This document is issued by means of a computerized syste The digitally stored original is ele ctronically approved approved document has a date entered in the `Approved'-f A manual signature is not required. The information contained in this document has to kept strictly confidential. Any unautorized use, reproduction, distribution or disclosure to third parties are strictly forbidden. ABB reservs all rights regarding Intellectual Property Rights. © Copyright 2013 ABB. All rights reserved. 6917 028-PA(A4)Rev1 255 27 30 50 D 470 111 205 C 740 710 220 220 98 6 519 A B 45 39 C/L Top flange 80 332 60 C/L Diverter switch 30 24x 15 E 289 110 55 C/L Tap selector INSULATION380 1050 SHORT VERSION b) LEVEL kV 650 380,650 750 750 1050 A1711 a)2011 a)1491 a)1791 a) Dimen- sions in mm B 1192 a)1492 a)972 a)1272 a) C 119 a)c) 119 a) 119 a)c) 119 a) D 240 c) 540 240 c) 540 Positions E 8-13 18 14-15 56 (2) 1ZSC004912-AAD No. Shts. Document no. 1 8-15 Pos A Sheet no. Order Revision 82 (1 Phase),E,T XXXX/450-600/C 2015-02-15 Swen Mattsson Language Used in product Approved by Tap-Changer VUCGRB 2015-02-15 Balamurugan N Take over department Modified by PPCO/TK 2015-02-09 Praveenkumar B Title Responsible department Prepared Same potential as the diverter switch terminal Shielding rings for insulation levels 650, 750 and 1050 only Only for insulation level 1050 kV Transformer flange H-1,3..17 Lower ring not for short version a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1) b) Short version means reduced switching capac Please refer to Technical Guide c) Not applicable for 380 kV Contact 10 at 8-9 pos. Contact 14 at 10-13 pos. Contact 18 at 14-15 pos. Only for insulation level 650, 750 and 1050 kV 21,22 20 V-2,4..18

Upload: others

Post on 16-Jul-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Tap-Changer VUCGRB Balamurugan N Approved by …...Balamurugan N 2015-02-15 Modified by Take over department Praveenkumar B 2015-02-09 PPCO/TK Prepared Responsible department Title

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2013 ABB. All rights reserved.

6917 028-PA(A4)Rev1

255

27

30

50

D470

111 205

C

740

710

220 220

98

6

519

A

B

4539

C/L Top flange80

332

60

C/L Diverter switch30

24x 15

E

289

110

55

C/L Tap selector

INSULATION380 1050 SHORT VERSION b)LEVEL kV 650 380,650

750 750 1050

A 1711 a)2011 a)1491 a)1791 a)Dimen-sionsin mm

B 1192 a)1492 a)972 a) 1272 a)

C 119 a)c)119 a) 119 a)c)119 a)

D 240 c) 540 240 c) 540

Positions E

8-13 18

14-15 56

(2)1ZSC004912-AADNo. Shts.Document no.

18-15 PosA

Sheet no.OrderRevision

82 (1 Phase),E,T XXXX/450-600/C2015-02-15Swen Mattsson

LanguageUsed in productApproved by

Tap-Changer VUCGRB2015-02-15Balamurugan N

Take over departmentModified by

PPCO/TK2015-02-09Praveenkumar B

TitleResponsible departmentPrepared

Same potential as thediverter switch terminal

Shielding rings forinsulation levels 650,750 and 1050 only

Only for insulation level 1050 kV

Transformer flange

H-1,3..17

Lower ring not for short version

a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)b) Short version means reduced switching capacity.Please refer to Technical Guidec) Not applicable for 380 kV

Contact 10 at 8-9 pos.Contact 14 at 10-13 pos.Contact 18 at 14-15 pos.

Only for insulation level 650, 750 and 1050 kV

21,2220

V-2,4..18

Page 2: Tap-Changer VUCGRB Balamurugan N Approved by …...Balamurugan N 2015-02-15 Modified by Take over department Praveenkumar B 2015-02-09 PPCO/TK Prepared Responsible department Title

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2013 ABB. All rights reserved.

6917 028-PA(A4)Rev1

R200

36�$�

72�$�

36�$�

20�$�

40�$�

20�$� 20�$�

86

232

41

86

41

100

25,7�$�

25,7�$�

25,7�$�

22

10

11

26

48�$�

84�$�

R200

51,5�$�

20�$�

ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide VUCMounting on active part: 54920103-1Accessories:54920103-2Motor Drive BUL:54830001-1Motor Drive BUE:54830001-2 or -3External Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1

(2)1ZSC004912-AADNo. Shts.Document no.

28-15 PosA

Sheet no.OrderRevision

82 (1 Phase),E,T XXXX/450-600/C2015-02-15Swen Mattsson

LanguageUsed in productApproved by

Tap-Changer VUCGRB2015-02-15Balamurugan N

Take over departmentModified by

PPCO/TK2015-02-09Praveenkumar B

TitleResponsible departmentPrepared

29

8-9 positions

Current collector

Current collector

P-P0,075

83

205

61

49 2

7

10 21

22

R240

10-13 positions

P-P0,075

81

103

411

613

125

207

22

2114

14-15 positions

AP-P

0,075

123

145

167

209

211

413

615

101

817 18 21

22A T=9