tanker operations long laneway – 1 st arriving pumper p-1 fire bldg house?= 38mm x2 + 65mm backup...
TRANSCRIPT
TANKER OPERATIONS
Long Laneway – 1st arriving pumper
P-1
FIREBLDG
House?= 38mm x2 + 65mm backup line
Barn? = consider 2- 65mm right away
Lay a Hi-Vol from the road
Good location for I/C, Acct. & Entry Control?
Another good location for I/C, Acct. & Entry Control?
TANKER OPERATIONS
Long Laneway – 1st arriving tanker
P-1
FIREBLDG
T-1If 1st Tanker arrives prior to a pumper, hook up to hi vol using 65mm female to stortz adapter then pump to P-1.
TANKER OPERATIONS
Long Laneway – 2nd arriving pumper
P-1
FIREBLDG
P-22nd arriving pumper, hook up to hi vol and pump to P-1.
(Wherever possible pump operators should maintain some water in the on board tank)
TANKER OPERATIONS
Long Laneway – 1st arriving tanker with 2nd arriving pumper
P-1
FIREBLDG
P-2
ASAP we should have a supply pumper in place to feed the attack pumper P-1 via hi vol at a long laneway rural fire
1st tanker has arrived and has set up a 65mm to pump to supply pumper P-2(All drivers need to assist each other throughout the event)
P-2
T-1
TANKER OPERATIONS
Long Laneway – 1st arriving tanker with 2nd arriving pumper
P-1
FIREBLDG
P-21st arriving tanker and all available drivers, set up porta-tank and dump while continuing 65mm pumping
T-1
All available drivers assist P-2 with set up 4” hard suction with draw down strainer.Set up 3” hard suction as well to supplement intake
TANKER OPERATIONS
P-1
FIREBLDG
P-2
T-1
Tanker 2 has arrived, pumped to P-2 and set up porta-tank and dump
Drivers, take assembled (from top of tanker) 6” hard suction with draw down strainer and 38mmredskin and place from tank to tank connecting redskin to P-2 outlet.
Long Laneway – 2nd arriving tanker with 2nd arriving pumper
Flow redskin at 550 to 700 kpa (80 to 100 psi) dependant on desired speed of transfer)
T-2
TANKER OPERATIONS
P-1
FIREBLDG
P-2
T-3
Tanker 3 has arrived and is pumping to P-2, set up porta-tank and dump
Drivers, take assembled (from top of tanker) 4” hard suction with draw down strainer and 38mmredskin and place from tank to original tank connecting redskin to P-2 outlet.
Long Laneway – 3rd arriving tanker with 2nd arriving pumper
AT THE HYDRANT
As soon as possible 3rd arriving Pumper (3) should leave his Firefighters at the fire scene and attend at the tanker fill location, whether it is a hydrant or a static source, pond steam etc.
P-3
P-3, ensure the hydrant is flushed and attach a minimum of 1 hi-vol and 2- 65’s from hydrant to truck intakes. (Certainly a hi-vol can be used in place of a 65)
Tanker Drivers assist
AT THE HYDRANT
Setting this up and pulling water from the system, diverting to tankers through your pump will greatly decrease tanker fill time, especially on a weaker hydrant.
P-3
Next, apply 2 lengths of hi-vol, 1 to each discharge of your choice – you may need 2 – 65mm female to stortz adapters, one from P-3 and one from a tanker
Tanker Drivers assistT-1
T-2Tankers have 50’ hi-vol on board
1st arriving Pumper – only feasible where Pumper can park safely within 10-15 ft of water source
AT A STATIC SOURCE (POND, STREAM ETC.) - OPTION 1
P-1
T-1
4” Hard Suction with screen on inlet with 4” hi-vol on discharge to tanker
1st arriving Pumper – only feasible where Pumper can park safely within 10-15 ft of water source
AT A STATIC SOURCE (POND, STREAM ETC.) - OPTION 1
P-1
T-1
Additionally, attach 3” hard suction with screen to 2nd inlet with an additional 65mm soft line to a 2nd discharge
T-2
AT A STATIC SOURCE (POND, STREAM ETC.) - OPTION 2
1st in Tanker
T-1 set up portable pump, hard suction, screen and bucket feeding 65mm soft line to tanker.(be advised Stn 1’s T-1 has a stortz to triple 65mm gated manifold (inset) – as soon as T-1 arrives it should insert this piece of equipment into the system–A-1 also has this item in inventory)
T-1
manifold
Drop your jerry can too
Jerry can
AT A STATIC SOURCE (POND, STREAM ETC.) - OPTION 2
1st in Tanker
Once the manifold has arrived, the feed line from the manifold to the tanker will be a length of hi-vol (don’t forget to open the gate on the pump side of the manifold)
T-1
AT A STATIC SOURCE (POND, STREAM ETC.) - OPTION 2
2nd arriving tanker
T-2 set up 2nd portable pump, hard suction screen and bucket to 2nd manifold intake – fill time now cut in half
T-2
Drop your jerry can too