table of contents - · pdf filebi-metric ® head/neck hip system. 12-162380 12-162381...

56
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reserved web site: www.biomet.com • eMail: [email protected] Form No. Y-BMT-812/051503/H Alliance ® Hip System Balance ® Hip System Bio-Moore ® II Hip System Mallory-Head ® Hip System Revision Hip System Stanmore Hip System Taperloc ® Hip System Table of Contents

Upload: phamcong

Post on 06-Feb-2018

258 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Alliance® Hip System

Balance® Hip System

Bio-Moore® II Hip System

Mallory-Head® Hip System

Revision Hip System

Stanmore™ Hip System

Taperloc® Hip System

Table of Contents

Page 2: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x
Page 3: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Answer®

Hip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Interlok® finish enhances cement-to-implant bonding.• 3˚ bi-planar taper to promote compressive loading vs. shear of the cement mantle.• Integrated A/P spacers to centralize proximally to allow for uniform cement mantle.• PMMA distal centralizer to guard against varus or valgus positioning.• Lateralized option— Morse taper is shifted 6mm medially without altering

leg length.• Duckbill collar stresses the medial calcar and helps prevent subsidence of the stem.• Reduced medial aspect allows for a 3.5mm proximal/medial cement mantle.• Alliance® instrumentation.

The Answer® Hip System is marketed for use with bone cement in the United States.Answer®, Alliance® and Interlok® are registered trademarks of Biomet, Inc.

Page 4: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Answer®HipSystem

162601162602162603162604162605

9 x 125mm11 x 135mm13 x 145mm15 x 155mm17 x 165mm

PartNumber Description

Answer®FemoralComponents

162501162502162503162504162505

LateralizedPartNumber

162656162640162657162641162658162642162659162643162660162644162661162646

9mm10mm11mm12mm13mm14mm15mm16mm17mm18mm19mm20mm

PartNumber Description

Answer®DistalStemPositioners

Page 5: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Bi-Metric® Head/NeckHip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Interlok® finish enhances cement-to-implant bonding.• 3˚ bi-planar taper to promote compressive loading vs. shear of the cement mantle.• Lateral flange holes for reattachment of trochanter.• PMMA distal centralizer guards against varus or valgus positioning.• Medial keel for rotational stability.• 34, 45, 55mm resection levels—9, 11, 13 and 15mm diameters.• 150mm, 200mm and 250mm lengths.• Alliance® instrumentation.

The Bi-Metric® Head/Neck Hip System is marketed for use with bone cement in the United States.Bi-Metric®, Interlok® and Alliance® are registered trademarks of Biomet, Inc.

Page 6: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Bi-Metric®Head/NeckHipSystem

12-16238012-16238112-16238212-16238312-16238412-16238512-16238612-16238712-162388

9 x 34 x 150mm11 x 34 x 150mm13 x 34 x 150mm9 x 45 x 150mm11 x 45 x 150mm13 x 45 x 150mm9 x 55 x 150mm11 x 55 x 150mm13 x 55 x 150mm

150mmPartNumber Description

162907162909162911162913162915162917

7mm9mm11mm13mm15mm17mm

PartNumber Description

PMMACenteringSleeves

12-16258012-16258212-16258412-16257412-16258612-16258812-16259012-16257612-16259212-16259412-16259612-162578

9 x 34 x 250mm11 x 34 x 250mm13 x 34 x 250mm15 x 34 x 250mm9 x 45 x 250mm11 x 45 x 250mm13 x 45 x 250mm15 x 45 x 250mm9 x 55 x 250mm11 x 55 x 250mm13 x 55 x 250mm15 x 55 x 250mm

250mmLeftPartNumber Description12-16258112-16258312-16258512-16257512-16258712-16258912-16259112-16257712-16259312-16259512-16259712-162579

250mmRightPartNumber

12-16248012-16248112-16248212-16248912-16248312-16248412-16248512-16249012-16248612-16248712-16248812-162491

9 x 34 x 200mm11 x 34 x 200mm13 x 34 x 200mm15 x 34 x 200mm9 x 45 x 200mm11 x 45 x 200mm13 x 45 x 200mm15 x 45 x 200mm9 x 55 x 200mm11 x 55 x 200mm13 x 55 x 200mm15 x 55 x 200mm

200mmPartNumber Description

Page 7: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Net-forged Ti alloy provides precise and consistent development of hip implants

and related instrumentation.• Proximal 1/3 PPS™ coated.• 3˚ bi-planar taper.• Collared in standard offset with neck angle of 140.̊ Non-collared in standard

offset with neck angle of 135˚ and 130˚ for lateralized option.• Offset option increases proportionally based on stem size (5 – 9mm of

additional offset).• Medialized insertion hole.• HA option over porous plasma spray.• Use only with Exact™ Alliance® Instrumentation.

Bi-Metric® X-Series Porous Primary Hip System

Bi-Metric®, Alliance®, Exact™ and PPS™ are trademarks of Biomet, Inc.

Page 8: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Bi-Metric®X-SeriesPorousPrimaryHipSystem

X21-180307X21-180308X21-180309X21-180310X21-180311X21-180312X21-180313X21-180314X21-180315X21-180316X21-180317X21-180318X21-180319X21-180320X21-180321

–X21-182308X21-182309X21-182310X21-182311X21-182312X21-182313X21-182314X21-182315X21-182316X21-182317X21-182318X21-182319X21-182320X21-182321

HA*StandardPartNumber HA*LateralizedPartNumber7mm8mm9mm

10mm11mm12mm13mm14mm15mm16mm17mm18mm19mm20mm21mm

Description

X180307X180308X180309X180310X180311X180312X180313X180314X180315X180316X180317X180318X180319X180320X180321

–X11-180308X11-180309X11-180310X11-180311X11-180312X11-180313X11-180314X11-180315X11-180316X11-180317X11-180318X11-180319X11-180320X11-180321

Non-CollaredPartNo. CollarlessLat.PartNo.7 x 115mm8 x 120mm9 x 125mm

10 x 130mm11 x 135mm12 x 140mm13 x 145mm14 x 150mm15 x 155mm16 x 160mm17 x 165mm18 x 170mm19 x 175mm20 x 180mm21 x 185mm

DescriptionCollaredPartNo.

X181307X181308X181309X181310X181311X181312X181313X181314X181315X181316X181317X181318X181319X181320X181321

* HA offered in collarless option only.

Page 9: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• Interlok® finish enhances cement-to-implant bonding.• Proximal 1/3 HA coated (Hydroxyapatite)—promotes bony ingrowth in the HA

coated grooved surface.• 3˚ bi-planar taper.• 50 micron coating of HA.• Large “V” shaped grooves on proximal 1/3 promotes bony interdigitation.• Collarless.• Alliance® instrumentation.

Bio-Groove®

HAHip System

Bio-Groove®, Interlok® and Alliance® are registered trademarks of Biomet, Inc.

Page 10: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Bio-Groove®HAHipSystem

11-16280711-16280811-16280911-16281011-16281111-16281211-16281311-16281411-16281511-16281611-16281711-16281811-162819

7 x 115mm8 x 120mm9 x 125mm

10 x 130mm11 x 135mm12 x 140mm13 x 145mm14 x 150mm15 x 155mm16 x 160mm17 x 165mm18 x 170mm19 x 175mm

PartNumber Description

Page 11: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Hip FractureHip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Interlok® finish enhances cement-to-implant bonding.• 3˚ bi-planar taper to promote compressive loading vs. shear of the cement mantle.• Duckbill collar stresses medial calcar and helps prevent subsidence.• 140˚ neck angle.• Can be cemented or press-fit.• If press-fitting, special gold-nitrided Hip Fracture broaches must be used.• Sizing is one-to-one. Example: If you template to a 10, ream and broach to a 10.

If you are cementing, implant an 8mm stem. If you are press-fitting, implant a 10mm stem.

• PMMA centering sleeve centralizes stem within the canal.• Alliance® instrumentation.Interlok® and Alliance® are registered trademarks of Biomet, Inc.

Page 12: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

HipFractureHipSystem

162900162901162902162903162904

8mm10mm12mm14mm16mm18mm

PartNumber Description

HipFractureFemoralComponents

31-47390031-47390131-47390231-47390331-47390431-473905

BroachPartNumber

162908162910162912162914162916

PMMACenteringSleeve

Page 13: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged cobalt chrome— approximately twice the fatigue strength of cast CoCr.• Interlok® finish enhances cement-to-implant bonding.• 3˚ bi-planar taper to promote compressive loading vs. cylindrical designs.• Integrated A/P and medial spacers allow for centralized placement and an even

cement mantle.• Cobra flare for cement pressurization.• Duckbill collar stresses medial calcar and helps prevent subsidence of stem.• PMMA distal centralizer for more consistent cement mantle.• Alliance® instrumentation.• 99.3% survivorship at mean follow-up of 7 years (Bankston; Total Joint

and Sports Medicine Symposium, 2001).*Also offered in a lateralized version where the Morse taper is shifted 6mm medially. When using the lateralized option, the offset is increased, thereby tightening soft tissues without affecting leg length.

Integral®

Centralizer*Hip System

Integral®, Interlok® and Alliance® are registered trademarks of Biomet, Inc.

Page 14: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Integral®CentralizerHipSystem

12-16260912-16261112-16261312-16261512-162617

9 x 125mm11 x 135mm13 x 145mm15 x 155mm17 x 165mm

PartNumber Description

Integral®FemoralComponents

11-16270911-16271111-16271311-16271511-162717

LateralizedPartNumber

162656162640162657162641162658162642162659162643162660162644162661162646

9mm10mm11mm12mm13mm14mm15mm16mm17mm18mm19mm20mm

PartNumber Description

DistalStemPositioners

Page 15: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Net-forged Ti alloy provides precise and consistent development of hip implants

and related instrumentation.• Extended level of PPS™ coating (tuxedo tail) creates a tight circumferential

“scratch-fit” that provides initial stability.• 3˚ bi-planar taper.• 140˚ neck angle (both standard and lateralized).• Broad lateral shoulder for rotational stability to promote compressive loading.• Porous coated duckbill collar stresses the medial calcar and helps prevent

subsidence of the stem.• Also offered in a reduced proximal profile (RPP) option to fit the “stove pipe”

femur. Exact™ RPP broaches (nitrided black) must be used.• Use only with Exact™ Alliance® Instrumentation.

Integral®

X-Series Porous PrimaryHip System

Integral, Alliance®, Exact™ and PPS™ are trademarks of Biomet, Inc.

Page 16: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Integral®X-SeriesPorousPrimaryHipSystem

X170307X170308X170309X170310X170311X170312X170313X170314X170315X170316X170317X170318X170319X170320X170321

–X11-170308X11-170309X11-170310X11-170311X11-170312X11-170313X11-170314X11-170315X11-170316X11-170317X11-170318X11-170319X11-170320X11-170321

PartNumber LateralizedPartNumber7 x 115mm8 x 120mm9 x 125mm

10 x 130mm11 x 135mm12 x 140mm13 x 145mm14 x 150mm15 x 155mm16 x 160mm17 x 165mm18 x 170mm19 x 175mm20 x 180mm21 x 185mm

Description

Page 17: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Osteocap rs®

Hip SystemDesignFeatures:• Forged Ti alloy.• Circumferential PPS™ coating on proximal 1/3 and under conical collar.• 30˚ proximal geometry for optimum physiological stress transfer coupled with

a 3˚ bi-planar taper.• Distal coronal slot to reduce stem stiffness and minimize distal point loading.• Four distal flutes enhance rotational stability.• 135˚ neck angle.• rs (Reduced Stiffness).• Alliance® instrumentation.• Must use cylindrical reamers, conical reamers, necks and reduced proximal

profile (RPP) broaches.The Osteocap rs® Hip System is marketed for noncemented use in skeletally mature patients undergoing primary hip replacement surgery as a result of noninflammatory degenerative joint disease.Osteocap rs®, Alliance® and PPS™ are trademarks of Biomet, Inc.

Page 18: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Osteocaprs®HipSystem

110109110110110111110112110113110114110115110117

31-11010931-11011031-11011131-11011231-11011331-11011431-11011531-110117

PartNumber ProvisionalNumber9 x 145mm

10 x 150mm11 x 150mm12 x 155mm13 x 155mm14 x 160mm15 x 160mm17 x 165mm

Description

Page 19: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• Proximal 40% circumferential PPS™ coating, while remainder of stem

is polished.• Bi-planar taper proximal 2/3 of implant. Cylindrical distally with multiple distal

splines providing increased rotational stability.• 130˚ neck angle.• 10˚ anteverted neck to aid in replicating normal anatomies.• Duckbill collar with porous coating on the bottom of the collar.• Distal coronal slot on sizes 11 and above.• Alliance® instrumentation with combination reamers.

Progressive™ Hip System

Progressive™, Alliance® and PPS™ are trademarks of Biomet, Inc.

Page 20: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Progressive™HipSystem

166314166316166318166320166322166324166326166328166330

9 x 125mm10 x 130mm11 x 135mm12 x 140mm13 x 145mm14 x 150mm15 x 155mm16 x 160mm17 x 165mm

RightPartNumber Description

166315166317166319166321166323166325166327166329166331

LeftPartNumber

Page 21: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Rx 90™ Smooth Hip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Smooth satin finish (17 Ra).• 3˚ bi-planar taper to promote compressive loading vs. shear of the cement mantle.• Reduced medial collar provides optimal calcar support.• Integrated PMMA proximal spacers located on the medial, anterior

and posterior aspects.• Large cement mantle—3.5mm proximal medially, 2.5mm proximal laterally.• PMMA distal centralizers are available in 1.5mm (standard) or 2.5mm (large) sizes.• 140˚ neck angle. Available in lateralized option—Morse taper is shifted 6mm

medially without altering leg length.• Alliance® instrumentation.

The Rx 90™ Primary Hip System is marketed for use with bone cement in the United States.Rx 90™and Alliance® are trademarks of Biomet, Inc.

Page 22: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Rx90™SmoothHipSystem

149019149021149023149025149027

9mm11mm13mm15mm17mm

1.5mmPartNumber Description

Rx90™SmoothCementSpacers

149029149031149033149035149037

2.5mmPartNumber

11-15900911-15901111-15901311-15901511-159017

9 x 125mm11 x 135mm13 x 145mm15 x 155mm17 x 165mm

LateralizedPartNumber Description

Rx90™SmoothFemoralComponents

159009159011159013159015159017

StandardPartNumber

Page 23: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Balance®

Hip SystemDesignFeatures:• Forged Ti alloy.• Proximal 40% PPS™ coating for enhanced bone ingrowth.• 3˚ bi-planar taper promotes compressive loading.• 5˚ proximal anterior build-up for maximum A/P fill.• 5˚ anteverted neck, right and left specific, aids in replicating normal anatomies.• 135˚ neck angle.• Middle 1/3 Interlok® finish and distal 1/3 is satin finish.• Simple “ream only” surgical technique.

The Balance® Hip System is marketed for non-cemented use in skeletally mature patients undergoing primary hip replacement surgery as a result of noninflammatory degenerative joint disease.Balance®, Interlok® and PPS™ are trademarks of Biomet, Inc.

Page 24: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Balance®HipSystem

Slots in distal portion of implant begin at size 16mm.

170096170097170098170099

31-20004031-20004131-20004231-200043

PartNumber ProvisionalNumber19 x 180mm Rt19 x 180mm Lt20 x 180mm Rt20 x 180mm Lt

Description

180000180001180002180003180004180005180006180007180008180009180010180011180012180013180014180015180016180017180018180019180020180021180022180023

31-20001331-20001431-20001531-20001631-20001731-20001831-20001931-20002031-20002131-20002231-20002331-20002431-20002531-20002631-20002731-20002831-20002931-20003031-20003131-20003231-20003331-20003431-20003531-200036

PartNumber ProvisionalNumber7 x 140mm Rt7 x 140mm Lt8 x 145mm Rt8 x 145mm Lt9 x 150mm Rt9 x 150mm Lt

10 x 155mm Rt10 x 155mm Lt11 x 160mm Rt11 x 160mm Lt12 x 165mm Rt12 x 165mm Lt13 x 170mm Rt13 x 170mm Lt14 x 175mm Rt14 x 175mm Lt15 x 180mm Rt15 x 180mm Lt16 x 180mm Rt16 x 180mm Lt17 x 180mm Rt17 x 180mm Lt18 x 180mm Rt18 x 180mm Lt

Description

Page 25: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• Interlok® finish enhances cement-to-implant bonding.• Type I Morse taper.• I-beam design for rotational stability.• Incorporates a lateral fin for rotational stability.• Offered in solid or fenestrated options.• Can press-fit or cement solid components, and can ONLY press-fit

fenestrated components.• Needs taper inserts for use with Endo II heads (5 neck lengths: -6, -3, Std.,

+3, and +6mm).• Compatible with all Biomet® acetabular components.

Bio-Moore®

IIHip System

Bio-Moore®, Interlok® and Biomet® are registered trademarks of Biomet, Inc.

Page 26: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Bio-Moore®IIHipSystem

139202139203139204139205

–139209139210139211

SolidPartNumber FenestratedPartNumber10 x 165mm12 x 165mm14 x 165mm16 x 165mm

Description

Page 27: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Mallory-Head® Interlok®

Hip SystemDesignFeatures:• Forged cobalt chrome— approximately twice the fatigue strength of cast CoCr.• Interlok® finish on proximal 1/3 of stem and the distal 2/3 of the stem is smooth.• 3˚ bi-planar taper to promote compressive loading vs. cylindrical designs.• Duckbill collar anchors the implant to the bone and directs the cement to the

distal canal.• Distal I-beam channel resists rotational forces.• Two 20˚ ribs located proximally on the anterior and posterior sides force cement

medially into compression.• PMMA centering sleeve used distally for central alignment in the canal.• Mallory-Head® cemented instrumentation.

The Mallory-Head® Interlok® Hip System is marketed for use with bone cement in the United States.Mallory-Head® and Interlok® are registered trademarks of Biomet, Inc.

Page 28: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Mallory-Head®Interlok®HipSystem

105606105607105609105611105613105615

PartNumber5/7 x 135mm7 x 140mm9 x 150mm11 x 160mm13 x 170mm15 x 180mm

Description

162907162909162911162913162915

PartNumber7mm9mm11mm13mm15mm

PMMACenteringSleeve

Page 29: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Mallory-Head® Porous PrimaryHip SystemDesignFeatures:• Forged Ti alloy.• PPS™ (Porous Plasma Spray) coating on proximal 1/3 of stem, middle 1/3 of stem is

roughened Interlok® finish, and distal 1/3 is smooth finish.• Dual tapered geometry provides a lateral to medial taper and a 3˚ included taper

from proximal to distal.• Proximal finned geometry—designed to minimize rotation due to torsional loads.• Standard—136˚ neck angle; lateralized—131˚ neck angle. Offset option increases

proportionately based on stem size (6 – 8mm of additional offset).• Provides quadrilateral fixation via: Lateral fin, anterior fin, posterior fin, and

medial contact.• HA option over PPS™ coating.• 99.5% survivorship at 11 years (Head, et al.; Orthopedics, 1999).Mallory-Head® , Interlok® and PPS™ are trademarks of Biomet, Inc.

Page 30: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Mallory-Head®PorousPrimaryHipSystem

9 x 150mm10 x 155mm11 x 160mm12 x 165mm13 x 170mm14 x 175mm15 x 180mm16 x 180mm17 x 180mm

11-10420911-10421011-10421111-10421211-10421311-10421411-10421511-10421611-104217

PartNumber Description

Mallory-Head®LateralizedPorousPrimary

11-10410611-10410711-10410811-10410911-10411011-10411111-10411211-10411311-10411411-10411511-10411621-10411721-10411821-104119

6 x 135mm7 x 140mm8 x 145mm9 x 150mm

10 x 155mm11 x 160mm12 x 165mm13 x 170mm14 x 175mm15 x 180mm16 x 180mm17 x 180mm18 x 180mm19 x 180mm

PartNumber Description

Mallory-Head®PorousPrimary

–––

21-10410921-10411021-10411121-10411221-10411321-10411421-10411521-10411621-10411721-10411821-104119

HAPartNumber

21-12430921-12431021-12431121-12431221-12431321-12431421-12431521-12431621-124317

HAPartNumber

Page 31: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• Proximal 1/3 of stem PPS™ coated, Interlok® finish distally for enhanced stability.• Collar design with 2˚ anterior bow.• Available in 200mm, 250mm and 300mm lengths (all bowed).• Alliance® instrumentation.

Bi-Metric®

Long StemHip System

The Bi-Metric® Revision Hip System is marketed for use with bone cement in the United States.Bi-Metric®, Interlok®, Alliance® and PPS™ are trademarks of Biomet, Inc.

Page 32: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Bi-Metric®LongStemHipSystem

162340162342162344162346162348

162350162352162354162356162358

162360162362162364162366162368

162341162343162345162347162349

162351162353162355162357162359

162361162363162365162367162369

PartNumberRight PartNumberLeft9 x 200mm11 x 200mm13 x 200mm15 x 200mm17 x 200mm

9 x 250mm11 x 250mm13 x 250mm15 x 250mm17 x 250mm

9 x 300mm11 x 300mm13 x 300mm15 x 300mm17 x 300mm

Description

Page 33: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• 70% PPS™ coated.• 3˚ bi-planar taper proximally to promote compressive loading, cylindrical

after 100mm.• Distal coronal slot to reduce thigh pain.• Porous coated duckbill collar stresses the calcar and prevents subsidence.• 140˚ neck angle.• Can be used as a primary or a short revision stem.• Also offered in a reduced proximal profile (RPP) option to fit the “stove pipe” femur (RPP broaches must be used).• Alliance® instrumentation.

Integral®

180Hip System

Integral® , Alliance® and PPS™ are trademarks of Biomet, Inc.

Page 34: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Integral®180HipSystem

166010166011166012166013166014166015166016166017166018166019

–11-16601111-16601211-16601311-16601411-16601511-16601611-16601711-16601811-166019

PartNumber ReducedProximalProfilePartNumber10 x 180mm11 x 180mm12 x 180mm13 x 180mm14 x 180mm15 x 180mm16 x 180mm17 x 180mm18 x 180mm19 x 180mm

Description

Page 35: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• Titanium PPS™ coating proximal 40% of stem for enhanced

bone ingrowth.• Proximal calcar loading implant with distal interlocking screws

for added fixation.• Distal targeting device for accurate screw placement.• Bolt/claw for reattachment of trochanter.• 45mm resection level only.• Useful in most severe proximal femoral bone loss.• Used in proximal femoral allograft procedures for additional rotational stability.• Stem length 260mm bowed, with sizes 13 – 19mm in 2mm increments.• Utilizes 5.0mm Kaesman screws.

Mallory-Head®

Interlocking CalcarHip System

Mallory-Head® and PPS™ are trademarks of Biomet, Inc.

Page 36: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Mallory-Head®InterlockingCalcarHipSystem

154781154783154785154787

RightPartNumber13 x 45 x 260mm15 x 45 x 260mm17 x 45 x 260mm19 x 45 x 260mm

Description

154780154782154784154786

LeftPartNumber

Page 37: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• Porous coated on proximal 1/3, with distal 2/3 Interlok® finish over

anti-rotational grooves.• Features the same proximal finned geometry as the primary porous implants.• Lengths of 250 and 300mm bowed stems—needed lengths required to bridge

distal cortical defects and provide increased stability and fixation.• Used in revisions where there is minor reconstruction to be done proximally

with intact calcar and very little osteolysis.• Mallory-Head® instrumentation.

Mallory-Head®

Long StemHip System

The Mallory-Head® Revision Hip System is marketed for use with bone cement in the United States.Mallory-Head® and Interlok® are registered trademarks of Biomet, Inc.

Page 38: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Mallory-Head®LongStemHipSystem

104810104812104814104816104818

104910104912104914104916104918

104809104811104813104815104817

104909104911104913104915104917

RightPartNumber LeftPartNumber9 x 250mm11 x 250mm13 x 250mm15 x 250mm17 x 250mm

9 x 300mm11 x 300mm13 x 300mm15 x 300mm17 x 300mm

Description

Page 39: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Trochanteric bolts/claws/plates provide additional stability.• HA option over PPS™ coating.• Used for large defects in the calcar region with severe bone loss.• Modularity allows customization via Morse taper and segmental locking

screw attachment.• Offers 34, 45 and 55mm resection levels (A through E bodies) to

compensate for bone loss in the proximal/medial portion of the femur.• Version adjustment capability with Sundial.• Roller-hardened technology provides 50% stronger taper than

competitive tapers.1

Mallory-Head®

Modular CalcarProximals

1 Data on file at Biomet.Mallory-Head® and PPS™ are trademarks of Biomet, Inc.

Page 40: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Mallory-Head®ModularCalcarProximals

21-10811021-10811221-10811521-10811721-10811921-10813021-10813221-10813521-10813721-10813921-10815021-10815221-10815521-10815721-108159

––

HAPartNumber34A34B34C34D34E45A45B45C45D45E55A55B55C55D55E65A75A

Size

Mallory-Head®ModularMetaphysealSegment

108110108112108115108117108119108130108132108135108137108139108150108152108155108157108159108710108730

PartNumber

11-10502011-105021

MediumLarge

PartNumber CoCrTrochantericClaw

11-10491111-10491411-10491211-10491511-104913

40 – 50mm45 – 55mm50 – 60mm55 – 65mm60 – 70mm

TrochBolt/PlatesPartNo. Description11-10500511-10500611-10500711-10500811-105009

LatClawConnectorPartNo.

13-104756

TrochanterBoltw/PolyPlugOblong(ModCalcar)

Page 41: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Used for large defects in the calcar region with severe bone loss.• Modularity allows customization via Morse taper and segmental locking

screw attachment.• Several distal lengths available to bridge distal defects (75 – 300mm).• Coronal slot to reduce thigh pain. Impact® distal stems may be utilized

with the system.• HA option over PPS™ coating (220mm and 250mm options only).• Roller-hardened technology provides 50% stronger taper than

competitive tapers.1

• Various plasma spray porous coating levels available: 220mm (40% to 80%), 250mm (80%), and 300mm (60%).

• Version adjustment capability with Sundial.• Macro sizes up to 23mm and stem lengths of 350mm.

Mallory-Head®

Modular CalcarDistals

1 Data on file at Biomet.Mallory-Head® , Impact® and PPS™ are trademarks of Biomet, Inc.

Page 42: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Mallory-Head®ModularCalcarDistals

11-10845111-10845311-10845511-10845711-10845911-10825111-10825311-10825511-10825711-108259

–––––

220mmPartNumber

11mm13mm15mm17mm19mm11mm13mm15mm17mm19mm11mm13mm15mm17mm19mm

Size

Mallory-Head®ModularDiaphysealSegmentsw/LockingScrew

40% Porous40% Porous40% Porous40% Porous40% Porous80% Porous80% Porous80% Porous80% Porous80% Porous60% Porous60% Porous60% Porous60% Porous60% Porous

%Porous

–––––

11-10827111-10827311-10827511-10827711-108279

–––––

250mmPartNumber

––––––––––

11-10809111-10809311-10809511-10809711-108099

300mmPartNumber

–––––

21-10825121-10825321-10825521-10825721-108259

–––––

HA220mmPartNumber

–––––

21-10827121-10827321-10827521-10827721-108279

–––––

HA250mmPartNumber

11-10874011-10874111-10874211-10874311-10874411-10874511-108746

200mmPartNumber

14mm15mm16mm17mm18mm19mm20mm

Size

STS™DiaphysealSegments

11-10875011-10875111-10875211-10875311-10875411-10875511-108756

240mmPartNumber

11-13516011-13516111-13516211-13516311-13516411-13516511-13516611-13516711-13516811-13516911-135170

StraightPartNumber

11mm12mm13mm14mm15mm16mm17mm18mm19mm20mm21mm

Size

165mmDiaphysealSegments100%Coated

112000

SpiralockSegmentalLockingScrew

Page 43: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• PPS™ coated on proximal 40% of stem.• Porous coated keel allows transfer of rotational load to the calcar region.• Has 2mm wire passage holes for reattachment of trochanter.• Can use with trochanteric bolts/plates/claws.• 34, 45 and 55mm resection levels offered.• Lengths include 170 (straight) and 220/260mm (bowed).• The long stems have a distal anterior bow to provide better stability and

more closely match the femur.• 99.2% survivorship up to 13 years follow-up. Only 1.1% femoral complications

out of 1,179 revision hips (Head, et al.; AAHKS Meeting, 2001).• Used clinically since 1987.

Mallory-Head®

One-Piece CalcarHip System

The Mallory-Head® Calcar Hip System is marketed for use with bone cement in the United States.Mallory-Head® and PPS™ are trademarks of Biomet, Inc.

Page 44: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Mallory-Head®One-PieceCalcarHipSystem

11-10494711-10494911-10495111-10495311-10495511-104977

11-10495711-10496111-10496511-10496911-10497311-104984

11-10495911-10496311-10496711-10497111-10497511-104986

11-10494811-10495011-10495211-10495411-10495611-104978

11-10495811-10496211-10496611-10497011-10497411-104985

11-10496011-10496411-10496811-10497211-10497611-104987

RightPartNumber LeftPartNumber9 x 220mm11 x 220mm13 x 220mm15 x 220mm17 x 220mm19 x 220mm9 x 220mm11 x 220mm13 x 220mm15 x 220mm17 x 220mm19 x 220mm9 x 220mm11 x 220mm13 x 220mm15 x 220mm17 x 220mm19 x 220mm

Description34mm34mm34mm34mm34mm34mm45mm45mm45mm45mm45mm45mm55mm55mm55mm55mm55mm55mm

ResectionLevel

11-10490211-10490311-10490411-104905

34mm34mm34mm34mm

PartNumber ResectionLevel9 x 170mm11 x 170mm13 x 170mm15 x 170mm

StraightStem

11-10491111-10491411-10491211-10491511-104913

TrochBolt/PlatesPartNo.40 – 50mm45 – 55mm50 – 60mm55 – 65mm60 – 70mm

Description11-10500511-10500611-10500711-10500811-105009

11-10502011-105021

PartNumberMediumLarge

CoCrTrochantericClaws

11-104910

TrochanterBoltw/PolyPlugRound

Lat.ClawConnectorPartNo.

Page 45: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• Titanium PPS™ coating for enhanced bone ingrowth.• 135˚ neck angle.• Bi-planar taper geometry.• Collar and collarless proximal body.• Modular system allows precise fit and fill.• Six proximal body sizes.• Fully interchangeable with Modular Calcar System (used with all Mallory-Head®

modular distal stems including STS distals).• HA option over porous plasma spray.

Modular Reach®

RevisionHip System

Mallory-Head® , Reach® and PPS™ are trademarks of Biomet, Inc.

Page 46: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

ModularReach®RevisionHipSystem

108391108393108395108397108399108401

108291108293108295108297108299108301

CollaredPartNumber CollarlessPartNumberProximal Size 1Proximal Size 2Proximal Size 3Proximal Size 4Proximal Size 5Proximal Size 6

Description

21-10839121-10839321-10839521-10839721-108399

21-10829121-10829321-10829521-10829721-108299

HACollaredPartNumber HACollarlessPartNumberProximal Size 1Proximal Size 2Proximal Size 3Proximal Size 4Proximal Size 5

Description

Page 47: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• Unique spline geometry reduces stem stiffness and risk of subsidence.• Anatomic neck angle 135˚ for added offset.• One piece 270mm straight tapered stem from neck resection.• Lateral holes for soft tissue reattachment.• 1.5˚ taper extends the stemʼs entire length.• Spline depth 1.5mm – 2.5mm provides rotational stability.• 30 grit-blast surface finish for bone ingrowth.• Simple, precise instruments and trials.

PLR™ SplinedHip System

PLR™ is a trademark of Biomet, Inc.

Page 48: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

PLR™SplinedHipSystem

11-15831411-15831511-15831611-15831711-15831811-15831911-15832011-15832111-15832211-15832311-158324

14 x 270mm15 x 270mm16 x 270mm17 x 270mm18 x 270mm19 x 270mm20 x 270mm21 x 270mm22 x 270mm23 x 270mm24 x 270mm

PartNumber Description

Page 49: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Forged Ti alloy.• Stem fully coated—100% PPS™ coating.• 3˚ bi-planar taper proximally to promote compressive loading, cylindrical

after 100mm.• Neck extended 6mm to help restore offset.• Duckbill collar stresses the medial calcar and helps prevent subsidence

of the stem.• Stem size includes distal porous coating—Example: 13mm stem size =

13mm distal diameter with porous coating.• Stem lengths: 200mm straight, 200mm bowed and 250mm bowed.• Ream = 0.5mm – 1mm overream distal.

Reach®

RevisionHip System

Reach® and PPS™ are trademarks of Biomet, Inc.

Page 50: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Reach®RevisionHipSystem

12-16211112-16211312-16211512-16211712-162119

PartNumber11 x 200mm13 x 200mm15 x 200mm17 x 200mm19 x 200mm

Description

Reach®200mmStraight100%Coated

162111162113162115162117162119

162112162114162116162118162120

RightPartNumber LeftPartNumber11 x 200mm13 x 200mm15 x 200mm17 x 200mm19 x 200mm

Description

Reach®200mmBowed100%Coated

11-16211111-16211311-16211511-16211711-162119

11-16211211-16211411-16211611-16211811-162120

RightPartNumber LeftPartNumber11 x 200mm13 x 200mm15 x 200mm17 x 200mm19 x 200mm

Description

Reach®250mmBowed100%Coated

Page 51: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

DesignFeatures:• Cobalt chrome.• Proximal 40% Interlok® finish, smooth distally.• 3˚ bi-planar taper proximally to promote compressive loading—cylindrical

after 100mm.• Duckbill collar stresses the medial calcar and helps prevent subsidence of the stem.• Lateral wire holes provide for reattachment of the trochanter.• Available in 200 and 250mm lengths (bowed).• Alliance® instrumentation.

Rx 90™

RevisionHip System

The Rx 90™ Revision Hip System is marketed for use with bone cement in the United States.Rx 90™, Interlok® and Alliance® are trademarks of Biomet, Inc.

Page 52: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Rx90™RevisionHipSystem

129113129115129117129119

129123129125129127129129

129114129116129118129120

129124129126129128129130

RightPartNumber LeftPartNumber13 x 200mm15 x 200mm17 x 200mm19 x 200mm

13 x 250mm15 x 250mm17 x 250mm19 x 250mm

Description

Page 53: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Stanmore™ Hip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Smooth satin finish (17 Ra).• Unchanged design with over 30 years of clinical use.• Small collar for cement pressurization.• 130˚ neck angle.• Available in standard (increased offset = 8 – 9mm) and straight options.• Slot in top of trunion allows for rotational control during insertion.• Simple starter ream and fully toothed broach surgical technique.• 92% survivorship at 22 years (Deutman, JBJS 2000).

The Stanmore™ Hip System is marketed for use with bone cement in the United States.Stanmore™ is a trademark of Biomet, Inc.

Page 54: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Stanmore™HipSystem

12-16424112-16424212-16424312-16424412-164245

Size 1Size 2Size 3Size 4Size 5

StandardStemPartNumber

Size

8 x 123mm10 x 132mm12 x 140mm14 x 149mm16 x 158mm

Description

12-16425112-16425212-16425312-16425412-164255

StraightStemPartNumber

164236164237164238164239164240

Size 1Size 2Size 3Size 4Size 5

PartNumber Description

Stanmore™PMMADistalStemPositioners

Page 55: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]

Form No. Y-BMT-812/051503/H

Taperloc®

Hip SystemDesignFeatures:• Forged Ti alloy.• Proximal 50% PPS™ coated.• Neck angle 138.̊• Available in a lateralized version—post is shifted 7.6mm medially so leg

length is not affected, but tissues will be tightened.• Flat tapered stem.• HA option over porous plasma spray.• Reduced distal option (Exact™ reduced distal rasps/provisionals are recommended).• Simple starter reamer and fully toothed broach surgical technique.• 99.6% survivorship at 12 year follow-up out of 4,750 patients

(Rothman; Crucial Decisions in TJR and Sports Medicine, Bermuda, 1998).The Taperloc® Hip System is marketed for non-cemented use in skeletally mature patients undergoing primary hip replacement surgery as a result of noninflammatory degenerative joint disease.Taperloc® and PPS™ are trademarks of Biomet, Inc.

Page 56: Table of Contents - · PDF fileBi-Metric ® Head/Neck Hip System. 12-162380 12-162381 12-162382 12-162383 12-162384 12-162385 12-162386 12-162387 12-162388 9 x 34 x 150mm 11 x 34 x

Taperloc®HipSystem

21-10320221-10320321-10320421-10320521-10320621-10320721-10320821-10320921-10321021-10321121-103212

21-12320221-12320321-12320421-12320521-12320621-12320721-12320821-12320921-12321021-12321121-123212

PartNumber LateralizedPartNumber7.5 x 135mm9.0 x 137mm

10.0 x 140mm11.0 x 142mm12.5 x 145mm13.5 x 147mm15.0 x 150mm17.5 x 155mm20.0 x 160mm22.5 x 165mm25.0 x 170mm

Description

HATaperloc®Hip

12-10320612-10320712-10320812-10320912-10321012-10321112-103212

13-10320613-10320713-10320813-10320913-10321013-10321113-103212

PartNumber LateralizedPartNumber12.5 x 145mm13.5 x 147mm15.0 x 150mm17.5 x 155mm20.0 x 160mm22.5 x 165mm25.0 x 170mm

Description

ReducedDistalTaperloc®Hip

103202103203103204103205103206103207103208103209103210103211103212

11-10320211-10320311-10320411-10320511-10320611-10320711-10320811-10320911-10321011-10321111-103212

PartNumber LateralizedPartNumber7.5 x 135mm9.0 x 137mm

10.0 x 140mm11.0 x 142mm12.5 x 145mm13.5 x 147mm15.0 x 150mm17.5 x 155mm20.0 x 160mm22.5 x 165mm25.0 x 170mm

Description

ModularPorousTaperloc®Hip