target mainly by t. nakadaira, y. hayato, a.k.ichikawa
DESCRIPTION
Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa. Here, I will report about the present status on target R&D. Current main member around target. Construction group leader T. Kobayashi Convener of target and horn system : A.K.Ichikawa Convener of target station : Y. Yamada - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/1.jpg)
Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa
Here, I will report about the present status on target R&D.
![Page 2: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/2.jpg)
Current main member around target
Construction group leader T. Kobayashi
Convener of target and horn system : A.K.Ichikawa
Convener of target station : Y. Yamada
Target design : T. Nakadaira et. al
Target FEM calculation : Y. Hayato et. al
Radiation damage study : Y. Hayato et. al
International collaboration
Horn, especially on 2nd horn with E.Zimmerman and L.Bartoszek
Target : start discussion with RAL
![Page 3: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/3.jpg)
Thermal Stress
J/gK degree
Z
RTemperature rise of the target due to the radiation
w/ 1 pulse
cal. w/ MARS
2.6MJ in 5sAluminum cannot withstand.Only low-Z material such as graphite or beryllium.
Thermal stress 6.8 MPa
(safety factor ~3 against fatigue strength)
![Page 4: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/4.jpg)
Water cooling
Water Temp. 25oCHeat transfer rate 5kW/m2K confirmed by cooling testFlow rate 20 l/min
![Page 5: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/5.jpg)
Case(container)
Target(Graphite)
Gap
IG-110 @400oC 2dpa -> -0.5%
Effect of irradiation
@ J-PARC
0.26dpa/year
![Page 6: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/6.jpg)
Effect of irradiation on graphite
Damage by neutron irradiation 0.25dpa@200oC … Change of dimension +0.14% Thermal conductivity -98%0.13dpa@300oC … … Change of dimension -0.01% Thermal conductivity -75%
![Page 7: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/7.jpg)
Coaxial cooling pipe : Ti or Graphite
![Page 8: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/8.jpg)
Time evolution of temperature(assuming specific heat at constant pressure)
780℃
660℃~430℃~620℃
380℃25℃
~80℃
Condition (example)
~600W/m2K @~1atm. flow velocity 170m/s
![Page 9: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/9.jpg)
Prototype design of Target system
Prototype design for He cooling pipe is in progress.
Entrance of He
Exit of He
graphite Target
Graphite Cap
Inner Pipe t=2.0mm Graphite
or t=0.3mm Ti (Ti-6Al-4V)
Outer Pipe t=0.3mm Ti-6Al-4V
![Page 10: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/10.jpg)
![Page 11: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/11.jpg)
baffle
FVD2
![Page 12: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/12.jpg)
Temperature rise with nominal beam
理想的なバッフル ターゲット外径
= バッフル内径 水冷の場合
配管 Al 0.8mm
![Page 13: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/13.jpg)
Temperature rise with mis-directed beam
![Page 14: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/14.jpg)
Baffle –other possibility-
![Page 15: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/15.jpg)
![Page 16: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/16.jpg)
One of the Concept of Horn support
第3ホーン形状図
Rod for position measurement
Adjusting bolt
Adjusting bolt
vertical alignment rods
frame A(fixed)
frame B(verticalmotion)
frame C(horizontal
motion)
xy-stage
by S.Koike
![Page 17: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/17.jpg)
Another Concept of Horn support
~4m
~1m
~1.5m くらいか
支持基準
支持基準を 100mで調整できれば、~1mm は達成できる?
![Page 18: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/18.jpg)
Other R&D items -Remote Maintenance-
Side View
Top View
Disconnect Horn and it’s support structure including strip-lines.
Is this realistic?
Residual radiation level should be checked.
Anyway, we need remotely connectable/dis-connectable cuppling
For strip-lines and water pipes.
![Page 19: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/19.jpg)
comments
The target is a critical part of the project and the relation to the 1st horn is rather complicated.
I feel that careful discussion is necessary before the real collaboration on the target to make clear situation.
![Page 20: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/20.jpg)
Supplement
![Page 21: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/21.jpg)
Target Nu-TAC 以後の進展Graphite の熱応力の再評価 (S. Ueda)
比熱の温度依存性の update & bug fix
等価応力[MPa] 安全率
東洋炭素 IG-43 7.48 4.0
東海カーボン G-347 5.55 4.5
等価応力[MPa] 安全率
7.42 3.51
6.45 3.41
安全率3 は満たされている。 東洋炭素 ISO-88 についても安全率を評価
等価応力[MPa]
引張強度[MPa]
安全率
東洋炭素 ISO-88 11.24 68.6 4.27
![Page 22: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/22.jpg)
内側配管の温度勾配 / 応力分布Al 合金 (0.8mm 厚 ),Ti 合金 (0.3mm 厚 )
~200℃
動径方向応力<10kPa
円周方向応力< 2M Pa
軸方向応力< 4M Pa
等価応力 < 3M Pa 安全率
横軸 : 0= 最内面1= 最外面
![Page 23: Target mainly by T. Nakadaira, Y. Hayato, A.K.Ichikawa](https://reader035.vdocuments.net/reader035/viewer/2022062720/5681350e550346895d9c6333/html5/thumbnails/23.jpg)
He冷却管のプロトタイプの設計He の流量、除熱能力を試験したい。KEKB/Belle の衝突点チェンバー冷却用の He
システムを使ったテストの検討中。 最大ゲージ圧 0.1MPa, He 流量 400 [l/min] カウンターホール
への移設可• 電源 : 200V15A• 冷却水 10-50[l/min]
冷却配管を設計中絶縁材の材質を検討中