table of contents - · pdf filebi-metric ® head/neck hip system. 12-162380 12-162381...
TRANSCRIPT
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Alliance® Hip System
Balance® Hip System
Bio-Moore® II Hip System
Mallory-Head® Hip System
Revision Hip System
Stanmore™ Hip System
Taperloc® Hip System
Table of Contents
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Answer®
Hip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Interlok® finish enhances cement-to-implant bonding.• 3˚ bi-planar taper to promote compressive loading vs. shear of the cement mantle.• Integrated A/P spacers to centralize proximally to allow for uniform cement mantle.• PMMA distal centralizer to guard against varus or valgus positioning.• Lateralized option— Morse taper is shifted 6mm medially without altering
leg length.• Duckbill collar stresses the medial calcar and helps prevent subsidence of the stem.• Reduced medial aspect allows for a 3.5mm proximal/medial cement mantle.• Alliance® instrumentation.
The Answer® Hip System is marketed for use with bone cement in the United States.Answer®, Alliance® and Interlok® are registered trademarks of Biomet, Inc.
Answer®HipSystem
162601162602162603162604162605
9 x 125mm11 x 135mm13 x 145mm15 x 155mm17 x 165mm
PartNumber Description
Answer®FemoralComponents
162501162502162503162504162505
LateralizedPartNumber
162656162640162657162641162658162642162659162643162660162644162661162646
9mm10mm11mm12mm13mm14mm15mm16mm17mm18mm19mm20mm
PartNumber Description
Answer®DistalStemPositioners
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Bi-Metric® Head/NeckHip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Interlok® finish enhances cement-to-implant bonding.• 3˚ bi-planar taper to promote compressive loading vs. shear of the cement mantle.• Lateral flange holes for reattachment of trochanter.• PMMA distal centralizer guards against varus or valgus positioning.• Medial keel for rotational stability.• 34, 45, 55mm resection levels—9, 11, 13 and 15mm diameters.• 150mm, 200mm and 250mm lengths.• Alliance® instrumentation.
The Bi-Metric® Head/Neck Hip System is marketed for use with bone cement in the United States.Bi-Metric®, Interlok® and Alliance® are registered trademarks of Biomet, Inc.
Bi-Metric®Head/NeckHipSystem
12-16238012-16238112-16238212-16238312-16238412-16238512-16238612-16238712-162388
9 x 34 x 150mm11 x 34 x 150mm13 x 34 x 150mm9 x 45 x 150mm11 x 45 x 150mm13 x 45 x 150mm9 x 55 x 150mm11 x 55 x 150mm13 x 55 x 150mm
150mmPartNumber Description
162907162909162911162913162915162917
7mm9mm11mm13mm15mm17mm
PartNumber Description
PMMACenteringSleeves
12-16258012-16258212-16258412-16257412-16258612-16258812-16259012-16257612-16259212-16259412-16259612-162578
9 x 34 x 250mm11 x 34 x 250mm13 x 34 x 250mm15 x 34 x 250mm9 x 45 x 250mm11 x 45 x 250mm13 x 45 x 250mm15 x 45 x 250mm9 x 55 x 250mm11 x 55 x 250mm13 x 55 x 250mm15 x 55 x 250mm
250mmLeftPartNumber Description12-16258112-16258312-16258512-16257512-16258712-16258912-16259112-16257712-16259312-16259512-16259712-162579
250mmRightPartNumber
12-16248012-16248112-16248212-16248912-16248312-16248412-16248512-16249012-16248612-16248712-16248812-162491
9 x 34 x 200mm11 x 34 x 200mm13 x 34 x 200mm15 x 34 x 200mm9 x 45 x 200mm11 x 45 x 200mm13 x 45 x 200mm15 x 45 x 200mm9 x 55 x 200mm11 x 55 x 200mm13 x 55 x 200mm15 x 55 x 200mm
200mmPartNumber Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Net-forged Ti alloy provides precise and consistent development of hip implants
and related instrumentation.• Proximal 1/3 PPS™ coated.• 3˚ bi-planar taper.• Collared in standard offset with neck angle of 140.̊ Non-collared in standard
offset with neck angle of 135˚ and 130˚ for lateralized option.• Offset option increases proportionally based on stem size (5 – 9mm of
additional offset).• Medialized insertion hole.• HA option over porous plasma spray.• Use only with Exact™ Alliance® Instrumentation.
Bi-Metric® X-Series Porous Primary Hip System
Bi-Metric®, Alliance®, Exact™ and PPS™ are trademarks of Biomet, Inc.
Bi-Metric®X-SeriesPorousPrimaryHipSystem
X21-180307X21-180308X21-180309X21-180310X21-180311X21-180312X21-180313X21-180314X21-180315X21-180316X21-180317X21-180318X21-180319X21-180320X21-180321
–X21-182308X21-182309X21-182310X21-182311X21-182312X21-182313X21-182314X21-182315X21-182316X21-182317X21-182318X21-182319X21-182320X21-182321
HA*StandardPartNumber HA*LateralizedPartNumber7mm8mm9mm
10mm11mm12mm13mm14mm15mm16mm17mm18mm19mm20mm21mm
Description
X180307X180308X180309X180310X180311X180312X180313X180314X180315X180316X180317X180318X180319X180320X180321
–X11-180308X11-180309X11-180310X11-180311X11-180312X11-180313X11-180314X11-180315X11-180316X11-180317X11-180318X11-180319X11-180320X11-180321
Non-CollaredPartNo. CollarlessLat.PartNo.7 x 115mm8 x 120mm9 x 125mm
10 x 130mm11 x 135mm12 x 140mm13 x 145mm14 x 150mm15 x 155mm16 x 160mm17 x 165mm18 x 170mm19 x 175mm20 x 180mm21 x 185mm
DescriptionCollaredPartNo.
X181307X181308X181309X181310X181311X181312X181313X181314X181315X181316X181317X181318X181319X181320X181321
* HA offered in collarless option only.
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• Interlok® finish enhances cement-to-implant bonding.• Proximal 1/3 HA coated (Hydroxyapatite)—promotes bony ingrowth in the HA
coated grooved surface.• 3˚ bi-planar taper.• 50 micron coating of HA.• Large “V” shaped grooves on proximal 1/3 promotes bony interdigitation.• Collarless.• Alliance® instrumentation.
Bio-Groove®
HAHip System
Bio-Groove®, Interlok® and Alliance® are registered trademarks of Biomet, Inc.
Bio-Groove®HAHipSystem
11-16280711-16280811-16280911-16281011-16281111-16281211-16281311-16281411-16281511-16281611-16281711-16281811-162819
7 x 115mm8 x 120mm9 x 125mm
10 x 130mm11 x 135mm12 x 140mm13 x 145mm14 x 150mm15 x 155mm16 x 160mm17 x 165mm18 x 170mm19 x 175mm
PartNumber Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Hip FractureHip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Interlok® finish enhances cement-to-implant bonding.• 3˚ bi-planar taper to promote compressive loading vs. shear of the cement mantle.• Duckbill collar stresses medial calcar and helps prevent subsidence.• 140˚ neck angle.• Can be cemented or press-fit.• If press-fitting, special gold-nitrided Hip Fracture broaches must be used.• Sizing is one-to-one. Example: If you template to a 10, ream and broach to a 10.
If you are cementing, implant an 8mm stem. If you are press-fitting, implant a 10mm stem.
• PMMA centering sleeve centralizes stem within the canal.• Alliance® instrumentation.Interlok® and Alliance® are registered trademarks of Biomet, Inc.
HipFractureHipSystem
162900162901162902162903162904
–
8mm10mm12mm14mm16mm18mm
PartNumber Description
HipFractureFemoralComponents
31-47390031-47390131-47390231-47390331-47390431-473905
BroachPartNumber
162908162910162912162914162916
–
PMMACenteringSleeve
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged cobalt chrome— approximately twice the fatigue strength of cast CoCr.• Interlok® finish enhances cement-to-implant bonding.• 3˚ bi-planar taper to promote compressive loading vs. cylindrical designs.• Integrated A/P and medial spacers allow for centralized placement and an even
cement mantle.• Cobra flare for cement pressurization.• Duckbill collar stresses medial calcar and helps prevent subsidence of stem.• PMMA distal centralizer for more consistent cement mantle.• Alliance® instrumentation.• 99.3% survivorship at mean follow-up of 7 years (Bankston; Total Joint
and Sports Medicine Symposium, 2001).*Also offered in a lateralized version where the Morse taper is shifted 6mm medially. When using the lateralized option, the offset is increased, thereby tightening soft tissues without affecting leg length.
Integral®
Centralizer*Hip System
Integral®, Interlok® and Alliance® are registered trademarks of Biomet, Inc.
Integral®CentralizerHipSystem
12-16260912-16261112-16261312-16261512-162617
9 x 125mm11 x 135mm13 x 145mm15 x 155mm17 x 165mm
PartNumber Description
Integral®FemoralComponents
11-16270911-16271111-16271311-16271511-162717
LateralizedPartNumber
162656162640162657162641162658162642162659162643162660162644162661162646
9mm10mm11mm12mm13mm14mm15mm16mm17mm18mm19mm20mm
PartNumber Description
DistalStemPositioners
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Net-forged Ti alloy provides precise and consistent development of hip implants
and related instrumentation.• Extended level of PPS™ coating (tuxedo tail) creates a tight circumferential
“scratch-fit” that provides initial stability.• 3˚ bi-planar taper.• 140˚ neck angle (both standard and lateralized).• Broad lateral shoulder for rotational stability to promote compressive loading.• Porous coated duckbill collar stresses the medial calcar and helps prevent
subsidence of the stem.• Also offered in a reduced proximal profile (RPP) option to fit the “stove pipe”
femur. Exact™ RPP broaches (nitrided black) must be used.• Use only with Exact™ Alliance® Instrumentation.
Integral®
X-Series Porous PrimaryHip System
Integral, Alliance®, Exact™ and PPS™ are trademarks of Biomet, Inc.
Integral®X-SeriesPorousPrimaryHipSystem
X170307X170308X170309X170310X170311X170312X170313X170314X170315X170316X170317X170318X170319X170320X170321
–X11-170308X11-170309X11-170310X11-170311X11-170312X11-170313X11-170314X11-170315X11-170316X11-170317X11-170318X11-170319X11-170320X11-170321
PartNumber LateralizedPartNumber7 x 115mm8 x 120mm9 x 125mm
10 x 130mm11 x 135mm12 x 140mm13 x 145mm14 x 150mm15 x 155mm16 x 160mm17 x 165mm18 x 170mm19 x 175mm20 x 180mm21 x 185mm
Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Osteocap rs®
Hip SystemDesignFeatures:• Forged Ti alloy.• Circumferential PPS™ coating on proximal 1/3 and under conical collar.• 30˚ proximal geometry for optimum physiological stress transfer coupled with
a 3˚ bi-planar taper.• Distal coronal slot to reduce stem stiffness and minimize distal point loading.• Four distal flutes enhance rotational stability.• 135˚ neck angle.• rs (Reduced Stiffness).• Alliance® instrumentation.• Must use cylindrical reamers, conical reamers, necks and reduced proximal
profile (RPP) broaches.The Osteocap rs® Hip System is marketed for noncemented use in skeletally mature patients undergoing primary hip replacement surgery as a result of noninflammatory degenerative joint disease.Osteocap rs®, Alliance® and PPS™ are trademarks of Biomet, Inc.
Osteocaprs®HipSystem
110109110110110111110112110113110114110115110117
31-11010931-11011031-11011131-11011231-11011331-11011431-11011531-110117
PartNumber ProvisionalNumber9 x 145mm
10 x 150mm11 x 150mm12 x 155mm13 x 155mm14 x 160mm15 x 160mm17 x 165mm
Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• Proximal 40% circumferential PPS™ coating, while remainder of stem
is polished.• Bi-planar taper proximal 2/3 of implant. Cylindrical distally with multiple distal
splines providing increased rotational stability.• 130˚ neck angle.• 10˚ anteverted neck to aid in replicating normal anatomies.• Duckbill collar with porous coating on the bottom of the collar.• Distal coronal slot on sizes 11 and above.• Alliance® instrumentation with combination reamers.
Progressive™ Hip System
Progressive™, Alliance® and PPS™ are trademarks of Biomet, Inc.
Progressive™HipSystem
166314166316166318166320166322166324166326166328166330
9 x 125mm10 x 130mm11 x 135mm12 x 140mm13 x 145mm14 x 150mm15 x 155mm16 x 160mm17 x 165mm
RightPartNumber Description
166315166317166319166321166323166325166327166329166331
LeftPartNumber
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Rx 90™ Smooth Hip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Smooth satin finish (17 Ra).• 3˚ bi-planar taper to promote compressive loading vs. shear of the cement mantle.• Reduced medial collar provides optimal calcar support.• Integrated PMMA proximal spacers located on the medial, anterior
and posterior aspects.• Large cement mantle—3.5mm proximal medially, 2.5mm proximal laterally.• PMMA distal centralizers are available in 1.5mm (standard) or 2.5mm (large) sizes.• 140˚ neck angle. Available in lateralized option—Morse taper is shifted 6mm
medially without altering leg length.• Alliance® instrumentation.
The Rx 90™ Primary Hip System is marketed for use with bone cement in the United States.Rx 90™and Alliance® are trademarks of Biomet, Inc.
Rx90™SmoothHipSystem
149019149021149023149025149027
9mm11mm13mm15mm17mm
1.5mmPartNumber Description
Rx90™SmoothCementSpacers
149029149031149033149035149037
2.5mmPartNumber
11-15900911-15901111-15901311-15901511-159017
9 x 125mm11 x 135mm13 x 145mm15 x 155mm17 x 165mm
LateralizedPartNumber Description
Rx90™SmoothFemoralComponents
159009159011159013159015159017
StandardPartNumber
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Balance®
Hip SystemDesignFeatures:• Forged Ti alloy.• Proximal 40% PPS™ coating for enhanced bone ingrowth.• 3˚ bi-planar taper promotes compressive loading.• 5˚ proximal anterior build-up for maximum A/P fill.• 5˚ anteverted neck, right and left specific, aids in replicating normal anatomies.• 135˚ neck angle.• Middle 1/3 Interlok® finish and distal 1/3 is satin finish.• Simple “ream only” surgical technique.
The Balance® Hip System is marketed for non-cemented use in skeletally mature patients undergoing primary hip replacement surgery as a result of noninflammatory degenerative joint disease.Balance®, Interlok® and PPS™ are trademarks of Biomet, Inc.
Balance®HipSystem
Slots in distal portion of implant begin at size 16mm.
170096170097170098170099
31-20004031-20004131-20004231-200043
PartNumber ProvisionalNumber19 x 180mm Rt19 x 180mm Lt20 x 180mm Rt20 x 180mm Lt
Description
180000180001180002180003180004180005180006180007180008180009180010180011180012180013180014180015180016180017180018180019180020180021180022180023
31-20001331-20001431-20001531-20001631-20001731-20001831-20001931-20002031-20002131-20002231-20002331-20002431-20002531-20002631-20002731-20002831-20002931-20003031-20003131-20003231-20003331-20003431-20003531-200036
PartNumber ProvisionalNumber7 x 140mm Rt7 x 140mm Lt8 x 145mm Rt8 x 145mm Lt9 x 150mm Rt9 x 150mm Lt
10 x 155mm Rt10 x 155mm Lt11 x 160mm Rt11 x 160mm Lt12 x 165mm Rt12 x 165mm Lt13 x 170mm Rt13 x 170mm Lt14 x 175mm Rt14 x 175mm Lt15 x 180mm Rt15 x 180mm Lt16 x 180mm Rt16 x 180mm Lt17 x 180mm Rt17 x 180mm Lt18 x 180mm Rt18 x 180mm Lt
Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• Interlok® finish enhances cement-to-implant bonding.• Type I Morse taper.• I-beam design for rotational stability.• Incorporates a lateral fin for rotational stability.• Offered in solid or fenestrated options.• Can press-fit or cement solid components, and can ONLY press-fit
fenestrated components.• Needs taper inserts for use with Endo II heads (5 neck lengths: -6, -3, Std.,
+3, and +6mm).• Compatible with all Biomet® acetabular components.
Bio-Moore®
IIHip System
Bio-Moore®, Interlok® and Biomet® are registered trademarks of Biomet, Inc.
Bio-Moore®IIHipSystem
139202139203139204139205
–139209139210139211
SolidPartNumber FenestratedPartNumber10 x 165mm12 x 165mm14 x 165mm16 x 165mm
Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Mallory-Head® Interlok®
Hip SystemDesignFeatures:• Forged cobalt chrome— approximately twice the fatigue strength of cast CoCr.• Interlok® finish on proximal 1/3 of stem and the distal 2/3 of the stem is smooth.• 3˚ bi-planar taper to promote compressive loading vs. cylindrical designs.• Duckbill collar anchors the implant to the bone and directs the cement to the
distal canal.• Distal I-beam channel resists rotational forces.• Two 20˚ ribs located proximally on the anterior and posterior sides force cement
medially into compression.• PMMA centering sleeve used distally for central alignment in the canal.• Mallory-Head® cemented instrumentation.
The Mallory-Head® Interlok® Hip System is marketed for use with bone cement in the United States.Mallory-Head® and Interlok® are registered trademarks of Biomet, Inc.
Mallory-Head®Interlok®HipSystem
105606105607105609105611105613105615
PartNumber5/7 x 135mm7 x 140mm9 x 150mm11 x 160mm13 x 170mm15 x 180mm
Description
162907162909162911162913162915
PartNumber7mm9mm11mm13mm15mm
PMMACenteringSleeve
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Mallory-Head® Porous PrimaryHip SystemDesignFeatures:• Forged Ti alloy.• PPS™ (Porous Plasma Spray) coating on proximal 1/3 of stem, middle 1/3 of stem is
roughened Interlok® finish, and distal 1/3 is smooth finish.• Dual tapered geometry provides a lateral to medial taper and a 3˚ included taper
from proximal to distal.• Proximal finned geometry—designed to minimize rotation due to torsional loads.• Standard—136˚ neck angle; lateralized—131˚ neck angle. Offset option increases
proportionately based on stem size (6 – 8mm of additional offset).• Provides quadrilateral fixation via: Lateral fin, anterior fin, posterior fin, and
medial contact.• HA option over PPS™ coating.• 99.5% survivorship at 11 years (Head, et al.; Orthopedics, 1999).Mallory-Head® , Interlok® and PPS™ are trademarks of Biomet, Inc.
Mallory-Head®PorousPrimaryHipSystem
9 x 150mm10 x 155mm11 x 160mm12 x 165mm13 x 170mm14 x 175mm15 x 180mm16 x 180mm17 x 180mm
11-10420911-10421011-10421111-10421211-10421311-10421411-10421511-10421611-104217
PartNumber Description
Mallory-Head®LateralizedPorousPrimary
11-10410611-10410711-10410811-10410911-10411011-10411111-10411211-10411311-10411411-10411511-10411621-10411721-10411821-104119
6 x 135mm7 x 140mm8 x 145mm9 x 150mm
10 x 155mm11 x 160mm12 x 165mm13 x 170mm14 x 175mm15 x 180mm16 x 180mm17 x 180mm18 x 180mm19 x 180mm
PartNumber Description
Mallory-Head®PorousPrimary
–––
21-10410921-10411021-10411121-10411221-10411321-10411421-10411521-10411621-10411721-10411821-104119
HAPartNumber
21-12430921-12431021-12431121-12431221-12431321-12431421-12431521-12431621-124317
HAPartNumber
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• Proximal 1/3 of stem PPS™ coated, Interlok® finish distally for enhanced stability.• Collar design with 2˚ anterior bow.• Available in 200mm, 250mm and 300mm lengths (all bowed).• Alliance® instrumentation.
Bi-Metric®
Long StemHip System
The Bi-Metric® Revision Hip System is marketed for use with bone cement in the United States.Bi-Metric®, Interlok®, Alliance® and PPS™ are trademarks of Biomet, Inc.
Bi-Metric®LongStemHipSystem
162340162342162344162346162348
162350162352162354162356162358
162360162362162364162366162368
162341162343162345162347162349
162351162353162355162357162359
162361162363162365162367162369
PartNumberRight PartNumberLeft9 x 200mm11 x 200mm13 x 200mm15 x 200mm17 x 200mm
9 x 250mm11 x 250mm13 x 250mm15 x 250mm17 x 250mm
9 x 300mm11 x 300mm13 x 300mm15 x 300mm17 x 300mm
Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• 70% PPS™ coated.• 3˚ bi-planar taper proximally to promote compressive loading, cylindrical
after 100mm.• Distal coronal slot to reduce thigh pain.• Porous coated duckbill collar stresses the calcar and prevents subsidence.• 140˚ neck angle.• Can be used as a primary or a short revision stem.• Also offered in a reduced proximal profile (RPP) option to fit the “stove pipe” femur (RPP broaches must be used).• Alliance® instrumentation.
Integral®
180Hip System
Integral® , Alliance® and PPS™ are trademarks of Biomet, Inc.
Integral®180HipSystem
166010166011166012166013166014166015166016166017166018166019
–11-16601111-16601211-16601311-16601411-16601511-16601611-16601711-16601811-166019
PartNumber ReducedProximalProfilePartNumber10 x 180mm11 x 180mm12 x 180mm13 x 180mm14 x 180mm15 x 180mm16 x 180mm17 x 180mm18 x 180mm19 x 180mm
Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• Titanium PPS™ coating proximal 40% of stem for enhanced
bone ingrowth.• Proximal calcar loading implant with distal interlocking screws
for added fixation.• Distal targeting device for accurate screw placement.• Bolt/claw for reattachment of trochanter.• 45mm resection level only.• Useful in most severe proximal femoral bone loss.• Used in proximal femoral allograft procedures for additional rotational stability.• Stem length 260mm bowed, with sizes 13 – 19mm in 2mm increments.• Utilizes 5.0mm Kaesman screws.
Mallory-Head®
Interlocking CalcarHip System
Mallory-Head® and PPS™ are trademarks of Biomet, Inc.
Mallory-Head®InterlockingCalcarHipSystem
154781154783154785154787
RightPartNumber13 x 45 x 260mm15 x 45 x 260mm17 x 45 x 260mm19 x 45 x 260mm
Description
154780154782154784154786
LeftPartNumber
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• Porous coated on proximal 1/3, with distal 2/3 Interlok® finish over
anti-rotational grooves.• Features the same proximal finned geometry as the primary porous implants.• Lengths of 250 and 300mm bowed stems—needed lengths required to bridge
distal cortical defects and provide increased stability and fixation.• Used in revisions where there is minor reconstruction to be done proximally
with intact calcar and very little osteolysis.• Mallory-Head® instrumentation.
Mallory-Head®
Long StemHip System
The Mallory-Head® Revision Hip System is marketed for use with bone cement in the United States.Mallory-Head® and Interlok® are registered trademarks of Biomet, Inc.
Mallory-Head®LongStemHipSystem
104810104812104814104816104818
104910104912104914104916104918
104809104811104813104815104817
104909104911104913104915104917
RightPartNumber LeftPartNumber9 x 250mm11 x 250mm13 x 250mm15 x 250mm17 x 250mm
9 x 300mm11 x 300mm13 x 300mm15 x 300mm17 x 300mm
Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Trochanteric bolts/claws/plates provide additional stability.• HA option over PPS™ coating.• Used for large defects in the calcar region with severe bone loss.• Modularity allows customization via Morse taper and segmental locking
screw attachment.• Offers 34, 45 and 55mm resection levels (A through E bodies) to
compensate for bone loss in the proximal/medial portion of the femur.• Version adjustment capability with Sundial.• Roller-hardened technology provides 50% stronger taper than
competitive tapers.1
Mallory-Head®
Modular CalcarProximals
1 Data on file at Biomet.Mallory-Head® and PPS™ are trademarks of Biomet, Inc.
Mallory-Head®ModularCalcarProximals
21-10811021-10811221-10811521-10811721-10811921-10813021-10813221-10813521-10813721-10813921-10815021-10815221-10815521-10815721-108159
––
HAPartNumber34A34B34C34D34E45A45B45C45D45E55A55B55C55D55E65A75A
Size
Mallory-Head®ModularMetaphysealSegment
108110108112108115108117108119108130108132108135108137108139108150108152108155108157108159108710108730
PartNumber
11-10502011-105021
MediumLarge
PartNumber CoCrTrochantericClaw
11-10491111-10491411-10491211-10491511-104913
40 – 50mm45 – 55mm50 – 60mm55 – 65mm60 – 70mm
TrochBolt/PlatesPartNo. Description11-10500511-10500611-10500711-10500811-105009
LatClawConnectorPartNo.
13-104756
TrochanterBoltw/PolyPlugOblong(ModCalcar)
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Used for large defects in the calcar region with severe bone loss.• Modularity allows customization via Morse taper and segmental locking
screw attachment.• Several distal lengths available to bridge distal defects (75 – 300mm).• Coronal slot to reduce thigh pain. Impact® distal stems may be utilized
with the system.• HA option over PPS™ coating (220mm and 250mm options only).• Roller-hardened technology provides 50% stronger taper than
competitive tapers.1
• Various plasma spray porous coating levels available: 220mm (40% to 80%), 250mm (80%), and 300mm (60%).
• Version adjustment capability with Sundial.• Macro sizes up to 23mm and stem lengths of 350mm.
Mallory-Head®
Modular CalcarDistals
1 Data on file at Biomet.Mallory-Head® , Impact® and PPS™ are trademarks of Biomet, Inc.
Mallory-Head®ModularCalcarDistals
11-10845111-10845311-10845511-10845711-10845911-10825111-10825311-10825511-10825711-108259
–––––
220mmPartNumber
11mm13mm15mm17mm19mm11mm13mm15mm17mm19mm11mm13mm15mm17mm19mm
Size
Mallory-Head®ModularDiaphysealSegmentsw/LockingScrew
40% Porous40% Porous40% Porous40% Porous40% Porous80% Porous80% Porous80% Porous80% Porous80% Porous60% Porous60% Porous60% Porous60% Porous60% Porous
%Porous
–––––
11-10827111-10827311-10827511-10827711-108279
–––––
250mmPartNumber
––––––––––
11-10809111-10809311-10809511-10809711-108099
300mmPartNumber
–––––
21-10825121-10825321-10825521-10825721-108259
–––––
HA220mmPartNumber
–––––
21-10827121-10827321-10827521-10827721-108279
–––––
HA250mmPartNumber
11-10874011-10874111-10874211-10874311-10874411-10874511-108746
200mmPartNumber
14mm15mm16mm17mm18mm19mm20mm
Size
STS™DiaphysealSegments
11-10875011-10875111-10875211-10875311-10875411-10875511-108756
240mmPartNumber
11-13516011-13516111-13516211-13516311-13516411-13516511-13516611-13516711-13516811-13516911-135170
StraightPartNumber
11mm12mm13mm14mm15mm16mm17mm18mm19mm20mm21mm
Size
165mmDiaphysealSegments100%Coated
112000
SpiralockSegmentalLockingScrew
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• PPS™ coated on proximal 40% of stem.• Porous coated keel allows transfer of rotational load to the calcar region.• Has 2mm wire passage holes for reattachment of trochanter.• Can use with trochanteric bolts/plates/claws.• 34, 45 and 55mm resection levels offered.• Lengths include 170 (straight) and 220/260mm (bowed).• The long stems have a distal anterior bow to provide better stability and
more closely match the femur.• 99.2% survivorship up to 13 years follow-up. Only 1.1% femoral complications
out of 1,179 revision hips (Head, et al.; AAHKS Meeting, 2001).• Used clinically since 1987.
Mallory-Head®
One-Piece CalcarHip System
The Mallory-Head® Calcar Hip System is marketed for use with bone cement in the United States.Mallory-Head® and PPS™ are trademarks of Biomet, Inc.
Mallory-Head®One-PieceCalcarHipSystem
11-10494711-10494911-10495111-10495311-10495511-104977
11-10495711-10496111-10496511-10496911-10497311-104984
11-10495911-10496311-10496711-10497111-10497511-104986
11-10494811-10495011-10495211-10495411-10495611-104978
11-10495811-10496211-10496611-10497011-10497411-104985
11-10496011-10496411-10496811-10497211-10497611-104987
RightPartNumber LeftPartNumber9 x 220mm11 x 220mm13 x 220mm15 x 220mm17 x 220mm19 x 220mm9 x 220mm11 x 220mm13 x 220mm15 x 220mm17 x 220mm19 x 220mm9 x 220mm11 x 220mm13 x 220mm15 x 220mm17 x 220mm19 x 220mm
Description34mm34mm34mm34mm34mm34mm45mm45mm45mm45mm45mm45mm55mm55mm55mm55mm55mm55mm
ResectionLevel
11-10490211-10490311-10490411-104905
34mm34mm34mm34mm
PartNumber ResectionLevel9 x 170mm11 x 170mm13 x 170mm15 x 170mm
StraightStem
11-10491111-10491411-10491211-10491511-104913
TrochBolt/PlatesPartNo.40 – 50mm45 – 55mm50 – 60mm55 – 65mm60 – 70mm
Description11-10500511-10500611-10500711-10500811-105009
11-10502011-105021
PartNumberMediumLarge
CoCrTrochantericClaws
11-104910
TrochanterBoltw/PolyPlugRound
Lat.ClawConnectorPartNo.
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• Titanium PPS™ coating for enhanced bone ingrowth.• 135˚ neck angle.• Bi-planar taper geometry.• Collar and collarless proximal body.• Modular system allows precise fit and fill.• Six proximal body sizes.• Fully interchangeable with Modular Calcar System (used with all Mallory-Head®
modular distal stems including STS distals).• HA option over porous plasma spray.
Modular Reach®
RevisionHip System
Mallory-Head® , Reach® and PPS™ are trademarks of Biomet, Inc.
ModularReach®RevisionHipSystem
108391108393108395108397108399108401
108291108293108295108297108299108301
CollaredPartNumber CollarlessPartNumberProximal Size 1Proximal Size 2Proximal Size 3Proximal Size 4Proximal Size 5Proximal Size 6
Description
21-10839121-10839321-10839521-10839721-108399
21-10829121-10829321-10829521-10829721-108299
HACollaredPartNumber HACollarlessPartNumberProximal Size 1Proximal Size 2Proximal Size 3Proximal Size 4Proximal Size 5
Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• Unique spline geometry reduces stem stiffness and risk of subsidence.• Anatomic neck angle 135˚ for added offset.• One piece 270mm straight tapered stem from neck resection.• Lateral holes for soft tissue reattachment.• 1.5˚ taper extends the stemʼs entire length.• Spline depth 1.5mm – 2.5mm provides rotational stability.• 30 grit-blast surface finish for bone ingrowth.• Simple, precise instruments and trials.
PLR™ SplinedHip System
PLR™ is a trademark of Biomet, Inc.
PLR™SplinedHipSystem
11-15831411-15831511-15831611-15831711-15831811-15831911-15832011-15832111-15832211-15832311-158324
14 x 270mm15 x 270mm16 x 270mm17 x 270mm18 x 270mm19 x 270mm20 x 270mm21 x 270mm22 x 270mm23 x 270mm24 x 270mm
PartNumber Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Forged Ti alloy.• Stem fully coated—100% PPS™ coating.• 3˚ bi-planar taper proximally to promote compressive loading, cylindrical
after 100mm.• Neck extended 6mm to help restore offset.• Duckbill collar stresses the medial calcar and helps prevent subsidence
of the stem.• Stem size includes distal porous coating—Example: 13mm stem size =
13mm distal diameter with porous coating.• Stem lengths: 200mm straight, 200mm bowed and 250mm bowed.• Ream = 0.5mm – 1mm overream distal.
Reach®
RevisionHip System
Reach® and PPS™ are trademarks of Biomet, Inc.
Reach®RevisionHipSystem
12-16211112-16211312-16211512-16211712-162119
PartNumber11 x 200mm13 x 200mm15 x 200mm17 x 200mm19 x 200mm
Description
Reach®200mmStraight100%Coated
162111162113162115162117162119
162112162114162116162118162120
RightPartNumber LeftPartNumber11 x 200mm13 x 200mm15 x 200mm17 x 200mm19 x 200mm
Description
Reach®200mmBowed100%Coated
11-16211111-16211311-16211511-16211711-162119
11-16211211-16211411-16211611-16211811-162120
RightPartNumber LeftPartNumber11 x 200mm13 x 200mm15 x 200mm17 x 200mm19 x 200mm
Description
Reach®250mmBowed100%Coated
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
DesignFeatures:• Cobalt chrome.• Proximal 40% Interlok® finish, smooth distally.• 3˚ bi-planar taper proximally to promote compressive loading—cylindrical
after 100mm.• Duckbill collar stresses the medial calcar and helps prevent subsidence of the stem.• Lateral wire holes provide for reattachment of the trochanter.• Available in 200 and 250mm lengths (bowed).• Alliance® instrumentation.
Rx 90™
RevisionHip System
The Rx 90™ Revision Hip System is marketed for use with bone cement in the United States.Rx 90™, Interlok® and Alliance® are trademarks of Biomet, Inc.
Rx90™RevisionHipSystem
129113129115129117129119
129123129125129127129129
129114129116129118129120
129124129126129128129130
RightPartNumber LeftPartNumber13 x 200mm15 x 200mm17 x 200mm19 x 200mm
13 x 250mm15 x 250mm17 x 250mm19 x 250mm
Description
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Stanmore™ Hip SystemDesignFeatures:• Forged cobalt chrome—approximately twice the fatigue strength of cast CoCr.• Smooth satin finish (17 Ra).• Unchanged design with over 30 years of clinical use.• Small collar for cement pressurization.• 130˚ neck angle.• Available in standard (increased offset = 8 – 9mm) and straight options.• Slot in top of trunion allows for rotational control during insertion.• Simple starter ream and fully toothed broach surgical technique.• 92% survivorship at 22 years (Deutman, JBJS 2000).
The Stanmore™ Hip System is marketed for use with bone cement in the United States.Stanmore™ is a trademark of Biomet, Inc.
Stanmore™HipSystem
12-16424112-16424212-16424312-16424412-164245
Size 1Size 2Size 3Size 4Size 5
StandardStemPartNumber
Size
8 x 123mm10 x 132mm12 x 140mm14 x 149mm16 x 158mm
Description
12-16425112-16425212-16425312-16425412-164255
StraightStemPartNumber
164236164237164238164239164240
Size 1Size 2Size 3Size 4Size 5
PartNumber Description
Stanmore™PMMADistalStemPositioners
P.O. Box 587, Warsaw, IN 46581-0587 • 574.267.6639 • ©2003 Biomet, Inc. All Rights Reservedweb site: www.biomet.com • eMail: [email protected]
Form No. Y-BMT-812/051503/H
Taperloc®
Hip SystemDesignFeatures:• Forged Ti alloy.• Proximal 50% PPS™ coated.• Neck angle 138.̊• Available in a lateralized version—post is shifted 7.6mm medially so leg
length is not affected, but tissues will be tightened.• Flat tapered stem.• HA option over porous plasma spray.• Reduced distal option (Exact™ reduced distal rasps/provisionals are recommended).• Simple starter reamer and fully toothed broach surgical technique.• 99.6% survivorship at 12 year follow-up out of 4,750 patients
(Rothman; Crucial Decisions in TJR and Sports Medicine, Bermuda, 1998).The Taperloc® Hip System is marketed for non-cemented use in skeletally mature patients undergoing primary hip replacement surgery as a result of noninflammatory degenerative joint disease.Taperloc® and PPS™ are trademarks of Biomet, Inc.
Taperloc®HipSystem
21-10320221-10320321-10320421-10320521-10320621-10320721-10320821-10320921-10321021-10321121-103212
21-12320221-12320321-12320421-12320521-12320621-12320721-12320821-12320921-12321021-12321121-123212
PartNumber LateralizedPartNumber7.5 x 135mm9.0 x 137mm
10.0 x 140mm11.0 x 142mm12.5 x 145mm13.5 x 147mm15.0 x 150mm17.5 x 155mm20.0 x 160mm22.5 x 165mm25.0 x 170mm
Description
HATaperloc®Hip
12-10320612-10320712-10320812-10320912-10321012-10321112-103212
13-10320613-10320713-10320813-10320913-10321013-10321113-103212
PartNumber LateralizedPartNumber12.5 x 145mm13.5 x 147mm15.0 x 150mm17.5 x 155mm20.0 x 160mm22.5 x 165mm25.0 x 170mm
Description
ReducedDistalTaperloc®Hip
103202103203103204103205103206103207103208103209103210103211103212
11-10320211-10320311-10320411-10320511-10320611-10320711-10320811-10320911-10321011-10321111-103212
PartNumber LateralizedPartNumber7.5 x 135mm9.0 x 137mm
10.0 x 140mm11.0 x 142mm12.5 x 145mm13.5 x 147mm15.0 x 150mm17.5 x 155mm20.0 x 160mm22.5 x 165mm25.0 x 170mm
Description
ModularPorousTaperloc®Hip