volts Frame FLA List Price Price Symbol Norm. Stk. Wt. (lbs) C Dim. (in.) Notes

800 1800 2300/4000 8210 181/104 $100,211 G8-9PWII N 7500 76.5 128, 137

800 1800 2300/4000 8210 181/104 $90,103 G8-9PWII N 7500 76.5 137

900 3600 2300/4000 8210 196/113 $118,501 G8-9PWII N 7000 65.01 128, 137

900 3600 2300/4000 8210 196/113 $108,393 G8-9PWII N 7000 65.01 137

900 1800 2300/4000 8210 201/116 $103,933 G8-9PWII N 7500 76.5 128, 137

900 1800 2300/4000 8210 201/116 $93,825 G8-9PWII N 7500 76.5 137

1000 3600 2300/4000 8212 217/125 $109,523 G8-9PWII N 8500 75.01 137

1000 1800 2300/4000 8210 221/127 $108,588 G8-9PWII N 7500 76.5 128, 137

1000 1800 2300/4000 8210 221/127 $98,482 G8-9PWII N 7500 76.5 137

1250 3600 2300/4000 8212 272/156 $112,912 G8-9PWII N 8500 75.01 137

1250 1800 2300/4000 8212 276/159 $116,039 G8-9PWII N 9200 85.5 128, 137

1250 1800 2300/4000 8212 276/159 $105,932 G8-9PWII N 9200 85.5 137

1500 3600 2300/4000 8212 334/192 $118,563 G8-9PWII N 8500 75.01 137

1500 1800 2300/4000 8212 330/189 $125,351 G8-9PWII N 9200 85.5 128, 137

1500 1800 2300/4000 8212 330/189 $115,245 G8-9PWII N 9200 85.5 137

1750 3600 2300/4000 8213 382/220 $155,397 G8-9PWII N 9300 82.5 114, 128, 137

1750 1800 2300/4000 8311 382/219 $136,806 G8-9PWII N 12000 86 128

1750 1800 2300/4000 8311 382/219 $124,678 G8-9PWII N 12000 86

2000 3600 2300/4000 8213 431/248 $161,378 G8-9PWII N 9300 82.5 114, 128, 137

2000 1800 2300/4000 8311 446/257 $143,638 G8-9PWII N 12000 86 128

2000 1800 2300/4000 8311 446/257 $131,509 G8-9PWII N 12000 86

2250 3600 2300/4000 8213 484/279 $170,017 G8-9PWII N 9300 82.5 114, 128, 137

2250 1800 2300/4000 8313 497/286 $170,425 G8-9PWII N 16000 101 128

2250 1800 2300/4000 8313 497/286 $157,398 G8-9PWII N 16000 101

2500 3600 2300/4000 8313 531/305 $203,839 G8-9PWII N 13900 95 114, 128, 137

2500 1800 2300/4000 8313 549/316 $171,892 G8-9PWII N 16000 101 128

2500 1800 2300/4000 8313 549/316 $158,866 G8-9PWII N 16000 101

2750 1800 2300/4000 8313 602/346 $177,764 G8-9PWII N 16000 101 128, 137

2750 1800 2300/4000 8313 602/346 $164,738 G8-9PWII N 16000 101 137

3000 3600 2300/4000 8313 636/366 $209,516 G8-9PWII N 13900 95 114, 128, 137

3000 1800 2300/4000 8313 656/377 $186,572 G8-9PWII N 16000 101 128, 137

3000 1800 2300/4000 8313 656/377 $173,545 G8-9PWII N 16000 101 137

3500 3600 2300/4000 8313 741/426 $220,871 G8-9PWII N 13900 95 114, 128, 137

3500 1800 2300/4000 8313 763/439 $196,847 G8-9PWII N 16000 101 128, 137

3500 1800 2300/4000 8313 763/439 $183,821 G8-9PWII N 16000 101 137

4000 3600 2300/4000 8313 847/487 $228,439 G8-9PWII N 13900 95 114, 128, 137

Notes: 114 Fabricated Copper Bar Rotor 128 Split Sleeve Bearings 137 4140 shaft material

GE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Medium VoltagePegasus™ MHV—WPII

Pricing (Please refer to your GE contact for ordering information)

7.20

Medium

Voltage

Page 23: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

GE Energy Section 7 – Medium Voltage

7.6 Data subject to change without notice. GEP-500U 01/10 www.gemotors.com 800 541 7191

Medium Voltage Quantum™ LMV - TEFC

Pricing (Please refer to your GE contact for ordering information)

Quantum™ LMV - TEFC

HP RPM Volts Frame FLA List Price Price Symbol Norm. Stk. Wt. (lbs) C Dim. (in.) Notes

900 3600 2300/4000 7010 192/111 $156,830 G8-9QT N 9700 119.00 128

900 1800 2300/4000 7010 199/112 $141,244 G8-9QT N 9500 133.50 128

900 1800 2300/4000 7010 199/112 $129,520 G8-9QT N 9500 121.50

1000 3600 2300/4000 7011 212/122 $175,454 G8-9QT N 11400 119.00 128

1000 1800 2300/4000 7010 217/126 $144,827 G8-9QT N 10100 133.50 128

1000 1800 2300/4000 7010 217/126 $133,103 G8-9QT N 10100 121.50

1250 3600 2300/4000 7011 264/152 $190,720 G8-9QT N 12500 119.00 128

1250 1800 2300/4000 7010 266/154 $156,772 G8-9QT N 11000 133.50 128

1250 1800 2300/4000 7010 266/154 $145,046 G8-9QT N 11000 121.50

1350 3600 2300/4000 7011 284/164 $204,474 G8-9QT N 13000 119.00 128

1350 1800 2300/4000 7011 290/167 $165,882 G8-9QT N 12100 133.50 128

1350 1800 2300/4000 7011 290/167 $153,754 G8-9QT N 12100 121.50

1500 3600 2300/4000 7011 318/184 $205,985 G8-9QT N 13600 119.00 128

1500 1800 2300/4000 7011 320/185 $167,515 G8-9QT N 12700 133.50 128

1500 1800 2300/4000 7011 320/185 $155,792 G8-9QT N 12700 121.50

1750 1800 2300/4000 7011 375/214 $208,756 G8-9QT N 14100 133.50 114, 128, 137

1750 1800 2300/4000 7011 375/214 $197,032 G8-9QT N 14100 121.50 114, 137

2000 1800 2300/4000 7011 430/245 $221,521 G8-9QT N 15000 133.50 114, 128, 137

2000 1800 2300/4000 7011 430/245 $209,797 G8-9QT N 15000 121.50 114, 137

Notes: 114 Fabricated Copper Bar Rotor 128 Split Sleeve Bearings 137 4140 shaft material

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Medium VoltageQuantum™ LMV—TEFC

Pricing (Please refer to your GE contact for ordering information)

Med

ium

Vol

tage

7.21

Page 24: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

GE Energy Section 7 – Medium Voltage

7.7 Data subject to change without notice. GEP-500U 01/10 www.gemotors.com 800 541 7191

Medium Voltage Pegasus™ MHV— TEAAC

Pricing (Please refer to your GE contact for ordering information)

Pegasus™ MHV - TEAAC

HP RPM Volts Frame FLA List Price Price Symbol Norm. Stk. Wt. (lbs) C Dim. (in.) Notes 500 3600 2300/4000 8210 110/63 $139,035 G8-9PTAC N 8100 83.26 128, 137

500 3600 2300/4000 8210 110/63 $128,927 G8-9PTAC N 8100 83.26 137

600 3600 2300/4000 8210 132/76 $140,136 G8-9PTAC N 8100 83.26 128, 137

600 3600 2300/4000 8210 132/76 $130,030 G8-9PTAC N 8100 83.26 137

600 1800 2300/4000 8208 133/76 $120,897 G8-9PTAC N 7000 90.50 128, 137

600 1800 2300/4000 8208 133/76 $110,791 G8-9PTAC N 7000 90.50

700 3600 2300/4000 8210 153/88 $141,240 G8-9PTAC N 8100 83.26 128, 137

700 3600 2300/4000 8210 153/88 $131,134 G8-9PTAC N 8100 83.26 137

700 1800 2300/4000 8210 155/89 $122,740 G8-9PTAC N 8750 101.00 128

700 1800 2300/4000 8210 155/89 $112,634 G8-9PTAC N 8750 101.00

800 3600 2300/4000 8210 175/100 $141,240 G8-9PTAC N 8100 83.26 128, 137

800 3600 2300/4000 8210 175/100 $131,134 G8-9PTAC N 8100 83.26 137

800 1800 2300/4000 8210 177/102 $124,123 G8-9PTAC N 8750 101.00 128

800 1800 2300/4000 8210 177/102 $114,017 G8-9PTAC N 8750 101.00

900 3600 2300/4000 8212 197/114 $156,830 G8-9PTAC N 9950 93.26 137

900 1800 2300/4000 8210 200/115 $141,244 G8-9PTAC N 8750 101.00 128, 137

900 1800 2300/4000 8210 200/115 $129,520 G8-9PTAC N 8750 101.00 137

1000 3600 2300/4000 8212 219/126 $175,454 G8-9PTAC N 9950 93.26 137

1000 1800 2300/4000 8212 220/126 $144,827 G8-9PTAC N 10500 101.00 128, 137

1000 1800 2300/4000 8212 220/126 $133,103 G8-9PTAC N 10500 101.00 137

1250 3600 2300/4000 8212 271/156 $190,720 G8-9PTAC N 9950 93.26 137

1250 1800 2300/4000 8212 273/157 $156,772 G8-9PTAC N 10500 101.00 128, 137

1250 1800 2300/4000 8212 273/157 $145,046 G8-9PTAC N 10500 101.00 137

1500 3600 2300/4000 8213 326/187 $205,985 G8-9PTAC N 11500 102.00 114, 128, 137

1500 1800 2300/4000 8212 326/187 $167,515 G8-9PTAC N 10500 101.00 128, 137

1500 1800 2300/4000 8212 326/187 $155,792 G8-9PTAC N 10500 101.00 137

1750 3600 2300/4000 8213 380/218 $174,407 G8-9PTAC N 11500 102.00 114, 128, 137

1750 1800 2300/4000 8311 393/226 $208,756 G8-9PTAC N 13500 112.00 128

1750 1800 2300/4000 8311 393/226 $197,032 G8-9PTAC N 13500 112.00

2000 3600 2300/4000 8213 433/249 $178,023 G8-9PTAC N 12500 102.00 114, 128, 137

2000 1800 2300/4000 8313 444/255 $221,521 G8-9PTAC N 17500 130.00 128

2000 1800 2300/4000 8313 444/255 $209,797 G8-9PTAC N 17500 130.00

2250 3600 2300/4000 8313 483/278 $218,111 G8-9PTAC N 13500 117.00 114, 128, 137

2250 1800 2300/4000 8313 500/287 $179,625 G8-9PTAC N 17500 130.00 128

2250 1800 2300/4000 8313 500/287 $166,596 G8-9PTAC N 17500 130.00

2500 3600 2300/4000 8313 535/308 $226,383 G8-9PTAC N 13500 117.00 114, 128, 137

2500 1800 2300/4000 8313 547/315 $186,974 G8-9PTAC N 17500 130.00 128

2500 1800 2300/4000 8313 547/315 $173,947 G8-9PTAC N 17500 130.00

2750 1800 2300/4000 8313 601/346 $194,323 G8-9PTAC N 17500 130.00 128, 137

2750 1800 2300/4000 8313 601/346 $181,296 G8-9PTAC N 17500 130.00 137

3000 3600 2300/4000 8313 640/368 $229,691 G8-9PTAC N 14000 117.00 114, 128, 137

3000 1800 2300/4000 8313 656/377 $201,674 G8-9PTAC N 17500 130.00 128, 137

3000 1800 2300/4000 8313 656/377 $188,647 G8-9PTAC N 17500 130.00 137

Notes: 114 Fabricated Copper Bar Rotor 128 Split Sleeve Bearings 137 4140 shaft material

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Medium VoltagePegasus™ MHV—TEAAC

Pricing (Please refer to your GE contact for ordering information)

7.22

Medium

Voltage

Page 25: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

XW

V

AC

AB

XN

XL

2.20

B

BAF F

K

30 ∞

A

EE

J

D GU

C

L

XN

O

P

2.00

4.35

4.0 0

Dripproof Weather Protected II

AIR OUTLETBOTH ENDSEACH SIDE

(4)MOTORLIFTINGLUGS

AA HOLESFOR CONDUIT

KEYLENGTH

AIR INLETBOTH SIDES

.500-13,2 HOLESPROVIDED FORLIFTING TOPCOVER ONLY

REMOVABLECOVER FOR ACCESSTO FILTER(WHEN FURNISHED)

WINDINGACCESSORYLEADS BEHIN DCOVER

REAM FOR .50 DIA.DOWEL PIN ATINSTALLATION2 HOLES ON DIAGONALLYOPPOSITE FEET.

1"-11.5 NPSI2 HOLES

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

Medium VoltageAbove NEMA (2300/4000 Volts)

Dimensions

Med

ium

Vol

tage

7.23

Page 26: TABLE OF CONTENTS 7.0 High HP Low and Medium Voltageproii.ru/catalogs/qlmv_ge.pdf · 7.0 High HP Low and Medium Voltage 7.1 Quantum™ LMV - TEFC Low Voltage 7.7 Quantum™ LMV -

Section 7 – High HP Low and Medium VoltageGE Energy

Data subject to change without notice. GEP-500U 01/10 • www.gemotors.com • 800-541-7191

7.24

High H

P Low &

Medium

Voltage

Notes